Heart Vessels ; 39(1): 48-56, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37606754

ABSTRACT

The cusp overlap technique allows greater visual separation between the basal annular plane and the conduction system and decreases the permanent pacemaker implantation rate. We assessed the impact of the cusp overlap technique on conduction disturbance and paravalvular leakage after transcatheter aortic valve replacement. A total of 97 patients underwent transfemoral transcatheter aortic valve replacement with self-expandable valves at our institution from November 2018 to January 2023. The mean age of the patients was 85 years, and 23% were male. The patients were divided into two groups: the cusp overlap technique group and the non-cusp overlap technique group. We compared the clinical results between the two groups. The 30-day permanent pacemaker implantation rate was similar between the two groups (cusp overlap technique: 6.3% vs. non-cusp overlap technique: 10.2%, p = 0.48). The rate of new-onset conduction disturbance was slightly lower in the cusp overlap than non-cusp overlap technique group (18.8% vs. 34.7%, respectively; p = 0.08). The implanted valve function was similar between the two groups, but the rate of trivial or less paravalvular leakage (PVL) was significantly higher in the cusp overlap technique group on echocardiography (69% vs. 45%, p = 0.02). On multidetector computed tomography, the implantation depth at the membranous septum was significantly shorter in the cusp overlap technique group (2.0 ± 2.3 vs. 2.9 ± 1.5 mm, p = 0.02). The degree of canting was slightly smaller in the cusp overlap technique group (1.0 ± 2.2 vs. 1.7 ± 1.9 mm, p = 0.07). The relative risk of PVL equal to or greater than mild was 1.76 times higher for valve implantation without the cusp overlap technique (adjusted odds ratio, 3.74; 95% confidence interval, 1.45-9.69; p < 0.01). Transcatheter aortic valve replacement using the cusp overlap technique is associated with an optimized implantation depth, leading to fewer conduction disturbances. Optimal deployment may also maximize the radial force of self-expanding valves to reduce paravalvular leakage.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aged, 80 and over , Female , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Multidetector Computed Tomography , Cardiac Conduction System Disease , Treatment Outcome , Prosthesis Design
2.
J Artif Organs ; 25(1): 34-41, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34023940

ABSTRACT

The 25-mm Medtronic Mosaic porcine bioprosthesis (MB25) is the smallest bioprosthesis that has been approved for use in the mitral position in Japan. Various studies have reported satisfactory hemodynamic performance and good long-term outcomes of the Medtronic Mosaic porcine bioprosthesis. However, the hemodynamic and clinical performances of the MB25 in the mitral position remain unknown. This study aimed to evaluate the hemodynamic and clinical performance of the MB25 in mitral valve replacement (MVR). Twenty patients who underwent MVR using the MB25 between February 2013 and April 2018 were studied. We evaluated the hemodynamic performance of the MB25, cardiac chamber size, cardiac function, and systolic pulmonary artery pressure (PAP) using echocardiography during follow-up. The study outcomes were major adverse cardiac events (MACEs) and all-cause mortality. Sixteen patients (80%) had a patient prosthesis mismatch defined as an index effective orifice area of ≤ 1.2 cm2/m2. The left atrial dimension was significantly reduced after surgery (p = 0.0282). The mean pressure gradients (MPG) in the mitral position were 5.5 ± 1.7 mmHg at discharge and 4.2 ± 1.3 mmHg at 1 year postoperatively. The MPG in the mitral position significantly decreased during the follow-up period (p = 0.0489). Systolic PAP significantly improved postoperatively. The 1-, 3-, and 5-year survival rates were 87, 79, and 70%, respectively. No cardiac death occurred. There were no MACEs or reports of structural valve degeneration during the follow-up period. The hemodynamic and clinical performances of the MB25 in the mitral position were satisfactory as the smallest biological mitral valve. The MB25 is a reasonable option for MVR to reduce the surgical difficulty in high-risk patients with an advanced age, a small body size or MAC and when recurrent MVR or complex procedures are performed.


Subject(s)
Bioprosthesis , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Animals , Aortic Valve/surgery , Follow-Up Studies , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/methods , Hemodynamics , Humans , Postoperative Complications/surgery , Prosthesis Design , Swine
3.
J Card Surg ; 37(11): 3928-3931, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36040457

ABSTRACT

Modern multi-slice computed tomography (CT) has increased the detection of hypo-attenuated leaflet thickening (HALT). Furthermore, HALT's impact on transcatheter or surgical biological aortic valve (AV) prostheses has attracted attention. However, few reports on HALT in sutureless bioprostheses exist. Herein, we report a case of early structural valve deterioration due to HALT after AV replacement (AVR) with a Perceval bioprosthesis, which improved after anticoagulation therapy. A 79-year-old man admitted to our hospital with paroxysmal atrial fibrillation (PAF) during hemodialysis was also diagnosed with AV stenosis and, coronary artery disease, and PAF. He underwent AVR, coronary artery bypass grafting, and left atrial appendage resection. Although the postoperative course was uneventful with dual antiplatelet therapy, postoperative enhanced CT revealed HALT with reduced leaflet motion, and echocardiography showed an increased transvalvular pressure gradient. After using warfarin with target prothrombin time-international normalized ratio of 2-2.5 and/or heparin with target activated partial thromboplastin time of 45-60 s, the HALT disappeared with an improved transvalvular pressure gradient without any thromboembolic events.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Anticoagulants/therapeutic use , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Heparin , Humans , Male , Platelet Aggregation Inhibitors , Prosthesis Design , Treatment Outcome , Warfarin
4.
Heart Vessels ; 36(8): 1256-1263, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33586008

ABSTRACT

Aortic stenosis (AS) is the most common valve disorder in advanced age. Previous reports have shown that low-flow status of the left ventricle is an independent predictor of cardiovascular mortality after surgery. The Trifecta bioprosthesis has recently shown favorable hemodynamic performance. This study aimed to evaluate the effect of the Trifecta bioprosthesis, which has a large effective orifice area, in patients with low-flow severe AS who have a poor prognosis. We retrospectively evaluated 94 consecutive patients with severe AS who underwent aortic valve replacement (AVR). Patients were divided into two groups according to the stroke volume index (SVI): low-flow (LF) group (SVI < 35 ml/m2, n = 22) and normal-flow (NF) group (SVI ≥ 35 ml/m2, n = 72). Patients' characteristics and early and mid-term results were compared between the two groups. There were no differences in patients' characteristics, except for systolic blood pressure (LF:NF = 120:138 mmHg, p < 0.01) and the rate of atrial fibrillation between the groups. A preoperative echocardiogram showed that the pressure gradient was higher in the NF group than in the LF group, but aortic valve area was similar. The Trifecta bioprosthesis size was similar in both groups. The operative outcomes were not different between the groups. Severe patient-prosthesis mismatch (PPM) (< 0.65 cm2/m2) was not observed in either of the groups. There were no significant differences in mid-term results between the two groups. The favorable hemodynamic performance of the Trifecta bioprosthesis appears to have the similar outcomes in the LF and NF groups. AVR with the Trifecta bioprosthesis should be considered for avoidance of PPM, particularly in AS patients with LV dysfunction.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Hemodynamics , Humans , Prosthesis Design , Retrospective Studies , Treatment Outcome
5.
J Artif Organs ; 24(4): 458-464, 2021 Dec.
Article in English | MEDLINE | ID: mdl-33770272

ABSTRACT

To assess the early hemodynamics after mitral valve replacement (MVR) using the St Jude Medical (SJM) Epic bioprosthesis. MVR was performed using the SJM Epic bioprosthesis in 35 patients from June 2018 to April 2020; three patients were excluded because the postoperative transthoracic echocardiography (TTE) data were unavailable. Data from postoperative TTE at 1 week and 3 months after the procedure were reviewed. The mean mitral pressure gradient (mMPG) was calculated using a continuous wave Doppler method. Left ventricular outflow tract (LVOT) was calculated using a pulse wave Doppler method. The effective orifice area (EOA) was measured from pressure half time. There were 12 men (37.5%) and 20 women (62.5%) with a mean age of 75.9 years (61-88 years). The mean body surface area was 1.51 ± 0.22 cm2. The 25 mm and 27 mm valves were used in more than 50% of cases. The mMPG was 4.9 ± 1.7 mmHg and 5.4 ± 1.6 mmHg at 1 week and 3 months after surgery, respectively. EOA was 2.18 ± 0.50 cm2 and 2.31 ± 0.59 cm2 at 1 week and 3 months after surgery, respectively. The peak velocity of the LVOT (n = 22) was 103.3 ± 21.3 cm/s and 106.8 ± 27.4 cm/s at 1 week and 3 months after surgery, respectively. No findings suggested paravalvular regurgitation and LVOT obstruction. Using the SJM Epic bioprosthesis in MVR resulted in satisfactory hemodynamics in the early postoperative period, even with small valve sizes. Further accumulation of cases and evidence, including mid- to long-term results, is required in the future.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aged , Aortic Valve , Female , Hemodynamics , Humans , Japan , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Prosthesis Design
6.
Surg Today ; 51(9): 1456-1463, 2021 Sep.
Article in English | MEDLINE | ID: mdl-33555435

ABSTRACT

PURPOSE: Hepatocellular carcinoma (HCC) is one of the most common primary cancers worldwide. HCC has unique characteristics such as co-existing chronic liver damage and a high recurrence rate. A negative impact on the surgical outcome due to these backgrounds could be expected. We aimed to evaluate the clinical outcomes of cardiac surgery in these patients. METHODS: Between January 2000 and December 2019, 16 patients with remitted cancer and 5 patients with active HCC who underwent open heart surgery were studied. The clinical data were retrospectively evaluated from hospital records. Follow-up information was collected via telephone interviews. RESULTS: The major cause of HCC was viral hepatitis. Eighteen patients (86%) were classified as having Child-Pugh class A cirrhosis. The mean model of end-stage liver disease (MELD) score was 7.2 ± 5.2. There was no 30-day mortality. During follow-up, 11 patients died due to HCC. The 1-, 3-, and 5-year survival rates were 80.0, 42.5, and 22.3%, respectively. A univariate analysis identified a higher preoperative MELD score and lower serum cholinesterase levels as prognostic factors for long-term survival. CONCLUSION: We could safely perform cardiac surgery in selected patients with remitted and active HCC. The postoperative life expectancy of these patients was limited but acceptable.


Subject(s)
Carcinoma, Hepatocellular/complications , Heart Diseases/surgery , Liver Neoplasms/complications , Aged , Aged, 80 and over , Cardiac Surgical Procedures/methods , Female , Follow-Up Studies , Heart Diseases/complications , Humans , Life Expectancy , Male , Middle Aged , Retrospective Studies , Time Factors , Treatment Outcome
7.
J Nucl Cardiol ; 27(2): 682-685, 2020 04.
Article in English | MEDLINE | ID: mdl-30421382

ABSTRACT

Cardiac-calcified amorphous tumor (CAT) is a rare non-neoplastic tumor and its origin and pathogenesis are still unclear. In addition, it is difficult to clinically diagnose as cardiac CAT without pathological findings. We present a case of a 78-year-male diagnosed with cardiac CAT after surgical resection. We could evaluate tumor aspects by multimodal imaging including echocardiography, contrast-enhanced computed tomography (CT), magnetic resonance image, and 18F-fluorodeoxyglucose-positron emission tomography/CT before surgery.


Subject(s)
Contrast Media , Echocardiography/methods , Fluorodeoxyglucose F18 , Heart Neoplasms/diagnostic imaging , Heart/diagnostic imaging , Multimodal Imaging/methods , Neoplasms/diagnostic imaging , Positron Emission Tomography Computed Tomography/methods , Tomography, X-Ray Computed/methods , Aged , Humans , Inflammation , Magnetic Resonance Imaging/methods , Male , Positron-Emission Tomography/methods
8.
Heart Vessels ; 35(10): 1409-1418, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32394242

ABSTRACT

Degenerative aortic stenosis is the most common structural heart valve disease affecting the aging population. Catheter-based heart valve interventions are less invasive and very useful for very elderly patients. However, we often consider open heart surgery for these patients because of anatomical reasons and co-existing cardiac diseases, i.e., severe coronary artery disease. We aimed to analyze the outcomes of very elderly patients aged ≥ 85 years undergoing aortic valve replacement (AVR) with or without coronary artery bypass grafting (CABG). Twenty-nine very elderly patients aged ≥ 85 years who underwent AVR with CABG (n = 11, Group AC) or isolated AVR (n = 18, Group A) were examined. The overall mean age of the patients was 87.2 ± 2.6 (range 85-94) years. The estimated operative mortality rate, calculated using the Japan score, EuroSCORE II, and STS risk score, was 5.72%-10.88% in Group AC and 5.63%-8.30% in Group A. Aortic cross-clamp time (126.5 ± 29.0 vs. 96.9 ± 29.2 min, p = 0.016) was significantly longer in Group AC than in Group A. Although the major morbidity rate was higher in Group AC than in Group A (36% vs. 6%, p = 0.0336), the length of intensive care unit stay and hospital stay was comparable between both groups. There was no 30-day and hospital mortality in both groups. Eleven patients died during follow-up (senility, 5; cerebrovascular events, 2; renal failure, 1; unknown, 3). There were no significant differences in survival rates during follow-up (log-rank p value = 0.1051). The 1-, 2-, 3-, 4- and 5-year survival rates were 91%, 80%, 69%, 69% and 69%, respectively, in Group AC and 94%, 94%, 94%, 94% and 88%, respectively, in Group A. In conclusion, AVR with or without CABG could be safely performed in carefully selected very elderly patients with acceptable early- and long-term results. AVR with CABG in very elderly patients aged ≥ 85 offers similar results to isolated AVR in terms of 30-day mortality, hospital mortality, and long-term survival.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Coronary Artery Bypass , Coronary Artery Disease/surgery , Heart Valve Prosthesis Implantation , Age Factors , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass/mortality , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Hospital Mortality , Humans , Length of Stay , Male , Operative Time , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
9.
J Card Surg ; 35(1): 246-249, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31710735

ABSTRACT

We report an 83-year-old man with a mycotic left ventricular apical pseudoaneurysm and aortic prosthetic valve endocarditis caused by Enterococcus spp. Mycotic left ventricular pseudoaneurysm is very rare and is associated with a high risk of rupture. Here, we report the clinical presentation, diagnosis, prognosis, and treatment of a case of mycotic left ventricular pseudoaneurysm to raise awareness regarding this unusual and potentially fatal complication.


Subject(s)
Aortic Valve/surgery , Coronary Aneurysm/surgery , Endocarditis/surgery , Heart Ventricles/surgery , Prosthesis-Related Infections/surgery , Aged, 80 and over , Endocarditis/microbiology , Enterococcus , Humans , Male , Prosthesis-Related Infections/microbiology , Treatment Outcome
11.
Circ J ; 82(10): 2485-2492, 2018 09 25.
Article in English | MEDLINE | ID: mdl-30089758

ABSTRACT

BACKGROUND: Dilatation of the ascending aorta affects those patients with bicuspid aortic valve (BAV), even after valvular surgery, possibly due to tissue fragility. The goal of the study was the molecular characterization of aorta with BAV compared to that with normal tricuspid aortic valve (TAV). Methods and Results: The subjects were patients who underwent surgery for aortic valve stenosis in 2013 and 2014. Nine patients with BAV and 13 with TAV were examined. There was no difference in the clinical characteristics or grade of aortic valve stenosis, but the diameters of the ascending aorta were significantly higher in the BAV group. The ascending aortic specimens were subjected to transcriptome analyses, which revealed the changes in receptor tyrosine kinase (RTK) pathway-related genes between TAV and BAV samples. Immunohistochemical study revealed higher staining of phosphorylated AKT (pAKT) in the media of the ascending aorta in the BAV group, regardless of the size of ascending aorta, whereas total AKT did not show such a difference. Immunofluorescence staining revealed the AKT activation was mainly in the medial vascular smooth muscle cells. CONCLUSIONS: The results showed that the RTK-AKT pathway in the medial layer of the ascending aorta is activated in aortae with BAV. Activation of this pathway may be associated with fragility and dilatation of the ascending aorta with BAV.


Subject(s)
Aorta/metabolism , Aortic Valve Insufficiency/surgery , Aortic Valve/abnormalities , Heart Valve Diseases/metabolism , Proto-Oncogene Proteins c-akt/metabolism , Signal Transduction , Aged , Aged, 80 and over , Aorta/anatomy & histology , Aorta/pathology , Aorta/surgery , Aortic Valve/metabolism , Bicuspid Aortic Valve Disease , Dilatation, Pathologic , Female , Gene Expression Profiling , Humans , Immunohistochemistry , Male
12.
J Heart Valve Dis ; 25(4): 437-439, 2016 07.
Article in English | MEDLINE | ID: mdl-28009946

ABSTRACT

A 70-year-old woman with a history of aortic valve replacement and coronary artery bypass grafting (CABG) was transferred to the authors' hospital for further management of a three-month fever of unknown origin. Computed tomography showed a huge mass in the ascending aorta with pseudoaneurysm. Blood ß-D-glucan levels were significantly high, and blood culture showed the growth of Candida albicans. The fungus ball was excised surgically, together with aortic root replacement and CABG, followed by six-month postoperative anti-fungal therapy. Early diagnosis by imaging studies followed by aggressive surgery and long-term postoperative antifungal treatment should result in a favorable outcome.


Subject(s)
Aneurysm, False/microbiology , Aneurysm, False/surgery , Aorta/microbiology , Aorta/surgery , Candida albicans/isolation & purification , Candidiasis/diagnosis , Candidiasis/surgery , Aged , Aortic Valve Stenosis/surgery , Coronary Artery Bypass , Female , Heart Valve Prosthesis Implantation , Humans
14.
Artif Organs ; 38(5): 374-82, 2014 May.
Article in English | MEDLINE | ID: mdl-24118024

ABSTRACT

The PediPump was implanted in six healthy lambs (mean 25.6 ± 1.4 kg) between the left ventricular apex and the descending aorta to evaluate in vivo performance for up to 30 days. Anticoagulation was achieved by continuous heparin infusion. Three animals were euthanized prematurely, two because of respiratory dysfunction and one because of deteriorating pump performance resulting from thrombus formation inside the pump. Three lambs were electively sacrificed 30 days after implantation; all had stable hemodynamics and minimal hemolysis, as indicated by low plasma free hemoglobin (2.5 ± 3.1 mg/dL). Mean 30-day pump flow was 1.8 ± 0.1 L/min at a pump speed of 12 200 ± 400 rpm. Neither activated clotting time nor activated partial thromboplastin time followed the changes in heparin dose. At necropsy, depositions were observed at the front (n = 1) and rear rotor axial positioning stops (n = 4); improved polishing techniques on the stationary stop surfaces and the addition of a hard-carbon, thin-film coating on the rotating stop of the pumps used for the last two experiments addressed the deposition seen earlier. In conclusion, the PediPump showed excellent hydraulic performance and minimal hemolysis during support for up to 30 days. Depositions observed at the axial positioning stops in earlier experiments were addressed by design and material refinements. We continue to focus on developing effective anticoagulation management in the lamb model as well as on further evaluating and demonstrating pump biocompatibility.


Subject(s)
Heart Defects, Congenital/surgery , Heart Ventricles/surgery , Heart-Assist Devices , Animals , Anticoagulants/therapeutic use , Heart Defects, Congenital/blood , Heart Defects, Congenital/physiopathology , Heart Ventricles/physiopathology , Heart-Assist Devices/adverse effects , Hemodynamics , Prosthesis Design , Sheep
15.
Kurume Med J ; 2024 Sep 06.
Article in English | MEDLINE | ID: mdl-39245570

ABSTRACT

Due to bicuspid aortic valve aortic stenosis, a 78-year-old man with a history of esophagectomy and presternal gastric tube reconstruction required aortic valve replacement (AVR). AVR with a bioprosthetic valve was performed through a right parasternal thoracotomy. Despite the unfavorable conditions for conventional median sternotomy, AVR was successfully performed through an alternate approach. The right parasternal approach was excellent for AVR in patients with presternal gastric tube reconstruction for esophageal cancer (EC).

16.
Kurume Med J ; 2024 Sep 02.
Article in English | MEDLINE | ID: mdl-39218645

ABSTRACT

BACKGROUND: Although recent studies have revealed the importance of inflammation in the pathogenesis of aortic dissection (AD), little is known about the relationships among inflammatory cells in human AD tissue. METHODS AND RESULTS: We assessed the relationships among various immune cell types, including neutrophils, macrophages (M1 and M2), B cells, and helper T cells (Th1, Th2, Th17, Treg and Tfh ) in human AD tissue. AD tissues displayed abundant infiltration of immune cells. Correlation analysis revealed two groups of highly correlated cell types: a group of neutrophils and M1 and M2 macrophages, and another group consisting of B cells and helper T cells. In one particular case of AD, we were able to analyze the correlations between neutrophils and M1 and M2 macrophages in the entry, border, and intact zones of the AD lesions. Neutrophils showed significant correlations with M1 and M2 macrophages in the border zones. The entry and border zones showed M1-dominant polarization, whereas the intact zone showed M2-dominant polarization. CONCLUSIONS: These findings indicate the existence of cell type-specific and site-specific interactions among immune cell types in human AD tissues.

17.
Gen Thorac Cardiovasc Surg ; 72(9): 568-576, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38403822

ABSTRACT

OBJECTIVE: To assess the occurrence, predictors, and outcomes of hypo-attenuated leaflet thickening (HALT) and thrombus outside the prosthetic valve following surgical aortic valve replacement. METHODS: A total of 118 patients underwent surgical aortic valve replacement with bioprosthetic valves between July 2020 and June 2022. Sixty-two (52.5%) patients, which is a fairly high number of patients, underwent cardiac computed tomography and transthoracic echocardiography one week after surgery. Patients were divided into two groups, those with HALT (n = 14) and those without HALT (n = 48). RESULTS: Of the 62 patients who underwent cardiac computed tomography, HALT was observed in 14 (22.5%) patients during the very early postoperative phase. Reduced leaflet motion was observed in two of the 14 patients. The low-attenuation areas were located outside the prosthetic valve in 10 cases (71.4%) in the HALT group and in 14 cases (29.2%) in the non-HALT group. More than 50% of patients (57.1%) with HALT and 79.2% without HALT were administered warfarin. Neither in-hospital deaths nor postoperative thromboembolic events were observed during hospitalization. No patient had a mean pressure gradient > 20 mmHg in either group. CONCLUSION: HALT was observed in one-fifth of the cases after surgical aortic valve replacement during the very early postoperative phase in an institution wherein administration of continuous heparin infusion after surgery is a standard practice. HALT did not affect the early prognosis or incidence of cerebral infarction.


Subject(s)
Aortic Valve , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Thrombosis , Humans , Female , Male , Bioprosthesis/adverse effects , Aged , Thrombosis/etiology , Heart Valve Prosthesis/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Middle Aged , Retrospective Studies , Anticoagulants/therapeutic use , Anticoagulants/administration & dosage , Aged, 80 and over , Time Factors , Treatment Outcome , Risk Factors , Echocardiography , Aortic Valve Stenosis/surgery , Prosthesis Design
18.
J Thorac Dis ; 16(1): 333-343, 2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38410614

ABSTRACT

Background: Mitral valve repair (MVr) is an established procedure for patients who require surgery for primary mitral regurgitation (PMR). The Colvin-Galloway Future Band (CGFB) is a semi-rigid posterior band expected to improve the clinical outcomes of MVr. However, information on the hemodynamic and functional performance and long-term outcomes of CGFB is limited. We evaluated the quality, durability, and clinical performance after MVr using CGFB for PMR as the cohort study. Methods: A total of 244 patients who underwent MVr with CGFB were enrolled. Clinical and echocardiographic assessments were performed (mean follow-up period, 4.0±2.4 years). Results: Posterior mitral leaflet resection was the most common MVr procedure. CGFBs measuring 28 mm (35.2%) and 30 mm (36.5%) were used. The incidence of systolic anterior motion (SAM) was 1.6%. A total of 93.4% of the patients had no or trace MR at discharge. Over 90% of patients had no or mild MR at the last follow-up. The mean pressure gradient and mitral valve orifice area one year after MVr ranged between 2.6 and 3.6 mmHg and 2.3 and 3.4 cm2, respectively. At follow-up, 85.4% of the patients were New York Heart Association class I. Three patients underwent repeat mitral valve surgery. Conclusions: The CGFB demonstrates satisfactory quality and durability in MVr for PMR. Other advantages include a low occurrence of SAM and acceptable hemodynamic outcomes, particularly in patients requiring a smaller annuloplasty device.

19.
Oxf Med Case Reports ; 2024(7): omae065, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38989505

ABSTRACT

This report discusses a rare case of delayed migration of a Sapien 3 Ultra Resilia (S3UR) valve following transcatheter aortic valve implantation. An 81-year-old Japanese woman had a borderline aortic annular size of 20-23 mm according to the manufacturer's size chart. We chose to implant a smaller S3UR of 20 mm with an 80/20 depth ratio to allow for a second intervention, ensuring good hemodynamics and minimizing paravalvular leak. The patient initially had a favorable outcome despite an accidental 50/50 depth ratio during implantation. On postoperative day 3, the S3UR migrated into the left ventricular outflow tract. Emergency surgical aortic valve replacement was performed to retrieve the migrated valve. Use of the S3UR has led to a growing preference for smaller valve sizes. However, the risk of migration should be recognized. When an accidental 50/50 depth ratio implantation is encountered, post-dilation or second valve implantation should be performed immediately.