Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Database
Language
Journal subject
Affiliation country
Publication year range
1.
J Endovasc Ther ; 26(6): 855-864, 2019 12.
Article in English | MEDLINE | ID: mdl-31736427

ABSTRACT

Purpose: To evaluate if the radial force of the double sealing ring of the Anaconda stent-graft induces dilatation in the perirenal aortic neck adjacent to the rings. Materials and Methods: This study evaluated the serial electrocardiogram-gated computed tomography scans of 15 abdominal aortic aneurysm patients (mean age 72.8±3.7 years; 14 men) who were treated electively using an Anaconda stent-graft. Follow-up scans were conducted before discharge and at 1, 6, 12, and 24 months after endovascular repair. Diameter and area were assessed perpendicular to the aortic centerline along the perirenal aortic neck, which was subdivided into 3 zones: the suprastent, the stent, and the infrastent zones. Measurements were performed independently by 2 experienced observers using dedicated 3-dimensional image processing software. Results: Between discharge and the 2-year follow-up the diameter and area remained stable in the suprastent zone [average diameter change: -0.1±0.4 mm (-0.4%±1.7%), p=0.893; average area change: -2.9±17.2 mm2 (-0.7%±3.4%), p=0.946], increased in the stent zone [average diameter change: +1.9±1.0 mm (+7.3%±4.0%), p<0.001; average area change: +84.3±48.3 mm2 (+15.5%±8.7%), p<0.001], and diverged in the infrastent zone [average diameter change: -0.8±2.2 mm (-2.3%±7.4%), p>0.99; average area change: -34.6±102.3 mm2 (-4.1%±14.8%), p>0.99; increased in 4 patients, decreased in 9 patients]. Conclusion: After Anaconda implantation the infrarenal aortic neck accommodated to the expansion of the sealing rings at the stent zone. Below the stent zone the neck diameter decreased in the majority of patients, while an increase was related to downstream displacement of the main body. A decrease in size in the infrastent zone may contribute to durable sealing and fixation. A personalized follow-up scheme based on geometric neck remodeling should be feasible if our observations are confirmed in larger, long-term studies.


Subject(s)
Aorta, Abdominal/surgery , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Vascular Remodeling , Aged , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/physiopathology , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Female , Humans , Male , Prosthesis Design , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL