Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Prostate ; 82(2): 227-234, 2022 02.
Article in English | MEDLINE | ID: mdl-34734428

ABSTRACT

BACKGROUND: Magnetic resonance imaging (MRI)-targeted prostate biopsy is a routinely used diagnostic tool for prostate cancer (PCa) detection. However, a clear superiority of the optimal approach for software-based MRI processing during biopsy procedures is still unanswered. To investigate the impact of robotic approach and software-based image processing (rigid vs. elastic) during MRI/transrectal ultrasound (TRUS) fusion prostate biopsy (FBx) on overall and clinically significant (cs) PCa detection. METHODS: The study relied on the instructional retrospective biopsy data collected data between September 2013 and August 2017. Overall, 241 men with at least one suspicious lesion (PI-RADS ≥ 3) on multiparametric MRI underwent FBx. The study protocol contains a systematic 12-core sextant biopsy plus 2 cores per targeted lesion. One experienced urologist performed 1048 targeted biopsy cores; 467 (45%) cores were obtained using rigid processing, while the remaining 581 (55%) cores relied on elastic image processing. CsPCa was defined as International Society of Urological Pathology (ISUP) grade ≥ 2. The effect of rigid versus elastic FBx on overall and csPCa detection rates was determined. Propensity score weighting and multivariable regression models were used to account for potential biases inherent to the retrospective study design. RESULTS: In multivariable regression analyses, age, prostate-specific antigen (PSA), and PIRADS ≥ 3 lesion were related to higher odds of finding csPCa. Elastic software-based image processing was independently associated with a higher overall PCa (odds ratio [OR] = 3.6 [2.2-6.1], p < 0.001) and csPCa (OR = 4.8 [2.6-8.8], p < 0.001) detection, respectively. CONCLUSIONS: Contrary to existing literature, our results suggest that the robotic-driven software registration with elastic fusion might have a substantial effect on PCa detection.


Subject(s)
Early Detection of Cancer , Magnetic Resonance Imaging/methods , Prostate/pathology , Prostatic Neoplasms , Software , Ultrasonography, Interventional/methods , Comparative Effectiveness Research , Early Detection of Cancer/methods , Early Detection of Cancer/standards , Early Detection of Cancer/statistics & numerical data , Elastic Modulus , Humans , Image-Guided Biopsy/methods , Male , Middle Aged , Propensity Score , Prostate-Specific Antigen/analysis , Prostatic Neoplasms/blood , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/pathology , Software/classification , Software/standards
2.
Urol Int ; 105(5-6): 446-452, 2021.
Article in English | MEDLINE | ID: mdl-33498059

ABSTRACT

INTRODUCTION: The risk of occult prostate carcinoma (PCa) after negative multiparametric MRI (mpMRI)-transrectal fusion biopsy (F-Bx) is unknown. To determine the false-negative predictive value, we examined PCa detection after prior negative F-Bx. METHODS: Between December 2012 and November 2016, 491 patients with suspected PCa and suspicious mpMRI findings underwent transrectal F-Bx. Patients with benign pathology (n = 191) were eligible for our follow-up (FU) survey. Patient characteristics and clinical parameters were correlated to subsequent findings of newly detected PCa. RESULTS: Complete FU with a median of 31 (interquartile range: 17-39) months was available for 176/191 (92.2%) patients. Of those, 54 men had either surgical interventions on the prostate or re-Bxs. Newly detected PCa was evident in 14/176 (7.95%) patients stratified to ISUP ≤2 in 10 and ≥3 in 4 cases. The comparison of patients with newly detected PCa to those without cancerous findings in FU showed significant differences in prostate-specific antigen (PSA) density (0.16 vs. 0.13 ng/mL2) and prostate volume (45 vs. 67 mL, both p < 0.05). Both factors are significant predictors for newly detected cancer after initial negative F-Bx. CONCLUSION: Only PSA density (>0.13 ng/mL2) and small prostate volume are significant predictors for newly detected PCa after initial negative F-Bx. Despite negative mpMRI/TRUS F-Bx results, patients should be further monitored due to a risk of developing PCa over time. Notwithstanding the limitation of our study that not all patients underwent another Bx, we assume that the false-negative rate is low but existing. Our data represent a real-world scenario.


Subject(s)
Image-Guided Biopsy , Multiparametric Magnetic Resonance Imaging , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Ultrasonography, Interventional , Aged , Humans , Image-Guided Biopsy/methods , Male , Middle Aged , Predictive Value of Tests , Probability , Rectum , Retrospective Studies
3.
Cells Tissues Organs ; 207(1): 1-14, 2019.
Article in English | MEDLINE | ID: mdl-31189166

ABSTRACT

The number of human embryology collections is very limited worldwide. Some of these comprise the Carnegie Collection, Kyoto Collection, and the Blechschmidt Collection. One further embryonic collection is the Hinrichsen Collection of the Ruhr University Bochum, Germany, which also contains very well-preserved embryos/fetuses, along with approximately 16,000 histological sections. The digitization of this collection is indispensable to enable conservation of the collection for the future and to provide a large group of embryologists, researchers, and physicians access to these histological slides. A small selection of these scans is available at the website of the Digital Embryology Consortium [https://-human-embryology.org/wiki/Main_Page].


Subject(s)
Embryo, Mammalian/pathology , Fetus/diagnostic imaging , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Embryo, Mammalian/abnormalities , Female , Fetus/abnormalities , Humans , Infant, Newborn , Male
4.
Kidney Blood Press Res ; 42(6): 1078-1089, 2017.
Article in English | MEDLINE | ID: mdl-29197870

ABSTRACT

BACKGROUND/AIMS: To date, there is no imaging technique to assess tubular function in vivo. Blood oxygen level-dependent magnetic resonance imaging (BOLD MRI) measures tissue oxygenation based on the transverse relaxation rate (R2*). The present study investigates whether BOLD MRI can assess tubular function using a tubule-specific pharmacological maneuver. METHODS: Cross sectional study with 28 participants including 9 subjects with ATN-induced acute kidney injury (AKI), 9 healthy controls, and 10 subjects with nephron sparing tumor resection (NSS) with clamping of the renal artery serving as a model of ischemia/reperfusion (I/R)-induced subclinical ATN (median clamping time 15 min, no significant decrease of eGFR, p=0.14). BOLD MRI was performed before and 5, 7, and 10 min after intravenous administration of 40 mg furosemide. RESULTS: Urinary neutrophil gelatinase-associated lipocalin was significantly higher in ATN-induced AKI and NSS subjects than in healthy controls (p=0.03 and p=0.01, respectively). Before administration of furosemide, absolute medullary R2*, cortical R2*, and medullary/cortical R2* ratio did not significantly differ between ATN-induced AKI vs. healthy controls and between NSS-I/R vs. contralateral healthy kidneys (p>0.05 each). Furosemide led to a significant decrease in the medullary and cortical R2* of healthy subjects and NSS contralateral kidneys (p<0.05 each), whereas there was no significant change of R2* in ATN-induced AKI and the NSS-I/R kidneys (p>0.05 each). CONCLUSION: BOLD-MRI is able to detect even mild tubular injury but necessitates a tubule-specific pharmacological maneuver, e.g. blocking the Na+-K+-2Cl- transporter by furosemide.


Subject(s)
Kidney Tubular Necrosis, Acute/diagnostic imaging , Magnetic Resonance Imaging/methods , Acute Kidney Injury/diagnostic imaging , Adult , Case-Control Studies , Cross-Sectional Studies , Female , Furosemide/administration & dosage , Humans , Male , Methods , Middle Aged , Oxygen/blood
SELECTION OF CITATIONS
SEARCH DETAIL