Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 83
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 751-759, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36166095

ABSTRACT

PURPOSE: Computer-assisted surgery (CAS) total knee arthroplasty (TKA) remains a controversial area of surgical practice. The aim of this study is to report the ten-year revision rates and patient-reported outcome measures (PROMS) of a single-blinded, prospective, randomised controlled trial comparing electromagnetically (EM) navigated and conventional TKA. METHODS: 199 patients were randomised to receive either EM navigated or conventional TKA where the aim of implantation was neutral mechanical alignment in all cases. Ten-year revision rates were collated and compared between the two intervention groups. Longitudinal PROMS data was collected prospectively at various time points up to 10 years post-operatively. RESULTS: Over the ten-year period, there were 23 deaths (22.8%) in the EM navigation cohort and 30 deaths (30.6%) in the conventional cohort. At 10 years post-operatively, there was no statistically significant difference in all cause revision between the EM navigation and conventional cohort (4.0 vs 6.1%, p = 0.429). When analysing causes of revision that might be influenced by utilising EM navigation, there was no statistically significant difference in revisions (3.0% EM navigated vs 4.1% conventional group, p = 0.591). Patients that received navigated TKAs had improved Oxford Knee Society, American Knee Society Score and range of motion at 3 months following surgery compared to conventional TKA (p = 0.002, p = 0.032, and p = 0.05, respectively). However, from 1 to 10 years post-operatively, both interventions had equivalent outcomes. CONCLUSION: There is no difference in revision rates or clinical outcomes comparing EM navigated versus conventional TKA at ten-year follow-up. The expected mortality rate makes it unlikely that a difference in revision rates will reach statistical significance in the future. In the setting of an experienced knee arthroplasty surgeon, it is difficult to justify the additional costs of CAS in TKA surgery. LEVEL OF EVIDENCE: I.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Surgery, Computer-Assisted , Humans , Arthroplasty, Replacement, Knee/methods , Prospective Studies , Treatment Outcome , Knee Joint/surgery , Surgery, Computer-Assisted/methods , Osteoarthritis, Knee/surgery
2.
Dev Sci ; 25(3): e13195, 2022 05.
Article in English | MEDLINE | ID: mdl-34800316

ABSTRACT

Movement is prospective. It structures self-generated engagement with objects and social partners and is fundamental to children's learning and development. In autistic children, previous reports of differences in movement kinematics compared to neurotypical peers suggest that its prospective organisation might be disrupted. Here, we employed a smart tablet serious game paradigm to assess differences in the feedforward and feedback mechanisms of prospective action organisation, between autistic and neurotypical preschool children. We analysed 3926 goal-directed finger movements made during smart-tablet ecological gameplay, from 28 children with Childhood Autism (ICD-10; ASD) and 43 neurotypical children (TD), aged 3-6 years old. Using linear and generalised linear mixed-effect models, we found the ASD group executed movements with longer movement time (MT) and time to peak velocity (TTPV), lower peak velocity (PV), with PV less likely to occur in the first movement unit (MU) and with a greater number of movement units after peak velocity (MU-APV). Interestingly, compared to the TD group, the ASD group showed smaller increases in PV, TTPV and MT with an increase in age (ASD × age interaction), together with a smaller reduction in MU-APV and an increase in MU-APV at shorter target distances (ASD × Dist interaction). Our results are the first to highlight different developmental trends in anticipatory feedforward and compensatory feedback mechanisms of control, contributing to differences in movement kinematics observed between autistic and neurotypical children. These findings point to differences in integration of prospective perceptuomotor information, with implications for embodied cognition and learning from self-generated action in autism.


Subject(s)
Autism Spectrum Disorder , Autistic Disorder , Child , Child, Preschool , Goals , Humans , Prospective Studies , Tablets
3.
Arch Toxicol ; 96(3): 817-830, 2022 03.
Article in English | MEDLINE | ID: mdl-35034154

ABSTRACT

There exists consensus that the traditional means by which safety of chemicals is assessed-namely through reliance upon apical outcomes obtained following in vivo testing-is increasingly unfit for purpose. Whilst efforts in development of suitable alternatives continue, few have achieved levels of robustness required for regulatory acceptance. An array of "new approach methodologies" (NAM) for determining toxic effect, spanning in vitro and in silico spheres, have by now emerged. It has been suggested, intuitively, that combining data obtained from across these sources might serve to enhance overall confidence in derived judgment. This concept may be formalised in the "tiered assessment" approach, whereby evidence gathered through a sequential NAM testing strategy is exploited so to infer the properties of a compound of interest. Our intention has been to provide an illustration of how such a scheme might be developed and applied within a practical setting-adopting for this purpose the endpoint of rat acute oral lethality. Bayesian statistical inference is drawn upon to enable quantification of degree of confidence that a substance might ultimately belong to one of five LD50-associated toxicity categories. Informing this is evidence acquired both from existing in silico and in vitro resources, alongside a purposely-constructed random forest model and structural alert set. Results indicate that the combination of in silico methodologies provides moderately conservative estimations of hazard, conducive for application in safety assessment, and for which levels of certainty are defined. Accordingly, scope for potential extension of approach to further toxicological endpoints is demonstrated.


Subject(s)
Risk Assessment/methods , Toxicity Tests, Acute/methods , Toxicology/methods , Animals , Bayes Theorem , Chemical Safety/methods , Computer Simulation , Lethal Dose 50 , Rats
4.
Br J Cancer ; 125(12): 1666-1676, 2021 12.
Article in English | MEDLINE | ID: mdl-34663950

ABSTRACT

BACKGROUND: The absence of the putative DNA/RNA helicase Schlafen11 (SLFN11) is thought to cause resistance to DNA-damaging agents (DDAs) and PARP inhibitors. METHODS: We developed and validated a clinically applicable SLFN11 immunohistochemistry assay and retrospectively correlated SLFN11 tumour levels to patient outcome to the standard of care therapies and olaparib maintenance. RESULTS: High SLFN11 associated with improved prognosis to the first-line treatment with DDAs platinum-plus-etoposide in SCLC patients, but was not strongly linked to paclitaxel-platinum response in ovarian cancer patients. Multivariate analysis of patients with relapsed platinum-sensitive ovarian cancer from the randomised, placebo-controlled Phase II olaparib maintenance Study19 showed SLFN11 tumour levels associated with sensitivity to olaparib. Study19 patients with high SLFN11 had a lower progression-free survival (PFS) hazard ratio compared to patients with low SLFN11, although both groups had the benefit of olaparib over placebo. Whilst caveated by small sample size, this trend was maintained for PFS, but not overall survival, when adjusting for BRCA status across the olaparib and placebo treatment groups, a key driver of PARP inhibitor sensitivity. CONCLUSION: We provide clinical evidence supporting the role of SLFN11 as a DDA therapy selection biomarker in SCLC and highlight the need for further clinical investigation into SLFN11 as a PARP inhibitor predictive biomarker.


Subject(s)
DNA Damage/genetics , Nuclear Proteins/metabolism , Animals , Female , Humans , Male , Mice , Mice, Nude , Retrospective Studies , Treatment Outcome
5.
J Arthroplasty ; 36(10): 3451-3455, 2021 10.
Article in English | MEDLINE | ID: mdl-34226082

ABSTRACT

BACKGROUND: The objective of this study is to provide the 5-year follow-up results of a randomized study comparing conventional versus electromagnetic computer navigated total knee arthroplasty. METHODS: Analysis of 127 patients (66 navigated and 61 conventional surgeries) was performed from a prospective, single-blinded, randomized controlled trial. Patient-reported outcome measures were collected at 5 years after surgery and compared with previously published 1-year clinical outcomes. Five-year surgical revision rates were collated and compared between intervention groups. RESULTS: Overall, there have been continued improvements in the clinical scores of patients in both groups when compared with clinical data at 1 year; however, at 5 years, there is no statistical difference in any of the patient-reported outcome measures between conventional and navigated surgery. Interestingly, improved implant survivorship was observed in the navigated (0% revision rate) compared with the conventional group (4.9% all-cause revision rate). CONCLUSION: Electromagnetic computer navigated technology produces similar clinical outcomes compared with traditional surgery. Further work is required to monitor implant survivorship, and clinical outcomes with long-term follow-up, to determine the cost effectiveness of this technology.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Surgery, Computer-Assisted , Electromagnetic Phenomena , Follow-Up Studies , Humans , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Prospective Studies , Prosthesis Failure , Single-Blind Method , Treatment Outcome
6.
Sensors (Basel) ; 20(5)2020 Feb 25.
Article in English | MEDLINE | ID: mdl-32106577

ABSTRACT

Validation testing is a necessary step for inertial measurement unit (IMU) motion analysis for research and clinical use. Optical tracking systems utilize marker models which must be precise in measurement and mitigate skin artifacts. Prosthesis wearers present challenges to optical tracking marker model choice. Seven participants were recruited and underwent simultaneous motion capture from two marker sets; Plug in Gait (PiG) and the Strathclyde Cluster Model (SCM). Variability of joint kinematics within and between subjects was evaluated. Variability was higher for PiG than SCM for all parameters. The within-subjects variability as reported by the average standard deviation (SD), was below 5.6° for all rotations of the hip on the prosthesis side for all participants for both methods, with an average of 2.1° for PiG and 2.5° for SCM. Statistically significant differences in joint parameters caused by a change in the protocol were evident in the sagittal plane (p < 0.05) on the amputated side. Trans-tibial gait analysis was best achieved by use of the SCM. The SCM protocol appeared to provide kinematic measurements with a smaller variability than that of the PiG. Validation studies for prosthesis wearer populations must reconsider the marker protocol for gold standard comparisons with IMUs.


Subject(s)
Artificial Limbs , Gait Analysis/methods , Gait/physiology , Tibia/surgery , Ankle Joint/physiopathology , Biomechanical Phenomena , Female , Hip Joint/physiopathology , Humans , Knee Joint/physiopathology , Male , Middle Aged , Rotation
7.
Br J Cancer ; 119(9): 1075-1085, 2018 10.
Article in English | MEDLINE | ID: mdl-30353045

ABSTRACT

BACKGROUND: In Study 19, maintenance monotherapy with olaparib significantly prolonged progression-free survival vs placebo in patients with platinum-sensitive, recurrent high-grade serous ovarian cancer. METHODS: Study 19 was a randomised, placebo-controlled, Phase II trial enrolling 265 patients who had received at least two platinum-based chemotherapy regimens and were in complete or partial response to their most recent regimen. Patients were randomised to olaparib (capsules; 400 mg bid) or placebo. We present long-term safety and final mature overall survival (OS; 79% maturity) data, from the last data cut-off (9 May 2016). RESULTS: Thirty-two patients (24%) received maintenance olaparib for over 2 years; 15 (11%) did so for over 6 years. No new tolerability signals were identified with long-term treatment and adverse events were generally low grade. The incidence of discontinuations due to adverse events was low (6%). An apparent OS advantage was observed with olaparib vs placebo (hazard ratio 0.73, 95% confidence interval 0.55‒0.95, P = 0.02138) irrespective of BRCA1/2 mutation status, although the predefined threshold for statistical significance was not met. CONCLUSIONS: Study 19 showed a favourable final OS result irrespective of BRCA1/2 mutation status and unprecedented long-term benefit with maintenance olaparib for a subset of platinum-sensitive, recurrent ovarian cancer patients.


Subject(s)
Antineoplastic Agents/administration & dosage , Cystadenocarcinoma, Serous/drug therapy , Neoplasm Recurrence, Local/drug therapy , Ovarian Neoplasms/drug therapy , Phthalazines/administration & dosage , Piperazines/administration & dosage , Adult , Aged , Aged, 80 and over , Antineoplastic Agents/adverse effects , BRCA1 Protein/genetics , BRCA2 Protein/genetics , Capsules , Cystadenocarcinoma, Serous/genetics , Disease-Free Survival , Double-Blind Method , Female , Humans , Maintenance Chemotherapy , Middle Aged , Mutation , Neoplasm Recurrence, Local/genetics , Ovarian Neoplasms/genetics , Phthalazines/adverse effects , Piperazines/adverse effects , Platinum/administration & dosage , Platinum/therapeutic use , Treatment Outcome , Young Adult
8.
J Arthroplasty ; 33(7S): S109-S115, 2018 07.
Article in English | MEDLINE | ID: mdl-29627257

ABSTRACT

BACKGROUND: Unicompartmental knee arthroplasty (UKA) for treatment of medial compartment osteoarthritis has potential benefits over total knee arthroplasty but UKA has a higher revision rate. Robotic-assisted UKA is increasingly common and offers more accurate implant positioning and limb alignment, lower early postoperative pain but evidence of functional outcome is lacking. The aim was to assess the clinical outcomes of a single-centre, prospective, randomised controlled trial, comparing robotic-arm-assisted UKA with conventional surgery. METHODS: A total of 139 participants were recruited and underwent robotic-arm-assisted (fixed bearing) or conventional (mobile bearing) UKA. Fifty-eight patients in the robotic-arm-assisted group and 54 in the manual group at 2 years. The main outcome measures were the Oxford Knee Score, American Knee Society Score and revision rate. RESULTS: At 2 years, there were no significant differences for any of the outcome measures. Sub-group analysis (n = 35) of participants with a preoperative University of California Los Angeles Activity Scale >5 (more active) was performed. In this sub-group, the median Oxford Knee Score at 2 years was 46 (IQR 42.0-48.0) for robotic-arm-assisted and 41 (IQR 38.5-44.0) for the manual group (P = .036). The median American Knee Society Score was 193.5 (IQR 184.0-198.0) for the robotic-arm-assisted group and 174.0 (IQR 166.0-188.5) for the manual group (P = .017). Survivorship was 100% in robotic-arm-assisted group and 96.3% in the manual group. CONCLUSION: Overall, participants achieved an outcome equivalent to the most widely implanted UKA in the United Kingdom. Sub-group analysis suggests that more active patients may benefit from robotic-arm- assisted surgery. Long term follow-up is required to evaluate differences in survivorship.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Robotic Surgical Procedures , Adult , Aged , Female , Follow-Up Studies , Humans , Knee Prosthesis , Male , Middle Aged , Pain, Postoperative/prevention & control , Prospective Studies , Severity of Illness Index , Treatment Outcome , United Kingdom
9.
Lancet Oncol ; 17(11): 1579-1589, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27617661

ABSTRACT

BACKGROUND: In patients with platinum-sensitive recurrent serous ovarian cancer, maintenance monotherapy with the PARP inhibitor olaparib significantly improves progression-free survival versus placebo. We assessed the effect of maintenance olaparib on overall survival in patients with platinum-sensitive recurrent serous ovarian cancer, including those with BRCA1 and BRCA2 mutations (BRCAm). METHODS: In this randomised, placebo-controlled, double-blind, phase 2 trial involving 82 sites across 16 countries, patients with platinum-sensitive recurrent serous ovarian cancer who had received two or more courses of platinum-based chemotherapy and had responded to their latest regimen were randomly assigned (1:1) using a computer-generated sequence to receive oral maintenance olaparib (as capsules; 400 mg twice a day) or a matching placebo by an interactive voice response system. Patients were stratified by ancestry, time to progression on penultimate platinum, and response to most recent platinum. Patients and investigators were masked to treatment assignment by the use of unique identifiers generated during randomisation. The primary endpoint of the trial was progression-free survival. In this updated analysis, we present data for overall survival, a secondary endpoint, from the third data analysis after more than 5 years' follow-up (intention-to-treat population). We did the updated overall survival analysis, described in this Article at 77% data maturity, using a two-sided α of 0·95%. As the study was not powered to assess overall survival, this analysis should be regarded as descriptive and the p values are nominal. We analysed randomly assigned patients for overall survival and all patients who received at least one dose of treatment for safety. This trial is ongoing and is registered with ClinicalTrials.gov, number NCT00753545. FINDINGS: Between Aug 28, 2008, and Feb 9, 2010, 265 patients were randomly assigned to olaparib (n=136) or placebo (n=129). 136 patients had deleterious BRCAm. The data cutoff for this analysis was Sept 30, 2015. An overall survival advantage was seen with maintenance olaparib versus placebo in all patients (hazard ratio [HR] 0·73 [95% CI 0·55-0·96]; nominal p=0·025, which did not meet the required threshold for statistical significance [p<0·0095]; median overall survival was 29·8 months [95% CI 26·9-35·7] for those treated with olaparib vs 27·8 months [24·9-33·7] for those treated with placebo), and in patients with BRCAm (HR 0·62 [95% CI 0·41-0·94] nominal p=0·025; 34·9 months [95% CI 29·2-54·6] vs 30·2 months [23·1-40·7]). The overall survival data in patients with BRCA wild-type were HR 0·83 (95% CI 0·55-1·24, nominal p=0·37; 24·5 months [19·8-35·0] for those treated with olaparib vs 26·6 months [23·1-32·5] for those treated with placebo). 11 (15%) of 74 patients with BRCAm received maintenance olaparib for 5 years or more. Overall, common grade 3 or worse adverse events in the olaparib and placebo groups were fatigue (11 [8%] of 136 patients vs four [3%] of 128) and anaemia (eight [6%] vs one [1%]). 30 (22%) of 136 patients in the olaparib group and 11 (9%) of 128 patients in the placebo group reported serious adverse events. In patients treated for 2 years or more, adverse events in the olaparib and placebo groups included low-grade nausea (24 [75%] of 32 patients vs two [40%] of five), fatigue (18 [56%] of 32 vs two [40%] of five), vomiting (12 [38%] of 32 vs zero), and anaemia (eight [25%] of 32 vs one [20%] of five); generally, events were initially reported during the first 2 years of treatment. INTERPRETATION: Despite not reaching statistical significance, patients with BRCA-mutated platinum-sensitive recurrent serous ovarian cancer receiving olaparib maintenance monotherapy after platinum-based chemotherapy appeared to have longer overall survival, supporting the reported progression-free survival benefit. Clinically useful long-term exposure to olaparib was seen with no new safety signals. Taken together, these data support both the long-term clinical benefit and tolerability of maintenance olaparib in patients with BRCA-mutated platinum-sensitive recurrent serous ovarian cancer. FUNDING: AstraZeneca.


Subject(s)
Antineoplastic Agents/therapeutic use , Cystadenocarcinoma, Serous/drug therapy , Neoplasm Recurrence, Local/drug therapy , Ovarian Neoplasms/drug therapy , Phthalazines/therapeutic use , Piperazines/therapeutic use , Poly(ADP-ribose) Polymerase Inhibitors/therapeutic use , Adult , Aged , Aged, 80 and over , BRCA1 Protein/genetics , BRCA2 Protein/genetics , Cystadenocarcinoma, Serous/mortality , Double-Blind Method , Female , Humans , Middle Aged , Mutation , Ovarian Neoplasms/mortality , Phthalazines/adverse effects , Piperazines/adverse effects
10.
Hum Brain Mapp ; 37(2): 689-703, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26621010

ABSTRACT

OBJECTIVES: Recovery of independent ambulation after stroke is a major goal. However, which rehabilitation regimen best benefits each individual is unknown and decisions are currently made on a subjective basis. Predictors of response to specific therapies would guide the type of therapy most appropriate for each patient. Although lesion topography is a strong predictor of upper limb response, walking involves more distributed functions. Earlier studies that assessed the cortico-spinal tract (CST) were negative, suggesting other structures may be important. EXPERIMENTAL DESIGN: The relationship between lesion topography and response of walking speed to standard rehabilitation was assessed in 50 adult-onset patients using both volumetric measurement of CST lesion load and voxel-based lesion-symptom mapping (VLSM) to assess non-CST structures. Two functional mobility scales, the functional ambulation category (FAC) and the modified rivermead mobility index (MRMI) were also administered. Performance measures were obtained both at entry into the study (3-42 days post-stroke) and at the end of a 6-week course of therapy. Baseline score, age, time since stroke onset and white matter hyperintensities score were included as nuisance covariates in regression models. PRINCIPAL OBSERVATIONS: CST damage independently predicted response to therapy for FAC and MRMI, but not for walk speed. However, using VLSM the latter was predicted by damage to the putamen, insula, external capsule and neighbouring white matter. CONCLUSIONS: Walk speed response to rehabilitation was affected by damage involving the putamen and neighbouring structures but not the CST, while the latter had modest but significant impact on everyday functions of general mobility and gait. Hum Brain Mapp 37:689-703, 2016. © 2015 Wiley Periodicals, Inc.


Subject(s)
Brain/pathology , Stroke Rehabilitation , Stroke/pathology , Walking , Adult , Aged , Aged, 80 and over , Disability Evaluation , Exercise Test , Female , Foot Orthoses , Humans , Image Interpretation, Computer-Assisted , Magnetic Resonance Imaging , Male , Middle Aged , Prognosis , Prospective Studies , Recovery of Function , Regression Analysis , Stroke/diagnosis , Stroke/physiopathology , Treatment Outcome , White Matter/pathology
11.
J Arthroplasty ; 31(5): 1102-8, 2016 05.
Article in English | MEDLINE | ID: mdl-26718777

ABSTRACT

BACKGROUND: Heat from bone resecting tools used in knee surgery can induce thermal osteonecrosis, potentially causing aseptic implant loosening. This study compared oscillating saws to burrs in terms of temperature generation and histologic damage. Use of irrigation to reduce bone temperature was also investigated. METHODS: Temperatures were recorded during sawing and burring with or without irrigation (uncooled or cooled). Histologic analyses were then carried out. Differences between groups were tested statistically (α = 0.05). RESULTS: On average, burring produced higher temperatures than sawing (P < .001). When uncooled irrigation was used, bone temperatures were significantly lower in sawed bone than in burred bone (P < .001). Irrigation lowered temperatures and thermal damage depths and increased osteocyte viability (P < .001). CONCLUSION: These results suggest that irrigating bone during resection could prevent osteonecrosis onset.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Bone and Bones/injuries , Bone and Bones/surgery , Hot Temperature/adverse effects , Osteonecrosis/prevention & control , Therapeutic Irrigation , Animals , Arthroplasty, Replacement, Knee/methods , Body Temperature , Cattle , Cell Survival , Osteocytes/physiology , Osteonecrosis/etiology , Osteonecrosis/physiopathology
12.
Clin Orthop Relat Res ; 473(1): 206-12, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25002214

ABSTRACT

BACKGROUND: Surgical robotics has been shown to improve the accuracy of bone preparation and soft tissue balance in unicondylar knee arthroplasty (UKA). However, although extensive data have emerged with regard to a CT scan-based haptically constrained robotic arm, little is known about the accuracy of a newer alternative, an imageless robotic system. QUESTIONS/PURPOSES: We assessed the accuracy of a novel imageless semiautonomous freehand robotic sculpting system in performing bone resection and preparation in UKA using cadaveric specimens. METHODS: In this controlled study, we compared the planned and final implant placement in 25 cadaveric specimens undergoing UKA using the new tool. A quantitative analysis was performed to determine the translational, angular, and rotational differences between the planned and achieved positions of the implants. RESULTS: The femoral implant rotational mean error was 1.04° to 1.88° and mean translational error was 0.72 to 1.29 mm across the three planes. The tibial implant rotational mean error was 1.48° to 1.98° and the mean translational error was 0.79 to 1.27 mm across the three planes. CONCLUSIONS: The image-free robotic sculpting tool achieved accurate implementation of the surgical plan with small errors in implant placement. The next step will be to determine whether accurate implant placement translates into a clinical and functional benefit for the patient.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Femur/surgery , Knee Joint/surgery , Robotics/instrumentation , Surgery, Computer-Assisted/instrumentation , Tibia/surgery , Anatomic Landmarks , Arthroplasty, Replacement, Knee/methods , Biomechanical Phenomena , Cadaver , Equipment Design , Femur/anatomy & histology , Femur/physiology , Humans , Knee Joint/anatomy & histology , Knee Joint/physiology , Knee Prosthesis , Materials Testing , Surgery, Computer-Assisted/methods , Tibia/anatomy & histology , Tibia/physiology
13.
J Arthroplasty ; 30(2): 199-205, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25263246

ABSTRACT

We report on the results of a randomized study (n=200) to compare total knee arthroplasty performed using conventional instrumentation or electromagnetic computer assisted surgical technique. 92% of navigated and 85% of conventional knees were implanted within ±3° from neutral mechanical alignment; there was no statistically significant difference between these proportions. There was also no difference in femoral or tibial rotation assessed by CT scan. At 1year follow up there was no statistical difference between the two groups in American Knee Society Score, Oxford Knee Scores, patient satisfaction, quality of life, hospital length of stay, complication rates or other adverse events. Tourniquet time in the navigated group was longer. Proving value for navigation in total knee arthroplasty surgery remains a challenge.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Knee Joint/surgery , Surgery, Computer-Assisted , Adult , Aged , Aged, 80 and over , Electromagnetic Phenomena , Female , Femur/surgery , Humans , Knee Prosthesis , Male , Middle Aged , Quality of Life , Rotation , Single-Blind Method , Tibia/surgery , Tomography, X-Ray Computed
14.
J Arthroplasty ; 29(2): 377-82, 2014 Feb.
Article in English | MEDLINE | ID: mdl-23958234

ABSTRACT

Total hip arthroplasty (THA) is regarded as one of the most successful surgical procedures of modern times yet continues to be associated with a small but significant complication rate. Many early failures may be associated with poor component positioning with, in particular, acetabular component orientation dependent on the subjective judgement of the surgeon. In this paper, we compare the manufacturers' instructions on acetabular cup orientation with the literature-based recommended safety zones and surgical technique, by transforming them onto a single, clinically-relevant framework in which the different reference systems, safety guidelines and current instrumentation surgical techniques can be evaluated. The observed limited consensus between results reflects ongoing uncertainty regarding the optimum acetabular component positioning. As malpositioning of the acetabular cup increases the risk of revision surgery, any ambiguity over the correct position can have a causal effect. Our analysis highlights the need for a surgical reference system which can be used to describe the position of the acetabular cup intra-operatively.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Arthroplasty, Replacement, Hip/instrumentation , Humans , Registries
15.
ScientificWorldJournal ; 2013: 486146, 2013.
Article in English | MEDLINE | ID: mdl-24348164

ABSTRACT

Residual limb shape capturing (Casting) consistency has a great influence on the quality of socket fit. Magnetic Resonance Imaging was used to establish a reliable reference grid for intercast and intracast shape and volume consistency of two common casting methods, Hands-off and Hands-on. Residual limbs were cast for twelve people with a unilateral below knee amputation and scanned twice for each casting concept. Subsequently, all four volume images of each amputee were semiautomatically segmented and registered to a common coordinate system using the tibia and then the shape and volume differences were calculated. The results show that both casting methods have intra cast volume consistency and there is no significant volume difference between the two methods. Inter- and intracast mean volume differences were not clinically significant based on the volume of one sock criteria. Neither the Hands-off nor the Hands-on method resulted in a consistent residual limb shape as the coefficient of variation of shape differences was high. The resultant shape of the residual limb in the Hands-off casting was variable but the differences were not clinically significant. For the Hands-on casting, shape differences were equal to the maximum acceptable limit for a poor socket fit.


Subject(s)
Amputees , Artificial Limbs , Leg , Magnetic Resonance Imaging , Prosthesis Fitting , Artificial Limbs/standards , Humans , Prosthesis Fitting/standards
16.
JMIR Rehabil Assist Technol ; 10: e46619, 2023 Jul 21.
Article in English | MEDLINE | ID: mdl-37477954

ABSTRACT

BACKGROUND: Rehabilitation improves poststroke recovery with greater effect for many when applied intensively within enriched environments. The failure of health care providers to achieve minimum recommendations for rehabilitation motivated the development of a technology-enriched rehabilitation gym (TERG) that enables individuals under supervision to perform high-intensity self-managed exercises safely in an enriched environment. OBJECTIVE: This study aimed to assess the feasibility of the TERG approach and gather preliminary evidence of its effect for future research. METHODS: This feasibility study recruited people well enough to exercise but living with motor impairment following a stroke at least 12 months previously. Following assessment, an 8-week exercise program using a TERG (eg, virtual reality treadmills, power-assisted equipment, balance trainers, and upper limb training systems) was structured in partnership with participants. The feasibility was assessed through recruitment, retention, and adherence rates along with participant interviews. Effect sizes were calculated from the mean change in standard outcome measures. RESULTS: In total, 70 individuals registered interest, the first 50 were invited for assessment, 39 attended, and 31 were eligible and consented. Following a pilot study (n=5), 26 individuals (mean age 60.4, SD 13.3 years; mean 39.0, SD 29.2 months post stroke; n=17 males; n=10 with aphasia) were recruited to a feasibility study, which 25 individuals completed. Participants attended an average of 18.7 (SD 6.2) sessions with an 82% attendance rate. Reasons for nonattendance related to personal life, illness, weather, care, and transport. In total, 19 adverse events were reported: muscle or joint pain, fatigue, dizziness, and viral illness, all resolved within a week. Participants found the TERG program to be a positive experience with the equipment highly usable albeit with some need for individual tailoring to accommodate body shape and impairment. The inclusion of performance feedback and gamification was well received. Mean improvements in outcome measures were recorded across all domains with low to medium effect sizes. CONCLUSIONS: This study assessed the feasibility of a holistic technology-based solution to the gap between stroke rehabilitation recommendations and provision. The results clearly demonstrate a rehabilitation program delivered through a TERG is feasible in terms of recruitment, retention, adherence, and user acceptability and may lead to considerable improvement in function, even in a chronic stroke population. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-doi.org/10.3389/fresc.2021.820929.

17.
Age Ageing ; 41(2): 224-30, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22126987

ABSTRACT

OBJECTIVE: to investigate the association between muscle strength, biomechanical functional moments during everyday tasks and health-related quality of life (HRQoL) in older adults. METHODS: eighty-four healthy adults aged 60-88 years were tested. A torque dynamometer was utilised to measure muscle moments at the knee and hip joints. Functional assessment involved three-dimensional biomechanical analysis of gait, chair rise and sit-down, stair ascent and descent using an 8-camera VICON® system with Kistler force plates. HRQoL was assessed using the Short Form-36 (SF-36) questionnaire. RESULTS: Spearman's correlation coefficient showed significant correlation (P < 0.001) between isometric strength and functional moments (r = 0.24-0.67). Muscle strength was significantly correlated with SF-36 scores, including physical functioning, bodily pain, vitality, social functioning and role emotional scores. Knee flexion moment was correlated with role physical, vitality, social functioning, role emotional, mental health and mental component scores (r = 0.24-0.40). CONCLUSION: loss of muscle strength is associated with poorer functional ability and both are associated with reduced HRQoL. The reduction in HRQoL is considerable in the physical functioning domain. Cause and effect was not established but studies need to be undertaken to evaluate the benefits of strength training, functional activity training or increased participation in life.


Subject(s)
Activities of Daily Living , Aging , Health Status , Muscle Strength , Muscle, Skeletal/physiopathology , Muscular Diseases/physiopathology , Quality of Life , Age Factors , Aged , Aged, 80 and over , Aging/psychology , Biomechanical Phenomena , Female , Hip Joint/physiopathology , Humans , Isometric Contraction , Knee Joint/physiopathology , Male , Middle Aged , Muscle Strength Dynamometer , Muscular Diseases/psychology , Scotland , Surveys and Questionnaires , Torque , Video Recording
18.
Rheumatol Int ; 32(5): 1277-84, 2012 May.
Article in English | MEDLINE | ID: mdl-21267571

ABSTRACT

Hypermobility syndrome (HMS) is a major source of morbidity in children. Impaired quality of life (QoL) has been observed recently in adults with HMS; however, this issue is yet to be investigated in children with this condition. This study compared pain intensity and QoL in children with HMS with healthy controls. It also examined the relationship between pain intensity and QoL in children with HMS. Following ethical approval, 29 children diagnosed with HMS and 37 healthy children aged 8-15 years participated. Informed written consent was obtained from participants and their parents/guardians. Average knee pain over the past week was examined using the Coloured Analogue Scale. QoL was measured via the Pediatric Quality of Life Inventory. Mann-Whitney U tests were performed to compare pain and QoL scores between the two groups. Spearman Rho correlation analysis was performed to examine the relationship between pain and QoL. Overall QoL scores in each domain were significantly lower in children with HMS (all p < 0.001) compared with the controls. Pain intensity was significantly higher in children with HMS compared with their healthy counterparts (p < 0.001). A strong negative correlation was observed between pain intensity and overall QoL and all the domains (r range = -0.614 to -0.717; all p < 0.001). In conclusion, the findings of the present study imply that pain and QoL assessment might form important components of clinical examination for children diagnosed with HMS. These children may benefit from appropriate treatment programmes to alleviate pain intensity and improve QoL.


Subject(s)
Arthralgia/etiology , Joint Instability/complications , Knee Joint/physiopathology , Perception , Quality of Life , Adolescent , Age Factors , Arthralgia/diagnosis , Arthralgia/physiopathology , Arthralgia/psychology , Case-Control Studies , Child , Cost of Illness , Cross-Sectional Studies , Humans , Joint Instability/diagnosis , Joint Instability/physiopathology , Joint Instability/psychology , Pain Measurement , Predictive Value of Tests , Scotland , Self Report , Severity of Illness Index , Syndrome
19.
ScientificWorldJournal ; 2012: 156186, 2012.
Article in English | MEDLINE | ID: mdl-22619599

ABSTRACT

Lower limb prosthetic socket shape and volume consistency can be quantified using MRI technology. Additionally, MRI images of the residual limb could be used as an input data for CAD-CAM technology and finite element studies. However, the accuracy of MRI when socket casting materials are used has to be defined. A number of six, 46 mm thick, cross-sections of an animal leg were used. Three specimens were wrapped with Plaster of Paris (POP) and the other three with commercially available silicone interface liner. Data was obtained by utilising MRI technology and then the segmented images compared to corresponding calliper measurement, photographic imaging, and water suspension techniques. The MRI measurement results were strongly correlated with actual diameter, surface area, and volume measurements. The results show that the selected scanning parameters and the semiautomatic segmentation method are adequate enough, considering the limit of clinical meaningful shape and volume fluctuation, for residual limb volume and the cross-sectional surface area measurements.


Subject(s)
Amputation Stumps , Artificial Limbs , Magnetic Resonance Imaging/methods , Prosthesis Fitting , Animals
20.
Bone Joint J ; 104-B(4): 433-443, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35360949

ABSTRACT

AIMS: The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery. METHODS: A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined proprioception outcomes during a joint position sense test and one-leg standing. Surgery allocation, surgeon, and secondary outcomes were analyzed for prediction of the primary outcome from a binary regression model. RESULTS: Both interventions were shown to be effective treatment options, with no significant differences shown between interventions for the primary outcome of this study (18/35 (51.4%) biphasic TKA patients vs 20/31 (64.5%) biphasic bi-UKA patients; p = 0.558). All outcomes were compared to an age-matched, healthy cohort that outperformed both groups, indicating residual deficits exists following surgery. Logistic regression analysis of primary outcome with secondary outcomes indicated that the most significant predictor of postoperative biphasic knee moments was preoperative knee moment profile and trochlear degradation (Outerbridge) (R2 = 0.381; p = 0.002, p = 0.046). A separate regression of alignment against primary outcome indicated significant bi-UKA femoral and tibial axial alignment (R2 = 0.352; p = 0.029), and TKA femoral sagittal alignment (R2 = 0.252; p = 0.016). The bi-UKA group showed a significant increased ability in the proprioceptive joint position test, but no difference was found in more dynamic testing of proprioception. CONCLUSION: Robotic arm-assisted bi-UKA demonstrated equivalence to TKA in achieving a biphasic gait pattern after surgery for osteoarthritis of the knee. Both treatments are successful at improving gait, but both leave the patients with a functional limitation that is not present in healthy age-matched controls. Cite this article: Bone Joint J 2022;103-B(4):433-443.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Robotic Surgical Procedures , Arthroplasty, Replacement, Knee/adverse effects , Humans , Knee Joint/surgery , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL