1.
Neuroimage ; 148: 352-363, 2017 03 01.
Article in English | MEDLINE | ID: mdl-28088482

ABSTRACT

This study investigated lag structure in the resting-state fMRI by applying a novel independent component (ICA) method to magnetic resonance encephalography (MREG) data. Briefly, the spatial ICA (sICA) was used for defining the frontal and back nodes of the default mode network (DMN), and the temporal ICA (tICA), which is enabled by the high temporal resolution of MREG (TR=100ms), was used to separate both neuronal and physiological components of these two spatial map regions. Subsequently, lag structure was investigated between the frontal (DMNvmpf) and posterior (DMNpcc) DMN nodes using both conventional method with all-time points and a sliding-window approach. A rigorous noise exclusion criterion was applied for tICs to remove physiological pulsations, motion and system artefacts. All the de-noised tICs were used to calculate the null-distributions both for expected lag variability over time and over subjects. Lag analysis was done for the three highest correlating denoised tICA pairs. Mean time lag of 0.6s (± 0.5 std) and mean absolute correlation of 0.69 (± 0.08) between the highest correlating tICA pairs of DMN nodes was observed throughout the whole analyzed period. In dynamic 2min window analysis, there was large variability over subjects as ranging between 1-10sec. Directionality varied between these highly correlating sources an average 28.8% of the possible number of direction changes. The null models show highly consistent correlation and lag structure between DMN nodes both in continuous and dynamic analysis. The mean time lag of a null-model over time between all denoised DMN nodes was 0.0s and, thus the probability of having either DMNpcc or DMNvmpf as a preceding component is near equal. All the lag values of highest correlating tICA pairs over subjects lie within the standard deviation range of a null-model in whole time window analysis, supporting the earlier findings that there is a consistent temporal lag structure across groups of individuals. However, in dynamic analysis, there are lag values exceeding the threshold of significance of a null-model meaning that there might be biologically meaningful variation in this measure. Taken together the variability in lag and the presence of high activity peaks during strong connectivity indicate that individual avalanches may play an important role in defining dynamic independence in resting state connectivity within networks.


Subject(s)
Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Adult , Algorithms , Artifacts , Brain Mapping , Electroencephalography , Female , Humans , Individuality , Male , Multimodal Imaging , Nerve Net/diagnostic imaging , Neural Pathways/diagnostic imaging , Neural Pathways/physiology , Principal Component Analysis , Spectroscopy, Near-Infrared , Young Adult
2.
Front Neurosci ; 13: 279, 2019.
Article in English | MEDLINE | ID: mdl-31001071

ABSTRACT

Low image sampling rates used in resting state functional magnetic resonance imaging (rs-fMRI) may cause aliasing of the cardiorespiratory pulsations over the very low frequency (VLF) BOLD signal fluctuations which reflects to functional connectivity (FC). In this study, we examine the effect of sampling rate on currently used rs-fMRI FC metrics. Ultra-fast fMRI magnetic resonance encephalography (MREG) data, sampled with TR 0.1 s, was downsampled to different subsampled repetition times (sTR, range 0.3-3 s) for comparisons. Echo planar k-space sampling (TR 2.15 s) and interleaved slice collection schemes were also compared against the 3D single shot trajectory at 2.2 s sTR. The quantified connectivity metrics included stationary spatial, time, and frequency domains, as well as dynamic analyses. Time domain methods included analyses of seed-based functional connectivity, regional homogeneity (ReHo), coefficient of variation, and spatial domain group level probabilistic independent component analysis (ICA). In frequency domain analyses, we examined fractional and amplitude of low frequency fluctuations. Aliasing effects were spatially and spectrally analyzed by comparing VLF (0.01-0.1 Hz), respiratory (0.12-0.35 Hz) and cardiac power (0.9-1.3 Hz) FFT maps at different sTRs. Quasi-periodic pattern (QPP) of VLF events were analyzed for effects on dynamic FC methods. The results in conventional time and spatial domain analyses remained virtually unchanged by the different sampling rates. In frequency domain, the aliasing occurred mainly in higher sTR (1-2 s) where cardiac power aliases over respiratory power. The VLF power maps suffered minimally from increasing sTRs. Interleaved data reconstruction induced lower ReHo compared to 3D sampling (p < 0.001). Gradient recalled echo-planar imaging (EPI BOLD) data produced both better and worse metrics. In QPP analyses, the repeatability of the VLF pulse detection becomes linearly reduced with increasing sTR. In conclusion, the conventional resting state metrics (e.g., FC, ICA) were not markedly affected by different TRs (0.1-3 s). However, cardiorespiratory signals showed strongest aliasing in central brain regions in sTR 1-2 s. Pulsatile QPP and other dynamic analyses benefit linearly from short TR scanning.

3.
J Cereb Blood Flow Metab ; 39(12): 2471-2485, 2019 12.
Article in English | MEDLINE | ID: mdl-30204040

ABSTRACT

Ultra-fast functional magnetic resonance encephalography (MREG) enables separate assessment of cardiovascular, respiratory, and vasomotor waves from brain pulsations without temporal aliasing. We examined effects of breath hold- (BH) related changes on cardiovascular brain pulsations using MREG to study the physiological nature of cerebrovascular reactivity. We used alternating 32 s BH and 88 s resting normoventilation (NV) to change brain pulsations during MREG combined with simultaneously measured respiration, continuous non-invasive blood pressure, and cortical near-infrared spectroscopy (NIRS) in healthy volunteers. Changes in classical resting-state network BOLD-like signal and cortical blood oxygenation were reproduced based on MREG and NIRS signals. Cardiovascular pulsation amplitudes of MREG signal from anterior cerebral artery, oxygenated hemoglobin concentration in frontal cortex, and blood pressure decreased after BH. MREG cardiovascular pulse amplitudes in cortical areas and sagittal sinus increased, while cerebrospinal fluid and white matter remained unchanged. Respiratory centers in the brainstem - hypothalamus - thalamus - amygdala network showed strongest increases in cardiovascular pulsation amplitude. The spatial propagation of averaged cardiovascular impulses altered as a function of successive BH runs. The spread of cardiovascular pulse cycles exhibited a decreasing spatial similarity over time. MREG portrayed spatiotemporally accurate respiratory network activity and cardiovascular pulsation dynamics related to BH challenges at an unpreceded high temporal resolution.


Subject(s)
Breath Holding , Cerebrovascular Circulation , Magnetic Resonance Angiography , Pulsatile Flow , Respiratory Center , Adult , Female , Humans , Male , Respiratory Center/blood supply , Respiratory Center/diagnostic imaging
4.
Brain Behav ; 8(9): e01090, 2018 09.
Article in English | MEDLINE | ID: mdl-30112813

ABSTRACT

INTRODUCTION: Functional magnetic resonance imaging (fMRI) combined with simultaneous electroencephalography (EEG-fMRI) has become a major tool in mapping epilepsy sources. In the absence of detectable epileptiform activity, the resting state fMRI may still detect changes in the blood oxygen level-dependent signal, suggesting intrinsic alterations in the underlying brain physiology. METHODS: In this study, we used coefficient of variation (CV) of critically sampled 10 Hz ultra-fast fMRI (magnetoencephalography, MREG) signal to compare physiological variance between healthy controls (n = 10) and patients (n = 10) with drug-resistant epilepsy (DRE). RESULTS: We showed highly significant voxel-level (p < 0.01, TFCE-corrected) increase in the physiological variance in DRE patients. At individual level, the elevations range over three standard deviations (σ) above the control mean (µ) CVMREG values solely in DRE patients, enabling patient-specific mapping of elevated physiological variance. The most apparent differences in group-level analysis are found on white matter, brainstem, and cerebellum. Respiratory (0.12-0.4 Hz) and very-low-frequency (VLF = 0.009-0.1 Hz) signal variances were most affected. CONCLUSIONS: The CVMREG increase was not explained by head motion or physiological cardiorespiratory activity, that is, it seems to be linked to intrinsic physiological pulsations. We suggest that intrinsic brain pulsations play a role in DRE and that critically sampled fMRI may provide a powerful tool for their identification.


Subject(s)
Brain Mapping/methods , Brain/physiopathology , Drug Resistant Epilepsy/physiopathology , Electroencephalography/methods , Magnetic Resonance Imaging/methods , Adult , Female , Humans , Magnetoencephalography/methods , Male