Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 104
Filter
Add more filters

Publication year range
1.
N Engl J Med ; 390(1): 9-19, 2024 Jan 04.
Article in English | MEDLINE | ID: mdl-37888915

ABSTRACT

BACKGROUND: Among patients with chronic limb-threatening ischemia (CLTI) and infrapopliteal artery disease, angioplasty has been associated with frequent reintervention and adverse limb outcomes from restenosis. The effect of the use of drug-eluting resorbable scaffolds on these outcomes remains unknown. METHODS: In this multicenter, randomized, controlled trial, 261 patients with CLTI and infrapopliteal artery disease were randomly assigned in a 2:1 ratio to receive treatment with an everolimus-eluting resorbable scaffold or angioplasty. The primary efficacy end point was freedom from the following events at 1 year: amputation above the ankle of the target limb, occlusion of the target vessel, clinically driven revascularization of the target lesion, and binary restenosis of the target lesion. The primary safety end point was freedom from major adverse limb events at 6 months and from perioperative death. RESULTS: The primary efficacy end point was observed (i.e., no events occurred) in 135 of 173 patients in the scaffold group and 48 of 88 patients in the angioplasty group (Kaplan-Meier estimate, 74% vs. 44%; absolute difference, 30 percentage points; 95% confidence interval [CI], 15 to 46; one-sided P<0.001 for superiority). The primary safety end point was observed in 165 of 170 patients in the scaffold group and 90 of 90 patients in the angioplasty group (absolute difference, -3 percentage points; 95% CI, -6 to 0; one-sided P<0.001 for noninferiority). Serious adverse events related to the index procedure occurred in 2% of the patients in the scaffold group and 3% of those in the angioplasty group. CONCLUSIONS: Among patients with CLTI due to infrapopliteal artery disease, the use of an everolimus-eluting resorbable scaffold was superior to angioplasty with respect to the primary efficacy end point. (Funded by Abbott; LIFE-BTK ClinicalTrials.gov number, NCT04227899.).


Subject(s)
Angioplasty , Blood Vessel Prosthesis Implantation , Chronic Limb-Threatening Ischemia , Drug-Eluting Stents , Peripheral Arterial Disease , Popliteal Artery , Humans , Absorbable Implants , Angioplasty/adverse effects , Angioplasty/methods , Angioplasty, Balloon/adverse effects , Angioplasty, Balloon/methods , Blood Vessel Prosthesis Implantation/methods , Chronic Disease , Chronic Limb-Threatening Ischemia/etiology , Chronic Limb-Threatening Ischemia/surgery , Everolimus/administration & dosage , Everolimus/adverse effects , Everolimus/therapeutic use , Immunosuppressive Agents/administration & dosage , Immunosuppressive Agents/adverse effects , Immunosuppressive Agents/therapeutic use , Ischemia/drug therapy , Ischemia/etiology , Ischemia/surgery , Peripheral Arterial Disease/complications , Peripheral Arterial Disease/drug therapy , Peripheral Arterial Disease/surgery , Popliteal Artery/surgery , Tissue Scaffolds , Treatment Outcome
2.
J Endovasc Ther ; : 15266028241234001, 2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38410837

ABSTRACT

PURPOSE: To compare procedural and long-term costs associated with the use of Balloon-Expandable Covered Stents (BECS) in the management of Aortoiliac Occlusive Disease (AIOD). MATERIALS AND METHODS: A cost-consequence model was developed to simulate the intra- and post-operative management of patients with AIOD from the perspective of private health-payers. The study assessed the costs of the LifeStream (BD, Franklin Lakes, New Jersey), iCAST/Advanta V12 (Getinge, Goteborg, Sweden), BeGraft Peripheral (Bentley, Hechingen, Germany), and Viabahn Balloon Expandable (VBX) (W.L. Gore, Flagstaff, Arizona) BECS devices. Device costs were identified from the Australian Prosthesis List, whereas clinical outcomes of BECS were estimated from a systematic review of the literature. Costs were calculated over 24 and 36 month time horizons and reported in US dollars. RESULTS: Long-term, per-patient cost of each device at 24 and 36 months was $6253/$6634 for the LifeStream; $6359/$6869 for the iCAST/Advanta V12; $4806 (data available to 24 months) for the BeGraft Peripheral; and $4839/$5046 for the Viabahn VBX, respectively. Most of the cost difference was attributed to the number of stents required per treated limb and frequency of clinically-driven target lesion revascularization events. CONCLUSIONS: Best-available clinical evidence and economic modeling demonstrates that the BeGraft Peripheral and Viabahn VBX were of similar cost and the least costly options at 24 months, whereas at 36 months, the lowest cost BECS option for the treatment of AIOD was the Viabahn VBX. CLINICAL IMPACT: This analysis supports economically informed decision-making for health-payers managing systems that care for patients with AIOD. Stent length and avoiding reintervention were identified as key areas of cost-saving for future BECS development.

3.
Arterioscler Thromb Vasc Biol ; 43(6): 836-851, 2023 06.
Article in English | MEDLINE | ID: mdl-37128915

ABSTRACT

Peripheral artery disease (PAD) is a vascular disorder caused by occlusive atherosclerosis, which commonly impairs blood flow to the lower extremities. The prevalence of PAD is increasing globally with >200 million people affected. PAD remains a growing global health problem as the population continues to age and diabetes incidence grows. Many patients with PAD, most notably those with critical limb ischemia, fail attempts at surgical and percutaneous intervention to improve blood flow and are at risk of amputation. Gene therapy provides an opportunity to change the clinical course of PAD in these patients via strategies that increase vascular supply through angiogenesis and arteriogenesis improving muscle perfusion and function in ischemic legs. This article discusses gene therapy approaches in the context of PAD, both intermittent claudication and critical limb ischemia, and the promise of adeno-associated virus-based strategies delivering not just VEGFs (vascular endothelial growth factors) but a range of other mediators as potential new therapeutics. We also highlight challenges and failures in the clinical translation of gene therapy for PAD and how at least some of these obstacles may be overcome using adeno-associated virus.


Subject(s)
Dependovirus , Peripheral Arterial Disease , Humans , Dependovirus/genetics , Chronic Limb-Threatening Ischemia , Peripheral Arterial Disease/genetics , Peripheral Arterial Disease/therapy , Peripheral Arterial Disease/metabolism , Intermittent Claudication/therapy , Lower Extremity , Ischemia/genetics , Ischemia/therapy , Ischemia/metabolism
4.
Cochrane Database Syst Rev ; 5: CD013421, 2024 05 02.
Article in English | MEDLINE | ID: mdl-38695613

ABSTRACT

BACKGROUND: During vascular interventions, connections that link arteries, veins, or synthetic grafts, which are known as an 'anastomosis', may be necessary. Vascular anastomoses can bleed from the needle holes that result from the creation of the anastomoses. Various surgical options are available for achieving hemostasis, or the stopping of bleeding, including the application of sealants directly onto the bleeding vessels or tissues. Sealants are designed for use in vascular surgery as adjuncts when conventional interventions are ineffective and are applied directly by the surgeon to seal bleeding anastomoses. Despite the availability of several different types of sealants, the evidence for the clinical efficacy of these hemostatic adjuncts has not been definitively established in vascular surgery patients. OBJECTIVES: To evaluate the benefits and harms of sealants as adjuncts for achieving anastomotic site hemostasis in patients undergoing vascular surgery. SEARCH METHODS: The Cochrane Vascular Information Specialist conducted systematic searches of the following databases: the Cochrane Vascular Specialised Register via the Cochrane Register of Studies; the Cochrane Central Register of Controlled Trials (CENTRAL); MEDLINE via Ovid; Embase via Ovid ; and CINAHL via EBSCO. We also searched ClinicalTrials.gov and the WHO International Clinical Trials Registry Platform for clinical trials. Reference lists of included trials and relevant reviews were also searched. The latest search date was 6 March 2023. SELECTION CRITERIA: We included randomized controlled trials that compared fibrin or synthetic sealant use with alternative interventions (e.g. manual compression, reversal of anticoagulation) for achieving anastomotic-site hemostasis in vascular surgery procedures. We included participants who underwent the creation of an anastomosis during vascular surgery. We excluded non-vascular surgery patients. DATA COLLECTION AND ANALYSIS: We have used standard Cochrane methods. Our primary outcomes were time to hemostasis, failure of hemostatic intervention, and intraoperative blood loss. Our secondary outcomes were operating time, death from bleeding complications up to 30 days, postoperative bleeding up to 30 days, unplanned return to the operating room for bleeding complications management up to 30 days, quality of life, and adverse events. We used GRADE to assess the certainty of evidence for each outcome. MAIN RESULTS: We found 24 randomized controlled trials that included a total of 2376 participants who met the inclusion criteria. All trials compared sealant use with standard care controls, including oxidized cellulose, gelatin sponge, and manual compression. All trials were at high risk of performance bias, detection bias, and other sources of bias. We downgraded the certainty of evidence for risk of bias concerns, inconsistency, imprecision and possible publication bias. Combining data on time to hemostasis showed that sealant use may reduce the mean time to hemostasis compared to control (mean difference (MD) -230.09 seconds, 95% confidence interval (CI) -329.24 to -130.94; P < 0.00001; 7 studies, 498 participants; low-certainty evidence). Combining data on failure of hemostatic intervention showed that sealant use may reduce the rate of failure compared to control, but the evidence is very uncertain (risk ratio (RR) 0.46, 95% CI 0.35 to 0.61; P < 0.00001; 17 studies, 2120 participants; very low-certainty evidence). We did not detect any clear differences between the sealant and control groups for intraoperative blood loss (MD -32.69 mL, 95% CI -96.21 to 30.83; P = 0.31; 3 studies, 266 participants; low-certainty evidence); operating time (MD -18.72 minutes, 95% CI -40.18 to 2.73; P = 0.09; 4 studies, 436 participants; low-certainty evidence); postoperative bleeding (RR 0.78, 95% CI 0.59 to 1.04; P = 0.09; 9 studies, 1216 participants; low-certainty evidence), or unplanned return to the operating room (RR 0.27, 95% CI 0.04 to 1.69; P = 0.16; 8 studies, 721 participants; low-certainty evidence). No studies reported death from bleeding or quality of life outcomes. AUTHORS' CONCLUSIONS: Based on meta-analysis of 24 trials with 2376 participants, our review demonstrated that sealant use for achieving anastomotic hemostasis in vascular surgery patients may result in reduced time to hemostasis, and may reduce rates of hemostatic intervention failure, although the evidence is very uncertain, when compared to standard controls. Our analysis showed there may be no differences in intraoperative blood loss, operating time, postoperative bleeding up to 30 days, and unplanned return to the operating room for bleeding complications up to 30 days. Deaths and quality of life could not be analyzed. Limitations include the risk of bias in all studies. Our review has demonstrated that using sealants may reduce the time required to achieve hemostasis and the rate of hemostatic failure. However, a significant risk of bias was identified in the included studies, and future trials are needed to provide unbiased data and address other considerations such as cost-effectiveness and adverse events with sealant use.


Subject(s)
Anastomosis, Surgical , Hemostasis, Surgical , Randomized Controlled Trials as Topic , Vascular Surgical Procedures , Humans , Hemostasis, Surgical/methods , Hemostatics/therapeutic use , Fibrin Tissue Adhesive/therapeutic use , Blood Loss, Surgical/prevention & control , Tissue Adhesives/therapeutic use
5.
Ann Surg ; 277(4): e955-e962, 2023 04 01.
Article in English | MEDLINE | ID: mdl-35129507

ABSTRACT

OBJECTIVE: Compare long-term mortality, secondary intervention and secondary rupture following elective endovascular aneurysm repair (EVAR) and open surgical repair (OSR). BACKGROUND: EVAR has surpassed OSR as the most common procedure used to repair abdominal aortic aneurysm (AAA), but evidence regarding long-term outcomes is inconclusive. METHODS: We included patients in linked clinical registry and administrative data undergoing EVAR or OSR for intact AAA between January 2010 and June 2019. We used an inverse probability of treatment-weighted survival analysis to compare all-cause mortality, cause-specific mortality, secondary interventions and secondary rupture, and evaluate the impact of secondary interventions and secondary rupture on all-cause mortality. RESULTS: The study included 3460 EVAR and 427 OSR patients. Compared to OSR, the EVAR all-cause mortality rate was lower in the first 30 days [adjusted hazard ratio (HR) = 0.22, 95% confidence interval (CI) 0.140.33], but higher between 1 and 4 years (HR = 1.29, 95% CI 1.12-1.48) and after 4years (HR = 1.41, 95% CI 1.23-1.63). Secondary intervention rates were higher over the first 30 days (HR = 2.26, 95% CI 1.11-4.59), but lower between 1 and 4years (HR = 0.59, 95% CI 0.48-0.74). Secondary aortic intervention rates were higher across the entire follow-up period (HR = 2.52, 95% CI 2.06-3.07). Secondary rupture rates did not differ significantly (HR = 1.06, 95% CI 0.73-1.55). All-cause mortality beyond 1 year remained significantly higher for EVAR after adjusting for any secondary interventions, or secendary rupture. CONCLUSIONS: EVAR has an early survival benefit compared to OSR. However, elevated long-term mortality and higher rates of secondary aortic interventions and subsequent aneurysm repair suggest that EVAR may be a less durable method of aortic aneurysm exclusion.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aortic Aneurysm, Abdominal/surgery , Routinely Collected Health Data , Endovascular Procedures/methods , Registries , Treatment Outcome , Risk Factors , Retrospective Studies , Postoperative Complications
6.
Ann Surg ; 278(3): e626-e633, 2023 09 01.
Article in English | MEDLINE | ID: mdl-36538620

ABSTRACT

OBJECTIVE: To examine long-term outcomes after endovascular (EVAR) and open repairs (OAR) for intact abdominal aortic aneurysms in Australia, Germany, and the United States, using a unified study design. BACKGROUND: Similarities and differences in long-term outcomes after EVAR versus OAR across countries remained unclear, given differences in designs across existing studies. METHODS: We identified patients aged >65 years undergoing intact abdominal aortic aneurysm repairs during 2010-2017/2018. We compared long-term patient mortality and reintervention after EVAR and OAR using Kaplan-Meier analyses and Cox regressions. Propensity score matching was performed within each country to adjust for differences in baseline patient characteristics between procedure groups. RESULTS: We included 3311, 4909, and 145363 patients from Australia, Germany, and the United States, respectively. The median patient age was 76 to 77 years, and most patients were males (77%-84%). Patient mortality was lower after EVAR than OAR within the first 60 days and became similar at 3-year follow-up (Australia 14.7% vs 16.5%, Germany 18.2% vs 19.7%, United States: 24.4% vs 24.4%). At the end of follow-up, patient mortality after EVAR was higher than OAR in Australia [ hazard ratio (HR) 95% CI: 1.21 (0.96-1.54)] but similar to OAR in Germany [HR 95% CI: 0.92 (0.80-1.07)] and the United States [HR 95% CI: 1.02 (0.99-1.05)]. The risk of reintervention after EVAR was more than twice that after OAR in Australia [HR 95% CI: 2.60 (1.09-6.15)], Germany [HR 95% CI: 4.79 (2.56-8.98)], and the United States [HR 95% CI: 2.67 (2.38-3.00)]. The difference in reintervention risk appeared early in German and United States patients. CONCLUSIONS: This multinational study demonstrated important similarities in long-term outcomes after EVAR versus OAR across 3 countries. Variation in long-term mortality and reintervention comparisons indicates possible differences in patient profiles, surveillance, and best medical therapy across countries.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Male , Humans , United States/epidemiology , Female , Risk Factors , Endovascular Procedures/methods , Treatment Outcome , Time Factors , Retrospective Studies , Aortic Aneurysm, Abdominal/surgery , Germany/epidemiology , Blood Vessel Prosthesis Implantation/adverse effects
7.
J Endovasc Ther ; 30(2): 176-184, 2023 04.
Article in English | MEDLINE | ID: mdl-35098757

ABSTRACT

INTRODUCTION: Juxta-anastomotic stenosis (JXAS) is a common problem afflicting the arteriovenous fistula (AVF). This study aimed to evaluate the safety and long-term efficacy of an interwoven nitinol stent (Supera, Abbott Vascular, Santa Clara, CA, USA) in the treatment of radiocephalic AVF JXAS. METHODS: A single-center, retrospective, observational study was conducted of patients with failing AVF due to JXAS treated with an interwoven nitinol stent. End points included JXAS target lesion primary patency, access circuit primary patency, assisted access circuit primary patency, and endovascular intervention rate (EIR). RESULTS: Sixty patients were treated with a Supera stent in the JXAS between February 2014 and March 2020. One patient was excluded (AVF used for illicit drug use), leaving 59 patients (67.8% male, mean age 66.9 ± 11.4 years [range: 40-84]) with typical medical comorbidities. Overall, 45.8% of patients had previous AVF intervention. The stent was inserted with a 100% technical success rate with a mean follow-up of 729.6 ± 456.0 days (range: 5-2182 days). Juxta-anastomotic stenosis target lesion primary patency was 68.2 ± 6.6%, 53.3 ± 7.5%, and 46.2 ± 8.1% at 12, 24, and 36 months, respectively. The EIR was .64 (0-3.29) procedures/patient/year, after which the assisted access circuit primary patency rate was 94.3 ± 3.2% at 12, 24, and 36 month time points. Three thrombosed circuits occurred which were all successfully salvaged with no difference in patency by indication for procedure and no AVFs lost/abandoned out to 3 years. Avoidance of stent post-dilatation and the presence of stent mal-apposition were associated with improved primary patency, and reduced EIR, which may suggest an importance in vessel preparation prior to stent implantation. CONCLUSION: Interwoven nitinol stent treatment of the failing AVF with JXAS results in promising 3 year JXAS patency, with a low rate of endovascular re-intervention for those circuits developing restenosis. All AVFs were maintained over 3 years, demonstrating this treatment allows for long-term radiocephalic AVF vascular access.


Subject(s)
Angioplasty, Balloon , Arteriovenous Fistula , Arteriovenous Shunt, Surgical , Humans , Male , Middle Aged , Aged , Female , Arteriovenous Shunt, Surgical/adverse effects , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/therapy , Vascular Patency , Retrospective Studies , Constriction, Pathologic , Renal Dialysis , Angioplasty, Balloon/adverse effects , Treatment Outcome , Stents , Arteriovenous Fistula/etiology
8.
Eur J Vasc Endovasc Surg ; 65(2): 272-280, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36334901

ABSTRACT

OBJECTIVE: To compare rates of mortality, rupture, and secondary intervention following endovascular repair (EVAR) of intact abdominal aortic aneurysms (AAA) using contemporary endograft devices from three major manufacturers. METHODS: This was a retrospective cohort study using linked clinical registry (Australasian Vascular Audit) and all payer administrative data. Patients undergoing EVAR for intact AAA between 2010 and 2019 in New South Wales, Australia were identified. Rates of all cause death, secondary rupture, and secondary intervention (subsequent aneurysm repair; other secondary aortic intervention) were compared for patients treated with Cook, Medtronic, and Gore standard devices. Inverse probability of treatment weighted proportional hazards and competing risk regression were used to adjust for patient, clinical, and aneurysm characteristics, using Cook as the referent device. RESULTS: This study identified 2 874 eligible EVAR patients, with a median follow up of 4.1 (maximum 9.5) years. Mortality rates were similar for patients receiving different devices (ranging between 7.0 and 7.3 per 100 person years). There was no statistically significant difference between devices in secondary rupture rates, which ranged between 0.4 and 0.5 per 100 person years. Patients receiving Medtronic and Gore devices tended to have higher crude rates of subsequent aneurysm repair (1.5 per 100 person years) than patients receiving Cook devices (0.8 per 100 person years). This finding remained in the adjusted analysis, but was only statistically significant for Medtronic devices (HR 1.57, 95% CI 1.02 - 2.47; HR 1.73, 95% CI 0.94 - 3.18, respectively). CONCLUSION: Major endograft devices have similar overall long term safety profiles. However, there may be differences in rates of secondary intervention for some devices. This may reflect endograft durability, or patient selection for different devices based on aneurysm anatomy. Continuous comparative assessments are needed to guide evidence for treatment decisions across the range of available devices.

9.
Vasa ; 52(3): 147-159, 2023 May.
Article in English | MEDLINE | ID: mdl-36924047

ABSTRACT

Together with colleagues from different disciplines, including cardiologists, interventional radiologists and vascular surgeons, committee members of the of the German Society of Angiology (Deutsche Gesellschaft für Angiologie [DGA]), developed a novel algorithm for the endovascular treatment of peripheral chronic total occlusive lesions (CTOs). Our aim is to improve patient and limb related outcomes, by increasing the success rate of endovascular procedures. This can be achieved by adherence to the proposed crossing algorithm, aiding the standardization of endovascular procedures. The following steps are proposed: (i) APPLY Duplex sonography and if required 3D techniques such as computed tomography or magnetic resonance angiography. This will help you to select the optimal access site. (ii) EVALUATE the CTO cap morphology and distal vessel refilling sites during diagnostic angiography, which are potential targets for a retrograde access. (iii) START with antegrade wiring strategies including guidewire (GW) and support catheter technology. Use GW escalation strategies to penetrate the proximal cap of the CTO, which may usually be fibrotic and calcified. (iv) STOP the antegrade attempt depending on patient specific parameters and the presence of retrograde options, as evaluated by pre-procedural imaging and during angiography. (v) In case of FAILURE, consider advanced bidirectional techniques and reentry devices. (vi) In case of SUCCESS, externalize the GW and treat the CTO. Manage the retrograde access at the end of the endovascular procedure. (vii) STOP the procedure if no progress can be obtained within 3 hours, in case of specific complications or when reaching maximum contrast administration based on individual patient's renal function. Consider radiation exposure both for patients and operators. In this manuscript we systematically follow and explain each of the steps (i)-(vi) based on practical examples from our daily routine. We strongly believe that the integration of this algorithm in the daily practice of endovascular specialists, can improve vessel and patient specific outcomes.


Subject(s)
Endovascular Procedures , Peripheral Arterial Disease , Humans , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Endovascular Procedures/adverse effects , Angiography , Catheterization , Treatment Outcome , Chronic Disease
11.
J Vasc Surg ; 75(2): 641-650.e2, 2022 02.
Article in English | MEDLINE | ID: mdl-34506894

ABSTRACT

BACKGROUND: The clinical utility of the native arteriovenous fistula (AVF) has been limited by the prolonged time required for maturation, the low overall maturation rate, and subsequent abandonment. Endovascular intervention has been increasingly accepted as the first-line therapy for AVF stenosis. The objective of the present study was to evaluate the AVF formation outcomes when early endovascular intervention was selectively performed to bring about timely AVF maturation. METHODS: We performed a retrospective study (February 2014 to February 2020) of 82 AVF consecutive patients (mean age, 62.5 ± 13.5 years; range, 17-83; 58 men [70.7%]) with end-stage renal failure who had undergone vascular access construction at a single institution. The 4-year AVF patency, vascular diameters, hemodialysis parameters, reintervention rate, and mortality were analyzed. RESULTS: Radiocephalic AVF was the most common fistula constructed (71 patients; 88.6%). The evaluation at a mean of 46.2 ± 56.0 days (range, 5-343 days) after AVF formation revealed 33 immature AVFs (40.2%). Subsequently, 19 patients had undergone endovascular procedures, including angioplasty and/or stenting of the juxta-anastomosis, cannulation zones, and/or outflow segments to bring about timely maturation of the AVF. Hence, 93.9% of the AVFs had reached functional patency (maturation) by 6 months after formation, with a mean time to maturation of 67.8 ± 65.9 days (range, 5-320 days). After reaching maturation, the primary access functional patency was 82% ± 4.3% at 6 months, 58% ± 5.5% at 12 months, and 34% ± 6.8% at 48 months. The primary assisted access functional patency was 95% ± 2.4% at 6 months, 90% ± 3.3% at 12 months, and 83% ± 4.7% at 48 months. A total of 121 endovascular interventions were performed to maintain patency, equating to an endovascular reintervention rate of 0.37 procedure/patient year. The mean arterial, venous, and brachial flow rates did not change significantly after maturation with a mean AVF (primary assisted functional patency) survival time of 5.9 ± 0.26 years (range, 5.33-6.36 years) from maturation. Only 12 thromboses had occurred after the first follow-up review after AVF formation. These were all salvaged using endovascular techniques, leading to 100% total secondary functional patency at 4 years. The 5-year estimated all-cause mortality was 45.6% ± 12.7%. CONCLUSIONS: The AVF maturation rate and interval to maturation were improved when early endovascular intervention was selectively performed after AVF formation. This allowed for near universal maturation. In addition, once matured, the use of ongoing endovascular reinterventions allowed for a low reintervention rate and long-term patency, providing reliable long-term renal vascular access.


Subject(s)
Arteriovenous Fistula/etiology , Arteriovenous Shunt, Surgical/adverse effects , Brachial Artery , Endovascular Procedures/methods , Kidney Failure, Chronic/therapy , Renal Dialysis/methods , Stents , Adolescent , Adult , Aged , Aged, 80 and over , Arteriovenous Fistula/surgery , Female , Follow-Up Studies , Humans , Male , Middle Aged , Renal Dialysis/adverse effects , Retrospective Studies , Risk Factors , Time Factors , Young Adult
12.
Vasc Med ; 27(1): 63-72, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34392750

ABSTRACT

INTRODUCTION: Venous leg ulcers (VLU) embody the most severe stage of the broad spectrum of chronic venous disease. Approximately 40% of patients with VLU present with the underlying deep venous disease (DVD). Although the data are scarce, these deep venous disease-related VLU (DRV) are thought to have higher recurrence rates and a substantial economic burden. The objective of this study was to assess the economic burden of DRV across Australia, France, Germany, Italy, Spain, the UK, and the USA. METHODS: A comprehensive literature review was undertaken to identify publications documenting the incidence and prevalence of VLU and DRV, medical resource utilization, and associated costs of DRV. Findings from this literature review were used to estimate the economic burden of illness, including direct medical costs over a 12-month interval following initial presentation of a newly formed DRV. RESULTS: Total annual incidence of new or recurrent DRV in Australia, France, Germany, Italy, Spain, UK, and the US are estimated at 122,000, 263,000, 345,000, 253,000, 85,000, 230,000, and 643,000 events, respectively, in 2019. Incidence ranges from 0.73 to 3.12 per 1000 persons per year. The estimated annual direct medical costs for patients managed conservatively in these geographies total ~ $10.73 billion (USD) or $5527 per person per year. CONCLUSION: The availability of published data on the costs of VLU care varies widely across countries considered in this analysis. Although country-specific VLU practice patterns vary, there is a uniform pattern of high-cost care.


Subject(s)
Financial Stress , Varicose Ulcer , France , Humans , Incidence , Prevalence , Varicose Ulcer/diagnosis , Varicose Ulcer/epidemiology , Varicose Ulcer/therapy
13.
J Vasc Surg ; 73(1): 311-322, 2021 01.
Article in English | MEDLINE | ID: mdl-32890719

ABSTRACT

BACKGROUND: Peripheral vascular devices (stents and balloons) coated with paclitaxel were developed to address suboptimal outcomes associated with percutaneous revascularization procedures of the femoral-popliteal arteries. In randomized controlled trials (RCT), paclitaxel-coated devices (PCD) provided increased long-term patency and a decreased need for repeat revascularization procedures compared with uncoated devices. This finding resulted in the adoption of their use for endovascular lower extremity revascularization procedures. However, in late 2018 a study-level meta-analysis showed increased all-cause mortality at 2 years or more after the procedure in patients treated with PCDs. This review examines the subsequent data evaluation following the publication of the meta-analysis. METHODS: We review the published responses of physicians, regulatory agencies, and patient advocates during 15-month period after the meta-analysis. We present the additional data gathered from RCTs that comprised the meta-analysis and safety outcomes from large insurance databases in both the United States and Europe. RESULTS: Immediately after the publication of the meta-analysis, concern for patient safety resulted in less PCD use, the suspension of large RCTs evaluating their use, and the publication of a letter from the U.S. Food and Drug Administration informing physicians that there was uncertainty in the benefit-risk profile of these devices for indicated patients and that the potential risk should be assessed before the use of PCDs. Review of the meta-analysis found that a mortality signal was present, but criticisms included that the evaluation was performed on study-level, not patient-level data, and the studies in the analysis were heterogenous in device type, paclitaxel doses, and patient characteristics. Further, the studies were not designed to be pooled nor were they powered for evaluating long-term safety. Clinical characteristics associated with a drug effect or causal relationship were also absent. Specifically, there was no dose response, no clustering of causes of death, and a lack of signal consistency across geographic regions. As more long-term data became available in the RCTs the strength of the mortality signal diminished and analysis of real-world use in large insurance databases, showed that there was no significant increase in all-cause mortality associated with PCD use. CONCLUSIONS: The available data do not provide definitive proof for increased mortality with PCD use. A key observation is that trial design improvements will be necessary to better evaluate the risk-benefit profile of PCDs.


Subject(s)
Angioplasty, Balloon/methods , Arterial Occlusive Diseases/therapy , Femoral Artery , Paclitaxel/administration & dosage , Popliteal Artery , Arterial Occlusive Diseases/mortality , Coated Materials, Biocompatible , Dose-Response Relationship, Drug , Follow-Up Studies , Global Health , Humans , Survival Rate/trends , Time Factors , Tubulin Modulators/administration & dosage
14.
Catheter Cardiovasc Interv ; 97(1): 142-149, 2021 01 01.
Article in English | MEDLINE | ID: mdl-33037869

ABSTRACT

OBJECTIVES: The aim of this study was to perform a long-term evaluation of an everolimus eluting, bioresorbable vascular scaffold (BVS) in the treatment of de novo atherosclerotic disease within crural arteries. METHODS: A prospective, single-arm study was performed enrolling patients with chronic lower limb ischemia between 2013 and 2018. RESULTS: Fifty-five limbs in 48 patients (56% male; mean age 82.1 ± 8.0 years, range 65-97) were treated for critical limb ischemia (72.7%) or severe claudication (27.3%). Seventy-one scaffolds were used to treat 61 lesions with a mean length of 20.1 ± 10.8 mm. During a mean follow-up period of 35.2 ± 20.4 months, 22 (45.8%) patients had died. No late or very-late scaffold thrombosis was observed. Overall, clinical improvement was observed in 90.9% and a limb-salvage rate of 100% was observed. Binary restenosis was detected in 11/71(15.5%) scaffolds. Primary patency and freedom from clinically driven target lesion revascularization rates at 12, 24, 36, 48, and 60 months were 90.8% (95% confidence interval 80.7-95.8), 90.8% (80.7-95.8), 79.7% (65.8-88.4), 76.3% (61.1-86.2), 72.3% (55.5-83.4) and 97.2% (89.2-99.3), 97.2% (89.2-99.3), 90.7% (78.7-96.1), 90.7% (78.7-96.1), and 90.7% (78.7-96.1), respectively. CONCLUSIONS: This long-term study shows excellent rates of patency and freedom from target lesion revascularization using the absorb BVS below-the-knee. This proof of concept study lays the foundation for the next generation of BVS to be evaluated in infrapopliteal arteries.


Subject(s)
Absorbable Implants , Everolimus , Aged , Aged, 80 and over , Everolimus/adverse effects , Female , Humans , Male , Popliteal Artery/diagnostic imaging , Prospective Studies , Prosthesis Design , Tissue Scaffolds , Treatment Outcome , Vascular Patency
15.
J Endovasc Ther ; 28(5): 755-777, 2021 10.
Article in English | MEDLINE | ID: mdl-34106028

ABSTRACT

PURPOSE: A late increased mortality risk has been reported in a summary level meta-analysis of patients with femoropopliteal artery occlusive disease treated with paclitaxel-coated angioplasty balloons and stents. However, at the longer follow up timepoints that analysis was limited by small trial numbers and few participants. The aim of this study was to report an updated summary level risk of all-cause mortality after treatment with paclitaxel-coated devices in that same patient group. MATERIALS AND METHODS: We performed a systematic review and meta-analysis of randomized controlled trials to investigate the mortality outcomes associated with paclitaxel-coated devices used to treat patients with occlusive disease of femoropopliteal arteries (last search date December 10, 2020). The single primary endpoint was all-cause mortality. RESULTS: We identified 34 randomized controlled trials (7654 patients; 84% intermittent claudication). There were 622 deaths among 4147 (15.0%) subjects in the paclitaxel device group and 475 deaths among 3507 (13.5%) subjects in the noncoated control group [relative risk ratio (RR) 1.07, 95% confidence interval (CI) 0.96 to 1.20, p=0.20, I2=0%). All-cause mortality was similar between groups at 12 months (34 studies, 7654 patients; RR 0.99, 95% CI 0.81 to 1.22, p=0.94, I2=0%), 24 months (20 studies, 3799 patients; RR 1.16, 95% CI 0.87 to 1.55, p=0.31, I2=0%), and 60 months (9 studies, 2288 patients; RR 1.19, 95% CI 0.98 to 1.45, p=0.08, I2=0%). CONCLUSION: This updated meta-analysis with included additional trials and larger patient numbers shows no evidence of increased risk of all-cause mortality in patients treated with paclitaxel-coated devices, compared with uncoated devices for femoropopliteal disease at all time points to 60 months. There is therefore no justification to limit their use, or alter regulatory body follow-up recommendations in this patient population. SYSTEMATIC REVIEW REGISTRATION: CRD42020216140.


Subject(s)
Paclitaxel , Peripheral Arterial Disease , Coated Materials, Biocompatible , Humans , Paclitaxel/adverse effects , Peripheral Arterial Disease/therapy , Randomized Controlled Trials as Topic , Treatment Outcome
16.
Vasc Med ; 26(2): 195-199, 2021 04.
Article in English | MEDLINE | ID: mdl-33507844

ABSTRACT

Previous studies on everolimus-eluting bioresorbable vascular scaffolds (BVS) have shown promising 1-year primary patency rates in infrapopliteal arteries. Literature from large cohorts on long-term outcomes with the infrapopliteal Absorb BVS (Abbott Vascular) is lacking. The aim of this study is to pool published and unpublished data to provide a more precise estimate of the 24-month outcomes of Absorb BVS for the treatment of infrapopliteal disease. For the pooled analysis, updated original and newly collected data from three cohorts on treatment with the Absorb BVS for de novo infrapopliteal lesions were combined. The primary endpoint was freedom from restenosis. Secondary endpoints were freedom from clinically driven target lesion revascularization (CD-TLR), major amputation and survival. The pooled analysis included a total of 121 patients with 161 lesions, treated with 189 Absorb BVS in 126 limbs. The mean age of the patients was 73 years, 57% had diabetes mellitus, and 75% were classified as Rutherford-Becker class 5 or 6. Of the 161 lesions, 101 (63%) were calcified and 36 (22%) were occlusions. Successful deployment was achieved with all scaffolds. Freedom from restenosis was 91.7% and 86.6% at 12 and 24 months, respectively, and freedom from CD-TLR was 97.2% and 96.6%. Major amputation occurred in 1.6% of the limbs. Overall survival was 85% at 24 months. In conclusion, this pooled analysis represents the largest reported analysis of mid-term results of the Absorb BVS for the management of chronic limb-threatening ischemia. At 24 months, the Absorb BVS was safe with promising clinical outcomes for the treatment of infrapopliteal disease.


Subject(s)
Coronary Artery Disease , Everolimus , Peripheral Arterial Disease , Absorbable Implants , Aged , Everolimus/administration & dosage , Humans , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Popliteal Artery/diagnostic imaging , Prosthesis Design , Treatment Outcome , Vascular Patency
17.
Ann Vasc Surg ; 75: 237-252, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33831519

ABSTRACT

OBJECTIVES: This study aims to assess the use of drug-coated balloon (DCB) in a large patient population under real-world conditions and, specifically, analyse the impact of diabetes mellitus on long term outcomes following DCB utilisation. METHODS: BIOLUX P-III is a prospective, international, multicentre, registry that was conducted at 41 centres. The present study is a 24-month subgroup analysis of patients with diabetes mellitus having infrainguinal lesions treated with the Passeo-18 Lux DCB. The primary endpoints were freedom from major adverse events (MAEs) within 6 months of intervention and freedom from clinically driven target lesion revascularisation (CD-TLR) within 12 months of intervention. RESULTS: Of the 882 patients in the registry, 418 had diabetes (516 lesions). Most diabetics had concomitant hypertension (88.8%) and hyperlipidaemia (70.3%). Insulin dependence was observed in 48.8% of diabetics. Moreover, smoking (62.2%) and chronic renal insufficiency (41.9%) were also found to be common in this cohort. Chronic limb threatening ischemia (Rutherford class ≥4) was present in 53.1% of all patients. 22.9% of lesions were infrapopliteal, while 22.5% of lesions were treated for in-stent restenosis. The mean target lesion length was 85.6 ± 73.2 mm, and 79.4% of lesions were calcified (of which 17.9% were heavily calcified). Overall, device success was 99.7%. Freedom from MAEs was 90.5% (95% confidence interval (95% CI): 87.2-93.0) at 6 months, 85.4% (95% CI: 81.5-88.6) at 12 months and 80% (95% CI: 75.5-83.8) at 24 months. Freedom from CD-TLR was 95.9% (95% CI: 93.8-97.4), 91.6% (95% CI: 88.7-93.8), and 87.1% (95% CI: 83.5-89.9) at 6, 12, and 24 months, respectively. All-cause mortality at 24 months in diabetics was 16.0% (95% CI: 12.6-20.2), and major target limb amputation was 6.1% (95% CI: 4.1-8.9), which was significantly higher than in non-diabetics (8.4% (95% CI: 6.0-11.6), P = 0.0005 and 1.2% (95% CI: 0.5-2.9), P <0.0001, respectively). At 24 months, 82.0% of patients had improved by ≥1 Rutherford class. CONCLUSION: Treatment of a real-world diabetic patient population with the Passeo-18 Lux DCB resulted in high efficacy and low complication rates, despite the fact that diabetic patients usually suffer from a multitude of concomitant comorbidities. CLINICAL TRIAL REGISTRATION: NCT02276313.


Subject(s)
Angioplasty, Balloon/instrumentation , Coated Materials, Biocompatible , Diabetes Mellitus , Lower Extremity/blood supply , Peripheral Arterial Disease/therapy , Vascular Access Devices , Adult , Aged , Aged, 80 and over , Amputation, Surgical , Angioplasty, Balloon/adverse effects , Asia/epidemiology , Australia/epidemiology , Diabetes Mellitus/diagnosis , Diabetes Mellitus/epidemiology , Europe/epidemiology , Female , Humans , Limb Salvage , Male , Middle Aged , Multimorbidity , Peripheral Arterial Disease/diagnosis , Peripheral Arterial Disease/epidemiology , Prospective Studies , Registries , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Young Adult
18.
J Endovasc Ther ; 27(4): 658-665, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32419597

ABSTRACT

Purpose: To evaluate the midterm results of patients suffering from no-option chronic limb-threatening ischemia (CLTI) treated with a dedicated system for percutaneous deep venous arterialization (pDVA). Materials and Methods: Thirty-two consecutive CLTI patients (mean age 67±14 years; 20 men) treated with pDVA using the Limflow device at 4 centers between 11 July 2014 and 11 June 2018 were retrospectively analyzed. Of all patients, 21 (66%) had diabetes, 8 (25%) were on immunosuppression, 4 (16%) had dialysis-dependent renal failure, 9 (28%) had Rutherford category 6 ischemia, and 25 (78%) were deemed at high risk of amputation. The primary outcome was amputation-free survival (AFS) at 6 months. Secondary outcomes were wound healing, limb salvage, and survival at 6, 12, and 24 months. Results: Technical success was achieved in 31 patients (96.9%). The median follow-up was 34 months (range 16-63). At 6, 12, and 24 months, estimates were 83.9%, 71.0%, and 67.2% for AFS, 86.8%, 79.8% and 79.8% for limb salvage, and 36.6%, 68.2%, and 72.7% for complete wound healing, respectively. Median time to complete wound healing was 4.9 months (range 0.5-15). The DVA circuit occluded during follow-up in 21 patients; the median time to occlusion was 2.6 months. Reintervention for occlusion was performed in 17 patients: 16 because of unhealed wounds and 1 for a newly developed ulcer. Conclusion: This study represents the largest population of patients with no-option CLTI treated with pDVA using the LimFlow device with midterm results. In this complex group of patients, pDVA using the LimFlow device has been shown to be feasible, with a high technical success rate and AFS at 6 up to 24 months coupled with wound healing. In selected patients with no-option CLTI, pDVA could be a recommended treatment to prevent amputation and heal wounds.


Subject(s)
Endovascular Procedures/instrumentation , Ischemia/surgery , Peripheral Vascular Diseases/surgery , Aged , Aged, 80 and over , Amputation, Surgical , Chronic Disease , Endovascular Procedures/adverse effects , Female , Humans , Ischemia/diagnostic imaging , Ischemia/physiopathology , Limb Salvage , Male , Middle Aged , Peripheral Vascular Diseases/diagnostic imaging , Peripheral Vascular Diseases/physiopathology , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , Vascular Patency , Wound Healing
19.
J Endovasc Ther ; 27(4): 547-564, 2020 08.
Article in English | MEDLINE | ID: mdl-32571125

ABSTRACT

Endovascular revascularization has been increasingly utilized to treat patients with chronic limb-threatening ischemia (CLTI), particularly atherosclerotic disease in the infrapopliteal arteries. Lesions of the infrapopliteal arteries are the result of 2 different etiologies: medial calcification and intimal atheromatous plaque. Although several devices are available for endovascular treatment of infrapopliteal lesions, balloon angioplasty still comprises the mainstay of therapy due to a lack of purpose-built devices. The mechanism of balloon angioplasty consists of adventitial stretching, medial necrosis, and dissection or plaque fracture. In many cases, the diffuse nature of infrapopliteal disease and plaque complexity may lead to dissection, recoil, and early restenosis. Optimal balloon angioplasty requires careful attention to assessment of vessel calcification, appropriate vessel sizing, and the use of long balloons with prolonged inflation times, as outlined in a treatment algorithm based on this systematic review. Further development of specific devices for this arterial segment are warranted, including devices for preventing recoil (eg, dedicated atherectomy devices), treating dissections (eg, tacks, stents), and preventing neointimal hyperplasia (eg, novel drug delivery techniques and drug-eluting stents). Further understanding of infrapopliteal disease, along with the development of new technologies, will help optimize the durability of endovascular interventions and ultimately improve the limb-related outcomes of patients with CLTI.


Subject(s)
Algorithms , Angioplasty, Balloon , Decision Support Techniques , Ischemia/therapy , Peripheral Arterial Disease/therapy , Popliteal Artery , Amputation, Surgical , Angioplasty, Balloon/adverse effects , Angioplasty, Balloon/instrumentation , Angioplasty, Balloon/mortality , Chronic Disease , Clinical Decision-Making , Humans , Ischemia/diagnostic imaging , Ischemia/mortality , Ischemia/physiopathology , Limb Salvage , Patient Selection , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/mortality , Peripheral Arterial Disease/physiopathology , Popliteal Artery/diagnostic imaging , Popliteal Artery/physiopathology , Recurrence , Risk Factors , Treatment Outcome , Vascular Patency
20.
J Endovasc Ther ; 27(2): 175-185, 2020 04.
Article in English | MEDLINE | ID: mdl-32066315

ABSTRACT

PURPOSE: To report the risk of all-cause mortality after treatment with paclitaxel-coated devices vs uncoated controls in patients with chronic limb-threatening ischemia (CLTI). MATERIALS AND METHODS: A search of the PubMed, Embase, Cochrane, CINAHL, DARE, and PROSPERO databases was made on 5 November 2019 to identify randomized controlled trials (RCT) using intention-to-treat analysis to compare a paclitaxel-coated device to an uncoated device in PAD patients having clinical follow-up of at least 6 months. Half of the study population had to have CLTI or extractable data on the CLTI subgroup if <50%. The search identified 11 trials having 1450 patients randomized to a paclitaxel-coated device (n=866) or an uncoated control (n=584). There were 1367 (94.3%) patients with CLTI (range 10-429). The single endpoint was all-cause mortality, which was analyzed by pooling the mortality data in a DerSimonian and Laird random effects model. Summary statistics are expressed as relative risk ratios (RR) with a 95% confidence interval (CI). RESULTS: The mean follow-up was 25.6 months (range 6-60); 10 of 11 studies reported a minimum 12-month follow-up. There were 161 (18.6%) deaths among 866 subjects in the paclitaxel device group and 116 deaths among 584 (19.9%) subjects in the non-coated control group (RR 0.93, 95% CI 0.78 to 1.12, p=0.45). CONCLUSION: There was no observed difference in short- to midterm mortality among a pooled patient population of predominately CLTI patients treated with paclitaxel-coated balloons or stents compared with uncoated controls.


Subject(s)
Angioplasty, Balloon/instrumentation , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Drug-Eluting Stents , Ischemia/therapy , Paclitaxel/administration & dosage , Peripheral Arterial Disease/therapy , Vascular Access Devices , Aged , Angioplasty, Balloon/adverse effects , Angioplasty, Balloon/mortality , Cardiovascular Agents/adverse effects , Cause of Death , Chronic Disease , Female , Humans , Ischemia/diagnosis , Ischemia/mortality , Ischemia/physiopathology , Male , Paclitaxel/adverse effects , Peripheral Arterial Disease/diagnosis , Peripheral Arterial Disease/mortality , Peripheral Arterial Disease/physiopathology , Prosthesis Design , Randomized Controlled Trials as Topic , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL