Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 55
Filter
Add more filters

Publication year range
1.
Clin Chem Lab Med ; 61(2): 302-310, 2023 01 27.
Article in English | MEDLINE | ID: mdl-36395058

ABSTRACT

OBJECTIVES: During 2020, the UK's Department of Health and Social Care (DHSC) established the Moonshot programme to fund various diagnostic approaches for the detection of SARS-CoV-2, the pathogen behind the COVID-19 pandemic. Mass spectrometry was one of the technologies proposed to increase testing capacity. METHODS: Moonshot funded a multi-phase development programme, bringing together experts from academia, industry and the NHS to develop a state-of-the-art targeted protein assay utilising enrichment and liquid chromatography tandem mass spectrometry (LC-MS/MS) to capture and detect low levels of tryptic peptides derived from SARS-CoV-2 virus. The assay relies on detection of target peptides, ADETQALPQRK (ADE) and AYNVTQAFGR (AYN), derived from the nucleocapsid protein of SARS-CoV-2, measurement of which allowed the specific, sensitive, and robust detection of the virus from nasopharyngeal (NP) swabs. The diagnostic sensitivity and specificity of LC-MS/MS was compared with reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) via a prospective study. RESULTS: Analysis of NP swabs (n=361) with a median RT-qPCR quantification cycle (Cq) of 27 (range 16.7-39.1) demonstrated diagnostic sensitivity of 92.4% (87.4-95.5), specificity of 97.4% (94.0-98.9) and near total concordance with RT-qPCR (Cohen's Kappa 0.90). Excluding Cq>32 samples, sensitivity was 97.9% (94.1-99.3), specificity 97.4% (94.0-98.9) and Cohen's Kappa 0.95. CONCLUSIONS: This unique collaboration between academia, industry and the NHS enabled development, translation, and validation of a SARS-CoV-2 method in NP swabs to be achieved in 5 months. This pilot provides a model and pipeline for future accelerated development and implementation of LC-MS/MS protein/peptide assays into the routine clinical laboratory.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Pandemics , COVID-19/diagnosis , COVID-19 Testing , Tandem Mass Spectrometry/methods , Chromatography, Liquid , Prospective Studies , Clinical Laboratory Techniques/methods , Sensitivity and Specificity , Peptides
2.
Anal Chem ; 94(50): 17379-17387, 2022 12 20.
Article in English | MEDLINE | ID: mdl-36490367

ABSTRACT

The pandemic readiness toolbox needs to be extended, targeting different biomolecules, using orthogonal experimental set-ups. Here, we build on our Cov-MS effort using LC-MS, adding SISCAPA technology to enrich proteotypic peptides of the SARS-CoV-2 nucleocapsid (N) protein from trypsin-digested patient samples. The Cov2MS assay is compatible with most matrices including nasopharyngeal swabs, saliva, and plasma and has increased sensitivity into the attomole range, a 1000-fold improvement compared to direct detection in a matrix. A strong positive correlation was observed with qPCR detection beyond a quantification cycle of 30-31, the level where no live virus can be cultured. The automatable sample preparation and reduced LC dependency allow analysis of up to 500 samples per day per instrument. Importantly, peptide enrichment allows detection of the N protein in pooled samples without sensitivity loss. Easily multiplexed, we detect variants and propose targets for Influenza A and B detection. Thus, the Cov2MS assay can be adapted to test for many different pathogens in pooled samples, providing longitudinal epidemiological monitoring of large numbers of pathogens within a population as an early warning system.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19 Testing , Clinical Laboratory Techniques/methods , Mass Spectrometry/methods , Peptides , Sensitivity and Specificity
3.
Rapid Commun Mass Spectrom ; 36(13): e9308, 2022 Jul 15.
Article in English | MEDLINE | ID: mdl-35353398

ABSTRACT

RATIONALE: Analyte quantitation by mass spectrometry underpins a diverse range of scientific endeavors. The fast-growing field of mass spectrometer development has resulted in several targeted and untargeted acquisition modes suitable for these applications. By characterizing the acquisition methods available on an ion mobility (IM)-enabled orthogonal acceleration time-of-flight (oa-ToF) instrument, the optimum modes for analyte semi-quantitation can be deduced. METHODS: Serial dilutions of commercial metabolite, peptide, or cross-linked peptide analytes were prepared in matrices of human urine or Escherichia coli digest. Each analyte dilution was introduced into an IM separation-enabled oa-ToF mass spectrometer by reversed-phase liquid chromatography and electrospray ionization. Data were acquired for each sample in duplicate using nine different acquisition modes, including four IM-enabled acquisitions modes, available on the mass spectrometer. RESULTS: Five (metabolite) or seven (peptide/cross-linked peptide) point calibration curves were prepared for analytes across each of the acquisition modes. A nonlinear response was observed at high concentrations for some modes, attributed to saturation effects. Two correction methods, one MS1 isotope-correction and one MS2 ion intensity-correction, were applied to address this observation, resulting in an up to twofold increase in dynamic range. By averaging the semi-quantitative results across analyte classes, two parameters, linear dynamic range (LDR) and lower limit of quantification (LLOQ), were determined to evaluate each mode. CONCLUSION: A comparison of the acquisition modes revealed that data-independent acquisition and parallel reaction monitoring methods are most robust for semi-quantitation when considering achievable LDR and LLOQ. IM-enabled modes exhibited sensitivity increases, but a simultaneous reduction in dynamic range required correction methods to recover. These findings will assist users in identifying the optimum acquisition mode for their analyte quantitation needs, supporting a diverse range of applications and providing guidance for future acquisition mode developments.


Subject(s)
Escherichia coli , Peptides , Calibration , Humans , Mass Spectrometry/methods
4.
Anal Chem ; 93(20): 7413-7421, 2021 05 25.
Article in English | MEDLINE | ID: mdl-33984239

ABSTRACT

1-ß-O-Acyl-glucuronides (AGs) are common metabolites of carboxylic acid-containing xenobiotics, including, e.g., many nonsteroidal anti-inflammatory drugs (NSAIDs). They are of concern to regulatory authorities because of the association of these metabolites with the hepatotoxicity that has resulted in drug withdrawal. One factor in assessing the potential risk posed by AGs is the rate of transacylation of the biosynthetic 1-ß-O-acyl form to the 2-, 3-, and 4-O-acyl isomers. While transacylation can be measured using 1H NMR spectroscopy or liquid chromatography-mass spectrometry (LC-MS), the process can be time consuming and involve significant method development. The separation of these positional isomers by ion mobility spectrometry (IMS) has the potential to allow their rapid analysis, but conventional instruments lacked the resolving power to do this. Prediction of the collision cross section (CCS) using a machine learning model suggested that greater IMS resolution might be of use in this area. Cyclic IMS was evaluated for separating mixtures of isomeric AGs of diclofenac and was compared with a conventional ultraperformance liquid chromatography (UPLC)-MS method as a means for studying transacylation kinetics. The resolution of isomeric AGs was not seen using a conventional traveling wave IMS device; however, separation was seen after several passes around a cyclic IMS. The cyclic IMS enabled the degradation of the 1-ß-O-acyl-isomer to be analyzed much more rapidly than by LC-MS. The ability of cyclic IMS to monitor the rate of AG transacylation at different pH values, without the need for a prior chromatographic separation, should allow high-throughput, real-time, monitoring of these types of reactions.


Subject(s)
Glucuronides , Ion Mobility Spectrometry , Diclofenac/analogs & derivatives , Mass Spectrometry
5.
Clin Chem Lab Med ; 58(6): 980-993, 2020 06 25.
Article in English | MEDLINE | ID: mdl-31940282

ABSTRACT

Prostate cancer accounts for around 15% of male deaths in Western Europe and is the second leading cause of cancer death in men after lung cancer. Mounting evidence suggests that prostate cancer deposits exist within a hypoxic environment and this contributes to radio-resistance thus hampering one of the major therapies for this cancer. Recent reports have shown that nitric oxide (NO) donating non-steroidal anti-inflammatory drugs (NSAIDs) reduced tumour hypoxia as well as maintaining a radio-sensitising/therapeutic effect on prostate cancer cells. The aim of this study was to evaluate the impact of hypoxia on the proteome of the prostate and to establish whether NO-NSAID treatment reverted the protein profiles back to their normoxic status. To this end an established hormone insensitive prostate cancer cell line, PC-3, was cultured under hypoxic and normoxic conditions before and following exposure to NO-NSAID in combination with selected other common prostate cancer treatment types. The extracted proteins were analysed by ion mobility-assisted data independent acquisition mass spectrometry (MS), combined with multivariate statistical analyses, to measure hypoxia-induced alterations in the proteome of these cells. The analyses demonstrated that under hypoxic conditions there were well-defined, significantly regulated/differentially expressed proteins primarily involved with structural and binding processes including, for example, TUBB4A, CIRP and PLOD1. Additionally, the exposure of hypoxic cells to NSAID and NO-NSAID agents, resulted in some of these proteins being differentially expressed; for example, both PCNA and HNRNPA1L were down-regulated, corresponding with disruption in the nucleocytoplasmic shuttling process.


Subject(s)
Cell Hypoxia/physiology , Prostatic Neoplasms/metabolism , Proteome/metabolism , Chromatography, Liquid , Down-Regulation , Gene Expression Regulation, Neoplastic , Humans , Male , Mass Spectrometry , PC-3 Cells , Proteome/analysis , Proteome/genetics , Proteomics , Up-Regulation
6.
Mol Cell Proteomics ; 16(3): 438-450, 2017 03.
Article in English | MEDLINE | ID: mdl-28062798

ABSTRACT

The efficient receptor-mediated targeting of soluble lysosomal proteins to lysosomes requires the modification with mannose 6-phosphate (M6P) residues. Although the absence of M6P results in misrouting and hypersecretion of lysosomal enzymes in many cells, normal levels of lysosomal enzymes have been reported in liver of patients lacking the M6P-generating phosphotransferase (PT). The identity of lysosomal proteins depending on M6P has not yet been comprehensively analyzed. In this study we purified lysosomes from liver of PT-defective mice and 67 known soluble lysosomal proteins were identified that illustrated quantitative changes using an ion mobility-assisted data-independent label-free LC-MS approach. After validation of various differentially expressed lysosomal components by Western blotting and enzyme activity assays, the data revealed a small number of lysosomal proteins depending on M6P, including neuraminidase 1, cathepsin F, Npc2, and cathepsin L, whereas the majority reach lysosomes by alternative pathways. These data were compared with findings on cultured hepatocytes and liver sinusoid endothelial cells isolated from the liver of wild-type and PT-defective mice. Our findings show that the relative expression, targeting efficiency and lysosomal localization of lysosomal proteins tested in cultured hepatic cells resemble their proportion in isolated liver lysosomes. Hypersecretion of newly synthesized nonphosphorylated lysosomal proteins suggest that secretion-recapture mechanisms contribute to maintain major lysosomal functions in liver.


Subject(s)
Hydrolases/metabolism , Lysosomes/metabolism , Mannosephosphates/metabolism , Mucolipidoses/enzymology , Proteome/analysis , Animals , Cells, Cultured , Chromatography, Liquid , Disease Models, Animal , Gene Expression Regulation , Liver/metabolism , Mass Spectrometry , Mice , Mucolipidoses/genetics , Phosphotransferases/deficiency
7.
J Proteome Res ; 17(2): 770-779, 2018 02 02.
Article in English | MEDLINE | ID: mdl-28901143

ABSTRACT

A novel data-independent acquisition (DIA) method incorporating a scanning quadrupole in front of a collision cell and orthogonal acceleration time-of-flight mass analyzer is described. The method has been characterized for the qualitative and quantitative label-free proteomic analysis of complex biological samples. The principle of the scanning quadrupole DIA method is discussed, and analytical instrument characteristics, such as the quadrupole transmission width, scan/integration time, and chromatographic separation, have been optimized in relation to sample complexity for a number of different model proteomes of varying complexity and dynamic range including human plasma, cell lines, and bacteria. In addition, the technological merits over existing DIA approaches are described and contrasted. The qualitative and semiquantitative performance of the method is illustrated for the analysis of relatively simple protein digest mixtures and a well-characterized human cell line sample using untargeted and targeted search strategies. Finally, the results from a human cell line were compared against publicly available data that used similar chromatographic conditions but were acquired with DDA technology and alternative mass analyzer systems. Qualitative comparison showed excellent concordance of results with >90% overlap of the detected proteins.


Subject(s)
Blood Proteins/isolation & purification , Escherichia coli/chemistry , Proteome/isolation & purification , Proteomics/methods , Amino Acid Sequence , Chromatography, Liquid/instrumentation , Chromatography, Liquid/methods , Complex Mixtures/chemistry , HeLa Cells , Humans , K562 Cells , Proteolysis , Proteomics/instrumentation , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
8.
J Proteome Res ; 17(2): 780-793, 2018 02 02.
Article in English | MEDLINE | ID: mdl-29251506

ABSTRACT

Calcineurin is a critical cell-signaling protein that orchestrates growth, stress response, virulence, and antifungal drug resistance in several fungal pathogens. Blocking calcineurin signaling increases the efficacy of several currently available antifungals and suppresses drug resistance. We demonstrate the application of a novel scanning quadrupole DIA method for the analysis of changes in the proteins coimmunoprecipitated with calcineurin during therapeutic antifungal drug treatments of the deadly human fungal pathogen Aspergillus fumigatus. Our experimental design afforded an assessment of the precision of the method as demonstrated by peptide- and protein-centric analysis from eight replicates of the study pool QC samples. Two distinct classes of clinically relevant antifungal drugs that are guideline recommended for the treatment of invasive "aspergillosis" caused by Aspergillus fumigatus, the azoles (voriconazole) and the echinocandins (caspofungin and micafungin), which specifically target the fungal plasma membrane and the fungal cell wall, respectively, were chosen to distinguish variations occurring in the proteins coimmunoprecipitated with calcineurin. Novel potential interactors were identified in response to the different drug treatments that are indicative of the possible role for calcineurin in regulating these effectors. Notably, treatment with voriconazole showed increased immunoprecipitation of key proteins involved in membrane ergosterol biosynthesis with calcineurin. In contrast, echinocandin (caspofungin or micafungin) treatments caused increased immunoprecipitation of proteins involved in cell-wall biosynthesis and septation. Furthermore, abundant coimmunoprecipitation of ribosomal proteins with calcineurin occurred exclusively in echinocandins treatment, indicating reprogramming of cellular growth mechanisms during different antifungal drug treatments. While variations in the observed calcineurin immunoprecipitated proteins may also be due to changes in their expression levels under different drug treatments, this study suggests an important role for calcineurin-dependent cellular mechanisms in response to antifungal treatment of A. fumigatus that warrants future studies.


Subject(s)
Aspergillus fumigatus/drug effects , Calcineurin/isolation & purification , Fungal Proteins/isolation & purification , Ribosomal Proteins/isolation & purification , Voriconazole/pharmacology , Antifungal Agents/pharmacology , Aspergillus fumigatus/chemistry , Aspergillus fumigatus/genetics , Aspergillus fumigatus/metabolism , Calcineurin/genetics , Calcineurin/metabolism , Caspofungin , Cell Membrane/chemistry , Cell Membrane/drug effects , Cell Membrane/metabolism , Cell Wall/chemistry , Cell Wall/drug effects , Cell Wall/metabolism , Chromatography, Liquid/methods , Echinocandins/pharmacology , Ergosterol/biosynthesis , Fungal Proteins/genetics , Fungal Proteins/metabolism , Gene Expression , Gene Ontology , Genes, Reporter , Green Fluorescent Proteins/genetics , Green Fluorescent Proteins/metabolism , Immunoprecipitation , Lipopeptides/pharmacology , Micafungin , Molecular Sequence Annotation , Protein Binding , Protein Interaction Mapping , Ribosomal Proteins/genetics , Ribosomal Proteins/metabolism , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
9.
J Proteome Res ; 17(12): 4051-4060, 2018 12 07.
Article in English | MEDLINE | ID: mdl-30270626

ABSTRACT

The 2017 Dagstuhl Seminar on Computational Proteomics provided an opportunity for a broad discussion on the current state and future directions of the generation and use of peptide tandem mass spectrometry spectral libraries. Their use in proteomics is growing slowly, but there are multiple challenges in the field that must be addressed to further increase the adoption of spectral libraries and related techniques. The primary bottlenecks are the paucity of high quality and comprehensive libraries and the general difficulty of adopting spectral library searching into existing workflows. There are several existing spectral library formats, but none captures a satisfactory level of metadata; therefore, a logical next improvement is to design a more advanced, Proteomics Standards Initiative-approved spectral library format that can encode all of the desired metadata. The group discussed a series of metadata requirements organized into three designations of completeness or quality, tentatively dubbed bronze, silver, and gold. The metadata can be organized at four different levels of granularity: at the collection (library) level, at the individual entry (peptide ion) level, at the peak (fragment ion) level, and at the peak annotation level. Strategies for encoding mass modifications in a consistent manner and the requirement for encoding high-quality and commonly seen but as-yet-unidentified spectra were discussed. The group also discussed related topics, including strategies for comparing two spectra, techniques for generating representative spectra for a library, approaches for selection of optimal signature ions for targeted workflows, and issues surrounding the merging of two or more libraries into one. We present here a review of this field and the challenges that the community must address in order to accelerate the adoption of spectral libraries in routine analysis of proteomics datasets.


Subject(s)
Databases, Protein/standards , Peptide Library , Proteomics/methods , Animals , Humans , Tandem Mass Spectrometry/methods , Workflow
10.
Rapid Commun Mass Spectrom ; 31(19): 1599-1606, 2017 Oct 15.
Article in English | MEDLINE | ID: mdl-28703389

ABSTRACT

RATIONALE: A novel data-independent acquisition method is detailed that incorporates a scanning quadrupole in front of an orthogonal acceleration time-of-flight (TOF) mass analyser. This approach is described and the attributes are compared and contrasted to other DIA approaches. METHODS: Specific application of the method to both targeted and untargeted lipidomic identification strategies is discussed, with data from both shotgun and LC separated lipidomics experiments presented. RESULTS: The benefits of the fast quadrupole scanning technique are highlighted, and include improvements in speed and specificity for complex mixtures providing high quality qualitative and quantitative data. CONCLUSIONS: In particular the high specificity afforded by the scanning quadrupole improves qualitative information for lipid identification.


Subject(s)
Chromatography, High Pressure Liquid/methods , Lipids/analysis , Mass Spectrometry/methods , Animals , Cattle , Male , Metabolomics/methods , Mice , Myocardium/chemistry , Testis/chemistry
11.
Proteomics ; 16(15-16): 2206-20, 2016 08.
Article in English | MEDLINE | ID: mdl-27214876

ABSTRACT

The application of unit resolution tandem quadrupole and high-resolution orthogonal acceleration ToF mass spectrometers for the quantitation and translational analysis of proteolytic peptides is described. The MS platforms were contrasted in terms of sensitivity and linear response. Moreover, the selectivity of the platforms was investigated and the effect on quantitative precision studied. Chromatographic LC conditions, including gradient length and configuration, were investigated with respect to speed/throughput, while minimizing isobaric interferences, thereby providing information with regard to practical sample cohort size limitations of LC-MS for large cohort experiments. In addition to these fundamental analytical performance metrics, precision and linear dynamic ranges were also studied. An LC-MS configuration that encompasses the best combination of throughput and analytical accuracy for translational studies was chosen, despite the MS platforms giving similar quantitative performance, and instances were identified where alternative combinations were found to be beneficial. This configuration was utilized to demonstrate that proteolytically digested nondepleted samples from heart failure patients could be classified with good discriminative power using a subset of proteins previously suggested as candidate biomarkers for cardiovascular diseases.


Subject(s)
Mass Spectrometry/methods , Chromatography, Liquid/methods , Peptides/analysis , Peptides/chemistry , Reproducibility of Results , Translational Research, Biomedical
12.
Proteomics ; 16(15-16): 2284-301, 2016 08.
Article in English | MEDLINE | ID: mdl-27296928

ABSTRACT

In proteomics studies, it is generally accepted that depth of coverage and dynamic range is limited in data-directed acquisitions. The serial nature of the method limits both sensitivity and the number of precursor ions that can be sampled. To that end, a number of data-independent acquisition (DIA) strategies have been introduced with these methods, for the most part, immune to the sampling issue; nevertheless, some do have other limitations with respect to sensitivity. The major limitation with DIA approaches is interference, i.e., MS/MS spectra are highly chimeric and often incapable of being identified using conventional database search engines. Utilizing each available dimension of separation prior to ion detection, we present a new multi-mode acquisition (MMA) strategy multiplexing both narrowband and wideband DIA acquisitions in a single analytical workflow. The iterative nature of the MMA workflow limits the adverse effects of interference with minimal loss in sensitivity. Qualitative identification can be performed by selected ion chromatograms or conventional database search strategies.


Subject(s)
Proteomics/methods , Tandem Mass Spectrometry/methods , Software
13.
Mol Cell Proteomics ; 13(12): 3709-15, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25106551

ABSTRACT

One of the limiting factors in determining the sensitivity of tandem mass spectrometry using hybrid quadrupole orthogonal acceleration time-of-flight instruments is the duty cycle of the orthogonal ion injection system. As a consequence, only a fraction of the generated fragment ion beam is collected by the time-of-flight analyzer. Here we describe a method utilizing postfragmentation ion mobility spectrometry of peptide fragment ions in conjunction with mobility time synchronized orthogonal ion injection leading to a substantially improved duty cycle and a concomitant improvement in sensitivity of up to 10-fold for bottom-up proteomic experiments. This enabled the identification of 7500 human proteins within 1 day and 8600 phosphorylation sites within 5 h of LC-MS/MS time. The method also proved powerful for multiplexed quantification experiments using tandem mass tags exemplified by the chemoproteomic interaction analysis of histone deacetylases with Trichostatin A.


Subject(s)
Histone Deacetylases/analysis , Peptide Fragments/analysis , Phosphoproteins/analysis , Proteomics/instrumentation , Tandem Mass Spectrometry/instrumentation , Flow Injection Analysis , HeLa Cells , Histone Deacetylase Inhibitors/chemistry , Humans , Hydroxamic Acids/chemistry , Ions , Phosphorylation , Proteomics/methods , Sensitivity and Specificity , Tandem Mass Spectrometry/methods , Time Factors , Trypsin/chemistry
14.
J Proteome Res ; 13(8): 3554-61, 2014 Aug 01.
Article in English | MEDLINE | ID: mdl-24946097

ABSTRACT

Diagnosis of Parkinson's disease, the second most common neurodegenerative disease, is based on the appearance of motor symptoms. A panel of protein biomarkers in the T-lymphocyte proteome was previously proposed as a Parkinson's disease signature. Here, we designed an LC-MS based method to quantitatively evaluate this protein signature by multiple reaction monitoring (MRM) in T-lymphocytes and peripheral blood mononuclear cells from a new cohort of nine patients with Parkinson's disease and nine unaffected subjects. Patients were classified using the discriminant function obtained from two-dimensional electrophoresis and protein amounts measured by MRM, thus assigning seven controls out of nine as true negatives and nine patients out of nine as true positives. A good discriminant power was obtained by selecting a subset of peptides from the protein signature, with an area under the receiver operating characteristic curve of 0.877. A similar result is achieved by evaluating all peptides of a selected panel of proteins (gelsolin, moesin, septin-6, twinfilin-2, lymphocyte-specific protein 1, vimentin, transaldolase), with an area under the curve of 0.840. Conversely, the signature was not able to classify the enrolled subjects when evaluated in whole mononuclear cells. Overall, this report shows the portability of the proposed method to a large-scale clinical validation study.


Subject(s)
Biomarkers/metabolism , Cytoskeletal Proteins/metabolism , Parkinson Disease/diagnosis , Parkinson Disease/immunology , T-Lymphocytes/metabolism , Amino Acid Sequence , Area Under Curve , Discriminant Analysis , Electrophoresis, Gel, Two-Dimensional , Humans , Molecular Sequence Data , Parkinson Disease/metabolism , Peptides/genetics , Peptides/metabolism
15.
Biochem Biophys Res Commun ; 452(1): 21-6, 2014 Sep 12.
Article in English | MEDLINE | ID: mdl-25150443

ABSTRACT

Idiopathic nephrotic syndrome (INS) is caused by renal diseases that increase the permeability of the glomerular filtration barrier without evidence of a specific systemic cause. The aim of the present work was to reveal inherent molecular features of INS in children using combined urinary proteomics and metabolomics profiling. In this study, label-free mass spectrometric analysis of urinary proteins and small molecule metabolites was carried out in 12 patients with INS versus 12 sex- and age-matched control subjects with normal renal function. Integration and biological interpretation of obtained results were carried out by Ingenuity IPA software. Validation of obtained proteomics data was carried out by Western blot method. Proteomics data have been deposited to the ProteomeXchange Consortium with the data set identifier PXD000765. This study indicates for the first time that paediatric INS is associated with up-regulation of afamin, hydroxyphenylacetate and uridine, and concomitant down-regulation in glutamine and phenylalanine levels, and many of these molecular species were previously shown to be involved in oxidative stress. Further studies in larger patient population are underway to investigate the role of oxidative stress in renal injury in paediatric INS.


Subject(s)
Kidney Diseases/metabolism , Mass Spectrometry/methods , Proteinuria/urine , Blotting, Western , Child , Female , Humans , Kidney Diseases/urine , Male , Metabolomics
16.
J Chromatogr A ; 1714: 464537, 2024 Jan 11.
Article in English | MEDLINE | ID: mdl-38157664

ABSTRACT

The use of HILIC-based separations for the analysis of polar metabolites in metabolic phenotyping studies is well established. Here, we demonstrate the increased coverage of the polar metabolome obtained by travelling wave (TW) ion mobility (IM) instruments combined with HILIC and mass spectrometry (MS) for metabotyping rat and mouse urine samples. Profiling was performed using either a linear TW IM-MS based instrument with a path length of 40 cm or an instrument with a cyclic travelling wave analyser (cIM) with a path length of 95 cm. Due to the added resolution afforded by using both the linear and cyclic IM geometries with MS detection (IM-MS) significant increases in feature count (m/z-tR pairs) were generally obtained compared to HILIC-MS alone. In addition, the use of both linear and cyclic IM-MS improved the quality of the mass spectra obtained as a result of the separation of co-eluting analytes. As would be expected from the increased path length of the cyclic IM-MS instrument compared to the linear device, the largest gains in feature detection were obtained for the HILIC-cIM-MS combination. By increasing the resolution of coeluting components, the cyclic IM-MS instrumentation also provided the largest improvement in the quality of the mass spectral data obtained. When applied to mouse urines obtained from both control and gefitinib-dosed mice, time-related changes were detected in those obtained from the treated animals that were not seen in the controls. Polar metabolites affected by drug administration included, but were not limited to, hypoxanthine, 1,3-dimethyluracil and acetylcarnitine. The changes seen in the relative concentrations of these endogenous metabolites appeared to be related to drug concentrations in the plasma and urine suggesting a pharmacometabodynamic link.


Subject(s)
Body Fluids , Metabolome , Rats , Mice , Animals , Mass Spectrometry/methods , Chromatography, High Pressure Liquid/methods , Hydrophobic and Hydrophilic Interactions , Metabolomics/methods
17.
Talanta ; 274: 125970, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38621320

ABSTRACT

The use of collision cross section (CCS) values derived from ion mobility studies is proving to be an increasingly important tool in the characterization and identification of molecules detected in complex mixtures. Here, a novel machine learning (ML) based method for predicting CCS integrating both molecular modeling (MM) and ML methodologies has been devised and shown to be able to accurately predict CCS values for singly charged small molecular weight molecules from a broad range of chemical classes. The model performed favorably compared to existing models, improving compound identifications for isobaric analytes in terms of ranking and assigning identification probability values to the annotation. Furthermore, charge localization was seen to be correlated with CCS prediction accuracy and with gas-phase proton affinity demonstrating the potential to provide a proxy for prediction error based on chemical structural properties. The presented approach and findings represent a further step towards accurate prediction and application of computationally generated CCS values.

18.
Rapid Commun Mass Spectrom ; 27(21): 2383-90, 2013 Nov 15.
Article in English | MEDLINE | ID: mdl-24097394

ABSTRACT

RATIONALE: Electron transfer dissociation (ETD) within ion trapping mass spectrometers has proven to be a useful tool for the characterisation of post-translational modifications. In this study, we describe the implementation of ETD upon a modified quadrupole time-of-flight (Q-ToF) system and methods for the analysis of glycoproteins. METHODS: Liquid chromatography electrospray ionisation mass spectrometry (LC/ESI-MS) was performed using a hybrid quadrupole/ion mobility/oa-ToF mass spectrometer equipped with ETD functionality. 1,4-Dicyanobenzene reagent anions necessary for the ETD reaction were generated from a glow discharge region located within the ESI source block. ETD reactions occurred in the stacked ring travelling wave ion guide (located after the quadrupole mass filter and prior to the oa-ToF mass analyser). LC/ETD was performed upon 'super-charged' tryptic glycopeptide ions produced from the recombinant monoclonal antibody trastuzumab. LC/ETD was also performed on ions from the smaller glycopeptides obtained from erythropoietin. RESULTS: ETD performed upon the quadruply 'super-charged' N-linked glycopeptide ions of trastuzumab and the triply charged O-linked glycopeptide ions of erythropoietin provided both glycosylation site assignments and full sequence information, respectively. Tandem mass (MS/MS) spectra employing collision-induced dissociation (CID) were dominated by oxonium product ions hampering full peptide sequence characterisation. CONCLUSIONS: LC/ETD on the Q-ToF system proved effective at characterising a number of different N-linked glyco-forms of the tryptic peptide, EEQYNSTYR, from trastuzumab as well as glyco-forms from the O-linked tryptic peptide, EASIPPDAASAAPLR, from erythropoietin. The data demonstrates that the glycopeptide site heterogeneity of trastuzumab and erythropoietin can be accurately characterised. In addition, the post-column mixing of the super-charging reagent, m-NBA, is an effective method to increase the precursor ion charge state and to improve ETD reaction efficiency.


Subject(s)
Antibodies, Monoclonal, Humanized/chemistry , Glycoproteins/chemistry , Spectrometry, Mass, Electrospray Ionization/methods , Amino Acid Sequence , Chromatography, Liquid/instrumentation , Chromatography, Liquid/methods , Electrons , Equipment Design , Glycopeptides/chemistry , Molecular Sequence Data , Spectrometry, Mass, Electrospray Ionization/instrumentation , Trastuzumab
19.
Anal Bioanal Chem ; 404(4): 1127-39, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22811061

ABSTRACT

To accurately determine the quantitative change of peptides and proteins in complex proteomics samples requires knowledge of how well each ion has been measured. The precision of each ions' calculated area is predicated on how uniquely it occupies its own space in m/z and elution time. Given an initial assumption that prior to the addition of the "heavy" label, all other ion detections are unique, which is arguably untrue, an initial attempt at quantifying the pervasiveness of ion interference events in a representative binary SILAC experiment was made by comparing the centered m/z and retention time of the ion detections from the "light" variant to its "heavy" companion. Ion interference rates were determined for LC-MS data acquired at mass resolving powers of 20 and 40 K with and without ion mobility separation activated. An ion interference event was recorded, if present in the companion dataset was an ion within ± its Δ mass at half-height, ±15 s of its apex retention time and if utilized by ±1 drift bin. Data are presented illustrating a definitive decrease in the frequency of ion interference events with each additional increase in selectivity of the analytical workflow. Regardless of whether the quantitative experiment is a composite of labeled samples or label free, how well each ion is measured can be determined given knowledge of the instruments mass resolving power across the entire m/z scale and the ion detection algorithm reporting both the centered m/z and Δ mass at half-height for each detected ion. Given these measurements, an effective resolution can be calculated and compared with the expected instrument performance value providing a purity score for the calculated ions' area based on mass resolution. Similarly, chromatographic and drift purity scores can be calculated. In these instances, the error associated to an ions' calculated peak area is estimated by examining the variation in each measured width to that of their respective experimental median. Detail will be disclosed as to how a final ion purity score was established, providing a first measure of how accurately each ions' area was determined as well as how precise the calculated quantitative change between labeled or unlabelled pairs were determined. Presented is how common ion interference events are in quantitative proteomics LC-MS experiments and how ion purity filters can be utilized to overcome and address them, providing ultimately more accurate and precise quantification results across a wider dynamic range.


Subject(s)
Mass Spectrometry/standards , Proteins/chemistry , Proteomics/standards , Algorithms , Caenorhabditis elegans Proteins/chemistry , Cell Line, Tumor , Humans , Mass Spectrometry/methods , Peptides/chemistry , Proteomics/methods , Saccharomyces cerevisiae Proteins/chemistry
20.
JACS Au ; 2(9): 2013-2022, 2022 Sep 26.
Article in English | MEDLINE | ID: mdl-36186554

ABSTRACT

Parkinson's disease (PD) is the second most common neurodegenerative disorder, and identification of robust biomarkers to complement clinical diagnosis will accelerate treatment options. Here, we demonstrate the use of direct infusion of sebum from skin swabs using paper spray ionization coupled with ion mobility mass spectrometry (PS-IM-MS) to determine the regulation of molecular classes of lipids in sebum that are diagnostic of PD. A PS-IM-MS method for sebum samples that takes 3 min per swab was developed and optimized. The method was applied to skin swabs collected from 150 people and elucidates ∼4200 features from each subject, which were independently analyzed. The data included high molecular weight lipids (>600 Da) that differ significantly in the sebum of people with PD. Putative metabolite annotations of several lipid classes, predominantly triglycerides and larger acyl glycerides, were obtained using accurate mass, tandem mass spectrometry, and collision cross section measurements.

SELECTION OF CITATIONS
SEARCH DETAIL