Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Environ Monit Assess ; 193(7): 434, 2021 Jun 21.
Article in English | MEDLINE | ID: mdl-34152497

ABSTRACT

The concentrations and temporal variations of polychlorodibenzo-p-dioxins and polychlorodibenzofurans (PCDDs/PCDFs) in ambient air between March 2013 and February 2017 were investigated by passive air samplers containing polyurethane foam (PUF) disks in the dioxin remediation area using in-pile thermal desorption (IPTD) technology at Da Nang airport, Vietnam. The PCDD/PCDF concentrations in ambient air at each site depended on the location of the emission sources and the wind direction, the dioxin contamination level of excavated materials, the periods of excavation and transport, and the operation of the IPTD treatment system. The PCDD/PCDF concentrations were the highest in the former Agent Orange mixing and loading area (AOMLA), which was the closest to the IPTD system, with total toxic equivalent (TEQ) values ranging from 0.437 to 15.3 pg/PUF/day. The total TEQ concentrations in the Sen Lake area ranged from 0.138 to 2.41 pg/PUF/day. The lowest concentration of PCDDs/PCDFs occurred in the northern perimeter area, with total TEQ values ranging from 0.164 to 0.972 pg/PUF/day. The decreasing trend of the PCDD/PCDF concentrations in ambient air was confirmed over time at all three monitoring sites, among which there was a strong decrease in the former AOMLA after February 2015. Residents living near the Da Nang airport were at a low risk of being exposed to PCDDs/PCDFs through inhalation during remediation project implementation, while residents living close to the former AOMLA faced elevated risks with an average daily dose of PCDDs/PCDFs through inhalation ranging from 0.017 to 0.82 pg TEQ/kg body weight/day.


Subject(s)
Dioxins , Polychlorinated Biphenyls , Polychlorinated Dibenzodioxins , Dibenzofurans, Polychlorinated , Dioxins/analysis , Environmental Monitoring , Polychlorinated Dibenzodioxins/analysis , Vietnam
2.
Environ Sci Pollut Res Int ; 31(44): 56130-56139, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39256336

ABSTRACT

The air pollution levels from polychlorodibenzo-p-dioxins/polychlorodibenzofurans (PCDD/Fs) and dioxin-like polychlorobiphenyls (dl-PCBs) in three residential areas located north, west, and south of the Da Nang airport were determined by using passive air samplers containing polyurethane foam (PUF) discs with 3-month sampling intervals from 2017 to 2020. The total toxic equivalents (∑TEQs) of the PCDD/Fs and dl-PCBs, using WHO2005-TEFs, were highest north of the airport (134 to 10610 fg WHO-TEQ/PUF day, with an average of 1108 fg WHO-TEQ/PUF day). The ∑TEQs were lower west of the airport, between 159 and 381 fg WHO-TEQ/PUF day and averaged 230 fg WHO-TEQ/PUF day. The lowest ∑TEQs occurred south of the airport, with ranges of 76 and 331 fg WHO-TEQ/PUF day and an average of 152 fg WHO-TEQ/PUF day. Construction activities, including excavation and transportation of dioxin-contaminated soil north of the airport, have increased airborne PCDD/F and dl-PCB contamination and health risks. The average daily doses of PCDD/Fs and dl-PCBs through inhalation (ADDA) for residents located north of the airport were the highest (10.9 to 3434 fg WHO-TEQ/kg BW/day and average: 597 fg WHO-TEQ/kg BW/day). Residents located west of the airport faced lower health risks (13-123 fg WHO-TEQ/kg BW/day and average: 39 fg WHO-TEQ/kg BW/day). Residents south of the airport were exposed to a minimum of 6.2-107 fg WHO-TEQ/kg BW/day, with an average of 28 fg WHO-TEQ/kg BW/day. The maximum and average ADDA values for residents north of the airport exceeded 10% of the tolerable daily intake (TDI) recommended by the WHO (100-400 fg WHO-TEQ/kg BW/day). In comparison, all the ADDA values for residents located west and south of the airport were less than and within 10% of the TDI.


Subject(s)
Air Pollutants , Polychlorinated Biphenyls , Polychlorinated Dibenzodioxins , Polychlorinated Dibenzodioxins/analysis , Risk Assessment , Vietnam , Air Pollutants/analysis , Humans , Polychlorinated Biphenyls/analysis , Environmental Monitoring , Air Pollution , Benzofurans/analysis , Dioxins/analysis
3.
Chemosphere ; 364: 143238, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39222695

ABSTRACT

Passive air samplers were used to monitor polychlorodibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorobiphenyls (dl-PCBs) between 2020 and 2022 in four residential areas around Bien Hoa hot spot (BHS) including Trung Dung (TD), Tan Phong (TP), Quang Vinh (QV), and Buu Long (BL). The total toxic equivalents of PCDD/Fs and dl-PCBs (∑TEQs) were highest in the TD area, from 284 to 642 fg TEQ/PUF day. Next was the QV area, where ∑TEQs ranged from 229 to 569 fg TEQ/PUF day. Then, ∑TEQs varied from 205 to 503 fg TEQ/PUF day in the TP area. The lowest ∑TEQs were between 179 and 385 fg TEQ/PUF day in the BL area. The temporal, spatial, and seasonal variations in concentrations of PCDD/Fs and dl-PCBs were related to the prevailing wind direction and the distance from each area to the dioxin hot spot. The average ∑TEQs for all four areas surrounding BHS in the dry season (423 fg TEQ/PUF day) were 1.4 times higher than in the rainy season (303 fg TEQ/PUF day). Health risk assessments from airborne dioxin exposure were estimated using the average daily doses through inhalation (ADDI). The ADDI for residents surrounding BHS ranged from 14.6 to 208 fg TEQ/kg BW/day. The ADDI values by areas were as follows: 23.2-208 fg TEQ/kg BW/day in the TD, 18.7-184 fg TEQ/kg BW/day in the QV, 16.7-163 fg TEQ/kg BW/day in the TP, and 14.6-125 fg TEQ/kg BW/day in the BL. These ADDI values remained within and below the 10% threshold of the WHO-recommended tolerable daily intake (100-400 fg TEQ/kg BW/day). It is necessary to control the excavation activities inside the BHS and cover the temporary storage sites of dioxin-contaminated materials to minimize the emissions of PCDD/Fs and dl-PCB into the ambient air.


Subject(s)
Air Pollutants , Air Pollution , Dibenzofurans , Polychlorinated Dibenzodioxins , Polychlorinated Dibenzodioxins/analysis , Dibenzofurans/analysis , Vietnam , Seasons , Air Pollution/statistics & numerical data , Environmental Monitoring , Risk Assessment , Environmental Exposure/statistics & numerical data
4.
Environ Sci Pollut Res Int ; 30(43): 98440-98451, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37606774

ABSTRACT

The concentrations and seasonal and temporal variations in polychlorodibenzo-p-dioxins/polychlorodibenzofurans (PCDD/Fs) and dioxin-like polychlorobiphenyls (dl-PCBs) in ambient air from November 2017 to September 2021 were investigated via passive air samplers containing polyurethane foam (PUF) discs in three residential areas: the Cau Giay (CG) urban, Quang Minh (QM) industrial-suburban, and Ba Vi (BV) rural areas, Hanoi, Vietnam. The average total toxic equivalents (TEQs) of PCDD/Fs and dl-PCBs (∑TEQs), using WHO2005-TEFs, were highest in the QM area (506 fg WHO-TEQ/PUF day) and ranged from 317 to 752 fg WHO-TEQ/PUF day. Compared to that in the QM area, the average ∑TEQs were lower in the CG area, ranging between 372 and 615 fg WHO-TEQ/PUF day with an average value of 482 fg WHO-TEQ/PUF day. The average ∑TEQs were lowest in the BV area, ranging from 121 to 414 fg WHO-TEQ/PUF day with an average of 231 fg WHO-TEQ/PUF day. PCDD/F and dl-PCB air pollution increased during spring and winter. The highest seasonal average ∑TEQs in the CG area was 534 fg WHO-TEQ/PUF day in winter. The highest average ∑TEQs in the QM and BV areas were 653 and 280 fg WHO-TEQ/PUF day in spring, respectively. The average daily dose (ADD) values of PCDD/Fs and dl-PCBs through inhalation for adults in the three areas were minimal (9.9-96.2 fg WHO-TEQ/kg body weight (BW)/day) and below the 10% threshold of the tolerable daily intake (TDI) value recommended by the WHO (100-400 fg WHO-TEQ/kg BW/day). For children, the ADD values (15.1-244 fg WHO-TEQ/kg BW/day) were less than and within 10% of the recommended TDI value.


Subject(s)
Dioxins , Polychlorinated Biphenyls , Polychlorinated Dibenzodioxins , Adult , Child , Humans , Dibenzofurans , Vietnam , Risk Assessment , Body Weight
5.
Pathogens ; 10(4)2021 Mar 25.
Article in English | MEDLINE | ID: mdl-33806156

ABSTRACT

To cause a pandemic, an influenza virus has to overcome two main barriers. First, the virus has to be antigenically new to humans. Second, the virus has to be directly transmitted from humans to humans. Thus, if the avian influenza virus is able to pass the second barrier, it could cause a pandemic, since there is no immunity to avian influenza in the human population. To determine whether the adaptation process is ongoing, analyses of human sera could be conducted in populations inhabiting regions where pandemic virus variant emergence is highly possible. This study aimed to analyze the sera of Vietnamese residents using hemagglutinin inhibition reaction (HI) and microneutralization (MN) with A/H5Nx (clade 2.3.4.4) influenza viruses isolated in Vietnam and the Russian Federation in 2017-2018. In this study, we used sera from 295 residents of the Socialist Republic of Vietnam collected from three groups: 52 samples were collected from households in Nam Dinh province, where poultry deaths have been reported (2017); 96 (2017) and 147 (2018) samples were collected from patients with somatic but not infectious diseases in Hanoi. In all, 65 serum samples were positive for HI, at least to one H5 virus used in the study. In MN, 47 serum samples neutralizing one or two viruses at dilutions of 1/40 or higher were identified. We postulate that the rapidly evolving A/H5Nx (clade 2.3.4.4) influenza virus is possibly gradually adapting to the human host, insofar as healthy individuals have antibodies to a wide spectrum of variants of that subtype.

SELECTION OF CITATIONS
SEARCH DETAIL