Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 110
Filter
Add more filters

Country/Region as subject
Affiliation country
Publication year range
1.
Circ J ; 2024 May 11.
Article in English | MEDLINE | ID: mdl-38735703

ABSTRACT

BACKGROUND: Based on the results of a clinical trial in Japan, transcatheter aortic valve replacement (TAVR) for hemodialysis (HD) patients gained approval; however, mid-term TAVR outcomes and transcatheter aortic valve (TAV) durability in HD patients remain unexplored.Methods and Results: We analyzed background, procedural, in-hospital outcome, and follow-up data for 101 HD patients and 494 non-HD patients who underwent TAVR using balloon-expandable valves (SAPIEN XT or SAPIEN 3) retrieved from Osaka University Hospital TAVR database. Periprocedural mortality and TAVR-related complications were comparable between HD and non-HD patients. However, Kaplan-Meier analysis revealed that HD patients had significantly lower survival rates (log-rank test, P<0.001). In addition, HD patients had significantly higher rates of severe structural valve deterioration (SVD) than non-HD patients (Gray test, P=0.038). CONCLUSIONS: TAVR in HD patients had comparable periprocedural mortality but inferior mid-term survival and TAV durability than in non-HD patients. Indications for TAVR in younger HD patients should be carefully determined, considering the possibility of a TAV-in-TAV procedure when early SVD occurs.

2.
J Artif Organs ; 2024 Mar 23.
Article in English | MEDLINE | ID: mdl-38520590

ABSTRACT

We report a case of temporary Berlin Heart EXCOR® explantation in a pediatric patient with idiopathic dilated cardiomyopathy who suffered an uncontrollable inflow cannulation site infection while on bridge-to-transplantation. Despite failure to thrive and catheter-related infections, once free of the device, the patient was cured of infection using systemic antibiotics and surgical debridement. The patient underwent EXCOR® reimplantation after four months, and is awaiting heart transplantation in stable condition. A life-threatening ventricular assist device-related infection may require device explantation under conditions that may not fulfill conventional explantation criteria despite risks. Temporary explantation can be an effective strategy if isolated systolic dysfunction is managed carefully.

3.
Surg Today ; 54(1): 73-79, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37490071

ABSTRACT

PURPOSE: Culture of extracted drains or epicardial pacing wires is an easy and noninvasive method for detecting mediastinitis after open-heart surgery, although studies on its sensitivity and specificity are limited. We, therefore, investigated the usefulness of this approach for diagnosing mediastinitis. METHODS: We retrospectively studied the culture results of drains and epicardial pacing wires extracted from 3308 patients. Prediction models of mediastinitis with and without culture results added to clinical risk factors identified by a logistic regression analysis were compared. RESULTS: The incidence of mediastinitis requiring surgery was 1.89% (n = 64). Staphylococcus was the causative bacterium in 64.0% of cases. The sensitivity, specificity, and positive and negative predictive values of positive culture results were 50.8%, 91.8%, 10.7%, and 99.0%, respectively. Methicillin-resistant Staphylococcus aureus had the highest positive predictive value (61.5%). A multivariate analysis identified preoperative hemodialysis (OR 5.40 [2.54-11.5], p < 0.01), long operative duration (p < 0.01), postoperative hemodialysis (OR 2.25 [1.01-4.98], p < 0.05), and positive culture result (OR 10.2 [5.88-17.7], p < 0.01) as independent risk factors. The addition of culture results to pre- and postoperative hemodialysis and a lengthy operative time improved the prediction of mediastinitis. CONCLUSIONS: A culture survey using extracted drains and epicardial pacing wires may provide useful information for diagnosing mediastinitis.


Subject(s)
Cardiac Surgical Procedures , Mediastinitis , Methicillin-Resistant Staphylococcus aureus , Humans , Retrospective Studies , Mediastinitis/diagnosis , Mediastinitis/etiology , Mediastinitis/therapy , Cardiac Surgical Procedures/adverse effects , Staphylococcus
4.
J Endovasc Ther ; : 15266028231206993, 2023 Oct 26.
Article in English | MEDLINE | ID: mdl-37882164

ABSTRACT

PURPOSE: The effectiveness of thoracic endovascular aortic repair (TEVAR) for chronic aortic dissection (AD) with aneurysmal degeneration remains controversial. We retrospectively investigated clinical outcomes and assessed predictors of aortic shrinkage after TEVAR for chronic aneurysmal AD. MATERIALS AND METHODS: Between January 2010 and December 2021, 70 patients with double-barrel-type chronic AD were enrolled. Major intimal tears in thoracic aorta were covered by stent graft. Early and late clinical outcomes, and diameter change of downstream aorta during follow-up period were reviewed. Subsequently, factors associated with aortic shrinkage were assessed by logistic regression analysis. RESULTS: Mean age was 63 (interquartile range [IQR]: 54-68) years, 54 (80%) men, median duration from AD onset was 4 (IQR: 1-10) years, and maximum aortic diameter was 53 (IQR: 49-58) mm. Supra-aortic debranching procedure was required in 57 (81%) patients. Early aorta-related death occurred in 2 (3%) patients. Both stroke and spinal cord ischemia occurred in 1 (2%) patient. Five-year freedom rates from aorta-related death and reintervention were 96% and 51%, respectively. Sixty-four patients underwent follow-up computed tomography (84%) 1 year after TEVAR, with 33 (52%) achieving aortic shrinkage. In multivariable analysis, duration from AD onset (per year) (odds ratio [OR]: 0.82, 0.70-0.97; p=0.017) and maximum aortic-diameter ratio between aortic arch and descending aorta (per 0.1) (morphologic index; OR: 1.34, 1.04-1.74; p=0.023) were independent aortic shrinkage predictors. CONCLUSIONS: Thoracic endovascular aortic repair for chronic AD with aneurysmal degeneration achieved satisfactory survival outcomes, but with a considerable reintervention rate. Duration from AD onset and preoperative aortic morphology could affect post-TEVAR aortic shrinkage. Earlier intervention could lead to better aortic shrinkage. CLINICAL IMPACT: Thoracic endovascular aortic repair for chronic aortic dissection with aneurysmal degeneration showed low incidence of early and late aorta-related death. By contrast, aortic shrinkage rate was low with high incidence of reintervention to the residual downstream aorta. According to the assessment of preoperative variables, chronicity and aortic morphology could predict postoperative aortic shrinkage.

5.
Eur J Vasc Endovasc Surg ; 66(4): 513-520, 2023 10.
Article in English | MEDLINE | ID: mdl-37330200

ABSTRACT

OBJECTIVE: This study aimed to investigate the impact of the number of patent lumbar arteries (LAs) on sac enlargement after endovascular aneurysm repair (EVAR). METHODS: This was a retrospective cohort single centre registry study. Between January 2006 and December 2019, 336 EVARs were reviewed using a commercially available device excluding type I or type III endoleaks during a follow up of ≥ 12 months. Patients were divided into four groups based on the pre-operative patency of the inferior mesenteric artery (IMA) and high (≥ 4) or low (≤ 3) number of patent LAs: Group 1, patent IMA and high number of patent LAs; Group 2, patent IMA and low number of patent LAs; Group 3, occluded IMA and a high number of patent LAs; Group 4, occluded IMA and low number of patent LAs. RESULTS: Groups 1, 2, 3, and 4 included 124, 104, 45, and 63 patients, respectively. The median follow up duration was 65.1 months. Significant differences in the incidence of overall type II endoleak (T2EL) at discharge between Group 1 and Group 2 (59.7% vs. 36.5%, p < .001) and between Group 3 and Group 4 (33.3% vs. 4.8%, p < .001) were observed. In patients with a pre-operatively patent IMA, the rate of freedom from aneurysm sac enlargement was significantly lower in Group 1 than in Group 2 (69.0% vs. 81.7% five years after EVAR, p < .001). In patients with a pre-operatively occluded IMA, the freedom rate from aneurysm sac enlargement was not significantly different between Groups 3 and Group 4 (95.0% vs. 100% five years after EVAR, p = .075). CONCLUSION: A high number of patent LAs seemed to have a significant role in sac enlargement with T2EL when the IMA was patent pre-operatively, whereas a high number of patent LAs seemed to have limited influence on sac enlargement when the IMA was occluded pre-operatively.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Embolization, Therapeutic , Endovascular Procedures , Humans , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/epidemiology , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Endovascular Aneurysm Repair , Retrospective Studies , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Aorta, Abdominal/surgery , Treatment Outcome , Embolization, Therapeutic/adverse effects , Risk Factors
6.
J Artif Organs ; 2023 Jul 19.
Article in English | MEDLINE | ID: mdl-37468735

ABSTRACT

During continuous-flow left ventricular assist device (CF-LVAD) support, hemodynamic shear stress causes a burden on aortic valve (AV) leaflets, leading to de novo aortic insufficiency (AI). This study investigated the influence of preoperative hemodynamic parameters on de novo AI in CF-LVAD recipients. We reviewed 125 patients who underwent CF-LVAD implantation without concomitant AV surgery between 2005 and 2018. De novo AI was defined as moderate or severe AI in those with none or trivial preoperative AI. During mean 30 ± 16 months of CF-LVAD support, de novo AI-free rate was 86% and 67% at 1 and 2 years, respectively. Multivariable analysis showed that higher right ventricular stroke work index (RVSWI) (hazard ratio, 1.12 /g/m2/beat; 95% confidence interval, 1.00-1.20; p = 0.047) and trivial grade AI (hazard ratio, 2.8; 95% confidence interval, 1.2-6.4; p = 0.020) were independent preoperative risk factors for de novo AI. The longitudinal analysis using generalized mixed effects model showed that higher RVSWI was associated with continuous AV closure after LVAD implantation (Odd ratio, 1.20/g/m2/beat; 95% confidence interval, 1.00-1.43 /g/m2/beat; p = 0.047). Right heart catheterization revealed that preoperative RVSWI was positively correlated with postoperative pump flow index in patients with continuously closed AV (r = 0.44, p = 0.04, n = 22). Preoperative higher RVSWI was a significant risk factor for de novo AI following CF-LVAD implantation. In patients with preserved right ventricular function, postoperative higher pump flow may affect AI development via hemodynamic stress on the AV.

7.
J Endovasc Ther ; 29(3): 427-437, 2022 06.
Article in English | MEDLINE | ID: mdl-34802327

ABSTRACT

PURPOSE: Zone 0 landing in thoracic endovascular aortic repair (TEVAR) has recently gained increasing attention for the treatment of high-risk patients. The aim of this study was to compare the outcomes of total endovascular aortic arch repair between branched TEVAR (bTEVAR) and chimney TEVAR (cTEVAR) in the landing zone (LZ) 0. MATERIALS AND METHODS: This was a single-center, retrospective, and observational cohort study. From January 2010 to March 2020, 40 patients (bTEVAR, n=25; cTEVAR, n=15; median age: 79 years) were enrolled in this study, with a median follow-up period of 4.1 years. These patients were considered unsuitable for open surgical treatment. RESULTS: All procedures were successful and no cases of conversion to open repair were noted during the 30-day postoperative period. The 30-day mortality was 2.5% (n=1; bTEVAR [0 of 25, 0%] vs cTEVAR [1 of 15, 6.7%]; p=0.375), the perioperative stroke rate was 10.0% (n=4; bTEVAR [4 of 25, 16.0%] vs cTEVAR [0 of 15, 0%], p=0.278), and type 1a endoleak rate was 15.0% (n=6; bTEVAR [0 of 25, 0%] vs cTEVAR [6 of 15, 40.0%], p=0.001). The risk factor for stroke was atheroma grade of ≥2 in the brachiocephalic artery (p<0.001). The risk factor for type 1a endoleak was cTEVAR (p=0.001). The 8-year survival rate was 49.9%. The aorta-related death-free rate and aortic event-free rate at 8 years were 94.4% (bTEVAR: 95.5% vs cTEVAR: 93.3%, p=0.504) and 60.7% (bTEVAR: 70.7% vs cTEVAR: 40.0%, p=0.048), respectively. CONCLUSIONS: Total endovascular aortic arch repair using bTEVAR and cTEVAR is feasible for the treatment of aortic arch diseases in high-risk patients who are unsuitable for open surgery. However, as the rate of stroke is high, strict preoperative evaluation to prevent stroke is needed. No rupture of the aneurysm was observed in cTEVAR, but patients should be selected carefully because of the high incidence of type 1a endoleak.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Diseases , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Stroke , Aged , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/complications , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Diseases/surgery , Blood Vessel Prosthesis/adverse effects , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Humans , Retrospective Studies , Risk Factors , Stroke/etiology , Time Factors , Treatment Outcome
8.
J Endovasc Ther ; : 15266028221121748, 2022 Sep 17.
Article in English | MEDLINE | ID: mdl-36120997

ABSTRACT

PURPOSE: The impact of preoperative patent inferior mesenteric artery (IMA) on late outcomes following endovascular aneurysm repair (EVAR) remains unclear. This study aimed to investigate the specific influence of IMA patency on 7-year outcomes after EVAR. MATERIALS AND METHODS: In this retrospective cohort study, 556 EVARs performed for true abdominal aortic aneurysm cases between January 2006 and December 2019 at our institution were reviewed. Endovascular aneurysm repairs performed using a commercially available device with no type I or type III endoleak (EL) during follow-up and with follow-up ≥12 months were included. A total of 336 patients were enrolled in this study. The cohort was divided into the patent IMA group and the occluded IMA group according to preoperative IMA status. The late outcomes, including aneurysm sac enlargement, reintervention, and mortality rates, were compared between both groups using propensity-score-matched data. RESULTS: After propensity score matching, 86 patients were included in each group. The median follow-up period was 56 months (interquartile range: 32-94 months). The incidence of type II EL at discharge was 50% in the patent IMA group and 19% in the occluded IMA group (p<0.001). The type II EL from IMA and lumbar arteries was significantly higher in the patent IMA group than in the occluded IMA group (p<0.001 and p=0.002). The rate of freedom from aneurysm sac enlargement with type II EL was significantly higher in the occluded IMA group than in the patent IMA group (94% vs 69% at 7 years; p<0.001). The rate of freedom from reintervention was significantly higher in the occluded IMA group than in the patent IMA group (90% vs 74% at 7 years; p=0.007). Abdominal aortic aneurysm-related death and all-cause mortality did not significantly differ between groups (p=0.32 and p=0.34). CONCLUSIONS: Inferior mesenteric artery patency could affect late reintervention and aneurysm sac enlargement but did not have a significant impact on mortality. Preoperative assessment and embolization of IMA might be an important factor for improvement in late EVAR outcomes. CLINICAL IMPACT: The preoperative patency of the inferior mesenteric artery was significantly associated with a higher incidence of sac enlargement and reintervention with type II endoleak following endovascular aneurysm repair, even after adjustment for patient background. Preoperative assessment and embolization of inferior mesenteric artery might be an important factor for improvement in late EVAR outcomes.

9.
Eur J Vasc Endovasc Surg ; 63(3): 410-420, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34916108

ABSTRACT

OBJECTIVE: Hybrid thoracic endovascular aortic repair (TEVAR) is being accepted increasingly as a first line treatment for arch repair at the present authors' institution. This study aimed to clarify the effectiveness of zones 0, 1, and 2 landing hybrid TEVAR. METHODS: This was a retrospective single centre case series. From April 2008 to March 2020, 348 patients (median age 72 years; interquartile range [IQR] 65, 77 years) were enrolled, with a median follow up period of 5.6 years (IQR 2.6, 8.7 years). The procedures included zone 0 in 135 patients (38.8%), zone 1 in 82 patients (23.6%), and zone 2 proximal landing zone (LZ) hybrid TEVAR in 131 patients (37.6%). The pathologies consisted of dissecting aortic aneurysms in 123 (35.3%) patients. Emergency procedures were performed in 39 (11.2%) patients. RESULTS: The 30 day mortality (n = 2, 0.6%) and hospital deaths (n = 6, 1.7%) were registered. The stroke rate was 1.1% (n = 4), while early and late endoleak rates were 4.8% (n = 17) and 1.7% (n = 6), respectively. Type 1a endoleak and retrograde type A dissection occurred in seven (2.0%) and three (0.9%) patients, respectively. The cumulative survival, freedom from aorta related deaths, and freedom from aortic events in 10 years were 75.0%, 97.2%, and 84.1%, respectively. The freedom from aortic events in each landing zone in 10 years was 82.3%, 81.4%, and 87.9% for zones 0, 1, and 2, respectively. The 10 year survival rates were 82.5% and 73.6%; the 10 year aorta related death free rates were 94.9% and 98.6%, and the 10 year aortic event free rates were 82.3% and 85.5% in the zone 0 and zone 1 and 2 TEVAR, respectively. CONCLUSION: Satisfactory early and long term results of hybrid arch repair at zones 0, 1, and 2 were achieved. To avoid complications and aortic events, the treatment strategy of hybrid arch repair for aortic arch pathologies should be tailored using accurate pre-operative assessment of the ascending aorta and the aortic arch.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Humans , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
10.
Circ J ; 86(11): 1764-1768, 2022 10 25.
Article in English | MEDLINE | ID: mdl-36184556

ABSTRACT

BACKGROUND: The use of hybrid operating rooms (HOR) for transcatheter aortic valve implantation (TAVI) has increased, so radiation exposure during procedures that use X-ray fluoroscopy is a fundamental problem not only for patients but also for surgeons and interventional cardiologists, increasing the risk of cataracts among operators. We investigated the efficacy of leaded glasses and protective sheets for ocular radiation protection.Methods and Results: Between January 2020 and February 2021 we enrolled 54 TAVI procedures using the transfemoral approach. The subjects were divided into a curtain protection group (Group C, n=20), glass protection group (Group G, n=17), and sheet protection group (Group S, n=17). The cumulative dose (CD) of the operators showed a decreasing trend in Group S compared with the other two groups. The CD normalized by dose area product (CD/DAP) of the operators was significantly reduced in Group S compared with Group C. However, Group G showed no significant difference compared with Group C. Regarding the distribution of CD/DAP, Group S had a significantly lower distribution than that in groups C and G. CONCLUSIONS: Protective sheets provide more stable radiation protection than conventional curtains or leaded glasses.


Subject(s)
Aortic Valve Stenosis , Radiation Exposure , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Radiation Dosage , Risk Factors , Radiation Exposure/adverse effects , Radiation Exposure/prevention & control , Fluoroscopy/adverse effects , Aortic Valve/surgery , Treatment Outcome
11.
Circ J ; 2022 Dec 27.
Article in English | MEDLINE | ID: mdl-36575039

ABSTRACT

BACKGROUND: Limited data are available for clinical outcomes in patients who underwent urgent or emergency transcatheter aortic valve implantation (TAVI). This study investigated in-hospital and 1-year outcomes and explored prognostic covariates in urgent/emergency TAVI using nationwide registry data.Methods and Results: Among 26,775 patients who underwent TAVI between August 2013 and December 2019, 25,495 with 1-year follow-up information were analyzed in this study. Baseline and procedural characteristics, as well as clinical adverse events, were compared between the urgent/emergency and elective TAVI groups. The primary outcome was all-cause mortality within 1 year after TAVI. Multivariable Cox regression models were constructed to identify independent predictors after urgent or emergency TAVI. Urgent or emergency TAVI was performed in 578 (2.3%) patients. The Society of Thoracic Surgeons score was significantly higher in the urgent/emergency than elective TAVI group (13.3% vs. 6.0%; P<0.001). Device success rate was comparable between the 2 groups. All-cause death-free survival within 1 year was lower in the urgent/emergency than elective TAVI group (77.2% vs. 92.2%; log rank P<0.001). Malignancy, albumin and creatinine concentrations, ejection fraction, and mean pressure gradient were associated with 1-year mortality in the urgent/emergency TAVI group. CONCLUSIONS: Despite higher surgical risk and more comorbidities, the procedure was successfully performed in patients undergoing urgent/emergency TAVI, although it should be noted that prognosis was worse than for elective TAVI.

12.
J Artif Organs ; 2022 Nov 27.
Article in English | MEDLINE | ID: mdl-36436162

ABSTRACT

We describe a case in which an axillary Impella 5.0, stuck in an area of calcification in the right subclavian artery, could not be retrieved in the usual manner. However, it was successfully removed using a long 22-Fr sheath and snaring catheter by means of the trans-femoral artery. Device retrieval using the trans-femoral artery snare technique is considered a valid option for removing the Impella device in patients who exhibit this complication.

13.
Ren Fail ; 44(1): 1083-1089, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35796036

ABSTRACT

BACKGROUND: Patients undergoing maintenance hemodialysis (HD) with severe aortic stenosis are at a high risk for bioprosthetic valve dysfunction after transcatheter aortic valve implantation (TAVI). Currently, preoperative factors that predict the occurrence of valve dysfunction after TAVI on HD patients remain to be elucidated. The aim of this study is to analyze the association between preoperative clinical factors and valve stenosis after TAVI on HD patients. METHODS: Twenty-four of HD patients who underwent TAVI at our institution between April 2012 and January 2016 were analyzed. The mean aortic transvalvular pressure gradient (MPG) and effective orifice area index (EOAi) were assessed by serial echocardiography. Associations between preoperative clinical factors and time-series changes in MPG were examined using mixed-effects linear regression model for repeated measures. RESULTS: Three patients developed severe structural valve deterioration with calcific valve stenosis requiring reoperation. A multivariate linear mixed-effects model showed that lower serum magnesium (sMg) levels were associated with the increase of MPG after TAVI (beta-coefficient = 0.019, p = 0.03). No correlation was observed with serum calcium, phosphorus, or intact parathyroid hormone. Time-series changes of MPG and EOAi had significant difference between lower and higher sMg group. All 3 of the patients who underwent reoperation showed lower preoperative sMgs. CONCLUSION: Among bone-mineral metabolism markers, preoperative hypomagnesemia was associated with the increase of MPG after TAVI, suggesting that hypomagnesemia could predict post-TAVI valve dysfunction in HD patients. Further studies with larger sample sizes are warranted.


Subject(s)
Transcatheter Aortic Valve Replacement , Constriction, Pathologic , Humans , Magnesium , Postoperative Period , Renal Dialysis/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects
14.
Kyobu Geka ; 75(1): 15-20, 2022 Jan.
Article in Japanese | MEDLINE | ID: mdl-35249072

ABSTRACT

In this article, we analyzed 114 adult heart transplantation( HTx) cases from 1999 to 2021. Of these cases, 94% of patients underwent left ventricular assist device ( LVAD) implantation before HTx. The mean period of LVAD support was 3.0 ±1.2 years. Thirty-day mortality was 0.8% and the 10-year survival rate was 89% after HTx. Preoperative and postoperative renal function was the prognostic factors. Long LVAD support was not associated with the long-term survival after HTx.


Subject(s)
Heart Failure , Heart Transplantation , Heart-Assist Devices , Adult , Heart Failure/surgery , Humans , Retrospective Studies , Treatment Outcome , Universities
15.
Ann Vasc Surg ; 77: 208-216, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34461238

ABSTRACT

BACKGROUND: Although the preoperative risk factors associated with the occurrence of type II endoleak (ETII) after endovascular aortic repair (EVAR) have gradually become more evident, the preoperative risk factors associated with aneurysm sac enlargement caused by ETII remain unclear. This study aimed to determine the preoperative risk factors associated with aneurysm sac enlargement caused by ETII after EVAR. METHODS: This retrospective cohort study reviewed 519 EVARs performed for true abdominal aortic aneurysm between January 2006 and December 2018 at our institution. EVARs using commercially available bifurcated devices with no type I or III endoleaks during follow-up and with ≥12 months follow-up were included. A total of 320 patients were enrolled in the study. To identify the preoperative risk factors of sac enlargement after EVAR, Cox regression analysis was used to assess preoperative data. RESULTS: The median follow-up period was 60.8 months. Overall, 135 of 320 patients (42%) had ETII during follow-up, and 47 of 135 patients (35%) developed aneurysm sac enlargement. Multivariate analysis revealed that chronic kidney disease (CKD) stage ≥4 (hazard ratio [HR], 4.65; 95% confidence interval [CI], 2.13-10.15; P = 0.001), patent inferior mesenteric artery (IMA) (HR, 17.85; 95% CI, 2.46-129.73; P< 0.001), and number of patent lumbar arteries (LAs) (HR, 1.37; 95% CI, 1.13-1.68; P= 0.002) were risk factors of aneurysm sac enlargement caused by ETII. CONCLUSIONS: CKD stage ≥4, patent IMA, and number of patent LAs were independent risk factors for aneurysm sac enlargement after EVAR. In particular, patent IMA had the highest HR and seemed to have the greatest impact on long-term aneurysm sac enlargement. Hence, taking preoperative measures to address a patent IMA appears to be important in reducing the incidence of sac enlargement.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/epidemiology , Endovascular Procedures/adverse effects , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/epidemiology , Endoleak/diagnostic imaging , Female , Humans , Incidence , Japan/epidemiology , Male , Mesenteric Artery, Inferior/physiopathology , Renal Insufficiency, Chronic/epidemiology , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
16.
J Card Surg ; 36(1): 386-389, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33135298

ABSTRACT

A 50-year-old man with decompensated aortic stenosis displayed significantly reduced ejection fraction, an ascending aortic aneurysm (55 mm in diameter), and bilateral giant bullae, and was evaluated as having extremely high surgical risk. Therefore, as a bridge to definitive treatment, he simultaneously underwent transcatheter aortic valve replacement (TAVR) and upper left lung lobectomy. His heart function recovered 6 months later and he underwent surgical aortic valve replacement (SAVR) and graft replacement of the ascending aorta. TAVR may serve as a bridge procedure before SAVR for aortic stenosis in younger patients with high surgical risk.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Male , Middle Aged , Risk Factors , Treatment Outcome
17.
J Endovasc Ther ; 27(3): 368-376, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32242769

ABSTRACT

Purpose: To identify the optimal proximal landing zone for thoracic aortic endovascular repair (TEVAR) of aortic arch pathologies so as to avoid the bird-beak phenomenon that leads to type Ia endoleak. Materials and Methods: A retrospective single-center review was conducted of 164 patients (mean age 70.3±10.8 years, range 29-93; 127 men) who underwent repairs of the aortic arch using hybrid TEVAR from April 2008 to March 2017. The patients were divided into 2 groups according to the proximal landing zone: 43 zone 0 patients (26.2%) had total debranching TEVAR (n=18) or total endovascular aortic repair (n=25) while 121 patients (73.8%) had TEVAR landing in zones 1 (n=41) or 2 (n=80). Bird-beak configurations, endoleaks, and stent migrations were assessed on the postoperative and latest computed tomography angiography (CTA) scans. Overall survival and freedom from the bird-beak configuration, aorta-related death, and aortic events were estimated using the Kaplan-Meier method. Hazard ratios (HR) were calculated with the 95% confidence interval (CI). Results: All procedures were successful, without any 30-day mortality. There were 3 early complications (1.8%; all strokes) and 10 early endoleaks (6.1%; no type Ia). On the first postoperative CTA, 42 patients (25.6%) had a bird-beak configuration. The zone 0 patients had significantly fewer (p<0.001), shorter (p<0.004), and less angulated (p<0.001) bird-beak configurations than in zones 1-2. The mean follow-up period was 4.2 years (range 0.5-8.8). There were 18 late deaths (11.0%); only one was related to the aorta (rupture due to a type Ib endoleak in a zone 0 patient). The 5-year freedom from aorta-related death was not significantly different between groups (zone 0: 96.9% vs zones 1-2: 100%, p=0.080). On the latest CTA, 51 (31.0%) patients had a bird-beak configuration; of those, 22 (13.4%) showed >3-mm progression. The freedom from bird-beak configuration estimate was significantly higher in the zone 0 group (95.4%) vs zones 1-2 (57.8%; HR 0.10, 95% CI 0.02 to 0.31, p<0.001). There were 9 late endoleaks (4 type Ia; none in the zone 0 group). The rate of stent-graft migration was significantly lower in the zone 0 group (2.3% vs 14.1% in zones 1-2, p=0.035). Conclusion: Early and most late results in zone 0 TEVAR were equal to those in zones 1 and 2; however, there were no late type Ia endoleaks and fewer bird-beak configurations associated with zone 0 TEVAR, which suggests that zone 0 landing is advantageous for preventing these complications.


Subject(s)
Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/etiology , Endovascular Procedures/adverse effects , Adult , Aged , Aged, 80 and over , Aortic Dissection/diagnostic imaging , Aortic Dissection/mortality , Aorta, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Endoleak/diagnostic imaging , Endoleak/mortality , Endoleak/prevention & control , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Humans , Male , Middle Aged , Progression-Free Survival , Retrospective Studies , Risk Assessment , Risk Factors , Stents , Time Factors
19.
Circ J ; 83(7): 1600-1606, 2019 06 25.
Article in English | MEDLINE | ID: mdl-31118365

ABSTRACT

BACKGROUND: Little is known about late outcomes after transcatheter aortic valve replacement (TAVR) in dialysis patients.Methods and Results:We enrolled 25 dialysis patients (mean age 76.5 years; mean STS score 14.7%; men 60.0%) with aortic valve stenosis undergoing TAVR at our institute. Cardiovascular mortality and stroke were defined according to the VARC-2 criteria, and major adverse cardiac and cerebrovascular events (MACCE) were investigated. Twenty-three patients (92.0%) were discharged, and the median hospital stay after TAVR was 9 days (IQR, 7.5-11 days). Mortality at 30 days was not observed. The overall survival rate at 1 and 3 years were 80.0% and 55.7%, respectively (follow-up period, 879±493 days; range, 40-1,826 days). At 1 and 3 years, rates of freedom from cardiovascular mortality, disabling stroke, and MACCE were 100% and 83.0%, 91.2% and 84.7%, and 69.8% and 39.9%, respectively. Three patients required redo-TAVR for valve dysfunction at 23, 36, and 38 months after the first TAVR, respectively (The rate of freedom from severe structural valve deterioration at 1 and 3 years was 100% and 85.9%, respectively). CONCLUSIONS: Satisfactory in-hospital outcomes were achieved in dialysis patients after TAVR. Various problems, however, such as complications particular to dialysis patients and valve durability, remained at midterm follow-up. Further studies are recommended to solve these problems, and prudent preoperative assessments should be mandatory.


Subject(s)
Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Disease-Free Survival , Female , Humans , Male , Survival Rate , Time Factors
20.
Circ J ; 82(8): 1985-1990, 2018 07 25.
Article in English | MEDLINE | ID: mdl-29952343

ABSTRACT

The 82nd Annual Scientific Meeting of the Japanese Circulation Society was held in Osaka, Japan, on March 23-25, 2018, when the cherry blossoms were just opening everywhere around the venue. This was the 5th Annual Scientific Meeting of JCS in which a cardiovascular surgeon served as Congress Chairperson. The main theme of this meeting was "Futurability: Pioneering the Future of Circulatory Medicine". The word, futurability, is a neologism of future ability, because we now have to contemplate what constitutes the essence of cardiovascular medicine, how it should develop as medicine for future generations, and how its ability should be displayed. The meeting was favored by splendid weather and the number of participants was recorded as being higher than 18,700. There were heated and profound discussions about the "futurability" of cardiology, cardiovascular surgery, and heart team medical care as well, in every session. The meeting was successfully completed and we sincerely appreciate the great cooperation and support from all affiliates.


Subject(s)
Blood Circulation , Congresses as Topic , Societies, Medical , Cardiology/trends , Cardiovascular Surgical Procedures/trends , Forecasting , Humans , Japan
SELECTION OF CITATIONS
SEARCH DETAIL