Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 29
Filter
Add more filters

Publication year range
1.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38519418

ABSTRACT

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Subject(s)
Action Potentials , Atrial Fibrillation , Catheter Ablation , Heart Rate , Pulmonary Veins , Recurrence , Registries , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Male , Female , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Middle Aged , Catheter Ablation/adverse effects , Aged , Prospective Studies , Time Factors , Italy , Risk Factors , Heart Atria/physiopathology , Heart Atria/surgery , Treatment Outcome , Progression-Free Survival
2.
Echocardiography ; 41(6): e15849, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38837443

ABSTRACT

Heart failure (HF) is a chronic and progressive disease that often progresses to an advanced stage where conventional therapy is insufficient to relieve patients' symptoms. Despite the availability of advanced therapies such as mechanical circulatory support or heart transplantation, the complexity of defining advanced HF, which requires multiple parameters and multimodality assessment, often leads to delays in referral to dedicated specialists with the result of a worsening prognosis. In this review, we aim to explore the role of cardiac magnetic resonance (CMR) in advanced HF by showing how CMR is useful at every step in managing these patients: from diagnosis to prognostic stratification, hemodynamic evaluation, follow-up and advanced therapies such as heart transplantation. The technical challenges of scanning advanced HF patients, which often require troubleshooting of intracardiac devices and dedicated scans, will be also discussed.


Subject(s)
Heart Failure , Humans , Heart Failure/physiopathology , Heart Failure/diagnosis , Magnetic Resonance Imaging, Cine/methods
3.
J Cardiovasc Electrophysiol ; 34(6): 1386-1394, 2023 06.
Article in English | MEDLINE | ID: mdl-37194742

ABSTRACT

INTRODUCTION: Brugada syndrome (BrS) has a dynamic ECG pattern that might be revealed by certain conditions such as fever. We evaluated the incidence and management of ventricular arrhythmias (VAs) related to COVID-19 infection and vaccination among BrS patients carriers of an implantable loop recorder (ILR) or implantable cardioverter-defibrillator (ICD) and followed by remote monitoring. METHODS: This was a multicenter retrospective study. Patients were carriers of devices with remote monitoring follow-up. We recorded VAs 6 months before COVID-19 infection or vaccination, during infection, at each vaccination, and up to 6-month post-COVID-19 or 1 month after the last vaccination. In ICD carriers, we documented any device intervention. RESULTS: We included 326 patients, 202 with an ICD and 124 with an ILR. One hundred and nine patients (33.4%) had COVID-19, 55% of whom developed fever. Hospitalization rate due to COVID-19 infection was 2.76%. After infection, we recorded only two ventricular tachycardias (VTs). After the first, second, and third vaccines, the incidence of non-sustained ventricular tachycardia (NSVT) was 1.5%, 2%, and 1%, respectively. The incidence of VT was 1% after the second dose. Six-month post-COVID-19 healing or 1 month after the last vaccine, we documented NSVT in 3.4%, VT in 0.5%, and ventricular fibrillation in 0.5% of patients. Overall, one patient received anti-tachycardia pacing and one a shock. ILR carriers had no VAs. No differences were found in VT before and after infection and before and after each vaccination. CONCLUSIONS: From this large multicenter study conducted in BrS patients, followed by remote monitoring, the overall incidence of sustained VAs after COVID-19 infection and vaccination is relatively low.


Subject(s)
Brugada Syndrome , COVID-19 , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Brugada Syndrome/diagnosis , Brugada Syndrome/epidemiology , Brugada Syndrome/therapy , Retrospective Studies , Incidence , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/prevention & control , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/therapy , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/therapy , Registries , Vaccination , Follow-Up Studies
4.
J Cardiovasc Electrophysiol ; 32(8): 2107-2115, 2021 08.
Article in English | MEDLINE | ID: mdl-34216076

ABSTRACT

BACKGROUND: Outcomes of catheter ablation (CA) among patients with nonparoxysmal atrial fibrillation (AF) are largely disappointing. OBJECTIVE: We sought to evaluate the feasibility, effectiveness, and safety of a single-stage stepwise endo-/epicardial approach in patients with persistent/longstanding-persistent AF. METHODS: We enrolled 25 consecutive patients with symptomatic persistent (n = 4) or longstanding-persistent (n = 21) AF and at least one prior endocardial procedure, who underwent CA using an endo-/epicardial approach. Our anatomical stepwise protocol included multiple endocardial as well as epicardial (Bachmann's bundle [BB] and ligament of Marshall ablations) components, and entailed ablation of atrial tachycardias emerging during the procedure. The primary outcome was freedom from any AF/atrial tachycardia episode after a 3-month blanking period. The secondary outcome was patients' symptom status during follow-up. RESULTS: The stepwise endo-/epicardial approach allowed sinus rhythm restoration in 72% of patients, either directly (n = 6, 24%) or after AF organization into atrial tachycardia (n = 12, 48%). BB's ablation was commonly implicated in arrhythmia termination. After a median follow-up of 266 days (interquartile range, 96 days), survival free from AF/atrial tachycardia was 88%. Antiarrhythmic drugs could be discontinued in 22 patients (88%). As compared to baseline, more patients were asymptomatic at 9-month follow-up (0% vs. 56%, p = .02). Five patients (20%) developed mild medical complications, whereas one subject (4%) had severe kidney injury requiring dialysis. CONCLUSION: A single-stage endo-/epicardial CA resulted in favorable rhythm and symptom outcomes in a cohort of patients with symptomatic persistent/longstanding-persistent AF and one or more prior endocardial procedures. Epicardial ablation of BB was commonly implicated in procedural success.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Humans , Mediterranea , Recurrence , Treatment Outcome
5.
J Cardiovasc Electrophysiol ; 32(6): 1695-1703, 2021 06.
Article in English | MEDLINE | ID: mdl-33969578

ABSTRACT

BACKGROUND: The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation involves three incisions and a subcutaneous (SC) pocket. An intermuscular (IM) 2-incision technique has been recently adopted. AIMS: We assessed acute defibrillation efficacy (DE) of S-ICD (DE ≤65 J) according to the implantation technique. METHODS: We analyzed consecutive patients who underwent S-ICD implantation and DE testing at 53 Italian centers. Regression analysis was used to determine the association between DFT and implantation technique. RESULTS: A total of 805 patients were enrolled. Four groups were assessed: IM + 2 incisions (n = 546), SC + 2 incisions (n = 133), SC + 3 incisions (n = 111), and IM + 3 incisions (n = 15). DE was ≤65 J in 782 (97.1%) patients. Patients with DE ≤65 J showed a trend towards lower body mass index (25.1 vs. 26.5; p = .12), were less frequently on antiarrhythmic drugs (13% vs. 26%; p = .06) and more commonly underwent implantation with the 2-incision technique (85% vs. 70%; p = .04). The IM + 2-incision technique showed the lowest defibrillation failure rate (2.2%) and shock impedance (66 Ohm, interquartile range: 57-77). On multivariate analysis, the 2-incision technique was associated with a lower incidence of shock failure (hazard ratio: 0.305; 95% confidence interval: 0.102-0.907; p = .033). Shock impedance was lower with the IM than with the SC approach (66 vs. 70 Ohm p = .002) and with the 2-incision than the 3-incision technique (67 vs. 72 Ohm; p = .006). CONCLUSIONS: In a large population of S-ICD patients, we observed a high defibrillation success rate. The IM + 2-incision technique provides lower shock impedance and a higher likelihood of successful defibrillation.


Subject(s)
Defibrillators, Implantable , Body Mass Index , Electric Countershock/adverse effects , Electric Impedance , Humans , Prosthesis Implantation/adverse effects , Subcutaneous Tissue , Treatment Outcome
7.
J Cardiovasc Electrophysiol ; 26(8): 819-825, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25884325

ABSTRACT

BACKGROUND: This study examined incidence of AF following cavotricuspid isthmus (CTI) ablation alone or CTI plus prophylactic pulmonary vein isolation (PVI) in patients presenting with isolated atrial flutter (AFL) with no history of AF. METHODS AND RESULTS: We enrolled 216 patients with isolated typical atrial flutter and randomized them to CTI alone (group 1, n = 108, 61.2 ± 9.7 year, 75% male) or CTI+PVI ablation (group 2, n = 108, 62.4 ± 9.3 year, 73% male). Insertible loop recorder (ILR) was implanted in 21 and 19 patients from groups 1 and 2, respectively. Remaining patients were monitored with event recorders, ECG, 7-day Holter. Follow-up period was for 18 ± 6 months. Compared to group 1, group 2 had significantly longer procedural duration (75.9 ± 33 min vs. 161 ± 48 min [P < 0.001]) and fluoroscopy time (15.9 ± 12.3 min vs. 56.4+21 min [P < 0.001]). At the end of follow-up, 65 (60.2%) in group 1 and 77 (71.3%) in group 2 were arrhythmia free off-AAD (log-rank P = 0.044). A subgroup analysis was performed with 55 year age cut-off. In the <55 age group the CTI only population had similar success as in CTI+PVI, (21 of 24 [83.3%] vs. 19 of 22 [86.4%], respectively, log-rank P = 0.74). In the ≥55 group, having CTI+PVI showed significantly higher success compared to CTI only; 45 of 84 (53.6%) were AF/AT free in CTI only group versus 58 of 86 (67.4%) with CTI+PVI (log-rank P = 0.029). CONCLUSION: Prophylactic PVI reduced new-onset AF in patients with lone atrial flutter.


Subject(s)
Atrial Fibrillation/prevention & control , Atrial Flutter/surgery , Catheter Ablation/methods , Pulmonary Veins/surgery , Action Potentials , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Atrial Flutter/diagnosis , Atrial Flutter/epidemiology , Atrial Flutter/physiopathology , Catheter Ablation/adverse effects , Disease-Free Survival , Electrocardiography, Ambulatory , Female , Heart Rate , Humans , Incidence , Italy/epidemiology , Kaplan-Meier Estimate , Male , Middle Aged , Pilot Projects , Proportional Hazards Models , Pulmonary Veins/physiopathology , Risk Factors , Telemetry , Time Factors , Treatment Outcome , United States/epidemiology
8.
J Cardiovasc Electrophysiol ; 25(8): 824-833, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24724831

ABSTRACT

INTRODUCTION: It is unclear whether extended pulmonary vein antrum isolation (PVAI) plus nonpulmonary vein (non-PV) trigger elimination prevents more arrhythmia recurrence than PVAI alone in patients with mechanical mitral valve (MMV) undergoing AF ablation. This study compared the efficacy and long-term outcome of 2 ablation strategies--PVAI alone versus extended PVAI plus non-PV trigger elimination--for the treatment of AF in patients with MMV. METHODS AND RESULTS: One hundred and nine consecutive AF patients with MMV were divided into 2 groups: standard PVAI was performed in group 1 (N = 45); in group 2 (N = 64) PVAI was extended to the LA posterior wall, LA septum, and CS; and all non-PV triggers were eliminated. Patients were followed up for 3 years. At the 12th month, 7 (15.6%) patients in group 1, and 39 (60.9%) patients in group 2 were arrhythmia free (log-rank P < 0.001). Four patients (8.9%; 3 cases of AT and 1 case of AF) from group 1, and 12 patients (18.8%; 9 cases of AT, and 3 cases of AFL) from group 2 experienced very late recurrence. At 36 ± 7 months follow-up, the cumulative recurrence after a single procedure was 42/45 (93.3%) in group 1, and 37/64 (57.8%) in group 2 (log-rank P < 0.001). CONCLUSION: Compared with the standard PVAI alone, a strategy including extended PVAI and non-PV trigger elimination is associated with a higher 12-month and long-term arrhythmia-free survival in patients with MMV undergoing AF ablation. Very late recurrence may occur years after the initial procedure with focal AT as the most common type of recurrent arrhythmia.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Valve Prosthesis Implantation/instrumentation , Mitral Valve/surgery , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/etiology , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , China , Disease-Free Survival , Electrophysiologic Techniques, Cardiac , Europe , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Mitral Valve/physiopathology , Prosthesis Design , Pulmonary Veins/physiopathology , Recurrence , Risk Factors , Time Factors , Treatment Outcome , United States
9.
Int J Cardiol Heart Vasc ; 51: 101391, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38560514

ABSTRACT

Background: Transcatheter left atrial appendage occlusion (LAAO) has emerged as an alternative treatment for stroke prevention in patients with atrial fibrillation (AF) at high risk of thromboembolism, who cannot tolerate long-term oral anticoagulation (OAC). Questions persist regarding effectiveness and safety of this treatment and the optimal post-interventional antithrombotic regimen after LAAO. Methods: We retrospectively gathered data from 428 patients who underwent percutaneous LAAO in 6 Italian high-volume centres, aimed at describing the real-world utilization, safety, and effectiveness of LAAO procedures, also assessing the clinical outcomes associated with different antithrombotic strategies. Results: Among the entire population, 20 (4.7 %) patients experienced a combination of pericardial effusion and periprocedural major bleeding: 8 (1.9 %) pericardial effusion, 1 (0.3 %) fatal bleeding, and 3 (0.7 %) non-fatal procedural major bleeding. Patients were discharged with different antithrombotic regimens: dual (DAPT) (27 %) or single (SAPT) (26 %) antiplatelet therapy, OAC (27 %), other antithrombotic regimens (14 %). Very few patients were not prescribed with antithrombotic drugs (6 %). At a medium 523 ± 58 days follow-up, 14 patients (3.3 %) experienced all-cause death, 6 patients (1.4 %) cardiovascular death, 3 patients (0.7 %) major bleeding, 10 patients (2.6 %) clinically relevant non-major bleeding, and 3 patients (0.7 %) ischemic stroke. At survival analysis, with DAPT as the reference group, OAC therapy was associated with better outcomes. Conclusions: Our findings confirm that LAAO is a safe procedure. Different individualized post-discharge antithrombotic regimens are now adopted, likely driven by the perceived thrombotic and hemorrhagic risk. The incidence of both ischemic and bleeding events tends to be low.

10.
JACC Clin Electrophysiol ; 10(4): 709-715, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38310489

ABSTRACT

BACKGROUND: High-voltage pulses can cause hemolysis. OBJECTIVES: The authors evaluated the occurrence of hemoglobinuria after pulsed-field ablation (PFA) and its impact on renal function in patients with atrial fibrillation (AF). METHODS: A consecutive series of patients with AF undergoing PFA were included in this analysis. The initial patients who did not receive postablation hydration immediately after the procedure were classified as group 1 (n = 28), and the rest of the study patients who received planned fluid infusion (0.9% sodium chloride ≥2 L) after the procedure were categorized as group 2 (n = 75). RESULTS: Of the 28 patients in group 1, 21 (75%) experienced hemoglobinuria during the 24 hours after catheter ablation. The mean postablation serum creatinine (S-Cr) was significantly higher than the baseline value in those 21 patients (1.46 ± 0.28 mg/dL vs 0.86 ± 0.24 mg/dL, P < 0.001). Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 ± 0.21 mg/dL). The mean number of PF applications was significantly higher in those 4 patients than in the other 17 patients experiencing hemoglobinuria (94.63 ± 3.20 vs 46.75 ± 9.10, P < 0.001). In group 2 patients, no significant changes in S-Cr were noted. The group 2 patients received significantly higher amounts of fluid infusion after catheter ablation than did those in group 1 (2,082.50 ± 258.08 mL vs 494.01 ± 71.65 mL, P < 0.001). In multivariable analysis, both hydration (R2 = 0.63, P < 0.01) and number of PFA applications (R2 = 0.33, P < 0.01) were independent predictors of postprocedure acute kidney injury. CONCLUSIONS: On the basis of our findings, both the number of PFA applications and postablation hydration were independent predictors of renal insult that could be prevented using planned fluid infusion immediately after the procedure.


Subject(s)
Acute Kidney Injury , Atrial Fibrillation , Catheter Ablation , Hemoglobinuria , Humans , Atrial Fibrillation/surgery , Male , Female , Catheter Ablation/adverse effects , Catheter Ablation/methods , Middle Aged , Acute Kidney Injury/prevention & control , Acute Kidney Injury/etiology , Aged , Hemoglobinuria/etiology , Hemoglobinuria/prevention & control , Creatinine/blood , Retrospective Studies , Postoperative Complications/prevention & control , Postoperative Complications/etiology , Fluid Therapy/methods
11.
JACC Clin Electrophysiol ; 9(3): 314-326, 2023 03.
Article in English | MEDLINE | ID: mdl-36752480

ABSTRACT

BACKGROUND: Endomyocardial biopsy (EMB) is required to make a definite diagnosis of lymphocytic myocarditis (LM), to identify its etiology, and to classify LM into different phases. OBJECTIVES: This study aims to characterize and compare clinical and electrophysiological characteristics of different biopsy-proven LM phases, namely acute myocarditis (AM), chronic active myocarditis (CAM), and healed myocarditis (HM). METHODS: All patients with a diagnosis of LM at 3 Italian referral centers were prospectively enrolled. According to EMB findings, LM was classified as AM, CAM, or HM; per-group comparisons of clinical presentations, noninvasive, and invasive findings are reported. RESULTS: Among the 122 enrolled patients (AM, n = 44; CAM, n = 42; HM, n = 36), complex ventricular arrhythmias were very common overall (n = 109, 89%), but ventricular fibrillation was slightly more prevalent in AM (P = 0.028). Cardiac magnetic resonance imaging showed late gadolinium enhancement in more patients with HM and CAM than AM (94.4% vs 92.9% vs 50%; P < 0.001), whereas edema was more common in AM than in CAM, being absent in HM (90.9% vs 50% vs 0%; P < 0.001). Accordingly, edema was the strongest independent clinical predictor of EMB-proven active inflammation. Electroanatomical mapping revealed a lower prevalence of low-voltage areas in AM than in CAM or HM. We observed a strong association between edema at a specific myocardial segment and normal voltages at that site (odds ratio: 0.24; 95% CI: 0.10-0.54; P < 0.01), as well as between late gadolinium enhancement and low-voltage areas (odds ratio: 2.86; 95% CI: 1.19-6.97; P = 0.019). CONCLUSIONS: LM is a highly heterogeneous disease, and its different phases are characterized by diverse clinical, morphological, and electrophysiological features. Further research is required to identify electroanatomical markers of inflammation.


Subject(s)
Myocarditis , Humans , Myocarditis/complications , Myocarditis/diagnosis , Contrast Media , Gadolinium , Myocardium/pathology , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/etiology , Inflammation
12.
Heart Rhythm ; 20(3): 395-404, 2023 03.
Article in English | MEDLINE | ID: mdl-36496135

ABSTRACT

BACKGROUND: Limited data on the real-world safety and efficacy of leadless pacemakers (LPMs) post-transvenous lead extraction (TLE) are available. OBJECTIVE: The purpose of this study was to assess the long-term safety and effectiveness of LPMs following TLE in comparison with LPMs de novo implantation. METHODS: Consecutive patients who underwent LPM implantation in 12 European centers joining the International LEAdless PacemakEr Registry were enrolled. The primary end point was the comparison of LPM-related complication rate at implantation and during follow-up (FU) between groups. Differences in electrical performance were deemed secondary outcomes. RESULTS: Of the 1179 patients enrolled, 15.6% underwent a previous TLE. During a median FU of 33 (interquartile range 24-47) months, LPM-related major complications and all-cause mortality did not differ between groups (TLE group: 1.6% and 5.4% vs de novo group: 2.2% and 7.8%; P = .785 and P = .288, respectively). Pacing threshold (PT) was higher in the TLE group at implantation and during FU, with very high PT (>2 V@0.24 ms) patients being more represented than in the de novo implantation group (5.4% vs 1.6 %; P = .004). When the LPM was deployed at a different right ventricular (RV) location than the one where the previous transvenous RV lead was extracted, a lower proportion of high PT (>1-2 V@0.24 ms) patients at implantation, 1-month FU, and 12-month FU (5.9% vs 18.2%, P = .012; 3.4% vs 12.9%, P = .026; and 4.3% vs 14.5%, P = .037, respectively) was found. CONCLUSION: LPMs showed a satisfactory safety and efficacy profile after TLE. Better electrical parameters were obtained when LPMs were implanted at a different RV location than the one where the previous transvenous RV lead was extracted.


Subject(s)
Pacemaker, Artificial , Humans , Treatment Outcome , Pacemaker, Artificial/adverse effects , Cardiac Pacing, Artificial/adverse effects , Registries , Equipment Design
13.
Heart Rhythm ; 20(2): 233-240, 2023 02.
Article in English | MEDLINE | ID: mdl-37283031

ABSTRACT

BACKGROUND: Elevated resting heart rate is a risk factor for cardiovascular events. OBJECTIVE: The purpose of this study was to investigate the clinical significance of nocturnal heart rate (nHR) and 24-hour mean heart rate (24h-HR) obtained by continuous remote monitoring (RM) of implantable devices. METHODS: We analyzed daily-sampled trends of nHR, 24h-HR, and physical activity in patients on ß-blocker therapy for chronic heart failure and with implantable cardioverter-defibrillators or cardiac resynchronization therapy defibrillators (CRT-Ds). Patients were grouped by average nHR and 24h-HR quartile during follow-up to estimate the respective incidence of nonarrhythmic death and device-treated ventricular tachycardia/fibrillation (VT/VF). RESULTS: The study cohort included 1330 patients (median age 69 years [interquartile range 61-77 years]; 41% [n = 550] with CRT-D; median follow-up 25 months [interquartile range 13-42 months]). Compared with patients in the lowest nHR quartile (≤57 beats/min) group, patients in the highest quartile group (>65 beats/min) had an increased risk of nonarrhythmic death (adjusted hazard ratio [AHR] 2.25; 95% confidence interval [CI] 1.13-4.50; P = .021) and VT/VF (AHR 1.98; 95% CI 1.40-2.79; P < .001) and were characterized by the lowest level of physical activity (P ≤ .0004 vs every other nHR quartiles). The highest 24h-HR quartile group (>75 beats/min) showed an increased risk of VT/VF (AHR 2.13; 95% CI 1.52-2.99; P < .001) and a weaker though significant association with nonarrhythmic mortality (AHR 1.80; 95% CI 1.00-3.22; P = .05) as compared with the lowest 24h-HR quartile group (≤65 beats/min). CONCLUSION: In remotely monitored patients with implantable cardioverter-defibrillator/CRT-D on ß-blocker therapy for heart failure, elevated heart rates (nHR >65 beats/min and 24h-HR >75 beats/min) were associated with increased mortality and VT/VF risk. nHR showed a stronger association than 24h-HR with worst prognosis and lowest physical activity.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Tachycardia, Ventricular , Ventricular Dysfunction, Left , Humans , Middle Aged , Aged , Heart Rate , Prognosis , Stroke Volume , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/therapy , Ventricular Fibrillation/therapy , Arrhythmias, Cardiac/therapy , Risk Factors , Heart Failure/complications , Heart Failure/diagnosis , Heart Failure/therapy , Cardiac Resynchronization Therapy/adverse effects , Defibrillators, Implantable/adverse effects , Ventricular Dysfunction, Left/complications
14.
JACC Clin Electrophysiol ; 9(12): 2615-2627, 2023 12.
Article in English | MEDLINE | ID: mdl-37768253

ABSTRACT

BACKGROUND: Electrocardiographic (ECG) findings in arrhythmogenic left ventricular cardiomyopathy (ALVC) are limited to small case series. OBJECTIVES: This study aimed to analyze the ECG characteristics of ALVC patients and to correlate ECG with cardiac magnetic resonance and genotype data. METHODS: We reviewed data of 54 consecutive ALVC patients (32 men, age 39 ± 15 years) and compared them with 84 healthy controls with normal cardiac magnetic resonance. RESULTS: T-wave inversion was often noted (57.4%), particularly in the inferior and lateral leads. Low QRS voltages in limb leads were observed in 22.2% of patients. The following novel ECG findings were identified: left posterior fascicular block (LPFB) (20.4%), pathological Q waves (33.3%), and a prominent R-wave in V1 with a R/S ratio ≥0.5 (24.1%). The QRS voltages were lower in ALVC compared with controls, particularly in lead I and II. At receiver-operating characteristic analysis, the sum of the R-wave in I to II ≤8 mm (AUC: 0.909; P < 0.0001) and S-wave in V1 plus R-wave in V6 ≤12 mm (AUC: 0.784; P < 0.0001) effectively discriminated ALVC patients from controls. It is noteworthy that 4 of the 8 patients with an apparently normal ECG were recognized by these new signs. Transmural late gadolinium enhancement was associated to LPFB, a R/S ratio ≥0.5 in V1, and inferolateral T-wave inversion, and a ringlike pattern correlated to fragmented QRS, SV1+RV6 ≤12 mm, low QRS voltage, and desmoplakin alterations. CONCLUSIONS: Pathological Q waves, LPFB, and a prominent R-wave in V1 were common ECG signs in ALVC. An R-wave sum in I to II ≤8 mm and SV1+RV6 ≤12 mm were specific findings for ALVC phenotypes compared with controls.


Subject(s)
Cardiomyopathies , Contrast Media , Male , Humans , Young Adult , Adult , Middle Aged , Gadolinium , Electrocardiography , Arrhythmias, Cardiac , Bundle-Branch Block
15.
J Cardiovasc Echogr ; 32(4): 222-224, 2022.
Article in English | MEDLINE | ID: mdl-36994119

ABSTRACT

Papillary fibroelastomas (PFs) are small and pedunculated left side valves associated mass, that frequently causing cerebral embolization. We present the case of a 69-year-old male with a history of multiple ischemic strokes and a small pedunculated mass in the left ventricle outflow tract, highly suggestive of a rare case of PF in an atypical localization. Due to the clinical history and the echocardiographic aspect of the mass, he underwent surgical excision and Bentall intervention for concomitant aortic root and ascending aorta aneurysm. The pathological analysis of the surgical specimen confirmed the diagnosis of PF.

16.
Card Electrophysiol Clin ; 14(3): 357-373, 2022 09.
Article in English | MEDLINE | ID: mdl-36153119

ABSTRACT

Atrial flutter (AFL) is a regular supraventricular reentrant tachycardia generating a continuous fluttering of the baseline electrocardiography (ECG) at a rate of 250 to 300 beats per minute. AFL is classified based on the involvement of the cavo-tricuspid isthmus in the circuit. The "isthmic" (or type 1) AFL develops entirely in the right atrium; this circuit is commonly activated in a counter-clockwise direction, generating the common sawtooth ECG morphology in the inferior leads (slow descendent-fast ascendent). AFL can be nonisthmus dependent (type 2), often presenting with faster atrial rate and most commonly a left atrial location.


Subject(s)
Atrial Flutter , Catheter Ablation , Atrial Flutter/surgery , Cardiac Electrophysiology , Electrocardiography , Heart Atria , Humans
17.
Card Electrophysiol Clin ; 14(3): 385-399, 2022 09.
Article in English | MEDLINE | ID: mdl-36153121

ABSTRACT

Atrial flutter (AFL) is a macro-reentrant arrhythmia characterized, in a 12 lead ECG, by the continuous oscillation of the isoelectric line in at least one lead. In the typical form of AFL, the oscillation is most obvious in the inferior leads, due to a macro-reentrant circuit localized in the right atrium, with the cavo-tricuspid isthmus as a critical zone.: This circuit can be activated in a counterclockwise or clockwise direction generating in II, III, and aVF leads, respectively, a slow descending/fast ascending F wave pattern (common form of typical AFL) or a balanced ascending/descending waveform (uncommon form of typical AFL). Atypical AFLs (scar-related) do not include the CTI in the circuit and show an extremely variable circuit location and ECG morphology.


Subject(s)
Atrial Flutter , Catheter Ablation , Diagnosis, Differential , Electrocardiography , Heart Atria , Humans
18.
Card Electrophysiol Clin ; 14(3): 517-532, 2022 09.
Article in English | MEDLINE | ID: mdl-36153131

ABSTRACT

"Despite being one of the best understood cardiac arrhythmias, the clinical meaning of atrial flutter varies according to the specific context, and its optimal treatment may be limited by both the suboptimal response to rate/rhythm control drugs and by the complexity of the underlying substrate. In this article, we present a state-of-the-art overview of mechanisms, prognostic impact, and medical/interventional management options for atrial flutter in several specific patient populations, including heart failure, cardiomyopathies, muscular dystrophies, posttransplant patients, patients with respiratory disorders, athletes, and subjects with preexcitation, aiming to stimulate further research in this challenging field and facilitate appropriate patient care."


Subject(s)
Atrial Fibrillation , Atrial Flutter , Cardiomyopathies , Catheter Ablation , Atrial Fibrillation/surgery , Humans
19.
Heart Rhythm ; 19(5): 790-797, 2022 05.
Article in English | MEDLINE | ID: mdl-35066184

ABSTRACT

BACKGROUND: In heart failure (HF) patients, atrial fibrillation (AF) is associated with a worse prognosis. Implantable cardioverter-defibrillator (ICD) diagnostics allow continuous monitoring of AF and are equipped with algorithms for HF monitoring. OBJECTIVE: We evaluated the association between the values of the multisensor HF HeartLogic index and the incidence of AF, and assessed the performance of the index in detecting follow-up periods of significantly increased AF risk. METHODS: The HeartLogic feature was activated in 568 ICD patients. Median follow-up was 25 months [25th-75th percentile (15-35)]. The HeartLogic algorithm calculates a daily HF index and identifies periods of IN-alert state on the basis of a configurable threshold. The endpoints were daily AF burden ≥5 minutes, ≥6 hours, and ≥23 hours. RESULTS: The HeartLogic index crossed the threshold value 1200 times. AF burden ≥5 minutes/day was documented in 183 patients (32%), ≥6 hours/day in 118 patients (21%), and ≥23 hours/day in 89 patients (16%). The weekly time of IN-alert state was independently associated with AF burden ≥5 minutes/day (hazard ratio [HR] 1.95; 95% confidence interval [CI] 1.22-3.13; P = .005), ≥6 hours/day (HR 2.66; 95% CI 1.60-4.44; P <.001), and ≥23 hours/day (HR 3.32; 95% CI 1.83-6.02; P <.001), after correction for baseline confounders. Comparison of the episode rates in the IN-alert state with those in the OUT-of-alert state yielded HR ranging from 1.57 to 3.11 for AF burden from ≥5 minutes to ≥23 hours. CONCLUSIONS: The HeartLogic alert state was independently associated with AF occurrence. The intervals of time defined by the algorithm as periods of increased risk of HF allow risk stratification of AF according to various thresholds of daily burden.


Subject(s)
Atrial Fibrillation , Defibrillators, Implantable , Heart Failure , Algorithms , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Heart Failure/complications , Heart Failure/diagnosis , Heart Failure/therapy , Humans , Monitoring, Physiologic
20.
J Interv Card Electrophysiol ; 64(3): 607-619, 2022 Sep.
Article in English | MEDLINE | ID: mdl-34709504

ABSTRACT

PURPOSE: The purpose of this study was to assess the available mortality risk stratification models for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRT-D) patients. METHODS: We conducted a review of mortality risk stratification models and tested their ability to improve prediction of 1-year survival after implant in a database of patients who received a remotely controlled ICD/CRT-D device during routine care and included in the independent Home Monitoring Expert Alliance registry. RESULTS: We identified ten predicting models published in peer-reviewed journals between 2000 and 2021 (Parkash, PACE, MADIT, aCCI, CHA2DS2-VASc quartiles, CIDS, FADES, Sjoblom, AAACC, and MADIT-ICD non-arrhythmic mortality score) that could be tested in our database as based on common demographic, clinical, echocardiographic, electrocardiographic, and laboratory variables. Our cohort included 1,911 patients with left ventricular dysfunction (median age 71, 18.3% female) from sites not using any risk stratification score for systematic patient screening. Patients received an ICD (53.8%) or CRT-D (46.2%) between 2011 and 2017, after standard physician evaluation. There were 56 deaths within 1-year post-implant, with an all-cause mortality rate of 2.9% (95% confidence interval [CI], 2.3-3.8%). Four predicting models (Parkash, MADIT, AAACC, and MADIT-ICD non-arrhythmic mortality score) were significantly associated with increased risk of 1-year mortality with hazard ratios ranging from 3.75 (CI, 1.31-10.7) to 6.53 (CI 1.52-28.0, p ≤ 0.014 for all four). Positive predictive values of 1-year mortality were below 25% for all models. CONCLUSION: In our analysis, the models we tested conferred modest incremental predicting power to ordinary screening methods.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Cardiac Resynchronization Therapy/methods , Cardiac Resynchronization Therapy Devices/adverse effects , Defibrillators, Implantable/adverse effects , Female , Heart Failure/therapy , Humans , Male , Risk Assessment , Risk Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL