Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 201
Filter
Add more filters

Publication year range
1.
Article in English | MEDLINE | ID: mdl-38490356

ABSTRACT

OBJECTIVE: The midterm outcomes of the low profile Zenith Alpha Abdominal Endovascular Graft from the ZEnith alPHa for aneurYsm Repair (ZEPHYR) registry are reported. METHODS: The ZEPHYR registry is a physician initiated, multicentre, non-randomised, core laboratory controlled, prospective registry. Inclusion criteria were patients with a non-ruptured abdominal aortic aneurysm with a maximum diameter ≥ 50 mm or enlargement > 5 mm within 6 months, with a site reported infrarenal neck length of ≥ 10 mm and with the intention to electively implant the Zenith Alpha abdominal endograft. Patients from 14 sites across Germany, Belgium, and the Netherlands were included. The primary endpoint was treatment success, defined as technical success and clinical success. Technical success was defined as successful delivery and deployment of the endograft in the planned position without unintentional coverage of internal iliac or renal arteries, with successful removal of the delivery system. Clinical success was defined as freedom from aneurysm sac expansion > 5 mm, type I or type III endoleaks, aneurysm rupture, stent graft migration > 10 mm, open conversion, and stent graft occlusion. RESULTS: Three hundred and forty-seven patients were included in the ZEPHYR registry. The median clinical follow up was 743 days (interquartile range [IQR] 657, 806) with a median imaging follow up of 725 days (IQR 408, 788). Treatment success at 6 months, 1, and 2 years was 92.5%, 90.4%, and 85.3%, respectively. Freedom from secondary intervention was 94.3%, 93.4%, and 86.9%, respectively. The predominant reason for secondary intervention was limb complications. Freedom from limb occlusion (per patient) at 6 months, 1, and 2 years was 97.2%, 95.8%, and 92.5%, respectively. Univariable and multivariable Cox regression analyses could not identify any independent predictor for limb complications. CONCLUSION: While treatment success is comparable with other commercially available grafts, the rate of limb complications at 2 years is of concern. The manufacturer's instructions for use should be followed closely. Further studies are necessary to investigate the root cause of the increased rate of limb complications with the Zenith Alpha Abdominal Endovascular Graft.

2.
J Endovasc Ther ; : 15266028231169178, 2023 May 08.
Article in English | MEDLINE | ID: mdl-37154344

ABSTRACT

PURPOSE: Endovascular aortic repair (EVAR) is the method of choice for most abdominal aortic aneurysm (AAA) patients requiring intervention. However, chronic aortic neck dilatation (AND) following EVAR progressively weakens the structural seal between vessel and endograft and compromises long-term results of the therapy. This experimental ex vivo study seeks to investigate mechanisms of AND. MATERIALS AND METHODS: Porcine abdominal aortas (n=20) were harvested from slaughterhouse pigs and connected to a mock circulation. A commercially available endograft was implanted (n=10) or aortas were left untreated as controls (n=10). Vascular circumferential strain was assessed via ultrasound in defined aortic segments as a parameter of aortic stiffness. Histology and aortic gene expression analysis were performed to investigate potential changes of aortic wall structure and molecular differences due to endograft implantation. RESULTS: We found that endograft implantation acutely induces a significant stiffness gradient directly at the interface between stented and unstented aortic segments under pulsatile pressure. Comparing stented aortas with unstented controls, we detected increased aortic expression levels of inflammatory cytokines (Il6 and Ccl2) and matrix metalloproteinases (Mmp2 and Mmp9) after 6 hours of pulsatile pressurization. This effect, however, was abolished when repeating the same experiment under 6 hours of static pressure. CONCLUSIONS: We identified endograft-induced aortic stiffness gradients as an early trigger of inflammatory aortic remodeling processes that might promote AND. These results highlight the importance of adequate endograft designs to minimize vascular stiffness gradients and forestall late complications, such as AND. CLINICAL IMPACT: AND may compromise the long-term results following endovascular aortic repair. However, the mechanisms behind the underlying detrimental aortic remodeling are still unclear. In this study we find that endograft-induced aortic stiffness gradients induce an inflammatory aortic remodeling response consistent with AND. This novel pathomechanistic insight may guide the design of new aortic endografts that minimize vascular stiffness gradients and forestall late complications such as AND.

3.
Int J Mol Sci ; 24(4)2023 Feb 16.
Article in English | MEDLINE | ID: mdl-36835370

ABSTRACT

Clonal hematopoiesis (CH)-associated mutations increase the risk of atherosclerotic cardiovascular diseases. However, it is unclear whether the mutations detected in circulating blood cells can also be detected in tissues associated with atherosclerosis, where they could affect physiology locally. To address this, the presence of CH mutations in peripheral blood, atherosclerotic lesions and associated tissues was assessed in a pilot study of 31 consecutive patients with peripheral vascular disease (PAD) who underwent open surgical procedures. Next-generation sequencing was used to screen the most commonly mutated loci (DNMT3A, TET2, ASXL1 and JAK2). Twenty CH mutations were detected in peripheral blood of 14 (45%) patients, 5 of whom had more than one mutation. TET2 (11 mutations, 55%) and DNMT3A (8 mutations, 40%) were the most frequently affected genes. Altogether, 88% of the mutations detectable in peripheral blood were also present in the atherosclerotic lesions. Twelve patients also had mutations in perivascular fat or subcutaneous tissue. The presence of CH mutations in PAD-associated tissues as well as in blood suggests that CH mutations may make a previously unknown contribution to PAD disease biology.


Subject(s)
Clonal Hematopoiesis , Peripheral Arterial Disease , Humans , Clonal Hematopoiesis/genetics , Mutation , Peripheral Arterial Disease/genetics , Pilot Projects
4.
Catheter Cardiovasc Interv ; 100(6): 1090-1099, 2022 11.
Article in English | MEDLINE | ID: mdl-36229946

ABSTRACT

OBJECTIVES: The PERFORMANCE I study was designed to evaluate the safety and feasibility of the Neuroguard IEP® System, a novel carotid stent system with an integrated embolic filter and post-dilatation balloon, to treat clinically significant carotid artery stenosis. BACKGROUND: The risk of major adverse events during carotid artery stenting is comparable to carotid endarterectomy, however, the risk of minor stroke remains higher with stenting. METHODS: In total, 67 patients undergoing carotid artery stenting were enrolled at nine centers in Europe. Follow-up assessments included neurological exams, duplex ultrasound, 12-lead electrocardiogram, and cardiac enzyme analysis. The primary endpoint was the 30-day composite rate of stroke, death, and myocardial infarctions versus a prespecified performance goal. Secondary endpoints included procedure success, device success, and target lesion revascularization. RESULTS: The study population was predominantly male (74.6%) with a mean age of 69.3 ± 8.9 years and 67% of subjects met at least one criterion placing them at an elevated risk for adverse events following carotid endarterectomy. All patients were treated successfully with the study device. There were no deaths or strokes within 30 days of the index procedure. One subject (1.5%) experienced a non-ST elevation myocardial infarction at day 17. The primary endpoint was met with a 30-day major adverse events rate of 1.5% (1/67). Through 12-month follow-up, there were no strokes, neurological deaths, target lesion revascularizations, or instances of in-stent-restenosis. CONCLUSIONS: Results from this study demonstrate the Neuroguard IEP system is safe and feasible with a stroke/death rate of 0% at 30 days. A large pivotal study is currently underway.


Subject(s)
Carotid Stenosis , Embolic Protection Devices , Endarterectomy, Carotid , Stroke , Humans , Male , Middle Aged , Aged , Female , Carotid Stenosis/complications , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/therapy , Stents , Dilatation , Treatment Outcome , Time Factors , Stroke/etiology , Stroke/prevention & control , Risk Factors
5.
J Endovasc Ther ; 29(1): 84-95, 2022 02.
Article in English | MEDLINE | ID: mdl-34465223

ABSTRACT

PURPOSE: This study investigated the 2-year safety and effectiveness of the PQ Bypass DETOUR system as a percutaneous femoropopliteal bypass. MATERIALS AND METHODS: Seventy-eight patients with 82 long-segment femoropopliteal lesions were enrolled in this prospective, single-arm, multicenter study. The DETOUR system deployed Torus stent grafts directed through a transvenous route. Eligible patients included those with lesions of >10 cm and average of 371±55 mm. Key safety endpoints included major adverse events (MAEs) and symptomatic deep venous thrombosis in the target limb. Effectiveness endpoints included primary patency defined as freedom from ≥50% stenosis, occlusion, or clinically-driven target vessel revascularization (CD-TVR), primary assisted, and secondary patency. RESULTS: Chronic total occlusions and severe calcium occurred in 96% and 67% of lesions, respectively. Core laboratory-assessed total lesion length averaged 371±51 mm with a mean occlusion length of 159±88 mm. The rates of technical and procedural success were 96%, with satisfactory delivery and deployment of the device without in-hospital MAEs in 79/82 limbs. The MAE rate was 22.0%, with 3 unrelated deaths (4%), 12 CD-TVRs (16%), and 1 major amputation (1%). Deep venous thrombosis developed in 2.8% of target limbs, and there were no reported pulmonary emboli. Primary, assisted primary, and secondary patency rates by the Kaplan-Meier analysis were 79±5%, 79±5%, and 86±4%, respectively. CONCLUSIONS: The PQ Bypass DETOUR system is a safe and effective percutaneous alternative to femoropopliteal open bypass with favorable results through 2 years. The DETOUR system provides a durable alternative to conventional endovascular modalities and open surgery for patients with long, severely calcified, or occluded femoropopliteal lesions.


Subject(s)
Endovascular Procedures , Peripheral Arterial Disease , Endovascular Procedures/adverse effects , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Humans , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/surgery , Popliteal Artery/diagnostic imaging , Popliteal Artery/surgery , Prospective Studies , Stents , Treatment Outcome , Vascular Patency
6.
J Endovasc Ther ; 29(5): 798-807, 2022 10.
Article in English | MEDLINE | ID: mdl-34964369

ABSTRACT

PURPOSE: To evaluate the use of the GoBack-catheter (Upstream Peripheral Technologies) in complex revascularizations in lower limb arteries. MATERIALS AND METHODS: In this retrospective single-center study, the results of the first 100 consecutive patients including 101 limb-revascularizations, performed between May 2018 and July 2020 with the study device, were analyzed. In all cases, guidewire-crossing failed, and all lesions were chronic total occlusions (CTO), either de novo, reocclusions, or in-stent reocclusions. Successful crossing was defined as passing the CTO using the study device. Patency at discharge and after 30 days was defined as less than 50% restenosis on duplex sonography, without target lesion revascularization. RESULTS: Median lesion length was 24 cm and 38 patients (37.6%) had a calcium grading according to the peripheral arterial calcium scoring system (PACSS) of 4 or 5. In 20.8% of patients, an occluded stent was treated. CTOs involved the femoropopliteal segment in 91.1%, iliac arteries in 5.9%, and tibial arteries in 7.9%. The GoBack-catheter was employed for entering into or crossing through parts or the full length of a CTO or an occluded stent as well as for re-entering into the true lumen after subintimal crossing. The device was used via contralateral and ipsilateral antegrade as well as retrograde access with an overall technical success rate of 92.1%. In 3 patients minor bleeding occurred at the crossing or re-entry site, which were managed conservatively. Thirty-day adverse limb events comprised minor amputations in 4 patients (4.0%), 1 major amputation (1.0%), and reocclusions in 7 limbs (6.9%). CONCLUSION: The new GoBack-catheter offers versatile endovascular applicability for complex CTO recanalization in a broad range of peripheral vascular interventions with a high technical success and low complication rate.


Subject(s)
Arterial Occlusive Diseases , Peripheral Arterial Disease , Arterial Occlusive Diseases/diagnostic imaging , Arterial Occlusive Diseases/therapy , Calcium , Catheters , Chronic Disease , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Humans , Lower Extremity , Peripheral Arterial Disease/complications , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Popliteal Artery/surgery , Retrospective Studies , Treatment Outcome
7.
Eur J Vasc Endovasc Surg ; 64(5): 516-525, 2022 11.
Article in English | MEDLINE | ID: mdl-35973667

ABSTRACT

OBJECTIVE: Data on paclitaxel coated balloons (PCBs) for below knee (BTK) angioplasty exhibited conflicting efficacy results, and previous meta-analyses suggested an increased mortality and amputation risk highlighting the need for further research. The aim of this study was to investigate safety and efficacy of PCBs for BTK interventions in a real world cohort. METHODS: Within a single centre cohort study, 552 consecutive patients were included undergoing BTK interventions with and without PCB use. Two year safety and efficacy results were compared in unadjusted and propensity score matched (PSM) analysis. RESULTS: BTK interventions were performed in 157 patients with PCB angioplasty (100% Lutonix 0.014 inch drug coated balloon; Bard Lutonix, New Hope, MN, USA) and 395 patients with plain old balloon angioplasty (POBA). The majority of interventions (> 70%) were performed for chronic limb threatening ischaemia. Mean lesion length was 20.8 ± 12.6 cm; 61.2% in the PCB and 66.7% in the POBA group were occlusions. In the PCB group, more procedures were performed for re-stenotic lesions than POBA (28.5 vs. 17.2%). In PSM analysis (128 matched pairs), the primary efficacy endpoint was freedom from clinically driven target lesion revascularisation (CD TLR), which occurred in 70.1% in the PCB and 73.1% in the POBA group at one year (p = .85; McNemar test). Survival analysis suggested lower rates of major amputations in the PCB group in unadjusted (94.4% ± 2.1 vs. 89.2% ± 1.9 in the POBA group) and PSM analyses (97.2% ± 1.6 vs. 89.3% ± 3.5) through two years, while no differences were seen for CD TLR and all cause mortality between the groups. CONCLUSION: In this all comer analysis, PCBs were found to be safe for BTK interventions with a signal towards lower amputation rates but no benefit was seen for repeat revascularisation.


Subject(s)
Angioplasty, Balloon, Coronary , Angioplasty, Balloon , Peripheral Arterial Disease , Humans , Paclitaxel/adverse effects , Cohort Studies , Angioplasty, Balloon/adverse effects , Angioplasty, Balloon, Coronary/methods , Amputation, Surgical , Treatment Outcome , Coated Materials, Biocompatible , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/surgery , Popliteal Artery , Vascular Patency
8.
Ann Vasc Surg ; 78: 170-179, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34474131

ABSTRACT

BACKGROUND: To report technical and clinical 30-day results following treatment with the Zenith Alpha™ abdominal stent graft from the ZEnith alPHa for aneurYsm Repair Registry (ZEPHYR). METHODS: Multicenter, nonrandomized, single arm, core laboratory-controlled, prospective registry collecting data on the Zenith Alpha Abdominal Endovascular Graft being used in subjects with abdominal aortic aneurysms (AAA) from sites in Germany, Belgium, and The Netherlands between December 2016 and December 2019. Inclusion criteria were non-ruptured AAAs with a maximum diameter ≥50 mm or enlargement >5 mm over 6 months with an AAA neck length ≥10 mm (site reported). Primary outcome measure was treatment success at 30 days. Treatment success was defined as a combined endpoint consisting of technical and clinical success. Technical success was defined as successful stent graft delivery and deployment as well as successful removal of the delivery system. Clinical success at 30 days was defined as freedom from type I and III endoleak, aneurysm rupture, conversion to open surgery and stent graft occlusion. RESULTS: Three hundred forty-seven subjects were included from 14 sites with a median age of 73.0 years (IQR 68.0-79.0). Thirty-four patients were female (9.8%). The median AAA diameter was 58.3 mm (IQR 55.0-63.5). The median proximal neck diameter was 23.6 mm (IQR 22.0-25.2) with a median proximal neck length of 24.4 mm (IQR 15.0-34.8) and a median infrarenal neck angulation of 24.5° (IQR 15.0-35.0). The right and left common iliac diameter were 16.1 mm (IQR 14.1-19.4) and 16.2 mm (IQR 14.1-19.1), respectively. The treatment success rate at 30 days was 94.8% (N = 329). Technical success was achieved in 333 patients (96.0%). The clinical success rate at 30 days was 98.8% (N = 343). Three patients had limb occlusions at 30 day follow up (0.9%). One patient had a type Ib endoleak (0.3%). Seventy percent of vascular access approaches were percutaneous. The reintervention rate was 1.7% (N = 6) within 30 days. Indications for reinterventions were a false aneurysm at puncture site (N = 1), limb complications (N = 2), stentgraft-associated renal artery occlusions (N = 2), and an external iliac artery thrombosis (N = 1). CONCLUSIONS: Endovascular aneurysm repair using the Zenith Alpha Abdominal Endovascular Graft is effective in the short term. Long term results will be reported in the future.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Endovascular Procedures/methods , Aged , Aged, 80 and over , Aneurysm, Ruptured , Conversion to Open Surgery , Endoleak , Endovascular Procedures/adverse effects , Female , Humans , Male , Postoperative Complications/epidemiology , Prosthesis Design , Registries , Stents
9.
J Vasc Surg ; 73(6): 1973-1979.e1, 2021 06.
Article in English | MEDLINE | ID: mdl-33278537

ABSTRACT

OBJECTIVE: Type II endoleak (T2EL) is the most common endoleak after endovascular aneurysm repair (EVAR). Its optimal management has been controversially discussed. Thus, preliminary selective embolization of aneurysm sac side branches (ASSBs) has been adopted to prevent T2EL. Our goal was to determine the rate of T2EL and the diameter decrease of abdominal aortic aneurysms (AAAs) after EVAR performed after preemptive embolization of ASSBs. METHODS: From September 2014 to September 2019, 139 patients with AAAs underwent percutaneous ASSB embolization before EVAR. Follow-up imaging studies were performed at 1 and 6 months and annually thereafter. The end points included freedom from T2EL, AAA sac shrinkage, T2EL-related reinterventions, and all-cause mortality. RESULTS: The mean follow-up was 23 ± 16 months (range, 1-61 months). The patients had had a median of five (range, one to eight) patent ASSBs found on preoperative imaging studies. After completion of embolization, 76.4% of the initially patent ASSBs were occluded, with no major procedure-related complications. Follow-up imaging studies showed T2ELs in seven patients (5%), with an aneurysm sac increase seen in six of these patients. The number of ASSBs remaining patent after embolization was the only discriminative factor in patients with and without T2EL. Six T2EL-related reinterventions were performed during follow-up. Most patients (n = 91; 86.7%) had experienced aneurysm sac shrinkage, and the mean diameter reduction was 9.2 ± 7.7 mm (P < .001) in all patients with follow-up data available. One aneurysm-related death occurred within 30 days after EVAR. CONCLUSIONS: Preemptive embolization of ASSBs for patients with AAAs is safe and effective in preventing T2ELs after EVAR. Aneurysm sac shrinkage was observed in a high proportion of patients.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation , Embolization, Therapeutic , Endoleak/prevention & control , Endovascular Procedures , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Embolization, Therapeutic/adverse effects , Embolization, Therapeutic/mortality , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/mortality , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Humans , Male , Protective Factors , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
10.
J Endovasc Ther ; 28(2): 222-228, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33044119

ABSTRACT

PURPOSE: To evaluate the 36-month technical and clinical outcome after implantation of the 25-cm Viabahn endoprosthesis with Propaten bioactive surface in TransAtlantic Inter-Society Consensus II C and D lesions of the superficial femoral and proximal popliteal arteries. MATERIALS AND METHODS: This prospective, multicenter, single-arm trial (ClinicalTrials.gov; identifier NCT01263665) enrolled 71 patients (mean age 66.7±8.3 years; 50 men) with lifestyle-limiting claudication or rest pain (Rutherford category 2-4) and long (>20-cm) lesions of the superficial femoral and proximal popliteal arteries. Primary endpoint was primary patency at 36 months. Secondary endpoints included primary assisted patency; secondary patency; freedom from target lesion revascularization (TLR); freedom from a composite of death, target vessel revascularization (TVR), and amputation; clinical success; and freedom from device fracture. RESULTS: Primary patency estimated by Kaplan-Meier analysis was 40.6% at 36 months. Primary assisted patency and secondary patency estimates were 53.0% and 96.9%, respectively. Within 36 months, 27 patients had to undergo a TLR. Twenty-five patients (35.2%) had a TVR. Freedom from the composite of death, TVR, and amputation endpoint was 44.5%. The estimate of the sustained clinical success with stable or improved Rutherford category was 58.5%. No stent fracture was detected during follow-up. CONCLUSION: The primary patency rate without reintervention after treatment of long femoropopliteal lesions is low. However, secondary patency after implantation of a Viabahn endoprosthesis is high and seems to be superior to the use of other revascularization techniques, resulting in persistent clinical improvement.


Subject(s)
Heparin , Peripheral Arterial Disease , Aged , Femoral Artery/diagnostic imaging , Heparin/adverse effects , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Popliteal Artery/diagnostic imaging , Popliteal Artery/surgery , Prospective Studies , Stents , Treatment Outcome , Vascular Patency
11.
Eur J Vasc Endovasc Surg ; 61(3): 407-412, 2021 03.
Article in English | MEDLINE | ID: mdl-33272811

ABSTRACT

OBJECTIVE: The aim was to describe the outcomes of high risk patients with symptomatic or contained rupture of pararenal (PRAs) and thoraco-abdominal aortic aneurysms (TAAAs) with anatomy unsuitable for commercially available stent grafts who underwent fenestrated endovascular aneurysm repair (FEVAR) using physician modified stent grafts (PMSGs) planned with 3D image analysis software (3DIMAS), and 3D printed aortic models (3DAMs). METHODS: Nineteen consecutive patients (17 male; mean age, 70 ± 9 years) underwent PMSG-FEVAR between 2015 and 2019. 3DAMs to plan the PMSGs were introduced in 2018. End points were all cause mortality, freedom from any endoleak, target vessel patency, and re-intervention. RESULTS: Seven patients (36.8%) were treated with PMSGs using 3DIMAS (three PRAs, three type IV, and one type III TAAAs), and 12 patients (63.2%) received PMSGs using 3DAMs (five PRAs, seven type IV TAAAs). Six patients presented with contained aortic rupture and 13 patients were treated for symptomatic aortic aneurysm. Mean aortic diameter was 72 ± 10 mm. The choice of stent graft for fenestration was the Valiant Captivia Closed Web (Medtronic), except for one patient. Sixteen (84.2%) stent grafts were manufactured with four fenestrations. Technical success was 100%. Seventy-one renovisceral branch vessels were targeted with fenestrations. Mean length of hospital stay was 17.3 ± 10.4 days. Thirty day mortality was 0%. Two patients developed reversible spinal cord injury. Mean follow up was 14.4 months (range 1-52 months). During follow up one non-aneurysm related death occurred, and two successful re-interventions were performed: one to re-establish renal artery patency, and one to treat a type 1c endoleak. CONCLUSION: PMSGs for urgent treatment of pararenal and thoraco-abdominal aortic aneurysms in high risk patients unsuitable for commercially available stent grafts are feasible and safe. 3D printing technology may improve urgent construction of patient specific devices for treatment of complex aortic pathologies and improve outcomes.


Subject(s)
Aneurysm, Ruptured/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Printing, Three-Dimensional , Prosthesis Design , Stents , Aged , Aged, 80 and over , Aneurysm, Ruptured/pathology , Aortic Aneurysm, Thoracic/pathology , Blood Vessel Prosthesis Implantation , Cohort Studies , Female , Humans , Male , Middle Aged , Treatment Outcome
12.
Eur Heart J ; 41(27): 2541-2552, 2020 07 14.
Article in English | MEDLINE | ID: mdl-31989155

ABSTRACT

AIMS: Drug-coated balloons (DCBs) for femoropopliteal interventions have not been tested against each other. We aimed to directly compare efficacy and safety of a high-dose (In.Pact™) vs. low-dose (Ranger™) DCB with nominal paclitaxel densities of 3.5 vs. 2.0 µg/mm2. METHODS AND RESULTS: Within a prospective, multicentre, non-inferiority, clinical trial 414 patients with symptomatic femoropopliteal lesions (Rutherford classification 2-4) were randomly assigned in a 1:1 ratio to endovascular treatment with either high- or low-dose DCB after stratification for lesion length. Primary efficacy and safety endpoints comprised primary patency and freedom from major adverse events (i.e. device and procedure-related deaths through 1 month, major amputations, and clinically driven target lesion revascularization through 12 months). We set a non-inferiority margin of -10% at 12 months. Total occlusions were observed frequently (>40%) and provisional stenting was performed in every fourth intervention. Non-inferiority was determined for both primary efficacy and safety endpoints at 12 months. Primary patency was 81.5% in the high-dose and 83.0% in low-dose DCB group {difference: 1.5% [lower bound of the 90% two-sided confidence interval (CI) -5.2%]; Pnon-inferiority < 0.01}. Freedom from major adverse events was determined in 92.6% in high-dose and in 91.0% in low-dose DCB group [difference -1.6% (lower bound of the 90% two-sided CI -6.5%); Pnon-inferiority < 0.01]. Overall death rate was low (2.0%) and no major amputation occurred. CONCLUSION: Two DCBs with different coating characteristics exhibited comparable results with excellent effectiveness and safety through 12 months for femoropopliteal interventions including a wide range of lesion lengths. CLINICAL TRIAL REGISTRATION: The trial is registered with ClinicalTrials.gov (NCT02701543).


Subject(s)
Angioplasty, Balloon , Cardiovascular Agents , Peripheral Arterial Disease , Pharmaceutical Preparations , Coated Materials, Biocompatible , Femoral Artery , Humans , Paclitaxel , Peripheral Arterial Disease/therapy , Popliteal Artery , Prospective Studies , Time Factors , Treatment Outcome , Vascular Patency
13.
Vasa ; 50(3): 186-192, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33559507

ABSTRACT

Background: Our aim was to determine the rate of ischemic stroke following thoracic endovascular aortic repair (TEVAR) after reducing gas volume released during stentgraft deployment by de-airing of thoracic stentgrafts with high-volume of 0.9% heparinized saline solution. Patients and methods: A single center retrospective analysis of all consecutive patients undergoing TEVAR from 2014 to 2019 was performed. All thoracic stentgrafts were flushed with 120 ml 0.9% heparinized saline solution before implantation, according to our institutional protocol. Endpoints were in-hospital rates of ischemic stroke and spinal cord ischemia (SCI), and all-cause mortality. Results: One hundred and fifty-four patients (mean age: 66.8 ± 13.6 years, 64.9% males) were treated with TEVAR during the study period. Indications for treatment were thoracic aortic aneurysms (n = 75, 48.7%), acute type B aortic dissections (n = 46, 29.9%), aortic arch aneurysms and penetrating aortic ulcers (n = 28, 18.2%), and blunt traumatic aortic injuries (n = 5, 3.2%). Timing of procedure was urgent in 75 patients (48.7%). Proximal landing zone were zone 0-1-2 (n = 75, 48.7%), zone 3 (n = 66, 42.9%) and zone 4 (n = 13, 8.4%). Supra-aortic vessels were revascularized with custom-made fenestrated stentgrafts in 9 patients (5.8%), using chimney technique in 4 patients (2.6%), and with debranching procedures in 19 patients (12.3%). Left subclavian artery was covered without revascularization in 46 patients (29.9%). In-hospital stroke occurred in two patients (1.3%) and SCI in another two patients (1.3%). In-hospital mortality rate was 0.6%. No further in-hospital events were noted. Conclusions: De-airing of stentgrafts with high-volume of 0.9% heparinized saline solution seems to be safe and can be used as an adjunct to keep occurrence of neurological events after TEVAR as low as possible.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Stroke , Aged , Aged, 80 and over , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Female , Humans , Male , Middle Aged , Retrospective Studies , Risk Factors , Saline Solution , Stents , Stroke/etiology , Time Factors , Treatment Outcome
14.
Vasa ; 50(5): 387-393, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34107772

ABSTRACT

Background: To evaluate the safety and effectiveness of preparing instent femoropopliteal lesion with photoablative laser atherectomy or plain balloon angioplasty (POBA) prior to drug-coated balloon (DCB) angioplasty. Patients and methods: The prospective, multicenter, randomized study enrolled patients with Rutherford-Becker-class (RBC) 1 to 5 and instent lesions located in superficial femoral artery and/or popliteal artery above the knee joint. Primary endpoint was target lesion percent stenosis at 1 year as determined by the angiographic core-laboratory. Secondary endpoints included procedural success, major adverse event rate, clinical improvement and improvement in ankle-brachial index (ABI), clinically-driven target lesion revascularization (CD-TLR), and primary patency rate at until 2-year follow-up. Results: The study was terminated prior to the enrollment goal due to slow enrollment. Thirty patients were included in the laser plus DCB cohort and 31 patients in the control cohort. Primary endpoint was not significantly different (p=0.331). Procedural success was 83.3% and 87.1% for the laser plus DCB and the control cohort, respectively. Serious adverse events at 30 days and 1-year were not statistically different between the two cohorts. For the ABI, significant improvements were present at discharge as well as at the follow-up visits. This was also evident for the RBC at the follow-up visits. One- and two-year freedom from CD-TLR was 86.7% vs. 87.1%, and 63.6% vs. 72%, respectively. Duplex derived primary patency was 90% at 6-months, 65.5% at one year and 56.5% at two year for the laser cohort and 90.3%, 75.9% and 53.8% for the control cohort. Conclusions: Safety of instent photoablative laser atherectomy followed by DCB angioplasty is confirmed by this study. Due to the small sample size, no benefit over POBA as vessel preparation could be shown.


Subject(s)
Angioplasty, Balloon , Cardiovascular Agents , Peripheral Arterial Disease , Angioplasty, Balloon/adverse effects , Atherectomy/adverse effects , Coated Materials, Biocompatible , Constriction, Pathologic , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Humans , Paclitaxel/adverse effects , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Popliteal Artery/diagnostic imaging , Popliteal Artery/surgery , Prospective Studies , Time Factors , Treatment Outcome , Vascular Patency
15.
Zentralbl Chir ; 146(5): 486-492, 2021 Oct.
Article in German | MEDLINE | ID: mdl-34666360

ABSTRACT

BACKGROUND: The close anatomical relationship to the visceral vessels renders the treatment of complex throacoabdominal aortic pathologies challenging. In emergent cases, off-the-shelf stent grafts and parallel techniques are feasible treatment options. Alternatively, the treating surgeon can alter a conventional stent graft, creating a so-called surgeon-modified stent graft (SMSG) to adapt it to the complex aortic pathology. The aim of this publication is to present the possibilities and results of this method. RESULTS: The location of SMSG's fenestrations can be determined after manual measurements of the centerline of flow reconstructions of the aortic computed tomography-angiography. The planning of the SMSG can be simplified and standardized by creating personalized 3D aortic models, and by using algorithms for the automated determination of the ideal fenestration positions. Most approved stent grafts can be used as platforms for SMSG. Different manufacturing techniques have been described. In addition to simple fenestrations, mini-cuffs, directional branches, and inner branches are used. Furthermore, diameter reducing ties and preloaded catheters could facilitate the implantation. The treatment of complex aortic pathologies using SMSG has achieved good results, with high technical success rate of 90-100%, and low 30-day mortality, especially when compared to open surgical treatment of similar patients. The rate of endoleak of 0-14% was also acceptable. Long-term durability results after treatment with SMSG are not yet available. CONCLUSION: Surgeon-modified stent grafts are safe and feasible for the endovascular treatment of patients with urgent complex thoracoabdominal aortic pathologies. They represent compassionate use and show promising results in the published literature.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Surgeons , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Humans , Postoperative Complications , Prosthesis Design , Retrospective Studies , Stents , Treatment Outcome
16.
Radiology ; 295(2): 478-487, 2020 05.
Article in English | MEDLINE | ID: mdl-32125256

ABSTRACT

Background Paclitaxel drug-coated balloon (DCB) catheter angioplasty is the preferred treatment for revascularization of femoropopliteal lesions in peripheral artery disease, but mortality is a safety concern. Purpose To assess 2-year efficacy and safety of DCB angioplasty compared with conventional balloon angioplasty (also known as plain old balloon angioplasty or POBA). Materials and Methods This prospective, multicenter, randomized controlled trial enrolled consecutive participants with symptomatic superficial femoral and/or popliteal artery disease at 11 German centers between September 2015 and December 2016. Participants underwent DCB angioplasty or conventional balloon angioplasty. Primary outcome of 6-month late lumen loss showed superiority of DCB angioplasty over conventional balloon angioplasty. Evaluation at 2 years included secondary outcomes of primary patency and target lesion revascularization (TLR) estimated with Kaplan-Meier analysis, clinical and hemodynamic improvement, quality of life, target limb amputation, and all-cause mortality. Results A total of 171 participants (mean age, 69 years ± 8; 111 men) were evaluated. At 2 years, primary patency was achieved in 90.2% (95% confidence interval [CI]: 80.4%, 95.2%) of DCB angioplasty and 62.7% (95% CI: 50.0%, 73.0%) of conventional balloon angioplasty participants (P < .001). Freedom from TLR occurred in 97.2% (95% CI: 89.1%, 99.3%) of DCB angioplasty and 78% (95% CI: 66.5%, 86.0%) of conventional balloon angioplasty participants (P = .001). The groups did not differ in sustained improvement from baseline to 2 years in Rutherford-Becker category (row mean scores difference, 1.7; P = .19) and showed no difference in mean improvement in the Walking Impairment Questionnaire score (-0.8%; 95% CI: -11.8%, 10.2%; P = .88), EuroQol Group's five-dimension index of quality of life (-0.06; 95% CI: -0.17, 0.03; P = .20), or ankle-brachial index (0.03; 95% CI: -0.08, 0.14; P = .57). No major amputation was necessary. One DCB angioplasty and two conventional balloon angioplasty participants died (risk ratio, 0.48; 95% CI: 0.04, 5.10). Conclusion At 2 years after paclitaxel drug-coated balloon (DCB) angioplasty, primary patency and freedom from target lesion revascularization remained superior compared with conventional balloon angioplasty. DCB angioplasty resulted in sustained clinical and hemodynamic improvement with no increased risk of mortality. © RSNA, 2020 Online supplemental material in available for this article.


Subject(s)
Angioplasty, Balloon/methods , Lower Extremity/blood supply , Lower Extremity/diagnostic imaging , Paclitaxel/administration & dosage , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Aged , Coated Materials, Biocompatible , Female , Femoral Artery , Germany , Humans , Male , Popliteal Artery , Prospective Studies , Quality of Life , Single-Blind Method , Vascular Patency
17.
J Vasc Surg ; 72(5): 1648-1658.e2, 2020 11.
Article in English | MEDLINE | ID: mdl-32276015

ABSTRACT

OBJECTIVE: The objective of this study was to evaluate the 1-year safety and effectiveness outcomes associated with the PQ Bypass DETOUR System (PQ Bypass, Milpitas, Calif) for the percutaneous bypass of long-segment femoropopliteal occlusive disease. METHODS: This prospective, single-arm, multicenter trial enrolled patients with long-segment femoropopliteal arterial disease. The DETOUR System percutaneously deploys modular stent grafts to bypass femoropopliteal lesions through a transvenous route. Eligible patients included those with TransAtlantic Inter-Society Consensus C and D lesions >100 mm in length. The primary safety end point was the major adverse event (MAE) rate through 1 month, defined as the composite of death, clinically driven target vessel revascularization (CD-TVR), or major amputation. The primary effectiveness end point was stent graft patency through 6 months, defined as freedom from stenosis ≥50%, occlusion, or CD-TVR. RESULTS: During a 24-month period, 78 patients (82 limbs) were enrolled. The average core laboratory-measured lesion length was 371 ± 55 mm; 79 of 82 lesions (96%) were chronic total occlusions, and 55 of 82 lesions (67%) had severe calcification. The rates of technical and procedural success measured during the index procedure were both 96%, with satisfactory delivery and deployment of the device without MAEs in 79 of 82 limbs. Through 1 month, there were no deaths or amputations; CD-TVRs occurred in 2 of 81 limbs (3%), and freedom from MAEs was 98% (79/81). The 1-year Kaplan-Meier primary, assisted primary, and secondary patency rates were 81% ± 4%, 82% ± 4%, and 90% ± 3%, respectively. The ankle-brachial index increased an average of 0.25 ± 0.27 between baseline and 1 year (P < .001). Through 1 year, the Kaplan-Meier estimates of freedom from stent graft thrombosis, CD-TVR, and MAE were 84% ± 4%, 85% ± 4%, and 84% ± 4%, respectively. At 1 year, the Rutherford class improved in 77 of 80 limbs (96%), and 65 of 80 (81%) were asymptomatic. Deep venous thrombosis developed in 2 of 79 target limbs (3%) through 1 year, both at the femoropopliteal vein level. There were no instances of pulmonary embolism. CONCLUSIONS: The 1-year results from the DETOUR I trial show that the PQ Bypass DETOUR System is a safe and effective percutaneous treatment option for patients with longer, severely calcified, above-knee femoropopliteal lesions.


Subject(s)
Arterial Occlusive Diseases/surgery , Endovascular Procedures/adverse effects , Intermittent Claudication/surgery , Peripheral Arterial Disease/surgery , Postoperative Complications/epidemiology , Adolescent , Adult , Aged , Aged, 80 and over , Amputation, Surgical/statistics & numerical data , Arterial Occlusive Diseases/complications , Arterial Occlusive Diseases/mortality , Endovascular Procedures/instrumentation , Female , Femoral Artery/surgery , Humans , Intermittent Claudication/etiology , Intermittent Claudication/mortality , Kaplan-Meier Estimate , Male , Middle Aged , Peripheral Arterial Disease/complications , Peripheral Arterial Disease/mortality , Popliteal Artery/surgery , Postoperative Complications/etiology , Prospective Studies , Stents/adverse effects , Treatment Outcome , Vascular Patency , Young Adult
18.
J Endovasc Ther ; 27(2): 287-295, 2020 04.
Article in English | MEDLINE | ID: mdl-31997715

ABSTRACT

Purpose: To report the 12-month results of a multicenter, prospective, randomized controlled trial to determine if the ZILVER PTX paclitaxel-eluting stent was noninferior in terms of safety and efficacy compared with surgical bypass. Materials and Methods: This is a study in symptomatic TransAtlantic Inter-Society Consensus (TASC) C and D femoropopliteal lesions comparing endovascular ZILVER PTX stenting vs surgical bypass surgery using a prosthetic graft (ClinicalTrials.gov identifier NCT01952457). Between October 2013 and July 2017, 220 patients (mean age 68.6±10.5 years; 159 men) were enrolled and randomized to the ZILVER PTX treatment group (113, 51.4%) or the bypass treatment group (107, 48.6%). Most of the lesions were occlusions (208, 94.5%); the mean lesion length was 247.1±69.3 mm. The primary outcome measure was primary patency at 12 months, defined as no evidence of binary restenosis or occlusion within the target lesion or bypass graft based on a duplex-derived peak systolic velocity ratio <2.4 and no clinically-driven target lesion revascularization (TLR) in endovascular cases or reintervention to restore flow in the bypass. Results: The estimated 12-month primary patency rate was 74.5% (95% CI 66.3% to 82.7%) for the ZILVER PTX group vs 72.5% (95% CI 63.7% to 81.3%) for the bypass arm (p=0.998). Freedom from TLR at 12 months was 80.9% (95% CI 73.3% to 88.5%) for the ZILVER PTX group vs 76.2% (95% CI 68.0% to 84.4%) for the bypass group (p=0.471). The 30-day complication rate was significantly lower in the ZILVER PTX group (4.4% vs 11.3%, p=0.004). Also, procedure time and hospital stay were significantly shorter in the ZILVER PTX group (p<0.001 for both). Conclusion: With noninferior patency results, a lower complication rate, and shorter procedures and hospital stays, paclitaxel-eluting stenting might become a recommended treatment for long TASC C and D femoropopliteal lesions.


Subject(s)
Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Drug-Eluting Stents , Endovascular Procedures/instrumentation , Femoral Artery/surgery , Paclitaxel/administration & dosage , Peripheral Arterial Disease/therapy , Popliteal Artery/surgery , Aged , Aged, 80 and over , Blood Vessel Prosthesis Implantation/adverse effects , Brazil , Cardiovascular Agents/therapeutic use , Endovascular Procedures/adverse effects , Europe , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Humans , Length of Stay , Male , Middle Aged , Paclitaxel/adverse effects , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Popliteal Artery/diagnostic imaging , Popliteal Artery/physiopathology , Prospective Studies , Prosthesis Design , Recurrence , Risk Factors , Time Factors , Treatment Outcome , Vascular Patency
19.
Bioconjug Chem ; 30(10): 2664-2674, 2019 10 16.
Article in English | MEDLINE | ID: mdl-31532989

ABSTRACT

Common interventional therapies for cardiovascular occlusive diseases, such as the implantation of stents, are at risk of complications like thrombosis or restenosis. Drug-eluting stents have improved patency but simultaneously worsen the endothelialization of the implant. Here, we present a novel peptide coating derived from three proteins of the extracellular matrix named fibronectin, laminin, and elastin. Their active sequences RGD, SIKVAV, and VGVAPG were immobilized onto titanium surfaces by a carrier peptide containing l-3,4-dihydroxyphenylalanine (DOPA). Simultaneous functionalization of the carrier peptide with cyclic c[RGDfK] and SIKVAV had the most potent influence on adhesion, proliferation, viability, and angiogenesis of endothelial cells. By presentation of two adhesion peptides in one molecule, a synergistic enhancement of cell-surface interactions was achieved. Overall, this work clearly demonstrates the advantages of spatially defined peptide coatings for the endothelialization of titanium and thus describes a promising approach for the coating of stents.


Subject(s)
Cell Adhesion/drug effects , Human Umbilical Vein Endothelial Cells/cytology , Human Umbilical Vein Endothelial Cells/drug effects , Oligopeptides/chemistry , Oligopeptides/pharmacology , Titanium/chemistry , Amino Acid Sequence , Animals , Bivalvia , Cell Differentiation/drug effects , Cell Proliferation/drug effects , Cell Survival/drug effects , Humans , Stents , Surface Properties
20.
Catheter Cardiovasc Interv ; 93(2): 335-342, 2019 02 01.
Article in English | MEDLINE | ID: mdl-30474206

ABSTRACT

OBJECTIVE: DISRUPT PAD II was designed to evaluate the safety and performance of intravascular lithotripsy (IVL), a novel approach using pulsatile sonic pressure waves, to modify intimal and medial calcium in stenotic peripheral arteries. BACKGROUND: Vascular calcification restricts vessel expansion, increases the risk of vascular complications, and may impair the effect of anti-proliferative therapy. METHODS: Disrupt PAD II was a non-randomized, multi-center study that enrolled 60 subjects with complex, calcified peripheral arterial stenosis at eight sites. Patients were treated with IVL and followed to 12-months. The primary safety endpoint was major adverse events (MAE) through 30 days. The primary effectiveness endpoint was patency at 12 months as adjudicated by duplex ultrasonography (DUS). Key secondary endpoints included acute procedure success, freedom from re-intervention, and functional outcomes. RESULTS: Between June 2015 and December 2015, subjects with moderate or severe calcified arterial lesions were enrolled. The final residual stenosis was 24.2%, with an average acute gain of 3.0 mm. The 30-day MAE rate was 1.7% with one grade D dissection that resolved following stent placement. Primary patency at 12 months was 54.5%, and clinically driven TLR at 12 months was 20.7%. Optimal IVL technique defined by correct balloon sizing and avoiding therapeutic miss, improved 12-month primary patency and TLR outcomes to 62.9% and 8.6%, respectively. CONCLUSIONS: IVL demonstrated compelling safety with minimal vessel injury, and minimal use of adjunctive stents in a complex, difficult to treat population.


Subject(s)
Femoral Artery , Lithotripsy/methods , Peripheral Arterial Disease/therapy , Popliteal Artery , Ultrasonic Therapy , Vascular Calcification/therapy , Aged , Aged, 80 and over , Europe , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Humans , Lithotripsy/adverse effects , Male , Middle Aged , New Zealand , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Popliteal Artery/diagnostic imaging , Popliteal Artery/physiopathology , Progression-Free Survival , Prospective Studies , Retreatment , Risk Factors , Severity of Illness Index , Time Factors , Ultrasonic Therapy/adverse effects , Vascular Calcification/diagnostic imaging , Vascular Calcification/physiopathology , Vascular Patency
SELECTION OF CITATIONS
SEARCH DETAIL