Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Breast Imaging ; 5(5): 565-574, 2023 Sep 22.
Article in English | MEDLINE | ID: mdl-38416917

ABSTRACT

OBJECTIVE: To assess use of mammography information systems (MISs) and explore features associated with breast imaging radiologist satisfaction. METHODS: A 22-question survey regarding MISs was distributed electronically to the Society of Breast Imaging membership between February 16, 2022 and June 28, 2022. Differences in responses between respondents satisfied and dissatisfied with their MIS were analyzed using Pearson chi-squared test, Fisher exact test, and multivariate logistic regression. RESULTS: The response rate was 11.4% (228/2007). Most respondents used a commercial MIS (195/228, 85.5%). Most used were Epic (47/228, 21%), MagView (47/228, 21%), and PenRad (37/228, 16%). Only 4.4% (10/228) reported that patient tracking was not integrated with results reporting. The majority (129/226, 57%) reported satisfaction with their MIS. Satisfaction correlated (P < 0.05) with features such as picture archiving and communication system integration, structured reporting, access to physician outcomes metrics, and ability to query data. Less commonly reported features such as non-English language options and recognition of laterality and patient mismatch errors also correlated with satisfaction. Lack of these features correlated with dissatisfaction (P < 0.05). Satisfaction also correlated with adequate training (P < 0.001) and technology support (P < 0.001). On multivariate analysis, longer time using the current MIS was independently associated with satisfaction. CONCLUSION: Most respondents used a commercial MIS and were satisfied with their system. Satisfied users reported several helpful MIS features and adequate training and support. The survey results could help MIS companies when designing new products and inform radiologists and administrators when considering a new MIS.


Subject(s)
Radiologists , Radiology Information Systems , Humans , Surveys and Questionnaires , Mammography , Information Systems
2.
Plast Reconstr Surg ; 145(2): 555-563, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31985658

ABSTRACT

BACKGROUND: Fat accumulation is frequently observed in patients with lymphedema but is not accounted for in existing staging systems. In addition, the specific regional patterns of fat and fluid accumulation remain unknown and might affect outcomes following medical or surgical intervention. The purpose of this study was to evaluate fluid and fat distribution in patients with lower extremity lymphedema using magnetic resonance angiography. METHODS: Magnetic resonance angiographic examinations of patients with lower extremity lymphedema were reviewed. Fluid-fat grade and location were assessed by three observers. Three-point scales were developed to grade fluid (0 = no fluid, 1 = reticular pattern of fluid, and 2 = continuous stripe of subcutaneous fluid) and fat (0 = normal, 1 = subcutaneous thickness less than twice that of the unaffected side, and 2 = subcutaneous thickness greater than twice that of the unaffected side) accumulation. RESULTS: In total, 76 magnetic resonance angiographic examinations were evaluated. Using the proposed grading system, there was good interobserver agreement for fat and fluid accumulation location (91.5 percent; κ = 0.9), fluid accumulation grade (95.7 percent; κ = 0.95), and fat accumulation grade (87.2 percent; κ = 0.86). Patients with International Society of Lymphology stage 2 lymphedema had a wide range of fluid and fat grades (normal to severe). The most common location of fluid accumulation was the lateral lower leg, whereas the most common location of fat accumulation was the medial and lateral lower leg. CONCLUSION: The proposed magnetic resonance angiographic grading system may help stratify patients with International Society of Lymphology stage 2 lymphedema on the basis of tissue composition. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, IV.


Subject(s)
Body Fluids , Leg/pathology , Lymphedema/pathology , Subcutaneous Fat/pathology , Adolescent , Adult , Aged , Body Fat Distribution , Child , Female , Humans , Magnetic Resonance Angiography , Male , Middle Aged , Observer Variation , Prospective Studies , Retrospective Studies , Young Adult
3.
Clin Imaging ; 55: 196-212, 2019.
Article in English | MEDLINE | ID: mdl-31204189

ABSTRACT

Tissue marker placement after image-guided breast biopsy has become a routine component of clinical practice. Marker placement distinguishes multiple biopsied lesions within the same breast, prevents re-biopsy of benign lesions, enables multi-modality correlation, guides pre-operative localization and helps confirm surgical target removal. Numerous breast tissue markers are currently available, with varied shapes, composition, and associated bio-absorbable components. This review serves to familiarize the breast interventionalist with the tissue markers most widely available in the United States today and to provide guidance regarding selection of appropriate markers for various clinical settings.

4.
Curr Radiol Rep ; 6(2): 5, 2018.
Article in English | MEDLINE | ID: mdl-29399419

ABSTRACT

PURPOSE OF REVIEW: Probably benign (BI-RADS 3) causes confusion for interpreting physicians and referring physicians and can induce significant patient anxiety. The best uses and evidence for using this assessment category in mammography, breast ultrasound, and breast MRI will be reviewed; the reader will have a better understanding of how and when to use BI-RADS 3. RECENT FINDINGS: Interobserver variability in the use of BI-RADS 3 has been documented. The 5th edition of the BI-RADS atlas details the appropriate use of BI-RADS 3 for diagnostic mammography, ultrasound, and MRI, and discourages its use in screening mammography. Data mining, elastography, and diffusion weighted MRI have been evaluated to maximize the accuracy of BI-RADS 3. SUMMARY: BI-RADS 3 is an evolving assessment category. When used properly, it reduces the number of benign biopsies while allowing the breast imager to maintain a high sensitivity for the detection of early stage breast cancer.

5.
Clin Imaging ; 52: 123-136, 2018.
Article in English | MEDLINE | ID: mdl-30059952

ABSTRACT

Tissue marker placement after image-guided breast biopsy has become a routine component of clinical practice. Marker placement distinguishes multiple biopsied lesions within the same breast, prevents re-biopsy of benign lesions, enables multi-modality correlation, guides pre-operative localization and helps confirm surgical target removal. Numerous breast tissue markers are currently available, with varied shapes, composition, and associated bio-absorbable components. This review serves to familiarize the breast interventionalist with the tissue markers most widely available in the United States today and to provide guidance regarding selection of appropriate markers for various clinical settings.


Subject(s)
Breast Neoplasms/pathology , Breast/pathology , Biopsy/methods , Female , Humans
SELECTION OF CITATIONS
SEARCH DETAIL