ABSTRACT
BACKGROUND: Current strategies for preventing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection are limited to nonpharmacologic interventions. Hydroxychloroquine has been proposed as a postexposure therapy to prevent coronavirus disease 2019 (Covid-19), but definitive evidence is lacking. METHODS: We conducted an open-label, cluster-randomized trial involving asymptomatic contacts of patients with polymerase-chain-reaction (PCR)-confirmed Covid-19 in Catalonia, Spain. We randomly assigned clusters of contacts to the hydroxychloroquine group (which received the drug at a dose of 800 mg once, followed by 400 mg daily for 6 days) or to the usual-care group (which received no specific therapy). The primary outcome was PCR-confirmed, symptomatic Covid-19 within 14 days. The secondary outcome was SARS-CoV-2 infection, defined by symptoms compatible with Covid-19 or a positive PCR test regardless of symptoms. Adverse events were assessed for up to 28 days. RESULTS: The analysis included 2314 healthy contacts of 672 index case patients with Covid-19 who were identified between March 17 and April 28, 2020. A total of 1116 contacts were randomly assigned to receive hydroxychloroquine and 1198 to receive usual care. Results were similar in the hydroxychloroquine and usual-care groups with respect to the incidence of PCR-confirmed, symptomatic Covid-19 (5.7% and 6.2%, respectively; risk ratio, 0.86 [95% confidence interval, 0.52 to 1.42]). In addition, hydroxychloroquine was not associated with a lower incidence of SARS-CoV-2 transmission than usual care (18.7% and 17.8%, respectively). The incidence of adverse events was higher in the hydroxychloroquine group than in the usual-care group (56.1% vs. 5.9%), but no treatment-related serious adverse events were reported. CONCLUSIONS: Postexposure therapy with hydroxychloroquine did not prevent SARS-CoV-2 infection or symptomatic Covid-19 in healthy persons exposed to a PCR-positive case patient. (Funded by the crowdfunding campaign YoMeCorono and others; BCN-PEP-CoV2 ClinicalTrials.gov number, NCT04304053.).
Subject(s)
Anti-Infective Agents/therapeutic use , COVID-19/prevention & control , Hydroxychloroquine/therapeutic use , SARS-CoV-2 , Adult , Anti-Infective Agents/adverse effects , COVID-19/transmission , COVID-19/virology , Disease Transmission, Infectious/prevention & control , Double-Blind Method , Female , Humans , Hydroxychloroquine/adverse effects , Male , Middle Aged , Patient Compliance , Treatment Failure , Viral LoadABSTRACT
INTRODUCTION AND OBJECTIVES: Medical device companies have introduced new TFL machines, including Soltive (Olympus, Japan), Fiber Dust (Quanta System, Italy), and TFLDrive (Coloplast, France). The primary objective of this study is to compare our initial clinical experiences with TFL using those devices. Through this historical comparison of Thulium Fiber Laser systems for stone lithotripsy, we aim to advance our understanding and approach toward achieving safe and effective TFL parameters. MATERIALS AND METHODS: The data for this comparative analysis were extracted from three distinct prospective series that were previously published, outlining our initial clinical experience with the Soltive (Olympus, Japan), FiberDust laser (Quanta System, Italy), and TFLDrive laser (Coloplast, France). Parameters such as stone size, stone density, laser-on time (LOT), and laser settings were meticulously recorded. Additionally, we assessed critical variables such as ablation speed (expressed in mm3/s) and Joules/mm3 for each lithotripsy procedure. RESULTS: A total of 149 patients were enrolled in this study. Among them, 120 patients were subjected to analysis concerning renal stones. Statistically significant differences were observed in the median (IQR) stone volume: 650 (127-6027) mm3 for TFLDrive, 1800 (682.8-2760) mm3 for Soltive, and 1125 (294-4000) mm3 for FiberDust (p: 0.007); while there were no differences regarding stone density among the groups. Significant variations were identified in median (IQR) pulse energy, frequency, and total power. The Soltive group exhibited lower energy levels (0.3 J vs. 0.6 J, p: 0.002) but significantly higher pulse frequency (100 Hz vs. 17.5 Hz, p: 0.003) and total power (24 W vs. 11W, p: 0.001) compared to the other groups. Laser-on time showed no substantial differences across all three groups. Additionally, a statistically significant difference was observed in median J/mm3, with the TFLDrive group using higher values (24 J/mm3, p: 0.001), while the Soltive group demonstrated a higher median ablation speed of 1.16 mm3/s (p: 0.001). The overall complication rate remained low for all groups, with comparable stone-free rates. CONCLUSION: By reducing pulsed frequency, we improved laser efficiency, but smaller volumes lead to decreased efficiency due to increased retropulsion and fragment movement. Further studies are needed to identify and establish the appropriate laser settings for this new technology.
Subject(s)
Kidney Calculi , Lasers, Solid-State , Lithotripsy, Laser , Lithotripsy , Humans , Thulium/therapeutic use , Lithotripsy, Laser/methods , Kidney Calculi/surgeryABSTRACT
OBJECTIVE: To evaluate the stone ablation rate and direct thermal damage from thulium fiber laser (TFL) lithotripsy using continuous (C) and burst (B) lasing techniques on an in vitro ureteral model. METHODS: The TFL Drive (Coloplast, Humlebaek, Denmark) was used in an in vitro saline-submerged ureteral model. Ten participants, including five junior and five experienced urologists, conducted the experimental setup with 7 different settings comparing two lasing techniques: steady-state lasing (0.5 J/10 Hz = 5W for 300 s and 0.5 J/20 Hz = 10W for 150 s) and burst, intermittent 5 s on/off lasing (0.5 J/20 Hz, 0.5 J/30 Hz, 0.5 J/60 Hz, 0.1 J/200 Hz, and 0.05 J/400 Hz) with a target cumulative energy of 1500 J using cubic 125 mm3 phantom BegoStonesTM. Ureteral damage was graded 1-3 based on the severity of burns and holes observed on the surface of the ureteral model. RESULTS: The were no significant differences in stone ablation mass neither between C and B lasing techniques, nor between expertise levels. At C lasing technique had only mild ureteral lesions with no significant differences between expertise levels (p: 0.97) or laser settings (p: 0.71). At B lasing technique, different types of thermal lesions were found with no expertise (p: 0.11) or setting (p: 0.83) differences. However, B laser setting had higher grade direct thermal lesions than C (p: 0.048). CONCLUSION: Regarding efficacy, C and B lasing techniques achieve comparable stone ablation rates. Safety-wise, B lasing mode showed higher grade of direct thermal lesions. These results should be further investigated to verify which of the lasing mode is the safest in vivo. Until then and unless proven otherwise, a C mode with low frequency should be recommended to avoid ureteral wall lesions.
Subject(s)
Lithotripsy, Laser , Thulium , Lithotripsy, Laser/methods , Lithotripsy, Laser/instrumentation , Humans , Ureter/surgery , Ureteral Calculi/surgery , In Vitro Techniques , Lasers, Solid-State/therapeutic useABSTRACT
PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.
Subject(s)
Lighting , Ureteroscopes , Humans , Equipment Design , Urologists , Disposable Equipment , UreteroscopyABSTRACT
PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.
Subject(s)
Equipment Design , Lighting , Ureteroscopes , Ureteroscopy , Light , Humans , Saline Solution , ColorABSTRACT
PURPOSE: The aim of the present study is to assess the role of indocyanine green (ICG) to evaluate distal ureteral vascularity during robot-assisted radical cystectomy (RARC) with intracorporeal urinary diversion and its impact on the incidence of benign ureteroenteric strictures (UES). METHODS: The study included patients who underwent RARC for bladder cancer between 2018 and 2023. All patients included underwent intracorporeal urinary diversion with ileal conduit or neobladder. Bricker technique was performed in all ureteroenteric anastomosis. ICG was employed during the study period to evaluate ureteral vascularity. We divided patients into 2 groups depending on the utilization of ICG during surgery and compared demographic, clinicopathological and perioperative outcomes, including benign UES rates. RESULTS: We identified 221 patients that underwent RARC with intracorporeal urinary diversion. Ileal conduit was performed in 173 (78.3%) patients and neobladder in 48 (21.7%) cases. A total of 142 (64.3%) and 79 (35.7%) patients were in the non-ICG and ICG group, respectively. With a median follow-up of the entire cohort of 21.1 months, there were no differences in the rate of benign UES after RARC between the non-ICG and the ICG group (p = 0.901). In the non-ICG group, 26 (18.3%) patients developed benign UES and in the ICG group 15 (19.0%) patients. Most of the strictures appeared in the left ureter in both groups (80.8% non-ICG vs. 66.7% ICG, p = 0.599). Median time to stricture diagnosis was 4 months (IQR 3-7.25) for the non-ICG and 3 months (IQR 2-5) for the ICG group (p = 0.091). The ICG group had a slightly greater length of ureter resected compared with the non-ICG group (1.5 vs. 1.3 cm, p = 0.007). CONCLUSION: In our experience, choosing to use ICG intraoperatively to evaluate distal ureteral vascularity may not reduce the rate of benign UES after robot-assisted radical cystectomy with intracorporeal urinary diversion and Bricker ureteroileal anastomosis.
Subject(s)
Cystectomy , Indocyanine Green , Robotic Surgical Procedures , Ureter , Urinary Bladder Neoplasms , Urinary Diversion , Humans , Urinary Diversion/methods , Cystectomy/methods , Robotic Surgical Procedures/methods , Male , Female , Middle Aged , Aged , Ureter/surgery , Urinary Bladder Neoplasms/surgery , Retrospective Studies , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Coloring Agents , Constriction, Pathologic/etiologyABSTRACT
PURPOSE: To examine temporal-spatial distribution of heat generated upon laser activation in a bench model of renal calyx. To establish reference values for a safety distance between the laser fiber and healthy tissue during laser lithotripsy. METHODS: We developed an in-vitro experimental setup employing a glass pipette and laser activation under various intra-operative parameters, such as power and presence of irrigation. A thermal camera was used to monitor both temporal and spatial temperature changes during uninterrupted 60-second laser activation. We computed the thermal dose according to Sapareto and Dewey's formula at different distances from the laser fiber tip, in order to determine a safety distance. RESULTS: A positive correlation was observed between average power and the highest recorded temperature (Spearman's coefficient 0.94, p < 0.001). Irrigation was found to reduce the highest recorded temperature, with a maximum average reduction of 9.4 °C at 40 W (p = 0.002). A positive correlation existed between average power and safety distance values (Spearman's coefficient 0.86, p = 0.001). A thermal dose indicative of tissue damage was observed at 20 W without irrigation (safety distance 0.93±0.11 mm). While at 40 W, irrigation led to slight reduction in mean safety distance (4.47±0.85 vs. 5.22±0.09 mm, p = 0.08). CONCLUSIONS: Laser settings with an average power greater than 10 W deliver a thermal dose indicative of tissue damage, which increases with higher average power values. According to safety distance values from this study, a maximum of 10 W should be used in the ureter, and a maximum of 20 W should be used in kidney in presence of irrigation.
Subject(s)
Lithotripsy, Laser , Lithotripsy, Laser/methods , Lithotripsy, Laser/instrumentation , Humans , Hot Temperature , Kidney Calices , Therapeutic Irrigation/methodsABSTRACT
PURPOSE: To evaluate whether stone dust can be obtained from all prevailing stone composition types using the novel pulsed thulium:YAG (p-Tm:YAG), including analysis of stone particle size after lithotripsy. METHODS: Human urinary stones of 7 different compositions were subjected to in vitro lithotripsy using a p-Tm:YAG laser with 270 µm silica core fibers (Thulio®, Dornier MedTech GmbH®, Wessling, Germany). A cumulative energy of 1000 J was applied to each stone using one of three laser settings: 0.1 J × 100 Hz, 0.4 J × 25 Hz and 2.0 J × 5 Hz (average power 10 W). After lithotripsy, larger remnant fragments were separated from stone dust using a previously described method depending on the floating ability of dust particles. Fragments and dust samples were then passed through laboratory sieves to evaluate stone particle count according to a semiquantitative analysis relying on a previous definition of stone dust (i.e., stone particles ≤ 250 µm). RESULTS: The p-Tm:YAG laser was able to produce stone dust from lithotripsy up to measured smallest mesh size of 63 µm in all seven stone composition types. Notably, all dust samples from all seven stone types and with all three laser settings had high counts of particles in the size range agreeing with the definition stone dust, i.e., ≤ 250 µm. CONCLUSION: This is the first study in the literature proving the p-Tm:YAG laser capable of dusting all prevailing human urinary stone compositions, with production of dust particles ≤ 250 µm. These findings are pivotal for the broader future implementation of the p-Tm:YAG in clinical routine.
Subject(s)
Lasers, Solid-State , Lithotripsy, Laser , Urinary Calculi , Humans , Lasers, Solid-State/therapeutic use , Thulium , Dust , Lithotripsy, Laser/methods , Urinary Calculi/therapyABSTRACT
PURPOSE OF REVIEW: Nowadays, due to the increase of imaging diagnosis, we identify easily renal anomalies, and we can choose between a wide range of armamentarium to treat symptomatic stones in those challenging cases. However, there is a lack of evidence and consensus on its use. The aim of this narrative review is to collect all the available data about safety and efficacity of retrograde intrarenal surgery (RIRS) in the treatment of kidney stones associated to a renal anomaly. RECENT FINDINGS: Renal anomalies are uncommon findings and even more if it has to be associated with renal stones. After a literature review of the past 2 years, there are a small number of studies that compare the outcomes in patients who have been treated with minimally invasive modalities and they are mainly focus on RIRS. SUMMARY: It is of extreme importance to know the advances on the stone treatment in anomalous kidneys. With the development of new laser technologies, RIRS is becoming a more interesting technique with high success rate and safety. Further studies are needed to make an accurate statement about the adequate surgical technique for each renal anomaly and also, clinical trials using new laser technologies.
Subject(s)
Diverticulum , Fused Kidney , Kidney Calculi , Medullary Sponge Kidney , Nephrostomy, Percutaneous , Humans , Fused Kidney/complications , Fused Kidney/diagnostic imaging , Fused Kidney/surgery , Medullary Sponge Kidney/complications , Medullary Sponge Kidney/diagnostic imaging , Medullary Sponge Kidney/surgery , Treatment Outcome , Kidney Calculi/complications , Kidney Calculi/diagnostic imaging , Kidney Calculi/surgery , Kidney/diagnostic imaging , Kidney/surgery , Retrospective Studies , Nephrostomy, Percutaneous/methodsABSTRACT
OBJECTIVE: To evaluate the new thulium fiber laser (TFL) from Quanta System (Fiber Dust™) in terms of efficiency, safety, and laser settings in laser lithotripsy during retrograde intrarenal surgery (RIRS). METHODS: A prospective study of the first 50 patients with ureteral and renal stones who underwent RIRS using the new Fiber Dust (TFL from Quanta System, Italy) was performed in a single center. 200 µm and 150 µm laser fibers were used. Stone size, stone density, laser-on time (LOT) and laser settings were recorded. We also assessed the ablation speed (mm3/s), Joules/mm3 and laser power (W) values for each procedure. RESULTS: A total of 50 patients were analyzed. The median (IQR) age was 54.5 (43-65) years old. Median (IQR) stone volume was 347 (147-1800) mm3 and 1125 (294-4000) mm3 for ureteral and renal stones, respectively. Median (IQR) stone density was 900 (400-1500) HU for ureteral stones and 950 (725-1125) HU for renal stones. Median (IQR) pulse energy was 0.6 (0.5-1) J and 0.6 (0.5-0.9) J for ureteral and renal stones, respectively. Median (IQR) frequency for ureteral stones was 10 (10-20) Hz and for renal stones, 15 (10-20) Hz. All procedures used short pulse. There were no statistically significant differences in pulse energy, frequency, laser power or LOT in both groups. The median (IQR) J/mm3 was 8.7 (4.8-65.2) for ureteral stones vs 14.3 (7.8-24.7) for renal stones. The median (IQR) ablation rate was 0.3 (0.2-1.3) mm3/s for ureteral stones vs 0.7 (0.4-1.2) mm3/s for renal stones. Neither of those results reached the significance threshold. Overall complication rate was low in both groups, and none was related to TFL. CONCLUSION: According to our results, the new TFL laser is safe and effective for lithotripsy during RIRS, using low pulse energy and low pulse frequency.
Subject(s)
Kidney Calculi , Lasers, Solid-State , Lithotripsy, Laser , Ureteral Calculi , Aged , Dust , Humans , Kidney Calculi/surgery , Lasers, Solid-State/therapeutic use , Lithotripsy, Laser/methods , Middle Aged , Prospective Studies , Thulium/therapeutic use , Ureteral Calculi/surgeryABSTRACT
INTRODUCTION: Thulium fiber laser (TFL) is a novel laser in the field of urology. There is no consensus for optimal parameters. As most urologists use social media, being Twitter the platform with the most dissemination in healthcare, we aim to review the preferred TFL settings chosen by the experts and, to evaluate their pros and cons. MATERIALS AND METHODS: A Twitter review was performed from November 2019 (firsts TFL experiences in urology) until October 2021 using the hashtags: "thuliumfiber", "ThuliumFiberLaser", "TFL" "soltive", "fiberdust", "OlympusUrology", "quanta_system", "IPG_Photonics", "rocamed". Only board-certified urologists were considered. The "tweets" selected include information about TFL preferred settings for stone lithotripsy and tissue ablation. Additionally, we also seek information regarding laser technique, fiber size, laser time, stone type and equipment. RESULTS: A total of 42 opinions were identified. The 23 endourologists have a median of 2.298 followers (range 202-10.000). Most comments were about TFL settings for kidney stone dusting (61%). There was a significant difference (p < 0.05) for kidney stone dusting settings (dusting, frequency, and power) between endourologists. Only 24% reported their fiber size, 4 reported the stone composition and 2 endourologists mentioned their type of ureteroscope. There was no discussion about technique used (burst or continuous) nor equipment. Surgery time was reported 3 times. CONCLUSION: There is no consensus in TFL pre-settings. When a pre-setting is proposed, it should also recommend technique to be used. Settings are personal and related to multiple factors, such as training, technique, equipment and fiber size.
Subject(s)
Kidney Calculi , Lasers, Solid-State , Lithotripsy, Laser , Social Media , Humans , Lasers, Solid-State/therapeutic use , Lithotripsy, Laser/methods , ThuliumABSTRACT
INTRODUCTION: Since the construction of the first laser, many companies around the world have contributed to the development of new lasers technologies. To be user-friendly, some companies have developed a pre-setting mode in their laser devices. We aimed to review and compare all laser companies' pre-settings (PS) already established in the market. MATERIALS AND METHODS: An online search of holmium:YAG (Ho:YAG) and thulium fiber laser (TFL) devices was carried out. Manual and PS mode, pulse width and pulse modulation technology data were collected. The PS parameters were collected directly from the brochure devices or by asking the companies consulting agents. RESULTS: Thirty-nine laser devices were analyzed (33 Ho:YAG and 6 TFL). The power range varies from 15 to 152 W and 35 W to 60 W for Ho:YAG and TFL, respectively. PS are present in 66% of Ho:YAG lasers and the 33% of TFL. Long-pulse modes can be modified in 12 Ho:YAG and 1 TFL lasers. The median (IQR) PS for dusting stones with Ho:YAG laser is 0.4 J (0.2-1), 21.5 Hz (5-120), and 10 W (1.5-28) for energy, frequency and power, respectively; for Ho:YAG fragmentation is 0.8 J (0.3-5), 10 (3-15) Hz and 5 (1.5-50) W for energy, frequency, and power, respectively; and for popcorn is 0.8 J (0.4-1.2), 10 Hz (6-15) and 5 W (4-18) for energy, frequency, and power, respectively. Dusting and fragmentation mode of Rocamed MH01 and EMS LaserClast 35 are programmed according to the stone type. Most of these settings do not depend on the size of the fiber being used nor the location and type of stone. For TFL, the pre-sets are divided in bladder stone, dusting, fine dusting, fragmentation, and ureteral stone. CONCLUSION: There is a huge variability regarding pre-sets offered by companies because there is no consensus. Pre-sets should provide a range to work efficacy and safety.
Subject(s)
Lasers, Solid-State , Lithotripsy, Laser , Urinary Bladder Calculi , Holmium , Humans , Lasers, Solid-State/therapeutic use , ThuliumABSTRACT
PURPOSE OF REVIEW: To confirm the need for a metabolic evaluation in stone formers based on the latest information published in the last 24 months and in the current 2022 American and European urological guidelines. RECENT FINDINGS: Recent studies suggest that urolithiasis prevalence has been increasing since 1990. Along with it, metabolic abnormalities that contribute to the development of kidney stones are also increasing, such as hyperuricosuria, hyperoxaluria, hypocitraturia, hypomagnesuria, hypocalciuria, hypophosphaturia, and hyperuricemia. Those abnormalities can only be detected through a metabolic evaluation in patients with stone disease. SUMMARY: It is important for us, urologists, to have in mind the actual stone prevalence worldwide. As part of our initial evaluation of the patient with urolithiasis, we must not forget to perform the basic metabolic analysis and, according to the patient's risk classification, continue with a deep metabolic analysis. This extensive analysis includes blood and urine tests. The urinalysis covers 24-h urinalysis, and it would be accurate to also have an early fresh urine analysis. Moreover, identifying the stone type is intimately correlated with the search for other metabolic parameters.
Subject(s)
Hyperoxaluria , Kidney Calculi , Urolithiasis , Humans , Kidney Calculi/diagnosis , Kidney Calculi/epidemiology , Kidney Calculi/etiology , Prevalence , Risk Factors , Urinalysis , Urolithiasis/diagnosis , Urolithiasis/epidemiologyABSTRACT
BACKGROUND: No effective treatments for coronavirus disease 2019 (COVID-19) exist. We aimed to determine whether early treatment with hydroxychloroquine (HCQ) would be efficacious for outpatients with COVID-19. METHODS: Multicenter open-label, randomized, controlled trial conducted in Catalonia, Spain, between 17 March and 26 May 2020. Patients recently diagnosed with <5-day of symptom onset were assigned to receive HCQ (800 mg on day 1 followed by 400 mg once daily for 6 days) or usual care. Outcomes were reduction of viral load in nasopharyngeal swabs up to 7 days after treatment start, disease progression up to 28 days, and time to complete resolution of symptoms. Adverse events were assessed up to 28 days. RESULTS: A total of 293 patients were eligible for intention-to-treat analysis: 157 in the control arm and 136 in the intervention arm. The mean age was 41.6 years (SD, 12.6), mean viral load at baseline was 7.90 log10 copies/mL (SD, 1.82), and median time from symptom onset to randomization was 3 days. No differences were found in the mean reduction of viral load at day 3 (-1.41 vs -1.41 log10 copies/mL in the control and intervention arm, respectively) or at day 7 (-3.37 vs -3.44). Treatment did not reduce risk of hospitalization (7.1% control vs 5.9% intervention) nor shorten the time to complete resolution of symptoms (12 days, control vs 10 days, intervention). No relevant adverse events were reported. CONCLUSIONS: In patients with mild COVID-19, no benefit was observed with HCQ beyond the usual care.
Subject(s)
COVID-19 Drug Treatment , Hydroxychloroquine , Adult , Humans , Hydroxychloroquine/therapeutic use , SARS-CoV-2 , Treatment OutcomeABSTRACT
INTRODUCTION: The current pool of organs available for transplantation does not cover requirements, for this reason non-standard risk donors need to be incorporated into the pool. In this way, donors with small renal tumour are considered for transplantation after bench tumour excision. The aim of our study was to analyse our experience in using these grafts for transplantation. MATERIALS AND METHODS: Retrospective analysis from our prospective accrued database of donors with incidental renal mass used for kidney transplantation between January 2007 and August 2018. RESULTS: Twenty kidney transplantations were performed, thirteen cases received the affected kidney (after tumour removal) and seven the contralateral kidney; from six living and eleven deceased donors. Donor and recipient median age was 58 years (range 22-82) and 56.5 years (range 38-74), respectively. Mean tumour diameter was 12.7 mm (SD 9.5). Tumours resulted in two benign lesions and fifteen renal cell carcinoma. Surgical margins were negative. Two cases presented with bleeding after reperfusion was solved without repercussion. One case presented with immediate vein thrombosis. None of them present delayed graft function. After a 69 month follow-up none of the donors or the recipients presented tumour recurrence. CONCLUSIONS: Kidneys with small incidental tumours seem to be a good option for kidney transplantation in selected patients after bench surgery excision with good functional and oncologic results. More studies and longer follow-up are needed to confirm these results.
Subject(s)
Kidney Neoplasms , Kidney Transplantation , Tissue and Organ Procurement/methods , Tissue and Organ Procurement/statistics & numerical data , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Young AdultABSTRACT
Objective: To evaluate the ablation speed (AS), laser efficiency and direct thermal lesions during urinary stone lithotripsy with the current available laser technologies: Holmium:YAG (Ho:YAG), pulsed-Thulium:YAG (p-Tm:YAG) and thulium fiber laser (TFL) in vitro using different laser settings. Materials and Methods: Ho:YAG, p-Tm:YAG, and TFL laser system were used in an in vitro ureteral model with a volume of 125 mm3 Begostone. The following parameters were tested across all laser devices: 0.6J/10 Hz (6 W), 0.6 J/20 Hz (12 W), 1.5 J/10 Hz (15 W), and 1.5 J/20 Hz (30 W), employing short pulse width for all lasers and long pulse width for Ho:YAG and p-Tm:YAG. Ten participants conducted the experimental setup during 3-minutes laser on time, combining the laser technology, settings, and pulse widths, with a total of 20 different combinations. The efficiency, AS and ureteral damage resulting from each intervention were analyzed. Results: p-Tm:YAG and TFL demonstrated significantly higher efficiency compared with Ho:YAG (0.049 ± 0.02 Δgr/KJ and 0.042 ± 0.01 Δgr/KJ vs 0.029 ± 0.01 Δgr/KJ; p < 0.05). In all laser sources, as the power increases, the AS also increases (p < 0.05). Furthermore, only at high-energy settings (1.5 J) higher frequency led to increase AS (p < 0.05). Both, p-Tm:YAG and TFL exhibited higher AS compared to Ho:YAG (0.64 ± 0.33 Δgr/s and 0.62 ± 0.31 Δgr/s vs 0.44 ± 0.22 Δgr/s; p < 0.05). Regarding ureteral injuries, as the power increases, there is a higher chance of ureteral damage (p = 0.031). No differences were observed between laser technologies (p = 0.828). Conclusions: Both, p-Tm:YAG and TFL exhibited superior performances during laser lithotripsy compared with Ho:YAG, as they demonstrated higher efficiency and ablation speed. Thermal damage did not appear to be associated with specific laser equipment, but higher grades of lesions are described by increasing power.
ABSTRACT
Social media (SoMe) is now a core part of modern-day life with increased use among both patients and urologists. The interplay of SoMe between these two parties is complex. From a patient perspective, SoMe platforms can serve as educational tools as well as communication portals to support networks and patient communities. However, studies report the educational value of content online is often poor and may contain misinformation. For urologists, SoMe can lead to research collaborations, networking and educational content but areas of concern include the potential negative impact SoMe can have on mental health and sharing of patient images without appropriate consent. This review serves to provide an overview of the interaction between SoMe and urology practice and provide practical guidance to navigating it.
Subject(s)
Social Media , Urology , HumansABSTRACT
BACKGROUND: To maximize the availability of suitable grafts and ensure effective management, several reports have demonstrated successful outcomes when using kidney grafts with urolithiasis. This multicenter study reports on the management and long-term outcomes of kidney transplantation using renal grafts with lithiasis. METHODS: Retrospective data from three Spanish hospitals were analyzed for kidney transplants involving grafts with nephrolithiasis performed between December 2009 and August 2023. The study included adult patients, excluding those with incomplete records. It evaluated stone characteristics, complications, and outcomes in recipients and in living kidney donors. RESULTS: Out of 38 analyzed kidney transplants, 57.9% were cadaveric and 42.1% were from living kidney donors. Most diagnoses were incidental during donor evaluation, with an average stone size of 7.06 mm. After follow-up (median 26 months), all recipients but one had functioning grafts, and there were no stone recurrences in both recipients and living kidney donors. Conservative management was adopted in 28 cases, while 10 cases required ex-vivo flexible ureterorenoscopy for stone removal. Following conservative management, 5 patients needed additional treatments for stone-related events. CONCLUSIONS: Kidneys with lithiasis can be considered for transplantation in selected cases, resulting in good functional outcomes with no stone recurrence in recipients or living donors.
Subject(s)
Kidney Transplantation , Living Donors , Humans , Retrospective Studies , Male , Female , Middle Aged , Spain , Adult , Aged , Kidney Calculi/surgery , Treatment Outcome , Conservative Treatment , CadaverABSTRACT
OBJECTIVE: To conduct a systematic review (SR) of literature to assess the existing evidence concerning the success and complications of endourological ex vivo stone surgeries. METHODS: Eligible studies for inclusion focused on investigating the success and/or complications related to endourological ex vivo surgeries in donors with nephrolithiasis. A SR was undertaken in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The search included databases of Web of Science, PubMed, and Scopus and only article in English were included. Studies published between 2002 and 2023 included in this SR. RESULTS: After screening 1726 abstracts, this SR included 16 studies with a total of 209 patients. The mean stone size was 5.6 mm and majority of kidneys contained single stones, located in the lower calyx. After ex vivo endourological stone surgeries, the average stone-free rate was found to be 95.4%. The mean duration of ex vivo surgery was 17.3 minutes. Regarding intraoperative complications, two patients (1%) experienced mucosal injuries during pneumatic lithotripsy. As for postoperative complications, two patients (1%) experienced vascular complications. In terms of urological complications, hematuria was observed in 24 patients (11.5%), while one patient (0.5%) experienced clot formation in renal pelvis. Seven patients (3.3%) had urinary tract infections, and three patients (1.4%) developed urolithiasis during the follow-up. Additionally, one patient (0.5%) experienced complete occlusion of ureteroneocystostomy and required revision. CONCLUSION: Given the advancements in current technology and techniques, endourological ex vivo stone surgeries are increasingly recognized as an effective and safe option for donors with nephrolithiasis. TRIAL REGISTRATION: This systematic review was registered under the protocol registration number CRD42024538384/PROSPERO.
Subject(s)
Kidney Calculi , Kidney Transplantation , Humans , Intraoperative Complications/etiology , Intraoperative Complications/epidemiology , Kidney Calculi/surgery , Kidney Transplantation/adverse effects , Kidney Transplantation/methods , Lithotripsy/methods , Lithotripsy/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Treatment OutcomeABSTRACT
Purpose: To analyze the utility and outcomes of available endourologic options to treat ureteral stricture after kidney transplantation (KT). Methods: A systematic review was carried out for all English language articles from 2000 to 2023 according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) standards using EMBASE, MEDLINE, SCOPUS, Google scholar, and Cochrane library. The search term combination for the string was follows: [(Ureteral stricture) OR (ureter stenosis) OR (ureteral stenosis) OR (Stricture ureter) OR (Narrowing ureter) OR (Ureter restriction) OR (ureteral restriction) OR (ureteral narrowing) OR (ureteral obstruction) OR (ureter obstruction) OR (obstructing ureter) OR (obstructive ureter) OR (narrow ureter) OR (ureteral narrow)] AND [(kidney transplant) OR (transplanted kidney) OR (transplant) OR (transplantation)] AND [(management) OR (Robotic) OR (laser) OR (stent) OR (dilatation) OR (dilation) OR (endoscopic) OR (endourological) OR (Urologic) OR (laparoscopic) OR (surgery) OR (treatment)]. Case reports, review articles, animal and laboratory studies were excluded. Risk of bias assessment was conducted using the RoB 2 and ROBINS-I tools. Results: A total of 1102 relevant articles published from 2000 to 2023 were found. After screening of titles and abstracts, a total of 19 articles were included in our systematic review. Ureteral stent/nephrostomy placement, balloon dilatation (ureteroplasty) with or without laser was used as initial approaches whereas follow-up and success rate were analyzed among other parameters. Conclusions: The management of ureteral strictures after KT is challenging and selecting the most appropriate treatment is crucial for successful outcomes. Our review suggests that, an endourologic management is a safe option with good long-term outcomes, especially in short and early strictures.