Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Article in English | MEDLINE | ID: mdl-36842794

ABSTRACT

Many patients are born with lymphatic abnormalities or are susceptible to pathology following cardiac surgery. It therefore becomes important to evaluate and treat lymphatic disorders in centers performing congenital heart surgery. Programs can make strides towards starting a lymphatic branch if appropriately equipped with proper staff, tools, and other capabilities to perform lymphatic system access, imaging, and intervention. In reality, many of these components already exist in most centers, and a successful and comprehensive program can be established by enlisting these already established services.


Subject(s)
Cardiac Surgical Procedures , Lymphatic Abnormalities , Lymphatic Diseases , Lymphatic Vessels , Humans , Lymphatic System , Lymphatic Abnormalities/surgery
2.
Catheter Cardiovasc Interv ; 97(3): 451-458, 2021 02 15.
Article in English | MEDLINE | ID: mdl-33283447

ABSTRACT

OBJECTIVES: To determine over-dilation potential of commercially available covered stents. BACKGROUND: Covered stents including the Atrium iCast, Gore VBX, and Lifestream stents (LS) can treat ruptures, dissections, and aneurysms in small vessels. Especially in growing patients, stents often require serial dilations beyond their implant or nominal diameters. Tolerance of serial dilations is clinically important information for interventionalists. METHODS: Serial dilations of 5-12 mm iCast, VBX, and LS covered stents were performed in 1-2 mm increments (up to 20 mm). With each dilation, foreshortening and recoil were measured, and stent strut and covering integrity were assessed. High-pressure balloons were used to expand the stents until they fractured or could not be further expanded. RESULTS: The 5-8 mm LS tolerated dilation to 14.5-16 mm. The 10-12 mm LS stents tolerated dilation to 18 mm and fractured on the 20 mm balloon. LS stents foreshortened 35%-45% on average after 8 mm of over-dilation and had 5%-10% recoil on <6 mm over-dilation. All iCast stents tolerated dilation to 12-13 mm and required fracture for dilation to >14 mm. ICast stents foreshortened 19%-29% at maximum dilation, with 3-6% recoil on <2 mm over-dilation, and < 3% thereafter. VBX stents over-dilated to 2.9-4.7 mm above nominal, foreshortening 40%-50% after 4-6 mm of over-dilation before collapsing into a ring. VBX stent recoil was <2.5% on all dilations. CONCLUSIONS: LS stents had the greatest over-dilation potential. VBX stents had the least recoil but tended to foreshorten significantly 3-4 mm above nominal. Regardless of nominal size, all iCast stents (including the 5 mm) tolerated dilation to a maximum of 12-13 mm.


Subject(s)
Stents , Dilatation , Humans , Prosthesis Design , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL