Neth Heart J ; 32(7-8): 283-289, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38865067

ABSTRACT

INTRODUCTION: When electrical storm (ES) is amenable to neither antiarrhythmic drugs, nor deep sedation or catheter ablation, autonomic modulation may be considered. We report our experience with percutaneous left stellate ganglion block (PSGB) to temporarily suppress refractory ventricular arrhythmia (VA) in patients with structural heart disease. METHODS: A retrospective analysis was performed at our institution of patients with structural heart disease and an implantable cardioverter defibrillator (ICD) who had undergone PSGB for refractory VA between January 2018 and October 2021. The number of times antitachycardia pacing (ATP) was delivered and the number of ICD shocks/external cardioversions performed in the week before and after PSGB were evaluated. Charts were checked for potential complications. RESULTS: Twelve patients were identified who underwent a combined total of 15 PSGB and 5 surgical left cardiac sympathetic denervation procedures. Mean age was 73 ± 5.8 years and all patients were male. Nine of 12 (75%) had ischaemic cardiomyopathy, with the remainder having non-ischaemic dilated cardiomyopathy. Mean left ventricular ejection fraction was 35% (±â€¯12.2%). Eight of 12 (66.7%) patients were already being treated with both amiodarone and beta-blockers. The reduction in ATP did not reach statistical significance (p = 0.066); however, ICD shocks (p = 0.028) and ATP/shocks combined were significantly reduced (p = 0.04). At our follow-up electrophysiology meetings PSGB was deemed ineffective in 4 of 12 patients (33%). Temporary anisocoria was seen in 2 of 12 (17%) patients, and temporary hypotension and hoarseness were reported in a single patient. DISCUSSION: In this limited series, PSGB showed promise as a method for temporarily stabilising refractory VA and ES in a cohort of male patients with structural heart disease. The side effects observed were mild and temporary.

2.
Eur Heart J ; 43(21): 2037-2050, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35090007

ABSTRACT

AIMS: To report 5-year outcomes of EFFORTLESS registry patients with early generation subcutaneous implantable cardioverter-defibrillator (S-ICD) devices. METHODS AND RESULTS: Kaplan-Meier, trend and multivariable analyses were performed for mortality and late (years 2-5) complications, appropriate shock (AS) and inappropriate shock (IAS) rates. Nine hundred and eighty-four of 994 enrolled patients with diverse diagnoses (28% female, 48 ± 17 years, body mass index 27 ± 6 kg/m2, ejection fraction 43 ± 18%) underwent S-ICD implantation. Median follow-up was 5.1 years (interquartile range 4.7-5.5 years). All-cause mortality was 9.3% (95% confidence interval 7.2-11.3%) at 5 years; 703 patients remained in follow-up on study completion, 171 withdrew including 87 (8.8%) with device explanted, and 65 (6.6%) lost to follow-up. Of the explants, only 20 (2.0%) patients needed a transvenous device for pacing indications. First and final shock efficacy for discrete ventricular arrhythmias was consistent at 90% and 98%, respectively, with storm episode final shock efficacy at 95.2%. Time to therapy remained unaltered. Overall 1- and 5-year complication rates were 8.9% and 15.2%, respectively. Early complications did not predict later complications. There were no structural lead failures. Inappropriate shock rates at 1 and 5 years were 8.7% and 16.9%, respectively. Self-terminating inappropriately sensed episodes predicted late IAS. Predictors of late AS included self-terminating appropriately sensed episodes and earlier AS. CONCLUSION: In this diverse S-ICD registry population, spontaneous shock efficacy was consistently high over 5 years. Very few patients underwent S-ICD replacement with a transvenous device for pacing indications. Treated and self-terminating arrhythmic episodes predict future shock events, which should encourage more personalized device optimization.


Subject(s)
Defibrillators, Implantable , Arrhythmias, Cardiac , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Female , Follow-Up Studies , Humans , Male , Stroke Volume , Treatment Outcome
3.
Europace ; 23(6): 887-897, 2021 06 07.
Article in English | MEDLINE | ID: mdl-33582797

ABSTRACT

AIMS: This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation. METHODS AND RESULTS: We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively. Between 2014 and 2018, we included 1441 consecutive patients in the development and 1450 patients in the validation cohort. During a median follow-up of 2.4 (IQR 2.1-2.8) years, 109 (7.6%) patients received appropriate ICD shock and 193 (13.4%) died in the development cohort. During a median follow-up of 2.7 (IQR 2.0-3.4) years, 105 (7.2%) received appropriate ICD shock and 223 (15.4%) died in the validation cohort. Selected predictors of appropriate ICD shock were gender, NSVT, ACE/ARB use, atrial fibrillation history, Aldosterone-antagonist use, Digoxin use, eGFR, (N)OAC use, and peripheral vascular disease. Selected predictors of all-cause mortality were age, diuretic use, sodium, NT-pro-BNP, and ACE/ARB use. C-statistic was 0.61 and 0.60 at respectively internal and external validation for appropriate ICD shock and 0.74 at both internal and external validation for mortality. CONCLUSION: Although this cohort study was specifically designed to develop prediction models, risk stratification still remains challenging and no large group with insufficient benefit of ICD implantation was found. However, the prediction models have some clinical utility as we present several scenarios where ICD implantation might be postponed.


Subject(s)
Defibrillators, Implantable , Angiotensin Receptor Antagonists , Angiotensin-Converting Enzyme Inhibitors , Cohort Studies , Death, Sudden, Cardiac/prevention & control , Humans , Primary Prevention , Risk Factors
4.
Pacing Clin Electrophysiol ; 43(10): 1173-1179, 2020 10.
Article in English | MEDLINE | ID: mdl-32901950

ABSTRACT

BACKGROUND: In the 123-study, we prospectively assessed, in a randomized fashion, the minimal cryoballoon application time necessary to achieve pulmonary vein (PV) isolation (PVI) in patients with paroxysmal atrial fibrillation (AF) with the aim to reduce complications by shortening the application duration. The first results of this study demonstrated that shortened cryoballoon applications (<2 minutes) resulted in less phrenic nerve injury (PNI) without compromising acute isolation efficacy for the right PVs. We now report the 1-year follow-up results regarding safety and efficacy of shorter cryoballoon applications. METHODS: A total of 222 patients with AF were randomized to two applications of 1 min "short," 2 min "medium," or 3 min "long" duration, 74 per group. Recurrence of AF and PV reconduction at 1-year follow-up were assessed. RESULTS: The overall 1-year freedom from AF was 79% and did not differ significantly between the short, medium, and long application groups (77%, 74%, and 85% for short, medium, and long application groups, respectively; P = 0.07). In 30 patients, a redo PVI procedure was performed. For all four PVs, there was no significant difference in reconduction between the three groups. Reconduction was most common in the left superior PV (57%). The right superior PV (RSPV) showed significantly less reconduction (17%) compared to the other PVs. CONCLUSIONS: Shortening cryoballoon applications of the RSPV to <2 minutes results in less PNI, while acute success and 1-year freedom from AF are not compromised. Therefore, shorter cryoballoon applications (especially) in the RSPV could be used to reduce PNI.


Subject(s)
Atrial Fibrillation/surgery , Cryosurgery/methods , Phrenic Nerve/injuries , Female , Humans , Male , Middle Aged , Prospective Studies , Recurrence , Time Factors
5.
J Card Fail ; 25(10): 812-818, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31479745

ABSTRACT

BACKGROUND: The beneficial effects of a cardiac resynchronization defibrillator (CRT-D) in patients with heart failure, low left ventricular ejection fraction (LVEF), and wide QRS have clearly been established. Nevertheless, mortality remains high in some patients. The aim of this study was to develop and validate a risk score to identify patients at high risk for early mortality who are implanted with a CRT-D. METHODS AND RESULTS: For predictive modelling, 1282 consecutive patients from 5 centers (74% male; median age 66 years; median LVEF 25%; New York Heart Association class III-IV 60%; median QRS-width 160 ms) were randomly divided into a derivation and validation cohort. The primary endpoint is mortality at 3 years. Model development was performed using multivariate logistic regression by checking log likelihood, Akaike information criterion, and Bayesian information criterion. Model performance was validated using C statistics and calibration plots. The risk score included 7 independent mortality predictors, including myocardial infarction, LVEF, QRS duration, chronic obstructive pulmonary disease, chronic kidney disease, hyponatremia, and anemia. Calibration-in-the-large was suboptimal, reflected by a lower observed mortality (44%) than predicted (50%). The validated C statistic was 0.71 indicating modest performance. CONCLUSION: A risk score based on routine, readily available clinical variables can assist in identifying patients at high risk for early mortality within 3 years after CRT-D implantation.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Risk Assessment/methods , Aged , Belgium/epidemiology , Cardiac Resynchronization Therapy/methods , Cardiac Resynchronization Therapy/statistics & numerical data , Defibrillators, Implantable/statistics & numerical data , Electric Countershock/statistics & numerical data , Female , Heart Failure/diagnosis , Heart Failure/mortality , Heart Failure/physiopathology , Heart Failure/therapy , Humans , Kaplan-Meier Estimate , Male , Mortality , Netherlands/epidemiology , Prognosis , Registries/statistics & numerical data , Risk Factors , Stroke Volume , Switzerland/epidemiology , Ventricular Function, Left
6.
Europace ; 21(9): 1360-1368, 2019 Sep 01.
Article in English | MEDLINE | ID: mdl-31168604

ABSTRACT

AIMS: The European REMOTE-CIED study is the first randomized trial primarily designed to evaluate the effect of remote patient monitoring (RPM) on patient-reported outcomes in the first 2 years after implantation of an implantable cardioverter-defibrillator (ICD). METHODS AND RESULTS: The sample consisted of 595 European heart failure patients implanted with an ICD compatible with the Boston Scientific LATITUDE® RPM system. Patients were randomized to RPM plus a yearly in-clinic ICD check-up vs. 3-6-month in-clinic check-ups alone. At five points during the 2-year follow-up, patients completed questionnaires including the Kansas City Cardiomyopathy Questionnaire and Florida Patient Acceptance Survey (FPAS) to assess their heart failure-specific health status and ICD acceptance, respectively. Information on clinical status was obtained from patients' medical records. Linear regression models were used to compare scores between groups over time. Intention-to-treat and per-protocol analyses showed no significant group differences in patients' health status and ICD acceptance (subscale) scores (all Ps > 0.05). Exploratory subgroup analyses indicated a temporary improvement in device acceptance (FPAS total score) at 6-month follow-up for secondary prophylactic in-clinic patients only (P < 0.001). No other significant subgroup differences were observed. CONCLUSION: Large clinical trials have indicated that RPM can safely and effectively replace most in-clinic check-ups of ICD patients. The REMOTE-CIED trial results show that patient-reported health status and ICD acceptance do not differ between patients on RPM and patients receiving in-clinic check-ups alone in the first 2 years after ICD implantation.ClinicalTrials.gov Identifier: NCT01691586.


Subject(s)
Ambulatory Care/methods , Blood Pressure Monitoring, Ambulatory , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Electrocardiography , Heart Failure/therapy , Patient Reported Outcome Measures , Quality of Life , Remote Sensing Technology/methods , Aftercare , Aged , Body Weight , Cardiology , Equipment Failure , Europe , Female , Heart Failure/physiopathology , Heart Failure/psychology , Humans , Linear Models , Male , Middle Aged , Primary Prevention , Secondary Prevention
7.
Europace ; 21(10): 1519-1526, 2019 Oct 01.
Article in English | MEDLINE | ID: mdl-31114860

ABSTRACT

AIMS: Idiopathic ventricular fibrillation (IVF) is a rare cause of sudden cardiac arrest. Implantable cardioverter-defibrillator (ICD) implantation is currently the only treatment option. Limited data are available on the prevalence and complications of ICD therapy in these patients. We sought to investigate ICD therapy and its complications in patients with IVF. METHODS AND RESULTS: Patients were selected from a national registry of IVF patients. Patients in whom no underlying diagnosis was found during follow-up were eligible for inclusion. Recurrence of ventricular arrhythmia (VA) was derived from medical and ICD records, electrogram records of ICD therapies were used to differentiate between appropriate or inappropriate interventions. Independent predictors for appropriate ICD shock were calculated using cox regression. In 217 IVF patients, recurrence of sustained VAs occurred in 66 patients (30%) during a median follow-up period of 6.1 years. Ten patients died (4.6%). Thirty-eight patients (17.5%) experienced inappropriate ICD therapy, and 32 patients (14.7%) had device-related complications. Symptoms before cardiac arrest [hazard ratio (HR): 2.51, 95% confidence interval (CI): 1.48-4.24], signs of conduction disease (HR: 2.27, 95% CI: 1.15-4.47), and carrier of the DPP6 risk haplotype (HR: 3.24, 1.70-6.17) were identified as independent predictors of appropriate shock occurrence. CONCLUSION: Implantable cardioverter-defibrillator therapy is an effective treatment in IVF, treating recurrences of potentially lethal VAs in approximately one-third of patients during long-term follow-up. However, device-related complications and inappropriate shocks were also frequent. We found significant predictors for appropriate ICD therapy. This may imply that these patients require additional management to prevent recurrent events.


Subject(s)
Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Electrocardiography , Tachycardia, Ventricular/therapy , Adult , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Female , Follow-Up Studies , Humans , Incidence , Male , Middle Aged , Netherlands/epidemiology , Tachycardia, Ventricular/mortality , Tachycardia, Ventricular/physiopathology , Treatment Outcome
8.
Pacing Clin Electrophysiol ; 42(12): 1541-1551, 2019 12.
Article in English | MEDLINE | ID: mdl-31677279

ABSTRACT

BACKGROUND: Use of the subcutaneous implantable defibrillator (S-ICD) has increased because the device received US Food and Drug Administration approval in 2012, but we still know little about whether the quality of life (QoL) of patients with an S-ICD versus a transvenous ICD (TV-ICD) is comparable. We compared S-ICD patients with TV-ICD patients on QoL, depression, and anxiety up to 12 months' follow-up. METHODS: A matched cohort of S-ICD (N = 167) and TV-ICD patients (N = 167) completed measures on QoL, depression, anxiety, and personality at baseline, 3, 6, and 12 months post implant. Data were analyzed using multivariable modeling with repeated measures. RESULTS: In adjusted analyses, we found no statistically significant differences between cohorts on physical and mental QoL and depression (all Ps > .05), while S-ICD patients reported lower anxiety than TV-ICD patients (P = 0.0007). Both cohorts experienced improvements in physical and mental QoL and symptoms of depression and anxiety over time (all Ps < .001), primarily between implant and 3 months. These improvements were similar for both cohorts with respect to physical and mental QoL and anxiety (Ps > .05), while S-ICD patients experienced greater reductions in depressive symptoms (P = .0317). CONCLUSION: The QoL and depression levels were similar in patients with an S-ICD and a TV-ICD up to 12 months' follow-up, while S-ICD patients reported lower anxiety levels and a greater reduction in depression over time as compared to TV-ICD patients. This knowledge may be important for patients and clinicians, if the indication for implantation allows both the S-ICD and the TV-ICD, making a choice possible.


Subject(s)
Anxiety/psychology , Defibrillators, Implantable/psychology , Depression/psychology , Quality of Life/psychology , Case-Control Studies , Equipment Design , Female , Humans , Male , Middle Aged , Surveys and Questionnaires
9.
Pacing Clin Electrophysiol ; 42(5): 508-514, 2019 05.
Article in English | MEDLINE | ID: mdl-30756393

ABSTRACT

BACKGROUND: The second-generation cryoballoon significantly improves outcome of pulmonary vein isolation (PVI) but may cause more complications than the first generation. Currently, no consensus regarding optimal cryoballoon application time exists. The 123-study aimed to assess the minimal cryoballoon application duration necessary to achieve PVI (primary endpoint) and the effect of application duration on prevention of phrenic nerve injury (PNI). METHODS: Patients <75 years of age with paroxysmal atrial fibrillation, normal PV anatomy, and left atrial size <40 cc/m² or <50 mm were randomized to two applications of different duration: "short," "medium," or "long." A total of 222 patients were enrolled, 74 per group. RESULTS: Duration per application was 105 (101-108), 164 (160-168), and 224 (219-226) s and isolation was achieved in 79, 89, and 90% (P < 0.001) of the PVs after two applications in groups short, medium, and long, respectively. Only for the left PVs, the success rate of the short group was significantly less compared to the medium- and long-duration groups (P < 0.001). PNI during the procedure occurred in 19 PVs (6.5%) in the medium and in 20 PVs (6.8%) in the long duration groups compared to only five PVs (1.7%) in the short duration group (P < 0.001). CONCLUSIONS: Short cryoballoon ablation application times, less than 2 min, did affect the success for the left PVs but not for the right PVs and resulted in less PNI. A PV tailored approach with shorter application times for the right PVs might be advocated.


Subject(s)
Atrial Fibrillation/surgery , Cryosurgery/methods , Phrenic Nerve/injuries , Pulmonary Veins/surgery , Female , Humans , Male , Middle Aged , Time Factors
10.
Europace ; 20(2): e1-e10, 2018 02 01.
Article in English | MEDLINE | ID: mdl-28339818

ABSTRACT

Aims: Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in systolic heart failure patients with ventricular conduction delay. Variability of individual response to CRT warrants improved patient selection. The Markers and Response to CRT (MARC) study was designed to investigate markers related to response to CRT. Methods and results: We prospectively studied the ability of 11 clinical, 11 electrocardiographic, 4 echocardiographic, and 16 blood biomarkers to predict CRT response in 240 patients. Response was measured by the reduction of indexed left ventricular end-systolic volume (LVESVi) at 6 months follow-up. Biomarkers were related to LVESVi change using log-linear regression on continuous scale. Covariates that were significant univariately were included in a multivariable model. The final model was utilized to compose a response score. Age was 67 ± 10 years, 63% were male, 46% had ischaemic aetiology, LV ejection fraction was 26 ± 8%, LVESVi was 75 ± 31 mL/m2, and QRS was 178 ± 23 ms. At 6 months LVESVi was reduced to 58 ± 31 mL/m2 (relative reduction of 22 ± 24%), 130 patients (61%) showed ≥ 15% LVESVi reduction. In univariate analysis 17 parameters were significantly associated with LVESVi change. In the final model age, QRSAREA (using vectorcardiography) and two echocardiographic markers (interventricular mechanical delay and apical rocking) remained significantly associated with the amount of reverse ventricular remodelling. This CAVIAR (CRT-Age-Vectorcardiographic QRSAREA -Interventricular Mechanical delay-Apical Rocking) response score also predicted clinical outcome assessed by heart failure hospitalizations and all-cause mortality. Conclusions: The CAVIAR response score predicts the amount of reverse remodelling after CRT and may be used to improve patient selection. Clinical Trials: NCT01519908.

11.
Europace ; 18(7): 1010-5, 2016 Jul.
Article in English | MEDLINE | ID: mdl-26324840

ABSTRACT

AIMS: The subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced to overcome complications related to transvenous leads. Adoption of the S-ICD requires implanters to learn a new implantation technique. The aim of this study was to assess the learning curve for S-ICD implanters with respect to implant-related complications, procedure time, and inappropriate shocks (IASs). METHODS AND RESULTS: In a pooled cohort from two clinical S-ICD databases, the IDE Trial and the EFFORTLESS Registry, complications, IASs at 180 days follow-up and implant procedure duration were assessed. Patients were grouped in quartiles based on experience of the implanter and Kaplan-Meier estimates of complication and IAS rates were calculated. A total of 882 patients implanted in 61 centres by 107 implanters with a median of 4 implants (IQR 1,8) were analysed. There were a total of 59 patients with complications and 48 patients with IAS. The complication rate decreased significantly from 9.8% in Quartile 1 (least experience) to 5.4% in Quartile 4 (most experience) (P = 0.02) and non-significantly for IAS from 7.9 to 4.8% (P = 0.10). Multivariable analysis demonstrated a hazard ratio of 0.78 (P = 0.045) for complications and 1.01 (P = 0.958) for IAS. Dual-zone programming increased with experience of the individual implanter (P < 0.001), which reduced IAS significantly in the multivariable model (HR 0.44, P = 0.01). Procedure time decreased from 75 to 65 min (P < 0.001). The complication rate and procedure time stabilized after Quartile 2 (>13 implants). CONCLUSION: There is a short and significant learning curve associated with physicians adopting the S-ICD. Performance stabilizes after 13 implants.


Subject(s)
Cardiac Surgical Procedures/education , Defibrillators, Implantable , Electric Countershock , Learning Curve , Prosthesis Implantation/education , Adult , Aged , Databases, Factual , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Multivariate Analysis , Proportional Hazards Models , Registries , Risk Factors , Treatment Outcome
12.
Europace ; 17(5): 747-52, 2015 May.
Article in English | MEDLINE | ID: mdl-25600767

ABSTRACT

AIMS: Transcatheter pulmonary vein ablation is the current treatment of choice for symptomatic drug-refractory atrial fibrillation (AF). Video-assisted surgical pulmonary vein isolation (sPVI) is an alternative therapy to percutaneous ablation for the treatment of AF. Long-term results of sPVI are currently unknown. The aim of this study was to report on the long-term efficacy and safety of sPVI in patients with paroxysmal AF. METHODS AND RESULTS: The study design was observational and retrospective. From July 2005 to January 2011, 42 patients with drug-refractory paroxysmal AF underwent video-assisted sPVI in two different centres. Patients were eligible for sPVI when suffering from symptomatic, drug-refractory paroxysmal AF and they agreed to the alternative of sPVI. The median preoperative AF duration was 24 months (range 3-200). Success was defined as the absence of AF on 24 h or 96 h Holter monitoring during follow-up, off antiarrhythmic drugs (AAD). Adverse events and follow-up monitoring were based on the Heart Rhythm Society Consensus Statement 2012 for the catheter and surgical ablation of AF. Mean age was 55 ± 10 years, and 76% were males. After a mean follow-up of 5 years (SD 1.7), 69% of all patients were free from atrial arrhythmias without the use of AAD, and 83% with the use of AAD. Major peri-procedural adverse events occurred in four (9.5%) patients, no strokes or mortalities were registered during long-term follow-up. CONCLUSION: This retrospective study shows that sPVI for the treatment of paroxysmal AF is effective and that the outcomes are maintained at long-term follow-up.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Pulmonary Veins/surgery , Thoracic Surgery, Video-Assisted/methods , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Electrocardiography, Ambulatory , Female , Humans , Male , Middle Aged , Pulmonary Veins/physiopathology , Remission Induction , Retrospective Studies , Thoracic Surgery, Video-Assisted/adverse effects , Time Factors , Treatment Outcome
13.
Europace ; 16(1): 88-91, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23913594

ABSTRACT

AIMS: The 5 French Sorin Hepta 4B lead is a bipolar transvenous pacemaker lead with a passive fixation mechanism. From 2003 to 2008, a total of 98 Sorin Hepta 4B right ventricular pacemaker leads were implanted in our hospital. We observed an unexpected high failure rate of this pacemaker lead. The aim of this study is to determine the performance of the Hepta 4B lead. METHODS AND RESULTS: A retrospective single-centre survey was conducted on the performance of all implanted Hepta 4B leads in our high-volume tertiary hospital. Information on all implants was stored in a database. Analysis of this database and patients' charts was performed to assess the rate of complications of all implanted Hepta 4B leads. Median time of follow-up was 5.49 (4.15-6.44) years. Of the 98 implanted Hepta 4B leads, 21 (21%) were replaced. A total of 18 (18%) leads showed electrical malfunction, leading to symptoms in five (5%) patients. Electrical malfunction included impedance change, threshold rise, and sensing problems. CONCLUSION: In this single-centre retrospective observation we report an extreme and unexpected failure rate of the Sorin Hepta lead. The most common complication was electrical dysfunction. The reason for this phenomenon has to be analysed, but the co-radial multifilar design, allowing a smaller diameter of the lead, may explain this finding.


Subject(s)
Electrodes, Implanted/statistics & numerical data , Equipment Failure Analysis/statistics & numerical data , Equipment Failure/statistics & numerical data , Pacemaker, Artificial/statistics & numerical data , Aged , Electric Conductivity , Female , Follow-Up Studies , Humans , Male , Netherlands , Retrospective Studies
14.
Europace ; 16(1): 40-6, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23918791

ABSTRACT

AIMS: To reduce sudden cardiac death, implantable cardioverter-defibrillators (ICDs) are indicated in patients with ischaemic and non-ischaemic dilated cardiomyopathy and a left ventricular ejection fraction (LVEF) ≤35%. Current guidelines do not recommend device therapy in patients with a life expectancy <1 year since benefit in these patients is low. In this study, we evaluated the incidence and predictors of early mortality (<1 year after implantation) in a consecutive primary prevention population. METHODS AND RESULTS: Analysis was performed on a prediction and validation cohort. The primary endpoint was all-cause mortality at 1 year. The prediction cohort comprised 861 prophylactic ICD recipients with ischaemic cardiomyopathy or dilated cardiomyopathy from the Academic Medical Center (Amsterdam) and Thorax Center Twente (Enschede). Detailed clinical data were collected. After multivariate analysis, a risk score was developed based on age ≥75 years, LVEF ≤ 20%, history of atrial fibrillation, and estimated glomerular filtration rate (eGFR) ≤30 mL/min/1.73 m(2). Using these predictors, a low (≤1 factor), intermediate (2 factors), and high (≥3 factors) risk group could be identified with 1-year mortality of, respectively, 3.4, 10.9, and 38.9% (P< 0.01). Afterwards, the risk score was validated in 706 primary prevention patients from the Erasmus Medical Center (Rotterdam). One-year mortality was, respectively, 2.5, 13.2, and 46.3% (all P< 0.01). CONCLUSION: A simple risk score based on age, LVEF, eGFR, and atrial fibrillation can identify patients at low, intermediate, and high risk for early mortality after ICD implantation. This may be helpful in the risk assessment of ICD candidates.


Subject(s)
Cardiomyopathies/mortality , Cardiomyopathies/prevention & control , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/statistics & numerical data , Risk Assessment/standards , Age Distribution , Aged , Aged, 80 and over , Female , Humans , Incidence , Male , Middle Aged , Netherlands/epidemiology , Prognosis , Reproducibility of Results , Risk Assessment/methods , Sensitivity and Specificity , Sex Distribution , Survival Analysis , Treatment Outcome
15.
Pacing Clin Electrophysiol ; 37(6): 768-73, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24456312

ABSTRACT

BACKGROUND: A phantom shock-the sensation of an implantable cardioverter defibrillator (ICD) discharge in the absence of an actual discharge-is a phenomenon that can occur in ICD patients. Little is known about the influence of psychological factors on the incidence of phantom shocks. We evaluated psychological correlates of phantom shocks 2 years post-ICD implant in a cohort of Dutch ICD recipients. METHODS: Consecutive patients (N = 300; 87.5% men; mean age = 62.3) willing to participate in a prospective study (Twente ICD Cohort Study) on psychological factors in ICD recipients received an ICD between September 2007 and February 2010. At baseline, patients complete the 36-item Short Form Health Survey, Hospital Anxiety and Depression Scale, and the Type D Scale. Lifetime presence of anxiety and depression was assessed with the MINI structural interview. RESULTS: During a follow-up of 24 months, 16 patients (5.4%) experienced a phantom shock. Median time to (first) phantom shock was 13 weeks (range 0-48 weeks). In univariable analysis, no significant relationships were found between clinical or psychological indices and the occurrence of phantom shocks, nor was there an association between phantom shocks and type D personality, symptoms of anxiety, or a history of anxiety and depression. CONCLUSIONS: Neither symptoms of anxiety and depression nor psychiatric history were associated with the occurrence of phantom shocks. Further studies using more explorative, qualitative research techniques are warranted to examine the correlates of phantom shocks.


Subject(s)
Anxiety/psychology , Defibrillators, Implantable/psychology , Depression/psychology , Electric Injuries/epidemiology , Electric Injuries/psychology , Psychophysiologic Disorders/epidemiology , Psychophysiologic Disorders/psychology , Anxiety/epidemiology , Causality , Comorbidity , Defibrillators, Implantable/statistics & numerical data , Depression/epidemiology , Equipment Failure Analysis/methods , Female , Humans , Incidence , Male , Netherlands/epidemiology , Prognosis , Psychometrics/methods , Psychometrics/statistics & numerical data , Reproducibility of Results , Risk Assessment , Sensitivity and Specificity , Treatment Outcome
16.
Pacing Clin Electrophysiol ; 37(7): 843-52, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24697703

ABSTRACT

BACKGROUND: Gender differences in patient-reported outcomes in patients with an implantable cardioverter defibrillator (ICD) have been researched, but findings are inconclusive and mostly based on cross-sectional study designs. To gain a better insight into potential determinants of psychological distress and health-related quality of life (HQOL), we examined the relationship between gender and patient-reported outcomes in patients with an ICD in the first year after ICD implantation. METHODS: Consecutive patients (N = 300) receiving an ICD between September 2007 and February 2010 at Medisch Spectrum Twente hospital, the Netherlands, completed several questionnaires to assess psychological distress and HQOL prior to ICD implantation and at 2 months, 5 months, 8 months, and 12 months postimplantation. RESULTS: Correcting for clinical confounders (e.g., left ventricular ejection fraction, ICD indication, comorbidities, ICD shocks), women reported higher levels of anxiety (P = 0.021) and shock-related anxiety (P = 0.047) than men in the course of a year. On most HQOL subscales, no gender differences were found, except for subscale Physical functioning, where women reported higher levels of improvement compared to men (P = 0.008). Gender was independently associated with poorer device-related acceptance, but only on the Florida Patient Acceptance Scale domain Body image concerns (P = 0.043), with women expressing higher levels of concerns about their body image compared to men. CONCLUSIONS: Women report higher levels of general and shock-related anxiety, and higher levels of body image concerns than men. Women showed more improvement in physical functioning. Screening patients before and after ICD implantation for general and shock anxiety may help determine patients who could benefit from psychological counseling.


Subject(s)
Anxiety/etiology , Defibrillators, Implantable/psychology , Depression/etiology , Quality of Life , Stress, Psychological/etiology , Anxiety/epidemiology , Depression/epidemiology , Female , Humans , Male , Middle Aged , Prospective Studies , Sex Factors , Stress, Psychological/epidemiology
17.
J Am Heart Assoc ; 13(8): e032033, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38591264

ABSTRACT

BACKGROUND: Chronic total coronary occlusions (CTO) substantially increase the risk for sudden cardiac death. Among patients with chronic ischemic heart disease at risk for sudden cardiac death, an implantable cardioverter defibrillator (ICD) is the favored therapy for primary prevention of sudden cardiac death. This study sought to investigate the impact of CTOs on the risk for appropriate ICD shocks and mortality within a nationwide prospective cohort. METHODS AND RESULTS: This is a subanalysis of the nationwide Dutch-Outcome in ICD Therapy (DO-IT) registry of primary prevention ICD recipients in The Netherlands between September 2014 and June 2016 (n=1442). We identified patients with chronic ischemic heart disease (n=663) and assessed available coronary angiograms for CTO presence (n=415). Patients with revascularized CTOs were excluded (n=79). The primary end point was the composite of all-cause mortality and appropriate ICD shocks. Clinical follow-up was conducted for at least 2 years. A total of 336 patients were included, with an average age of 67±9 years, and 20.5% was female (n=69). An unrevascularized CTO was identified in 110 patients (32.7%). During a median follow-up period of 27 months (interquartile range, 24-32), the primary end point occurred in 21.1% of patients with CTO (n=23) compared with 11.9% in patients without CTO (n=27; P=0.034). Corrected for baseline characteristics including left ventricular ejection fraction, and the presence of a CTO was an independent predictor for the primary end point (hazard ratio, 1.82 [95% CI, 1.03-3.22]; P=0.038). CONCLUSIONS: Within this nationwide prospective registry of primary prevention ICD recipients, the presence of an unrevascularized CTO was an independent predictor for the composite outcome of all-cause mortality and appropriate ICD shocks.


Subject(s)
Coronary Occlusion , Defibrillators, Implantable , Humans , Female , Middle Aged , Aged , Coronary Occlusion/complications , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/therapy , Arrhythmias, Cardiac , Defibrillators, Implantable/adverse effects , Stroke Volume , Incidence , Ventricular Function, Left , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Registries , Risk Factors
18.
Ann Noninvasive Electrocardiol ; 18(6): 564-70, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24303971

ABSTRACT

BACKGROUND: Although atrial fibrillation (AF) is the most commonly encountered arrhythmia, some of the properties make its detection challenging. In daily practice, underdiagnosis can lead to less effective treatment in prevention of stroke. Based on data from studies on treatment of AF, more intensive follow-up strategies, including 7-day Holter recording, 30-day event recording, and even implantable cardiac monitoring devices, are suggested. The study purpose is to evaluate the performance of a continuous single-channel loop recorder with automatic AF detection and transtelephonic electrocardiogram (ECG) transmission capabilities. METHODS AND RESULTS: A consecutive cohort of 153 patients admitted to the stroke unit with a presumptive diagnosis of ischemic cerebrovascular accident was screened for AF. Twenty-four-hour rhythm observation was performed using a single-channel external loop recorder (ELR) configured for automated AF detection. A total of 45 patients with a known history of AF, AF on the admission ECG, or incomplete registrations were excluded. Extensive additional frequency-based settings were used to establish a reference registration. In total, 2923 recordings were transmitted. We evaluated all events, of which 1190 were designated by the device as AF. The sensitivity, specificity, PPV, and NPV for identifying AF using the ELR were, respectively, 93%, 51%, 5%, and 99%. CONCLUSIONS: In this ELR validation study, the dedicated AF detection algorithm showed to be highly sensitive but not specific for AF. Applicability of an ELR might be limited for efficacious detection of AF, as manual verification is mandatory for a vast amount of recordings.


Subject(s)
Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Electrocardiography, Ambulatory/instrumentation , Electrocardiography, Ambulatory/methods , Telemetry/methods , Aged , Electrocardiography, Ambulatory/statistics & numerical data , Female , Humans , Male , Reproducibility of Results
19.
Int J Behav Med ; 20(3): 425-33, 2013 Sep.
Article in English | MEDLINE | ID: mdl-22821676

ABSTRACT

BACKGROUND: Personality factors and psychiatric history may help explain individual differences in risk of psychological morbidity and poor health outcomes in patients with an implantable cardioverter defibrillator (ICD). PURPOSE: We examined associations between previous anxiety and depressive disorder, type D personality, anxiety or depressive symptoms, and health status in ICD patients prior to ICD implantation. METHOD: Patients (N = 278; 83 % men; mean age = 62.2 years ±11) receiving a first ICD from September 2007 through April 2010 at the Medisch Spectrum Twente, The Netherlands completed validated questionnaires before implantation assessing type D personality (14-item Type D Scale), anxiety and depressive symptoms (Hospital Anxiety and Depression Scale), and health status (36-item Short Form Health Survey). History of anxiety or depressive disorder was assessed with the Mini International Neuropsychiatric Interview structural interview. RESULTS: Previous anxiety or depressive disorder was prevalent in 8 and 19 % of patients, respectively. Type D personality was present in 21 %, depressive symptoms in 15 %, and anxiety in 24 %. In adjusted analyses, type D personality was a dominant correlate of previous depressive disorder (odds ratio (OR) 6.2, p < 0.001) and previous anxiety disorder (OR 3.9, p = 0.004). Type D personality (OR 4.0, p < 0.001), age (OR 1.03, p = 0.043), and gender (OR 2.5, p = 0.013) were associated with anxiety symptoms at baseline. Type D personality (OR 5.9. p < 0.001) was also associated with increased depressive symptoms at baseline. Heart failure and type D personality were related to poorer health status. CONCLUSION: In ICD patients, prior to ICD implantation, a previous anxiety or depressive disorder, type D personality, and anxiety and depressive symptoms were associated with poorer health status. Type D personality was also independently associated with increased anxiety and depression symptoms.


Subject(s)
Anxiety Disorders/psychology , Anxiety/psychology , Defibrillators, Implantable/psychology , Depression/psychology , Depressive Disorder/psychology , Type D Personality , Aged , Anxiety/epidemiology , Anxiety Disorders/epidemiology , Coronary Disease/psychology , Coronary Disease/therapy , Depression/epidemiology , Depressive Disorder/epidemiology , Female , Health Status , Heart Failure/epidemiology , Heart Failure/psychology , Humans , Male , Middle Aged , Morbidity , Netherlands/epidemiology , Odds Ratio , Prevalence , Psychiatric Status Rating Scales , Risk Factors , Surveys and Questionnaires
20.
JACC Clin Electrophysiol ; 9(3): 345-355, 2023 03.
Article in English | MEDLINE | ID: mdl-36752476

ABSTRACT

BACKGROUND: Idiopathic ventricular fibrillation (iVF) is a diagnosis of exclusion. Systematic diagnostic testing is important to exclude alternative causes for VF. The early use of "high yield" testing, including cardiac magnetic resonance (CMR), exercise testing, and sodium channel blocker provocation, has been increasingly recognized. OBJECTIVES: The purpose of this study was to investigate the importance and consistency of systematic diagnostic testing in iVF. METHODS: This study included 423 iVF patients from 11 large secondary and tertiary hospitals in the Netherlands. Clinical characteristics and diagnostic testing data were ascertained. RESULTS: IVF patients experienced the index event at a median age of 40 years (IQR: 28-52 years), and 61% were men. The median follow-up time was 6 years (IQR: 2-12 years). Over the years, "high yield" diagnostic tests were increasingly performed (mean 68% in 2000-2010 vs 75% in 2011-2021; P < 0.001). During follow-up, 38 patients (9%) originally labeled as iVF received an alternative diagnosis. Patients in whom "high-yield" diagnostic tests were consistently performed during the initial work-up received an alternative diagnosis less frequently during follow-up (HR: 0.439; 95% CI: 0.219-0.878; P = 0.020). Patients who received an alternative diagnosis during follow-up had a worse prognosis in terms of cardiac death (P = 0.012) with a trend toward more implantable cardioverter-defibrillator therapy (P = 0.055). CONCLUSIONS: Although adherence to (near) complete diagnostic testing in this population of iVF patients increased over the years, patients with iVF still undergo varying levels of diagnostic evaluation. The latter leads to initial underdiagnosis of alternative conditions and is associated with a worse prognosis. Our results underscore the importance of early systematic diagnostic assessment in patients with apparent iVF.


Subject(s)
Electrocardiography , Neoplasm Recurrence, Local , Male , Humans , Adult , Middle Aged , Female , Registries , Fertilization in Vitro