Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38900308

ABSTRACT

To meet the growing demand for intraoperative molecular imaging, the development of compatible imaging agents plays a crucial role. Given the unique requirements of surgical applications compared to diagnostics and therapy, maximizing translational potential necessitates distinctive imaging agent designs. For effective surgical guidance, exogenous signatures are essential and are achievable through a diverse range of imaging labels such as (radio)isotopes, fluorescent dyes, or combinations thereof. To achieve optimal in vivo utility a balanced molecular design of the tracer as a whole is required, which ensures a harmonious effect of the imaging label with the affinity and specificity (e.g., pharmacokinetics) of a pharmacophore/targeting moiety. This review outlines common design strategies and the effects of refinements in the molecular imaging agent design on the agent's pharmacological profile. This includes the optimization of affinity, pharmacokinetics (including serum binding and target mediated background), biological clearance route, the achievable signal intensity, and the effect of dosing hereon.

2.
Article in English | MEDLINE | ID: mdl-38233609

ABSTRACT

PURPOSE: The aim of this review is to give an overview of the current status of molecular image-guided surgery in gynaecological malignancies, from both clinical and technological points of view. METHODS: A narrative approach was taken to describe the relevant literature, focusing on clinical applications of molecular image-guided surgery in gynaecology, preoperative imaging as surgical roadmap, and intraoperative devices. RESULTS: The most common clinical application in gynaecology is sentinel node biopsy (SNB). Other promising approaches are receptor-target modalities and occult lesion localisation. Preoperative SPECT/CT and PET/CT permit a roadmap for adequate surgical planning. Intraoperative detection modalities span from 1D probes to 2D portable cameras and 3D freehand imaging. CONCLUSION: After successful application of radio-guided SNB and SPECT, innovation is leaning towards hybrid modalities, such as hybrid tracer and fusion of imaging approaches including SPECT/CT and PET/CT. Robotic surgery, as well as augmented reality and virtual reality techniques, is leading to application of these innovative technologies to the clinical setting, guiding surgeons towards a precise, personalised, and minimally invasive approach.

3.
Eur J Nucl Med Mol Imaging ; 51(7): 2085-2097, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38329507

ABSTRACT

PURPOSE: The aim of this study was to investigate the biodistribution of (super-)selective trans-arterial radioembolization (TARE) with holmium-166 microspheres (166Ho-MS), when administered as adjuvant therapy after RFA of HCC 2-5 cm. The objective was to establish a treatment volume absorbed dose that results in an absorbed dose of ≥ 120 Gy on the hyperemic zone around the ablation necrosis (i.e., target volume). METHODS: In this multicenter, prospective dose-escalation study in BCLC early stage HCC patients with lesions 2-5 cm, RFA was followed by (super-)selective infusion of 166Ho-MS on day 5-10 after RFA. Dose distribution within the treatment volume was based on SPECT-CT. Cohorts of up to 10 patients were treated with an incremental dose (60 Gy, 90 Gy, 120 Gy) of 166Ho-MS to the treatment volume. The primary endpoint was to obtain a target volume dose of ≥ 120 Gy in 9/10 patients within a cohort. RESULTS: Twelve patients were treated (male 10; median age, 66.5 years (IQR, [64.3-71.7])) with a median tumor diameter of 2.7 cm (IQR, [2.1-4.0]). At a treatment volume absorbed dose of 90 Gy, the primary endpoint was met with a median absorbed target volume dose of 138 Gy (IQR, [127-145]). No local recurrences were found within 1-year follow-up. CONCLUSION: Adjuvant (super-)selective infusion of 166Ho-MS after RFA for the treatment of HCC can be administered safely at a dose of 90 Gy to the treatment volume while reaching a dose of ≥ 120 Gy to the target volume and may be a favorable adjuvant therapy for HCC lesions 2-5 cm. TRIAL REGISTRATION: Clinicaltrials.gov NCT03437382 . (registered: 19-02-2018).


Subject(s)
Carcinoma, Hepatocellular , Embolization, Therapeutic , Holmium , Liver Neoplasms , Radioisotopes , Humans , Carcinoma, Hepatocellular/radiotherapy , Carcinoma, Hepatocellular/therapy , Carcinoma, Hepatocellular/diagnostic imaging , Liver Neoplasms/radiotherapy , Liver Neoplasms/therapy , Male , Holmium/therapeutic use , Female , Aged , Middle Aged , Embolization, Therapeutic/methods , Radioisotopes/therapeutic use , Radioisotopes/administration & dosage , Radiofrequency Ablation/methods , Radiotherapy Dosage , Neoplasm Staging , Tissue Distribution
4.
HPB (Oxford) ; 26(7): 919-927, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38604828

ABSTRACT

INTRODUCTION: This study investigates the incidence of extrahepatic perfusion and incomplete hepatic perfusion at intraoperative methylene blue testing and on postoperative nuclear imaging in patients undergoing hepatic arterial infusion pump (HAIP) chemotherapy. METHODS: The first 150 consecutive patients who underwent pump implantation in the Netherlands were included. All patients underwent surgical pump implantation with the catheter in the gastroduodenal artery. All patients underwent intraoperative methylene blue testing and postoperative nuclear imaging (99mTc-Macroaggregated albumin SPECT/CT) to determine perfusion via the pump. RESULTS: Patients were included between January-2018 and December-2021 across eight centers. During methylene blue testing, 29.3% had extrahepatic perfusion, all successfully managed intraoperatively. On nuclear imaging, no clinically relevant extrahepatic perfusion was detected (0%, 95%CI: 0.0-2.5%). During methylene blue testing, 2.0% had unresolved incomplete hepatic perfusion. On postoperative nuclear imaging, 8.1% had incomplete hepatic perfusion, leading to embolization in only 1.3%. CONCLUSION: Methylene blue testing during pump placement for intra-arterial chemotherapy identified extrahepatic perfusion in 29.3% of patients, but could be resolved intraoperatively in all patients. Postoperative nuclear imaging found no clinically relevant extrahepatic perfusion and led to embolization in only 1.3% of patients. The role of routine nuclear imaging after HAIP implantation should be studied in a larger cohort.


Subject(s)
Hepatic Artery , Infusions, Intra-Arterial , Humans , Male , Female , Middle Aged , Aged , Netherlands/epidemiology , Hepatic Artery/diagnostic imaging , Methylene Blue/administration & dosage , Incidence , Liver Neoplasms/surgery , Single Photon Emission Computed Tomography Computed Tomography , Retrospective Studies , Liver Circulation , Infusion Pumps, Implantable , Antineoplastic Agents/administration & dosage , Technetium Tc 99m Aggregated Albumin/administration & dosage
5.
Article in English | MEDLINE | ID: mdl-38030743

ABSTRACT

BACKGROUND: The current expansion of image-guided surgery is closely related to the role played by radio-guided surgery in supporting the sentinel node (SN) procedure during more than three decades. The so-called triple approach (lymphoscintigraphy, gamma probe detection and blue dye) was not only essential in the seminal validation of the SN procedure but also a first collective learning effort based on skill transfer and outcome-related evaluation which laid the fundaments to delineate the field of intraoperative molecular imaging (IMI) based on a similar multimodality approach and multidisciplinary practice. METHODS: These elements are also becoming valid in the current incorporation of SPECT/CT and PET/CT to existing and new protocols of IMI procedures and SN mapping concerning other clinical applications. On the other hand, there is a growing tendency to combine novel modern technologies in an allied role with gamma guidance in the operating room following the development of hybrid tracers and multimodal detection approaches. Against this background, learning initiatives are required for professionals working in this area. RESULTS: This objective has led to a group of European practitioners with large experience in SN mapping and IMI applications to give shape to a programme made up out of specific learning modules aimed to be used as a conductive thread in peripherical or centralised training instances concerning the topic. CONCLUSION: The presented work, written as a tutorial review, is placed in an available prior-art context and is primarily aimed at medical and paramedical practitioners as well as at hardware and software developers.

6.
Eur J Nucl Med Mol Imaging ; 50(8): 2282-2291, 2023 07.
Article in English | MEDLINE | ID: mdl-36929210

ABSTRACT

BACKGROUND: Lymph node (LN) metastasis is a relevant predictor for survival in patients with a.o. penile cancer (PeCa), malignant melanoma. The sentinel node (SN) procedure comprises targeted resection of the first tumour-draining SNs. Here, the hybrid tracer indocyanine green (ICG)-99mTc-nanocolloid has been used for several years to combine optical and nuclear detection. Recently, the resource of the nanocolloid precursor stopped production and the precursor was replaced by a different but chemically comparable colloid, nanoscan. Our aim was to study the performance of ICG-99mTc-nanoscan compared to ICG-99mTc-nanocolloid from a nuclear and surgical perspective. METHODS: Twenty-four patients with either PeCa or head-and-neck (H&N) melanoma and scheduled for a SN procedure were included. The initial group (n = 11) received ICG-99mTc-nanocolloid until no longer available; the second group (n = 13) received ICG-99mTc-nanoscan. Tracer uptake was assessed on lymphoscintigraphy and single-photon emission (SPECT). Intraoperatively, SNs were identified using gamma tracing and fluorescence imaging. Ex vivo (back-table) measurements were conducted to quantify the fluorescence emissions. Chemical analysis was performed to compare the ICG assembly on both precursors. RESULTS: The mean tracer uptake in the SNs was similar for ICG-99mTc-nanocolloid (2.2 ± 4.3%ID) and ICG-99mTc-nanoscan (1.8 ± 2.6%ID; p = 0.68). 3 SNs (interquartile range (IQR) 3-4) were detected on lymphoscintigraphy in PeCa patients receiving ICG-99mTc-nanoscan compared to 2 SNs (IQR 2-3) in PeCa patients receiving ICG-99mTc-nanocolloid (p = 0.045), no differences were observed in H&N patients. Back-table measurements of resected SNs revealed a lower total fluorescence intensity in the ICG-99mTc-nanoscan group (24*109 arbitrary units (A.U) IQR 1.6*109-14*109 in the ICG-99mTc-nanocolloid group versus 4.6*109 A.U. IQR 2.4*109-42*109 in the ICG-99mTc-nanoscan group, p = 0.0054). This was consistent with a larger degree of "stacked" ICG observed in the nanoscan formulation. No tracer-related adverse events were reported. CONCLUSIONS: Based on this retrospective analysis, we can conclude that ICG-99mTc-nanoscan has similar capacity for SN identification as ICG-99mTc-nanocolloid and can safely be implemented in SN procedures.


Subject(s)
Melanoma , Nuclear Medicine , Penile Neoplasms , Sentinel Lymph Node , Male , Humans , Indocyanine Green , Sentinel Lymph Node Biopsy/methods , Retrospective Studies , Sentinel Lymph Node/surgery , Melanoma/diagnostic imaging , Melanoma/surgery , Melanoma/pathology , Radiopharmaceuticals , Lymphatic Metastasis , Penile Neoplasms/pathology , Technetium Tc 99m Aggregated Albumin
7.
Article in English | MEDLINE | ID: mdl-38012448

ABSTRACT

PURPOSE: Prostate-specific membrane antigen (PSMA) is increasingly considered as a molecular target to achieve precision surgery for prostate cancer. A Delphi consensus was conducted to explore expert views in this emerging field and to identify knowledge and evidence gaps as well as unmet research needs that may help change practice and improve oncological outcomes for patients. METHODS: One hundred and five statements (scored by a 9-point Likert scale) were distributed through SurveyMonkey®. Following evaluation, a consecutive second round was performed to evaluate consensus (16 statements; 89% response rate). Consensus was defined using the disagreement index, assessed by the research and development project/University of California, Los Angeles appropriateness method. RESULTS: Eighty-six panel participants (72.1% clinician, 8.1% industry, 15.1% scientists, and 4.7% other) participated, most with a urological background (57.0%), followed by nuclear medicine (22.1%). Consensus was obtained on the following: (1) The diagnostic PSMA-ligand PET/CT should ideally be taken < 1 month before surgery, 1-3 months is acceptable; (2) a 16-20-h interval between injection of the tracer and surgery seems to be preferred; (3) PSMA targeting is most valuable for identification of nodal metastases; (4) gamma, fluorescence, and hybrid imaging are the preferred guidance technologies; and (5) randomized controlled clinical trials are required to define oncological value. Regarding surgical margin assessment, the view on the value of PSMA-targeted surgery was neutral or inconclusive. A high rate of "cannot answer" responses indicates further study is necessary to address knowledge gaps (e.g., Cerenkov or beta-emissions). CONCLUSIONS: This Delphi consensus provides guidance for clinicians and researchers that implement or develop PSMA-targeted surgery technologies. Ultimately, however, the consensus should be backed by randomized clinical trial data before it may be implemented within the guidelines.

8.
Gynecol Oncol ; 159(3): 672-680, 2020 12.
Article in English | MEDLINE | ID: mdl-33041071

ABSTRACT

OBJECTIVE: The aim of this study was to assess the superiority of ICG-99mTc-nanocolloid for the intraoperative visual detection of sentinel lymph nodes (SLNs) in vulvar squamous cell carcinoma (VSCC) patients compared to standard SLN detection using 99mTc-nanocolloid with blue dye. METHODS: In this multicenter, randomized controlled trial, VSCC patients underwent either the standard SLN procedure or with the hybrid tracer ICG-99mTc-nanocolloid. The primary endpoint was the percentage of fluorescent SLNs compared to blue SLNs. Secondary endpoints were successful SLN procedures, surgical outcomes and postoperative complications. RESULTS: Forty-eight patients were randomized to the standard (n = 24) or fluorescence imaging group (n = 24) using ICG-99mTc-nanocolloid. The percentage of blue SLNs was 65.3% compared to 92.5% fluorescent SLNs (p < 0.001). A successful SLN procedure was obtained in 92.1% of the groins in the standard group and 97.2% of the groins in the fluorescence imaging group (p = 0.33). Groups did not differ in surgical outcome, although more short-term postoperative complications were documented in the standard group (p = 0.041). CONCLUSIONS: Intraoperative visual detection of SLNs in patients with VSCC using ICG-99mTc-nanocolloid was superior compared to 99mTc-nanocolloid and blue dye. The rate of successful SLN procedures between both groups was not significantly different. Fluorescence imaging has potential to be used routinely in the SLN procedure in VSCC patients to facilitate the search by direct visualization. CLINICAL TRIAL REGISTRATION: Netherlands Trial Register (Trial ID NL7443).


Subject(s)
Carcinoma, Squamous Cell/diagnosis , Intraoperative Care/methods , Lymphatic Metastasis/diagnosis , Sentinel Lymph Node/diagnostic imaging , Vulvar Neoplasms/surgery , Adult , Aged , Aged, 80 and over , Carcinoma, Squamous Cell/secondary , Carcinoma, Squamous Cell/surgery , Coloring Agents/administration & dosage , Female , Humans , Lymph Node Excision , Lymphatic Metastasis/therapy , Middle Aged , Netherlands , Operative Time , Optical Imaging/methods , Radiopharmaceuticals/administration & dosage , Sentinel Lymph Node/pathology , Sentinel Lymph Node/surgery , Sentinel Lymph Node Biopsy/methods , Time Factors , Vulvar Neoplasms/pathology , Vulvectomy
9.
Int J Gynecol Cancer ; 25(6): 1086-93, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25768079

ABSTRACT

OBJECTIVE: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) has recently been introduced to improve the sentinel lymph node (SLN) procedure. Several optical tracers have been successfully tested. However, the optimal tracer formulation is still unknown. This study evaluates the performance of ICG-technetium-99m (99mTc)-nanocolloid in relation to 2 most commonly used ICG-based formulas during SLN biopsy in vulvar cancer. METHODS AND MATERIALS: Twelve women who planned to undergo SLN biopsy for stage I vulvar cancer were prospectively included. Sentinel lymph node mapping was performed using the dual-modality radioactive and NIR fluorescence tracer ICG-99mTc-nanocolloid. All patients underwent combined SLN localization using NIR fluorescence and the (current) gold standard using blue dye and radioactive guidance. RESULTS: In all 12 patients, at least 1 SLN was detected during surgery. A total of 21 lymph nodes (median 2; range, 1-3) were resected. Median time between skin incision and first SLN detection was 8 (range, 1-22) minutes. All resected SLNs were both radioactive and fluorescent, although only 13 (62%) of 21 SLNs stained blue. Median brightness of exposed SLNs, expressed as signal-to-background ratio, was 5.4 (range, 1.8-11.8). Lymph node metastases were found in 3 patients. CONCLUSIONS: Near-infrared fluorescence-guided SLN mapping is feasible and outperforms blue dye staining. Premixing ICG with 99mTc-nanocolloid provides real-time intraoperative imaging of the SN and seems to be the optimal tracer combination in terms of intraoperative detection rate of the SN (100%). Moreover, ICG-99mTc-nanocolloid allows the administration of a 5-times lower injected dose of ICG (compared with ICG and ICG absorbed to human serum albumin) and can be injected up to 20 hours before surgery.


Subject(s)
Image-Guided Biopsy/methods , Indocyanine Green/pharmacokinetics , Sentinel Lymph Node Biopsy , Technetium Tc 99m Aggregated Albumin/pharmacokinetics , Vulvar Neoplasms/diagnostic imaging , Vulvar Neoplasms/pathology , Adult , Aged , Aged, 80 and over , Coloring Agents/pharmacokinetics , Female , Fluorescence , Follow-Up Studies , Humans , Middle Aged , Neoplasm Staging , Prognosis , Prospective Studies , Radionuclide Imaging , Radiopharmaceuticals/pharmacokinetics , Spectroscopy, Near-Infrared , Tissue Distribution
10.
Expert Rev Med Devices ; 21(5): 349-358, 2024 May.
Article in English | MEDLINE | ID: mdl-38722051

ABSTRACT

INTRODUCTION: Surgery and biomedical imaging encompass a big share of the medical-device market. The ever-mounting demand for precision surgery has driven the integration of these two into the field of image-guided surgery. A key-question herein is how imaging modalities can guide the surgical decision-making process. Through performance-based design, chemists, engineers, and doctors need to build a bridge between imaging technologies and surgical challenges. AREAS-COVERED: This perspective article highlights the complementary nature between the technological design of an image-guidance modality and the type of procedure performed. The specific roles of the involved professionals, imaging technologies, and surgical indications are addressed. EXPERT-OPINION: Molecular-image-guided surgery has the potential to advance pre-, intra- and post-operative tissue characterization. To achieve this, surgeons need the access to well-designed indication-specific chemical-agents and detection modalities. Hereby, some technologies stimulate exploration ('go'), while others stimulate caution ('stop'). However, failing to adequately address the indication-specific needs rises the risk of incorrect tool employment and sub-optimal surgical performance. Therefore, besides the availability of new technologies, market growth is highly dependent on the practical nature and impact on real-life clinical care. While urology currently takes the lead in the widespread implementation of image-guidance technologies, the topic is generic and its popularity spreads rapidly within surgical oncology.


Subject(s)
Surgery, Computer-Assisted , Humans , Surgery, Computer-Assisted/instrumentation , Surgery, Computer-Assisted/methods , Diagnostic Imaging/methods , Diagnostic Imaging/instrumentation , Precision Medicine/methods , Precision Medicine/instrumentation , Equipment and Supplies
11.
J Nucl Med ; 65(4): 548-554, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38485277

ABSTRACT

Prostate-specific membrane antigen (PSMA) PET is used to select patients with recurrent prostate cancer for metastasis-directed therapy. A surgical approach can be achieved through radioguided surgery (RGS), using a Drop-In γ-probe that traces lesions that accumulate the radioactive signal. With the aim of guiding patient selection for salvage surgery, we studied the correlation between the SUVmax of lesions on preoperative PSMA PET/CT and their intraoperative counts/s measured using the Drop-In γ-probe. Methods: A secondary analysis based on the prospective, single-arm, and single-center feasibility study was conducted (NCT03857113). Patients (n = 29) with biochemical recurrence after previous curative-intent therapy and a maximum of 3 suggestive lesions within the pelvis on preoperative PSMA PET/CT were included. Patients treated with androgen deprivation therapy within 6 mo before surgery were excluded. All patients received an intravenous injection of 99mTc-PSMA-I&S 1 d before surgery. Radioguidance was achieved using a Drop-In γ-probe. Correlation was determined using the Spearman rank correlation coefficient (ρs). Subgroup analysis was based on the median SUVmax Results: In total, 33 lesions were visible on the PSMA PET/CT images, with a median overall SUVmax of 6.2 (interquartile range [IQR], 4.2-9.7). RGS facilitated removal of 31 lesions. The median Drop-In counts/s were 134 (IQR, 81-220) in vivo and 109 (IQR, 72-219) ex vivo. The intensity of the values correlated with SUVmax (ρs = 0.728 and 0.763, respectively; P < 0.001). Subgroup analysis based on median SUVmax in the group with an SUVmax of less than 6 showed no statistically significant correlation with the numeric signal in vivo (ρs = 0.382; P = 0.221) or the signal-to-background-ratio (ρs = 0.245; P = 0.442), whereas the group with an SUVmax of 6 or more showed respective statistically significant positive correlations (ρs = 0.774 [P < 0.001] and ρs = 0.647 [P = 0.007]). Conclusion: Our findings indicate that there is a direct relation between SUVmax on PSMA PET/CT and the readout recorded by the surgical Drop-In probe, thereby indicating that SUVmax can be used to select patients for PSMA RGS. For more definitive subgroup definitions for treatment recommendations, further studies are necessary to validate the present findings.


Subject(s)
Prostatic Neoplasms , Male , Humans , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Prostatic Neoplasms/pathology , Positron Emission Tomography Computed Tomography/methods , Androgen Antagonists , Prospective Studies , Neoplasm Recurrence, Local/pathology , Gallium Radioisotopes
12.
J Clin Med ; 12(3)2023 Jan 24.
Article in English | MEDLINE | ID: mdl-36769566

ABSTRACT

The targeted delivery of anti-cancer drugs and isotopes is one of the most pursued goals in anti-cancer therapy. One of the prime examples of such an application is the intra-arterial injection of microspheres containing cytostatic drugs or radioisotopes during hepatic embolization procedures. Therapy based on the application of microspheres revolves around vascular occlusion, complemented with local therapy in the form of trans-arterial chemoembolization (TACE) or radioembolization (TARE). The broadest implementation of these embolization strategies currently lies within the treatment of untreatable hepatocellular cancer (HCC) and metastatic colorectal cancer. This review aims to describe the state-of-the-art TACE and TARE technologies investigated in the clinical setting for HCC and addresses current trials and new developments. In addition, chemical properties and advancements in microsphere carrier systems are evaluated, and possible improvements in embolization therapy based on the modification of and functionalization with therapeutical loads are explored.

13.
Mol Imaging Biol ; 25(1): 180-189, 2023 02.
Article in English | MEDLINE | ID: mdl-35711014

ABSTRACT

PURPOSE: Surgical fluorescence guidance has gained popularity in various settings, e.g., minimally invasive robot-assisted laparoscopic surgery. In pursuit of novel receptor-targeted tracers, the field of fluorescence-guided surgery is currently moving toward increasingly lower signal intensities. This highlights the importance of understanding the impact of low fluorescence intensities on clinical decision making. This study uses kinematics to investigate the impact of signal-to-background ratios (SBR) on surgical performance. METHODS: Using a custom grid exercise containing hidden fluorescent targets, a da Vinci Xi robot with Firefly fluorescence endoscope and ProGrasp and Maryland forceps instruments, we studied how the participants' (N = 16) actions were influenced by the fluorescent SBR. To monitor the surgeon's actions, the surgical instrument tip was tracked using a custom video-based tracking framework. The digitized instrument tracks were then subjected to multi-parametric kinematic analysis, allowing for the isolation of various metrics (e.g., velocity, jerkiness, tortuosity). These were incorporated in scores for dexterity (Dx), decision making (DM), overall performance (PS) and proficiency. All were related to the SBR values. RESULTS: Multi-parametric analysis showed that task completion time, time spent in fluorescence-imaging mode and total pathlength are metrics that are directly related to the SBR. Below SBR 1.5, these values substantially increased, and handling errors became more frequent. The difference in Dx and DM between the targets that gave SBR < 1.50 and SBR > 1.50, indicates that the latter group generally yields a 2.5-fold higher Dx value and a threefold higher DM value. As these values provide the basis for the PS score, proficiency could only be achieved at SBR > 1.55. CONCLUSION: By tracking the surgical instruments we were able to, for the first time, quantitatively and objectively assess how the instrument positioning is impacted by fluorescent SBR. Our findings suggest that in ideal situations a minimum SBR of 1.5 is required to discriminate fluorescent lesions, a substantially lower value than the SBR 2 often reported in literature.


Subject(s)
Coloring Agents , Surgery, Computer-Assisted , Humans
14.
Eur J Surg Oncol ; 49(10): 107006, 2023 10.
Article in English | MEDLINE | ID: mdl-37572588

ABSTRACT

INTRODUCTION: In early-stage vulvar squamous cell carcinoma (VSCC) a sentinel lymph node (SLN) procedure is regarded successful if at least one SLN is removed with minimal residual radioactivity. An inguinofemoral lymphadenectomy is considered if not all SLNs visualized on lymphoscintigraphy can be found, with subsequent increased morbidity. We correlated lymphoscintigraphy findings with surgical outcome and groin recurrence with focus on number of SLNs found. METHODS: This study concerns a retrospective cohort of 171 women treated for early-stage VSCC who underwent a SLN procedure between 2000 and 2020. The risk of groin recurrence was compared after either a successful or complete SLN procedure, i.e. removal of all SLNs that were visualized on lymphoscintigraphy. RESULTS: In 13 (7.6%) groins of 171 patients SLN visualization on lymphoscintigraphy failed. In 230 of the 246 (93.5%) groins in which a SLN was visualized, at least one SLN was found during surgery. In 224 of the 246 (91.1%) groins the SLN procedure was regarded either successful (n = 14) or complete (n = 210). An isolated groin recurrence was documented in 5 out of 192 (2.6%, 95%-CI; 0.34 to 4.9) SLN-negative groins after a median follow-up of 47.0 months. All recurrences were noted in the complete SLN group (5/180 groins). The difference with the successful SLN group (0/12 groins) was not significant. CONCLUSION: Risk of groin recurrence was 2.6% after SLN negative biopsy in early-stage VSCC. The risk appeared not increased if at least one SLN was found with minimal residual radioactivity, in case more SLNs were visualized on lymphoscintigraphy.


Subject(s)
Carcinoma, Squamous Cell , Lymphadenopathy , Sentinel Lymph Node , Vulvar Neoplasms , Humans , Female , Sentinel Lymph Node/diagnostic imaging , Sentinel Lymph Node/surgery , Sentinel Lymph Node/pathology , Groin/surgery , Groin/pathology , Vulvar Neoplasms/diagnostic imaging , Vulvar Neoplasms/surgery , Vulvar Neoplasms/pathology , Retrospective Studies , Lymphoscintigraphy/methods , Sentinel Lymph Node Biopsy/methods , Lymph Node Excision/methods , Lymph Nodes/diagnostic imaging , Lymph Nodes/surgery , Lymph Nodes/pathology , Lymphadenopathy/pathology , Carcinoma, Squamous Cell/diagnostic imaging , Carcinoma, Squamous Cell/surgery , Carcinoma, Squamous Cell/pathology , Treatment Outcome
15.
Bone Joint Res ; 12(1): 72-79, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36649933

ABSTRACT

AIMS: Arthroplasty surgery of the knee and hip is performed in two to three million patients annually. Periprosthetic joint infections occur in 4% of these patients. Debridement, antibiotics, and implant retention (DAIR) surgery aimed at cleaning the infected prosthesis often fails, subsequently requiring invasive revision of the complete prosthetic reconstruction. Infection-specific imaging may help to guide DAIR. In this study, we evaluated a bacteria-specific hybrid tracer (99mTc-UBI29-41-Cy5) and its ability to visualize the bacterial load on femoral implants using clinical-grade image guidance methods. METHODS: 99mTc-UBI29-41-Cy5 specificity for Stapylococcus aureus was assessed in vitro using fluorescence confocal imaging. Topical administration was used to highlight the location of S. aureus cultured on femoral prostheses using fluorescence imaging and freehand single photon emission CT (fhSPECT) scans. Gamma counting and fhSPECT were used to quantify the bacterial load and monitor cleaning with chlorhexidine. Microbiological culturing helped to relate the imaging findings with the number of (remaining) bacteria. RESULTS: Bacteria could be effectively stained in vitro and on prostheses, irrespective of the presence of biofilm. Infected prostheses revealed bacterial presence on the transition zone between the head and neck, and in the screw hole. Qualitative 2D fluorescence images could be complemented with quantitative 3D fhSPECT scans. Despite thorough chlorhexidine treatments, 28% to 44% of the signal remained present in the locations of the infection that were identified using imaging, which included 500 to 2,000 viable bacteria. CONCLUSION: The hybrid tracer 99mTc-UBI29-41-Cy5 allowed effective bacterial staining. Qualitative real-time fluorescence guidance could be effectively combined with nuclear imaging that enables quantitative monitoring of the effectiveness of cleaning strategies.Cite this article: Bone Joint Res 2023;12(1):72-79.

16.
Semin Nucl Med ; 52(6): 745-758, 2022 11.
Article in English | MEDLINE | ID: mdl-35643531

ABSTRACT

Positron emission tomography (PET) is an important imaging modality for personalizing clinical management of patients with lung cancer. In this regard, PET imaging is essential for adequate clinical staging and monitoring of treatment response in patients with lung cancer. The key advantage of PET over other radiological imaging modalities is its high sensitivity for the detection of pulmonary lesions, normal-sized metastatic hilar and/or mediastinal lymph nodes, and distant metastases. Furthermore, with increasing clinical evidence, the role of PET imaging for treatment selection, adaptation, early response monitoring and follow up in patients with lung cancer is being increasingly recognized. At the heart of PET imaging lies the ability to visualize and quantify numerous biological parameters that are responsible for treatment resistance. In order to ensure accurate and reproducible image quantification, harmonization of patient preparation and imaging protocols is essential. Additionally, there are several technical factors during PET scanning that have to be taken care of to safeguard image quality and quantitative accuracy. One of these factors is the occurrence of respiratory motion artifacts, which is a well-known factor that can significantly influence image quality and quantitative accuracy of PET images. If left uncorrected, respiratory motion artifacts can introduce uncertainties in diagnosis and staging, inaccuracies in definition of target volumes for radiation treatment planning, and hinder adequate monitoring of therapy response. Although many different respiratory gating techniques have been developed to correct PET images for respiratory motion artifacts, respiratory gating has traditionally not been widely adopted in clinical practice. This is due to the fact that these methods tend to be disruptive for the clinical workflow due the lengthening of image acquisition times, higher amounts of activity being administered to the patient, and the requirement to synchronize additional hardware with the scanner. Developments in respiratory gating techniques over the last years have resulted in considerable technical improvements. These newer respiratory gating techniques can operate directly on the acquired PET data without the use of additional hardware to trace respiratory motion and can be seamlessly applied into clinical routine. Furthermore, instead of only using a fraction of the acquired PET data newer methods have the ability to use all of the acquired PET data for image reconstruction, thereby improving image quality. The clinically added value of respiratory gating lies in improving image quality by reducing the amount of respiration-induced image blurring. This considerably improves the detection and characterization of small lesions, potentially improving early diagnosis and staging of patients with lung cancer. Furthermore, the incorporation of (4D) respiratory gated PET for radiotherapy purposes has shown to improve target volume definition through more accurate tracking of tumor motion. In addition, the effect of respiratory motion artifacts on widely used volumetric and uptake parameters in PET have been described. Although respiratory gating improves quantitative accuracy of PET images, the exact impact of these corrections on clinical management of patients with lung cancer often still needs to be determined.


Subject(s)
Lung Neoplasms , Respiratory-Gated Imaging Techniques , Humans , Positron-Emission Tomography/methods , Artifacts , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/therapy , Image Processing, Computer-Assisted , Respiration , Respiratory-Gated Imaging Techniques/methods
17.
Clin Nucl Med ; 47(9): 774-780, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-35713891

ABSTRACT

RATIONALE: In muscle-invasive bladder cancer (MIBC), lymph node invasion has proven to be an independent predictor of disease recurrence and cancer-specific survival. We evaluated the feasibility of targeting the sentinel node (SN) for biopsy in MIBC patients using the hybrid tracer indocyanine green (ICG)- 99m Tc-nanocolloid for simultaneous radioguidance and fluorescence guidance. METHODS: Twenty histologically confirmed cN0M0 MIBC patients (mean age, 63.3 years; range, 30-82 years), scheduled for radical cystectomy with SN biopsy and extended pelvic lymph node dissection (ePLND), were prospectively included. Twelve patients were operated on following neoadjuvant chemotherapy. The patients received lymphoscintigraphy as well as SPECT/CT after 4 transurethral injections of ICG- 99m Tc-nanocolloid (mean, 208 MBq; range, 172-229 MBq) around the tumor/scar in the detrusor muscle of the bladder on the day before radical cystectomy. Sentinel node resection was performed under radioguidance and fluorescence guidance. RESULTS: Nineteen patients could be analyzed. On preoperative imaging, SNs could be identified in 10 patients (53%; mean, 1.6 SN/patient), which revealed drainage pathways outside the ePLND in 20% of the patients. Interesting to note is that 2 patients (10%) with preoperative nonvisualization displayed fluorescent and radioactive SNs during surgery. Location of the primary tumor near the left lateral side of the bladder seemed to be a factor for nonvisualization. Nodal harvesting with ePLND varied among patients (mean, 23.3). Histopathology confirmed tumor-positive nodes in 4 (21%) of all patients. In the 2 patients where an SN could be identified, the ePLND specimens were tumor-negative. All patients with tumor-positive nodes had advanced disease (stage III). CONCLUSION: Sentinel node biopsy in bladder cancer using the hybrid tracer ICG- 99m Tc-nanocolloid is feasible, and preoperative imaging is predictive for the ability to perform SN biopsy in 83% of the patients who displayed an SN. In patients with a successful preoperative SN mapping using lymphoscintigraphy and SPECT/CT, the intraoperative SN guidance and detection were effective, even outside the ePLND area. As such, this study underscores the critical role that preoperative imaging plays in challenging image-guided surgery applications.


Subject(s)
Sentinel Lymph Node , Urinary Bladder Neoplasms , Colloids , Humans , Indocyanine Green , Middle Aged , Nanostructures , Pilot Projects , Prospective Studies , Sentinel Lymph Node/diagnostic imaging , Sentinel Lymph Node Biopsy/methods , Technetium , Technetium Tc 99m Aggregated Albumin , Urinary Bladder Neoplasms/diagnostic imaging
18.
Int J Comput Assist Radiol Surg ; 17(10): 1775-1785, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35934773

ABSTRACT

PURPOSE: Navigational strategies create a scenario whereby percutaneous needle-based interventions of the liver can be guided using both pre-interventional 3D imaging datasets and dynamic interventional ultrasound (US). To score how such technologies impact the needle placement process, we performed kinematic analysis on different user groups. METHODS: Using a custom biopsy phantom, three consecutive exercises were performed by both novices and experts (n = 26). The exercise came in three options: (1) US-guidance, (2) US-guidance with pre-interventional image-registration (US + Reg) and (3) US-guidance with pre-interventional image-registration and needle-navigation (US + Reg + Nav). The traveled paths of the needle were digitized in 3D. Using custom software algorithms, kinematic metrics were extracted and related to dexterity, decision making indices to obtain overall performance scores (PS). RESULTS: Kinematic analysis helped quantifying the visual assessment of the needle trajectories. Compared to US-guidance, novices yielded most improvements using Reg (PSavg(US) = 0.43 vs. PSavg(US+Reg) = 0.57 vs. PSavg(US+Reg+Nav) = 0.51). Interestingly, the expert group yielded a reversed trend (PSavg(US) = 0.71 vs PSavg(US+Reg) = 0.58 vs PSavg(US+Reg+Nav) = 0.59). CONCLUSION: Digitizing the movement trajectory allowed us to objectively assess the impact of needle-navigation strategies on percutaneous procedures. In particular, our findings suggest that these advanced technologies have a positive impact on the kinematics derived performance of novices.


Subject(s)
Needles , Surgery, Computer-Assisted , Computers , Humans , Phantoms, Imaging , Surgery, Computer-Assisted/methods , Ultrasonography , Ultrasonography, Interventional/methods
19.
Cancer Imaging ; 22(1): 48, 2022 Sep 06.
Article in English | MEDLINE | ID: mdl-36068619

ABSTRACT

Molecular imaging technologies are increasingly used to diagnose, monitor, and guide treatment of i.e., cancer. In this review, the current status and future prospects of the use of molecular imaging as an instrument to help realize precision surgery is addressed with focus on the main components that form the conceptual basis of intraoperative molecular imaging. Paramount for successful interventions is the relevance and accessibility of surgical targets. In addition, selection of the correct combination of imaging agents and modalities is critical to visualize both microscopic and bulk disease sites with high affinity and specificity. In this context developments within engineering/imaging physics continue to drive the growth of image-guided surgery. Particularly important herein is enhancement of sensitivity through improved contrast and spatial resolution, features that are critical if sites of cancer involvement are not to be overlooked during surgery. By facilitating the connection between surgical planning and surgical execution, digital surgery technologies such as computer-aided visualization nicely complement these technologies. The complexity of image guidance, combined with the plurality of technologies that are becoming available, also drives the need for evaluation mechanisms that can objectively score the impact that technologies exert on the performance of healthcare professionals and outcome improvement for patients.


Subject(s)
Neoplasms , Surgery, Computer-Assisted , Humans , Molecular Imaging , Neoplasms/diagnostic imaging , Neoplasms/surgery , Surgery, Computer-Assisted/methods
20.
Diagnostics (Basel) ; 12(12)2022 Dec 14.
Article in English | MEDLINE | ID: mdl-36553163

ABSTRACT

Background: Management of patients with radioiodine (RAI)-refractory differentiated thyroid cancer (DTC) is a challenge as I-131 therapy is deemed ineffective while standard-of-care systemic therapy with tyrosine kinase inhibitor (TKI) lenvatinib is associated with frequent toxicities leading to dose reductions and withdrawal. A potential new treatment approach is to use TKIs as redifferentiation agent to restore RAI uptake to an extent that I-131 therapy is warranted. Prior studies show that short-term treatment with other TKIs restores RAI uptake in 50-60% of radioiodine-refractory DTC patients, but this concept has not been investigated for lenvatinib. Furthermore, the optimal duration of treatment with TKIs for maximal redifferentiation has not been explored. Methods and Design: A total of 12 patients with RAI-refractory DTC with an indication for lenvatinib will undergo I-124 PET/CT to quantify RAI uptake. This process is repeated after 6 and 12 weeks post-initiating lenvatinib after which the prospective dose estimate to target lesions and organs at risk will be determined. Patients will subsequently stop lenvatinib and undergo I-131 treatment if it is deemed effective and safe by predefined norms. The I-124 PET/CT measurements after 6 and 12 weeks of the first six patients are compared and the optimal timepoint will be determined for the remaining patients. In all I-131 treated patients post-therapy SPECT/CT dosimetry verification will be performed. During follow-up, clinical response will be evaluated using serum thyroglobulin levels and F-18 FDG PET/CT imaging for 6 months. It is hypothesized that at least 40% of patients will show meaningful renewed RAI uptake after short-term lenvatinib treatment. Discussion: Shorter treatment duration of lenvatinib treatment is preferred because of frequent toxicity-related dose reductions and drug withdrawals in long-term lenvatinib treatment. Short-term treatment with lenvatinib with subsequent I-131 therapy poses a potential new management approach for these patients. Since treatment duration is reduced and I-131 therapy is more tolerable for most patients, this potentially leads to less toxicity and higher quality of life. Identifying RAI-refractory DTC patients who redifferentiate after lenvatinib therapy is therefore crucial. Trial Registration: ClinicalTrials.gov, NTC04858867.

SELECTION OF CITATIONS
SEARCH DETAIL