Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Clin Chem Lab Med ; 56(7): 1054-1062, 2018 06 27.
Article in English | MEDLINE | ID: mdl-29425105

ABSTRACT

BACKGROUND: Longer pre-centrifugation times alter the quality of serum and plasma samples. Markers for such delays in sample processing and hence for the sample quality, have been identified. METHODS: Twenty cytokines in serum, EDTA plasma and citrate plasma samples were screened for changes in concentration induced by extended blood pre-centrifugation delays at room temperature. The two cytokines that showed the largest changes were further validated for their "diagnostic performance" in identifying serum or plasma samples with extended pre-centrifugation times. RESULTS: In this study, using R&D Systems ELISA kits, EDTA plasma samples and serum samples with a pre-centrifugation delay longer than 24 h had an IL16 concentration higher than 313 pg/mL, and an IL8 concentration higher than 125 pg/mL, respectively. EDTA plasma samples with a pre-centrifugation delay longer than 48 h had an IL16 concentration higher than 897 pg/mL, citrate plasma samples had an IL8 concentration higher than 21.5 pg/mL and serum samples had an IL8 concentration higher than 528 pg/mL. CONCLUSIONS: These robust and accurate tools, based on simple and commercially available ELISA assays can greatly facilitate qualification of serum and plasma legacy collections with undocumented pre-analytics.


Subject(s)
Interleukin-16/blood , Interleukin-8/blood , Adult , Arthritis, Rheumatoid/blood , Biomarkers/blood , Blood Chemical Analysis/methods , Centrifugation , Cohort Studies , Enzyme-Linked Immunosorbent Assay , Female , Humans , Male , Middle Aged , Pancreatitis/blood , ROC Curve , Specimen Handling , Temperature , Time Factors , Young Adult
2.
J Immunol Methods ; 465: 13-19, 2019 02.
Article in English | MEDLINE | ID: mdl-30496732

ABSTRACT

BACKGROUND: Uncontrolled preanalytical variables can reduce the accuracy and reproducibility of downstream analytical results from peripheral blood mononuclear cells (PBMCs). METHODS: PBMCs were isolated from EDTA and citrate-anticoagulated blood samples, obtained from healthy subjects and patients with inflammatory and infectious conditions. PBMC-derived RNA samples were examined for gene expression changes induced by extended blood pre-centrifugation delays at 4 °C and RT. We used Taqman RTqPCR to evaluate the combination of two target genes for their "diagnostic performance" in identifying EDTA and citrate-anticoagulated PBMC samples with extended pre-centrifugation times. RESULTS: We established the PBMC preanalytical score, a gene expression metric to asses the PBMC quality related to the pre-centrifugation delay at room temperature for different anticoagulants. The PBMC preanalytical score measurement can identify: CONCLUSION: The proposed PBMC preanalytical score may enable objective PBMC sample qualification for downstream applications, which may be influenced by blood precentrifugation delays.


Subject(s)
Calcium-Binding Proteins/biosynthesis , Gene Expression Regulation , Interleukin-8/biosynthesis , Leukocytes, Mononuclear/metabolism , alpha-Mannosidase/biosynthesis , Adult , Aged , Female , Humans , Leukocytes, Mononuclear/cytology , Male , Middle Aged
3.
Biopreserv Biobank ; 16(1): 16-22, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29394087

ABSTRACT

The College of American Pathologists (CAP) developed the Biorepository Accreditation Program (BAP) in 2012. This program integrates best practices from the International Society for Biological and Environmental Biorepositories, the National Cancer Institute, the Organisation for Economic Cooperation and Development, the Center for Medicare and Medicaid Services, and the CAP Laboratory Accreditation Program. The goal of this elective program is to provide requirements for standardization in biorepository processes that will result in high-quality specimens that can be used to support research, drug discovery, and personalized medicine. CAP uses a peer inspection model to ensure the inspectors have proper expertise and to promote educational efforts through information sharing. Lead inspectors are comprised of pathologists, PhDs, and managers of biorepositories and they are often supported by CAP staff inspectors. Accreditation is a 3-year continuous cycle of quality with a peer inspection occurring at the start of year 1 and a self-inspection and CAP desk assessment at the start of year 2 and 3. At this time 53 biorepositories are fully CAP BAP accredited and 13 are in the process of obtaining accreditation. There are currently 273 established standards with requirement lists customized based on the scope of activities performed by a biorepository. A total of 90 inspections were completed between May 2012 and December 2016. Sixty-one were initial inspections and 29 were reinspections. A total of 527 deficiencies were identified in the areas of Equipment/Instrumentation (22%), Information Technology (18%), Specimen Handling and QC (15%), Quality Management (16%), Personnel (11%), Safety (10%), Facilities (6%), and Regulatory (2%). Assessment of common deficiencies identifies areas of focus for continuous improvement and educational opportunities. Overall success of the program is high based on the current enrollment of 66 biorepositories, anecdotal participant feedback and increasing national recognition of the BAP in federal documents.


Subject(s)
Accreditation/standards , Biological Specimen Banks/organization & administration , Biological Specimen Banks/standards , Humans , Information Dissemination , Pathologists , Quality Control , Societies, Medical , United States
5.
Biopreserv Biobank ; 10(4): 366-74, 2012 Aug.
Article in English | MEDLINE | ID: mdl-24849886

ABSTRACT

The first version of the Standard PREanalytical Code (SPREC) was developed in 2009 by the International Society for Biological and Environmental Repositories (ISBER) Biospecimen Science Working Group to facilitate documentation and communication of the most important preanalytical quality parameters of different types of biospecimens used for research. This same Working Group has now updated the SPREC to version 2.0, presented here, so that it contains more options to allow for recent technological developments. Existing elements have been fine tuned. An interface to the Biospecimen Reporting for Improved Study Quality (BRISQ) has been defined, and informatics solutions for SPREC implementation have been developed. A glossary with SPREC-related definitions has also been added.


Subject(s)
Biological Specimen Banks/standards , Biological Specimen Banks/organization & administration , Quality Control , Specimen Handling/standards
6.
Cancer Epidemiol Biomarkers Prev ; 19(4): 1004-11, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20332280

ABSTRACT

BACKGROUND: Management and traceability of biospecimen preanalytical variations are necessary to provide effective and efficient interconnectivity and interoperability between Biobanks. METHODS: Therefore, the International Society for Biological and Environmental Repositories Biospecimen Science Working Group developed a "Standard PREanalytical Code" (SPREC) that identifies the main preanalytical factors of clinical fluid and solid biospecimens and their simple derivatives. RESULTS: The SPREC is easy to implement and can be integrated into Biobank quality management systems and databases. It can also be extended to nonhuman biorepository areas. Its flexibility allows integration of new novel technological developments in future versions. SPREC version 01 is presented in this article. CONCLUSIONS AND IMPACT: Implementation of the SPREC is expected to facilitate and consolidate international multicenter biomarker identification research and biospecimen research in the clinical Biobank environment.


Subject(s)
Biological Specimen Banks/standards , Specimen Handling/standards , Humans
SELECTION OF CITATIONS
SEARCH DETAIL