Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 76
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Med Sci Monit ; 30: e943321, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38863180

ABSTRACT

BACKGROUND This study explored the integration of conductive threads into a microfluidic compact disc (CD), developed using the xurographic method, for a potential sweat biosensing platform. MATERIAL AND METHODS The microfluidic CD platform, fabricated using the xurographic method with PVC films, included venting channels and conductive threads linked to copper electrodes. With distinct microfluidic sets for load and metering, flow control, and measurement, the CD's operation involved spinning for sequential liquid movement. Impedance analysis using HIOKI IM3590 was conducted for saline and artificial sweat solutions on 4 identical CDs, ensuring reliable conductivity and measurements over a 1 kHz to 200 kHz frequency range. RESULTS Significant differences in |Z| values were observed between saline and artificial sweat treatments. 27.5 µL of saline differed significantly from 27.5 µL of artificial sweat, 72.5 µL of saline from 72.5 µL of artificial sweat, and 192.5 µL of saline from 192.5 µL of sweat. Significant disparities in |Z| values were observed between dry fibers and Groups 2, 3, and 4 (varying saline amounts). No significant differences emerged between dry fibers and Groups 6, 7, and 8 (distinct artificial sweat amounts). These findings underscore variations in fiber characteristics between equivalent exposures, emphasizing the nuanced response of the microfluidic CD platform to different liquid compositions. CONCLUSIONS This study shows the potential of integrating conductive threads in a microfluidic CD platform for sweat sensing. Challenges in volume control and thread coating degradation must be addressed for transformative biosensing devices in personalized healthcare.


Subject(s)
Biosensing Techniques , Lab-On-A-Chip Devices , Sweat , Sweat/chemistry , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Humans , Microfluidics/methods , Microfluidics/instrumentation , Electric Conductivity , Electrodes , Electric Impedance
2.
Med Sci Monit ; 30: e944050, 2024 Jul 07.
Article in English | MEDLINE | ID: mdl-38971968

ABSTRACT

BACKGROUND Measurement of bite force plays a crucial role in assessment of the masticatory system. With a growing interest in detecting occlusal irregularities, bite force sensors have garnered attention in the biomedical field. This study aimed to introduce a hydrogel bite force sensor, based on hydroxyethyl-cellulose-fructose-water (HEC-F-water), for premolar and molar teeth, and to evaluate it using optical profilometry, infrared spectroscopy (FTIR), and Instron Tension testing system, with 2.5 cm (1 inch) margins at top, bottom, right, and left. MATERIAL AND METHODS We fabricated 20 HEC-F-water hydrogel samples sized with surface of 1×1 cm, with 2 different widths - 1 mm and 5 mm. The samples were characterized using optical profilometry and FTIR and their electrical characteristics were determined using an impedance analyzer. Aluminum (Al) electrodes, fabricated using Cutting Plotter, were used to form a HEC-F-water-based transducer, which was used for bite force sensing. The Instron tensile testing system was employed, utilizing 3D printed models of the upper and lower jaw, to simulate biting. Forces in the range between 40 N and 540 N were exerted upon the transducer, and the output change in the electrical signal was measured. RESULTS The study determined the transfer function between bite force and capacitance. The fabricated sensor exhibited a sensitivity of 3.98 pF/N, an input range of 500 N, output range of 2 nF, and accuracy of 95.9%. CONCLUSIONS This study introduces an edible bite force sensor employing an edible hydrogel as a dielectric, presenting a novel avenue in the development of edible sensorics in dentistry.


Subject(s)
Bite Force , Humans , Hydrogels/chemistry , Molar , Fructose , Mastication/physiology , Spectroscopy, Fourier Transform Infrared/methods , Cellulose/chemistry , Water , Bicuspid
3.
Sensors (Basel) ; 22(2)2022 Jan 14.
Article in English | MEDLINE | ID: mdl-35062598

ABSTRACT

The incidence of diabetes is increasing at an alarming rate, and regular glucose monitoring is critical in order to manage diabetes. Currently, glucose in the body is measured by an invasive method of blood sugar testing. Blood glucose (BG) monitoring devices measure the amount of sugar in a small sample of blood, usually drawn from pricking the fingertip, and placed on a disposable test strip. Therefore, there is a need for non-invasive continuous glucose monitoring, which is possible using a sweat sensor-based approach. As sweat sensors have garnered much interest in recent years, this study attempts to summarize recent developments in non-invasive continuous glucose monitoring using sweat sensors based on different approaches with an emphasis on the devices that can potentially be integrated into a wearable platform. Numerous research entities have been developing wearable sensors for continuous blood glucose monitoring, however, there are no commercially viable, non-invasive glucose monitors on the market at the moment. This review article provides the state-of-the-art in sweat glucose monitoring, particularly keeping in sight the prospect of its commercialization. The challenges relating to sweat collection, sweat sample degradation, person to person sweat amount variation, various detection methods, and their glucose detection sensitivity, and also the commercial viability are thoroughly covered.


Subject(s)
Biosensing Techniques , Wearable Electronic Devices , Blood Glucose , Blood Glucose Self-Monitoring , Glucose , Humans , Sweat
4.
Sensors (Basel) ; 22(7)2022 Mar 29.
Article in English | MEDLINE | ID: mdl-35408213

ABSTRACT

Wireless sensor networks (WSNs) have received considerable interest in recent years. These sensor nodes can gather information from the surrounding environment and transmit it to a designated location. Each sensor node in WSN typically has a battery with a limited capacity. Due to their large number and because of various environmental challenges, it is sometimes hard to replace this finite battery. As a result, energy-efficient communication is seen as a critical aspect in extending the lifespan of a sensor node. On the other hand, some applications that require large coverage and generate various sorts of data packets require multi-hop routing and quality of service (QoS) features. Therefore, in order to avoid network failure, these applications need an energy-efficient QoS MAC protocol that can support multiple levels of data packet priority and multi-hop routing features while focusing on energy conservation. An energy-aware QoS MAC protocol based on Prioritized Data and Multi-hop routing (EQPD-MAC) is proposed in this article. The EQPD-MAC protocol offers a simple yet effective cross-layer communication method. It provides timely delivery of multi-priority packets, uses an adaptive active time to limit idle listening, and integrates a robust routing protocol. Finally, the EQPD-MAC protocol's performance was evaluated and compared to three other well-known QoS MAC protocols. The simulation findings show that the proposed protocol significantly decreases sensor node energy consumption by up to 30.3%, per-bit energy consumption by up to 29.6%, sink node energy consumption by up to 27.4% and increases throughput by up to 23.3%.

5.
Sensors (Basel) ; 22(21)2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36366073

ABSTRACT

The rapid growth of the world population has increased the food demand as well as the need for assurance of food quality, safety, and sustainability. However, food security can easily be compromised by not only natural hazards but also changes in food preferences, political conflicts, and food frauds. In order to contribute to building a more sustainable food system-digitally visible and processes measurable-within this review, we summarized currently available evidence for various information and communication technologies (ICTs) that can be utilized to support collaborative actions, prevent fraudulent activities, and remotely perform real-time monitoring, which has become essential, especially during the COVID-19 pandemic. The Internet of Everything, 6G, blockchain, artificial intelligence, and digital twin are gaining significant attention in recent years in anticipation of leveraging the creativity of human experts in collaboration with efficient, intelligent, and accurate machines, but with limited consideration in the food supply chain. Therefore, this paper provided a thorough review of the food system by showing how various ICT tools can help sense and quantify the food system and highlighting the key enhancements that Industry 5.0 technologies can bring. The vulnerability of the food system can be effectively mitigated with the utilization of various ICTs depending on not only the nature and severity of crisis but also the specificity of the food supply chain. There are numerous ways of implementing these technologies, and they are continuously evolving.


Subject(s)
Blockchain , COVID-19 , Humans , Pandemics/prevention & control , Artificial Intelligence , Food Security
6.
Sci Technol Adv Mater ; 22(1): 772-793, 2021.
Article in English | MEDLINE | ID: mdl-34552390

ABSTRACT

Wearable power supply devices and systems are important necessities for the emerging textile electronic applications. Current energy supply devices usually need more space than the device they power, and are often based on rigid and bulky materials, making them difficult to wear. Fabric-based batteries without any rigid electrical components are therefore ideal candidates to solve the problem of powering these devices. Printing technologies have greater potential in manufacturing lightweight and low-cost batteries with high areal capacity and generating high voltages which are crucial for electronic textile (e-textile) applications. In this review, we present various printing techniques, and battery chemistries applied for smart fabrics, and give a comparison between them in terms of their potential to power the next generation of electronic textiles. Series combinations of many of these printed and distributed battery cells, using electrically conducting threads, have demonstrated their ability to power different electronic devices with a specific voltage and current requirements. Therefore, the present review summarizes the chemistries and material components of several flexible and textile-based batteries, and provides an outlook for the future development of fabric-based printed batteries for wearable and electronic textile applications with enhanced level of DC voltage and current for long periods of time.

7.
Sensors (Basel) ; 21(23)2021 Nov 26.
Article in English | MEDLINE | ID: mdl-34883867

ABSTRACT

Lately, wearable applications featuring photonic on-chip sensors are on the rise. Among many ways of controlling and/or modulating, the acousto-optic technique is seen to be a popular technique. This paper undertakes the study of different multilayer structures that can be fabricated for realizing an acousto-optic device, the objective being to obtain a high acousto-optic figure of merit (AOFM). By varying the thicknesses of the layers of these materials, several properties are discussed. The study shows that the multilayer thin film structure-based devices can give a high value of electromechanical coupling coefficient (k2) and a high AOFM as compared to the bulk piezoelectric/optical materials. The study is conducted to find the optimal normalised thickness of the multilayer structures with a material possessing the best optical and piezoelectric properties for fabricating acousto-optic devices. Based on simulations and studies of SAW propagation characteristics such as the electromechanical coupling coefficient (k2) and phase velocity (v), the acousto-optic figure of merit is calculated. The maximum value of the acousto-optic figure of merit achieved is higher than the AOFM of all the individual materials used in these layer structures. The suggested SAW device has potential application in wearable and small footprint acousto-optic devices and gives better results than those made with bulk piezoelectric materials.


Subject(s)
Transducers , Wearable Electronic Devices , Equipment Design , Equipment Failure Analysis , Optics and Photonics
8.
Sensors (Basel) ; 21(11)2021 May 24.
Article in English | MEDLINE | ID: mdl-34073687

ABSTRACT

Wireless sensors networks (WSNs) are characterized by flexibility and scalability in any environment. These networks are increasingly used in agricultural and industrial environments and have a dual role in data collection from sensors and transmission to a monitoring system, as well as enabling the management of the monitored environment. Environment management depends on trust in the data collected from the surrounding environment, including the time of data creation. This paper proposes a trust model for monitoring humidity and moisture in agricultural and industrial environments. The proposed model uses a digital signature and public key infrastructure (PKI) to establish trust in the data source, i.e., the trust in the sensor. Trust in data generation is essential for real-time environmental monitoring and subsequent analyzes, thus timestamp technology is implemented here to further ensure that gathered data are not created or changed after the assigned time. Model validation is performed using the Castalia network simulator by testing energy consumption at the receiver and sender nodes and the delay incurred by creating or validating a trust token. In addition, validation is also performed using the Ascertia TSA Crusher application for the time consumed to obtain a timestamp from the free TSA. The results show that by applying different digital signs and timestamps, the trust entity of the WSN improved significantly with an increase in power consumption of the sender node by up to 9.3% and receiver node by up to 126.3% for a higher number of nodes, along with a packet delay of up to 15.6% and an average total time consumed up to 1.186 s to obtain the timestamp from the best chosen TSA, which was as expected.

9.
Sensors (Basel) ; 20(21)2020 Nov 06.
Article in English | MEDLINE | ID: mdl-33171890

ABSTRACT

This study aims to discuss the synthesis and fabrication of SnO2-In2O3-based thick-films and their biosensing applications. The structural characterization of SnO2-In2O3 nanocomposites was performed using X-ray diffraction, Raman spectroscopy and transmission electron microscopy. Furthermore, the screen-printing technology was used in the fabrication of conductive electrodes to form an interdigitated capacitive structure, and the sensor layer based on the mixture of SnO2 and In2O3. Moreover, the sensing performance of the developed structure was tested using Pseudomonas aeruginosa (P. aeruginosa) and Staphylococcus aureus (S. aureus) bacteria. In addition, the validation of sensing characteristics was performed by electrochemical impedance spectroscopic and self-resonant frequency analysis. Finally, the sensing properties were analyzed for two consecutive days, and changes in both P. aeruginosa and S. aureus pathogens growing media were also studied.


Subject(s)
Nanocomposites , Staphylococcus aureus , Biosensing Techniques , Electrodes , X-Ray Diffraction
10.
Saudi Pharm J ; 28(2): 165-171, 2020 Feb.
Article in English | MEDLINE | ID: mdl-32042255

ABSTRACT

Bile acids (BAs) are amphiphilic compounds and of recently have demonstrated wide range of formulation stabilizing effects. A recent study showed that primary un-metabolised bile acids (PUBAs) have ß-cell protective effects, and synergistic antidiabetic effects when combined with antioxidant and anti-inflammatory drugs, such as probucol (PB). Thus, this study aimed to design and test microcapsules containing a PUBA incorporated with PB and an alginate-Eudragit matrix. Six types of microcapsules were developed without (control) or with (test) PUBA, and tested for internal and external features and ß-cell protective effects. The incorporation of PB-alginate-Eudragit with PUBA produced stable microcapsules but did not exert consistent positive effects on cell viability in the hyperglycaemic state, which suggests that PUBA in alginate-Eudragit matrices did not exhibit synergistic effects with PB nor exerted antidiabetic effects.

11.
Sensors (Basel) ; 19(7)2019 Apr 10.
Article in English | MEDLINE | ID: mdl-30974880

ABSTRACT

Microfluidics, one of the most attractive and fastest developed areas of modern science and technology, has found a number of applications in medicine, biology and chemistry. To address advanced designing challenges of the microfluidic devices, the research is mainly focused on development of efficient, low-cost and rapid fabrication technology with the wide range of applications. For the first time, this paper presents fabrication of microfluidic chips using hybrid fabrication technology-a grouping of the PVC (polyvinyl chloride) foils and the LTCC (Low Temperature Co-fired Ceramics) Ceram Tape using a combination of a cost-effective xurography technique and a laser micromachining process. Optical and dielectric properties were determined for the fabricated microfluidic chips. A mechanical characterization of the Ceram Tape, as a middle layer in its non-baked condition, has been performed and Young's modulus and hardness were determined. The obtained results confirm a good potential of the proposed technology for rapid fabrication of low-cost microfluidic chips with high reliability and reproducibility. The conducted microfluidic tests demonstrated that presented microfluidic chips can resist 3000 times higher flow rates than the chips manufactured using standard xurography technique.

12.
Sensors (Basel) ; 19(4)2019 Feb 18.
Article in English | MEDLINE | ID: mdl-30781694

ABSTRACT

In the paper the description of an experiment for a comparative analysis of two different methods for deformation determination, geodetic and 2D deflection sensors based on fiber-optic curvature sensors (FOCSs) is given. The experiment is performed by a using specially designed assembly which makes it possible to apply both methods. For performing geodetic measurements, a geodetic micro-network is established. Measurements by applying a 2D deflection sensor and three total stations are carried out for comparison. The data processing comprises graphical and numerical analysis of the results. Based on the presented results the potential of 2D deflection sensor application in structural health monitoring (SHM) procedures is indicated. The analysis of the measurement results also indicates the importance of integrating various types of sensors for obtaining more accurate and more reliable deformation measurements results.

13.
Pharm Dev Technol ; 24(10): 1272-1277, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31557068

ABSTRACT

Studies in our laboratory have shown potential applications of the anti-atherosclerotic drug probucol (PB) in diabetes due to anti-inflammatory and ß-cell protective effects. The anti-inflammatory effects were optimized by incorporation of the anti-inflammatory bile acid, ursodeoxycholic acid (UDCA). This study aimed to test PB absorption, tissue accumulation profiles, effects on inflammation and type 1 diabetes prevention when combined with UDCA. Balb/c mice were divided into three equal groups and gavaged daily PB powder, PB microcapsules or PB-UDCA microcapsules for one week, at a constant dose. Mice were injected with a single dose of intraperitoneal/subcutaneous alloxan to induce type-1 diabetes and once diabetes was confirmed, treatments were continued for 3 days. Mice were euthanized and blood and tissues collected for analysis of PB and cytokine levels. The PB-UDCA group showed the highest PB concentrations in blood, gut, liver, spleen, brain, and white adipose tissues, with no significant increase in pancreas, heart, skeletal muscles, kidneys, urine or feces. Interferon gamma in plasma was significantly reduced by PB-UDCA suggesting potent anti-inflammatory effects. Blood glucose levels remained similar after treatments, while survival was highest among the PB-UDCA group. Our findings suggest that PB-UDCA resulted in best PB blood and tissue absorption and reduced inflammation.


Subject(s)
Anti-Inflammatory Agents/therapeutic use , Diabetes Mellitus, Experimental/drug therapy , Diabetes Mellitus, Type 1/drug therapy , Insulin-Secreting Cells/drug effects , Probucol/therapeutic use , Ursodeoxycholic Acid/therapeutic use , Animals , Anti-Inflammatory Agents/administration & dosage , Anti-Inflammatory Agents/pharmacokinetics , Drug Combinations , Drug Compounding , Excipients/chemistry , Mice, Inbred BALB C , Particle Size , Probucol/administration & dosage , Probucol/pharmacokinetics , Tissue Distribution , Ursodeoxycholic Acid/administration & dosage , Ursodeoxycholic Acid/pharmacokinetics
14.
Sensors (Basel) ; 15(5): 11454-64, 2015 May 18.
Article in English | MEDLINE | ID: mdl-25993519

ABSTRACT

This paper presents a passive LC wireless sensor for measuring temperature. The sensor is designed as a parallel connection of a spiral inductor and an interdigitated capacitor and it was fabricated in a conductive layer using LTCC (Low Temperature Co-fired Ceramic) technology. The inderdigitated capacitor electrodes were coated with a thin film of bismuth doped barium titanate (Ba0.9Bi0.066TiO3), whose permittivity changes with temperature, which directly induces changes in the capacitance of the interdigitated capacitor and consequently changes the resonant frequency of the sensor. The measurements of S-parameter of the sensor were performed using a Vector Network Analyzer (E5071B, Agilent Technologies, Santa Clara, CA, USA), whose port was connected to the antenna coil that was placed around the sensor in order to be able to wirelessly detect temperature, in the temperature range from 25 °C to 165 °C.

15.
Heliyon ; 10(4): e26069, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38420460

ABSTRACT

This work presents a novel approach towards integrating electronic components with textiles, by successfully creating a fully textile-based element that is capable of detecting applied forces by variation in its resistance value. The fabrication of the device consists of a specialized siliconized conductive fabric, which is placed above and below a layer of switch fabric, which acts as a force sensor. In this paper, the effects of three different geometries are observed, as well as the washability of the device, along with tension testing. Μoreover, the device behavior is simulated as well as applied in a real-life scenario. The proposed element demonstrates a good dynamic range, high repeatability and stability, and minimal impact of washing, creating a great candidate for integration in e-textiles.

16.
ACS Omega ; 9(6): 6527-6536, 2024 Feb 13.
Article in English | MEDLINE | ID: mdl-38371763

ABSTRACT

Tissue engineering is currently one of the fastest-growing areas of engineering, requiring the fabrication of advanced and multifunctional materials that can be used as scaffolds or dressings for tissue regeneration. In this work, we report a bilayer material prepared by electrospinning a hybrid material of poly(vinyl alcohol) (PVA) and bacterial cellulose (BC NFs) (top layer) over a highly interconnected porous 3D gelatin-PVA hydrogel obtained by a freeze-drying process (bottom layer). The techniques were combined to produce an advanced material with synergistic effects on the physical and biological properties of the two materials. The bilayer material was characterized using Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and a water contact measurement system (WCMS). Studies on swelling, degradability, porosity, drug release, cellular and antibacterial activities were performed using standardized procedures and assays. FTIR confirmed cross-linking of both the top and bottom layers, and SEM showed porous structure for the bottom layer, random deposition of NFs on the surface, and aligned NFs in the cross section. The water contact angle (WCA) showed a hydrophilic surface for the bilayer material. Swelling analysis showed high swelling, and degradation analysis showed good stability. The bilayer material released Ag-sulfadiazine in a sustained and controlled manner and showed good antibacterial activities against severe disease-causing gram + ive and -ive (Escherichia coli, Staphylococcus aureus, and Pseudomonas aeruginosa) bacterial strains. In vitro biological studies were performed on fibroblasts (3T3) and human embryonic kidneys (HEK-293), which showed desirable cell viability, proliferation, and adhesion to the bilayer. Thus, the synergistic effect of NFs and the hydrogel resulted in a potential wound dressing material for wound healing and soft tissue engineering.

17.
Int J Biol Macromol ; 254(Pt 3): 127882, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37951446

ABSTRACT

Tissue engineering is an advanced and potential biomedical approach to treat patients suffering from lost or failed an organ or tissue to repair and regenerate damaged tissues that increase life expectancy. The biopolymers have been used to fabricate smart hydrogels to repair damaged tissue as they imitate the extracellular matrix (ECM) with intricate structural and functional characteristics. These hydrogels offer desired and controllable qualities, such as tunable mechanical stiffness and strength, inherent adaptability and biocompatibility, swellability, and biodegradability, all crucial for tissue engineering. Smart hydrogels provide a superior cellular environment for tissue engineering, enabling the generation of cutting-edge synthetic tissues due to their special qualities, such as stimuli sensitivity and reactivity. Numerous review articles have presented the exceptional potential of hydrogels for various biomedical applications, including drug delivery, regenerative medicine, and tissue engineering. Still, it is essential to write a comprehensive review article on smart hydrogels that successfully addresses the essential challenging issues in tissue engineering. Hence, the recent development on smart hydrogel for state-of-the-art tissue engineering conferred progress, highlighting significant challenges and future perspectives. This review discusses recent advances in smart hydrogels fabricated from biological macromolecules and their use for advanced tissue engineering. It also provides critical insight, emphasizing future research directions and progress in tissue engineering.


Subject(s)
Hydrogels , Tissue Engineering , Humans , Hydrogels/chemistry , Regenerative Medicine , Extracellular Matrix/chemistry , Drug Delivery Systems
18.
ACS Omega ; 9(9): 10539-10555, 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38463280

ABSTRACT

Covarine, copper phthalocyanine, a novel tooth whitening ingredient, has been incorporated into various toothpaste formulations using diverse technologies such as larger flakes, two-phase pastes, and microbeads. In this study, we investigated the behavior of covarine microbeads (200 µm) in Colgate advanced white toothpaste when mixed with artificial and real saliva. Our analysis utilized a custom-designed microfluidic mixer with 400 µm wide channels arranged in serpentine patterns, featuring a Y-shaped design for saliva and toothpaste flow. The mixer, fabricated using stereolithography 3D printing technology, incorporated a flexible transparent resin (Formlabs' Flexible 80A resin) and PMMA layers. COMSOL simulations were performed by utilizing parameters extracted from toothpaste and saliva datasheets, supplemented by laboratory measurements, to enhance simulation accuracy. Experimental assessments encompassing the behavior of covarine particles were conducted using an optical profilometer. Viscosity tests and electrical impedance spectroscopy employing recently developed all-carbon electrodes were employed to analyze different toothpaste dilutions. The integration of experimental data from microfluidic chips with computational simulations offers thorough insights into the interactions of covarine particles with saliva and the formation of microfilms on enamel surfaces.

19.
Biomed Mater ; 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38976990

ABSTRACT

Wound healing is a critical but complex biological process of skin tissue repair and regeneration resulting from various systems working together at the cellular and molecular levels. Quick wound healing and the problems associated with traditional wound repair techniques are being overcome with multifunctional materials. Over time, this research area has drawn significant attention. Metal-organic frameworks (MOFs), owning to their peculiar physicochemical characteristics, are now considered a promising class of well-suited porous materials for wound healing in addition to their other biological applications. This detailed literature review provides an overview of the latest developments in MOFs for wound healing applications. We have discussed the synthesis, essential biomedical properties, wound-healing mechanism, MOF-based dressing materials, and their wound-healing applications. The possible major challenges and limitations of MOFs have been discussed, along with conclusions and future perspectives. This overview of the literature review addresses MOFs-based wound healing from several angles and covers the most current developments in the subject. The readers may discover how the MOFs advanced this discipline by producing more inventive, useful, and successful dressings. It influences the development of future generations of biomaterials for the healing and regeneration of skin wounds.

20.
Lab Chip ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38954466

ABSTRACT

Microfluidic devices with integrated membranes that enable control of mass transport in constrained environments have shown considerable growth over the last decade. Membranes are a key component in several industrial processes such as chemical, pharmaceutical, biotechnological, food, and metallurgy separation processes as well as waste management applications, allowing for modular and compact systems. Moreover, the miniaturization of a process through microfluidic devices leads to process intensification together with reagents, waste and cost reduction, and energy and space savings. The combination of membrane technology and microfluidic devices allows therefore magnification of their respective advantages, providing more valuable solutions not only for industrial processes but also for reproducing biological processes. This review focuses on membrane-based microfluidic devices for biomedical science with an emphasis on microfluidic artificial organs and organs-on-chip. We provide the basic concepts of membrane technology and the laws governing mass transport. The role of the membrane in biomedical microfluidic devices, along with the required properties, available materials, and current challenges are summarized. We believe that the present review may be a starting point and a resource for researchers who aim to replicate a biological phenomenon on-chip by applying membrane technology, for moving forward the biomedical applications.

SELECTION OF CITATIONS
SEARCH DETAIL