Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Ophthalmic Physiol Opt ; 44(1): 124-130, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37974449

ABSTRACT

PURPOSE: To assess the reliability and agreement of non-invasive break-up time (NIBUT) in symptomatic and asymptomatic contact lens (CL) wearers using automatic objective and conventional subjective techniques. METHODS: In this prospective cross-sectional study, soft CL wearers, classified into symptomatic and asymptomatic based on the Contact Lens Dry Eye Questionnaire-8, underwent NIBUT assessment with the CL in situ. The CA-800 Corneal Analyzer and the EasyTear® VIEW+ Tearscope were used for objective and subjective evaluation, respectively. The within-subject repeatability and intraclass correlation coefficient (ICC) were calculated. The agreement between the devices was compared using the Bland-Altman method. RESULTS: A total of 141 CL wearers (51 male and 90 female) with a mean age of 33.6 (SD = 12.2) years were included. The repeatability and ICC values obtained with the CA-800 device when measuring NIBUT were 5.4 s and 58.6% across the whole sample, 4.2 s and 48.8% for the asymptomatic group and 7.1 s and 68.4% for the symptomatic group. When using the subjective method (EasyTear®), the respective repeatability and ICC values were 7.3 s and 32.7% for the whole sample, 6.5 s and 30.4% for the asymptomatic group and 8.6 s and 35.9% for the symptomatic group. The CA-800 device provided significantly (p < 0.001) shorter NIBUT values compared with EasyTear® for the whole sample (3.3 [2.9] vs. 8.1 [3.4] s), the asymptomatic (3.3 [3.0] vs. 7.7 [3.6] s) and the symptomatic (3.8 [2.9] vs. 8.6 [3.0] s) groups. CONCLUSION: Objective (CA-800) NIBUT assessment provides more reliable measurements than the conventional subjective technique using the EasyTear® device. However, CL practitioners should also be aware that the objective method indicates shorter NIBUT values. Symptomatic CL wearers may also need a higher number of NIBUT measurements to obtain reliable estimations.


Subject(s)
Contact Lenses, Hydrophilic , Dry Eye Syndromes , Humans , Male , Female , Adult , Prospective Studies , Reproducibility of Results , Cross-Sectional Studies , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/etiology , Tears
2.
Eye Contact Lens ; 50(1): 29-34, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38124284

ABSTRACT

OBJECTIVE: The purpose of this study was to assess the visual performance and monochromatic higher-order aberrations (HOAs) obtained while wearing a MiSight dual-focus (DF) contact lenses (CL) in comparison with a single-vision contact lens (SVCL). METHODS: A randomized, double-masked, cross-over study was performed. Participants were fitted with a DFCL and a SVCL composed of the same material (omafilcon A) and parameters. Logarithm of the Minimum Angle of Resolution high-contrast (100%) and low-contrast (10%) visual acuity (VA) and contrast sensitivity (CS) for 3, 6, 12, and 18 cycles per degree were measured. Higher-order aberrations were also evaluated using a Hartmann-Shack aberrometer with the CLs on. RESULTS: Twenty-four subjects (21 females and 3 males) with a mean age of 21.9±1.9 years (range: 18-27) were included. Low-contrast VA was significantly lower with the DFCL regarding the SVCL design (0.39±0.23 vs 0.25±0.18, P=0.002). However, there were no differences in high-contrast VA between both CLs (-0.03±0.10 vs -0.09±0.14, P=0.187). Contrast sensitivity was lower with the DFCL under all spatial frequencies (P≤0.048). Second-, third-, fourth-, and fifth-order aberrations were significantly (P<0.001) higher for the DFCL. There were also significant differences between DFCL and SVCL in defocus (0.87±0.28 vs 0.16±0.35, P<0.001), oblique trefoil (-0.16±0.27 vs -0.01±0.08, P=0.005), vertical coma (0.13±0.17 vs 0.00±0.08, P=0.002), and spherical aberration (0.09±0.11 vs -0.02±0.05, P=0.002). CONCLUSION: Visual performance for detecting low-contrast targets is reduced when wearing MiSight DFCL compared with a SVCL with the same material. The main reason might be the induction of second-order and HOAs by the DFCL design.


Subject(s)
Contact Lenses, Hydrophilic , Contact Lenses , Adult , Female , Humans , Male , Young Adult , Contrast Sensitivity , Cross-Over Studies , Vision Disorders , Visual Acuity , Adolescent
3.
Cont Lens Anterior Eye ; 47(1): 102096, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38097423

ABSTRACT

PURPOSE: This study aimed to assess the subjective and objective differences among the steps of the contact lens discomfort (CLD) progression classification established by the Tear Film & Ocular Surface Society (TFOS) using questionnaires and clinical signs, and to propose a simplified classification. METHODS: Contact lens (CL) wearers were evaluated in a single visit. The Contact Lens Dry Eye Questionnaire (CLDEQ)-8, the Contact Lens Discomfort Index, and Visual Analog Scales for discomfort and dryness were administered. The non-invasive break-up time, the tear film lipid layer thickness, conjunctival hyperaemia and papillae, lid-parallel conjunctival folds, the fluorescein tear film break-up time, corneal and conjunctival staining, lid wiper epitheliopathy, and the Schirmer test were assessed. Sign and symptom scores were compared among TFOS CLD progression steps using analysis of variance or the Kruskal-Wallis H test. Steps 1 and 2 (reduced comfort), and steps 3 and 4 (reduced wearing time) of the TFOS classification were combined to obtain a simplified classification, and the same comparison was performed. A p-value ≤ 0.05 was considered statistically significant. RESULTS: One hundred-fifty CL wearers (97 women and 53 men) aged 34.4 ± 12.6 years were included. In the TFOS classification, there were significant differences between step 0 (no CLD) and the rest of the severity steps for the scores obtained in all questionnaires (p ≤ 0.015). All steps were differentiated (p ≤ 0.032) based on the simplified classification for all questionnaires, except steps 1 and 2 for the CLDEQ-8 and dryness VAS (p = 0.089 and p = 0.051, respectively). There were no differences (all p ≥ 0.06) between the sign scores among the steps of either classification. CONCLUSION: CLD management is encouraged from its first appearance. Simplifying the phases of CLD severity may allow a more accurate classification and a better awareness of the problem by clinicians and CL wearers by using more straightforward simple messages.


Subject(s)
Contact Lenses, Hydrophilic , Dry Eye Syndromes , Male , Humans , Female , Contact Lenses, Hydrophilic/adverse effects , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/etiology , Conjunctiva , Cornea , Tears
4.
Ocul Surf ; 31: 31-42, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38128761

ABSTRACT

PURPOSE: This study aimed to analyze the differences in the expression of pain-related genes in conjunctival epithelial cells among symptomatic contact lens (CL) wearers (SCLWs), asymptomatic CL wearers (ACLWs), and non-CL wearers (non-CLWs). METHODS: For this study, 60 participants (20 non-CLWs, 40 CLWs) were enrolled. The CLW group comprised 20 ACLWs and 20 SCLWs according to the Contact Lens Dry Eye Questionnaire short form©. Conjunctival cells were collected using impression cytology, and RNA was isolated and used to determine the expression levels of 85 human genes involved in neuropathic and inflammatory pain. The effects of CL wear and discomfort were evaluated using mixed-effects ANOVA with partially nested fixed-effects model. Gene set enrichment analysis was performed to assign biological meaning to sets of differentially expressed genes. RESULTS: Six genes (CD200, EDN1, GRIN1, PTGS1, P2RX7, and TNF) were significantly upregulated in CLWs compared to non-CLWs. Eleven genes (ADORA1, BDKRB1, CACNA1B, DBH, GRIN1, GRM1, HTR1A, PDYN, PTGS1, P2RX3, and TNF) were downregulated in SCLWs compared to ACLWs. These genes were mainly related to pain, synaptic transmission and signaling, ion transport, calcium transport and concentration, and cell-cell signaling. CONCLUSIONS: CL wear modified the expression of pain- and inflammation-related genes in conjunctival epithelial cells. These changes may be in part, along with other mechanisms, responsible for CL discomfort in SCLWs.


Subject(s)
Contact Lenses, Hydrophilic , Dry Eye Syndromes , Humans , Conjunctiva/metabolism , Epithelial Cells/metabolism , Dry Eye Syndromes/metabolism , Pain , Gene Expression
5.
Ocul Immunol Inflamm ; : 1-9, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38889385

ABSTRACT

PURPOSE: To analyze changes in tear levels of inflammatory mediators in symptomatic contact lens (CL) wearers after refitting with daily disposable CLs and to identify potential biomarkers of success in CL discomfort (CLD) management. METHODS: Symptomatic CL wearers (CLDEQ-8 ≥ 12) were refitted (V1) with daily disposable CLs (Delefilcon A). After one month (V2), participants were classified into the post-fitting non-symptomatic (CLDEQ <12) and symptomatic (CLDEQ ≥12) groups. At each visit, the participants were clinically evaluated, tears were collected, and 20 inflammatory mediators and substance P (SP) were measured using multiplex immunobead analysis and ELISA, respectively. The detection rates and concentrations were compared between visits and groups, and logistic regression models were performed. RESULTS: Forty-three subjects (32 women/11 men; mean age: 23.2 ± 4.9 years) were enrolled. The IL-1ß and IL-9 detection rates were higher at V2 (p ≤ 0.044). The detection rates of IL-1ß, IL-9, MIP-1α/CCL3, and MMP-9 at V1 (p ≤ 0.045) and IL-17A at V2 (p ≤ 0.014) were higher in the post-fitting symptomatic group. The tear IL-9 concentration was increased at V2 (p = 0.018). The tear concentrations of fractalkine/CX3CL1, IL-2, IL-6, IL-10, MCP-3/CCL7, MIP-1ß, NGF, RANTES/CCL5, and TNF-α were higher in the post-fitting symptomatic group (p ≤ 0.044). Additionally, levels of fractalkine/CX3CL1, IL-2, IL-6, IL-10, RANTES/CCL5, and TNF-α at V1 were significantly associated with the post-fitting grouping (p ≤ 0.044). CONCLUSIONS: Low tear concentrations of specific inflammatory mediators may be used as a predictive biomarker of success for refitting symptomatic CL wearers with daily disposable CLs. However, complementary treatments might be required for symptomatic CL wearers with higher levels of these inflammatory molecules.

6.
Ophthalmol Ther ; 13(5): 1197-1210, 2024 May.
Article in English | MEDLINE | ID: mdl-38446281

ABSTRACT

INTRODUCTION: To evaluate the short-term efficacy of cyclosporine A (CsA)-0.1% cationic emulsion (CE) in patients with dry eye disease (DED) and mitigation of the inflammatory flares triggered by desiccating stress environments. METHODS: A single-center non-randomized clinical trial was performed at a tertiary care setting. Twenty patients with DED treated with CsA 0.1% CE were exposed to a normal controlled environment (NCE) (23 °C, 50% relative humidity) and an adverse controlled environment (ACE) (23 °C, 10% relative humidity, 0.43 m/s localized airflow) during baseline and the 1- and 3-month visits. Patients underwent the following evaluations: conjunctival hyperemia and staining, corneal fluorescein staining (CFS) using the Oxford and Cornea and Contact Lens Research Unit (CCLRU) scale, meibomian gland (MG) secretion quality, Dry Eye Questionnaire-5, Symptom Assessment in Dry Eye (SANDE II), and Change in Dry Eye Symptoms Questionnaire. Multivariate models were adjusted for statistical analysis. RESULTS: Nineteen women and one man (mean age, 58.9 ± 12.3 years) completed the study. All symptom questionnaires, CFS, conjunctival hyperemia and staining, and MG secretion quality improved (p ≤ 0.003) with 1 month of treatment; improvements were maintained after 3 months (p ≤ 0.02), except for SANDE II (p ≥ 0.07). The CFS worsening (total CCLRU) after baseline ACE exposure (from 8.6 to 10.1) was higher, although not significant (p = 0.64), compared with 1 month (from 5.4 to 5.8) and 3 months (from 5.0 to 5.9) after treatment. CONCLUSION: Topical CsA-0.1% CE improved DED signs and symptoms after 1 month of treatment under controlled environmental conditions. Future studies should confirm the benefit of CsA-0.1% CE in desiccating stress environments. TRIAL REGISTRATION: ClinicalTrials.gov identifier, NCT04492878.

7.
Cont Lens Anterior Eye ; 45(6): 101705, 2022 12.
Article in English | MEDLINE | ID: mdl-35562228

ABSTRACT

PURPOSE: To investigate the effect of time of day on tear evaporation rate (TER) and tear break-up time, and its possible relationship with the concentration of inflammatory tear molecules (cytokines) in healthy subjects. METHODS: Participants with healthy ocular surfaces attended 3 visits, including the screening visit (V0), the 2nd visit (V1) and the 3rd visit (V2). There were 7-day intervals between visits. Participants with Dry Eye Disease (DED) were excluded by using appropriate clinical tests during V0. Clinical evaluation (TER and Non-Invasive Tear Break-Up Time (NITBUT)) and tear collection were performed during V1 and V2, between 9 and 10AM and 3-4PM. The relative humidity and temperature of the examination room were also measured. The tear fluid concentrations of 15 cytokines were measured by multiplex bead analysis. RESULTS: Seven men and 10 women (mean age ± S.D; 25.1 ± 6.63 years old) participated in the study. There were no differences in neither the TER and NITBUT outcomes, nor humidity and temperature among times or visits. Eleven out of the 15 cytokines measured were detectable in tear fluids in > 50% of the participants. In the tear levels, no significant (p > 0.05) inter- and/or intra-day differences were detected for EGF, fractalkine, IL-1RA, IL-1ß and IP-10. However, significant inter-day differences were found in the tear levels of IL-10 (p = 0.027), IFN-γ (p = 0.035) and TNF-α(p = 0.04) and intra-day differences in the tear levels of IL-8/CXCL8 (p = 0.034) and MCP-1 (p = 0.002). A significant correlation between TER and IL1-ß, IL-2, and Fractalkine (p = 0.03, p = 0.03 and p = 0.046, respectively) was found at V1. CONCLUSIONS: NITBUT and TER values had no significant variability over the course of a day (AM versus PM), or on different days in healthy participants when humidity and temperature were constant. However, some tear molecule levels did show inter- and intra-day variability, having an inconsistent and moderate correlation with TER diurnal variation.


Subject(s)
Cytokines , Dry Eye Syndromes , Male , Female , Humans , Adolescent , Young Adult , Adult , Chemokine CX3CL1 , Tears , Dry Eye Syndromes/diagnosis , Humidity
8.
Ophthalmol Ther ; 9(4): 797-807, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32968960

ABSTRACT

The most prevalent type of meibomian gland dysfunction (MGD), which is obstructive, is the main cause of evaporative dry eye and is characterized by changes in the meibum composition and duct obstruction. Eyelid hygiene has usually been the most common clinical approach. However, alternative therapies for MGD are emerging on the market. Some warming and humidity devices have led to an improvement in the signs and symptoms in MGD patients. Likewise, eyelid massaging and cleaning devices are also beneficial for ocular signs and symptoms; however, patients usually need more than one session to maintain the therapeutic effect. Thermal pulsation has been reported to be more efficient than other strategies, and the effects can last up to 12 months. Moreover, intense pulsed light therapy has been demonstrated to improve ocular signs and symptoms alone and in combination with other therapies. Proper counseling of clinicians considering MGD status and patient compliance will help patients to undergo the adequate technique that best suits their condition.

SELECTION OF CITATIONS
SEARCH DETAIL