1.
J Clin Monit Comput ; 35(1): 113-121, 2021 Feb.
Article in English | MEDLINE | ID: mdl-31902095

ABSTRACT

Multispectral imaging (MSI) is a new, non-invasive method to continuously measure oxygenation and microcirculatory perfusion, but has limitedly been validated in healthy volunteers. The present study aimed to validate the potential of multispectral imaging in the detection of microcirculatory perfusion disturbances during a vascular occlusion test (VOT). Two consecutive VOT's were performed on healthy volunteers and tissue oxygenation was measured with MSI and near-infrared spectroscopy (NIRS). Correlations between the rate of desaturation, recovery and the hyperemic area under the curve (AUC) measured by MSI and NIRS were calculated. Fifty-eight volunteers were included. The MSI oxygenation curves showed identifiable components of the VOT, including a desaturation and recovery slope and hyperemic area under the curve, similar to those measured with NIRS. The correlation between the rate of desaturation measured by MSI and NIRS was moderate: r = 0.42 (p = 0.001) for the first and r = 0.41 (p = 0.002) for the second test. Our results suggest that non-contact multispectral imaging is able to measure changes in regional oxygenation and deoxygenation during a vascular occlusion test in healthy volunteers. When compared to measurements with NIRS, correlation of results was moderate to weak, most likely reflecting differences in physiology of the regions of interest and measurement technique.


Subject(s)
Spectroscopy, Near-Infrared , Vascular Diseases , Healthy Volunteers , Humans , Microcirculation , Oxygen Consumption , Perfusion
2.
Lasers Med Sci ; 35(6): 1357-1365, 2020 Aug.
Article in English | MEDLINE | ID: mdl-31984457

ABSTRACT

Different devices have been used to enhance topical drug delivery. Aim of this study was to compare the efficacy of different skin pretreatment regimens in topical drug delivery. In six ex vivo human abdominal skin samples, test regions were pretreated with fractional CO2 and Er:YAG laser (both 70 and 300 µm ablation depth, density of 5%), microneedling (500 µm needle length), fractional radiofrequency (ablation depth of ± 80-90 µm), and no pretreatment. The fluorescent agent indocyanine green (ICG) was applied. After 3 h, fluorescence intensity was measured at several depths using fluorescence photography. Significantly higher surface fluorescence intensities were found for pretreatment with fractional Er:YAG and CO2 laser and for microneedling vs. no pretreatment (p < 0.05), but not for radiofrequency vs. no pretreatment (p = 0.173). Fluorescence intensity was highest for the Er:YAG laser with 300 µm ablation depth (mean 38.89 arbitrary units; AU), followed by microneedling (33.02 AU) and CO2 laser with 300 µm ablation depth (26.25 AU). Pretreatment with both lasers with 300 µm ablation depth gave higher fluorescence intensity than with 70 µm ablation depth (Er:YAG laser, 21.65; CO2 laser, 18.50 AU). Mean fluorescence intensity for radiofrequency was 15.27 AU. Results were comparable at 200 and 400 µm depth in the skin. Pretreatment of the skin with fractional CO2 laser, fractional Er:YAG laser, and microneedling is effective for topical ICG delivery, while fractional radiofrequency is not. Deeper laser ablation results in improved ICG delivery. These findings may be relevant for the delivery of other drugs with comparable molecular properties.


Subject(s)
Drug Delivery Systems , Indocyanine Green/administration & dosage , Lasers, Gas/therapeutic use , Lasers, Solid-State/therapeutic use , Needles , Radiofrequency Ablation , Administration, Cutaneous , Fluorescence , Humans , Indocyanine Green/pharmacology , Skin/drug effects , Skin/radiation effects , Tomography, Optical Coherence
3.
J Sex Med ; 16(5): 746-754, 2019 May.
Article in English | MEDLINE | ID: mdl-30926514

ABSTRACT

INTRODUCTION: Hormone treatment induces feminization of the body in transwomen and masculinization in transmen. However, the effect of hormone treatment on facial characteristics is still unknown. AIM: We aimed to study whether hormone treatment induces facial feminization and masculinization and how this potential change affects satisfaction and self-esteem. METHODS: In this single-center cohort study, we included 27 transwomen and 15 transmen who received standardized hormone treatment in the Center of Expertise on Gender Dysphoria, VU University Medical Center Amsterdam. Facial 3-dimensional images were obtained at baseline and at 3 and 12 months. At each image, 22 facial landmarks were placed. Furthermore, the FACE-Q Satisfaction with Facial Appearance Overall and the Rosenberg self-esteem scale were obtained at the same measurement points. MAIN OUTCOME MEASURES: The main outcome measures included the relative local shift of skin in millimeters in the 22 landmarks in the transverse (x-axis), coronal (y-axis), and sagittal (z-axis) anatomic axes, the color maps, and the outcomes of the questionnaires. RESULTS: After 12 months, cheek tissue in transwomen increased, with 0.50 mm (95% CI 0.04-0.96) in the x-axis and 1.08 mm (95% CI 0.31-1.85) in the z-axis. Tissue in the jaws decreased with -0.60 mm (95% CI -1.28-0.08) in the x-axis and -0.18 mm (95% CI -0.03-0.33) in the y-axis. Cheek tissue in transmen decreased with -0.45 mm (95% CI -1.00-0.11) in the x-axis and -0.84 mm (95% CI -1.92-0.25) in the z-axis. These changes already started after 3 months. An increase in satisfaction with the facial appearance was found in both transwomen and transmen. There were no changes in reported self-esteem. CLINICAL IMPLICATION: These results could lead to more realistic expectations of facial changes. Furthermore, our results suggest that the face continues to change for at least a year, which could suggest that performing facial feminization surgery after 1 year of hormone treatment might be too early. STRENGTH & LIMITATIONS: This study is the first that provides insight into the facial changes in transgender individuals receiving hormone treatment, and it introduces an objective method to examine (small) facial changes. Our study is limited by the poor reliability of the landmarks, the difficulty of facial fixation, and the lack of gender-specific questions in the questionnaires. CONCLUSIONS: Hormone treatment in transwomen induces an increase in cheek tissue and a decrease in jaw tissue. In transmen a tendency of decrease in cheek tissue and an increase in jaw tissue was found. These changes are in the direction of the desired gender. Tebbens M, Nota NM, Liberton NPTJ, et al. Gender-Affirming Hormone Treatment Induces Facial Feminization in Transwomen and Masculinization in Transmen: Quantification by 3D Scanning and Patient-Reported Outcome Measures. J Sex Med 2019;16:746-754.


Subject(s)
Face/physiology , Gender Dysphoria/psychology , Hormones/administration & dosage , Transgender Persons/psychology , Adult , Cohort Studies , Female , Feminization , Humans , Male , Patient Reported Outcome Measures , Personal Satisfaction , Pilot Projects , Prospective Studies , Reproducibility of Results , Self Concept , Surveys and Questionnaires , Young Adult
4.
Lasers Surg Med ; 51(8): 709-719, 2019 10.
Article in English | MEDLINE | ID: mdl-30908718

ABSTRACT

BACKGROUND AND OBJECTIVES: Topical drug delivery can be increased by pretreatment of the skin with ablative fractional laser (AFXL). Several physical penetration enhancement techniques have been investigated to further improve AFXL-assisted drug delivery. This study investigated the influence of three of these techniques, namely massage, acoustic pressure wave treatment, and pressure vacuum alterations (PVP) on the distribution of the fluorescent drug indocyanine green (ICG) at different depths in the skin after topical application on AFXL pretreated skin. MATERIALS AND METHODS: In ex vivo human skin, test regions were pretreated with AFXL (10,600 nm, channel depth 300 µm, channel width 120 µm, density 15%). Subsequently, ICG was applied, followed by massage, acoustic pressure wave treatment or PVP. ICG fluorescence intensity (FI) was assessed after 1, 3, and 24 hours at several depths using fluorescence photography. RESULTS: FI was higher when using enhancement techniques compared to control (AFXL-only) up to 3 hours application time (P < 0.05). After 3 hours, mean surface FI was highest after acoustic pressure wave treatment (61.5 arbitrary units; AU), followed by massage (57.5AU) and PVP (46.9AU), respectively (for comparison: AFXL-only 31.6AU, no pretreatment 14.9AU). Comparable or higher FI was achieved already after 1 hour with enhancement techniques compared to 3-24 hours application time without. After 24 hours, no significant differences between enhancement techniques and AFXL-only were observed (P = 0.31). CONCLUSION: Penetration enhancement techniques, especially acoustic pressure wave treatment and massage, result in improved drug accumulation in AFXL-pretreated skin and reduce the application time needed. Lasers Surg. Med. © 2019 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.


Subject(s)
Drug Delivery Systems/methods , Indocyanine Green/pharmacology , Laser Therapy , Skin Absorption/drug effects , Administration, Cutaneous , Fluorescence , Hospitals, Urban , Humans , In Vitro Techniques , Netherlands , Sampling Studies , Sensitivity and Specificity , Statistics, Nonparametric
5.
Sensors (Basel) ; 19(21)2019 Nov 05.
Article in English | MEDLINE | ID: mdl-31694239

ABSTRACT

Comparing and selecting an adequate spectral filter array (SFA) camera is application-specific and usually requires extensive prior measurements. An evaluation framework for SFA cameras is proposed and three cameras are tested in the context of skin analysis. The proposed framework does not require application-specific measurements and spectral sensitivities together with the number of bands are the main focus. An optical model of skin is used to generate a specialized training set to improve spectral reconstruction. The quantitative comparison of the cameras is based on reconstruction of measured skin spectra, colorimetric accuracy, and oxygenation level estimation differences. Specific spectral sensitivity shapes influence the results directly and a 9-channel camera performed best regarding the spectral reconstruction metrics. Sensitivities at key wavelengths influence the performance of oxygenation level estimation the strongest. The proposed framework allows to compare spectral filter array cameras and can guide their application-specific development.


Subject(s)
Photography/instrumentation , Skin Diseases/diagnosis , Spectrum Analysis , Computer Simulation , Humans , Monte Carlo Method , Oxygen/metabolism , Principal Component Analysis , Reproducibility of Results
6.
J Clin Monit Comput ; 32(2): 335-341, 2018 Apr.
Article in English | MEDLINE | ID: mdl-28508148

ABSTRACT

Due to the high rates of epidural failure (3-32%), novel techniques are required to objectively assess the successfulness of an epidural block. In this study we therefore investigated whether thermographic temperature measurements have a higher predictive value for a successful epidural block when compared to the cold sensation test as gold standard. Epidural anesthesia was induced in 61 patients undergoing elective abdominal, thoracic or orthopedic surgery. A thermographic picture was recorded at 5, 10 and 15 min following epidural anesthesia induction. After 15 min a cold sensation test was performed. Epidural anesthesia is associated with a decrease in skin temperature. Thermography predicts a successful epidural block with a sensitivity of 54% and a PPV of 92% and a specificity of 67% and a NPV of 17%. The cold sensation test shows a higher sensitivity and PPV than thermography (97 and 93%), but a lower specificity and NPV than thermography (25 and 50%). Thermographic temperature measurements can be used as an additional and objective method for the assessment of the effectiveness of an epidural block next to the cold sensation test, but have a low sensitivity and negative predictive value. The local decrease in temperature as observed in our study during epidural anesthesia is mainly attributed to a core-to-peripheral redistribution of body heat and vasodilation.


Subject(s)
Anesthesia, Epidural/methods , Cold Temperature , Skin Temperature , Skin/pathology , Thermography/methods , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Sensitivity and Specificity , Sensory Thresholds , Vasodilation
7.
Lasers Surg Med ; 2017 Dec 07.
Article in English | MEDLINE | ID: mdl-29214660

ABSTRACT

BACKGROUND AND OBJECTIVE: Endoscopic third ventriculostomy is used to treat hydrocephalus. Different laser wavelengths have been proposed for laser-assisted endoscopic third ventriculostomies over the last decades. The aim of this study was to evaluate Thulium laser endoscopic third ventriculostomy heat penetration in the surrounding environment of the floor of the third ventricle in an in vitro setting with visualization of thermal distribution. Subsequently 106 Thulium laser endoscopic third ventriculostomy procedures were retrospectively analyzed to demonstrate safety. METHODS: The in vitro visualization was based on the color Schlieren method. The heat penetration was measured beneath a tissue phantom of the floor of the third ventricle with a fiber of 365 µm in diameter at different energy settings; 1.0W (956 J/cm2 ), 2.0W (1,912 J/cm2 ), 4.0W (3,824 J/cm2 ), and 7.0W (6,692 J/cm2 ), with a pulse duration of 1.0 second. All experiments were repeated five times. In addition, 106 Thulium laser endoscopic third ventriculostomy procedures between 2005 and 2015 were retrospectively analysed for etiology, sex, complications, and laser parameters. RESULTS: In the energy settings from 1.0 to 4.0 W, heat penetration depth beneath the phantom of the third ventricle did not exceed 1.5 mm. The heat penetration depth at 7 W, exceeded 6 mm. The clinical overall success rate was 80% at the 2-year follow-up study. Complications occurred in 5% of the procedures. In none of the 106 investigated clinical patients bleeding or damage to the basilar artery was encountered due to Thulium laser ablation. CONCLUSIONS: The in vitro experiments show that under 4.0W the situation is considered safe, due to low penetration of heat, thus the chance of accidentally damaging critical structures like the basilar artery is very small. The clinical results show that the Thulium laser did not cause any bleeding of the basilar artery, and is a safe technique for laser endoscopic third ventriculostomy. Lasers Surg. Med. © 2017 Wiley Periodicals, Inc.

8.
J Vasc Interv Radiol ; 27(3): 433-43, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26703782

ABSTRACT

PURPOSE: Irreversible electroporation (IRE) uses high-voltage electric fields to achieve cell death. Although the mechanism of IRE is mainly designated as nonthermal, development of secondary Joule heating is inevitable. The study purpose was to gain understanding of temperature development and distribution during IRE. MATERIALS AND METHODS: IRE was performed in a transparent polyacrylamide gel resembling soft tissue. Mechanical effects, changes in temperature gradient, and absolute temperature changes were measured with three different optical techniques (high-speed, color Schlieren, and infrared imaging) to investigate the effect on temperature of variations in voltage, pulse length, active tip length (ATL), interelectrode distance, electrode configuration (parallel, convergent, and divergent), and sequential pulsing (pulse delivery interrupted by breaks). The total delivered energy was calculated. RESULTS: A temperature gradient, starting at the tips of both electrodes and expanding toward each other, developed immediately with pulse delivery. Temperatures increased with increasing voltage (by 2.5°C-40.4°C), pulse length (by 5.3°C-9.8°C), ATL (by 5.9°C-17.6°C), and interelectrode distance (by 7.6°C-21.5°C), in accordance with higher energy delivery. Nonparallel electrode placement resulted in heterogeneous temperature distribution with the peak temperature focused in the area with the shortest interelectrode distance. Sequential pulse delivery significantly reduced the temperature increase compared with continuous pulsing (4.3°C vs 11.7°C). CONCLUSIONS: Voltage, pulse length, interelectrode distance, ATL, and electrode configuration each have a strong effect on temperature development and distribution during IRE. Sequential pulsing reduces the extent and volume of thermal distribution and may prove beneficial with respect to procedural safety.


Subject(s)
Ablation Techniques , Acrylic Resins/chemistry , Electroporation , Hot Temperature , Electric Conductivity , Energy Transfer , Gases , Models, Anatomic , Thermography , Time Factors , Video Recording
9.
Brain Topogr ; 28(4): 606-18, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25315607

ABSTRACT

Spatial independent component analysis (ICA) is increasingly being used to extract resting-state networks from fMRI data. Previous studies showed that ICA also reveals independent components (ICs) related to the seizure onset zone. However, it is currently unknown how these epileptic ICs depend on the presence of interictal epileptic discharges (IEDs) in the EEG. The goal of this study was to explore the relation between ICs obtained from fMRI epochs during the occurrence of IEDs in the EEG and those without IEDs. fMRI data sets with co-registered EEG were retrospectively selected of patients from whom the location of the epileptogenic zone was confirmed by outcome of surgery (n = 8). The fMRI data were split into two epochs: one with IEDs visible in scalp EEG and one without. Spatial ICA was applied to the fMRI data of each part separately. The maps of all resulting components were compared to the resection area and the EEG-fMRI correlation pattern by computing a spatial correlation coefficient to detect the epilepsy-related component. For all patients, except one, there was a remarkable resemblance between the epilepsy-related components selected during epochs with IEDs and those without IEDs. These findings suggest that epilepsy-related ICs are not dependent on the presence of IEDs in scalp EEG. Since these epileptic ICs showed partial overlap with resting-state networks of healthy volunteers (n = 10), our study supports the need for new ways to classify epileptic ICs.


Subject(s)
Brain Mapping/methods , Brain/physiopathology , Electroencephalography/methods , Epilepsy/physiopathology , Magnetic Resonance Imaging/methods , Adult , Epilepsy/diagnosis , Female , Humans , Male , Middle Aged , Scalp/physiology , Young Adult
10.
Lasers Med Sci ; 29(2): 501-7, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24338133

ABSTRACT

Many different types of fiber tips have been developed over the last few years to be used in endovenous laser ablation (EVLA) procedures. All these new but different tips claim a certain superiority over the other tips. Evidence for a best tip is however lacking. Four of these fiber tips have been compared in this article: (1) the bare fiber, (2) the Tulip-Tip, (3) the NeverTouch™ tip, and (4) the radially emitting tip. The aim of this paper is to provide information on the technical differences between these fiber tips and differences in their underlying heat transfer mechanisms. Although all tips are effective in the primary goal of EVLA, namely to occlude the incompetent vein, they differ in side effects, they differ in side effects, practicality, and cost. Although these new tips have improved EVLA, the perfect tip is not on the market yet.


Subject(s)
Laser Therapy/instrumentation , Laser Therapy/methods , Varicose Veins/surgery , Endovascular Procedures/instrumentation , Endovascular Procedures/methods , Equipment Design , Fiber Optic Technology , Hot Temperature , Humans , Veins/anatomy & histology
11.
Eur Arch Otorhinolaryngol ; 271(6): 1477-83, 2014 Jun.
Article in English | MEDLINE | ID: mdl-23880918

ABSTRACT

High-speed thermal imaging enables visualization of heating of the vestibule during laser-assisted stapedotomy, comparing KTP, CO2, and Thulium laser light. Perforation of the stapes footplate with laser bears the risk of heating of the inner ear fluids. The amount of heating depends on absorption of the laser light and subsequent tissue ablation. The ablation of the footplate is driven by strong water absorption for the CO2 and Thulium laser. For the KTP laser wavelength, ablation is driven by carbonization of the footplate and it might penetrate deep into the inner ear without absorption in water. The thermal effects were visualized in an inner ear model, using two new techniques: (1) high-speed Schlieren imaging shows relative dynamic changes of temperatures up to 2 ms resolution in the perilymph. (2) Thermo imaging provides absolute temperature measurements around the footplate up to 40 ms resolution. The high-speed Schlieren imaging showed minimal heating using the KTP laser. Both CO2 and Thulium laser showed heating below the footplate. Thulium laser wavelength generated heating up to 0.6 mm depth. This was confirmed with thermal imaging, showing a rise of temperature of 4.7 (±3.5) °C for KTP and 9.4 (±6.9) for Thulium in the area of 2 mm below the footplate. For stapedotomy, the Thulium and CO2 laser show more extended thermal effects compared to KTP. High-speed Schlieren imaging and thermal imaging are complimentary techniques to study lasers thermal effects in tissue.


Subject(s)
Hot Temperature , Lasers, Gas/therapeutic use , Lasers, Solid-State/therapeutic use , Otosclerosis/surgery , Perilymph , Stapes Mobilization/methods , Thulium , Humans , Models, Anatomic , Stapes Mobilization/instrumentation
12.
PLoS One ; 19(6): e0305059, 2024.
Article in English | MEDLINE | ID: mdl-38843166

ABSTRACT

Three-dimensional (3D) imaging techniques are promising new tools for measuring breast volume, for example in gender-affirming therapy. Transgender individuals can be treated with gender-affirming hormone therapy (GAHT). A robust method for monitoring breast volume changes is critical to be able to study the effects of feminizing GAHT. The primary aim of this study was to compare the accuracy of three 3D devices (Vectra XT, Artec LEO and iPhone XR) for measuring modest breast volume differences using a mannequin. The secondary aim of this study was to evaluate these methods in several performance domains. We used reference prostheses of increasing volumes and compared the volumes using GOM-inspect software. For Vectra XT 3D images, manufacturer-provided software was used to calculate volumes as well. The scanning methods were ranked based on their performance in a total of five categories: volume estimations, costs, user-friendliness, test subject-friendliness and technical aspects. The 3D models analyzed with GOM-inspect showed relative mean estimate differences from the actual volumes of 9.1% for the Vectra XT, 7.3% for the Artec LEO and 14% for the iPhone XR. For the Vectra XT models analyzed with the built-in software this was 6.2%. Root mean squared errors (RMSE) calculated based on the GOM-inspect volume analyses showed mean RMSEs of 2.27, 2.54 and 8.93 for the Vectra XT, Artec LEO and iPhone XR, respectively. The Vectra software had a mean RMSE of 3.00. In the combined performance ranking, the Vectra XT had the most favorable ranking, followed by the Artec LEO and the iPhone XR. The Vectra XT and Artec LEO are the preferred scanners to monitor breast development due to the combination of higher accuracy and overall performance. The current study shows that 3D techniques can be used to adequately measure modest breast volume differences and therefore will be useful to study for example breast changes in transgender individuals using feminizing GAHT. These observations may also be relevant in other fields of 3D imaging research.


Subject(s)
Breast , Imaging, Three-Dimensional , Humans , Female , Breast/diagnostic imaging , Imaging, Three-Dimensional/methods , Male , Software , Organ Size , Manikins , Transgender Persons
13.
JMIR Nurs ; 7: e56474, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38781012

ABSTRACT

Technology has a major impact on the way nurses work. Data-driven technologies, such as artificial intelligence (AI), have particularly strong potential to support nurses in their work. However, their use also introduces ambiguities. An example of such a technology is AI-driven lifestyle monitoring in long-term care for older adults, based on data collected from ambient sensors in an older adult's home. Designing and implementing this technology in such an intimate setting requires collaboration with nurses experienced in long-term and older adult care. This viewpoint paper emphasizes the need to incorporate nurses and the nursing perspective into every stage of designing, using, and implementing AI-driven lifestyle monitoring in long-term care settings. It is argued that the technology will not replace nurses, but rather act as a new digital colleague, complementing the humane qualities of nurses and seamlessly integrating into nursing workflows. Several advantages of such a collaboration between nurses and technology are highlighted, as are potential risks such as decreased patient empowerment, depersonalization, lack of transparency, and loss of human contact. Finally, practical suggestions are offered to move forward with integrating the digital colleague.


Subject(s)
Artificial Intelligence , Life Style , Long-Term Care , Humans , Long-Term Care/methods , Aged , Monitoring, Physiologic/methods , Monitoring, Physiologic/instrumentation , Female
14.
Cancers (Basel) ; 15(17)2023 Aug 26.
Article in English | MEDLINE | ID: mdl-37686556

ABSTRACT

Unintentional local temperature effects can occur during irreversible electroporation (IRE) treatment, especially near the electrodes, and most frequently near the tip. Partial electrical insulation of the IRE electrodes could possibly control these temperature effects. This study investigated and visualized the effect of partial electrical insulation applied to the IRE electrodes on the electric field line pattern and temperature gradient. Six designs of (partial) electrical insulation of the electrode tip and/or active needle length (ANL) of the original monopolar 19G IRE electrodes were investigated. A semolina in castor oil model was used to visualize the electric field line pattern in a high-voltage static electric field. An optical method to visualize a change in temperature gradient (color Schlieren) was used to image the temperature development in a polyacrylamide gel. Computational models were used to support the experimental findings. Around the electrode tip, the highest electric field line density and temperature gradient were present. The more insulation was applied to the electrodes, the higher the resistance. Tip and ANL insulation together reduced the active area of and around the electrodes, resulting in a visually enlarged area that showed a change in temperature gradient. Electrically insulating the electrode tip together with an adjustment in IRE parameter settings could potentially reduce the uncontrollable influence of the tip and may improve the predictability of the current pathway development.

15.
Paediatr Anaesth ; 22(3): 223-9, 2012 Mar.
Article in English | MEDLINE | ID: mdl-21851476

ABSTRACT

BACKGROUND: It is generally believed that certain patient characteristics (e.g., Body Mass Index and age) predict difficulty of intravenous cannulation in children, but there is not much literature evaluating these risk factors. In this study, we investigated predictive factors for success rate at first attempt and time needed for intravenous cannulation. METHODS/MATERIALS: In a prospective cohort study, we observed characteristics of intravenous cannulations in pediatric patients at the operating room (n = 1083) and the outpatient care unit (n = 178) of a tertiary referral pediatric hospital. Time to successful intravenous cannulation, success at first attempt, and potential predictors for difficult cannulation (age, gender, skin color, BMI or weight-to-age z-score, the child being awake or anesthetized, operator profession and surgical specialty) were recorded. Regression models were constructed to find significant predictors. RESULTS: Success at first attempt was 73% and 81%, respectively. In the operating room age, operator and surgical specialty were predictive for a successful first attempt and time to successful cannulation. No significant predictive factors were found for the outpatient care unit. BMI or weight-to-age was not related to difficult intravenous cannulation. CONCLUSIONS: This study shows that in one-fifth to one-third of the patients, intravenous cannulation required more than one attempt. It is difficult to predict with accuracy the difficulty of intravenous cannulation solely with easily obtainable patient characteristics.


Subject(s)
Catheterization, Peripheral/adverse effects , Adolescent , Age Factors , Anesthesia , Anesthesia, Local , Anesthesiology , Body Mass Index , Child , Child, Preschool , Cohort Studies , Female , Hospitals, Pediatric , Humans , Infant, Newborn , Lidocaine , Lidocaine, Prilocaine Drug Combination , Male , Nurse Anesthetists , Odds Ratio , Outpatients , Prilocaine , Prospective Studies , Regression Analysis , Risk Factors , Skin Pigmentation , Specialties, Surgical , Treatment Outcome
16.
J Voice ; 2022 Apr 10.
Article in English | MEDLINE | ID: mdl-35418349

ABSTRACT

OBJECTIVE: To determine the differences in thermal effects on vocal folds between four fiber-routed lasers. METHODS: In this experimental laboratory study the thermal effects of an AcuPulse Duo CO2 (CO2 AP), UltraPulse Duo CO2 (CO2 UP), KTP, and Blue laser were analyzed using a Schlieren technique on a human tissue mimicking gel model. Power, laser duration, laser fiber distance to tissue and mode (continuous wave [CW] vs pulsed [P] modes) were evaluated in varying combinations in order to compare the effects of the tested lasers and to explore the individual effect on thermal expansion and incision depth of each setting. The model was validated by comparing the results from the Schlieren model with histology of ex vivo fresh human vocal folds after laser irradiation using a selection of the same laser settings, and calculating the intraclass correlation coefficient (ICC). RESULTS: One thousand ninety-eight Schlieren experiments and 56 vocal cord experiments were conducted. In comparison with CW mode, less thermal expansion occurred in P mode in all lasers, while incisions were deeper in the CO2 and more superficial in the KTP and Blue lasers. The mean thermal expansion was found to be minimally smaller, whereas incision depth was pronouncedly smaller in the KTP and Blue compared to the CO2 lasers. Duration of laser irradiation was the most important factor of influence on thermal expansion and incision depth for all lasers in both CW and P modes. The ICC for consistency between the results of the Schlieren model and the vocal cord histology was classified from fair to excellent, except for the thermal expansion of the Blue laser, which was classified as poor. CONCLUSION: This study demonstrates important differences in thermal effects between CO2, KTP, and Blue lasers which can be explained by the different physical characteristics of the P modes and divergence of the fiber delivery system. The Schlieren imaging model is a good predictor of the relative thermal effects in vocal fold tissue. Our results can be used as a guidance for ENT surgeons using fiber-routed lasers, in order to achieve effective treatment of vocal fold lesions and prevention of functional impairment of vocal folds.

17.
Laryngoscope ; 130(11): E680-E685, 2020 11.
Article in English | MEDLINE | ID: mdl-32022931

ABSTRACT

OBJECTIVES/HYPOTHESIS: To provide insight in the thermal effects of individual laser settings in target tissues to optimize flexible endoscopic CO2 laser surgery treatment. STUDY DESIGN: Experimental laboratory study. METHODS: Thermal effects of the CO2 laser using a fiber delivery system were visualized using the color Schlieren technique in combination with a polyacrylamide gel tissue model. Variable settings were used for emission mode, power, laser fiber distance, and laser duration, which were evaluated in every possible combination. Collateral thermal expansion and incision depth were measured. To validate the model, the results were compared to histology after CO2 laser irradiation of ex vivo human vocal cords, and the intraclass correlation coefficient was calculated. Thermal damage and incision depth were measured by a blinded pathologist. RESULTS: Of all parameters studied, duration of laser irradiation had the greatest effect on thermal expansion. Increased distance between laser tip and target tissue resulted in significantly reduced incision depth and increased thermal expansion. Pulsed emission modes led to increased incision depths. The intraclass correlation coefficient for consistency between the model setup and the ex vivo human vocal cords was classified as "fair." CONCLUSIONS: By using high-intensity pulsed lasers at minimal distance to the target tissue, exposure times and subsequent damage to surrounding tissue can be reduced. If an evaporation technique is used, lower power in continuous wave at a larger distance to the target tissue will lead to superficial but broader thermal effects. The model setup used in this study is a valid model to investigate laser-induced thermal effects in vocal cord tissue. LEVEL OF EVIDENCE: NA Laryngoscope, 130:E680-E685, 2020.


Subject(s)
Ambulatory Surgical Procedures/methods , Laryngoscopy/methods , Lasers, Gas/therapeutic use , Models, Anatomic , Vocal Cords/surgery , Carbon Dioxide , Humans , Thermal Conductivity
18.
J Imaging ; 5(8)2019 Jul 26.
Article in English | MEDLINE | ID: mdl-34460500

ABSTRACT

The emerging technology of spectral filter array (SFA) cameras has great potential for clinical applications, due to its unique capability for real time spectral imaging, at a reasonable cost. This makes such cameras particularly suitable for quantification of dynamic processes such as skin oxygenation. Skin oxygenation measurements are useful for burn wound healing assessment and as an indicator of patient complications in the operating room. Due to their unique design, in which all pixels of the image sensor are equipped with different optical filters, SFA cameras require specific image processing steps to obtain meaningful high quality spectral image data. These steps include spatial rearrangement, SFA interpolations and spectral correction. In this paper the feasibility of a commercially available SFA camera for clinical applications is tested. A suitable general image processing pipeline is proposed. As a 'proof of concept' a complete system for spatial dynamic skin oxygenation measurements is developed and evaluated. In a study including 58 volunteers, oxygenation changes during upper arm occlusion were measured with the proposed SFA system and compared with a validated clinical device for localized oxygenation measurements. The comparison of the clinical standard measurements and SFA results show a good correlation for the relative oxygenation changes. This proposed processing pipeline for SFA cameras shows to be effective for relative oxygenation change imaging. It can be implemented in real time and developed further for absolute spatial oxygenation measurements.

20.
J Biomed Opt ; 11(4): 041110, 2006.
Article in English | MEDLINE | ID: mdl-16965138

ABSTRACT

A setup based on color Schlieren techniques has been developed to study the interaction of energy sources, such as lasers, with biological tissues. This imaging technique enables real-time visualization of dynamic temperature gradients with high spatial and temporal resolution within a transparent tissue model. High-speed imaging techniques were combined in the setup to capture mechanical phenomena such as explosive vapor, cavitation bubbles, and shock waves. The imaging technique is especially used for qualitative studies because it is complex to obtain quantitative data by relating the colors in the images to temperatures. By positioning thermocouples in the field of view, temperature figures can be added in the image for correlation to colored areas induced by the temperature gradients. The color Schlieren setup was successfully used for various studies to obtain a better understanding of interaction of various laser, rf, and ultrasound devices used in medicine. The results contributed to the safety and the optimal settings of various medical treatments. Although the interaction of energy sources is simulated in model tissue, the video clips have proven to be of great value for educating researchers, surgeons, nurses, and students to obtain a better understanding of the mechanism of action during patient treatment.


Subject(s)
Diagnostic Imaging/instrumentation , Laser Therapy/education , Laser Therapy/instrumentation , Models, Biological , Optics and Photonics/instrumentation , Phantoms, Imaging , Research/instrumentation , Biomechanical Phenomena , Body Temperature/physiology , Equipment Design , Equipment Failure Analysis , Humans