Magn Reson Med ; 90(3): 1209-1218, 2023 09.
Article in English | MEDLINE | ID: mdl-37125658

ABSTRACT

PURPOSE: To (a) develop a preconditioned water-fat-silicone total field inversion (wfsTFI) algorithm that directly estimates the susceptibility map from complex multi-echo data in the breast in the presence of silicone and to (b) evaluate the performance of wfsTFI for breast quantitative susceptibility mapping (QSM) in silico and in vivo in comparison with formerly proposed methods. METHODS: Numerical simulations and in vivo multi-echo gradient echo breast measurements were performed to compare wfsTFI to a previously proposed field map-based linear total field inversion algorithm (lTFI) with and without the consideration of the chemical shift of silicone in the field map estimation step. Specifically, a simulation based on an in vivo scan and data from five patients were included in the analysis. RESULTS: In the simulation, wfsTFI is able to significantly decrease the normalized root mean square error from lTFI without (4.46) and with (1.77) the consideration of the chemical shift of silicone to 0.68. Both the in silico and in vivo wfsTFI susceptibility maps show reduced shadowing artifacts in local tissue adjacent to silicone, reduced streaking artifacts and no erroneous single voxels of diamagnetic susceptibility in proximity to silicone. CONCLUSION: The proposed wfsTFI method can automatically distinguish between subjects with and without silicone. Furthermore wfsTFI accounts for the presence of silicone in the QSM dipole inversion and allows for the robust estimation of susceptibility in proximity to silicone breast implants and hence allows the visualization of structures that would otherwise be dominated by artifacts on susceptibility maps.


Subject(s)
Breast , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Breast/diagnostic imaging , Algorithms , Artifacts , Computer Simulation , Water , Brain Mapping/methods , Brain , Image Processing, Computer-Assisted/methods
2.
NMR Biomed ; 35(8): e4722, 2022 08.
Article in English | MEDLINE | ID: mdl-35226966

ABSTRACT

Longitudinally orientated dipoles and microstrip antennas have both demonstrated superior results as RF transmit elements for body imaging at 7 T MRI, and are as of today the most commonly used transmit elements. In this study, the performances of the two antenna concepts were compared for use in local RF antenna arrays by numerical simulations. Antenna elements investigated are the fractionated dipole and the microstrip line with meander structures. Phantom simulations with a single antenna element were performed and evaluated with regard to specific absorption rate (SAR) efficiency in the center of the subject. Simulations of array configurations with 8 and 16 elements were performed with anatomical body models. Both antenna elements were combined with a loop coil to compare hybrid configurations. Singular value decomposition of the B1+ fields, RF shimming, and calculation of the voxel-wise power and SAR efficiencies were performed in regions of interest with varying sizes to evaluate the transmit performance. The signal-to-noise ratio (SNR) was evaluated to estimate the receive performance. Simulated data show similar transmit profiles for the two antenna types in the center of the phantom (penetration depth > 20 mm). For body imaging, no considerable differences were determined for the different antenna configurations with regard to the transmit performance. Results show the advantage of 16 transmit channels compared with today's commonly used 8-channel systems (minimum RF shimming excitation error of 4.7% (4.3%) versus 2.7% (2.8%) for the 8-channel and 16-channel configurations with the microstrip antennas in a (5 cm)3 cube in the center of a male (female) body model). Highest SNR is achieved for the 16-channel configuration with fractionated dipoles. The combination of either fractionated dipoles or microstrip antennas with loop coils is more favorable with regard to the transmit performance compared with only increasing the number of elements.


Subject(s)
Magnetic Resonance Imaging , Models, Anatomic , Equipment Design , Female , Humans , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Male , Phantoms, Imaging , Signal-To-Noise Ratio
3.
NMR Biomed ; 35(5): e4656, 2022 05.
Article in English | MEDLINE | ID: mdl-34962689

ABSTRACT

In this study, the performance of an integrated body-imaging array for 7 T with 32 radiofrequency (RF) channels under consideration of local specific absorption rate (SAR), tissue temperature, and thermal dose limits was evaluated and the imaging performance was compared with a clinical 3 T body coil. Thirty-two transmit elements were placed in three rings between the bore liner and RF shield of the gradient coil. Slice-selective RF pulse optimizations for B1 shimming and spokes were performed for differently oriented slices in the body under consideration of realistic constraints for power and local SAR. To improve the B1+ homogeneity, safety assessments based on temperature and thermal dose were performed to possibly allow for higher input power for the pulse optimization than permissible with SAR limits. The results showed that using two spokes, the 7 T array outperformed the 3 T birdcage in all the considered regions of interest. However, a significantly higher SAR or lower duty cycle at 7 T is necessary in some cases to achieve similar B1+ homogeneity as at 3 T. The homogeneity in up to 50 cm-long coronal slices can particularly benefit from the high RF shim performance provided by the 32 RF channels. The thermal dose approach increases the allowable input power and the corresponding local SAR, in one example up to 100 W/kg, without limiting the exposure time necessary for an MR examination. In conclusion, the integrated antenna array at 7 T enables a clinical workflow for body imaging and comparable imaging performance to a conventional 3 T clinical body coil.


Subject(s)
Magnetic Resonance Imaging , Radio Waves , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Temperature
4.
IEEE Trans Med Imaging ; 41(11): 3253-3265, 2022 11.
Article in English | MEDLINE | ID: mdl-35657831

ABSTRACT

Water-fat separation is a non-linear non-convex parameter estimation problem in magnetic resonance imaging typically solved using spatial constraints. However, there is still limited knowledge on how to separate in vivo three chemical species in the presence of magnetic field inhomogeneities. The proposed method uses multiple graph-cuts in a hierarchical multi-resolution framework to perform robust chemical species separation in the breast for subjects with and without silicone implants. Experimental results show that the proposed method can decrease the computational time for water-fat separation and perform accurate water-fat-silicone separation with only a limited number of acquired echo images at 3 T. The silicone-separated images have an improved spatial resolution and image contrast compared to conventional scans used for regular monitoring of the silicone implant's integrity.


Subject(s)
Silicones , Water , Humans , Algorithms , Adipose Tissue , Magnetic Resonance Imaging/methods