Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 73
Filter
Add more filters

Publication year range
1.
Eur Heart J ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38747561

ABSTRACT

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

2.
Am Heart J ; 269: 108-117, 2024 03.
Article in English | MEDLINE | ID: mdl-38128897

ABSTRACT

Hypertension remains a leading preventable cause of myocardial infarction, stroke, kidney disease, and cardiovascular death worldwide. Despite lifestyle modifications and intensification of medical therapy, suboptimal blood pressure control is common, spurring the development of device-based therapies for hypertension. The US Food and Drug Administration (FDA) assembled the Circulatory System Devices Panel on August 22-23, 2023, to discuss the safety and effectiveness of renal denervation devices manufactured by Recor Medical and Medtronic. After reviewing the ultrasound-based Recor Paradise renal denervation system the day prior, the panel reconvened to discuss the radiofrequency-based Medtronic Symplicity Spyral Renal Denervation System. In this manuscript, we summarize the data presented by the sponsor and FDA and detail the deliberation and discussion during the meeting.


Subject(s)
Cardiovascular System , Hypertension , United States , Humans , United States Food and Drug Administration , Kidney/surgery , Blood Pressure , Sympathectomy , Treatment Outcome , Antihypertensive Agents/therapeutic use
3.
Am Heart J ; 275: 21-34, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38815781

ABSTRACT

Tricuspid regurgitation (TR) is common and associated with significant mortality and morbidity. Because the effectiveness and safety of medical and surgical treatments are limited, there is a significant unmet need for the treatment of this disease. Therefore, there is a growing market for percutaneous devices that offer safer, less invasive, and more effective treatment options in this patient population. On February 13, 2024, the US Food and Drug Administration (FDA) convened a meeting of the Circulatory System Devices Panel to discuss the safety and effectiveness of the TriClip Transcatheter Valve Repair System (Abbott, Santa Clara, CA, USA). Several important points were discussed, including newly published data from the TRILUMINATE Pivotal study, the use of patient-oriented outcomes for device approval, and a discussion about training requirements and rollout plans when approving a breakthrough device. In this manuscript, we summarize the data presented by the sponsor and FDA and describe the deliberations and discussions during the meeting.


Subject(s)
Cardiac Catheterization , Device Approval , Tricuspid Valve Insufficiency , Tricuspid Valve , United States Food and Drug Administration , Humans , Advisory Committees , Cardiac Catheterization/methods , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/methods , Prosthesis Design , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/surgery , United States
4.
Am Heart J ; 271: 112-122, 2024 05.
Article in English | MEDLINE | ID: mdl-38395293

ABSTRACT

BACKGROUND: To date, there has been no independent core lab angiographic analysis of patients with COVID-19 and STEMI. The study characterized the angiographic parameters of patients with COVID-19 and STEMI. METHODS: Angiograms of patients with COVID-19 and STEMI from the North American COVID-19 Myocardial Infarction (NACMI) Registry were sent to a Core Laboratory in Vancouver, Canada. Culprit lesion(s), Thrombolysis In Myocardial Infarction (TIMI) flow, Thrombus Grade Burden (TGB), and percutaneous coronary intervention (PCI) outcome were assessed. RESULTS: From 234 patients, 74% had one culprit lesion, 14% had multiple culprits and 12% had no culprit identified. Multivessel thrombotic disease and multivessel CAD were found in 27% and 53% of patients, respectively. Stent thrombosis accounted for 12% of the presentations and occurred in 55% of patients with previous coronary stents. Of the 182 who underwent PCI, 60 (33%) had unsuccessful PCI due to post-PCI TIMI flow <3 (43/60), residual high thrombus burden (41/60) and/or thrombus related complications (27/60). In-hospital mortality for successful, partially successful, and unsuccessful PCI was 14%, 13%, and 27%, respectively. Unsuccessful PCI was associated with increased risk of in-hospital mortality (risk ratio [RR] 1.96; 95% CI: 1.05-3.66, P = .03); in the adjusted model this estimate was attenuated (RR: 1.24; 95% CI: 0.65-2.34, P = .51). CONCLUSION: In patients with COVID-19 and STEMI, thrombus burden was pervasive with notable rates of multivessel thrombotic disease and stent thrombosis. Post-PCI, persistent thrombus and sub-optimal TIMI 3 flow rates led to one-third of the PCI's being unsuccessful, which decreased over time but remained an important predictor of in-hospital mortality.


Subject(s)
COVID-19 , Coronary Angiography , Percutaneous Coronary Intervention , Registries , ST Elevation Myocardial Infarction , Humans , ST Elevation Myocardial Infarction/therapy , ST Elevation Myocardial Infarction/diagnostic imaging , COVID-19/complications , COVID-19/therapy , Male , Female , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/statistics & numerical data , Middle Aged , Aged , Hospital Mortality , SARS-CoV-2 , Coronary Thrombosis/diagnostic imaging , Canada/epidemiology
5.
Catheter Cardiovasc Interv ; 104(2): 247-251, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38860616

ABSTRACT

In the absence of standardized management guidelines, coronary artery aneurysms (CAAs) present therapeutic challenges. Percutaneous coronary intervention (PCI) is rarely explored, especially in giant aneurysms with persistent angina, where surgery might be presumed as a preferred option. We describe the technical aspects and feasibility of PCI using Gore Viabahn expanded polytetrafluoroethylene (ePTFE)-covered nitinol self-expanding stents in a 66-year-old woman with a complex medical history and an enlarging, symptomatic right coronary artery aneurysm. The case was complicated by endoleak after the first stent, but intravascular ultrasound guidance enabled the precise deployment of additional stents, resulting in the successful exclusion of the aneurysm. This case demonstrates steps to successful CAA PCI with Gore Viabahn ePTFE-covered nitinol self-expanding stents and emphasizes that in unsuitable surgical candidates, PCI might be a potential alternative for symptomatic CAAs.


Subject(s)
Alloys , Coronary Aneurysm , Prosthesis Design , Ultrasonography, Interventional , Humans , Coronary Aneurysm/diagnostic imaging , Coronary Aneurysm/surgery , Coronary Aneurysm/therapy , Aged , Female , Treatment Outcome , Self Expandable Metallic Stents , Coronary Angiography , Polytetrafluoroethylene , Percutaneous Coronary Intervention/instrumentation , Stents , Angioplasty, Balloon, Coronary/instrumentation
6.
Catheter Cardiovasc Interv ; 104(1): 34-43, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38713867

ABSTRACT

Hypertension continues to be a prominent, avoidable factor contributing to major vascular issues on a global scale. Even with lifestyle adjustments and more aggressive medical treatments, maintaining optimal blood pressure levels remains challenging. This challenge has driven the emergence of device-oriented approaches to address hypertension. To assess the safety and efficacy of the Recor Paradise Ultrasound Renal Denervation System, the Circulatory System Devices Panel was convened by the US Food and Drug Administration (FDA). This manuscript provides a condensed overview of the information put forth by the sponsor and the FDA, along with an account of the considerations and conversations that took place during the meeting.


Subject(s)
Blood Pressure , Device Approval , Hypertension , Renal Artery , Sympathectomy , United States Food and Drug Administration , Humans , United States , Sympathectomy/adverse effects , Sympathectomy/instrumentation , Hypertension/physiopathology , Hypertension/surgery , Renal Artery/innervation , Renal Artery/diagnostic imaging , Treatment Outcome , Kidney/blood supply , Advisory Committees , Equipment Design , Risk Factors
7.
Catheter Cardiovasc Interv ; 103(6): 917-923, 2024 May.
Article in English | MEDLINE | ID: mdl-38605682

ABSTRACT

The advent of excimer laser coronary atherectomy (ELCA) nearly four decades ago heralded a novel way to treat complex lesions, both coronary and peripheral, which were previously untraversable and thus untreatable. These complex lesions include heavily calcified lesions, ostial lesions, bifurcation lesions, chronic total occlusions, in-stent restenosis (including stent underexpansion), and degenerative saphenous vein grafts. We discuss the technology of ELCA, its indications, applications, and complications, and suggest the "MAXCon ELCA" technique for better outcomes without increased risk. Lastly, we present a case of MAXCon ELCA effectively treating a complex lesion.


Subject(s)
Atherectomy, Coronary , Coronary Angiography , Coronary Artery Disease , Lasers, Excimer , Humans , Contrast Media , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Lasers, Excimer/therapeutic use , Saline Solution/administration & dosage , Treatment Outcome
8.
Catheter Cardiovasc Interv ; 103(4): 523-531, 2024 03.
Article in English | MEDLINE | ID: mdl-38440914

ABSTRACT

BACKGROUND: Percutaneous coronary intervention (PCI) is considered less safe in patients with reduced ejection fraction (EF), an impression based on older data. Whether the safety and durability of contemporary PCI are different in patients with reduced EF compared with normal EF patients is unknown. METHODS: Patients from the BIOFLOW II, IV and V clinical trials were grouped as normal EF (≥50%) and reduced EF (30%-50%). Using multivariable logistic regression and cox proportional hazards regression, we determined relations of EF category with procedural safety (a composite of cardiac death, myocardial infarction, stroke and urgent coronary artery bypass grafting within 30 days of PCI) and target lesion failure (TLF; comprising cardiac death, target vessel myocardial infarction, target vessel revascularization within 1 year of PCI) respectively. In sensitivity analyses, we regrouped patients into EF < 45% and ≥55% and repeated the aforementioned analyses. RESULTS: In 1685 patients with normal EF (mean age 65 years; 27% women; mean EF 61%) and 259 with low EF (mean age 64 years; 17% women; mean EF 41%), 101 safety and 148 TLF events occurred. Compared with patients in the normal EF group, those with reduced EF had neither a statistically significant higher proportion of safety events, nor a higher multivariable-adjusted risk for such events. Similarly, patients with reduced EF and normal EF did not differ in terms of TLF event proportions or multivariable-adjusted risk for TLF. The results were similar in sensitivity analyses with EF groups redefined to create a 10% between-group EF separation. CONCLUSION: PCI safety and durability outcomes are similar in patients with mild-moderately reduced EF and normal EF.


Subject(s)
Myocardial Infarction , Percutaneous Coronary Intervention , Ventricular Dysfunction, Left , Humans , Female , Aged , Middle Aged , Male , Percutaneous Coronary Intervention/adverse effects , Treatment Outcome , Myocardial Infarction/etiology , Coronary Artery Bypass/adverse effects , Ventricular Dysfunction, Left/etiology , Death
9.
Catheter Cardiovasc Interv ; 103(5): 691-694, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38440925

ABSTRACT

BACKGROUND: With advances in technology and technique, the expectations are that patients undergoing procedures in the cardiac catheterization laboratory will not need to return for a repeat procedure within the same day. OBJECTIVES: Report why subjects undergoing cardiac procedures return urgently to the catheterization laboratory for a repeat procedure during the same day. METHODS: We retrospectively reviewed patients who were brought back to the cardiac catheterization laboratory within the same day for a repeat procedure. The reasons for index and repeat procedure were identified. Patients who were transferred from an outside center after an initial procedure at other centers were excluded. RESULTS: Between November 2013 and January 2022, 55,942 catheterization procedures were performed at our institution, of which 140 entries were included in our analysis. Common reasons for the index procedure were diagnostic angiography (35.0%), percutaneous coronary intervention (PCI, 29.2%), and transcatheter aortic valve replacement (15.0%). The most common reason for bringing these patients back to the cardiac catheterization laboratory within the same day was vascular complications (24.2%), followed by repeat PCI (20.7%), need for hemodynamic support (15.0%), heart team discussion and PCI (10%), and pacemaker implantation (10%). Acute limb ischemia was the most commonly identified vascular complication (7.1%), followed by pseudoaneurysm (5%). CONCLUSION: Our study demonstrates that a very small number of patients underwent repeat procedures within the same day. Special attention should be paid to vascular access and closure and assessment of recurrent chest pain postprocedure, as these are the main reasons for same-day repeat procedures.


Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Percutaneous Coronary Intervention , Humans , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Retrospective Studies , Treatment Outcome , Angiography , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods
10.
Catheter Cardiovasc Interv ; 103(5): 703-709, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38520176

ABSTRACT

BACKGROUND: Full adoption of coronary microvascular dysfunction (CMD) assessment faces challenges due to its invasive nature and concerns about prolonged procedure time and increased contrast and/or radiation exposure. We compared procedural aspects of CMD invasive assessment to diagnostic left heart catheterization (DLHC) in patients with chest pain who were not found to have obstructive coronary artery disease. METHODS: A total of 227 patients in the Coronary Microvascular Disease Registry were compared to 1592 patients who underwent DLHC from August 2021 to November 2023. The two cohorts were compared using propensity-score matching; primary outcomes were fluoroscopy time and total contrast use. RESULTS: The participants' mean age was 64.1 ± 12.6 years. CMD-assessed patients were more likely to be female (66.5% vs. 45.2%, p < 0.001) and have hypertension (80.2% vs. 44.5%, p < 0.001), history of stroke (11.9% vs. 6.3%, p = 0.002), and history of myocardial infarction (20.3% vs. 7.7%, p < 0.001). CMD assessment was safe, without any reported adverse outcomes. A propensity-matched analysis showed that patients who underwent CMD assessment had slightly higher median contrast exposure (50 vs. 40 mL, p < 0.001), and slightly longer fluoroscopy time (6.9 vs. 4.7 min, p < 0.001). However, there was no difference in radiation dose (209.3 vs. 219 mGy, p = 0.58) and overall procedure time (31 vs. 29 min, p = 0.37). CONCLUSION: Compared to DLHC, CMD assessment is safe and requires only slightly additional contrast use (10 mL) and slightly longer fluoroscopy time (2 min) without clinical implications. These findings emphasize the favorable safety and feasibility of invasive CMD assessment.


Subject(s)
Coronary Artery Disease , Microvascular Angina , Myocardial Infarction , Myocardial Ischemia , Humans , Female , Middle Aged , Aged , Male , Treatment Outcome , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Microvascular Angina/diagnosis , Coronary Circulation , Microcirculation , Coronary Vessels/diagnostic imaging
11.
Catheter Cardiovasc Interv ; 104(1): 125-133, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38769727

ABSTRACT

BACKGROUND: The Evolut self-expanding valve (SEV) systems (Medtronic), were designed to accommodate varying valve sizes and reduce paravalvular leak (PVL) while maintaining a low delivery profile. These systems have evolved between product generations, alongside valve deployment techniques changing over time. AIMS: This study aimed to examine whether these changes impacted clinical outcomes. METHODS: EPROMPT is a prospective, investigator-initiated, postmarketing registry of consecutive patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) using the Evolut PRO/PRO+ SEV system. A total of 300 patients were divided into three consecutive cohorts of 100 patients according to implantation date (January to October 2018, November 2018 to July 2020, and August 2020 to November 2021). Procedural and clinical outcomes over these time periods were compared. RESULTS: Valve Academic Research Consortium (VARC)-2 device implantation success improved over time (70.0% vs. 78.0% vs. 88.8%, p = 0.01), with a similar trend for VARC-3 device success (94.7% vs. 81.7% vs. 96.8%, p < 0.001). PVL (all degrees) frequency was likewise reduced over time (31.0% vs. 17.0% vs. 19.2%, p = 0.04). Furthermore, a trend was noticed toward shorter procedure times and shorter length of stay. However, postprocedural pacemaker implantation rates did not significantly differ (15.2% vs. 21.1% vs. 14.0%, p = 0.43). CONCLUSION: During a 3-year period, we demonstrated better TAVR outcomes with newer SEV iterations, alongside changes in implantation techniques, which might result in better procedural and clinical outcomes. However, we did not see a significant change in peri-procedural pacemaker rates for SEV.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Female , Male , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Time Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Aged , Treatment Outcome , Aged, 80 and over , Prospective Studies , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Risk Factors , Recovery of Function , Product Surveillance, Postmarketing , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Hemodynamics
12.
Article in English | MEDLINE | ID: mdl-39109463

ABSTRACT

BACKGROUND: In 2019, the US Food and Drug Administration (FDA) approved transcatheter aortic valve replacement (TAVR) for low-risk patients with symptomatic severe tricuspid aortic stenosis. However, bicuspid aortic valve (BAV) patients were included only in single-arm registries of pivotal low-risk TAVR trials, resulting in limited data for this subgroup. METHODS: The LRT (Low Risk TAVR) trial was an investigator-initiated, prospective, multicenter study and the first FDA-approved investigational device exemption trial to evaluate the feasibility of TAVR with balloon-expandable or self-expanding valves in low-risk patients with symptomatic severe BAV stenosis. This analysis reports 2-year follow-up, assessing the primary outcome of all-cause mortality and evaluating clinical outcomes. RESULTS: From 2016 to 2019, a total of 72 low-risk patients diagnosed with symptomatic, severe BAV stenosis underwent TAVR across six centers. Six patients were lost to follow-up. At 2-year follow-up, mortality was 1.5% (1 of 66 patients). Among the remaining 65 patients, four experienced nondisabling strokes (6.2%), while 2 (3.1%) developed infective endocarditis. No new permanent pacemakers were required beyond the 30-day follow-up, and no patients, including those with endocarditis, needed aortic valve re-intervention. At the 2-year echocardiography follow-up (n = 65), 27.8% of BAV patients showed mild aortic regurgitation, with none exhibiting moderate or severe regurgitation. The mean aortic gradient was 12.1 ± 4.1 mmHg, and the mean valve area was 1.7 ± 0.5 cm². CONCLUSION: The 2-year follow-up confirms commendable clinical outcomes of TAVR in patients with bicuspid aortic stenosis, establishing its evident safety.

13.
Cardiovasc Revasc Med ; 65: 75-80, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38565427

ABSTRACT

Transcatheter heart valve (THV) procedures require careful planning and consideration to prevent coronary artery obstruction (CAO), which poses a significant and potentially life-threatening condition, especially in patients undergoing valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR). Despite identifying predictors of CAO and utilization of computed tomography and inputting THV features, a significant uncertainty remains in predicting CAO. The ShortCut™ device (Pi-Cardia, Rehovot, Israel) was purposefully designed to modify the leaflets in patients undergoing TAVR, especially prior to ViV procedures, to overcome the risk for CAO. This review aims to detail the device's objectives, structure, procedural steps, the available clinical data, and future directions for its intended utilization in the structural arena for the prevention of CAO.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Coronary Occlusion , Heart Valve Prosthesis , Prosthesis Design , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Treatment Outcome , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/prevention & control , Coronary Occlusion/etiology , Coronary Occlusion/therapy , Risk Factors , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology
14.
EuroIntervention ; 20(1): 32-44, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38165117

ABSTRACT

Atherosclerosis is a chronic condition characterised by the build-up of plaque in the inner lining of the blood vessels and it is the main underlying cause of cardiovascular disease. The development of atherosclerosis is associated with the accumulation of cholesterol and inflammation. Although effective therapies exist to lower low-density lipoprotein cholesterol (LDL-C) levels, some patients still experience cardiovascular events due to persistent inflammation, known as residual inflammatory risk (RIR). Researchers have conducted laboratory and animal studies to investigate the measurement and targeting of the inflammatory cascade associated with atherosclerosis, which have yielded promising results. In addition to guideline-directed lifestyle modifications and optimal medical therapy focusing on reducing LDL-C levels, pharmacological interventions targeting inflammation may provide further assistance in preventing future cardiac events. This review aims to explain the mechanisms of inflammation in atherosclerosis, identifies potential biomarkers, discusses available therapeutic options and their strengths and limitations, highlights future advancements, and summarises notable clinical studies. Finally, an evaluation and management algorithm for addressing RIR is presented.


Subject(s)
Atherosclerosis , Cardiovascular Diseases , Animals , Humans , Cholesterol, LDL , Inflammation , Cardiovascular Diseases/prevention & control , Cholesterol , Risk Factors
15.
EuroIntervention ; 20(13): e793-e805, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38949240

ABSTRACT

Periprocedural stroke after transcatheter aortic valve implantation (TAVI) remains a significant issue, which is associated with high morbidity, and is increasingly important as intervention shifts to younger and lower-risk populations. Over the last decade of clinical experience with TAVI, the incidence of periprocedural stroke has stayed largely unchanged, although it is prone to underreporting due to variation in ascertainment methods. The aetiology of stroke in TAVI patients is multifactorial, and changing risk profiles, differing study populations, and frequent device iterations have made it difficult to discern consistent risk factors. The objective of this review is to analyse and clarify the contemporary published literature on the epidemiology and mechanisms of neurological events in TAVI patients and evaluate potential preventive measures. This summary aims to improve patient risk assessment and refine case selection for cerebral embolic protection devices, while also providing a foundation for designing future trials focused on stroke prevention.


Subject(s)
Aortic Valve Stenosis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Risk Factors , Stroke/etiology , Stroke/prevention & control , Aortic Valve Stenosis/surgery , Risk Assessment , Aortic Valve/surgery , Incidence , Treatment Outcome , Embolic Protection Devices
16.
Article in English | MEDLINE | ID: mdl-38845281

ABSTRACT

Since the advent of coronary stents, two of the most common long-term complications after percutaneous coronary intervention (PCI) are in-stent restenosis (ISR) and stent thrombosis (ST). Although the rates of ST have been nearly abolished and ISR rates have declined with the current gold-standard second-generation drug-eluting stents (DES), late ISR of DES remains a valid concern in the field of interventional cardiology. The drug-coated balloon (DCB) is a non-stent technology that relies on the concept of targeted homogeneous drug delivery from an inflated balloon to restore luminal vascularity, treat atherosclerosis, and overcome some limitations of PCI, including ISR and prolonged dual antiplatelet therapy to prevent ST by leaving nothing behind. Most clinical evidence on coronary DCBs predominantly comes from small, randomized data and registries using paclitaxel DCBs for ISR and de novo lesions in the coronary space. Since 2014, outside the United States, DCBs have been approved for the treatment of ISR, with a class I recommendation by the European Society of Cardiology. The Food and Drug Administration very recently approved the Agent DCB to treat ISR in patients with coronary artery disease in the US. Additionally, recent randomized clinical data also showed DCB's safety and efficacy for the treatment of de novo small-vessel disease and high-bleeding-risk patients, while their role for other clinical situations including acute coronary syndrome, large-vessel disease, bifurcation lesions, and long-diffuse distal lesions is currently under investigation. Herein, we review the evidence-based role of DCBs in the treatment of coronary lesions and offer future perspectives.

17.
Article in English | MEDLINE | ID: mdl-38677895

ABSTRACT

BACKGROUND: Radial artery access has been used for left heart catheterization (LHC) and percutaneous coronary intervention (PCI) for over 30 years. This method has gained popularity among operators due to superficial vessel anatomy, allowing for easy accessibility and compressibility, resulting in effective hemostasis. METHODS: We conducted a retrospective analysis of patients who underwent PCI due to ST-elevation myocardial infarction (STEMI), non-ST-elevation acute coronary syndrome (NSTE-ACS), and chest pain (stable angina) from November 2013 to February 2023. RESULTS: We analyzed validated registries and found 7714 PCIs. Of these, 1230 were STEMI patients, 5585 were NSTE-ACS patients, and 899 were stable angina patients, forming the basis of our final analysis. In STEMI patients, there was a trend toward a higher rate of ventriculography with femoral access compared to radial access (53.4 % vs. 47.5 %, p = 0.06), which was also observed in NSTE-ACS patients (34.2 % vs. 31.8 %, p = 0.07). The use of central venous access was more common with femoral access in all three diagnoses, with significantly higher rates seen in STEMI patients (36.2 % vs. 7.6 %, p < 0.001), NSTE-ACS patients (19.3 % vs. 2.8 %, p < 0.001), and chest pain patients (26.4 % vs. 2.7 %, p < 0.001). CONCLUSIONS: The analysis revealed that operators may perform fewer ventriculography and RHC procedures when using radial access as compared to femoral access. While there is discrepancy in performing left ventriculography and RHC when using a radial artery, it is essential to emphasize that routinely performing ventriculography and hemodynamic assessment has not proven to impact outcomes, despite their contributions to proper decision-making and treatment.

18.
Article in English | MEDLINE | ID: mdl-38724408

ABSTRACT

BACKGROUND: Coronary microvascular dysfunction (CMD) is an etiology for angina with non-obstructive coronary disease. However, the initial adoption of CMD assessment, whether planned or conducted ad hoc, is limited. We characterize planned and ad hoc CMD assessments and highlight evolving trends of a CMD referral center. METHODS: We analyzed outpatient data from the Coronary Microvascular Disease Registry from 2021 to 2023. Patients were categorized into planned or ad hoc CMD assessment groups, and baseline characteristics, hospital stay, medications, and physiological measurements were compared. Secondary analysis evaluated a CMD referral center's evolution. RESULTS: Of 101 included outpatients, 67.3 % underwent ad hoc procedures and 32.7 % planned procedures. Average age was 63.1 ± 10.1 years. The planned procedure group was 87.9 % female, and the ad hoc procedure group was 51.5 % female. There were no significant differences in index of microvascular resistance or coronary flow reserve between groups. Hospital stay duration was <1 day for both groups, and neither reported complications. Ad hoc patients were more frequently prescribed aspirin before (64.7 % vs. 36.4 %, p = 0.007) and after the procedure (66.2 % vs. 39.4 %, p = 0.01). CMD rates were higher for planned procedures (30.3 % vs. 10.3 %, p = 0.01). We observed that CMD referral centers have more planned procedures and a higher rate of positive results over time. CONCLUSION: CMD referral centers' planned procedures, and subsequent positive cases, increased over time. This emphasizes the importance of planned procedures, appropriate patient selection, and increased awareness of CMD among healthcare providers. CLINICAL TRIAL REGISTRATION: Coronary Microvascular Disease (CMD) Registry, NCT05960474, https://clinicaltrials.gov/study/NCT05960474.

19.
Article in English | MEDLINE | ID: mdl-38797580

ABSTRACT

BACKGROUND: Outflow graft obstruction (OGO) is an uncommon yet life-threatening complication in patients with left ventricular assist devices (LVADs). In this retrospective, single-center case series, we identify the baseline demographics and presenting features of patients who develop LVAD OGO and the procedural details and outcomes surrounding percutaneous endovascular intervention (PEI). METHODS: We conducted a retrospective review of patients with LVADs at our institution between January 2010 and February 2023 who developed OGO and were treated with PEI. Details of the PEI including procedure time, fluoroscopy time, contrast use, stent size, number of stents, change in gradient, and change in flow after intervention were collected. RESULTS: A total of 12 patients who had 14 cases of OGO were identified from January 2010 to February 2023. The average age at presentation was 64.78 years. Nine of the 14 cases occurred in male patients. Eleven of the 14 cases occurred with Heartware devices (2 recurrences), 2 in Heartmate 2 and 1 in Heartmate 3. Notable procedural details include a mean procedure time of 90.86 min and mean contrast use of 162.5 mL. The initial gradient across the OGO was reduced by an average of 72 %, to a mean post-PEI of 11.57 mmHg. The average number of stents to achieve this gradient was around 2.08, with the most common stent diameter being 10 mm. Thirty-day mortality after PEI was 7 % (1/14) in this high-risk patient population. CONCLUSION: In our single-center experience, PEI can be a safe and effective treatment for LVAD OGO.

20.
Article in English | MEDLINE | ID: mdl-38719633

ABSTRACT

BACKGROUND: High-sensitivity troponin (hsTnI) is correlated with cardiac mortality; however, studies on the relationship of markedly elevated hsTnI with in-hospital mortality after cardiac surgery are sparse. Therefore, we aimed to define this relationship in order to help guide in-hospital, acute management of post-surgical patients. METHODS: We retrospectively analyzed all cardiac surgeries completed at our institution between January 2020 and June 2022 in which a peak hsTnI was noted to be >35× upper limit of normal (ULN = 34 ng/L). The primary outcome was in-hospital death. Subgroup analysis was performed to assess differences between coronary artery bypass grafting (CABG) and other cardiac surgeries. RESULTS: A total of 1382 cases met inclusion criteria. The patients' mean age was 64.8 years and 68.2 % were male. Median peak hsTnI after surgery was 4202 ng/L (interquartile ratio: 2427-7654). Univariate analysis of troponin level with mortality found that for every 1000 ng/L increase in hsTnI, odds of in-hospital death increased by 3.8 % (odds ratio [OR]: 1.038; 95 % confidence interval [CI] 1.027-1.050; p < 0.0001). In a multivariate model, troponin (OR 1.02; 95 % CI 1.01-1.04; p = 0.004) maintained a significant association with in-hospital death. CABG was associated with a lower risk of in-hospital death for any given hsTnI level up to 60,000 ng/L compared to other cardiac surgeries. CONCLUSION: Increasing hsTnI level is associated with increasing probability of in-hospital mortality and, therefore, serves as an additional, objective measure of risk to help guide in-hospital clinical management.

SELECTION OF CITATIONS
SEARCH DETAIL