1.
J Neuroeng Rehabil ; 21(1): 70, 2024 05 03.
Article in English | MEDLINE | ID: mdl-38702813

ABSTRACT

Despite its rich history of success in controlling powered prostheses and emerging commercial interests in ubiquitous computing, myoelectric control continues to suffer from a lack of robustness. In particular, EMG-based systems often degrade over prolonged use resulting in tedious recalibration sessions, user frustration, and device abandonment. Unsupervised adaptation is one proposed solution that updates a model's parameters over time based on its own predictions during real-time use to maintain robustness without requiring additional user input or dedicated recalibration. However, these strategies can actually accelerate performance deterioration when they begin to classify (and thus adapt) incorrectly, defeating their own purpose. To overcome these limitations, we propose a novel adaptive learning strategy, Context-Informed Incremental Learning (CIIL), that leverages in situ context to better inform the prediction of pseudo-labels. In this work, we evaluate these CIIL strategies in an online target acquisition task for two use cases: (1) when there is a lack of training data and (2) when a drastic and enduring alteration in the input space has occurred. A total of 32 participants were evaluated across the two experiments. The results show that the CIIL strategies significantly outperform the current state-of-the-art unsupervised high-confidence adaptation and outperform models trained with the conventional screen-guided training approach, even after a 45-degree electrode shift (p < 0.05). Consequently, CIIL has substantial implications for the future of myoelectric control, potentially reducing the training burden while bolstering model robustness, and leading to improved real-time control.


Subject(s)
Electromyography , Humans , Male , Adult , Female , Young Adult , Learning/physiology , Artificial Limbs , Machine Learning , Psychomotor Performance/physiology
2.
Sensors (Basel) ; 22(23)2022 Nov 29.
Article in English | MEDLINE | ID: mdl-36501983

ABSTRACT

The monitoring of emotional state is important in the prevention and management of mental health problems and is increasingly being used to support affective computing. As such, researchers are exploring various modalities from which emotion can be inferred, such as through facial images or via electroencephalography (EEG) signals. Current research commonly investigates the performance of machine-learning-based emotion recognition systems by exposing users to stimuli that are assumed to elicit a single unchanging emotional response. Moreover, in order to demonstrate better results, many models are tested in evaluation frameworks that do not reflect realistic real-world implementations. Consequently, in this paper, we explore the design of EEG-based emotion recognition systems using longer, variable stimuli using the publicly available AMIGOS dataset. Feature engineering and selection results are evaluated across four different cross-validation frameworks, including versions of leave-one-movie-out (testing with a known user, but a previously unseen movie), leave-one-person-out (testing with a known movie, but a previously unseen person), and leave-one-person-and-movie-out (testing on both a new user and new movie). Results of feature selection lead to a 13% absolute improvement over comparable previously reported studies, and demonstrate the importance of evaluation framework on the design and performance of EEG-based emotion recognition systems.


Subject(s)
Emotions , Recognition, Psychology , Humans , Electroencephalography , Face , Engineering
3.
Sensors (Basel) ; 20(3)2020 Jan 23.
Article in English | MEDLINE | ID: mdl-31979224

ABSTRACT

Due to the increasing rates of chronic diseases and an aging population, the use of assistive devices for ambulation is expected to grow rapidly over the next several years. Instrumenting these devices has been proposed as a non-invasive way to proactively monitor changes in gait due to the presence of pain or a condition in outdoor and indoor environments. In this paper, we evaluated the effectiveness of a multi-sensor cane in detecting changes in gait due to the presence of simulated gait abnormalities, walking terrains, impaired vision, and incorrect cane lengths. The effectiveness of the instrumented cane was compared with the results obtained directly from a shank-mounted inertial measurement unit. Results from 30 healthy participants obtained while simulating gait abnormalities and walking over different terrains demonstrated the ability of the cane to reliably and effectively discriminate among these walking conditions. Moreover, the results obtained while walking with impaired vision and incorrect cane lengths indicate the ability of cane to detect changes in gait during these scenarios as well.


Subject(s)
Canes , Gait/physiology , Movement Disorders/physiopathology , Walking/physiology , Adolescent , Adult , Algorithms , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Child , Female , Humans , Male , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Young Adult
4.
Sensors (Basel) ; 20(6)2020 Mar 13.
Article in English | MEDLINE | ID: mdl-32183215

ABSTRACT

This manuscript presents a hybrid study of a comprehensive review and a systematic(research) analysis. Myoelectric control is the cornerstone ofmany assistive technologies used in clinicalpractice, such as prosthetics and orthoses, and human-computer interaction, such as virtual reality control.Although the classification accuracy of such devices exceeds 90% in a controlled laboratory setting,myoelectric devices still face challenges in robustness to variability of daily living conditions.The intrinsic physiological mechanisms limiting practical implementations of myoelectric deviceswere explored: the limb position effect and the contraction intensity effect. The degradationof electromyography (EMG) pattern recognition in the presence of these factors was demonstratedon six datasets, where classification performance was 13% and 20% lower than the controlledsetting for the limb position and contraction intensity effect, respectively. The experimental designsof limb position and contraction intensity literature were surveyed. Current state-of-the-art trainingstrategies and robust algorithms for both effects were compiled and presented. Recommendationsfor future limb position effect studies include: the collection protocol providing exemplars of at least 6positions (four limb positions and three forearm orientations), three-dimensional space experimentaldesigns, transfer learning approaches, and multi-modal sensor configurations. Recommendationsfor future contraction intensity effect studies include: the collection of dynamic contractions, nonlinearcomplexity features, and proportional control.


Subject(s)
Electromyography/trends , Movement/physiology , Muscle, Skeletal/physiology , Pattern Recognition, Visual/physiology , Artificial Limbs , Forearm/physiology , Humans , Muscle, Skeletal/diagnostic imaging , Pattern Recognition, Automated , Prosthesis Design , User-Computer Interface
5.
Sensors (Basel) ; 19(21)2019 Oct 28.
Article in English | MEDLINE | ID: mdl-31661761

ABSTRACT

Many biometric systems based on physiological traits such as ones facial characteristics, iris, and fingerprint have been developed for authentication purposes. Such security systems, however, commonly suffer from impersonation attacks such as obfuscation, abrasion, latent samples, and covert attack. More conventional behavioral methods, such as passwords and signatures, suffer from similar issues and can easily be spoofed. With growing levels of private data readily available across the internet, a more robust authentication system is needed for use in emerging technologies and mobile applications. In this paper, we present a novel multimodal biometric user authentication framework by combining the behavioral dynamic signature with the the physiological electroencephalograph (EEG) to restrict unauthorized access. EEG signals of 33 genuine users were collected while signing on their mobile phones. The recorded sequences were modeled using a bidirectional long short-term memory neural network (BLSTM-NN) based sequential classifier to accomplish person identification and verification. An accuracy of 98.78% was obtained for identification using decision fusion of dynamic signatures and EEG signals. The robustness of the framework was also tested against 1650 impersonation attempts made by 25 forged users by imitating the dynamic signatures of genuine users. Verification performance was measured using detection error tradeoff (DET) curves and half total error rate (HTER) security matrices using true positive rate (TPR) and false acceptance rate (FAR), resulting in 3.75% FAR and 1.87% HTER with 100% TPR for forgery attempts.


Subject(s)
Biometric Identification/methods , Computer Security , Adult , Brain/physiology , Cell Phone , Density Functional Theory , Electroencephalography , Female , Humans , Male , Neural Networks, Computer , Young Adult
6.
J Neuroeng Rehabil ; 15(1): 70, 2018 07 31.
Article in English | MEDLINE | ID: mdl-30064477

ABSTRACT

BACKGROUND: The loss of an arm presents a substantial challenge for upper limb amputees when performing activities of daily living. Myoelectric prosthetic devices partially replace lost hand functions; however, lack of sensory feedback and strong understanding of the myoelectric control system prevent prosthesis users from interacting with their environment effectively. Although most research in augmented sensory feedback has focused on real-time regulation, sensory feedback is also essential for enabling the development and correction of internal models, which in turn are used for planning movements and reacting to control variability faster than otherwise possible in the presence of sensory delays. METHODS: Our recent work has demonstrated that audio-augmented feedback can improve both performance and internal model strength for an abstract target acquisition task. Here we use this concept in controlling a robotic hand, which has inherent dynamics and variability, and apply it to a more functional grasp-and-lift task. We assessed internal model strength using psychophysical tests and used an instrumented Virtual Egg to assess performance. RESULTS: Results obtained from 14 able-bodied subjects show that a classifier-based controller augmented with audio feedback enabled stronger internal model (p = 0.018) and better performance (p = 0.028) than a controller without this feedback. CONCLUSIONS: We extended our previous work and accomplished the first steps on a path towards bridging the gap between research and clinical usability of a hand prosthesis. The main goal was to assess whether the ability to decouple internal model strength and motion variability using the continuous audio-augmented feedback extended to real-world use, where the inherent mechanical variability and dynamics in the mechanisms may contribute to a more complicated interplay between internal model formation and motion variability. We concluded that benefits of using audio-augmented feedback for improving internal model strength of myoelectric controllers extend beyond a virtual target acquisition task to include control of a prosthetic hand.


Subject(s)
Artificial Limbs , Exoskeleton Device , Feedback, Sensory/physiology , Robotics/methods , Support Vector Machine , Adult , Electromyography/methods , Female , Hand/physiopathology , Hand Strength/physiology , Humans , Male
7.
Sensors (Basel) ; 18(5)2018 May 18.
Article in English | MEDLINE | ID: mdl-29783659

ABSTRACT

Specialized myoelectric sensors have been used in prosthetics for decades, but, with recent advancements in wearable sensors, wireless communication and embedded technologies, wearable electromyographic (EMG) armbands are now commercially available for the general public. Due to physical, processing, and cost constraints, however, these armbands typically sample EMG signals at a lower frequency (e.g., 200 Hz for the Myo armband) than their clinical counterparts. It remains unclear whether existing EMG feature extraction methods, which largely evolved based on EMG signals sampled at 1000 Hz or above, are still effective for use with these emerging lower-bandwidth systems. In this study, the effects of sampling rate (low: 200 Hz vs. high: 1000 Hz) on the classification of hand and finger movements were evaluated for twenty-six different individual features and eight sets of multiple features using a variety of datasets comprised of both able-bodied and amputee subjects. The results show that, on average, classification accuracies drop significantly ( p.


Subject(s)
Biosensing Techniques , Electromyography/methods , Movement/physiology , Wearable Electronic Devices , Amputees , Female , Hand , Humans , Male , Pattern Recognition, Automated , Prostheses and Implants
8.
Sensors (Basel) ; 18(9)2018 Sep 06.
Article in English | MEDLINE | ID: mdl-30200595

ABSTRACT

Individuals with mobility impairments related to age, injury, or disease, often require the help of an assistive device (AD) such as a cane to ambulate, increase safety, and improve overall stability. Instrumenting these devices has been proposed as a non-invasive way to proactively monitor an individual's reliance on the AD while also obtaining information about behaviors and changes in gait. A critical first step in the analysis of these data, however, is the accurate processing and segmentation of the sensor data to extract relevant gait information. In this paper, we present a highly accurate multi-sensor-based gait segmentation algorithm that is robust to a variety of walking conditions using an AD. A matched filtering approach based on loading information is used in conjunction with an angular rate reversal and peak detection technique, to identify important gait events. The algorithm is tested over a variety of terrains using a hybrid sensorized cane, capable of measuring loading, mobility, and stability information. The reliability and accuracy of the proposed multi-sensor matched filter (MSMF) algorithm is compared with variations of the commonly employed gyroscope peak detection (GPD) algorithm. Results of an experiment with a group of 30 healthy participants walking over various terrains demonstrated the ability of the proposed segmentation algorithm to reliably and accurately segment gait events.


Subject(s)
Algorithms , Gait , Adolescent , Adult , Female , Healthy Volunteers , Humans , Male , Reproducibility of Results , Young Adult
9.
Front Bioeng Biotechnol ; 12: 1463377, 2024.
Article in English | MEDLINE | ID: mdl-39380895

ABSTRACT

Myoelectric control, the use of electromyogram (EMG) signals generated during muscle contractions to control a system or device, is a promising input, enabling always-available control for emerging ubiquitous computing applications. However, its widespread use has historically been limited by the need for user-specific machine learning models because of behavioural and physiological differences between users. Leveraging the publicly available 612-user EMG-EPN612 dataset, this work dispels this notion, showing that true zero-shot cross-user myoelectric control is achievable without user-specific training. By taking a discrete approach to classification (i.e., recognizing the entire dynamic gesture as a single event), a classification accuracy of 93.0% for six gestures was achieved on a set of 306 unseen users, showing that big data approaches can enable robust cross-user myoelectric control. By organizing the results into a series of mini-studies, this work provides an in-depth analysis of discrete cross-user models to answer unknown questions and uncover new research directions. In particular, this work explores the number of participants required to build cross-user models, the impact of transfer learning for fine-tuning these models, and the effects of under-represented end-user demographics in the training data, among other issues. Additionally, in order to further evaluate the performance of the developed cross-user models, a completely new dataset was created (using the same recording device) that includes known covariate factors such as cross-day use and limb-position variability. The results show that the large data models can effectively generalize to new datasets and mitigate the impact of common confounding factors that have historically limited the adoption of EMG-based inputs.

10.
J Neural Eng ; 21(4)2024 Aug 22.
Article in English | MEDLINE | ID: mdl-39079541

ABSTRACT

Objective.The use of electromyogram (EMG) signals recorded from the wrist is emerging as a desirable input modality for human-machine interaction (HMI). Although forearm-based EMG has been used for decades in prosthetics, there has been comparatively little prior work evaluating the performance of wrist-based control, especially in online, user-in-the-loop studies. Furthermore, despite different motivating use cases for wrist-based control, research has mostly adopted legacy prosthesis control evaluation frameworks.Approach.Gaining inspiration from rhythm games and the Schmidt's law speed-accuracy tradeoff, this work proposes a new temporally constrained evaluation environment with a linearly increasing difficulty to compare the online usability of wrist and forearm EMG. Compared to the more commonly used Fitts' Law-style testing, the proposed environment may offer different insights for emerging use cases of EMG as it decouples the machine learning algorithm's performance from proportional control, is easily generalizable to different gesture sets, and enables the extraction of a wide set of usability metrics that describe a users ability to successfully accomplish a task at a certain time with different levels of induced stress.Main results.The results suggest that wrist EMG-based control is comparable to that of forearm EMG when using traditional prosthesis control gestures and can even be better when using fine finger gestures. Additionally, the results suggest that as the difficulty of the environment increased, the online metrics and their correlation to the offline metrics decreased, highlighting the importance of evaluating myoelectric control in real-time evaluations over a range of difficulties.Significance.This work provides valuable insights into the future design and evaluation of myoelectric control systems for emerging HMI applications.


Subject(s)
Electromyography , Forearm , Wrist , Humans , Electromyography/methods , Forearm/physiology , Wrist/physiology , Male , Adult , Female , Young Adult , Online Systems , Video Games , Algorithms
11.
J Neural Eng ; 21(3)2024 May 17.
Article in English | MEDLINE | ID: mdl-38722304

ABSTRACT

Discrete myoelectric control-based gesture recognition has recently gained interest as a possible input modality for many emerging ubiquitous computing applications. Unlike the continuous control commonly employed in powered prostheses, discrete systems seek to recognize the dynamic sequences associated with gestures to generate event-based inputs. More akin to those used in general-purpose human-computer interaction, these could include, for example, a flick of the wrist to dismiss a phone call or a double tap of the index finger and thumb to silence an alarm. Moelectric control systems have been shown to achieve near-perfect classification accuracy, but in highly constrained offline settings. Real-world, online systems are subject to 'confounding factors' (i.e. factors that hinder the real-world robustness of myoelectric control that are not accounted for during typical offline analyses), which inevitably degrade system performance, limiting their practical use. Although these factors have been widely studied in continuous prosthesis control, there has been little exploration of their impacts on discrete myoelectric control systems for emerging applications and use cases. Correspondingly, this work examines, for the first time, three confounding factors and their effect on the robustness of discrete myoelectric control: (1)limb position variability, (2)cross-day use, and a newly identified confound faced by discrete systems (3)gesture elicitation speed. Results from four different discrete myoelectric control architectures: (1) Majority Vote LDA, (2) Dynamic Time Warping, (3) an LSTM network trained with Cross Entropy, and (4) an LSTM network trained with Contrastive Learning, show that classification accuracy is significantly degraded (p<0.05) as a result of each of these confounds. This work establishes that confounding factors are a critical barrier that must be addressed to enable the real-world adoption of discrete myoelectric control for robust and reliable gesture recognition.


Subject(s)
Electromyography , Gestures , Pattern Recognition, Automated , Humans , Electromyography/methods , Male , Pattern Recognition, Automated/methods , Female , Adult , Young Adult , Artificial Limbs
12.
Article in English | MEDLINE | ID: mdl-38194392

ABSTRACT

In the field of EMG-based force modeling, the ability to generalize models across individuals could play a significant role in its adoption across a range of applications, including assistive devices, robotic and rehabilitation devices. However, current studies have predominately focused on intra-subject modeling, largely neglecting the burden of end-user data acquisition. In this work, we propose the use of transfer learning (TL) to generalize force modeling to a new user by first establishing a baseline model trained using other users' data, and then adapting to the end-user using a small amount of new data (only 10% , 20% , and 40% of the new user data). Using a deep multimodal convolutional neural network, consisting of two CNN models, one with high-density (HD) EMG and one with motion data recorded by an Inertial Measurement Unit (IMU), our proposed TL technique significantly improved force modeling compared to leave-one-subject-out (LOSO) and even intra-subject scenarios. The TL approach increased the average R squared values of the force modeling task by 60.81%, 190.53%, and 199.79% compared to the LOSO case, and by 13.4%, 36.88%, and 45.51% compared to the intra-subject case for isotonic, isokinetic and dynamic conditions, respectively. These results show that it is possible to adapt to a new user with minimal data while improving performance significantly compared to the intra-subject scenario. We also show that TL can be used to generalize on a new experimental condition for a new user.


Subject(s)
Neural Networks, Computer , Self-Help Devices , Humans , Electromyography/methods , Upper Extremity , Machine Learning
13.
J Breath Res ; 18(2)2024 03 13.
Article in English | MEDLINE | ID: mdl-38382095

ABSTRACT

Detection of the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) relies on real-time-reverse-transcriptase polymerase chain reaction (RT-PCR) on nasopharyngeal swabs. The false-negative rate of RT-PCR can be high when viral burden and infection is localized distally in the lower airways and lung parenchyma. An alternate safe, simple and accessible method for sampling the lower airways is needed to aid in the early and rapid diagnosis of COVID-19 pneumonia. In a prospective unblinded observational study, patients admitted with a positive RT-PCR and symptoms of SARS-CoV-2 infection were enrolled from three hospitals in Ontario, Canada. Healthy individuals or hospitalized patients with negative RT-PCR and without respiratory symptoms were enrolled into the control group. Breath samples were collected and analyzed by laser absorption spectroscopy (LAS) for volatile organic compounds (VOCs) and classified by machine learning (ML) approaches to identify unique LAS-spectra patterns (breathprints) for SARS-CoV-2. Of the 135 patients enrolled, 115 patients provided analyzable breath samples. Using LAS-breathprints to train ML classifier models resulted in an accuracy of 72.2%-81.7% in differentiating between SARS-CoV2 positive and negative groups. The performance was consistent across subgroups of different age, sex, body mass index, SARS-CoV-2 variants, time of disease onset and oxygen requirement. The overall performance was higher than compared to VOC-trained classifier model, which had an accuracy of 63%-74.7%. This study demonstrates that a ML-based breathprint model using LAS analysis of exhaled breath may be a valuable non-invasive method for studying the lower airways and detecting SARS-CoV-2 and other respiratory pathogens. The technology and the ML approach can be easily deployed in any setting with minimal training. This will greatly improve access and scalability to meet surge capacity; allow early and rapid detection to inform therapy; and offers great versatility in developing new classifier models quickly for future outbreaks.


Subject(s)
COVID-19 , Humans , SARS-CoV-2 , Prospective Studies , RNA, Viral , Breath Tests , Machine Learning
14.
J Neurophysiol ; 109(11): 2658-65, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23515790

ABSTRACT

In this paper, the predictive capability of surface and untargeted intramuscular electromyography (EMG) was compared with respect to wrist-joint torque to quantify which type of measurement better represents joint torque during multiple degrees-of-freedom (DoF) movements for possible application in prosthetic control. Ten able-bodied subjects participated in the study. Surface and intramuscular EMG was recorded concurrently from the right forearm. The subjects were instructed to track continuous contraction profiles using single and combined DoF in two trials. The association between torque and EMG was assessed using an artificial neural network. Results showed a significant difference between the two types of EMG (P < 0.007) for all performance metrics: coefficient of determination (R(2)), Pearson correlation coefficient (PCC), and root mean square error (RMSE). The performance of surface EMG (R(2) = 0.93 ± 0.03; PCC = 0.98 ± 0.01; RMSE = 8.7 ± 2.1%) was found to be superior compared with intramuscular EMG (R(2) = 0.80 ± 0.07; PCC = 0.93 ± 0.03; RMSE = 14.5 ± 2.9%). The higher values of PCC compared with R(2) indicate that both methods are able to track the torque profile well but have some trouble (particularly intramuscular EMG) in estimating the exact amplitude. The possible cause for the difference, thus the low performance of intramuscular EMG, may be attributed to the very high selectivity of the recordings used in this study.


Subject(s)
Motor Activity , Muscle, Skeletal/physiology , Torque , Wrist/physiology , Adult , Electromyography , Female , Humans , Male , Muscle Contraction , Neural Networks, Computer
15.
J Prosthet Orthot ; 25(2): 76-83, 2013 Apr 01.
Article in English | MEDLINE | ID: mdl-23894224

ABSTRACT

The performance of pattern recognition based myoelectric control has seen significant interest in the research community for many years. Due to a recent surge in the development of dexterous prosthetic devices, determining the clinical viability of multifunction myoelectric control has become paramount. Several factors contribute to differences between offline classification accuracy and clinical usability, but the overriding theme is that the variability of the elicited patterns increases greatly during functional use. Proportional control has been shown to greatly improve the usability of conventional myoelectric control systems. Typically, a measure of the amplitude of the electromyogram (a rectified and smoothed version) is used to dictate the velocity of control of a device. The discriminatory power of myoelectric pattern classifiers, however, is also largely based on amplitude features of the electromyogram. This work presents an introductory look at the effect of contraction strength and proportional control on pattern recognition based control. These effects are investigated using typical pattern recognition data collection methods as well as a real-time position tracking test. Training with dynamically force varying contractions and appropriate gain selection is shown to significantly improve (p<0.001) the classifier's performance and tolerance to proportional control.

16.
IEEE J Biomed Health Inform ; 27(12): 6051-6061, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37721893

ABSTRACT

Post-processing techniques have been shown to improve the quality of the decision stream generated by classifiers used in pattern-recognition-based myoelectric control. However, these techniques have largely been tested individually and on well-behaved, stationary data, failing to fully evaluate their trade-offs between smoothing and latency during dynamic use. Correspondingly, in this work, we survey and compare 8 different post-processing and decision stream improvement schemes in the context of continuous and dynamic class transitions: majority vote, Bayesian fusion, onset locking, outlier detection, confidence-based rejection, confidence scaling, prior adjustment, and adaptive windowing. We then propose two new temporally aware post-processing schemes that use changes in the decision and confidence streams to better reject uncertain decisions. Our decision-change informed rejection (DCIR) approach outperforms existing schemes during both steady-state and transitions based on error rates and decision stream volatility whether using conventional or deep classifiers. These results suggest that added robustness can be gained by appropriately leveraging temporal context in myoelectric control.


Subject(s)
Pattern Recognition, Automated , Humans , Bayes Theorem , Electromyography/methods , Pattern Recognition, Automated/methods
17.
Article in English | MEDLINE | ID: mdl-38083158

ABSTRACT

Deep learning (DL) has become a powerful tool in many image classification applications but often requires large training sets to achieve high accuracy. For applications where the available data are limited, this can become a severely limiting factor in model performance. To address this limitation, feature learning network approaches that integrate traditional feature extraction methods with DL frameworks have been proposed. In this study, the performances of traditional methods: discrete wavelet transform (DWT), discrete cosine transform (DCT), independent component analysis (ICA), and principal component analysis (PCA); and their corresponding feature networks based on a convolutional neural network (CNN) framework: ScatNet (wavelet scattering network), DCTNet, ICANet, and PCANet, were investigated for use in pressure-based footstep recognition when the limited sample size is available for person authentication. The results show that the feature learning networks (90.6% accuracy) achieved significantly better performance on average than the conventional feature extraction methods (79.7% accuracy) (p < 0.05). Among the different feature networks, PCANet provided the best verification performance, with an accuracy of 92.2%. Feature learning networks are simple and effective approaches that can be a promising solution for applications like floor-based gait recognition in a security access scenario (such as workspace environment and border control) when small amounts of data are available for training models to differentiate between a larger group of users.


Subject(s)
Gait , Neural Networks, Computer , Humans , Wavelet Analysis , Principal Component Analysis
18.
IEEE Trans Biomed Circuits Syst ; 17(5): 968-984, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37695958

ABSTRACT

In this work, we present a hardware-software solution to improve the robustness of hand gesture recognition to confounding factors in myoelectric control. The solution includes a novel, full-circumference, flexible, 64-channel high-density electromyography (HD-EMG) sensor called EMaGer. The stretchable, wearable sensor adapts to different forearm sizes while maintaining uniform electrode density around the limb. Leveraging this uniformity, we propose novel array barrel-shifting data augmentation (ABSDA) approach used with a convolutional neural network (CNN), and an anti-aliased CNN (AA-CNN), that provides shift invariance around the limb for improved classification robustness to electrode movement, forearm orientation, and inter-session variability. Signals are sampled from a 4×16 HD-EMG array of electrodes at a frequency of 1 kHz and 16-bit resolution. Using data from 12 non-amputated participants, the approach is tested in response to sensor rotation, forearm rotation, and inter-session scenarios. The proposed ABSDA-CNN method improves inter-session accuracy by 25.67% on average across users for 6 gesture classes compared to conventional CNN classification. A comparison with other devices shows that this benefit is enabled by the unique design of the EMaGer array. The AA-CNN yields improvements of up to 63.05% accuracy over non-augmented methods when tested with electrode displacements ranging from -45 ° to +45 ° around the limb. Overall, this article demonstrates the benefits of co-designing sensor systems, processing methods, and inference algorithms to leverage synergistic and interdependent properties to solve state-of-the-art problems.


Subject(s)
Deep Learning , Wearable Electronic Devices , Humans , Electromyography , Gestures , Algorithms , Forearm/physiology
19.
IEEE Int Conf Rehabil Robot ; 2022: 1-5, 2022 07.
Article in English | MEDLINE | ID: mdl-36176075

ABSTRACT

Co-adaptive myoelectric human-machine systems are a fairly recent, but promising, advancement in pattern recognition-based myoelectric control. Their performance and stability, however, are not fully understood due in part to a lack of proper assessment tools. Time-series based analyses are typically used despite the availability of techniques used in other fields that can robustly measure stability and performance. In this research, we leverage the success achieved by lower limb systems to improve the assessment framework of co-adaptive myoelectric systems by exploiting a key feature common between the two systems. The cyclical dynamics found in lower limbs are also apparent in co-adaptive myoelectric systems, allowing us to analyze their behavior using Poincaré maps. A 10-day experiment was designed and conducted to observe the effects of algorithm adaptation and myoelectric experience level on the performance of a co-adaptive myoelectric control system. Through Poincaré maps, we were able to identify learning effects, as well as oscillations and uncertainty in performance. Assessment of these seemingly random variations in performance led to the inference that co-adaptive systems can be chaotic. Modelling co-adaptive myoelectric systems as cyclical leads to the application of an improved framework to better assess and describe their dynamics and performance.


Subject(s)
Adaptation, Physiological , Artificial Limbs , Electromyography/methods , Humans , Learning
20.
Article in English | MEDLINE | ID: mdl-35333717

ABSTRACT

Studies have shown that closed-loop myoelectric control schemes can lead to changes in user performance and behavior compared to open-loop systems. When users are placed within the control loop, such as during real-time use, they must correct for errors made by the controller and learn what behavior is necessary to produce desired outcomes. Augmented feedback, consequently, has been used to incorporate the user throughout the training process and to facilitate learning. This work explores the effect of visual feedback presented during user training on both the performance and predictability of a myoelectric classification-based control system. Our results suggest that properly designed feedback mechanisms and training tasks can influence the quality of the training data and the ability to predict usability using linear combinations of metrics derived from feature space. Furthermore, our results confirm that the most common in-lab training protocol, screen guided training, may yield training data that are less representative of online use than training protocols that incorporate the user in the loop. These results suggest that training protocols should be designed that better parallel the testing environment to more effectively prepare both the algorithms and users for real-time control.


Subject(s)
Biofeedback, Psychology , Feedback, Sensory , Algorithms , Electromyography/methods , Feedback , Humans