Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 109
Filter
Add more filters

Publication year range
1.
Pediatr Res ; 2024 Jan 11.
Article in English | MEDLINE | ID: mdl-38200324

ABSTRACT

BACKGROUND AND AIMS: Invasive devices are widely used in healthcare settings; however, pediatric patients are especially vulnerable to invasive device-associated harm. This study aimed to explore invasive device utility, prevalence, harm, and clinical practice across three Australian pediatric tertiary hospitals. METHODS: In 2022-2023, a multi-center, observational, rolling-point-prevalence survey was conducted. Fifty-per-cent of inpatients were systemically sampled by random allocation. Patients with devices were then followed for up to 3-days for device-related complications/failures and management/removal characteristics. RESULTS: Of the 285 patients audited, 78.2% had an invasive device (n = 412 devices), with a median of 1 device-per-patient (interquartile range 1-2), with a maximum of 13 devices-per-patient. Over half of devices were vascular access devices (n = 223; 54.1%), followed by gastrointestinal devices (n = 112; 27.2%). The point-prevalence of all device complications on Day 0 was 10.7% (44/412 devices) and period-prevalence throughout the audit period was 27.7% (114/412 devices). The period-prevalence of device failure was 13.4% (55/412 devices). CONCLUSIONS: The study highlighted a high prevalence of invasive devices among hospitalized patients. One-in-ten devices failed during the audit period. These findings underscore the need for vigilant monitoring and improved strategies to minimize complications and enhance the safety of invasive devices in pediatric hospital settings. IMPACT: A high prevalence of invasive devices among hospitalized patients was reported. Of the 285 patients audited, almost 80% had an invasive device (total 412 devices), with a median of 1 device-per-patient and a maximum of 13 devices-per-patient. The most common devices used in pediatric healthcare are vascular access devices (n = 223; 54.1%), however, 16% (n = 36) of these devices failed, and one-third had complications. The point prevalence of all device complications at day 0 was 10.7% (44 out of 412 devices), with a period prevalence of 27.7% (114 out of 412 devices) throughout the audit period.

2.
Pediatr Res ; 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38937641

ABSTRACT

BACKGROUND: Central venous access devices (CVAD) are associated with central line associated bloodstream infection (CLABSI) and venous thromboembolism (VTE). We identified trends in non-intensive care unit (ICU) CVAD utilization, described complication rates, and compared resources between low and high CVAD sites. METHODS: We combined data from the Pediatric Health Information System (PHIS) database and surveys from included hospitals. We analyzed 10-year trends in CVAD encounters for non-ICU children between 01/2012-12/2021 and described variation and complication rates between 01/2017-12/2021. Using Fisher's exact test, we compared resources between low and high CVAD users. RESULTS: CVAD use decreased from 6.3% to 3.8% of hospitalizations over 10 years. From 2017-2021, 67,830 encounters with CVAD were identified. Median age was 7 (IQR 2-13) years; 46% were female. Significant variation in CVAD utilization exists (range 1.4-16.9%). Rates of CLABSI and VTE were 4.0% and 3.4%, respectively. Survey responses from 33/41 (80%) hospitals showed 91% had vascular access teams, 30% used vascular access selection guides, and 70% used midline/long peripheral catheters. Low CVAD users were more likely to have a team guiding device selection (100% vs 43%, p = 0.026). CONCLUSIONS: CVAD utilization decreased over time. Significant variation in CVAD use remains and may be associated with hospital resources. IMPACT: Central venous access device (CVAD) use outside of the ICU is trending down; however, significant variation exists between institutions. Children with CVADs hospitalized on the acute care units had a CLABSI rate of 4% and VTE rate of 3.4%. 91% of surveyed institutions have a vascular access team; however, the services provided vary between institutions. Even though 70% of the surveyed institutions have the ability to place midline/long peripheral catheters, the majority use these catheters less than a few times per month. Institutions with low CVAD use are more likely to have a vascular access team that guides device selection.

3.
Cochrane Database Syst Rev ; 6: CD013366, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38940297

ABSTRACT

BACKGROUND: Peripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective complications, which PICC materials and design may contribute to, leading to negative sequelae for patients and healthcare systems. OBJECTIVES: To assess the effectiveness of PICC material and design in reducing catheter failure and complications. SEARCH METHODS: The University of Queensland and Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL databases and the WHO ICTRP and ClinicalTrials.gov trials registers to 16 May 2023. We aimed to identify other potentially eligible trials or ancillary publications by searching the reference lists of retrieved included trials, as well as relevant systematic reviews, meta-analyses, and health technology assessment reports. We contacted experts in the field to ascertain additional relevant information. SELECTION CRITERIA: We included randomised controlled trials (RCTs) evaluating PICC design and materials. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. Our primary outcomes were venous thromboembolism (VTE), PICC-associated bloodstream infection (BSI), occlusion, and all-cause mortality. Secondary outcomes were catheter failure, PICC-related BSI, catheter breakage, PICC dwell time, and safety endpoints. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included 12 RCTs involving approximately 2913 participants (one multi-arm study). All studies except one had a high risk of bias in one or more risk of bias domain. Integrated valve technology compared to no valve technology for peripherally inserted central catheter design Integrated valve technology may make little or no difference to VTE risk when compared with PICCs with no valve (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.19 to 2.63; I² = 0%; 3 studies; 437 participants; low certainty evidence). We are uncertain whether integrated valve technology reduces PICC-associated BSI risk, as the certainty of the evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Integrated valve technology may make little or no difference to occlusion risk when compared with PICCs with no valve (RR 0.86, 95% CI 0.53 to 1.38; I² = 0%; 5 studies; 900 participants; low certainty evidence). We are uncertain whether use of integrated valve technology reduces all-cause mortality risk, as the certainty of evidence is very low (RR 0.85, 95% CI 0.44 to 1.64; I² = 0%; 2 studies; 473 participants). Integrated valve technology may make little or no difference to catheter failure risk when compared with PICCs with no valve (RR 0.80, 95% CI 0.62 to 1.03; I² = 0%; 4 studies; 720 participants; low certainty evidence). We are uncertain whether integrated-valve technology reduces PICC-related BSI risk (RR 0.51, 95% CI 0.19 to 1.32; I² = not applicable; 2 studies (no events in 1 study); 542 participants) or catheter breakage, as the certainty of evidence is very low (RR 1.05, 95% CI 0.22 to 5.06; I² = 20%; 4 studies; 799 participants). Anti-thrombogenic surface modification compared to no anti-thrombogenic surface modification for peripherally inserted central catheter design We are uncertain whether use of anti-thrombogenic surface modified catheters reduces risk of VTE (RR 0.67, 95% CI 0.13 to 3.54; I² = 15%; 2 studies; 257 participants) or PICC-associated BSI, as the certainty of evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces occlusion (RR 0.69, 95% CI 0.04 to 11.22; I² = 70%; 2 studies; 257 participants) or all-cause mortality risk, as the certainty of evidence is very low (RR 0.49, 95% CI 0.05 to 5.26; I² = not applicable; 1 study; 111 participants). Use of anti-thrombogenic surface modified catheters may make little or no difference to risk of catheter failure (RR 0.76, 95% CI 0.37 to 1.54; I² = 46%; 2 studies; 257 participants; low certainty evidence). No PICC-related BSIs were reported in one study (111 participants). As such, we are uncertain whether use of anti-thrombogenic surface modified catheters reduces PICC-related BSI risk (RR not estimable; I² = not applicable; very low certainty evidence). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces the risk of catheter breakage, as the certainty of evidence is very low (RR 0.15, 95% CI 0.01 to 2.79; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Antimicrobial impregnation compared to non-antimicrobial impregnation for peripherally inserted central catheter design We are uncertain whether use of antimicrobial-impregnated catheters reduces VTE risk (RR 0.54, 95% CI 0.05 to 5.88; I² = not applicable; 1 study; 167 participants) or PICC-associated BSI risk, as the certainty of evidence is very low (RR 2.17, 95% CI 0.20 to 23.53; I² = not applicable; 1 study; 167 participants). Antimicrobial-impregnated catheters probably make little or no difference to occlusion risk (RR 1.00, 95% CI 0.57 to 1.74; I² = 0%; 2 studies; 1025 participants; moderate certainty evidence) or all-cause mortality (RR 1.12, 95% CI 0.71 to 1.75; I² = 0%; 2 studies; 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter failure (RR 1.04, 95% CI 0.82 to 1.30; I² = not applicable; 1 study; 221 participants; low certainty evidence). Antimicrobial-impregnated catheters probably make little or no difference to PICC-related BSI risk (RR 1.05, 95% CI 0.71 to 1.55; I² = not applicable; 2 studies (no events in 1 study); 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter breakage (RR 0.86, 95% CI 0.19 to 3.83; I² = not applicable; 1 study; 804 participants; low certainty evidence). AUTHORS' CONCLUSIONS: There is limited high-quality RCT evidence available to inform clinician decision-making for PICC materials and design. Limitations of the current evidence include small sample sizes, infrequent events, and risk of bias. There may be little to no difference in the risk of VTE, PICC-associated BSI, occlusion, or mortality across PICC materials and designs. Further rigorous RCTs are needed to reduce uncertainty.


Subject(s)
Catheter-Related Infections , Catheterization, Peripheral , Equipment Design , Equipment Failure , Randomized Controlled Trials as Topic , Venous Thromboembolism , Humans , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Catheter-Related Infections/prevention & control , Venous Thromboembolism/prevention & control , Venous Thromboembolism/etiology , Catheter Obstruction , Central Venous Catheters/adverse effects , Cause of Death , Bias , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/instrumentation , Bacteremia/prevention & control , Bacteremia/etiology
4.
Cochrane Database Syst Rev ; 5: CD013023, 2024 05 23.
Article in English | MEDLINE | ID: mdl-38780138

ABSTRACT

BACKGROUND: Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail, requiring reinsertion. Dressings and securement devices maintain AC function and prevent complications such as infection. OBJECTIVES: To evaluate the effectiveness of peripheral AC dressing and securement devices to prevent failure and complications in hospitalised people. SEARCH METHODS: We searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL Plus up to 16 May 2023. We also searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform up to 16 May 2023. SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing different dressing and securement devices for the stabilisation of ACs in hospitalised people. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials for inclusion, extracted data, and assessed risk of bias using Cochrane's RoB 1 tool. We resolved disagreements by discussion, or by consulting a third review author when necessary. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included five RCTs with 1228 participants and 1228 ACs. All included studies had high risk of bias in one or more domains. We present the following four comparisons, with the remaining comparisons reported in the main review. Standard polyurethane (SPU) plus tissue adhesive (TA) compared with SPU: we are very uncertain whether use of SPU plus TA impacts rates of AC failure (risk ratio (RR) 0.44, 95% confidence interval (CI) 0.20 to 0.98; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Neither study (165 participants) reported catheter-related bloodstream infections (CRBSI), thus we are very uncertain whether SPU plus TA impacts on the incidence of CRBSI (very low-certainty evidence). It is very uncertain whether use of SPU plus TA impacts AC dislodgement risk (RR 0.54, 95% CI 0.03 to 9.62; I² = 44%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts AC occlusion rates (RR 1.20, 95% CI 0.37 to 3.91; I² = 3%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts rates of adverse events with few reported events across groups (RR 0.89, 95% CI 0.09 to 8.33; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Bordered polyurethane (BPU) compared to SPU: we are very uncertain whether use of BPU impacts rates of AC failure (RR 0.67, 95% CI 0.21 to 2.13; 1 study, 60 participants; very low-certainty evidence). BPU may make little or no difference to CRBSI compared to SPU (RR 3.05, 95% CI 0.12 to 74.45; I² = not applicable as 1 study (60 participants) reported 0 events; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to the risk of AC dislodgement compared with SPU (RR 0.75, 95% CI 0.17 to 3.22; I² = 0%; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to occlusion risk compared with SPU (RR 0.80, 95% CI 0.60 to 1.07; I² = 0%; 2 studies, 572 participants; low-certainty evidence). It is very uncertain whether BPU impacts on the risk of adverse events compared with SPU (RR 0.33, 95% CI 0.01 to 7.87; 1 study, 60 participants; very low-certainty evidence). SPU plus sutureless securement devices (SSD) compared to SPU: we are very uncertain whether SPU plus SSD impacts risk of AC failure compared with SPU (RR 0.78, 95% CI 0.40 to 1.52; I² = 0%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain if SPU plus SSD impacts CRBSI incidence rate with no events in both groups (2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of dislodgement (RR 0.14, 95% CI 0.01 to 2.57; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of AC occlusion (RR 1.94, 95% CI 0.50 to 7.48; I² = 38%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain whether SPU plus SSD impacts on the risk of adverse events (RR 1.94, 95% CI 0.19 to 20.24; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). Integrated securement dressings compared to SPU: integrated securement dressings may result in little or no difference in risk of AC failure compared with SPU (RR 1.96, 95% CI 0.80 to 4.84; 1 study, 105 participants; low-certainty evidence); may result in little or no difference in CRBSI incidence with no events reported (1 study, 105 participants; low-certainty evidence); may result in little or no difference in the risk of dislodgement (RR 0.33, 95% CI 0.04 to 3.04; 1 study, 105 participants; low-certainty evidence), may result in little or no difference in occlusion rates with no events reported (1 study, 105 participants; low-certainty evidence), and may result in little or no difference in the risk of adverse events (RR 0.35, 95% CI 0.01 to 8.45; 1 study, 105 participants; low-certainty evidence). AUTHORS' CONCLUSIONS: There is currently limited rigorous RCT evidence available about the relative clinical effectiveness of AC dressing and securement products. Limitations of current evidence include small sample size, infrequent events, and heterogeneous outcome measurements. We found no clear difference in the incidence of AC failure, CRBSI, or adverse events across AC dressing or securement products including SPU, BPU, SSD, TA, and integrated securement products. The limitations of current evidence means further rigorous RCTs are needed to reduce uncertainty around the use of dressing and securement devices for ACs.


Subject(s)
Bandages , Catheter-Related Infections , Catheterization, Peripheral , Polyurethanes , Randomized Controlled Trials as Topic , Humans , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Catheter-Related Infections/prevention & control , Bias , Equipment Failure
5.
J Adv Nurs ; 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38896020

ABSTRACT

Paediatric patients with complex or acute conditions may require a central venous access device, however, almost one-third of these devices have associated complications (e.g. infections). Implementation of evidence-based practices regarding central venous access devices can reduce and potentially prevent complications. AIMS: This scoping review aimed to explore recent interventional research in CVAD management through an implementation lens. DESIGN: This scoping review used the Arksey and O'Malley framework. Studies were included if they were written in English, published in 2012 to July 2023, involved children and were relevant to the study aims. Risk of bias was appraised by the Mixed Methods Appraisal Tool. DATA SOURCES: Searches were undertaken in EMBASE, CINAHL (Ebsco), PubMed, Web of Science and Cochrane Library (CENTRAL). RESULTS: Of the 1769 studies identified in a systematic search, 46 studies were included. Studies mostly focused on health professionals and central venous access device maintenance and had quantitative pre-post study designs. Adherence to implementation frameworks was lacking, with many studies employing quality improvement approaches. Implementation strategies were typically multipronged, using health-professional education, bundles and working groups. Bundle compliance and reductions in central line-associated bloodstream infections were the most featured outcomes, with most studies primarily focusing on effectiveness outcomes. CONCLUSION: Translation of evidence-based practices to the clinical setting is difficult and current adoption of implementation frameworks (apart from 'quality improvement') is limited. Implementation strategies are diverse and dependent on the local context, and study outcomes typically focus on the effectiveness of the physical intervention, rather than measuring the implementation effort itself. IMPLICATIONS FOR PATIENTS: Future intervention research requires a more uniform and deliberate application of implementation frameworks and strategies. IMPACT: Greater exploration of relationships between frameworks and strategies and implementation and service outcomes is required to increase understanding of their role in maximizing resources to improve health care. Adhered to best reporting guidelines as per PRISMA-ScR (Tricco et al., 2018). PATIENT OR PUBLIC CONTRIBUTION: No patient or public contribution.

6.
J Adv Nurs ; 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38468151

ABSTRACT

BACKGROUND: Hospital-acquired pressure injuries (HAPIs) pose significant challenges in healthcare and cause increased patient suffering, longer hospital stays, and higher healthcare costs. Paediatric patients face unique risks, but evidence remains scarce. This study aimed to identify and describe HAPI admission incidence and severity predictors in a large Australian children's hospital. METHODS: This retrospective cohort study investigated all paediatric patients between January 2020 and December 2021 using a census approach. Demographic and clinical data including HAPI-related data were accessed from the incident monitoring and hospital administration databases. The incidence rate (per 1000 patient admissions) was calculated based on all admissions. Predictors of HAPI severity were identified using multivariable multinomial logistic regression. The study adhered to the STROBE guidelines for retrospective cohort studies. RESULTS: The HAPI incidence rate was 6.96 per 1000 patient admissions. Of the age groups, neonates had the highest HAPI incidence (15.5 per 1000 admissions). Critically ill children had the highest rate for admission location (12.8 per 1000 patient admissions). Most reported cases were stage I (64.2%). Age was associated with injury severity, with older paediatric patients more likely to develop higher-stage HAPIs. Additionally, Aboriginal and/or Torres Strait Islander patients had a higher HAPI severity risk. CONCLUSION: HAPI injuries in paediatric patients are unacceptably high. Prevention should be prioritized, and the quality of care improved in Australia and beyond. Further research is needed to develop targeted prevention strategies for these vulnerable populations. IMPLICATIONS FOR THE PROFESSION AND PATIENT CARE: This research emphasizes the need for standardized reporting, culturally sensitive care and tailored prevention strategies. IMPACT: The research has the potential to influence healthcare policies and practices, ultimately enhancing the quality of patient care. REPORTING METHOD: STROBE guidelines. NO PATIENT OR PUBLIC CONTRIBUTION: There was no patient or public contribution to the conduct of this study.

7.
J Clin Nurs ; 33(5): 1762-1776, 2024 May.
Article in English | MEDLINE | ID: mdl-38413831

ABSTRACT

BACKGROUND: Healthcare consumers require diverse resources to assist their navigation of complex healthcare interactions, however, these resources need to be fit for purpose. AIM: In this study, we evaluated the utility, usability and feasibility of children, families and adults requiring long-term intravenous therapy using a recently developed mobile health application (App), intravenous (IV) Passport. DESIGN: Multi-site, parallel, multi-method, prospective cohort study. METHODS: A multi-site, multi-method study was carried out in 2020-2021, with 46 participants (20 adults, 26 children/family) reporting on their experiences surrounding the use of the IV Passport for up to 6 months. RESULTS: Overall, utility rates were acceptable, with 78.3% (N = 36) using the IV Passport over the follow-up period, with high rates of planned future use for those still active in the project (N = 21; 73%), especially in the child/family cohort (N = 13; 100%). Acceptability rates were high (9/10; IQR 6.5-10), with the IV Passport primarily used for documenting new devices and complications. Thematic analysis revealed three main themes (and multiple subthemes) in the qualitative data: Advocacy for healthcare needs, Complexity of healthcare and App design and functionality. CONCLUSION: Several recommendations were made to improve the end-user experience including 'how to' instructions; and scheduling functionality for routine care. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: The IV Passport can be safely and appropriately integrated into healthcare, to support consumers. IMPACT: Patient-/parent-reported feedback suggests the Intravenous Passport is a useful tool for record-keeping, and positive communication between patients/parents, and clinicians. REPORTING METHOD: Not applicable. PATIENT CONTRIBUTION: Consumers reported their experiences surrounding the use of the IV Passport for up to 6 months.


Subject(s)
Telemedicine , Adult , Child , Humans , Prospective Studies , Telemedicine/methods , Delivery of Health Care , Parents , Communication
8.
J Pediatr Nurs ; 76: 68-75, 2024.
Article in English | MEDLINE | ID: mdl-38364591

ABSTRACT

PURPOSE: Children with chronic and complex health conditions frequently need intravenous devices. The current approach to intravenous device selection, insertion, and monitoring is inconsistent, and healthcare consumers are often negatively affected by siloed health information, and poor future planning. Despite child- and family-centred care being recognised as a pillar of paediatric nursing care, limited implementation for vascular access device planning and management is evident. DESIGN AND METHODS: To address this, we conducted a multi-phased approach to co-create, then evaluate, a mobile health (mHealth) application: IV Passport. Co-creation involved a prioritisation survey, followed by a Passport advisory panel consensus meeting. Following confirmation of the required content and features of the Passport, the mHealth application was designed and content validation achieved via survey. RESULTS: The prioritisation survey yielded recommendations for seven features (e.g., graphical presentations of current/past devices). Content for nine device types (e.g., totally implanted ports) was suggested, each with 10 related items (e.g., insertion site). Content items for device-associated complications, future vascular access plans, and educational resources were also suggested. Following design, the application was released through Apple and Android platforms; and adapted to a paper version. Content validation was established; 100% strongly agreed the application was easy to use; 80% agreed/strongly agreed that they would recommend the Passport to others. CONCLUSION: IV Passport embodies effective child- and family-centred care through consumer co-creation to empower patients and families manage vascular access devices. PRACTICE IMPLICATIONS: IV Passport remains active; and can be utilised across many healthcare settings and patient populations.


Subject(s)
Telemedicine , Vascular Access Devices , Humans , Child , Mobile Applications , Male , Female , Chronic Disease , Pediatric Nursing
9.
Aust Crit Care ; 37(1): 34-42, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38142148

ABSTRACT

BACKGROUND: Endotracheal suction is used to maintain endotracheal tube patency. There is limited guidance to inform clinical practice for children with respiratory infections. OBJECTIVE: The objective of this study was to determine whether implementation of a paediatric endotracheal suction appropriate use guideline Paediatric AirWay Suction (PAWS) is associated with an increased use of appropriate and decreased use of inappropriate suction interventions. METHODS: A mixed-method, pre-implementation-post-implementation study was conducted between September 2021 and April 2022. Suction episodes in mechanically ventilated children with a respiratory infection were eligible. Using a structured approach, we implemented the PAWS guideline in a single paediatric intensive care unit. Evaluation included clinical (e.g., suction intervention appropriateness), implementation (e.g., acceptability), and cost outcomes (implementation costs). Associations between implementation of the PAWS guideline and appropriateness of endotracheal suction intervention use were investigated using generalised linear models. RESULTS: Data from 439 eligible suctions were included in the analysis. Following PAWS implementation, inappropriate endotracheal tube intervention use reduced from 99% to 58%, an absolute reduction (AR) of 41% (95% confidence interval [CI]: 25%, 56%). Reductions were most notable for open suction systems (AR: 48%; 95% CI: 30%, 65%), 0.9% sodium chloride use (AR: 23%; 95% CI: 8%, 38%) and presuction and postsuction manual bagging (38%; 95% CI: 16%, 60%, and 86%; 95% CI: 73%, 99%), respectively. Clinicians perceived PAWS as acceptable and suitable for use. CONCLUSIONS: Implementation of endotracheal tube suction appropriate use guidelines in a mixed paediatric intensive care unit was associated with a large reduction in inappropriate suction intervention use in paediatric patients with respiratory infections.


Subject(s)
Respiration, Artificial , Respiratory Tract Infections , Child , Humans , Suction/methods , Intubation, Intratracheal/adverse effects , Sodium Chloride
10.
Pediatr Res ; 93(1): 160-167, 2023 01.
Article in English | MEDLINE | ID: mdl-35411069

ABSTRACT

BACKGROUND: Our study aims to explore the experience of having a central venous access device (CVAD) from the perspective of the child and family and how movements within and outside of hospital environments influence this experience. METHODS: A mixed-methods study was conducted across Children's Health Queensland (Australia), including inpatient and home-care settings. Children less than 18 years with CVADs were eligible and followed for 3 months or CVAD removal. A subgroup of primary caregivers participated in semi-structured interviews. Quantitative and qualitative measures of child and family CVAD experiences were explored. RESULTS: In total, 163 patients with 200 CVADs were recruited and followed for 6993 catheter days (3329 [48%] inpatients; 3147 [45%] outpatients; 517 [7%] home). Seventeen participants were interviewed. Experiences of having a CVAD were complex but predominantly positive primarily related to personalized CVAD care, healthcare quality, and general wellbeing. Their experience was shaped by their movements through hospital and home environments, including care variation and distress with procedures. Device selection and insertion location further influenced experience, including safety, impairments in activities of daily living, school, and recreation. CONCLUSIONS: CVAD experiences were influenced by nonmodifiable (e.g., diagnosis) and modifiable factors (e.g., education; care variation). Clinical approaches and policies that account for family and child considerations should be explored. IMPACT: Variation in decision making and management for pediatric CVADs is accepted by many clinicians, but the influence this variation has on the health experience of children and their families is less well explored. This is the first study to draw from a broad range of children requiring CVADs to determine their experience within and outside of healthcare facilities. Interdisciplinary clinicians and researchers need to work collaboratively with children and their families to provide resources and support services to ensure they have positive experiences with CVADs, no matter where they are managed, or who they are managed by.


Subject(s)
Catheterization, Central Venous , Central Venous Catheters , Home Care Services , Humans , Child , Activities of Daily Living , Australia , Educational Status
11.
BMC Health Serv Res ; 23(1): 587, 2023 Jun 07.
Article in English | MEDLINE | ID: mdl-37286977

ABSTRACT

BACKGROUND: Peripheral intravenous catheters (PIVCs) are the most used invasive medical device in healthcare. Yet around half of insertion attempts are unsuccessful leading to delayed medical treatments and patient discomfort of harm. Ultrasound-guided PIVC (USGPIVC) insertion is an evidence-based intervention shown to improve insertion success especially in patients with Difficult IntraVenous Access (BMC Health Serv Res 22:220, 2022), however the implementation in some healthcare settings remains suboptimal. This study aims to co-design interventions that optimise ultrasound guided PIVC insertion in patients with DIVA, implement and evaluate these initiatives and develop scale up activities. METHODS: A stepped-wedge cluster randomized controlled trial will be conducted in three hospitals (two adult, one paediatric) in Queensland, Australia. The intervention will be rolled out across 12 distinct clusters (four per hospital). Intervention development will be guided by Michie's Behavior Change Wheel with the aim to increase local staff capability, opportunity, and motivation for appropriate, sustainable adoption of USGPIVC insertion. Eligible clusters include all wards or departments where > 10 PIVCs/week are typically inserted. All clusters will commence in the control (baseline) phase, then, one cluster per hospital will step up every two months, as feasible, to the implementation phase, where the intervention will be rolled out. Implementation strategies are tailored for each hospital by local investigators and advisory groups, through context assessments, staff surveys, and stakeholder interviews and informed by extensive consumer interviews and consultation. Outcome measures align with the RE-AIM framework including clinical-effectiveness outcomes (e.g., first-time PIVC insertion success for DIVA patients [primary outcome], number of insertion attempts); implementation outcomes (e.g., intervention fidelity, readiness assessment) and cost effectiveness outcomes. The Consolidated Framework for Implementation Research framework will be used to report the intervention as it was implemented; how people participated in and responded to the intervention; contextual influences and how the theory underpinning the intervention was realised and delivered at each site. A sustainability assessment will be undertaken at three- and six-months post intervention. DISCUSSION: Study findings will help define systematic solutions to implement DIVA identification and escalation tools aiming to address consumer dissatisfaction with current PIVC insertion practices. Such actionable knowledge is critical for implementation of scale-up activities. TRIAL REGISTRATION: Prospectively registered (Australian and New Zealand Clinical Trials Registry; ACTRN12621001497897).


Subject(s)
Hospitals , Technology , Adult , Humans , Child , Australia , Queensland , Treatment Outcome , Randomized Controlled Trials as Topic
12.
Cardiol Young ; : 1-7, 2023 Nov 06.
Article in English | MEDLINE | ID: mdl-37927298

ABSTRACT

BACKGROUND: CHD is associated with considerable burden of care. Up to one-third of babies born with CHD require surgery or intervention during the first year of life with an associated increased risk of surgical site infection. Pediatric wound care is informed largely by adult data, with no national or international guidelines available. AIM: To examine pediatric cardiac surgical wound care practices reported by healthcare professionals Australia and New Zealand-wide. METHODS: A bi-national cross-sectional survey exploring pre-, intra- and post-operative wound practices was distributed using Exponential Non-Discriminative Snowball Sampling. Data were subject to descriptive analysis using SPSS Statistics 22.0. FINDINGS: Sixty-eight surveys representing all Australian and New Zealand pediatric cardiac surgical services were analyzed. Most respondents were experienced nurses. Pre-operative care varied greatly in practice and pharmaceutical agents used. Little consistency was reported for intra- and post-operative wound care. Nursing and medical staff shared responsibility for wound care. Wound photography was widely used, but only uploaded to electronic medical records by some. DISCUSSION: These results highlight that wound care management is largely informed at an institutional level. The many practices reported are likely to reflect a range of factors including cardiac condition complexity, surgery, prematurity, and the presence of scar tissue. The importance of a research and training program, which is multimodal, available, and reflective, is highlighted. CONCLUSION: These findings call for the establishment of a nurse-led program of research and education. The resultant suite of cardiac wound strategies could offer an effective and consistent pathway forward.

13.
J Adv Nurs ; 2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38037540

ABSTRACT

AIM: This qualitative study aimed to identify nurses' and allied health professionals' perceptions and experiences of providing hospital-acquired pressure injury (HAPI) prevention in a paediatric tertiary hospital in Australia, as well as understand the perceived barriers and facilitators to preventing HAPI. DESIGN: A qualitative, exploratory study of hospital professionals was undertaken using semi-structured interviews between February 2022 and January 2023. METHODS: Two frameworks, the Capability, Opportunity and Motivation Model of Behaviour (COM-B) and the Theoretical Domains Framework (TDF), were used to give both theoretical and pragmatic guidance. Participants included 19 nursing and allied health professionals and data analysis was informed by the framework approach. RESULTS: Analysis revealed nine core themes regarding professionals' beliefs about the barriers and facilitators to HAPI prevention practices across seven TDF domains. Themes included HAPI prevention skills and education, family-centred care, automated feedback and prompts, allocation and access to equipment, everybody's responsibility, prioritizing patients and clinical demands, organizational expectations and support, integrating theory and reality in practice and emotional influence. CONCLUSION: These findings provide valuable insights into the barriers and facilitators that impact paediatric HAPI prevention and can help identify and implement strategies to enhance evidence-based prevention care and prevent HAPI in paediatric settings. IMPACT: Overcoming barriers through evidence-based interventions is essential to reduce HAPI cases, improve patient outcomes, and cut healthcare costs. The findings have practical implications, informing policy and practice for improved preventive measures, education, and staffing in paediatric care, ultimately benefiting patient well-being and reducing HAPIs. PATIENT OR PUBLIC CONTRIBUTION: No patient or public contribution. The focus of the study is on healthcare professionals and their perspectives and experiences in preventing HAPIs in paediatric patients. Therefore, the involvement of patients or the public was not deemed necessary for achieving the specific research objectives.

14.
J Clin Nurs ; 32(9-10): 1841-1857, 2023 May.
Article in English | MEDLINE | ID: mdl-35118759

ABSTRACT

AIM: To synthesise evidence related to medical adhesive tapes and supplementary securement products for peripheral intravenous catheters in adults, to prevent complications and device failure. DESIGN: Integrative review informed by Whittemore and Knafl and reported in accordance with the PRISMA 2020 statement. DATA SOURCES: The Cochrane Central Register of Controlled Trials, US National Library of Medicine National Institutes of Health, EMBASE/MEDLINE and Cumulative Index to Nursing and Allied Health were searched from 2000-21 September 2020. REVIEW METHODS: Studies enrolling hospitalised participants >16 years with peripheral intravenous catheters secured by medical adhesive tapes, or supplementary products (bandage, splint and sutureless securement device), were eligible. Quality appraisal was performed using Critical Appraisal Skills Program checklists. RESULTS: Nineteen studies met criteria, including 43,683 peripheral intravenous catheters. Quality appraisal identified high or unclear risk of bias in 58% of studies. Nonsterile tape was the most common intervention tested (14 studies), alone or in multiproduct combinations. Nonsterile tape directly over insertion sites was associated with increased PIVC failure and complications. Sutureless securement devices potentially reduce failure and complications. Multiproduct combinations were very common. Practice recommendations regarding other tapes and secondary securement products are challenging, due to conflicting, or lack of, evidence. CONCLUSION: Tapes and secondary securement product evidence are limited, and over half of the studies are of low methodological quality. This review found nonsterile tape was associated with increased failure and complications; multiproduct dressing and securement bundles were prevalent; and significant evidence gaps exist particularly regarding bandages and splints. The results provide nurses with evidence of medical adhesive tapes and supplementary product effectiveness for peripheral intravenous catheter securement, and future research directions to reduce unacceptably high failure and complication rates. Larger rigorously conducted randomised controlled trials are needed to add to current evidence.


Subject(s)
Bandages , Catheterization, Peripheral , Adult , Humans , Catheters, Indwelling , Adhesives , Catheterization, Peripheral/methods
15.
J Clin Nurs ; 32(17-18): 6690-6705, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37204006

ABSTRACT

AIMS AND OBJECTIVES: Explore the parent and child/young person experience of difficult venous access and identify ideas and preferences for changes to clinical practice. BACKGROUND: Peripheral intravenous catheter insertion is one of the most common invasive procedures in hospitalised paediatric patients. Multiple insertion attempts in paediatric patients are common and associated with pain and distress. Little research has explored the parent and child/young person experience of difficult venous access nor sought to identify their suggestions to improve clinical practice. DESIGN: Qualitative description. METHODS: A purposive sampling approach was used to identify children and young people with experience of difficult venous access and their parents. Semi-structured interviews were conducted, with sample size based on data saturation. Transcripts were analysed using thematic analysis. RESULTS: There were 12 participants, seven parents and five children/young people (five parent/child dyads and two individual parents). Analysis of the data revealed three main themes: (1) Distress-before, during and after (2) Families navigating the system: the challenging journey from general clinician to specialist and (3) Difficult venous access impacts both treatment and life outside the hospital A pre-determined theme, (4) Recommendations for good clinical practice is also described. CONCLUSIONS: Multiple attempts to insert a peripheral intravenous catheter are a source of substantial distress for children/young people, leading to treatment avoidance. Effective interpersonal skills, providing choice and avoiding frightening language are important to minimise distress. Clinicians without specialist training should assess each child's venous access experience and consider immediate referral to a specialist if they have a history of difficult venous access. Cultural change is required so clinicians and healthcare services recognise that repeated cannulation may be a source of psychological distress for children/young people.


Subject(s)
Pain , Parents , Child , Humans , Adolescent , Parents/psychology , Qualitative Research , Fear
16.
J Clin Nurs ; 32(17-18): 6706-6722, 2023 Sep.
Article in English | MEDLINE | ID: mdl-36970881

ABSTRACT

AIMS: The aim of this study was to critically evaluate implementation frameworks, strategies and/or outcomes used to optimise peripheral intravenous catheter (PIVC) care and/or promote guideline adherence. BACKGROUND: Although a considerable volume of research has investigated the effectiveness of PIVC interventions and treatments to promote performance and prevent harm, how to best implement this evidence into dynamic clinical settings and populations is not well understood. Implementation science is central to translating evidence-based knowledge to the bedside; however, there is a gap in identifying the best implementation framework, strategies and/or outcomes to optimise PIVC care and/or guideline adherence. DESIGN: A systematic review. METHOD: The review was conducted using innovative automation tools. Five databases and clinical trial registries were searched on 14 October 2021. Qualitative and quantitative PIVC intervention studies reporting implementation strategies were included in the review. Data were extracted independently by experienced researchers in pairs. The Mixed Method Appraisal tool was used to assess the quality of individual studies. Narrative synthesis was used to present the findings. The systematic review was reported following the PRISMA checklist. RESULTS: Of 2189 references identified, 27 studies were included in the review. Implementation frameworks were used in 30% (n = 8) of studies, with most used during the preparation (n = 7, 26%) and delivery phase (n = 7, 26%) and then evaluation phase (n = 4, 15%). Multifaceted strategies were commonly adopted (n = 24, 89%) to promote PIVC care or study interventions which were clinician (n = 25, 93%) and patient-targeted (n = 15, 56%). The most commonly reported implementation outcomes were fidelity (n = 13, 48%) and adoption (n = 6, 22%). Most studies were scored as low quality (n = 18, 67%). CONCLUSION: We call for researchers and clinicians to work together and use implementation science frameworks to guide study design, implementation and evaluation in future PIVC studies, to improve evidence translation and thereby improve patient outcomes.


Subject(s)
Catheterization, Peripheral , Catheters , Humans
17.
Article in English | MEDLINE | ID: mdl-38099826

ABSTRACT

BACKGROUND: Implementing family-centered care (FCC) presents challenges to parental-healthcare provider partnership and collaboration in newborn care in neonatal intensive care units (NICUs). AIMS: To explore NICU nurses' perceptions of FCC (respect, collaboration, and support) during the COVID-19 pandemic and to compare these between nurses working in secondary and tertiary/higher care settings. METHODS: A multicenter, cross-sectional exploratory online survey design study was conducted to identify Thai NICU nurses' perceptions. The online survey of the Perceptions of Family-Centered Care-Staff (PFCC-S) was distributed via a Web page and professional networks between July and September 2022. RESULTS: Of the 187 survey respondents, most NICU nurses worked in the NICU for less than 16 years and were employed in tertiary care/higher care settings in southern Thailand. There was a significant difference in perceptions of support subscale between NICU nurses in secondary (mean: 3.32, SD ± 0.53) and tertiary/higher care settings (mean: 3.17, SD ± 0.46) (P < .05). CONCLUSION: Despite the challenges of the visitation restriction of COVID-19 in Thailand, nurses' perceptions of the value of FCC were maintained. RELEVANCE TO CLINICAL PRACTICE: Further research is recommended to investigate how FCC can be implemented where there is a lack of material and infrastructure resources and staff shortage.

18.
Nurs Crit Care ; 28(1): 47-55, 2023 01.
Article in English | MEDLINE | ID: mdl-34545671

ABSTRACT

BACKGROUND: Family-centered care (FCC) has been successfully incorporated into daily practice in many neonatal intensive care units (NICUs) worldwide. However, the implementation of FCC in lower-resourced settings, such as Thailand, can be challenging and needs to be further explored. AIMS: To identify parents' and interdisciplinary professionals' perceptions of FCC and to describe the opportunities to improve FCC in a Thai NICU. DESIGN: An exploratory qualitative approach was used. METHODS: The data were collected through face-to-face, semi-structured, individual interviews based on an interview guide. This study was conducted before the outbreak of coronavirus disease 2019 (February 2020) in a hospital in southern Thailand. Inductive thematic analysis was used to analyse interview data. RESULTS: Participants were parents (n = 9) and interdisciplinary professionals (n = 8). The results revealed four key themes: (a) Recognizing and responding to individual families' different readiness and their rights and values, (b) working in a parent-interdisciplinary partnership to provide care, (c) lacking resources and motivation and (d) understanding of care requirements and providing help/sympathy. CONCLUSIONS: The interdisciplinary professionals accepted that FCC is necessary for clinical practice, but there are some challenges in the Thai NICUs context because of the system of health care delivery. The findings highlighted that interdisciplinary professionals often viewed parents' involvement as an obstacle to providing neonatal care. RELEVANCE TO CLINICAL PRACTICE: Further research is recommended to investigate how FCC is operationalized by interdisciplinary professionals and how hospital administrators can be supported to implement the FCC approach into clinical practice in Thai NICUs.


Subject(s)
COVID-19 , Intensive Care Units, Neonatal , Infant, Newborn , Humans , Southeast Asian People , Thailand , COVID-19/epidemiology , Parents , Qualitative Research , Patient-Centered Care/methods
19.
Aust Crit Care ; 36(6): 1129-1137, 2023 11.
Article in English | MEDLINE | ID: mdl-36635184

ABSTRACT

OBJECTIVES: The objective of this study was to critically appraise and synthesise evidence for blood conservation strategies in intensive care. Blood sampling is a critical aspect of intensive care to guide clinical decision-making. Repeated blood sampling can result in blood waste and contamination, leading to iatrogenic anaemia and systemic infection. REVIEW METHOD USED: Cochrane systematic review methods were used including meta-analysis, and independent reviewers. DATA SOURCES: A systematic search was conducted in Medline, CINAHL, PUBMED and EMBASE databases. The search was limited to randomised controlled trials (RCTs) and cluster RCTs, published in English between 2000 and 2021. REVIEW METHODS: Paired authors independently assessed database search results and identified eligible studies. Trials comparing any blood conservation practice or product in intensive care were included. Primary outcomes were blood sample volumes and haemoglobin change. Secondary outcomes included proportion of patients receiving transfusions and infection outcomes. Quality appraisal employed the Cochrane Risk of Bias tool. Meta-analysis using random effects approach and narrative synthesis summarised findings. RESULTS: Eight studies (n = 1027 patients), all RCTs were eligible. Six studies included adults, one studied paediatrics and one studied preterm infants. Seven studies evaluated a closed loop blood sampling system, and one studied a conservative phlebotomy protocol. Studies were of low to moderate quality. Meta-analysis was not possible for interventions targeting blood sample volumes or haemoglobin. Decreased blood sample volumes reported in four studies were attributable to a closed loop system or conservative phlebotomy. No study reported a significant change in haemoglobin. Meta-analysis demonstrated that use of a closed system (compared to open system) reduced the proportion of patients receiving transfusion [Risk Ratio (RR) 0.65, 95% CI 0.46-0.92; 287 patients] and reduced intraluminal fluid colonisation [RR 0.25, 95% CI 0.07-0.58; 500 patients]. CONCLUSIONS: Limited evidence demonstrates closed loop blood sampling systems reduced transfusion use and fluid colonisation. Simultaneous effectiveness-implementation evaluation of these systems and blood conservation strategies is urgently required. PROSPERO PROTOCOL REGISTRATION REFERENCE: CRD42019137227.


Subject(s)
Critical Care , Infant, Premature , Infant, Newborn , Adult , Humans , Child , Hemoglobins
20.
Aust Crit Care ; 36(2): 201-207, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35221230

ABSTRACT

OBJECTIVE: The objective of this study was to audit current patient blood management practice in children throughout cardiac surgery and paediatric intensive care unit (PICU) admission. DESIGN: This was a prospective observational cohort study. SETTING: This was a single-centre study in the cardiac operating room (OR) and PICU in a major tertiary children's hospital in Australia. PATIENTS: Children undergoing corrective cardiac surgery and requiring admission to PICU for postoperative recovery were included in the study. MEASUREMENTS AND MAIN RESULTS: Fifty-six patients and 1779 blood sampling episodes were audited over a 7-month period. The median age was 9 months (interquartile range [IQR] = 1-102), with the majority (n = 30 [54%]) younger than 12 months. The median number of blood sampling episodes per patient per day was 6.6 (IQR = 5.8-8.0) in total, with a median of 5.0 (IQR = 4.0-7.5) episodes in the OR and 5.0 (IQR = 3.4-6.2) episodes per day throughout PICU admission. The most common reason for blood tests across both OR and PICU settings was arterial blood gas analysis (total median = 86%, IQR = 79-96). The overall median blood sampling volume per kg of bodyweight, patient, and day was 0.63 mL (IQR = 0.20-1.14) in total. Median blood loss for each patient was 3.5 mL/kg per patient per day (IQR = 1.7-5.6) with negligible amounts in the OR and a median of 3.6 mL/kg (IQR = 1.7-5.7) in the PICU. The median Cell Saver® transfusion volume was 9.9 mL/kg per patient per day (IQR = 4.0-19.1) in the OR. The overall median volume of other infusion products (albumin 4%, albumin 20%, packed red blood cells) received by each patient was 20.1 mL/kg (IQR = 10.7-36.4) per day. Sampling events and blood loss were positively associated with PICU stay. CONCLUSIONS: Patient blood management practices observed in this study largely conform to National Blood Authority guidelines. Further implementation projects and research are needed to accelerate implementation of known effective blood conservation strategies within paediatric critical care environments.


Subject(s)
Cardiac Surgical Procedures , Critical Illness , Child , Humans , Infant , Cohort Studies , Prospective Studies , Intensive Care Units, Pediatric , Blood Transfusion
SELECTION OF CITATIONS
SEARCH DETAIL