Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Circulation ; 147(5): 409-424, 2023 01 31.
Article in English | MEDLINE | ID: mdl-36448446

ABSTRACT

BACKGROUND: Extensive evidence from single-center studies indicates that a subset of patients with chronic advanced heart failure (HF) undergoing left ventricular assist device (LVAD) support show significantly improved heart function and reverse structural remodeling (ie, termed "responders"). Furthermore, we recently published a multicenter prospective study, RESTAGE-HF (Remission from Stage D Heart Failure), demonstrating that LVAD support combined with standard HF medications induced remarkable cardiac structural and functional improvement, leading to high rates of LVAD weaning and excellent long-term outcomes. This intriguing phenomenon provides great translational and clinical promise, although the underlying molecular mechanisms driving this recovery are largely unknown. METHODS: To identify changes in signaling pathways operative in the normal and failing human heart and to molecularly characterize patients who respond favorably to LVAD unloading, we performed global RNA sequencing and phosphopeptide profiling of left ventricular tissue from 93 patients with HF undergoing LVAD implantation (25 responders and 68 nonresponders) and 12 nonfailing donor hearts. Patients were prospectively monitored through echocardiography to characterize their myocardial structure and function and identify responders and nonresponders. RESULTS: These analyses identified 1341 transcripts and 288 phosphopeptides that are differentially regulated in cardiac tissue from nonfailing control samples and patients with HF. In addition, these unbiased molecular profiles identified a unique signature of 29 transcripts and 93 phosphopeptides in patients with HF that distinguished responders after LVAD unloading. Further analyses of these macromolecules highlighted differential regulation in 2 key pathways: cell cycle regulation and extracellular matrix/focal adhesions. CONCLUSIONS: This is the first study to characterize changes in the nonfailing and failing human heart by integrating multiple -omics platforms to identify molecular indices defining patients capable of myocardial recovery. These findings may guide patient selection for advanced HF therapies and identify new HF therapeutic targets.


Subject(s)
Heart Failure , Heart Transplantation , Heart-Assist Devices , Humans , Transcriptome , Prospective Studies , Phosphopeptides/metabolism , Proteomics , Tissue Donors , Heart Failure/genetics , Heart Failure/therapy , Heart Failure/metabolism , Myocardium/metabolism
2.
J Card Fail ; 2024 Sep 18.
Article in English | MEDLINE | ID: mdl-39299541

ABSTRACT

BACKGROUND: Optimal management of outpatients with heart failure (HF) requires serially updating the estimates of their risk for adverse clinical outcomes to guide treatment. Patient-reported outcomes (PROs) are becoming increasingly used in clinical care. The purpose of this study was to determine whether the inclusion of PROs can improve the risk prediction for HF hospitalization and death in ambulatory patients with HF. METHODS AND RESULTS: We included consecutive patients with HF with reduced ejection fraction (HFrEF) and HF with preserved EF (HFpEF) seen in a HF clinic between 2015 and 2019 who completed PROs as part of routine care. Cox regression with a least absolute shrinkage and selection operator regularization and gradient boosting machine analyses were used to estimate risk for a combined outcome of HF hospitalization, heart transplant, left ventricular assist device implantation, or death. The performance of the prediction models was evaluated with the time-dependent concordance index (Cτ). Among 1165 patients with HFrEF (mean age 59.1 ± 16.1, 68% male), the median follow-up was 487 days. Among 456 patients with HFpEF (mean age 64.2 ± 16.0 years, 55% male) the median follow-up was 494 days. Gradient boosting regression that included PROs had the best prediction performance - Cτ 0.73 for patients with HFrEF and 0.74 in patients with HFpEF, and showed very good stratification of risk by time to event analysis by quintile of risk. The Kansas City Cardiomyopathy Questionnaire overall summary score, visual analogue scale and Patient Reported Outcomes Measurement Information System dimensions of satisfaction with social roles and physical function had high variable importance measure in the models. CONCLUSIONS: PROs improve risk prediction in both HFrEF and HFpEF, independent of traditional clinical factors. Routine assessment of PROs and leveraging the comprehensive data in the electronic health record in routine clinical care could help more accurately assess risk and support the intensification of treatment in patients with HF.

3.
Clin Transplant ; 38(5): e15330, 2024 May.
Article in English | MEDLINE | ID: mdl-38716787

ABSTRACT

INTRODUCTION: Since the 2018 change in the US adult heart allocation policy, more patients are bridged-to-transplant on temporary mechanical circulatory support (tMCS). Previous studies indicate that durable left ventricular assist devices (LVAD) may lead to allosensitization. The goal of this study was to assess whether tMCS implantation is associated with changes in sensitization. METHODS: We included patients evaluated for heart transplants between 2015 and 2022 who had alloantibody measured before and after MCS implantation. Allosensitization was defined as development of new alloantibodies after tMCS implant. RESULTS: A total of 41 patients received tMCS before transplant. Nine (22.0%) patients developed alloantibodies following tMCS implantation: 3 (12.0%) in the intra-aortic balloon pump group (n = 25), 2 (28.6%) in the microaxial percutaneous LVAD group (n = 7), and 4 (44.4%) in the veno-arterial extra-corporeal membrane oxygenation group (n = 9)-p = .039. Sensitized patients were younger (44.7 ± 11.6 years vs. 54.3 ± 12.5 years, p = .044), were more likely to be sensitized at baseline - 3 of 9 (33.3%) compared to 2 out of 32 (6.3%) (p = .028) and received more transfusions with red blood cells (6 (66.6%) vs. 8 (25%), p = .02) and platelets (6 (66.6%) vs. 5 (15.6%), p = .002). There was no significant difference in tMCS median duration of support (4 [3,15] days vs. 8.5 [5,14.5] days, p = .57). Importantly, out of the 11 patients who received a durable LVAD after tMCS, 5 (45.5%) became sensitized, compared to 4 out of 30 patients (13.3%) who only had tMCS-p = .028. CONCLUSIONS: Our findings suggest that patients bridged-to-transplant with tMCS, without significant blood product transfusions and a subsequent durable LVAD implant, have a low risk of allosensitization. Further studies are needed to confirm our findings and determine whether risk of sensitization varies by type of tMCS and duration of support.


Subject(s)
Heart Transplantation , Heart-Assist Devices , Isoantibodies , Humans , Male , Female , Middle Aged , Isoantibodies/immunology , Isoantibodies/blood , Follow-Up Studies , Adult , Risk Factors , Prognosis , Retrospective Studies , Heart Failure/surgery , Heart Failure/therapy , Graft Rejection/etiology
4.
Circulation ; 142(3): 259-274, 2020 07 21.
Article in English | MEDLINE | ID: mdl-32351122

ABSTRACT

BACKGROUND: Significant improvements in myocardial structure and function have been reported in some patients with advanced heart failure (termed responders [R]) following left ventricular assist device (LVAD)-induced mechanical unloading. This therapeutic strategy may alter myocardial energy metabolism in a manner that reverses the deleterious metabolic adaptations of the failing heart. Specifically, our previous work demonstrated a post-LVAD dissociation of glycolysis and oxidative-phosphorylation characterized by induction of glycolysis without subsequent increase in pyruvate oxidation through the tricarboxylic acid cycle. The underlying mechanisms responsible for this dissociation are not well understood. We hypothesized that the accumulated glycolytic intermediates are channeled into cardioprotective and repair pathways, such as the pentose-phosphate pathway and 1-carbon metabolism, which may mediate myocardial recovery in R. METHODS: We prospectively obtained paired left ventricular apical myocardial tissue from nonfailing donor hearts as well as R and nonresponders at LVAD implantation (pre-LVAD) and transplantation (post-LVAD). We conducted protein expression and metabolite profiling and evaluated mitochondrial structure using electron microscopy. RESULTS: Western blot analysis shows significant increase in rate-limiting enzymes of pentose-phosphate pathway and 1-carbon metabolism in post-LVAD R (post-R) as compared with post-LVAD nonresponders (post-NR). The metabolite levels of these enzyme substrates, such as sedoheptulose-6-phosphate (pentose phosphate pathway) and serine and glycine (1-carbon metabolism) were also decreased in Post-R. Furthermore, post-R had significantly higher reduced nicotinamide adenine dinucleotide phosphate levels, reduced reactive oxygen species levels, improved mitochondrial density, and enhanced glycosylation of the extracellular matrix protein, α-dystroglycan, all consistent with enhanced pentose-phosphate pathway and 1-carbon metabolism that correlated with the observed myocardial recovery. CONCLUSIONS: The recovering heart appears to direct glycolytic metabolites into pentose-phosphate pathway and 1-carbon metabolism, which could contribute to cardioprotection by generating reduced nicotinamide adenine dinucleotide phosphate to enhance biosynthesis and by reducing oxidative stress. These findings provide further insights into mechanisms responsible for the beneficial effect of glycolysis induction during the recovery of failing human hearts after mechanical unloading.


Subject(s)
Glucose/metabolism , Heart Failure/metabolism , Myocardium/metabolism , Comorbidity , Energy Metabolism , Glycolysis , Heart Failure/etiology , Heart Failure/physiopathology , Heart Ventricles/physiopathology , Heart-Assist Devices , Humans , Metabolic Networks and Pathways , Metabolome , Metabolomics/methods , Oxidation-Reduction , Stroke Volume
5.
Catheter Cardiovasc Interv ; 98(7): 1275-1284, 2021 12 01.
Article in English | MEDLINE | ID: mdl-33682308

ABSTRACT

OBJECTIVE: To identify predictors of 30-day all-cause mortality for patients with cardiogenic shock secondary to acute coronary syndrome (ACS-CS) who require short-term mechanical circulatory support (ST-MCS). BACKGROUND: ACS-CS mortality is high. ST-MCS is an attractive treatment option for hemodynamic support and stabilization of deteriorating patients. Mortality prediction modeling for ACS-CS patients requiring ST-MCS has not been well-defined. METHODS: The Utah Cardiac Recovery (UCAR) Shock database was used to identify patients admitted with ACS-CS requiring ST-MCS devices between May 2008 and August 2018. Pre-ST-MCS clinical, laboratory, echocardiographic, and angiographic data were collected. The primary endpoint was 30-day all-cause mortality. A weighted score comprising of pre-ST-MCS variables independently associated with 30-day all-cause mortality was derived and internally validated. RESULTS: A total of 159 patients (mean age, 61 years; 78% male) were included. Thirty-day all-cause mortality was 49%. Multivariable analysis resulted in four independent predictors of 30-day all-cause mortality: age, lactate, SCAI CS classification, and acute kidney injury. The model had good calibration and discrimination (area under the receiver operating characteristics curve 0.80). A predictive score (ranging 0-4) comprised of age ≥ 60 years, pre-ST-MCS lactate ≥2.5 mmol/L, AKI at time of ST-MCS implementation, and SCAI CS stage E effectively risk stratified our patient population. CONCLUSION: The ACS-MCS score is a simple and practical predictive score to risk-stratify CS secondary to ACS patients based on their mortality risk. Effective mortality risk assessment for ACS-CS patients could have implications on patient selection for available therapeutic strategy options.


Subject(s)
Heart-Assist Devices , Shock, Cardiogenic , Female , Hemodynamics , Hospital Mortality , Humans , Male , Middle Aged , Risk Factors , Shock, Cardiogenic/diagnosis , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Treatment Outcome
6.
Heart Lung Circ ; 29(8): 1226-1233, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32085955

ABSTRACT

BACKGROUND: Studies have indicated differences between Asians and Whites in their propensity for stroke, coronary artery disease, heart failure, bleeding and thrombosis. We investigated whether Asian-Americans on durable left ventricular assist devices (LVADs) exhibit differential morbidity and mortality when compared to Whites. METHODS: We analysed prospectively collected data from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) database to compare the outcomes after LVAD implantation of Asians versus Whites. RESULTS: In total, 7,018 patients were included, 130 were identified as Asian-Americans. Asian-Americans were younger, had lower body mass index, higher serum bilirubin and lower albumin levels. In a multivariable regression model, there was no difference in survival between the two groups. Asian-Americans had lower incidence of device malfunction and after adjusting for multiple factors this remained lower. The adjusted risk of a major safety composite outcome, including major bleeding, major infection, stroke and device malfunction, revealed no difference between the two groups. CONCLUSIONS: Although prior studies have reported worse cardiac surgery outcomes in Asians, in this INTERMACS analysis Asian-Americans appear to have similar survival and risk of adverse events as their White counterparts. The incidence of device malfunction was lower in the Asian-Americans, both in a univariate model and after adjusting for multiple clinical factors. Future, larger studies of Asian-Americans with end-stage heart failure and LVAD support are warranted to confirm these results.


Subject(s)
Asian , Heart Failure/therapy , Heart Ventricles/physiopathology , Heart-Assist Devices , Registries , Adult , Aged , Female , Follow-Up Studies , Heart Failure/ethnology , Heart Failure/physiopathology , Humans , Male , Middle Aged , Retrospective Studies , Stroke Volume , Treatment Outcome , United States/epidemiology , Young Adult
8.
Circulation ; 135(17): 1632-1645, 2017 Apr 25.
Article in English | MEDLINE | ID: mdl-28073805

ABSTRACT

BACKGROUND: Cardiac recovery in response to mechanical unloading by left ventricular assist devices (LVADs) has been demonstrated in subgroups of patients with chronic heart failure (HF). Hallmarks of HF are depletion and disorganization of the transverse tubular system (t-system) in cardiomyocytes. Here, we investigated remodeling of the t-system in human end-stage HF and its role in cardiac recovery. METHODS: Left ventricular biopsies were obtained from 5 donors and 26 patients with chronic HF undergoing implantation of LVADs. Three-dimensional confocal microscopy and computational image analysis were applied to assess t-system structure, density, and distance of ryanodine receptor clusters to the sarcolemma, including the t-system. Recovery of cardiac function in response to mechanical unloading was assessed by echocardiography during turndown of the LVAD. RESULTS: The majority of HF myocytes showed remarkable t-system remodeling, particularly sheet-like invaginations of the sarcolemma. Circularity of t-system components was decreased in HF versus controls (0.37±0.01 versus 0.46±0.02; P<0.01), and the volume/length ratio was increased in HF (0.36±0.01 versus 0.25±0.02 µm2; P<0.0001). T-system density was reduced in HF, leading to increased ryanodine receptor-sarcolemma distances (0.96±0.05 versus 0.64±0.1 µm; P<0.01). Low ryanodine receptor-sarcolemma distances at the time of LVAD implantation predicted high post-LVAD left ventricular ejection fractions (P<0.01) and ejection fraction increases during unloading (P<0.01). Ejection fraction in patients with pre-LVAD ryanodine receptor-sarcolemma distances >1 µm did not improve after mechanical unloading. In addition, calcium transients were recorded in field-stimulated isolated human cardiomyocytes and analyzed with respect to local t-system density. Calcium release in HF myocytes was restricted to regions proximal to the sarcolemma. Local calcium upstroke was delayed (23.9±4.9 versus 10.3±1.7 milliseconds; P<0.05) and more asynchronous (18.1±1.5 versus 8.9±2.2 milliseconds; P<0.01) in HF cells with low t-system density versus cells with high t-system density. CONCLUSIONS: The t-system in end-stage human HF presents a characteristic novel phenotype consisting of sheet-like invaginations of the sarcolemma. Our results suggest that the remodeled t-system impairs excitation-contraction coupling and functional recovery during chronic LVAD unloading. An intact t-system at the time of LVAD implantation may constitute a precondition and predictor for functional cardiac recovery after mechanical unloading.


Subject(s)
Excitation Contraction Coupling , Heart Failure/therapy , Heart-Assist Devices , Myocardial Contraction , Myocytes, Cardiac/pathology , Ventricular Function, Left , Ventricular Remodeling , Adult , Aged , Biopsy , Case-Control Studies , Echocardiography , Female , Heart Failure/metabolism , Heart Failure/pathology , Heart Failure/physiopathology , Humans , Image Processing, Computer-Assisted , Male , Microscopy, Confocal , Middle Aged , Myocytes, Cardiac/metabolism , Prospective Studies , Prosthesis Design , Recovery of Function , Ryanodine Receptor Calcium Release Channel/metabolism , Time Factors , Treatment Outcome
10.
Circ Heart Fail ; 17(9): e011358, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39206544

ABSTRACT

BACKGROUND: Cardiogenic shock (CS) can stem from multiple causes and portends poor prognosis. Prior studies have focused on acute myocardial infarction-CS; however, acute decompensated heart failure (ADHF)-CS accounts for most cases. We studied patients suffering ADHF-CS to identify clinical factors, early in their trajectory, associated with a higher probability of successful outcomes. METHODS: Consecutive patients with CS were evaluated (N=1162). We studied patients who developed ADHF-CS at our hospital (N=562). Primary end point was native heart survival (NHS), defined as survival to discharge without receiving advanced HF therapies. Secondary end points were adverse events, survival, major cardiac interventions, and hospital readmissions within 1 year following index hospitalization discharge. Association of clinical data with NHS was analyzed using logistic regression. RESULTS: Overall, 357 (63.5%) patients achieved NHS, 165 (29.2%) died, and 41 (7.3%) were discharged post advanced HF therapies. Of 398 discharged patients (70.8%), 303 (53.9%) were alive at 1 year. Patients with NHS less commonly suffered cardiac arrest, underwent intubation or pulmonary artery catheter placement, or received temporary mechanical circulatory support, had better hemodynamic and echocardiographic profiles, and had a lower vasoactive-inotropic score at shock onset. Bleeding, hemorrhagic stroke, hemolysis in patients with mechanical circulatory support, and acute kidney injury requiring renal replacement therapy were less common compared with patients who died or received advanced HF therapies. After multivariable adjustments, clinical variables associated with NHS likelihood included younger age, history of systemic hypertension, absence of cardiac arrest or acute kidney injury requiring renal replacement therapy, lower pulmonary capillary wedge pressure and vasoactive-inotropic score, and higher tricuspid annular plane systolic excursion at shock onset (all P<0.05). CONCLUSIONS: By studying contemporary patients with ADHF-CS, we identified clinical factors that can inform clinical management and provide future research targets. Right ventricular function, renal function, pulmonary artery catheter placement, and type and timing of temporary mechanical circulatory support warrant further investigation to improve outcomes of this devastating condition.


Subject(s)
Heart Failure , Shock, Cardiogenic , Humans , Shock, Cardiogenic/therapy , Shock, Cardiogenic/mortality , Shock, Cardiogenic/etiology , Shock, Cardiogenic/physiopathology , Male , Female , Heart Failure/therapy , Heart Failure/physiopathology , Heart Failure/complications , Heart Failure/mortality , Aged , Middle Aged , Retrospective Studies , Aged, 80 and over , Risk Factors , Patient Readmission , Acute Disease , Treatment Outcome , Prognosis
11.
J Am Heart Assoc ; 13(14): e032936, 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-38989825

ABSTRACT

BACKGROUND: Type 2 diabetes is prevalent in cardiovascular disease and contributes to excess morbidity and mortality. We sought to investigate the effect of glycemia on functional cardiac improvement, morbidity, and mortality in durable left ventricular assist device (LVAD) recipients. METHODS AND RESULTS: Consecutive patients with an LVAD were prospectively evaluated (n=531). After excluding patients missing pre-LVAD glycated hemoglobin (HbA1c) measurements or having inadequate post-LVAD follow-up, 375 patients were studied. To assess functional cardiac improvement, we used absolute left ventricular ejection fraction change (ΔLVEF: LVEF post-LVAD-LVEF pre-LVAD). We quantified the association of pre-LVAD HbA1c with ΔLVEF as the primary outcome, and all-cause mortality and LVAD-related adverse event rates (ischemic stroke/transient ischemic attack, intracerebral hemorrhage, gastrointestinal bleeding, LVAD-related infection, device thrombosis) as secondary outcomes. Last, we assessed HbA1c differences pre- and post-LVAD. Patients with type 2 diabetes were older, more likely men suffering ischemic cardiomyopathy, and had longer heart failure duration. Pre-LVAD HbA1c was inversely associated with ΔLVEF in patients with nonischemic cardiomyopathy but not in those with ischemic cardiomyopathy, after adjusting for age, sex, heart failure duration, and left ventricular end-diastolic diameter. Pre-LVAD HbA1c was not associated with all-cause mortality, but higher pre-LVAD HbA1c was shown to increase the risk of intracerebral hemorrhage, LVAD-related infection, and device thrombosis by 3 years on LVAD support (P<0.05 for all). HbA1c decreased from 6.68±1.52% pre-LVAD to 6.11±1.33% post-LVAD (P<0.001). CONCLUSIONS: Type 2 diabetes and pre-LVAD glycemia modify the potential for functional cardiac improvement and the risk for adverse events on LVAD support. The degree and duration of pre-LVAD glycemic control optimization to favorably affect these outcomes warrants further investigation.


Subject(s)
Blood Glucose , Diabetes Mellitus, Type 2 , Glycated Hemoglobin , Heart Failure , Heart-Assist Devices , Ventricular Function, Left , Humans , Male , Heart-Assist Devices/adverse effects , Female , Middle Aged , Diabetes Mellitus, Type 2/blood , Diabetes Mellitus, Type 2/complications , Glycated Hemoglobin/metabolism , Heart Failure/mortality , Heart Failure/blood , Heart Failure/therapy , Heart Failure/physiopathology , Aged , Blood Glucose/metabolism , Prospective Studies , Stroke Volume , Treatment Outcome , Recovery of Function , Risk Factors , Time Factors
12.
Circ Heart Fail ; 17(9): e011827, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39051115

ABSTRACT

BACKGROUND: Cardiogenic shock (CS) mortality remains near 40%. In addition to inadequate cardiac output, patients with severe CS may exhibit vasodilation. We aimed to examine the prevalence and consequences of vasodilation in CS. METHODS: We analyzed all patients hospitalized at a CS referral center who were diagnosed with CS stages B to E and did not have concurrent sepsis or recent cardiac surgery. Vasodilation was defined by lower systemic vascular resistance (SVR), higher norepinephrine equivalent dose, or a blunted SVR response to pressors. Threshold SVR values were determined by their relation to 14-day mortality in spline models. The primary outcome was death within 14 days of CS onset in multivariable-adjusted Cox models. RESULTS: This study included 713 patients with a mean age of 60 years and 27% females; 14-day mortality was 28%, and 38% were vasodilated. The median SVR was 1308 dynes•s•cm-5 (interquartile range, 870-1652), median norepinephrine equivalent was 0.11 µg/kg per minute (interquartile range, 0-0.2), and 28% had a blunted pressor response. Each 100-dynes•s•cm-5 decrease in SVR below 800 was associated with 20% higher mortality (adjusted hazard ratio, 1.23; P=0.004). Each 0.1-µg/kg per minute increase in norepinephrine equivalent dose was associated with 15% higher mortality (adjusted hazard ratio, 1.12; P<0.001). A blunted pressor response was associated with a nearly 2-fold mortality increase (adjusted hazard ratio, 1.74; P=0.003). CONCLUSIONS: Pathophysiologic vasodilation is prevalent in CS and independently associated with an increased risk of death. CS vasodilation can be identified by SVR <800 dynes•s•cm-5, high doses of pressors, or a blunted SVR response to pressors. Additional studies exploring mechanisms and treatments for CS vasodilation are needed.


Subject(s)
Shock, Cardiogenic , Vascular Resistance , Vasodilation , Humans , Female , Male , Shock, Cardiogenic/physiopathology , Shock, Cardiogenic/mortality , Middle Aged , Vasodilation/physiology , Aged , Vascular Resistance/physiology , Norepinephrine , Risk Factors , Retrospective Studies
13.
ASAIO J ; 2024 May 29.
Article in English | MEDLINE | ID: mdl-38810218

ABSTRACT

Currently, the fully magnetically levitated left ventricular assist device (LVAD) HeartMate 3 (HM3) is the only commercially available device for advanced heart failure (HF) patients. However, the left ventricular (LV) functional and structural changes following mechanical unloading and circulatory support (MCS) with the HM3 have not been investigated. We compared the reverse remodeling induced by the HM3 to older generation continuous-flow LVADs. Chronic HF patients (n = 405) undergoing MCS with HeartWare Ventricular Assist Device (HVAD, n = 115), HM3 (n = 186), and HeartMate II (HM2, n = 104) at four programs were included. Echocardiograms were obtained preimplant and at 1, 3, 6, and 12 months following LVAD implantation. There were no differences in the postimplant serial LV ejection fraction (LVEF) between the devices. The postimplant LV internal diastolic diameter (LVIDd) was significantly lower for HM2 at 3 and 6 months compared with HVAD and HM3. The proportion of patients achieving "cardiac reverse remodeling responder" status (defined as LVEF improvement to ≥40% and LVIDD ≤5.9 cm) was 11.9%, and was similar between devices. HeartMate 3 appears to result in similar cardiac reverse remodeling as older generation CF-LVADs, suggesting that the fully magnetically levitated device technology could provide an effective platform to further study and promote cardiac reverse remodeling.

14.
J Am Med Inform Assoc ; 31(4): 919-928, 2024 04 03.
Article in English | MEDLINE | ID: mdl-38341800

ABSTRACT

OBJECTIVES: We conducted an implementation planning process during the pilot phase of a pragmatic trial, which tests an intervention guided by artificial intelligence (AI) analytics sourced from noninvasive monitoring data in heart failure patients (LINK-HF2). MATERIALS AND METHODS: A mixed-method analysis was conducted at 2 pilot sites. Interviews were conducted with 12 of 27 enrolled patients and with 13 participating clinicians. iPARIHS constructs were used for interview construction to identify workflow, communication patterns, and clinician's beliefs. Interviews were transcribed and analyzed using inductive coding protocols to identify key themes. Behavioral response data from the AI-generated notifications were collected. RESULTS: Clinicians responded to notifications within 24 hours in 95% of instances, with 26.7% resulting in clinical action. Four implementation themes emerged: (1) High anticipatory expectations for reliable patient communications, reduced patient burden, and less proactive provider monitoring. (2) The AI notifications required a differential and tailored balance of trust and action advice related to role. (3) Clinic experience with other home-based programs influenced utilization. (4) Responding to notifications involved significant effort, including electronic health record (EHR) review, patient contact, and consultation with other clinicians. DISCUSSION: Clinician's use of AI data is a function of beliefs regarding the trustworthiness and usefulness of the data, the degree of autonomy in professional roles, and the cognitive effort involved. CONCLUSION: The implementation planning analysis guided development of strategies that addressed communication technology, patient education, and EHR integration to reduce clinician and patient burden in the subsequent main randomized phase of the trial. Our results provide important insights into the unique implications of implementing AI analytics into clinical workflow.


Subject(s)
Artificial Intelligence , Heart Failure , Humans , Ambulatory Care Facilities , Communication , Heart Failure/therapy , Information Technology
15.
Circ Heart Fail ; : e011709, 2024 Oct 18.
Article in English | MEDLINE | ID: mdl-39421961

ABSTRACT

BACKGROUND: Multidisciplinary Shock Teams have improved clinical outcomes for cardiogenic shock, but their implementation costs have not been studied. This study's objective was to compare costs between patients treated with and without a Shock Team and determine if the team's implementation is cost-effective compared with standard of care. METHODS: We examined patients with refractory cardiogenic shock treated with or without a Shock Team at a tertiary academic hospital from 2009 to 2018. Real-world hospital data were used to compare costs and outcomes, including survival at discharge, 1-year survival, and quality-adjusted life years gained at 1 year. Incremental cost-effectiveness ratios were calculated over a 1-year time horizon, with parameter uncertainty evaluated through probabilistic sensitivity analysis using 1000 second-order Monte Carlo simulations. RESULTS: The study involved 244 patients, with 123 treated by the Shock Team and 121 receiving standard of care. Patients were predominantly male (77.5%), with a mean age of 58 (18-92) years. The Shock Team approach improved survival rates at hospital discharge and 1-year follow-up (61.0% versus 47.9%; P=0.04 and 55.0% versus 40.5%; P=0.03, respectively). The incremental cost-effectiveness ratio for increases in survival probability at discharge for the multidisciplinary Shock Team compared with standard of care was $102 088. The incremental cost-effectiveness ratio for increases in survival probability at 1-year was estimated at $96 152 and at $127 862 per 1 quality-adjusted life year gained. Probabilistic sensitivity analysis estimates showed that the Shock Team was cost-effective in the majority of simulations using a willingness-to-pay threshold of $150 000, while it was also dominant in almost one-third of the simulations. CONCLUSIONS: The Shock Team approach for treating refractory cardiogenic shock may be a cost-effective alternative to traditional standard of care. These findings can help prioritize the implementation of Shock Team initiatives to further improve cardiogenic shock outcomes.

16.
JAMA Cardiol ; 9(3): 272-282, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38294795

ABSTRACT

Importance: The existing models predicting right ventricular failure (RVF) after durable left ventricular assist device (LVAD) support might be limited, partly due to lack of external validation, marginal predictive power, and absence of intraoperative characteristics. Objective: To derive and validate a risk model to predict RVF after LVAD implantation. Design, Setting, and Participants: This was a hybrid prospective-retrospective multicenter cohort study conducted from April 2008 to July 2019 of patients with advanced heart failure (HF) requiring continuous-flow LVAD. The derivation cohort included patients enrolled at 5 institutions. The external validation cohort included patients enrolled at a sixth institution within the same period. Study data were analyzed October 2022 to August 2023. Exposures: Study participants underwent chronic continuous-flow LVAD support. Main Outcome and Measures: The primary outcome was RVF incidence, defined as the need for RV assist device or intravenous inotropes for greater than 14 days. Bootstrap imputation and adaptive least absolute shrinkage and selection operator variable selection techniques were used to derive a predictive model. An RVF risk calculator (STOP-RVF) was then developed and subsequently externally validated, which can provide personalized quantification of the risk for LVAD candidates. Its predictive accuracy was compared with previously published RVF scores. Results: The derivation cohort included 798 patients (mean [SE] age, 56.1 [13.2] years; 668 male [83.7%]). The external validation cohort included 327 patients. RVF developed in 193 of 798 patients (24.2%) in the derivation cohort and 107 of 327 patients (32.7%) in the validation cohort. Preimplant variables associated with postoperative RVF included nonischemic cardiomyopathy, intra-aortic balloon pump, microaxial percutaneous left ventricular assist device/venoarterial extracorporeal membrane oxygenation, LVAD configuration, Interagency Registry for Mechanically Assisted Circulatory Support profiles 1 to 2, right atrial/pulmonary capillary wedge pressure ratio, use of angiotensin-converting enzyme inhibitors, platelet count, and serum sodium, albumin, and creatinine levels. Inclusion of intraoperative characteristics did not improve model performance. The calculator achieved a C statistic of 0.75 (95% CI, 0.71-0.79) in the derivation cohort and 0.73 (95% CI, 0.67-0.80) in the validation cohort. Cumulative survival was higher in patients composing the low-risk group (estimated <20% RVF risk) compared with those in the higher-risk groups. The STOP-RVF risk calculator exhibited a significantly better performance than commonly used risk scores proposed by Kormos et al (C statistic, 0.58; 95% CI, 0.53-0.63) and Drakos et al (C statistic, 0.62; 95% CI, 0.57-0.67). Conclusions and Relevance: Implementing routine clinical data, this multicenter cohort study derived and validated the STOP-RVF calculator as a personalized risk assessment tool for the prediction of RVF and RVF-associated all-cause mortality.


Subject(s)
Cardiovascular System , Heart Failure , Heart-Assist Devices , Humans , Male , Middle Aged , Cohort Studies , Heart-Assist Devices/adverse effects , Prospective Studies , Risk Factors , Female , Adult , Aged
17.
bioRxiv ; 2024 Apr 20.
Article in English | MEDLINE | ID: mdl-38659908

ABSTRACT

Mechanical unloading and circulatory support with left ventricular assist devices (LVADs) mediate significant myocardial improvement in a subset of advanced heart failure (HF) patients. The clinical and biological phenomena associated with cardiac recovery are under intensive investigation. Left ventricular (LV) apical tissue, alongside clinical data, were collected from HF patients at the time of LVAD implantation (n=208). RNA was isolated and mRNA transcripts were identified through RNA sequencing and confirmed with RT-qPCR. To our knowledge this is the first study to combine transcriptomic and clinical data to derive predictors of myocardial recovery. We used a bioinformatic approach to integrate 59 clinical variables and 22,373 mRNA transcripts at the time of LVAD implantation for the prediction of post-LVAD myocardial recovery defined as LV ejection fraction (LVEF) ≥40% and LV end-diastolic diameter (LVEDD) ≤5.9cm, as well as functional and structural LV improvement independently by using LVEF and LVEDD as continuous variables, respectively. To substantiate the predicted variables, we used a multi-model approach with logistic and linear regressions. Combining RNA and clinical data resulted in a gradient boosted model with 80 features achieving an AUC of 0.731±0.15 for predicting myocardial recovery. Variables associated with myocardial recovery from a clinical standpoint included HF duration, pre-LVAD LVEF, LVEDD, and HF pharmacologic therapy, and LRRN4CL (ligand binding and programmed cell death) from a biological standpoint. Our findings could have diagnostic, prognostic, and therapeutic implications for advanced HF patients, and inform the care of the broader HF population.

18.
J Heart Lung Transplant ; 42(7): 853-858, 2023 07.
Article in English | MEDLINE | ID: mdl-37086251

ABSTRACT

By unloading the failing heart, left ventricular (LV) assist devices (LVADs) provide a favorable environment for reversing adverse structural and functional cardiac changes. Prior reports have suggested that an improved native LV function might contribute to the development of LVAD thrombosis. We used the Interagency Registry for Mechanically Assisted Circulatory Support and found that LV functional improvement is associated with a lower risk for device thrombosis. The risk for cerebrovascular accident and transient ischemic attack was comparable across post-LVAD LV function subgroups, while the risk of hemolysis was lower in subgroups of patients with better LV function on LVAD support.


Subject(s)
Heart Failure , Heart-Assist Devices , Thrombosis , Humans , Heart , Heart Ventricles , Ventricular Function, Left , Thrombosis/etiology , Heart-Assist Devices/adverse effects
19.
bioRxiv ; 2023 Sep 17.
Article in English | MEDLINE | ID: mdl-37745322

ABSTRACT

Cardiomyocytes in the adult human heart show a regenerative capacity, with an annual renewal rate around 0.5%. Whether this regenerative capacity of human cardiomyocytes is employed in heart failure has been controversial. Using retrospective 14C birth dating we analyzed cardiomyocyte renewal in patients with end-stage heart failure. We show that cardiomyocyte generation is minimal in end-stage heart failure patients at rates 18-50 times lower compared to the healthy heart. However, patients receiving left ventricle support device therapy, who showed significant functional and structural cardiac improvement, had a >6-fold increase in cardiomyocyte renewal relative to the healthy heart. Our findings reveal a substantial cardiomyocyte regeneration potential in human heart disease, which could be exploited therapeutically.

20.
J Clin Med ; 11(22)2022 Nov 17.
Article in English | MEDLINE | ID: mdl-36431279

ABSTRACT

The time between onset of cardiogenic shock and initiation of mechanical circulatory support is inversely related to patient survival as delays in transporting patients to the operating room (OR) for venoarterial extracorporeal membrane oxygenation (VA ECMO) could prove fatal. A primed and portable VA ECMO system may allow faster initiation of ECMO in various hospital locations and subsequently improve outcomes for patients in cardiogenic shock. We reviewed our institutional experience with VA ECMO based on two time periods: beginning of our VA ECMO program and from initiation of our primed and portable in-hospital ECMO system. The primary endpoint was patient survival to discharge. A total of 137 patients were placed on VA ECMO during the study period; n = 66 (48%) before and n = 71 (52%) after program initiation. In the second era, the proportion of OR ECMO initiation decreased significantly (from 92% to 49%, p < 0.01) as more patients received ECMO in other hospital units, including the emergency department (p < 0.01) and during cardiac arrest (12% vs. 38%, p < 0.01). Survival to hospital discharge was equivalent between the two groups (30% vs. 42%, p = 0.1) despite more patients being placed on ECMO during ongoing cardiac arrest. Finally, we observed increased clinical volume since initiation of the in-hospital, portable ECMO system. Developing an in-hospital, primed and portable VA ECMO program resulted in increased clinical volume with equivalent patient survival despite a sicker cohort of patients. We conclude that more rapid deployment of VA ECMO may extend the treatment eligibility to more patients and improve patient outcomes.

SELECTION OF CITATIONS
SEARCH DETAIL