1.
Microcirculation ; 30(5-6): e12820, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37392132

ABSTRACT

OBJECTIVE: Recent advances in tissue clearing and high-throughput imaging have enabled the acquisition of extended-volume microvasculature images at a submicron resolution. The objective of this study was to extract information from this type of images by integrating a sequence of 3D image processing steps on Terabyte scale datasets. METHODS: We acquired coronary microvasculature images throughout an entire short-axis slice of a 3-month-old Wistar-Kyoto rat heart. This dataset covered 13 × 10 × 0.6 mm at a resolution of 0.933 × 0.933 × 1.866 µm and occupied 700 Gigabytes of disk space. We used chunk-based image segmentation, combined with an efficient graph generation technique, to quantify the microvasculature in the large-scale images. Specifically, we focused on the microvasculature with a vessel diameter up to 15 µm. RESULTS: Morphological data for the complete short-axis ring were extracted within 16 h using this pipeline. From the analyses, we identified that microvessel lengths in the rat coronary microvasculature varied from 6 to 300 µm. However, their distribution was heavily skewed toward shorter lengths, with a mode of 16.5 µm. In contrast, vessel diameters ranged from 3 to 15 µm and had an approximately normal distribution of 6.5 ± 2 µm. CONCLUSION: The tools and techniques from this study will serve other investigations into the microcirculation, and the wealth of data from this study will enable the analysis of biophysical mechanisms using computer models.

2.
Dig Dis Sci ; 68(10): 3953-3962, 2023 10.
Article in English | MEDLINE | ID: mdl-37587256

ABSTRACT

BACKGROUND: Radio-frequency ablation of gastric tissue is in its infancy compared to its extensive history and use in the cardiac field. AIMS: We employed power-controlled, irrigated radio-frequency ablation to create lesions on the serosal surface of the stomach to examine the impact of ablation power, irrigation, temperature, and impedance on lesion formation and tissue damage. METHODS: A total of 160 lesions were created in vivo in female weaner pigs (n = 5) using a combination of four power levels (10, 15, 20, 30 W) at two irrigation rates (2, 5 mL min-1) and with one temperature-controlled (65 °C) reference setting previously validated for electrophysiological intervention in the stomach. RESULTS: Power and irrigation rate combinations above 15 W resulted in lesions with significantly higher surface area and depth than the temperature-controlled setting. Irrigation resulted in significantly lower temperature (p < 0.001) and impedance (p < 0.001) compared to the temperature-controlled setting. No instances of perforation or tissue pop were recorded for any ablation sequence. CONCLUSION: Power-controlled, irrigated radio-frequency ablation of gastric tissue is effective in creating larger and deeper lesions at reduced temperatures than previously investigated temperature-controlled radio-frequency ablation, highlighting a substantial improvement. These data define the biophysical impact of ablation parameters in gastric tissue, and they will guide future translation toward clinical application and in silico gastric ablation modeling. Combination of ablation settings (10-30 W power, 2-5 mL min-1 irrigation) were used to create serosal spot lesions. Histological analysis of lesions quantified localized tissue damage.


Subject(s)
Catheter Ablation , Radiofrequency Ablation , Female , Animals , Swine , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart , Body Temperature/physiology , Stomach/surgery , Therapeutic Irrigation , Equipment Design
3.
J Physiol ; 600(18): 4119-4135, 2022 09.
Article in English | MEDLINE | ID: mdl-35984854

ABSTRACT

Hypertensive heart disease (HHD) increases risk of ventricular tachycardia (VT) and ventricular fibrillation (VF). The roles of structural vs. electrophysiological remodelling and age vs. disease progression are not fully understood. This cross-sectional study of cardiac alterations through HHD investigates mechanistic contributions to VT/VF risk. Risk was electrically assessed in Langendorff-perfused, spontaneously hypertensive rat hearts at 6, 12 and 18 months, and paced optical membrane voltage maps were acquired from the left ventricular (LV) free wall epicardium. Distributions of LV patchy fibrosis and 3D cellular architecture in representative anterior LV mid-wall regions were quantified from macroscopic and microscopic fluorescence images of optically cleared tissue. Imaging showed increased fibrosis from 6 months, particularly in the inner LV free wall. Myocyte cross-section increased at 12 months, while inter-myocyte connections reduced markedly with fibrosis. Conduction velocity decreased from 12 months, especially transverse to the myofibre direction, with rate-dependent anisotropy at 12 and 18 months, but not earlier. Action potential duration (APD) increased when clustered by age, as did APD dispersion at 12 and 18 months. Among 10 structural, functional and age variables, the most reliably linked were VT/VF risk, general LV fibrosis, a measure quantifying patchy fibrosis, and non-age clustered APD dispersion. VT/VF risk related to a quantified measure of patchy fibrosis, but age did not factor strongly. The findings are consistent with the notion that VT/VF risk is associated with rate-dependent repolarization heterogeneity caused by structural remodelling and reduced lateral electrical coupling between LV myocytes, providing a substrate for heterogeneous intramural activation as HHD progresses. KEY POINTS: There is heightened arrhythmic risk with progression of hypertensive heart disease. Risk is related to increasing left ventricular fibrosis, but the nature of this relationship has not been quantified. This study is a novel systematic characterization of changes in active electrical properties and fibrotic remodelling during progression of hypertensive heart disease in a well-established animal disease model. Arrhythmic risk is predicted by several left ventricular measures, in particular fibrosis quantity and structure, and epicardial action potential duration dispersion. Age alone is not a good predictor of risk. An improved understanding of links between arrhythmic risk and fibrotic architectures in progressive hypertensive heart disease aids better interpretation of late gadolinium-enhanced cardiac magnetic resonance imaging and electrical mapping signals.


Subject(s)
Tachycardia, Ventricular , Action Potentials/physiology , Animals , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/etiology , Cross-Sectional Studies , Fibrosis , Multimodal Imaging/adverse effects , Pericardium , Rats , Rats, Inbred SHR , Tachycardia, Ventricular/etiology , Ventricular Fibrillation
4.
Am J Physiol Gastrointest Liver Physiol ; 323(6): G640-G652, 2022 12 01.
Article in English | MEDLINE | ID: mdl-36255716

ABSTRACT

Gastric ablation has demonstrated potential to induce conduction blocks and correct abnormal electrical activity (i.e., ectopic slow-wave propagation) in acute, intraoperative in vivo studies. This study aimed to evaluate the safety and feasibility of gastric ablation to modulate slow-wave conduction after 2 wk of healing. Chronic in vivo experiments were performed in weaner pigs (n = 6). Animals were randomly divided into two groups: sham-ablation (n = 3, control group; no power delivery, room temperature, 5 s/point) and radiofrequency (RF) ablation (n = 3; temperature-control mode, 65°C, 5 s/point). In the initial surgery, high-resolution serosal electrical mapping (16 × 16 electrodes; 6 × 6 cm) was performed to define the baseline slow-wave activation profile. Ablation (sham/RF) was then performed in the mid-corpus, in a line around the circumferential axis of the stomach, followed by acute postablation mapping. All animals recovered from the procedure, with no sign of perforation or other complications. Two weeks later, intraoperative high-resolution mapping was repeated. High-resolution mapping showed that ablation successfully induced sustained conduction blocks in all cases in the RF-ablation group at both the acute and 2 wk time points, whereas all sham-controls had no conduction block. Histological and immunohistochemical evaluation showed that after 2 wk of healing, the lesions were in the inflammation and early proliferation phase, and interstitial cells of Cajal (ICC) were depleted and/or deformed within the ablation lesions. This safety and feasibility study demonstrates that gastric ablation can safely and effectively induce a sustained localized conduction block in the stomach without disrupting the surrounding slow-wave conduction capability.NEW & NOTEWORTHY Ablation has recently emerged as a tool for modulating gastric electrical activation and may hold interventional potential for disorders of gastric function. However, previous studies have been limited to the acute intraoperative setting. This study now presents the safety of gastric ablation after postsurgical recovery and healing. Localized electrical conduction blocks created by ablation remained after 2 wk of healing, and no perforation or other complications were observed over the postsurgical period.


Subject(s)
Catheter Ablation , Interstitial Cells of Cajal , Animals , Catheter Ablation/adverse effects , Feasibility Studies , Interstitial Cells of Cajal/physiology , Serous Membrane , Stomach/physiology , Swine
5.
Am J Physiol Heart Circ Physiol ; 323(2): H257-H275, 2022 08 01.
Article in English | MEDLINE | ID: mdl-35657613

ABSTRACT

The complex and highly organized structural arrangement of some five billion cardiomyocytes directs the coordinated electrical activity and mechanical contraction of the human heart. The characteristic transmural change in cardiomyocyte orientation underlies base-to-apex shortening, circumferential shortening, and left ventricular torsion during contraction. Individual cardiomyocytes shorten ∼15% and increase in diameter ∼8%. Remarkably, however, the left ventricular wall thickens by up to 30-40%. To accommodate this, the myocardium must undergo significant structural rearrangement during contraction. At the mesoscale, collections of cardiomyocytes are organized into sheetlets, and sheetlet shear is the fundamental mechanism of rearrangement that produces wall thickening. Herein, we review the histological and physiological studies of myocardial mesostructure that have established the sheetlet shear model of wall thickening. Recent developments in tissue clearing techniques allow for imaging of whole hearts at the cellular scale, whereas magnetic resonance imaging (MRI) and computed tomography (CT) can image the myocardium at the mesoscale (100 µm to 1 mm) to resolve cardiomyocyte orientation and organization. Through histology, cardiac diffusion tensor imaging (DTI), and other modalities, mesostructural sheetlets have been confirmed in both animal and human hearts. Recent in vivo cardiac DTI methods have measured reorientation of sheetlets during the cardiac cycle. We also examine the role of pathological cardiac remodeling on sheetlet organization and reorientation, and the impact this has on ventricular function and dysfunction. We also review the unresolved mesostructural questions and challenges that may direct future work in the field.


Subject(s)
Diffusion Tensor Imaging , Myocardium , Animals , Diffusion Magnetic Resonance Imaging/methods , Diffusion Tensor Imaging/methods , Heart Ventricles , Myocardial Contraction , Myocardium/pathology , Myocytes, Cardiac
6.
PLoS Biol ; 17(12): e3000486, 2019 12.
Article in English | MEDLINE | ID: mdl-31856185

ABSTRACT

The conduit network is a hallmark of lymph node microanatomy, but lack of suitable imaging technology has prevented comprehensive investigation of its topology. We employed an extended-volume imaging system to capture the conduit network of an entire murine lymph node (comprising over 280,000 segments). The extensive 3D images provide a comprehensive overview of the regions supplied by conduits, including perivascular sleeves and distinctive "follicular reservoirs" within B cell follicles, surrounding follicular dendritic cells. A 3D topology map of conduits within the T-cell zone showed homogeneous branching, but conduit density was significantly higher in the superficial T-cell zone compared with the deep zone, where distances between segments are sufficient for T cells to lose contact with fibroblastic reticular cells. This topological mapping of the conduit anatomy can now aid modeling of its roles in lymph node function, as we demonstrate by simulating T-cell motility in the different T-cell zones.


Subject(s)
Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Lymph Nodes/diagnostic imaging , Animals , B-Lymphocytes/immunology , Cell Movement , Fibroblasts , Mice/immunology , T-Lymphocytes/immunology
7.
Am J Physiol Heart Circ Physiol ; 321(2): H412-H421, 2021 08 01.
Article in English | MEDLINE | ID: mdl-34213393

ABSTRACT

Detailed global maps of atrial electrical activity are needed to understand mechanisms of atrial rhythm disturbance in small animal models of heart disease. To date, optical mapping systems have not provided enough spatial resolution across sufficiently extensive regions of intact atrial preparations to achieve this goal. The aim of this study was to develop an integrated platform for quantifying regional electrical properties and analyzing reentrant arrhythmia in a biatrial preparation. Intact atria from 6/7-mo-old female spontaneously hypertensive rats (SHRs; n = 6) were isolated and secured in a constant flow superfusion chamber at 37°C. Optical mapping was performed with the membrane-voltage dye di-4-ANEPPS using LED excitation and a scientific complementary metal-oxide semiconductor (sCMOS) camera. Programmed stimulus trains were applied from right atrial (RA) and left atrial (LA) sites to assess rate-dependent electrical behavior and to induce atrial arrhythmia. Signal-to-noise ratio was improved by sequential processing steps that included spatial smoothing, temporal filtering, and, in stable rhythms, ensemble-averaging. Activation time, repolarization time, and action potential duration (APD) maps were constructed at high spatial resolution for a wide range of coupling intervals. These data were highly consistent within and between experiments. They confirmed preferential atrial conduction pathways and demonstrated distinct medial-to-lateral APD gradients. We also showed that reentrant arrhythmias induced in this preparation were explained by the spatial variation of these electrical properties. Our new methodology provides a robust means of 1) quantifying regional electrical properties in the intact rat atria at higher spatiotemporal resolution than previously reported, and 2) characterizing reentrant arrhythmia and analyzing mechanisms that give rise to it.NEW & NOTEWORTHY Despite wide-ranging optical mapping studies, detailed information on regional atrial electrical properties in small animal models of heart disease and how these contribute to reentrant arrhythmia remains limited. We have developed a novel experimental platform that enables both to be achieved in a geometrically intact isolated rat bi-atrial preparation.


Subject(s)
Arrhythmias, Cardiac/diagnostic imaging , Heart Atria/diagnostic imaging , Voltage-Sensitive Dye Imaging/methods , Animals , Arrhythmias, Cardiac/physiopathology , Heart Atria/physiopathology , Rats , Rats, Inbred SHR
8.
Am J Physiol Heart Circ Physiol ; 318(6): H1387-H1400, 2020 06 01.
Article in English | MEDLINE | ID: mdl-32357112

ABSTRACT

Plasticity is a fundamental property of neurons in both the central and peripheral nervous systems, enabling rapid changes in neural network function. The intracardiac nervous system (ICNS) is an extensive network of neurons clustered into ganglionated plexi (GP) on the surface of the heart. GP neurons are the final site of neuronal control of heart rhythm, and pathophysiological remodeling of the ICNS is proposed to feature in multiple cardiovascular diseases, including heart failure and atrial fibrillation. To examine the potential role of GP neuron plasticity in atrial arrhythmia and hypertension, we developed whole cell patch clamp recording techniques from GP neurons in isolated ICNS preparations from aged control (Wistar-Kyoto) and spontaneously hypertensive rats (SHRs). Anesthetized SHRs showed frequent premature ventricular contractions and episodes of atrial arrhythmia following carbachol injection, and isolated SHR atrial preparations were susceptible to pacing induced atrial arrhythmia. Whole cell recordings revealed elevated spontaneous postsynaptic current frequency in SHR GP neurons, as well as remodeled electrophysiology, with significant decreases in action potential amplitude and half-width. SHRs also showed a parallel increase in the number of cholinergic neurons and adrenergic glomus cells in cardiac ganglia, a higher proportion of synaptic α7-subunit but not ß2-containing nicotinic receptors, and an elevation in the number of synaptic terminals onto GP neurons. Our data show that significant structural and functional plasticity occurs in the intracardiac nervous system and suggest that enhanced excitability through synaptic plasticity, together with remodeling of cardiac neuron electrophysiology, contributes to the substrate for atrial arrhythmia in hypertensive heart disease.NEW & NOTEWORTHY We have developed intracardiac neuron whole cell recording techniques in atrial preparations from control and spontaneous hypertensive rats. This has enabled the identification of significant synaptic plasticity in the intracardiac nervous system, including enhanced postsynaptic current frequency, increased synaptic terminal density, and altered postsynaptic receptors. This increased synaptic drive together with altered cardiac neuron electrophysiology could increase intracardiac nervous system excitability and contribute to the substrate for atrial arrhythmia in hypertensive heart disease.


Subject(s)
Arrhythmias, Cardiac/physiopathology , Autonomic Nervous System/physiopathology , Heart/innervation , Hypertension/physiopathology , Neuronal Plasticity/physiology , Action Potentials , Animals , Heart Atria/physiopathology , Neurons/physiology , Patch-Clamp Techniques , Rats , Rats, Inbred SHR , Rats, Inbred WKY
9.
Biophys J ; 117(12): 2273-2286, 2019 12 17.
Article in English | MEDLINE | ID: mdl-31653449

ABSTRACT

Heart failure (HF) is one of the leading causes of death worldwide. HF is associated with substantial microstructural remodeling, which is linked to changes in left ventricular geometry and impaired cardiac function. The role of myocardial remodeling in altering the mechanics of failing hearts remains unclear. Structurally based constitutive modeling provides an approach to improve understanding of the relationship between biomechanical function and tissue organization in cardiac muscle during HF. In this study, we used cardiac magnetic resonance imaging and extended-volume confocal microscopy to quantify the remodeling of left ventricular geometry and myocardial microstructure of healthy and spontaneously hypertensive rat hearts at the ages of 12 and 24 months. Passive cardiac mechanical function was characterized using left ventricular pressure-volume compliance measurements. We have developed a, to our knowledge, new structurally based biomechanical constitutive equation built on parameters quantified directly from collagen distributions observed in confocal images of the myocardium. Three-dimensional left ventricular finite element models were constructed from subject-specific in vivo magnetic resonance imaging data. The structurally based constitutive equation was integrated into geometrically subject-specific finite element models of the hearts and used to investigate the underlying mechanisms of ventricular dysfunction during HF. Using a single pair of material parameters for all hearts, we were able to produce compliance curves that reproduced all of the experimental compliance measurements. The value of this study is not limited to reproducing the mechanical behavior of healthy and diseased hearts, but it also provides important insights into the structure-function relationship of diseased myocardium that will help pave the way toward more effective treatments for HF.


Subject(s)
Heart Failure/pathology , Models, Cardiovascular , Animals , Disease Progression , Heart Failure/complications , Heart Failure/physiopathology , Myocardium/pathology , Pressure , Rats , Ventricular Dysfunction, Left/complications
10.
Microcirculation ; 26(5): e12542, 2019 07.
Article in English | MEDLINE | ID: mdl-30834638

ABSTRACT

Building anatomically accurate models of the coronary vascular system enables potentially deeper understandings of coronary circulation. To achieve this, (a) images at different levels of vascular network-arteries, arterioles, capillaries, venules, and veins-need to be obtained through suitable imaging modalities; and (b) from images, morphological and topological information needs to be extracted using image processing techniques. While there are several modalities that enable the imaging of large vessels, microcirculation imaging-capturing vessels having diameter lesser than 100 µm-has to date been typically confined to small regions of the heart. This spatially limited microcirculatory information has often been used within cardiac models, with the potentially erroneous assumption that it is representative of the whole organ. However, with the recent advancements in imaging and image processing, it is rapidly becoming feasible to acquire, process, and quantify microcirculation data at the scale of whole organ. In this review, we summarize the progress toward this goal followed through a presentation of the current state-of-the-art imaging and image processing techniques in the context of coronary microcirculation extraction, prominently but not exclusively, from small animals.


Subject(s)
Coronary Angiography , Coronary Circulation , Coronary Vessels/diagnostic imaging , Image Processing, Computer-Assisted , Microcirculation , Models, Cardiovascular , Animals , Humans
11.
J Cardiovasc Magn Reson ; 17: 31, 2015 Apr 29.
Article in English | MEDLINE | ID: mdl-25926126

ABSTRACT

BACKGROUND: Cardiovascular magnetic resonance (CMR) can through the two methods 3D FLASH and diffusion tensor imaging (DTI) give complementary information on the local orientations of cardiomyocytes and their laminar arrays. METHODS: Eight explanted rat hearts were perfused with Gd-DTPA contrast agent and fixative and imaged in a 9.4T magnet by two types of acquisition: 3D fast low angle shot (FLASH) imaging, voxels 50 × 50 × 50 µm, and 3D spin echo DTI with monopolar diffusion gradients of 3.6 ms duration at 11.5 ms separation, voxels 200 × 200 × 200 µm. The sensitivity of each approach to imaging parameters was explored. RESULTS: The FLASH data showed laminar alignments of voxels with high signal, in keeping with the presumed predominance of contrast in the interstices between sheetlets. It was analysed, using structure-tensor (ST) analysis, to determine the most (v1(ST)), intermediate (v2(ST)) and least (v3(ST)) extended orthogonal directions of signal continuity. The DTI data was analysed to determine the most (e1(DTI)), intermediate (e2(DTI)) and least (e3(DTI)) orthogonal eigenvectors of extent of diffusion. The correspondence between the FLASH and DTI methods was measured and appraised. The most extended direction of FLASH signal (v1(ST)) agreed well with that of diffusion (e1(DTI)) throughout the left ventricle (representative discrepancy in the septum of 13.3 ± 6.7°: median ± absolute deviation) and both were in keeping with the expected local orientations of the long-axis of cardiomyocytes. However, the orientation of the least directions of FLASH signal continuity (v3(ST)) and diffusion (e3(ST)) showed greater discrepancies of up to 27.9 ± 17.4°. Both FLASH (v3(ST)) and DTI (e3(DTI)) where compared to directly measured laminar arrays in the FLASH images. For FLASH the discrepancy between the structure-tensor calculated v3(ST) and the directly measured FLASH laminar array normal was of 9 ± 7° for the lateral wall and 7 ± 9° for the septum (median ± inter quartile range), and for DTI the discrepancy between the calculated v3(DTI) and the directly measured FLASH laminar array normal was 22 ± 14° and 61 ± 53.4°. DTI was relatively insensitive to the number of diffusion directions and to time up to 72 hours post fixation, but was moderately affected by b-value (which was scaled by modifying diffusion gradient pulse strength with fixed gradient pulse separation). Optimal DTI parameters were b = 1000 mm/s(2) and 12 diffusion directions. FLASH acquisitions were relatively insensitive to the image processing parameters explored. CONCLUSIONS: We show that ST analysis of FLASH is a useful and accurate tool in the measurement of cardiac microstructure. While both FLASH and the DTI approaches appear promising for mapping of the alignments of myocytes throughout myocardium, marked discrepancies between the cross myocyte anisotropies deduced from each method call for consideration of their respective limitations.


Subject(s)
Contrast Media/administration & dosage , Diffusion Tensor Imaging/methods , Gadolinium DTPA/administration & dosage , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Myocytes, Cardiac/cytology , Animals , Isolated Heart Preparation , Male , Myocardial Contraction , Predictive Value of Tests , Rats, Wistar , Ventricular Function, Left
12.
Circ Res ; 111(3): 301-11, 2012 Jul 20.
Article in English | MEDLINE | ID: mdl-22715470

ABSTRACT

RATIONALE: Slow nonuniform electric propagation in the border zone (BZ) of a healed myocardial infarct (MI) can give rise to reentrant arrhythmia. The extent to which this is influenced by structural rather than cellular electric remodeling is unclear. OBJECTIVE: To determine whether structural remodeling alone in the infarct BZ could provide a substrate for re-entry by (i) characterizing the 3-dimensional (3D) structure of the myocardium surrounding a healed MI at high spatial resolution and (ii) modeling electric activation on this structure. METHODS AND RESULTS: Anterior left ventricular (LV) infarcts were induced in 2 rats by coronary artery ligation. Three-dimensional BZ volume (4.1 mm(3) and 5.6 mm(3)) were imaged at 14 days using confocal microscopy. Viable myocytes were identified, and their connectivity and orientation were quantified. Preserved cell networks were observed in the subendocardium and subepicardium of the infarct. Myocyte tracts traversed the BZ, and there was heavy infiltration of collagen into the adjacent myocardium. Myocyte connectivity decreased by ≈65% over 250 µm across the BZ. This structure was incorporated into 3D network models on which activation was simulated using Luo-Rudy membrane dynamics assuming normal cellular electric properties. Repetitive stimulation was imposed at selected BZ sites. Stimulus site-specific unidirectional propagation occurred in the BZ with rate-dependent slowing and conduction block, and reentry was demonstrated in one substrate. Activation times were prolonged because of tract path length and local slowing. CONCLUSIONS: We have used a detailed image-based model of the infarct BZ to demonstrate that structural heterogeneity provides a dynamic substrate for electric reentry.


Subject(s)
Heart Conduction System/physiology , Heart Conduction System/physiopathology , Imaging, Three-Dimensional , Myocardial Infarction/etiology , Myocardial Infarction/pathology , Ventricular Remodeling/physiology , Animals , Imaging, Three-Dimensional/methods , Male , Myocardial Infarction/physiopathology , Myocytes, Cardiac/pathology , Myocytes, Cardiac/physiology , Rats
13.
Article in English | MEDLINE | ID: mdl-38082870

ABSTRACT

Swallowing involves the precise coordination of a large number of muscles. This coordination can be quantified non-invasively by electromyographic (EMG) time-series analysis of swallowing events. The temporal alignment of swallow events is critical for defining coordination patterns. Here, a new framework was developed to use the acoustic signal associated with the opening of the Eustachian tube as a fiducial marker to align EMG signals with swallowing. To investigate its accuracy, manometry, audio from the Eustachian tube, and EMG were simultaneously recorded from two participants while performing different swallowing maneuvers. Eustachian tube opening consistently occurred alongside EMG activations and within 0.025 ± 0.022 s of the gold standard manometry-determined functional swallowing onset. A comparison with two traditional EMG alignment methods based on the integrated and rectified EMG signals was then performed over eight participants. Discrepancies of between 0.2 to 0.3 s were found between the initiation of swallowing and the onset or peak EMG activity. Eustachian tube opening served as a more accurate fiducial marker for temporal data alignment, compared to the traditional EMG alignment methods that were based on EMG parameters.Clinical Relevance- The proposed method will allow EMG recordings to be directly associated with the functional onset of swallowing. This provides a more accurate foundation for time-series analysis of muscle coordination and thus the identification of EMG biomarkers associated with healthy and dysphagic swallowing.


Subject(s)
Fiducial Markers , Muscles , Humans , Electromyography/methods , Muscles/physiology , Manometry/methods
14.
J Hypertens ; 41(10): 1606-1614, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37466436

ABSTRACT

BACKGROUND: Left ventricular (LV) global longitudinal strain (GLS) has been proposed as an early imaging biomarker of cardiac mechanical dysfunction. OBJECTIVE: To assess the impact of angiotensin-converting enzyme (ACE) inhibitor treatment of hypertensive heart disease on LV GLS and mechanical function. METHODS: The spontaneously hypertensive rat (SHR) model of hypertensive heart disease ( n  = 38) was studied. A subset of SHRs received quinapril (TSHR, n  = 16) from 3 months (mo). Wistar Kyoto rats (WKY, n  = 13) were used as controls. Tagged cardiac MRI was performed using a 4.7 T Varian preclinical scanner. RESULTS: The SHRs had significantly lower LV ejection fraction (EF) than the WKYs at 3 mo (53.0 ±â€Š1.7% vs. 69.6 ±â€Š2.1%, P  < 0.05), 14 mo (57.0 ±â€Š2.5% vs. 74.4 ±â€Š2.9%, P  < 0.05) and 24 mo (50.1 ±â€Š2.4% vs. 67.0 ±â€Š2.0%, P  < 0.01). At 24 mo, ACE inhibitor treatment was associated with significantly greater LV EF in TSHRs compared to untreated SHRs (64.2 ±â€Š3.4% vs. 50.1 ±â€Š2.4%, P  < 0.01). Peak GLS magnitude was significantly lower in SHRs compared with WKYs at 14 months (7.5% ±â€Š0.4% vs. 9.9 ±â€Š0.8%, P  < 0.05). At 24 months, Peak GLS magnitude was significantly lower in SHRs compared with both WKYs (6.5 ±â€Š0.4% vs. 9.7 ±â€Š1.0%, P  < 0.01) and TSHRs (6.5 ±â€Š0.4% vs. 9.6 ±â€Š0.6%, P  < 0.05). CONCLUSIONS: ACE inhibitor treatment curtails the decline in global longitudinal strain in hypertensive rats, with the treatment group exhibiting significantly greater LV EF and GLS magnitude at 24 mo compared with untreated SHRs.


Subject(s)
Heart Diseases , Hypertension , Rats , Animals , Quinapril , Rats, Inbred WKY , Global Longitudinal Strain , Hypertension/drug therapy , Angiotensin-Converting Enzyme Inhibitors/pharmacology , Angiotensin-Converting Enzyme Inhibitors/therapeutic use , Rats, Inbred SHR , Blood Pressure
15.
Article in English | MEDLINE | ID: mdl-38083720

ABSTRACT

The right-ventricular (RV) outflow tract (RVOT) and the transition to the RV free wall are recognized sources of arrhythmia in human hearts. However, we do not fully understand myocardial tissue structures in this region. Human heart tissue was processed for optical clarity, labelled with wheat-germ agglutin (WGA) and anti-Cx43, and imaged on a custom-built line scanning confocal microscope. The 3D images were analyzed for myocyte gross structures and cell morphology. There were regions of high organization as well as rapid changes to more heterogeneous regions. Preliminary cell segmentations were used to estimate cell morphology. Observed RVOT/RV structure is consistent with known arrhythmic substrates.Clinical Relevance- New views of human tissue structure enable clearer clinical understanding of arrhythmogenic activation pathways and targets for invasive treatment such as RF ablation.


Subject(s)
Heart Ventricles , Heart , Humans , Myocardium , Arrhythmias, Cardiac , Imaging, Three-Dimensional
16.
Sci Rep ; 13(1): 11824, 2023 07 21.
Article in English | MEDLINE | ID: mdl-37479717

ABSTRACT

Gastric motility is coordinated by bioelectrical slow-wave activity, and abnormal electrical dysrhythmias have been associated with nausea and vomiting. Studies have often been conducted under general anaesthesia, while the impact of general anaesthesia on slow-wave activity has not been studied. Clinical studies have shown that propofol anaesthesia reduces postoperative nausea and vomiting (PONV) compared with isoflurane, while the underlying mechanisms remain unclear. In this study, we investigated the effects of two anaesthetic drugs, intravenous (IV) propofol and volatile isoflurane, on slow-wave activity. In vivo experiments were performed in female weaner pigs (n = 24). Zolazepam and tiletamine were used to induce general anaesthesia, which was maintained using either IV propofol (n = 12) or isoflurane (n = 12). High-resolution electrical mapping of slow-wave activity was performed. Slow-wave dysrhythmias occurred less often in the propofol group, both in the duration of the recorded period that was dysrhythmic (propofol 14 ± 26%, isoflurane 43 ± 39%, P = 0.043 (Mann-Whitney U test)), and in a case-by-case basis (propofol 3/12, isoflurane 8/12, P = 0.015 (Chi-squared test)). Slow-wave amplitude was similar, while velocity and frequency were higher in the propofol group than the isoflurane group (P < 0.001 (Student's t-test)). This study presents a potential physiological biomarker linked to recent observations of reduced PONV with IV propofol. The results suggest that propofol is a more suitable anaesthetic for studying slow-wave patterns in vivo.


Subject(s)
Anesthetics, Inhalation , Isoflurane , Propofol , Female , Animals , Swine , Propofol/pharmacology , Isoflurane/adverse effects , Postoperative Nausea and Vomiting , Incidence , Anesthetics, Intravenous/pharmacology , Anesthetics, Inhalation/pharmacology , Anesthesia, General/adverse effects
17.
Am J Physiol Heart Circ Physiol ; 303(11): H1353-65, 2012 Dec 01.
Article in English | MEDLINE | ID: mdl-23001837

ABSTRACT

The progression of hypertensive heart disease (HHD) to heart failure (HF) is associated with myocardial remodeling. Corresponding changes in three-dimensional organization of cardiac extracellular matrix have not been quantified or related fully to the development of HF. Spontaneously hypertensive rats (SHRs) and Wistar-Kyoto controls were studied at 3, 12, 18, and 24 mo. Hemodynamic and morphological data, brain natriuretic peptide levels, and echocardiography demonstrate four distinct disease stages: systemic hypertension, diastolic dysfunction, early systolic failure, and decompensated HF. Passive left ventricular (LV) pressure-volume relationships were determined in vitro. Transmural specimens from the anterior LV free wall were imaged using extended-volume confocal microscopy, and three-dimensional myocardial architecture was quantified. In SHRs, LV compliance was reduced at 12 mo and increased progressively thereafter. However, it was less than in controls for filling pressures <10 mmHg and not significantly different at ≥10 mmHg. Myocyte cross section was enlarged, with increased variability from 12 mo, while collagen fraction increased progressively. Perimysial collagen fraction remained unchanged with age, although endomysial collagen increased from 12 mo. Perimysial collagen between adjacent muscle layers fused at 12 mo and continued to thicken subsequently, while muscle layers became more dispersed and disordered. We conclude that LV dilatation, which accompanies decompensated HF in this model of HHD, is not due to LV "softening." While perimysial (and endomysial) collagen networks are substantially remodeled, they are not dissolved, as has been proposed. We argue that progressive disruption of the laminar organization of LV myocardium may contribute to impaired systolic function in HHD.


Subject(s)
Disease Progression , Heart Failure/physiopathology , Hypertension/physiopathology , Ventricular Dysfunction, Left/physiopathology , Ventricular Remodeling/physiology , Animals , Collagen/metabolism , Disease Models, Animal , Echocardiography , Heart Failure/metabolism , Heart Ventricles/diagnostic imaging , Heart Ventricles/metabolism , Heart Ventricles/pathology , Hypertension/metabolism , Natriuretic Peptide, Brain/metabolism , Rats , Rats, Inbred SHR , Rats, Inbred WKY , Time Factors , Ventricular Dysfunction, Left/metabolism
18.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 5004-5007, 2022 07.
Article in English | MEDLINE | ID: mdl-36086539

ABSTRACT

Gastric ablation has recently emerged as a promising potential therapy for correcting bioelectrical dysrhythmias that underpin many gastrointestinal motility disorders. Despite similarities to well-developed cardiac radiofrequency (RF) ablation, gastric RF ablation is in its infancy and has thus far been limited to temperature-controlled, non-irrigated settings. The potential benefits of power-controlled and irrigated RF ablation have not been investigated in gastric tissue. In this study, RF ablation was performed in vivo in pigs ( n=5) using a range of power-control (10-30 W, 10s per point) and irrigation (2-5 ml/min) settings and compared to known temperature-controlled (65°C), non-irrigated settings. Excised tissue was stained with H&E. Lesion surface area was calculated and tissue damage was quantitatively ranked by visual assessment. The results demonstrated that irrigation allowed greater energy delivery to tissue with reduced interface temperatures compared to non-irrigated settings. Power settings above 10 W created lesions that extended through the full-thickness of the muscle layer, which suggests the parameter range that can now be used to correct gastric dysrhythmias. Clinical Relevance- This work presents the results of power-controlled, irrigated RF ablation settings applied to the in vivo porcine stomach. The relationships of both lesion area and depth to ablation dose provides an improved insight into which energy doses could provide a safe and effective therapeutic response.


Subject(s)
Catheter Ablation , Therapeutic Irrigation , Animals , Catheter Ablation/methods , Heart Ventricles/surgery , Swine , Temperature
19.
Front Physiol ; 13: 873049, 2022.
Article in English | MEDLINE | ID: mdl-35651876

ABSTRACT

Introduction: Atrial fibrillation (AF) is the most prevalent cardiac dysrhythmia and percutaneous catheter ablation is widely used to treat it. Panoramic mapping with multi-electrode catheters can identify ablation targets in persistent AF, but is limited by poor contact and inadequate coverage. Objective: To investigate the accuracy of inverse mapping of endocardial surface potentials from electrograms sampled with noncontact basket catheters. Methods: Our group has developed a computationally efficient inverse 3D mapping technique using a meshless method that employs the Method of Fundamental Solutions (MFS). An in-silico test bed was used to compare ground-truth surface potentials with corresponding inverse maps reconstructed from noncontact potentials sampled with virtual catheters. Ground-truth surface potentials were derived from high-density clinical contact mapping data and computer models. Results: Solutions of the intracardiac potential inverse problem with the MFS are robust, fast and accurate. Endocardial surface potentials can be faithfully reconstructed from noncontact recordings in real-time if the geometry of cardiac surface and the location of electrodes relative to it are known. Larger catheters with appropriate electrode density are needed to resolve complex reentrant atrial rhythms. Conclusion: Real-time panoramic potential mapping is feasible with noncontact intracardiac catheters using the MFS. Significance: Accurate endocardial potential maps can be reconstructed in AF with appropriately designed noncontact multi-electrode catheters.

20.
Front Physiol ; 13: 873630, 2022.
Article in English | MEDLINE | ID: mdl-35874529

ABSTRACT

Atrial fibrillation (AF) is the most common cardiac dysrhythmia and percutaneous catheter ablation is widely used to treat it. Panoramic mapping with multi-electrode catheters has been used to identify ablation targets in persistent AF but is limited by poor contact and inadequate coverage of the left atrial cavity. In this paper, we investigate the accuracy with which atrial endocardial surface potentials can be reconstructed from electrograms recorded with non-contact catheters. An in-silico approach was employed in which "ground-truth" surface potentials from experimental contact mapping studies and computer models were compared with inverse potential maps constructed by sampling the corresponding intracardiac field using virtual basket catheters. We demonstrate that it is possible to 1) specify the mixed boundary conditions required for mesh-based formulations of the potential inverse problem fully, and 2) reconstruct accurate inverse potential maps from recordings made with appropriately designed catheters. Accuracy improved when catheter dimensions were increased but was relatively stable when the catheter occupied >30% of atrial cavity volume. Independent of this, the capacity of non-contact catheters to resolve the complex atrial potential fields seen in reentrant atrial arrhythmia depended on the spatial distribution of electrodes on the surface bounding the catheter. Finally, we have shown that reliable inverse potential mapping is possible in near real-time with meshless methods that use the Method of Fundamental Solutions.