Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 142
Filter
Add more filters

Country/Region as subject
Affiliation country
Publication year range
1.
Chin J Traumatol ; 26(6): 363-368, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37598017

ABSTRACT

PURPOSE: Hip fractures in elderly have a high mortality. However, there is limited literature on the excess mortality seen in hip fractures compared to the normal population. The purpose of this study was to compare the mortality of hip fractures with that of age and gender matched Indian population. METHODS: There are 283 patients with hip fractures aged above 50 years admitted at single centre prospectively enrolled in this study. Patients were followed up for 1 year and the follow-up record was available for 279 patients. Mortality was assessed during the follow-up from chart review and/or by telephonic interview. One-year mortality of Indian population was obtained from public databases. Standardized mortality ratio (SMR) (observed mortality divided by expected mortality) was calculated. Kaplan-Meir analysis was used. RESULTS: The overall 1-year mortality was 19.0% (53/279). Mortality increased with age (p < 0.001) and the highest mortality was seen in those above 80 years (aged 50 - 59 years: 5.0%, aged 60 - 69 years: 19.7%, aged 70 - 79 years: 15.8%, and aged over 80 years: 33.3%). Expected mortality of Indian population of similar age and gender profile was 3.7%, giving a SMR of 5.5. SMR for different age quintiles were: 3.9 (aged 50 - 59 years), 6.6 (aged 60 - 69 years), 2.2 (aged 70 - 79 years); and 2.0 (aged over 80 years). SMR in males and females were 5.7 and 5.3, respectively. CONCLUSIONS: Indian patients sustaining hip fractures were about 5 times more likely to die than the general population. Although mortality rates increased with age, the highest excess mortality was seen in relatively younger patients. Hip fracture mortality was even higher than that of myocardial infarction, breast cancer, and cervical cancer.


Subject(s)
Hip Fractures , Aged , Aged, 80 and over , Female , Humans , Male , Asian People , Databases, Factual , Hip Fractures/mortality , Hospitalization , Risk Factors , India , Middle Aged
2.
Eur J Orthop Surg Traumatol ; 33(4): 803-809, 2023 May.
Article in English | MEDLINE | ID: mdl-35119486

ABSTRACT

INTRODUCTION: Uncommon but increasingly diagnosed, ipsilateral femoral neck and shaft fracture represents a complex injury pattern with challenging management. The conundrum involves optimal diagnostic modality, timing of surgery, sequence of fixation, and the choice of implant. METHODOLOGY: A retrospective review was conducted at a Level-I trauma centre to assess the outcome of concomitant femoral neck and shaft fractures managed with various implants and attempt to provide solutions to the aforementioned queries. The time between injury and definitive surgery, choice of implant, sequence of fixation, time to fracture union, and complications were documented and analyzed. RESULTS: A total of 46 patients were included in the study wherein associated neck fracture was identified preoperatively in 93.5% of patients. In patients with isolated limb fractures, the mean time to surgery was 16.7 ± 5 h whereas patients with polytrauma witnessed an average delay of 4.6 days before fracture fixation. 72% of patients were managed by dual implants and in the remaining both the fractures were addressed using a single implant with no union time difference amongst implants. The mean time to the union for neck fracture was 21.7 weeks and 24.2 weeks for shaft femur fracture. 21.7% patients developed delayed union of fracture shaft femur and infection complicated 11% shaft fractures. CONCLUSION: Although, 6% neck fractures were missed in the series, we advocate that careful pre/intra/post-operative fluoroscopic evaluation of the femoral neck along with a low threshold for a pre-operative CT scan remains the optimal diagnostic modality while avoiding universal employment of computed tomography (CT). With fracture union being unaffected by implant choice, authors suggest that anatomical fixation of the femoral neck is of paramount importance followed by restoration of the length, alignment and rotation of the femoral shaft, and the implant selection primarily depends on surgeon's experience and the pattern of injury.


Subject(s)
Femoral Fractures , Femoral Neck Fractures , Fracture Fixation, Intramedullary , Humans , Femoral Neck Fractures/surgery , Femur Neck , Trauma Centers , Femoral Fractures/surgery , Fracture Fixation , Retrospective Studies
3.
Eur J Orthop Surg Traumatol ; 33(7): 3001-3010, 2023 Oct.
Article in English | MEDLINE | ID: mdl-36934361

ABSTRACT

PURPOSE: One of the major limitations of the 2D fracture evaluation (Schatzker classification) is its failure to adequately assess fracture lines in the frontal plane and fracture displacement in the antero-posterior direction. 3D fracture line mapping includes steric assessment which can aid decision making with regards to the surgical approach and fixation scheme. We hypothesized that there are consistent fracture patterns and zones of comminution for proximal tibial fractures. METHODS: Radiographic data of 228 proximal tibia fractures were retrospectively included in this study. Fracture lines and zones of comminution were graphically superimposed onto a 3D template of an intact tibia after virtual reduction and normalization to identify major patterns of fracture and comminution. RESULTS: Out of 206 male and 21 female patients, 89 had a fracture of the lateral condyle only (Schatzker I and II), 53 involved the medial plateau only (Schatzker IV) and 86 had a high-grade fracture involving both the condyles (Schatzker V and VI). 64.5% of the fracture lines involving the medial plateau alone were in the coronal plane, and this number was even lesser (44.2%) in medial plateau involvement of bicondylar fractures. In bicondylar fractures, lines were usually not seen to pass directly through the posteromedial region. CONCLUSIONS: Medial tibial plateau fractures have a mix of coronal or sagittal fracture alignment. A clearer understanding of the 3D orientations of fractures based on CT scans can aid in diagnosing the pattern of fracture and adequate positioning of plates can be done to eventually improve operative outcomes.


Subject(s)
Fractures, Comminuted , Tibial Fractures , Humans , Male , Female , Tibia/diagnostic imaging , Tibia/surgery , Retrospective Studies , Tibial Fractures/diagnostic imaging , Tibial Fractures/surgery , Imaging, Three-Dimensional , Fracture Fixation, Internal
4.
Eur J Orthop Surg Traumatol ; 33(6): 2261-2270, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36282333

ABSTRACT

PURPOSE: In today's era, fractures of the femur are primarily managed with intramedullary devices. Keeping in mind the anatomical sagittal bow of the femur, intramedullary devices have been devised with an anterior bow, but this varies amongst various manufacturers - leading to complications such as anterior cortex impingement beyond the isthmus and posterior cortical opening at the fracture site. We intend to find the average radius of curvature (ROC) of the anatomical bow of the femur and the variation of the same. METHODS: Radiographic data of 150 normal femur scans done in 81 patients were loaded in the Mimics 21.0 software (Materialise, Leuven, Belgium). A centerline (of the medullary cavity) was created using the software. A best-fit circle was created in the sagittal plane involving a major part of the centerline, and ROC was calculated. RESULTS: We found the average ROC of our data was 1027.2, with a standard deviation of 241.55. ROC and length of the femur (an indirect measure of height) had a slight positive correlation (r = 0.36; p < 0.05); and a highly positive correlation in the ROC of the left and right femurs of the same individuals (r = 0.605; p < 0.05). CONCLUSIONS: The usual ROC of intramedullary nails is commonly > 1300 mm, much higher than the average ROC we identified in our population. Thus, we conclude that implants with smaller ROC in the range of 1100 mm are needed, leading to better implant placement in the canal and avoiding complications of anterior cortex impingement and preventing fracture gap widening in our setting.


Subject(s)
Femoral Fractures , Fracture Fixation, Intramedullary , Humans , Radius , Bone Nails , Femoral Fractures/diagnostic imaging , Femoral Fractures/surgery , Femur/diagnostic imaging , Femur/surgery , Fracture Fixation, Intramedullary/adverse effects , Tomography, X-Ray Computed
5.
Am J Emerg Med ; 53: 118-121, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35016093

ABSTRACT

INTRODUCTION: Point of care ultrasound (POCUS) has variable diagnostic accuracy in diagnosing fractures. Waterbath technique is a modification of the conventional ultrasound technique which may improve diagnostic accuracy by enhancing image quality. Authors studied the diagnostic accuracy of waterbath technique compared to the final diagnosis based on clinical examination and radiology in the identification of fractures of hand and foot. METHODS: Patients of >18 yrs. age with suspected distal hand and foot fractures presenting to the emergency department of a level 1 trauma center were recruited after informed consent. Unconscious and hemodynamically unstable patients, injuries >72 h old, open fractures, obvious deformities, and old fractures at the affected site were excluded. Cases were subjected to waterbath technique performed by an academic emergency medicine resident and relevant radiographs were ordered and interpreted by an orthopedic specialist. CT/MRI, if done in case of discrepancy, was interpreted by radiologist. The findings of both waterbath technique and radiology were blinded to each other and compared to the final diagnosis made by a cumulative assessment of clinical examination, radiographs, and CT/MRI of the discrepant cases. RESULTS: Waterbath technique identified fractures of hand and foot with sensitivity of 97% (95% CI 90%-100%), specificity 94% (95%CI 81%-99%), PPV 98% (95%CI 91%-99%), NPV 94% (95%CI 79%-98%), LR+ 17.5(95% CI 4.5-67.2), LR- 0.03(95% CI 0.01-0.12) and diagnostic accuracy 96% (95%CI 91%-99%). CONCLUSION: This pilot study has demonstrated the utility of Waterbath technique in the diagnosis of fractures of hand and foot in adults in the ED setting. Future well designed studies are required to explore the potential of this novel technique in both adult and pediatric population.


Subject(s)
Fractures, Bone , Adult , Child , Emergency Service, Hospital , Fractures, Bone/diagnostic imaging , Hand , Humans , Pilot Projects , Point-of-Care Systems , Sensitivity and Specificity , Ultrasonography/methods
6.
Chin J Traumatol ; 25(4): 245-248, 2022 Jul.
Article in English | MEDLINE | ID: mdl-33642068

ABSTRACT

Bipolar clavicular dislocation is rare, and therefore its management is contentious. With an increase of patient's physical demand and a near-normal shoulder function, there has been a shift in the paradigm of its management from a conservative one to a stabilized one of anatomical open reduction. Proposed methods of fixation have also evolved with the advent of more biological fixation devices, which elude implant or fixation related complications. This case report highlights the salient features of this rare case and details the management options along with the benefits of biological anatomical repair and reconstruction.


Subject(s)
Acromioclavicular Joint , Joint Dislocations , Acromioclavicular Joint/surgery , Bone Plates , Clavicle/surgery , Fracture Fixation, Internal , Humans , Joint Dislocations/surgery
7.
Chin J Traumatol ; 25(5): 306-310, 2022 Sep.
Article in English | MEDLINE | ID: mdl-34600804

ABSTRACT

Intracapsular fractures of the proximal femur are one of the most common fractures of the lower limbs. Most cases require osteosynthesis with suitable implants, and intraoperative positioning of the patient on the fracture table is a prerequisite to facilitate fracture manipulation, traction, reduction and fluoroscopy assessment. However, positioning the limbs of bilateral above-knee amputees for internal fixation of related proximal femoral fractures is a difficult task, which requires customized inventory for effective limb positioning and fracture manipulation. This study reported a rare case following a crush injury of bilateral lower limb in a road traffic accident, and described some technical tips of acute femoral neck fractures in bilateral above-knee amputation. The patient was managed with immediate guillotine amputation and later secondary wound closure followed by internal fixation of the right-sided femoral neck fracture with multiple cancellous cannulated screws.


Subject(s)
Amputees , Femoral Neck Fractures , Femoral Neck Fractures/surgery , Femur , Fracture Fixation, Internal , Humans , Lower Extremity
8.
Eur J Orthop Surg Traumatol ; 31(4): 643-650, 2021 May.
Article in English | MEDLINE | ID: mdl-33099679

ABSTRACT

BACKGROUND: This study aims to describe an uncommon presentation of posterior wall acetabular fracture-dislocation with displacement of fracture fragment anterior to femoral head with its management and clinico-radiological outcome. METHODS: This retrospective review was performed at a Level I trauma centre over a period of six years. Hospital records, radiological database, operative register and follow-up data identified 7 patients with anteriorly lying posterior wall fragment of acetabulum. Analysis was performed with 6 patients having complete follow-up ranging from 2 to 7 years. The patients were operated with standard Kocher-Langenbeck approach; modification of this approach with trochanteric flip osteotomy and safe surgical dislocation was performed based on the location of the anteriorly lying fragment. Final functional and radiographic outcome was analysed according to modified Merle D'Aubigné and Postel score, and Matta's grade, respectively. RESULTS: This uncommon presentation was observed in 11.11% of patients out of 63 patients with isolated posterior wall acetabular fractures managed during the study period. Anteriorly displaced posterior wall fragment was located in anterosuperior (n, 3), anterocentral (n, 2) and anteroinferior (n, 1) quadrants anterior to the femoral head. Final clinical and radiographic outcome revealed good-to-excellent outcome in 5 (83.33%) patients, and poor in one. One patient developed progressive arthrosis of hip which required total hip arthroplasty within 2 years. CONCLUSION: This unusual pattern of posterior wall fracture requires adequate pre-operative planning, careful handling of the fractured fragments along with its soft tissue attachments during surgery, and preferably a concomitant trochanteric flip osteotomy with/without surgical hip dislocation to achieve good results.


Subject(s)
Hip Dislocation , Hip Fractures , Acetabulum/diagnostic imaging , Acetabulum/surgery , Hip Dislocation/diagnostic imaging , Hip Dislocation/surgery , Hip Fractures/diagnostic imaging , Hip Fractures/surgery , Humans , Retrospective Studies , Treatment Outcome
9.
Int Orthop ; 44(4): 655-664, 2020 04.
Article in English | MEDLINE | ID: mdl-31838545

ABSTRACT

INTRODUCTION: Morphometric variations of the anterior column of the acetabulum have been described in the literature for its complex structure, which can influence the safe containment of intramedullary screw for fixation of its fractures. The purpose of this CT-based study is to present a preliminary report on the morphometric variations and safety of intramedullary screw fixation of the anterior column of the acetabulum in the Indian population. METHODS: CT-based data from 102 uninjured pelves were retrospectively analyzed in iPlanⓇ BrainLab AG, Feldkirchen, Germany. Narrowest zones around acetabulum and superior pubic ramus were measured. We calculated the axis of the anterior column of the acetabulum by joining the centres of these narrowest zones. Standard screws trajectories were directed along this axis. Screw length up to the first cortical perforation, the distance of the exit point from the pubic symphysis, and the length of the anterior column up to the pubic tubercle were measured. RESULTS: The osseous corridor of the anterior column of acetabulum had variable cross-section along its length with two constriction zones, first in the acetabular region and second in the superior pubic ramus. Only 54% of our cases allowed safe applicability of 6.5-mm-diameter screw trajectories with safety margin of 2 mm on either side of the screw. Significant morphometric and screw applicability-related differences were observed among male and female cases with males having a wider osseous corridor in general. Elimination of safety margin results in a significant increase in the screw applicability. CONCLUSION: The osseous corridor of the anterior column varies in its dimensions from individual to individual. Standard screws of 6.5-mm and 7.3-mm diameters may not be safe for intramedullary screw fixation in every patient and carry a risk of cortical violation when a 2 mm of width around the screw is considered as a safety margin. However, with a precise screw placement within the extents of the cortices of the anterior column, 6.5-mm screws can be applied in most of the female cases and 7.3-mm screws can be applied in most of the male cases for anterior column fixation.


Subject(s)
Acetabulum/surgery , Bone Screws , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Acetabulum/diagnostic imaging , Adolescent , Adult , Aged , Female , Humans , India , Male , Middle Aged , Preliminary Data , Pubic Bone/diagnostic imaging , Pubic Bone/surgery , Radiology , Retrospective Studies , Treatment Outcome , Young Adult
10.
Int Orthop ; 44(10): 1881-1885, 2020 10.
Article in English | MEDLINE | ID: mdl-32748026

ABSTRACT

Pelvic-acetabulum and spine surgery are two important constituents of complex trauma surgery and require a gamut of resources for fracture management. In the pandemic crisis of COVID-19 where existing health care resources are scarce and a major section of health care infrastructure has been assigned to fight against it, the compromised and less equipped health care facility is left to tackle the ongoing presentation of complex trauma surgery. One major challenge faced to manage these complex procedures is the availability of specialized radiolucent operation tables as even the apex level health care setups generally have one or two such kinds of table. Therefore, in this state of pandemic crisis, innovations utilizing the available local resources need to be developed to avoid deferring these complex operations.


Subject(s)
Betacoronavirus , Coronavirus Infections , Operating Tables , Orthopedic Procedures , Pandemics , Pneumonia, Viral , COVID-19 , Fractures, Bone/surgery , Humans , SARS-CoV-2
11.
Infection ; 47(6): 1055-1057, 2019 Dec.
Article in English | MEDLINE | ID: mdl-30953325

ABSTRACT

We report a rare case of post-traumatic cutaneous diphtheria in a patient referred from a hospital in rural India. The diagnosis of cutaneous diphtheria was confirmed by the isolation of Corynebacterium diphtheriae cultured from the ulcer of the leg, along with Staphylococcus aureus, Streptococcus pyogenes, and Arcanobacterium haemolyticum. The patient was kept on isolation and treated with erythromycin for 14 days without antitoxin. He was discharged when his subsequent cultures turned out to be negative. Chemoprophylaxis was also given to his family members. Such a case highlights the revisiting of vaccination strategies and the role of cutaneous carriers in transmission of this deadly disease.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Corynebacterium diphtheriae/isolation & purification , Diphtheria/diagnosis , Erythromycin/therapeutic use , Skin Diseases/diagnosis , Adult , Diphtheria/classification , Diphtheria/microbiology , Humans , India , Male , Skin Diseases/microbiology , Treatment Outcome
12.
Chin J Traumatol ; 21(1): 42-49, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29426797

ABSTRACT

PURPOSE: Cerclage wire application has emerged as a potential therapeutic adjunct to intramedullary nailing for subtrochanteric fractures. But its popularity is plagued by the concern of possible negative effect on fracture zone biology. This study was intended to analyze the clinico-radiological outcome and complications associated with cerclage wire application. METHODS: Retrospective analysis was performed on all the subtrochanteric fractures operated with intramedullary nailing between January 2012 and January 2016. After exclusion, 48 patients were available with an average follow-up of 20.8 months. Long oblique, spiral, spiral wedge or comminuted fracture configurations with butterfly fragments were particularly considered for cerclage wire application, which was employed by percutaneous cerclage passer in 21 patients. Assessment was done in terms of operation time, blood loss, quality of reduction, neck-shaft angle, follow-up redisplacement, union time, complications, and final functional evaluation by Merle d'Aubigne'-Postel score. RESULTS: Average operation time and blood loss were significantly higher in cerclage group (p < 0.05). However, cerclage use substantially improved quality of reduction in terms of maximum cortical displacement (p = 0.003) and fracture angulation (p = 0.045); anatomical reduction was achieved in 95.23% of cases as compared to 74.07% without cerclage. Union time was shorter, although not statistically different (p = 0.208), in cerclage group. Four patients in non-cerclage group developed non-union, 2 of them had nail breakage. No infection or any other implant related complications were reported with cerclage use. CONCLUSION: Minimally-invasive cerclage wire application has proved to be beneficial for anatomical reconstruction in difficult subtrochanteric fractures, whenever applicable, without any harmful effect on fracture biology.


Subject(s)
Bone Wires , Fracture Fixation, Intramedullary/methods , Hip Fractures/surgery , Adult , Aged , Female , Fracture Fixation, Intramedullary/adverse effects , Humans , Male , Middle Aged , Retrospective Studies
13.
J Shoulder Elbow Surg ; 26(10): e293-e299, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28522075

ABSTRACT

BACKGROUND: Fracture-dislocation is the extreme variant of injury to the proximal humerus that occurs more commonly in young adults as a result of high-velocity trauma. We evaluated the functional and radiologic outcome of fixation of proximal humeral fracture-dislocations with locked plates. METHODS: This was a retrospective review of 33 proximal humeral fracture-dislocations in 29 patients with a mean age of 35 years (range, 19-60 years) treated by open reduction and internal fixation with locked plates between January 2009 and December 2013. The fracture-dislocation in 85% was the result of high-energy trauma resulting in 3- or 4-part fracture-dislocation. The fracture-dislocation was anterior in 27 and posterior in 6. RESULTS: The average delay from injury to surgery was 7 days (range, 1-35 days), with a mean follow-up of 40 months (range, 24-66 months). All of the fractures united at an average of 15 weeks after surgery. At the final follow-up, the mean forward flexion was 129° (range, 100°-160°), and mean abduction was 128° (range, 100°-150°). The mean Constant score at the final follow-up was 78 points (range, 68-88 points). One case of complete osteonecrosis of the humeral head and 1 case of partial osteonecrosis of the humeral head were noted. Two cases of screw perforation of the humeral head were seen, with subsequent restricted range of motion improving after removal of the offending screws. CONCLUSIONS: Most young patients with 3- and 4-part proximal humeral fracture-dislocations can achieve good functional outcome after fixation with locked plates.


Subject(s)
Bone Plates , Fracture Dislocation/surgery , Fracture Fixation, Internal , Shoulder Fractures/surgery , Adult , Bone Screws , Female , Follow-Up Studies , Fracture Healing , Humans , Male , Middle Aged , Range of Motion, Articular , Retrospective Studies , Young Adult
16.
Med Princ Pract ; 23(3): 275-8, 2014.
Article in English | MEDLINE | ID: mdl-24335075

ABSTRACT

OBJECTIVE: To report a case of subtrochanteric femur fracture that led to intraoperative compartment syndrome in the well leg. CLINICAL PRESENTATION AND INTERVENTION: A 28-year-old obese male who presented with a comminuted subtrochanteric fracture underwent a prolonged open reduction and internal fixation using dynamic condylar screw. In the postoperative period, after the effect of epidural analgesia had worn off, the patient complained of severe pain and swelling of the well leg. A diagnosis of well-leg compartment syndrome was made and urgent two-incision fasciotomy was performed. CONCLUSION: Obesity and prolonged surgery could have caused the acute compartment syndrome of the well leg in this patient.


Subject(s)
Compartment Syndromes/etiology , Fractures, Comminuted/surgery , Hip Fractures/surgery , Postoperative Complications/etiology , Adult , Bone Screws , Compartment Syndromes/epidemiology , Humans , Male , Obesity/epidemiology , Postoperative Complications/epidemiology
17.
Injury ; 55 Suppl 2: 111357, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39098785

ABSTRACT

Recent studies report the overall incidence of distal femur fractures as 8.7/100,000/year. This incidence is expected to rise with high energy motor vehicle collisions and elderly osteoporotic fractures in native and prosthetic knees keep increasing. These fractures are more common in males in the younger age spectrum while females predominate for elderly osteoporotic fractures. Surgical treatment is recommended for these fractures to maintain articular congruity, enable early joint motion and assisted ambulation. Over the last two decades, development of minimally invasive and quadriceps sparing surgical approaches, availability of angle stable implants have helped achieve predictable healing and early return to function in these patients. Currently, laterally positioned locked plate is the implant of choice across all fracture patterns. Retrograde with capital implantation of intramedullary nails with provision for multiplanar distal locking is preferred for extra-articular and partial articular fractures. Even with these advancements, nonunion after distal femur fracture fixation can be as high as 19%. Further recent research has helped us understand the biomechanical limitations and healing problems with lateral locked plate fixation and intramedullary nails. This has lead to development of more robust constructs such as nail-plate and double plate constructs aiming for improved construct strength and to minimise failures. Early results with these combination constructs have shown promise in high risk situations such as fractures with extensive metaphyseal fragmentation, osteoporosis and periprosthetic fractures. These constructs however, run the risk of being over stiff and can inhibit healing if not kept balanced. The ideal stiffness that is needed for fracture healing is not clearly known and current research in this domain has lead to the development of smart implants which are expected to evolve and may help improve clinical results in future.


Subject(s)
Bone Plates , Femoral Fractures, Distal , Fracture Fixation, Intramedullary , Fracture Healing , Aged , Female , Humans , Male , Biomechanical Phenomena , Bone Nails , Femoral Fractures, Distal/physiopathology , Femoral Fractures, Distal/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Intramedullary/methods , Fracture Healing/physiology , Osteoporotic Fractures/surgery , Osteoporotic Fractures/physiopathology , Treatment Outcome
18.
Arch Bone Jt Surg ; 12(5): 342-348, 2024.
Article in English | MEDLINE | ID: mdl-38817416

ABSTRACT

Objectives: Pre-operative assessment is routinely performed for all hip fractures, and include a thorough clinical examination and multiple pre-operative tests. While abnormalities are often detected in many tests, they have varied effect on mortality. The purpose of the study was to assess the prevalence and impact of these abnormal tests and comorbidities. Methods: This was a prospective study of 283 consecutive hip fracture patients aged above 50 years admitted in a major trauma hospital from February 2019 to December 2019. The prevalence of abnormalities in the following tests were assessed: chest x-ray, electrocardiogram, complete blood count, serum electrolytes, renal function test, prothrombin time/international normalized ratio, and serum bilirubin. Also, presence of comorbidities were recorded. Mortality within 90 days of admission was assessed. Results: 91.5% (N= 259/283) of the patients had at least one abnormal investigation. The most common abnormal investigation was anemia (70.3%, N= 199/283), followed by deranged sodium (36.4%, N= 103/283). 17.7% (N= 50/283) of the patients had at least one new comorbidity diagnosed after admission. The most common newly diagnosed comorbidity was hypertension (10.6%, N= 30/283). Anemia (p=0.044), deranged sodium (p=0.002), raised urea (p=0.018), raised creatinine (p=0.002), renal disease (p=0.015), neurological diseases (p=0.024), and charlson comorbidity index (p=0.004) were associated with increased mortality in multivariate analysis. Conclusion: Pre-operative hemoglobin, sodium, urea, and creatinine were the most important tests influencing mortality, and derangements of these should therefore be carefully evaluated and managed. Hip fracture care pathways should focus on correction of these abnormalities.

19.
J Clin Orthop Trauma ; 56: 102540, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39328296

ABSTRACT

Introduction: Acetabular fractures, resulting from high-energy trauma, present significant orthopaedic challenges. Despite their rarity, the incidence of these fractures is rising, necessitating a comprehensive understanding of their epidemiological characteristics, especially in diverse populations like India. Methods: This retrospective study analyzed data from 3643 patients across four level-1 trauma centers in India (North 1, North 2, West, and South) from January 2001 to December 2019. Prior ethical approval was obtained from the respective institutions. Data were collected using the computerized patient record system (CPRS) and included patients with complete clinical and radiological records. Only patients with full radiological data were included, comprising standard anteroposterior radiograph, Judet views on radiographs, and computed tomography scan of the pelvis. The study evaluated the demographic characteristics, fracture patterns and surgical approaches. Results: The majority of patients were males (84.05 %) and the fractures were mostly seen in young individuals between 19 and 40 years' age group (44.9 %), followed by 41-60 years (42.3 %). Associated bony or other system injuries were seen in 53.42 % of patients, with pelvic injuries being the most common (9.8 %). Posterior wall fractures were the most frequent (20.7 %), while anterior wall fractures were the least common (0.8 %). Operative management was employed in 82 % of cases, with the Kocher-Langenbeck approach being the most commonly employed (42.5 %). Conclusion: High-velocity trauma remains the commonest cause of acetabular trauma in India, primarily affecting young male individuals. Pelvic fractures are the most commonly associated injuries. Posterior wall fractures are the commonest type of acetabular fracture, and the Kocher-Langenbeck approach is the commonly adopted surgical approach.

20.
Indian J Med Res ; 137(1): 111-6, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23481059

ABSTRACT

BACKGROUND & OBJECTIVES: Perioperative antimicrobial prophylaxis constitutes the bulk of antimicrobial consumption in any hospital. This study was conducted at a level 1 Trauma Centre of a tertiary care hospital of India to assess the efficacy of a short (24 h) course of perioperative antibiotic prophylactic regimen in preventing surgical site infections (SSI) in open reduction and internal fixation (ORIF) of closed fractures of limbs and to assess if the same can be implemented as a general policy. METHODS: Patients of either sex, aged 18 yr or more, who were scheduled for ORIF and were willing and able to give informed consent, were included in the study. Patients were randomly allocated into two groups. Group 1 (n=100) received 3 doses of 1 g i.v. cefuroxime perioperatively spaced 12 h apart and group 2 (n=97) received the conventional existing regimen [5 days of i.v. antibiotics (cefuroxime 1 g twice daily along with amikacin 15 mg/kg in 2 divided doses), followed by oral cefuroxime, 500 mg twice daily till suture removal]. RESULTS: Of the 197 patients, four patients developed a surgical site infection (three with methicillin resistant Staphylococcus aureus and one Acinetobacter baumanii). Of these, two patients were in group 1 and the remaining two in group 2. These patients were treated with i.v. antibiotics based on the culture and antimicrobial sensitivity reports. The cost of the short course treatment was ` 150 per patient as compared to ` 1,900 per patient for conventional regimen. INTERPRETATION & CONCLUSIONS: There was no significant difference in rates of SSI among the two groups in our study. Cost evaluation revealed that shorter course was less expensive than conventional long course regimen. Implementation of a short course perioperative regimen will go a long way in reducing antimicrobial resistance, cost and adverse reactions to antimicrobials.


Subject(s)
Anti-Bacterial Agents/administration & dosage , Antibiotic Prophylaxis , Fractures, Closed/microbiology , Surgical Wound Infection/microbiology , Adolescent , Adult , Aged , Female , Fractures, Closed/drug therapy , Humans , India , Male , Methicillin-Resistant Staphylococcus aureus/drug effects , Methicillin-Resistant Staphylococcus aureus/pathogenicity , Middle Aged , Orthopedics/methods , Postoperative Period , Surgical Wound Infection/drug therapy
SELECTION OF CITATIONS
SEARCH DETAIL