Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 341
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Int J Cancer ; 150(11): 1861-1869, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35076933

ABSTRACT

There is no generally accepted screening strategy for prostate cancer (PCa). From February 2014 to December 2019 a randomized trial (PROBASE) recruited 46 642 men at age 45 to determine the efficacy of risk-adapted prostate-specific antigen-based (PSA) screening, starting at either 45 or 50 years. PSA tests are used to classify participants into a low (<1.5 ng/mL), intermediate (1.5-2.99 ng/mL) or high (≥3 ng/mL) risk group. In cases of confirmed PSA values ≥3 ng/mL participants are recommended a prostate biopsy with multiparametric magnetic resonance imaging (mpMRI). Half of the participants (N = 23 341) were offered PSA screening immediately at age 45; the other half (N = 23 301) were offered digital rectal examination (DRE) with delayed PSA screening at age 50. Of 23 301 participants who accepted baseline PSA testing in the immediate screening arm, 89.2% fell into the low, 9.3% into intermediate, and 1.5% (N = 344) into the high risk group. Repeat PSA measurement confirmed high-risk status for 186 men (0.8%), of whom 120 (64.5%) underwent a biopsy. A total of 48 PCas was detected (overall prevalence 0.2%), of which 15 had International Society of Uropathology (ISUP) grade 1, 29 had ISUP 2 and only 4 had ISUP ≥3 cancers. In the delayed screening arm, 23 194 participants were enrolled and 6537 underwent a DRE with 57 suspicious findings, two of which showed PCa (both ISUP 1; detection rate 0.03%). In conclusion, the prevalence of screen-detected aggressive (ISUP ≥3) PCa in 45-year-old men is very low. DRE did not turn out effective for early detection of PCa.


Subject(s)
Early Detection of Cancer , Prostatic Neoplasms , Biopsy , Humans , Male , Mass Screening/methods , Middle Aged , Polymethyl Methacrylate , Prostate-Specific Antigen , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/epidemiology , Prostatic Neoplasms/prevention & control
3.
Eur Radiol ; 31(2): 1002-1010, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32856165

ABSTRACT

OBJECTIVES: To assess the clinical utility of dual-energy CT (DE-CT)-derived iodine concentration (IC) and effective Z (Zeff) in addition to conventional CT attenuation (HU) for the discrimination between primary lung cancer (LC) and pulmonary metastases (PM) from different primary malignancies. METHODS: DE-CT scans of 79 patients with LC (3 histopathologic subgroups) and 89 patients with PM (5 histopathologic subgroups) were evaluated. Quantitative IC, Zeff, and conventional HU values were extracted and normalized to the thoracic aorta. Differences between groups were assessed by pairwise Welch's t test. Correlation and linear regression analyses were used to examine the relationship of imaging parameters in LC and PM. Diagnostic accuracy was measured by the area under receiver operator characteristic curve (AUC) and validated based on resampling methods. RESULTS: Significant differences between subgroups of LC and PMs were noted for all imaging parameters, with the highest number of significant pairs for IC. In univariate analysis, only IC was a significant diagnostic feature for discriminating LC from PM (p = 0.03). All quantitative imaging parameters correlated significantly (p < 0.0001, respectively), with the highest correlation between IC and Zeff (r = 0.91), followed by IC and HU (r = 0.76) and Zeff and HU (r = 0.73). Diagnostic models combining IC or Zeff with HU (IC+HU: AUC = 0.73; Zeff+HU: AUC = 0.69; IC+Zeff+HU: AUC = 0.73) were not significantly different and outperformed individual parameters (IC: AUC = 0.57; Zeff: AUC = 0.57; HU: AUC = 0.55) in diagnostic accuracy (p < 0.05, respectively). CONCLUSION: DE-CT-derived IC or Zeff and conventional HU represent complementary imaging parameters, which, if used in combination, may improve the differentiation between LC and PM. KEY POINTS: • Individual quantitative imaging parameters derived from DE-CT (iodine concentration, effective Z) and conventional CT (HU) provide complementary diagnostic information for the differentiation of primary lung cancer and pulmonary metastases. • A combination of conventional HU and DE-CT parameters enhances the diagnostic utility of individual parameters.


Subject(s)
Lung Neoplasms , Radiography, Dual-Energy Scanned Projection , Biomarkers , Humans , Lung Neoplasms/diagnostic imaging , Sensitivity and Specificity , Tomography, X-Ray Computed
4.
Eur Radiol ; 31(6): 4175-4183, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33211140

ABSTRACT

OBJECTIVE: Assessing the advantage of x-ray dark-field contrast over x-ray transmission contrast in radiography for the detection of developing radiation-induced lung damage in mice. METHODS: Two groups of female C57BL/6 mice (irradiated and control) were imaged obtaining both contrasts monthly for 28 weeks post irradiation. Six mice received 20 Gy of irradiation to the entire right lung sparing the left lung. The control group of six mice was not irradiated. A total of 88 radiographs of both contrasts were evaluated for both groups based on average values for two regions of interest, covering (irradiated) right lung and healthy left lung. The ratio of these average values, R, was distinguished between healthy and damaged lungs for both contrasts. The time-point when deviations of R from healthy lung exceeded 3σ was determined and compared among contrasts. The Wilcoxon-Mann-Whitney test was used to test against the null hypothesis that there is no difference between both groups. A selection of 32 radiographs was assessed by radiologists. Sensitivity and specificity were determined in order to compare the diagnostic potential of both contrasts. Inter-reader and intra-reader accuracy were rated with Cohen's kappa. RESULTS: Radiation-induced morphological changes of lung tissue caused deviations from the control group that were measured on average 10 weeks earlier with x-ray dark-field contrast than with x-ray transmission contrast. Sensitivity, specificity, and accuracy doubled using dark-field radiography. CONCLUSION: X-ray dark-field radiography detects morphological changes of lung tissue associated with radiation-induced damage earlier than transmission radiography in a pre-clinical mouse model. KEY POINTS: • Significant deviations from healthy lung due to irradiation were measured after 16 weeks with x-ray dark-field radiography (p = 0.004). • Significant deviations occur on average 10 weeks earlier for x-ray dark-field radiography in comparison to x-ray transmission radiography. • Sensitivity and specificity doubled when using x-ray dark-field radiography instead of x-ray transmission radiography.


Subject(s)
Lung , Animals , Female , Lung/diagnostic imaging , Mice , Mice, Inbred C57BL , Radiography , Sensitivity and Specificity , X-Rays
5.
J Magn Reson Imaging ; 51(6): 1727-1736, 2020 06.
Article in English | MEDLINE | ID: mdl-31875343

ABSTRACT

BACKGROUND: Muscle water T2 (T2w ) has been proposed as a biomarker to monitor disease activity and therapy effectiveness in patients with neuromuscular diseases (NMD). Multi-echo spin-echo (MESE) is known to be affected by fatty infiltration. A T2 -prepared 3D turbo spin echo (TSE) is an alternative method for T2 mapping, but has been only applied in healthy muscles. PURPOSE: To examine the performance of T2 -prepared 3D TSE in combination with spectral adiabatic inversion recovery (SPAIR) in measuring T2w in fatty infiltrated muscles based on simulations and in vivo measurements in thigh muscles of patients with NMD. STUDY TYPE: Prospective. SUBJECTS: One healthy volunteer, 34 NMD patients. FIELD STRENGTH/SEQUENCE: T2 -prepared stimulated echo acquisition mode (STEAM) magnetic resonance spectroscopy (MRS), SPAIR STEAM MRS, and SPAIR T2 -prepared STEAM MRS were performed in the subcutaneous fat of a healthy volunteer's thigh. T2 mapping based on SPAIR 2D MESE and SPAIR T2 -prepared 3D TSE was performed in the NMD patients' thigh region. Multi-TE STEAM MRS was performed for measuring a reference T2w at different thigh locations. ASSESSMENT: The behavior of the fat spectrum in the SPAIR T2 -prepared 3D TSE was simulated using Bloch simulations. The in vivo T2 results of the imaging methods were compared to the in vivo T2w MRS results. STATISTICAL TESTS: Pearson correlation coefficient with slope and intercept, relative error. RESULTS: The simulated T2 for the SPAIR T2 -prepared 3D TSE sequence remained constant within a relative error of not more than 4% up to a fat fraction of 80%. In vivo T2 values of SPAIR T2 -prepared 3D TSE were in good agreement with the T2w values of STEAM MRS (R = 0.86; slope = 1.12; intercept = -1.41 ms). In vivo T2 values of SPAIR 2D MESE showed large deviations from the T2w values of STEAM MRS (R = 0.14; slope = 0.32; intercept = 38.83 ms). DATA CONCLUSION: The proposed SPAIR T2 -prepared 3D TSE shows reduced sensitivity to fatty infiltration for T2w mapping in the thigh muscles of NMD patients. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:1727-1736.


Subject(s)
Neuromuscular Diseases , Thigh , Humans , Magnetic Resonance Imaging , Neuromuscular Diseases/diagnostic imaging , Prospective Studies , Thigh/diagnostic imaging , Water
6.
Recent Results Cancer Res ; 216: 3-30, 2020.
Article in English | MEDLINE | ID: mdl-32594383

ABSTRACT

Since their discovery by Wilhelm Conrad Röntgen in 1895, X-rays have become the most widely available, typically fastest, and usually most cost-effective medical imaging modality today. From the early radiographic approaches using X-ray films as detectors, the portfolio of medical X-ray imaging devices developed into a large range of dedicated instrumentation for various applications. While X-ray imaging has come a long way, there are some physical properties of X-rays, which have not yet been fully exploited, and which may offer quite some room for further enhancements of current X-ray imaging equipment. Firstly, X-ray imaging today is mainly black and white, despite the fact that X-ray generators actually create a full spectrum of X-ray energies, and that the interactions of X-rays that occur within the human body are not the same for all energies and every material. Exploiting these spectral dependencies allows to not only obtain a black and white CT image, but also to obtain more molecularly specific information, which is relevant particularly in oncological precision radiology. The second aspect of X-rays, and so far in radiology mainly neglected and unused, is the physical fact that X-rays can also be interpreted in the wave picture, and not only as presently been done in the particle picture. If interpreted as waves, X-rays-just like visible light-experience a phase shift in matter, and this-if exploited correctly-can produce a new class of X-ray images, which then depict the wave interactions of X-rays with matter, rather than only the attenuating properties, as done until now.


Subject(s)
Radiography/methods , Radiography/trends , Humans , X-Rays
7.
MAGMA ; 33(5): 713-724, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32048099

ABSTRACT

OBJECTIVE: To measure T2 values for magnetic resonance neurography (MRN) of the healthy distal sciatic nerve and compare those to T2 changes in patients with nerve compression. MATERIALS AND METHODS: Twenty-one healthy subjects and five patients with sciatica due to disc herniation underwent MRN using a T2-prepared turbo spin echo (TSE) sequence of the distal sciatic nerve bilaterally. Six and one of those healthy subjects further underwent a commonly used multi-echo spin-echo (MESE) sequence and magnetic resonance spectroscopy (MRS), respectively. RESULTS: T2 values derived from the T2-prepared TSE sequence were 44.6 ± 3.0 ms (left) and 44.5 ± 2.6 ms (right) in healthy subjects and showed good inter-reader reliability. In patients, T2 values of 61.5 ± 6.2 ms (affected side) versus 43.3 ± 2.4 ms (unaffected side) were obtained. T2 values of MRS were in good agreement with measurements from the T2-prepared TSE, but not with those of the MESE sequence. DISCUSSION: A T2-prepared TSE sequence enables precise determination of T2 values of the distal sciatic nerve in agreement with MRS. A MESE sequence tends to overestimate nerve T2 compared to T2 from MRS due to the influence of residual fat on T2 quantification. Our approach may enable to quantitatively assess direct nerve affection related to nerve compression.


Subject(s)
Intervertebral Disc Degeneration , Intervertebral Disc Displacement , Healthy Volunteers , Humans , Magnetic Resonance Imaging , Reproducibility of Results , Sciatic Nerve
8.
Acta Radiol ; 61(11): 1505-1511, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32064891

ABSTRACT

BACKGROUND: Lymph nodes (LN) are examined in every computed tomography (CT) scan. Until now, an evaluation is only possible based on morphological criteria. With dual-energy CT (DECT) systems, iodine concentration (IC) can be measured which could conduct in an improved diagnostic evaluation of LNs. PURPOSE: To define standard values for IC of cervical, axillary, and inguinal LNs in DECT. MATERIAL AND METHODS: Imaging data of 297 patients who received a DECT scan of the neck, thorax, abdomen-pelvis, or a combination of those in a portal-venous phase were retrospectively collected from the institutional PACS. No present history of malignancy, inflammation, or trauma in the examined region was present. For each examined region, the data of 99 patients were used. The IC of the three largest LNs, the main artery, the main vein, and a local muscle of the examined area was measured, respectively. RESULTS: Normalization of the IC of LNs to the artery, vein, muscle, or a combination of those did not lead to a decreased value-range. The smallest range and confidence interval (CI) of IC was found when using absolute values of IC for each region. Hereby, mean values (95% CI) for IC of LN were found: 2.09 mg/mL (2.00-2.18 mg/mL) for neck, 1.24 mg/mL (1.16-1.33 mg/mL) for axilla, and 1.11 mg/mL (1.04-1.17 mg/mL) for groin. CONCLUSION: The present study suggests standard values for IC of LNs in dual-layer CT could be used to differentiate between healthy and pathological lymph nodes, considering the used contrast injection protocol.


Subject(s)
Contrast Media/pharmacokinetics , Iodine/pharmacokinetics , Lymph Nodes/metabolism , Radiographic Image Enhancement/methods , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Axilla , Cohort Studies , Female , Groin , Humans , Lymph Nodes/diagnostic imaging , Male , Middle Aged , Neck , Retrospective Studies
9.
NMR Biomed ; 32(8): e4111, 2019 08.
Article in English | MEDLINE | ID: mdl-31180167

ABSTRACT

Quantitative imaging techniques are emerging in the field of magnetic resonance imaging of neuromuscular diseases (NMD). T2 of water (T2w ) is considered an important imaging marker to assess acute and chronic alterations of the muscle fibers, being generally interpreted as an indicator for "disease activity" in the muscle tissue. To validate the accuracy and robustness of quantitative imaging methods, 1 H magnetic resonance spectroscopy (MRS) can be used as a gold standard. The purpose of the present work was to investigate T2w of remaining muscle tissue in regions of higher proton density fat fraction (PDFF) in 40 patients with defined NMD using multi-TE single-voxel 1 H MRS. Patients underwent MR measurements on a 3 T system to perform a multi-TE single-voxel stimulated echo acquisition method (STEAM) MRS (TE = 11/15/20/25(/35) ms) in regions of healthy, edematous and fatty thigh muscle tissue. Muscle regions for MRS were selected based on T2 -weighted water and fat images of a two-echo 2D Dixon TSE. MRS results were confined to regions with qualitatively defined remaining muscle tissue without edema and high fat content, based on visual grading of the imaging data. The results showed decreased T2w values with increasing PDFF with R2  = 0.45 (p < 10-3 ) (linear fit) and with R2  = 0.51 (exponential fit). The observed dependence of T2w on PDFF should be considered when using T2w as a marker in NMD imaging and when performing single-voxel MRS for T2w in regions enclosing edematous, nonedematous and fatty infiltrated muscle tissue.


Subject(s)
Adipose Tissue/pathology , Muscle, Skeletal/pathology , Neuromuscular Diseases/pathology , Water/chemistry , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Protons
10.
BMC Cancer ; 19(1): 309, 2019 Apr 03.
Article in English | MEDLINE | ID: mdl-30943944

ABSTRACT

BACKGROUND: To evaluate the diagnostic value of MR imaging for the differentiation of lipomas and atypical lipomatous tumors (ALT) in comparison with histology and MDM2 amplification status. METHODS: Patients with well-differentiated lipomatous tumors (n = 113), of which 66 were diagnosed as lipoma (mean age 53 years (range, 13-82); 47% women) and 47 as atypical lipomatous tumor (ALT; mean age 60 years (range, 28-88); 64% women), were included into this study using histology and MDM2 amplification status by fluorescence in situ hybridization (FISH) as standard of reference. Preoperative MR images were retrospectively assessed by two radiologists for the following imaging features: maximum tumor diameter (mm) as well as the affected compartment (intramuscular, intermuscular or subcutaneous), septa (absent, thin (< 2 mm) or thick septa (> 2 mm) with nodular components); contrast enhancing areas within the lipomatous tumor (< 1/3 of the tumor volume, > 1/3 of the tumor volume); RESULTS: Of the 47 patients with ALT, 40 (85.1%) presented thick septa (> 2 mm) and this finding significantly increased the likelihood of ALT (OR 6.24, 95% CI 3.36-11.59; P < 0.001). The likelihood of ALT was increased if the tumor exceeded a maximum diameter of 130.0 mm (OR 2.74, 95% CI 1.82-4.11, P < 0.001). The presence of contrast enhancement in lipomatous tumors significantly increased the likelihood of ALT (Odds ratio (OR) 2.95, 95% confidence interval (CI) 2.01-4.31; P < 0.001). Of the lipomas, 21.1% were located subcutaneously, 63.6% intramuscularly and 15.2% intermuscularly. On the other hand, none of the ALTs were located subcutaneously, the majority was located intermuscularly (87.3%) and a small number of ALTs was located intramuscularly (12.7%). CONCLUSIONS: Our results suggest that using specific morphological MR imaging characteristics (maximum tumor diameter, thick septa and contrast enhancement) and the information on the localization of the lipomatous tumor, a high sensitivity and substantial specificity can be achieved for the diagnosis of lipomas and ALTs.


Subject(s)
Gene Amplification , Lipoma/diagnostic imaging , Liposarcoma/diagnostic imaging , Proto-Oncogene Proteins c-mdm2/genetics , Adolescent , Adult , Aged , Aged, 80 and over , Diagnosis, Differential , Female , Humans , In Situ Hybridization, Fluorescence , Lipoma/genetics , Liposarcoma/genetics , Magnetic Resonance Imaging/methods , Male , Middle Aged , Retrospective Studies , Sensitivity and Specificity , Young Adult
11.
J Magn Reson Imaging ; 50(3): 816-823, 2019 09.
Article in English | MEDLINE | ID: mdl-30723976

ABSTRACT

BACKGROUND: The paraspinal muscles play an important role in the onset and progression of lower back pain. It would be of clinical interest to identify imaging biomarkers of the paraspinal musculature that are related to muscle function and strength. Diffusion tensor imaging (DTI) enables the microstructural examination of muscle tissue and its pathological changes. PURPOSE: To investigate associations of DTI parameters of the lumbar paraspinal muscles with isometric strength measurements in healthy volunteers. STUDY TYPE: Prospective. SUBJECTS: Twenty-one healthy subjects (12 male, 9 female; age = 30.1 ± 5.6 years; body mass index [BMI] = 27.5 ± 2.6 kg/m2 ) were recruited. FIELD STRENGTH/SEQUENCE: 3 T/single-shot echo planar imaging (ss-EPI) DTI in 24 directions; six-echo 3D spoiled gradient echo sequence for chemical shift encoding-based water-fat separation. ASSESSMENT: Paraspinal muscles at the lumbar spine were examined. Erector spinae muscles were segmented bilaterally; cross-sectional area (CSA), proton density fat fraction (PDFF), and DTI parameters were calculated. Muscle flexion and extension maximum isometric torque values [Nm] at the back were measured with an isokinetic dynamometer and the ratio of extension to flexion strength (E/F) calculated. STATISTICAL TESTS: Pearson correlation coefficients; multivariate regression models. RESULTS: Significant positive correlations were found between the ratio of extension to flexion (E/F) strength and mean diffusivity (MD) (P = 0.019), RD (P = 0.02) and the eigenvalues (λ1: P = 0.026, λ2: P = 0.033, λ3: P = 0.014). In multivariate regression models λ3 of the erector spinae muscle λ3 and gender remained statistically significant predictors of E/F (R2adj = 0.42, P = 0.003). DATA CONCLUSION: DTI allowed the identification of muscle microstructure differences related to back muscle function that were not reflected by CSA and PDFF. DTI may potentially track subtle changes of back muscle tissue composition. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:816-823.


Subject(s)
Diffusion Tensor Imaging/methods , Muscle Strength/physiology , Paraspinal Muscles/anatomy & histology , Paraspinal Muscles/physiology , Adult , Echo-Planar Imaging , Female , Humans , Male , Prospective Studies
12.
J Magn Reson Imaging ; 50(2): 424-434, 2019 08.
Article in English | MEDLINE | ID: mdl-30684282

ABSTRACT

BACKGROUND: Adipose tissue (AT) can be classified into white and brown/beige subtypes. Chemical shift encoding-based water-fat MRI-techniques allowing simultaneous mapping of proton density fat fraction (PDFF) and T2 * result in a lower PDFF and a shorter T2 * in brown compared with white AT. However, AT T2 * values vary widely in the literature and are primarily based on 6-echo data. Increasing the number of echoes in a multiecho gradient-echo acquisition is expected to increase the precision of AT T2 * mapping. PURPOSE: 1) To mitigate issues of current T2 *-measurement techniques through experimental design, and 2) to investigate gluteal and supraclavicular AT T2 * and PDFF and their relationship using a 20-echo gradient-echo acquisition. STUDY TYPE: Prospective. SUBJECTS: Twenty-one healthy subjects. FIELD STRENGTH/SEQUENCE ASSESSMENT: First, a ground truth signal evolution was simulated from a single-T2 * water-fat model. Second, a time-interleaved 20-echo gradient-echo sequence with monopolar gradients of neck and abdomen/pelvis at 3 T was performed in vivo to determine supraclavicular and gluteal PDFF and T2 *. Complex-based water-fat separation was performed for the first 6 echoes and the full 20 echoes. AT depots were segmented. STATISTICAL TESTS: Mann-Whitney test, Wilcoxon signed-rank test and simple linear regression analysis. RESULTS: Both PDFF and T2 * differed significantly between supraclavicular and gluteal AT with 6 and 20 echoes (PDFF: P < 0.0001 each, T2 *: P = 0.03 / P < 0.0001 for 6/20 echoes). 6-echo T2 * demonstrated higher standard deviations and broader ranges than 20-echo T2 *. Regression analyses revealed a strong relationship between PDFF and T2 * values per AT compartment (R2 = 0.63 supraclavicular, R2 = 0.86 gluteal, P < 0.0001 each). DATA CONCLUSION: The present findings suggest that an increase in the number of sampled echoes beyond 6 does not affect AT PDFF quantification, whereas AT T2 * is considerably affected. Thus, a 20-echo gradient-echo acquisition enables a multiparametric analysis of both AT PDFF and T2 * and may therefore improve MR-based differentiation between white and brown fat. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:424-434.


Subject(s)
Adipose Tissue/anatomy & histology , Magnetic Resonance Imaging/methods , Adult , Buttocks/anatomy & histology , Clavicle/anatomy & histology , Female , Humans , Male , Middle Aged , Prospective Studies , Reference Values , Young Adult
13.
Eur Radiol ; 29(7): 3424-3430, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31062134

ABSTRACT

OBJECTIVE: To evaluate contrast-enhanced T1-weighted magnetic resonance (MR) images in histologically proven fibrous dysplasia (FD) for the prevalence of "milk cloud appearance" and its association with ground-glass appearance (GGA) on radiography or computed tomography (CT). METHODS: For this retrospective cohort study, 37 patients with histologically proven FD imaged preoperatively with contrast-enhanced MR imaging and radiography or CT were identified at our institution. Three radiologists independently evaluated MR images for the presence of milk cloud appearance on T1-weighted contrast-enhanced images, sites of skeletal involvement, type of bone involved, uni- vs. multifocality, mono- vs. polyostotic disease, maximum diameter, proportion of bone involved, expansile remodeling, and T2 homogeneity. The presence or absence of GGA on radiography or CT was determined in consensus. Inter-reader agreement was evaluated for milk cloud appearance using Cohen's kappa, and associations between milk cloud appearance and other imaging parameters were tested using Spearman's rho. RESULTS: Among the 37 histologically proven FD lesions, GGA was identified in 70% of the lesions, while milk cloud appearance was found in 82% of the lesions. Inter-reader agreement for milk cloud appearance on MR imaging was good to excellent (κ 0.65, 0.82, and 0.8). A significant correlation was found between milk cloud appearance and GGA (ρ = 0.31, p < 0.001). CONCLUSION: Milk cloud appearance is a characteristic sign of FD on contrast-enhanced T1-weighted MR images. Recognition of this feature may be helpful when radiographs are equivocal or unremarkable or when MR imaging is performed as the primary imaging modality in cases of FD. KEY POINTS: • Fibrous dysplasia displays a characteristic feature on contrast-enhanced T1-weighted MR imaging: milk cloud appearance. • Milk cloud appearance correlates well with the radiographic or CT finding of ground-glass appearance. • Recognition of milk cloud appearance on contrast-enhanced MR imaging may be helpful when radiographs are equivocal or unremarkable or when MR imaging is performed as the primary imaging modality in cases of fibrous dysplasia.


Subject(s)
Bone and Bones/pathology , Contrast Media/pharmacology , Fibrous Dysplasia of Bone/diagnosis , Magnetic Resonance Imaging/methods , Adolescent , Adult , Child , Female , Humans , Male , Middle Aged , Retrospective Studies , Young Adult
14.
Eur Radiol ; 29(7): 3606-3616, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30903337

ABSTRACT

PURPOSE: To systematically evaluate the effects of virtual tube current reduction and sparse sampling on image quality and vertebral fracture diagnostics in multi-detector computed tomography (MDCT). MATERIALS AND METHODS: In routine MDCT scans of 35 patients (80.0% females, 70.6 ± 14.2 years, 65.7% showing vertebral fractures), reduced radiation doses were retrospectively simulated by virtually lowering tube currents and applying sparse sampling, considering 50%, 25%, and 10% of the original tube current and projections, respectively. Two readers evaluated items of image quality and presence of vertebral fractures. Readout between the evaluations in the original images and those with virtually lowered tube currents or sparse sampling were compared. RESULTS: A significant difference was revealed between the evaluations of image quality between MDCT with virtually lowered tube current and sparse-sampled MDCT (p < 0.001). Sparse-sampled data with only 25% of original projections still showed good to very good overall image quality and contrast of vertebrae as well as minimal artifacts. There were no missed fractures in sparse-sampled MDCT with 50% reduction of projections, and clinically acceptable determination of fracture age was possible in MDCT with 75% reduction of projections, in contrast to MDCT with 50% or 75% virtual tube current reduction, respectively. CONCLUSION: Sparse-sampled MDCT provides adequate image quality and diagnostic accuracy for vertebral fracture detection with 50% of original projections in contrast to corresponding MDCT with lowered tube current. Thus, sparse sampling is a promising technique for dose reductions in MDCT that could be introduced in future generations of scanners. KEY POINTS: • MDCT with a reduction of projection numbers of 50% still showed high diagnostic accuracy without any missed vertebral fractures. • Clinically acceptable determination of vertebral fracture age was possible in MDCT with a reduction of projection numbers of 75%. • With sparse sampling, higher reductions in radiation exposure can be achieved without compromised image or diagnostic quality in routine MDCT of the spine as compared to MDCT with reduced tube currents.


Subject(s)
Artifacts , Cervical Vertebrae/injuries , Multidetector Computed Tomography/methods , Spinal Fractures/diagnosis , Thoracic Vertebrae/injuries , Adult , Aged , Aged, 80 and over , Cervical Vertebrae/diagnostic imaging , Female , Humans , Male , Middle Aged , Retrospective Studies , Thoracic Vertebrae/diagnostic imaging
15.
Eur Radiol ; 29(11): 5950-5960, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31073861

ABSTRACT

OBJECTIVES: Evaluation of sparse sampling computed tomography (SpSCT) regarding subjective and objective image criteria for the detection of pulmonary embolism (PE) at different simulated dose levels. METHODS: Computed tomography pulmonary angiography (CTPA) scans of 20 clinical patients were used to obtain simulated low-dose scans with 100%-50%-25%-12.5%-6.3%-3.1% of the clinical dose, resulting in a total of six dose levels (DL). From these full sampling (FS) data, every second (2-SpSCT) or fourth (4-SpSCT) projection was used to obtain simulated sparse sampling scans. Each image set was evaluated by four blinded radiologists regarding subjective image criteria (artifacts, image quality) and diagnostic performance (confidence, sensitivity, specificity, accuracy, and area under the curve). Additionally, the contrast-to-noise ratio (CNR) was evaluated for objective image quality. RESULTS: Sensitivity was 100% with 2-SpSCT and 4-SpSCT at the 25% DL and the 12.5% DL for all localizations of PE (one subgroup 98.5%). With FS, the sensitivity decreased to 90% at the 12.5% DL. 2-SpSCT and 4-SpSCT showed higher values for sensitivity, specificity, accuracy, and the area under the curve at all DL compared with FS. Subjective image quality was significantly higher for 4-SpSCT compared with FS at each dose level (p < 0.01, paired t test). Only with 4-SpSCT, all examinations were rated as showing diagnostic image quality at the 12.5% DL. CONCLUSIONS: Via SpSCT, a dose reduction down to a 12.5% dose level (corresponding to a mean effective dose of 0.38 mSv in the current study) for CTPA is possible while maintaining high image quality and full diagnostic confidence. KEY POINTS: • With sparse sampling CT, radiation dose could be significantly reduced in clinical routine. • Sparse sampling CT is a novel hardware solution with which less projection images are acquired. • In the current study, a dose reduction of 87.5% (corresponding to a mean effective dose of 0.38 mSv) for CTPA could be achieved while maintaining excellent diagnostic performance.


Subject(s)
Computed Tomography Angiography/methods , Pulmonary Embolism/diagnostic imaging , Analysis of Variance , Artifacts , Feasibility Studies , Humans , Lung/diagnostic imaging , Patient Safety , Radiation Dosage , Sensitivity and Specificity
16.
Eur Radiol ; 29(1): 13-21, 2019 Jan.
Article in English | MEDLINE | ID: mdl-29948069

ABSTRACT

OBJECTIVES: To evaluate the diagnostic value of MR-derived CT-like images and simulated radiographs compared with conventional radiographs in patients with benign and malignant bone tumors. METHODS: In 32 patients with a benign or malignant bone lesion (mean age 33.9 ± 18.5 years, 17 females), 3-T MR imaging was performed including a 3D T1-weighted gradient echo sequence as the basis for the CT-like images. From these, intensity-inverted MR image volumes were converted into 2D images via a forward projection to obtain simulated radiographs. Two radiologists assessed these images as well as conventional radiographs for the type of periosteal reaction, matrix mineralization and destruction pattern. Agreement between the modalities was calculated using Cohen's κ. RESULTS: The agreement between conventional radiographs and MR-derived CT-like images in combination with simulated radiographs was substantial (periosteal reaction, κ = 0.67; destruction pattern, κ = 0.75), and the sensitivity of both modalities for the final diagnosis of the lesion (aggressive vs. nonaggressive) was high (MR-derived CT-like images, 86.2% vs. conventional radiographs, 90.0%). Additional information on soft tissue extension (MR-derived CT-like images, 21.9% vs. conventional radiographs, 12.5%; p = 0.009) and lobulation (9.4% vs. 0%; p < 0.001) was significantly more often found on MR-derived CT-like images compared with conventional radiographs. CONCLUSIONS: The assessment of the destruction patterns, periosteal reaction and distinction between aggressive and nonaggressive tumors was feasible using MR-derived CT-like images and simulated radiographs and is comparable to that of conventional radiographs. Moreover, MR-derived CT-like images provided additional information on soft tissue extension and tumor architecture. KEY POINTS: • CT-like images and simulated radiographs can be generated from 3D MRI. • Evaluation of bone tumors is feasible with MR-derived images. • CT-like images and simulated radiographs provide additional information on bone tumors.


Subject(s)
Bone Diseases/diagnosis , Bone Neoplasms/diagnosis , Bone and Bones/diagnostic imaging , Computer Simulation , Magnetic Resonance Imaging/methods , Tomography, X-Ray Computed/methods , Adult , Diagnosis, Differential , Female , Humans , Male , ROC Curve
17.
Eur Radiol ; 29(11): 6355-6363, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31115622

ABSTRACT

OBJECTIVE: To investigate the in vivo applicability of non-contrast-enhanced hydroxyapatite (HA)-specific bone mineral density (BMD) measurements based on dual-layer CT (DLCT). METHODS: A spine phantom containing three artificial vertebral bodies with known HA densities was measured to obtain spectral data using DLCT and quantitative CT (QCT), simulating different patient positions and grades of obesity. BMD was calculated from virtual monoenergetic images at 50 and 200 keV. HA-specific BMD values of 174 vertebrae in 33 patients (66 ± 18 years; 33% women) were determined in non-contrast routine DLCT and compared with corresponding QCT-based BMD values. RESULTS: Examining the phantom, HA-specific BMD measurements were on a par with QCT measurements. In vivo measurements revealed strong correlations between DLCT and QCT (r = 0.987 [95% confidence interval, 0.963-1.000]; p < 0.001) and substantial agreement in a Bland-Altman plot. CONCLUSION: DLCT-based HA-specific BMD measurements were comparable with QCT measurements in in vivo analyses. This suggests that opportunistic DLCT-based BMD measurements are an alternative to QCT, without requiring phantoms and specific protocols. KEY POINTS: • DLCT-based hydroxyapatite-specific BMD measurements show a substantial agreement with QCT-based BMD measurements in vivo. • DLCT-based hydroxyapatite-specific measurements are on a par with QCT in spine phantom measurements. • Opportunistic DLCT-based BMD measurements may be a feasible alternative for QCT, without requiring dedicated examination protocols or a phantom.


Subject(s)
Absorptiometry, Photon/methods , Bone Density/physiology , Osteoporosis/diagnostic imaging , Spine/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Algorithms , Female , Humans , Male , Mass Screening/methods , Middle Aged , Osteoporosis/physiopathology , Phantoms, Imaging
18.
Eur Radiol ; 29(9): 4624-4634, 2019 Sep.
Article in English | MEDLINE | ID: mdl-30758656

ABSTRACT

OBJECTIVES: To develop and evaluate a method for areal bone mineral density (aBMD) measurement based on dual-layer spectral CT scout scans. METHODS: A post-processing algorithm using a pair of 2D virtual mono-energetic scout images (VMSIs) was established in order to semi-automatically compute the aBMD at the spine similarly to DXA, using manual soft tissue segmentation, semi-automatic segmentation for the vertebrae, and automatic segmentation for the background. The method was assessed based on repetitive measurements of the standardized European Spine Phantom (ESP) using the standard scout scan tube current (30 mA) and other tube currents (10 to 200 mA), as well as using fat-equivalent extension rings simulating different patient habitus, and was compared to dual-energy X-ray absorptiometry (DXA). Moreover, the feasibility of the method was assessed in vivo in female patients. RESULTS: Derived from standard scout scans, aBMD values measured with the proposed method significantly correlated with DXA measurements (r = 0.9925, p < 0.001), and mean accuracy (DXA, 4.12%; scout, 1.60%) and precision (DXA, 2.64%; scout, 2.03%) were comparable between the two methods. Moreover, aBMD values assessed at different tube currents did not differ significantly (p ≥ 0.20 for all), suggesting that the presented method could be applied to scout scans with different settings. Finally, data derived from sample patients were concordant with BMD values from a reference age-matched population. CONCLUSIONS: Based on dual-layer spectral scout scans, aBMD measurements were fast and reliable and significantly correlated with the according DXA measurements in phantoms. Considering the number of CT acquisitions performed worldwide, this method could allow truly opportunistic osteoporosis screening. KEY POINTS: • 2D scout scans (localizer radiographs) from a dual-layer spectral CT scanner, which are mandatory parts of a CT examination, can be used to automatically determine areal bone mineral density (aBMD) at the spine. • The presented method allowed fast (< 25 s/patient), semi-automatic, and reliable DXA-equivalent aBMD measurements for state-of-the-art DXA phantoms at different tube settings and for various patient habitus, as well as for sample patients. • Considering the number of CT scout scan acquisitions performed worldwide on a daily basis, the presented technique could enable truly opportunistic osteoporosis screening with DXA-equivalent metrics, without involving higher radiation exposure since it only processes existing data that is acquired during each CT scan.


Subject(s)
Bone Density/physiology , Osteoporosis/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Age Factors , Aged , Algorithms , Feasibility Studies , Female , Humans , Image Processing, Computer-Assisted/methods , Middle Aged , Phantoms, Imaging , Reproducibility of Results , Spine/diagnostic imaging , Young Adult
19.
Eur Radiol ; 29(2): 599-608, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30014202

ABSTRACT

OBJECTIVES: Chemical shift encoding-based water-fat MRI derived proton density fat fraction (PDFF) of the paraspinal muscles has been emerging as a surrogate marker in subjects with sarcopenia, lower back pain, injuries and neuromuscular disorders. The present study investigates the performance of paraspinal muscle PDFF and cross-sectional area (CSA) in predicting isometric muscle strength. METHODS: Twenty-six healthy subjects (57.7% women; age: 30 ± 6 years) underwent 3T axial MRI of the lumbar spine using a six-echo 3D spoiled gradient echo sequence for chemical shift encoding-based water-fat separation. Erector spinae and psoas muscles were segmented bilaterally from L2 level to L5 level to determine CSA and PDFF. Muscle flexion and extension maximum isometric torque values [Nm] at the back were measured with an isokinetic dynamometer. RESULTS: Significant correlations between CSA and muscle strength measurements were observed for erector spinae muscle CSA (r = 0.40; p = 0.044) and psoas muscle CSA (r = 0.61; p = 0.001) with relative flexion strength. Erector spinae muscle PDFF correlated significantly with relative muscle strength (extension: r = -0.51; p = 0.008; flexion: r = -0.54; p = 0.005). Erector spinae muscle PDFF, but not CSA, remained a statistically significant (p < 0.05) predictor of relative extensor strength in multivariate regression models (R2adj = 0.34; p = 0.002). CONCLUSIONS: PDFF measurements improved the prediction of paraspinal muscle strength beyond CSA. Therefore, chemical shift encoding-based water-fat MRI may be used to detect subtle changes in the paraspinal muscle composition. KEY POINTS: • We investigated the association of paraspinal muscle fat fraction based on chemical shift encoding-based water-fat MRI with isometric strength measurements in healthy subjects. • Erector spinae muscle PDFF correlated significantly with relative muscle strength. • PDFF measurements improved prediction of paraspinal muscle strength beyond CSA.


Subject(s)
Adipose Tissue/diagnostic imaging , Body Water/diagnostic imaging , Isometric Contraction/physiology , Paraspinal Muscles/diagnostic imaging , Adult , Cross-Sectional Studies , Female , Humans , Low Back Pain/diagnostic imaging , Low Back Pain/physiopathology , Lumbar Vertebrae/anatomy & histology , Lumbar Vertebrae/diagnostic imaging , Magnetic Resonance Imaging/methods , Male , Paraspinal Muscles/anatomy & histology , Paraspinal Muscles/physiology , Protons , Psoas Muscles/anatomy & histology , Psoas Muscles/diagnostic imaging , Psoas Muscles/physiology , Young Adult
20.
AJR Am J Roentgenol ; 213(2): 410-416, 2019 08.
Article in English | MEDLINE | ID: mdl-31039015

ABSTRACT

OBJECTIVE. The purpose of this study was to systematically evaluate image quality, detectability of large-vessel occlusion or dissection, and diagnostic confidence in CT angiography (CTA) with virtually lowered tube current and iterative reconstruction in patients with suspected acute stroke. MATERIALS AND METHODS. Thirty patients (15 with large-vessel occlusion or dissection) underwent CTA of the supraaortal up to the intracranial arterial vessels. CTA scans were simulated as if they were made at 50% (D50), 25% (D25), and 10% (D10) of the original tube current. Image reconstruction was achieved with two levels of iterative reconstruction (A, similar to clinical reconstructions; B, two times stronger regularization). Two readers performed qualitative image evaluation considering overall image quality, artifacts, vessel contrast, detection of vessel abnormalities, and diagnostic confidence. RESULTS. Level B of iterative reconstruction was favorable regarding overall image quality and artifacts for D10, whereas level A was favorable for D100 and D50. CTA scans at D25 and both levels of iterative reconstruction still showed good vessel contrast, with even peripheral arterial branches of the anterior, middle, and posterior cerebral arteries being clearly detectable. Furthermore, CTA scans at D25 and level A of iterative reconstruction showed an adequate level of diagnostic confidence without any missed large-vessel occlusion or dissection according to evaluations by both readers. CONCLUSION. CTA with iterative reconstruction and tube currents decreased to 25% of that for original imaging is feasible without limitations in vessel contrast or detection of vessel abnormalities in patients with suspected acute stroke. Thus, the approach evaluated enables substantial reductions in radiation exposure for patients undergoing head and neck CTA.


Subject(s)
Cerebral Angiography/methods , Computed Tomography Angiography/methods , Radiation Dosage , Stroke/diagnostic imaging , Adult , Aged , Aged, 80 and over , Artifacts , Contrast Media , Female , Humans , Iopamidol/analogs & derivatives , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL