Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters

Database
Language
Journal subject
Affiliation country
Publication year range
1.
Phys Rev Lett ; 120(16): 164801, 2018 Apr 20.
Article in English | MEDLINE | ID: mdl-29756951

ABSTRACT

Photonic structures operating in the terahertz (THz) spectral region enable the essential characteristics of confinement, modal control, and electric field shielding for very high gradient accelerators based on wakefields in dielectrics. We report here an experimental investigation of THz wakefield modes in a three-dimensional photonic woodpile structure. Selective control in exciting or suppressing of wakefield modes with a nonzero transverse wave vector is demonstrated by using drive beams of varying transverse ellipticity. Additionally, we show that the wakefield spectrum is insensitive to the offset position of strongly elliptical beams. These results are consistent with analytic theory and three-dimensional simulations and illustrate a key advantage of wakefield systems with Cartesian symmetry: the suppression of transverse wakes by elliptical beams.

2.
Phys Rev Lett ; 120(11): 114802, 2018 Mar 16.
Article in English | MEDLINE | ID: mdl-29601767

ABSTRACT

We present results of an experiment showing the first successful demonstration of a cascaded microbunching scheme. Two modulator-chicane prebunchers arranged in series and a high power mid-IR laser seed are used to modulate a 52 MeV electron beam into a train of sharp microbunches phase locked to the external drive laser. This configuration is shown to greatly improve matching of the beam into the small longitudinal phase space acceptance of short-wavelength accelerators. We demonstrate trapping of nearly all (96%) of the electrons in a strongly tapered inverse free-electron laser accelerator, with an order-of-magnitude reduction in injection losses compared to the classical single-buncher scheme. These results represent a critical advance in laser-based longitudinal phase space manipulations and find application in high gradient advanced acceleration as well as in high peak and average power coherent radiation sources.

3.
Phys Rev Lett ; 117(17): 174801, 2016 Oct 21.
Article in English | MEDLINE | ID: mdl-27824445

ABSTRACT

We present results of an experiment where, using a 200 GW CO_{2} laser seed, a 65 MeV electron beam was decelerated down to 35 MeV in a 54-cm-long strongly tapered helical magnetic undulator, extracting over 30% of the initial electron beam energy to coherent radiation. These results, supported by simulations of the radiation field evolution, demonstrate unparalleled electro-optical conversion efficiencies for a relativistic beam in an undulator field and represent an important step in the development of high peak and average power coherent radiation sources.

4.
Sci Rep ; 9(1): 532, 2019 Jan 24.
Article in English | MEDLINE | ID: mdl-30679471

ABSTRACT

The generation of X-rays and γ-rays based on synchrotron radiation from free electrons, emitted in magnet arrays such as undulators, forms the basis of much of modern X-ray science. This approach has the drawback of requiring very high energy, up to the multi-GeV-scale, electron beams, to obtain the required photon energy. Due to the limit in accelerating gradients in conventional particle accelerators, reaching high energy typically demands use of instruments exceeding 100's of meters in length. Compact, less costly, monochromatic X-ray sources based on very high field acceleration and very short period undulators, however, may enable diverse, paradigm-changing X-ray applications ranging from novel X-ray therapy techniques to active interrogation of sensitive materials, by making them accessible in energy reach, cost and size. Such compactness and enhanced energy reach may be obtained by an all-optical approach, which employs a laser-driven high gradient accelerator based on inverse free electron laser (IFEL), followed by a collision point for inverse Compton scattering (ICS), a scheme where a laser is used to provide undulator fields. We present an experimental proof-of-principle of this approach, where a TW-class CO2 laser pulse is split in two, with half used to accelerate a high quality electron beam up to 84 MeV through the IFEL interaction, and the other half acts as an electromagnetic undulator to generate up to 13 keV X-rays via ICS. These results demonstrate the feasibility of this scheme, which can be joined with other techniques such as laser recirculation to yield very compact photon sources, with both high peak and average brilliance, and with energies extending from the keV to MeV scale. Further, use of the IFEL acceleration with the ICS interaction produces a train of high intensity X-ray pulses, thus enabling a unique tool synchronized with a laser pulse for ultra-fast strobe, pump-probe experimental scenarios.

5.
Res Microbiol ; 169(9): 500-504, 2018 Nov.
Article in English | MEDLINE | ID: mdl-29772256

ABSTRACT

Certain pleomorphic archaeal viruses are highly infectious even at saturated salt. These viruses belong to the genus Betapleolipovirus of the recently described archaeal virus family Pleolipoviridae. Pleolipoviruses comprise single-stranded or double-stranded, circular or linear DNA genomes that share countless homologues among various archaeal genetic elements. Here we describe a new extremely halophilic betapleolipovirus, Halorubrum pleomorphic virus 9 (HRPV9), which has an integrase gene. We also identified new genes encoding minor pleolipoviral structural proteins. The studies on HRPV9 enhance our knowledge on pleolipoviruses, especially their reciprocal relatedness and relation to certain archaeal plasmids, proviruses and membrane vesicles.


Subject(s)
Archaeal Viruses/enzymology , Archaeal Viruses/genetics , Integrases/genetics , Salinity , Archaeal Viruses/classification , Archaeal Viruses/physiology , DNA Viruses/genetics , DNA, Viral/genetics , Genome, Viral , Open Reading Frames , Plasmids , Virion
SELECTION OF CITATIONS
SEARCH DETAIL