Clin Transplant ; 38(4): e15296, 2024 04.
Article in English | MEDLINE | ID: mdl-38545928

ABSTRACT

INTRODUCTION: Clinical success of donation after circulatory death (DCD) heart transplantation is leading to growing adoption of this technique. In comparison to procurement from a brain-dead donor, DCD requires additional resources. The economic impact of DCD heart transplantation from the hospital perspective is not well known. METHODS: We compared the financial data of patients who received DCD allografts to those who received a DBD organ at our institution from January 1, 2021 to December 31, 2022. We also compared the cost of ex-situ machine perfusion to in-situ organ perfusion employed during DCD recovery. RESULTS: We performed 58 DBD and 22 DCD heart-alone transplantations during the study period. Out of 22 DCD grafts, 16 were recovered with thoracoabdominal normothermic regional perfusion (TA-NRP) and six with direct procurement followed by normothermic machine perfusion (DP-NMP). The contribution margin per case for DBD versus DCD was $234,362 and $235,440 (P = .72). The direct costs did not significantly differ between the two groups ($171,949 and 186,250; P = .49). In comparing the two methods of procuring hearts from DCD donors, the direct cost of TA-NRP was $155,955 in comparison to $223,399 for DP-NMP (P = .21). This difference translated into a clinically meaningful but not statistically significant greater contribution margin for TA-NRP ($242, 657 vs. $175,768; P = .34). CONCLUSIONS: Our data showed that the adoption of DCD procurement did not have a negative financial impact on the contribution margin in our institution. Programs considering starting DCD heart transplantation, and those who are currently performing DCD procurement should evaluate their own financial situation.


Subject(s)
Heart Transplantation , Tissue and Organ Procurement , Humans , Heart Transplantation/methods , Tissue Donors , Perfusion/methods , Brain Death , Death , Organ Preservation/methods , Graft Survival
2.
Article in English | MEDLINE | ID: mdl-38367698

ABSTRACT

OBJECTIVES: The HeartMate 3 (Abbott) left ventricular assist device provides substantial improvement in long-term morbidity and mortality in patients with advanced heart failure. The Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study compares thoracotomy-based implantation clinical outcomes with standard median sternotomy. METHODS: We conducted a prospective, multicenter, single-arm study in patients eligible for HeartMate 3 implantation with thoracotomy-based surgical technique (bilateral thoracotomy or partial upper sternotomy with left thoracotomy). The composite primary end point was survival free of disabling stroke (modified Rankin score >3), or reoperation to remove or replace a malfunctioning device, or conversion to median sternotomy at 6-months postimplant (elective transplants were treated as a success). The primary end point (noninferiority, -15% margin) was assessed with >90% power compared with a propensity score-matched cohort (ratio 1:2) derived from the Multi-Center Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 continued access protocol. RESULTS: The study enrolled 102 patients between December 2020 and July 2022 in the thoracotomy-based arm at 23 North American centers. Follow-up concluded in December 2022. In the Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study group, noninferiority criteria was met (absolute between-group difference, -1.2%; Farrington Manning lower 1-sided 95% CI, -9.3%; P < .0025) and event-free survival was not different (85.0% vs 86.2%; hazard ratio, 1.01; 95% CI, 0.58-2.10). Length of stay with thoracotomy-based implant was longer (median, 20 vs 17 days; P = .03). No differences were observed for blood product utilization, adverse events (including right heart failure), functional status, and quality of life between cohorts. CONCLUSIONS: Thoracotomy-based implantation of the HeartMate 3 left ventricular assist device is noninferior to implantation via standard full sternotomy. This study supports thoracotomy-based implantation as an additional standard for surgical implantation of the HeartMate 3 left ventricular assist device.

SELECTION OF CITATIONS
SEARCH DETAIL