Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
Add more filters

Country/Region as subject
Affiliation country
Publication year range
1.
Europace ; 25(1): 146-155, 2023 02 08.
Article in English | MEDLINE | ID: mdl-35942655

ABSTRACT

AIMS: Activation mapping of premature atrial complexes (PACs) proves challenging due to interference by mechanical bumping and non-targeted ectopies. This study aims to compare the mapping efficacy, instant success, and long-term recurrence of catheter ablation for PACs with non-pulmonary vein (PV) and non-superior vena cava (SVC) origins between the novel dual-reference approach (DRA) and the routine single-reference approach (SRA) of mapping. METHODS AND RESULTS: Patients with symptomatic, drug-refractory PACs, or frequent residual PACs after atrial tachyarrhythmia ablation were enrolled. During activation mapping, the coronary sinus (CS) catheter was used as the only timing reference in the SRA group. In the DRA group, another catheter, which was spatially separated from the CS catheter, was used as the second reference. The timing difference between the two references was used to discriminate the targeted PACs from the uninterested rhythms. Procedural parameters and long-term recurrence were compared. A total of 188 patients (109 in SRA and 79 in DRA) were enrolled. The baseline characteristics were similar. Compared with the SRA group, the DRA group had less repeated mapping (1.2 ± 0.4 vs. 1.4 ± 0.5, P = 0.004), shorter mapping (15 ± 6 vs. 23 ± 7 min, P < 0.001) and procedural time (119 ± 28 vs. 132 ± 22 min, P = 0.001), similar procedural complication rates (3.6 vs. 3.8%, P > 0.999), higher instant success (96.2 vs. 87.2%, P = 0.039), and lower recurrence rate (15.2 vs. 29.3%, hazard ratio 1.943, P = 0.033) during a 24-month follow-up. CONCLUSION: As a novel strategy, the DRA shortens the procedural time and improves both instant and long-term success of PAC ablation, serving as a promising approach in mapping PACs with non-PV and non-SVC origins.


Subject(s)
Atrial Fibrillation , Atrial Premature Complexes , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Treatment Outcome , Pulmonary Veins/surgery , Atrial Premature Complexes/diagnosis , Atrial Premature Complexes/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
2.
Echocardiography ; 39(1): 118-121, 2022 01.
Article in English | MEDLINE | ID: mdl-34866231

ABSTRACT

Prevalence of primary coronary cameral fistula (CCF) is extremely rare, especially for CCF with its drainage channel into the left ventricle (LV). We describe a 45-year-old male patient with giant aneurysm associated with proximal right coronary artery (RCA), and the distal end of RCA draining into the LV through a fistula, which was discovered by echocardiography. Dual-source computer tomography revealed only the CCF-related giant RCA aneurysm. The drainage site of the fistula and the above coexistent abnormality could not be visualized clearly by coronary artery angiography because of deficient contrast medium filling into the aneurysm. The patient underwent surgical resection of the giant aneurysm and occlusion of the fistula in 2015. Finally, the patient accepted another operation to occlude the residual coronary fistula in 2021.


Subject(s)
Coronary Aneurysm , Fistula , Coronary Aneurysm/surgery , Coronary Angiography/methods , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Fistula/complications , Fistula/diagnostic imaging , Fistula/surgery , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Humans , Male , Middle Aged
3.
J Cardiovasc Electrophysiol ; 32(10): 2655-2664, 2021 10.
Article in English | MEDLINE | ID: mdl-34428342

ABSTRACT

OBJECTIVES: To explore the value of detecting the peri-device leak (PDL) and device endothelialization after left atrial appendage closure (LAAC) by cardiac computed tomography (CT) in patients with atrial fibrillation (AF), who underwent Watchman LAAC combined with radiofrequency ablation of atrial fibrillation (AFCA). METHODS: Patients with symptomatic drug-refractory atrial fibrillation at high risk of stroke (CHA2 DS2 -VASc Score ≥ 2), who underwent Watchman LAAC combined with AFCA in our center from March 2017 to December 2018 were enrolled. Maximum diameter of LAA orifice was determined by preoperative CCTA. A standardized view of Watchman device was obtained by postoperative CCTA multiplannar reconstruction to evaluate the PDL and device endothelialization. RESULTS: Approximately 84 patients post successful LAAC and AFCA were enrolled in this study. The satisfactory LAA occlusion rate was 100%. There was no death, bleeding, stroke, and device-related thrombus (DRT) events. At 6-month postprocedure, CCTA images evidenced complete endothelialization in 44 patients (no contrast enhancement in LAA); contrast enhancement in LAA and visible PDL in 33 patients; contrast enhancement in LAA but without PDL in seven patients (incomplete device endothelialization). Maximum diameter of LAA orifice could independently predict the occurrence of PDL (odds ratio, 1.31; 95% confidence interval, 1.11-1.55; p = .002), sensitivity was 69.7% and specificity was 80.4% with the cutoff value of maximum diameter of LAA orifice more than 28.2 mm on predicting PDL. CONCLUSIONS: CCTA is feasible to evaluate PDL and device endothelialization after LAAC. The maximum diameter of LAA orifice derived from CT can independently predict the occurrence of post-LAAC PDL.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Radiofrequency Ablation , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Computed Tomography Angiography , Echocardiography, Transesophageal , Humans , Prospective Studies , Tomography, X-Ray Computed , Treatment Outcome
4.
J Cardiovasc Pharmacol ; 78(2): 192-201, 2021 08 01.
Article in English | MEDLINE | ID: mdl-34029268

ABSTRACT

ABSTRACT: Enhancer of zeste homolog 2(EZH2) is an enzymatic subunit of polycomb repressive complex 2 (PRC2) and is responsible for catalyzing mono-, di-, and trimethylation of histone H3 at lysine-27(H3K27me1/2/3). Many noncoding RNAs or signaling pathways are involved in EZH2 functional alterations. This new epigenetic regulation of target genes is able to silence downstream gene expression and modify physiological and pathological processes in heart development, cardiomyocyte regeneration, and cardiovascular diseases, such as hypertrophy, ischemic heart diseases, atherosclerosis, and cardiac fibrosis. Targeting the function of EZH2 could be a potential therapeutic approach for cardiovascular diseases.


Subject(s)
Cardiovascular Diseases/metabolism , Enhancer of Zeste Homolog 2 Protein/metabolism , Epigenesis, Genetic , Heart/growth & development , Myocardium/metabolism , Animals , Cardiovascular Diseases/genetics , Cardiovascular Diseases/pathology , Cardiovascular Diseases/physiopathology , Enhancer of Zeste Homolog 2 Protein/genetics , Gene Expression Regulation, Developmental , Heart/physiopathology , Humans , Morphogenesis , Myocardium/pathology , Signal Transduction
5.
J Interv Cardiol ; 2020: 8615410, 2020.
Article in English | MEDLINE | ID: mdl-32669982

ABSTRACT

AIM: The feasibility and safety of performing the combined procedure of catheter ablation (CA) and left atrial appendage closure (LAAC) for atrial fibrillation (AF) have been reported by observational studies without controls. The aim of this study was to compare the procedural and long-term outcomes of combined procedures with isolated CA or LAAC. METHODS AND RESULTS: This study included patients who underwent combined CA and LAAC (combined group), CA alone (CA-only group), or LAAC alone (LAAC-only group). Propensity score matching was used to select controls from the CA-only and LAAC-only groups. Each group contained 76 subjects. The procedures were successfully performed in all the patients. Procedure-related complications of the combined group included one pericardial effusion and two groin haematomas, which did not differ significantly with those of the CA-only group (3.9% vs. 2.6%, P=0.650) or the LAAC-only group (3.9% vs. 2.6%, P=0.650), respectively. The AF-free rate of the combined group was comparable with that of the CA-only group after a mean of 2 years follow-up (67.1% vs. 69.7%, P=0.727). Compared with the LAAC-only group, the combined group achieved similar complete occlusion rate at implant (94.7% vs. 93.4%) and at 45 days (82.9% vs. 85.5%). At the end of follow-up, ischemic stroke and bleeding events of the combined group were low (3.9%) and were comparable with those of the CA-only group (5.3%) and the LAAC-only group (2.6%). CONCLUSIONS: The combination of AF-CA and LAAC is safe and efficacious compared with single procedures alone.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Catheter Ablation , Postoperative Complications , Prosthesis Implantation , Septal Occluder Device , Aged , Atrial Fibrillation/complications , Case-Control Studies , Catheter Ablation/adverse effects , Catheter Ablation/methods , Female , Humans , Male , Postoperative Complications/diagnosis , Postoperative Complications/etiology , Prosthesis Implantation/adverse effects , Prosthesis Implantation/instrumentation , Prosthesis Implantation/methods , Stroke/etiology , Stroke/prevention & control , Treatment Outcome
6.
J Clin Lab Anal ; 34(3): e23104, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31917884

ABSTRACT

BACKGROUND: Galectin-3 is an inflammatory marker that is raised in myocardial fibrosis and inflammation. Recent studies have explored its role in predicting atrial fibrillation (AF) outcomes. The aim of this systematic review and meta-analysis is to examine the association between serum concentration of galectin-3 and AF. METHODS: PubMed, EMBASE, and the Cochrane Database were searched. A total of 280 studies were identified, of which 28 studies involving 10 830 patients were included in our meta-analysis. RESULTS: Galectin-3 is present at higher concentrations in patients with AF than those in sinus rhythm (mean difference [MD] = -0.68 ng/mL, 95% CI: -0.92, -0.44, Z = 5.61, P < .00001). Galectin-3 levels were significantly higher in the persistent AF than in the paroxysmal AF group (MD = -0.94 ng/mL, 95% CI: -1.85, -0.03, Z = 2.04, P = .04). Higher galectin-3 levels were associated with a 45% increase in the odds of developing AF (odds ratio [OR] = 1.45, 95% CI: 1.15, 1.83, Z = 3.11, P = .002) and risk of AF recurrence (hazard ratio [HR] =1.17, 95% CI: 1.06, 1.29, Z = 3.12, P = .002). CONCLUSIONS: Our meta-analysis found that galectin-3 is significantly higher in patients with persistent AF than in those with paroxysmal AF, and can predict both AF development and recurrence after treatment.


Subject(s)
Atrial Fibrillation/blood , Galectin 3/blood , Aged , Blood Proteins , Female , Galectins , Humans , Male , Middle Aged , Risk Factors
7.
J Cardiovasc Electrophysiol ; 30(11): 2377-2386, 2019 11.
Article in English | MEDLINE | ID: mdl-31512322

ABSTRACT

AIMS: Ventricular arrhythmias (VAs) originating from the para-Hisian region represent a challenging location. The long-term success rate of catheter ablation above the septal leaflet of the tricuspid valve is not ideal. This study aimed to investigate the safety and efficacy of catheter ablation for para-Hisian VAs via a direct approach under the septal valve with reversed C-curve technique. METHODS AND RESULTS: Twenty-five consecutive patients with para-Hisian VAs were included. Systematic mapping was performed in the right ventricle septum, including both the regions above and under the septal valve. Radiofrequency (RF) ablation was preferentially performed under the valve with reversed C-curve technique in all patients. If the ablation failed under the valve, it was then performed above the valve and even in aortic sinus cusps. The earliest ventricular activation preceding surface QRS (V-QRS) under the valve was significantly larger than that above the valve (34.8 ± 5.3 vs 27.8 ± 5.7 ms, P < .01). RF ablation under the valve with reversed C-curve technique achieved acute success in 22 of 25 (88%) patients. Junctional rhythm developed during ablation in 3 of 25 (12%) patients and no atrioventricular block occurred. In the remaining three patients, RF application above the valve failed to eliminate the VAs and one of them achieved successful ablation in the right coronary cusp. During a mean follow-up of 17.8 ± 9.4 months, no patients presented with VAs recurrence and no postprocedure complications occurred. CONCLUSIONS: Catheter ablation under the valve with reversed C-curve technique shows to be effective and safe for para-Hisian VAs.


Subject(s)
Bundle of His/surgery , Catheter Ablation , Heart Rate , Tachycardia, Ventricular/surgery , Ventricular Premature Complexes/surgery , Action Potentials , Aged , Bundle of His/physiopathology , Catheter Ablation/adverse effects , Female , Humans , Male , Middle Aged , Retrospective Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/physiopathology , Time Factors , Treatment Outcome , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/physiopathology
8.
J Cardiovasc Electrophysiol ; 30(10): 1868-1876, 2019 10.
Article in English | MEDLINE | ID: mdl-31353748

ABSTRACT

INTRODUCTION: Catheter ablation of atrial fibrillation (AFCA) and left atrial appendage closure (LAAC) exert opposite effects on left atrial (LA) size. We aim to observe the net impact of combined AFCA and LAAC strategy on LA size and explore those factors which might affect the postprocedure LA structural remodeling. METHODS: A total of 53 patients, who underwent combined AFCA and Watchman LAAC in our center from March to December 2017, were enrolled. Atrial fibrillation (AF) recurrence was monitored after the procedure. Left atrial volume (LAV) and left atrial appendage volume (LAAV) were measured by Mimics based on dual-source computed tomography images. RESULTS: At 6 months, sinus rhythm (SR) was maintained in 79.2% patients. LAV was significantly reduced (130.2 ± 36.3 mL to 107.1 ± 30.0 ml; P < .001) in SR maintenance group, but not in AF recurrence group (138.8 ± 39.3 mL to 137.9 ± 36.9 mL; P = .671). In SR group, preoperative LAAV/LAV ratio (B = -0.894; P = .015), NT-proBNP (B = 0.005; P = .019) and left ventricular ejection fraction (LVEF) (B = -0.778; P < .001) could interactively affect the extent of postoperative LA structural reverse remodeling, among which LAAV/LAV ratio could independently predict the significance of reverse remodeling (≥15% reduction in LAV) (OR, 0.56; 95% CI, 0.34-0.90; P = .018). A preoperative LAAV/LAV ratio less than 7.1% is indicative of significant LA structural reverse remodeling in this patient cohort. CONCLUSIONS: LA structural reverse remodeling could be evidenced in patients with maintained SR following combined AFCA and LAAC. Smaller LAAV/LAV ratio, higher NT-proBNP or lower LVEF at baseline are associated with more significant LA structural reverse remodeling, while LAAV/LAV ratio can predict the significance of the process after one-stop treatment.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Atrial Function, Left , Atrial Remodeling , Cardiac Surgical Procedures , Catheter Ablation , Action Potentials , Aged , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Cardiac Surgical Procedures/adverse effects , Cardiac Surgical Procedures/instrumentation , Catheter Ablation/adverse effects , Female , Fibrosis , Heart Rate , Humans , Male , Middle Aged , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
9.
Int Heart J ; 60(1): 63-70, 2019 Jan 25.
Article in English | MEDLINE | ID: mdl-30464131

ABSTRACT

Left atrial appendage (LAA) closure (LAAC) has emerged as an alternative therapeutic approach to medical therapy for stroke prevention in patients with nonvalvular atrial fibrillation (NVAF). However, complex LAA anatomy may preclude its use. LAmbre is a new, self-expanding LAA occluder, and is highly adaptable to different LAA morphologies. We explored the feasibility, safety, and efficacy of LAAC using LAmbre device in NVAF patients with or without prior catheter ablation (CA). LAAC using LAmbre device was applied in NVAF patients with (group C) or without (group N) prior CA. Transesophageal echocardiography (TEE) was performed at 3, and 12 months post-LAAC. Among 17 LAAC patients (group C, 6 & group N, 11), 4 cases were implanted with special type devices, 5 were implanted with large devices. Besides one case of cardiac tamponade (N group), there were two minor peri-procedural complications only. Successful sealing of the LAA was documented in all the patients (100%) by TEE both post LAAC and at 3 months. At 3 months, no residual flow was achieved in 11 patients (64.7%); six patients (35.3%) had residual flow < 5 mm. There was no device dislocation or leakage during the mean of 30 months follow up. At 545 days after LAAC, one patient in group C experienced sudden death. Baseline, peri-procedural, and follow-up characteristics were similar between two groups (P > 0.05). LAAC with LAmbre device, subsequent to prior CA for AF, can be performed successfully and safely. The design and distinguishing features of this device could be of help in patients with complex anatomy of LAA.


Subject(s)
Atrial Appendage/diagnostic imaging , Atrial Fibrillation/surgery , Cardiac Surgical Procedures/instrumentation , Aged , Atrial Appendage/surgery , Atrial Fibrillation/diagnostic imaging , Catheter Ablation , Echocardiography, Transesophageal , Feasibility Studies , Female , Humans , Male , Prosthesis Design , Septal Occluder Device , Treatment Outcome
11.
J Cardiovasc Pharmacol ; 66(3): 270-5, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26348825

ABSTRACT

For decades, digoxin has been widely used to control ventricular rate in atrial fibrillation (AF). However, it remains controversial as to whether digoxin is associated with increased mortality in AF. In this study, we searched relevant studies that were published before December 1, 2014, in PubMed, EMBASE, and the Cochrane central databases. We systematically reviewed the references and performed a meta-analysis of 8 carefully selected studies with 302,738 patients who were included for the final analysis. It was shown that digoxin use was associated with increased risk of all-cause mortality in AF overall [hazard ratio (HR) = 1.375, 95% confidence intervals (CI), 1.201-1.574, P = 0.0001]. Subgroup analysis further revealed that digoxin was associated with increased all-cause mortality in patients with AF, which was complicated by heart failure (HF) (HR = 1.201, CI, 1.074- 1.344, P = 0.001), and in those subjects without HF (HR = 1.172, CI, 1.148-1.198, P = 0.0001). Sensitivity analyses found results to be robust. Our findings indicated that digoxin use was associated with significantly increased all-cause mortality in patients with AF regardless of concomitant HF. We suggest that digoxin should not be preferentially used over other rate control medications in AF.


Subject(s)
Anti-Arrhythmia Agents/adverse effects , Atrial Fibrillation/mortality , Digoxin/adverse effects , Heart Failure/mortality , Anti-Arrhythmia Agents/administration & dosage , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/complications , Atrial Fibrillation/drug therapy , Data Interpretation, Statistical , Databases, Factual , Digoxin/administration & dosage , Digoxin/therapeutic use , Heart Failure/complications , Heart Failure/drug therapy , Humans , Mortality/trends
13.
Int J Cardiol ; 397: 131640, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38065326

ABSTRACT

BACKGROUND: The residual device patency (RDP) after left atrial appendage closure (LAAC) with the LACbes device has not been specifically explored in atrial fibrillation (AF) patients. This study aims to explore the incidence, impact and predictors of RDP detected by cardiac computed tomography angiography (CCTA) post LAAC. METHODS: AF patients implanted with the LACbes device were prospectively enrolled. CCTA device surveillance was performed at 3 months post-procedure. Major adverse events (MAEs), including stroke/transient ischemic attack, major bleeding and all-cause death, were evaluated. RESULTS: Among 141 patients with CCTA surveillance, 56 (39.7%) showed no visible leak and 85 (60.3%) showed RDP. During the median follow-up of 443 [232, 706] days, the presence of RDP was not associated with an increased risk of MAEs (adjusted hazard ratio [HR]: 4.07, 95% confidence interval [CI]: 0.49-34.24, p = 0.196), while peri-device leak (PDL) at the lobe was associated with heightened risks of MAEs (adjusted HR: 6.85, 95% CI: 1.62-28.89, p = 0.009). In patients with PDL at the lobe, antiplatelet after 6 months (HR: 0.20, 95% CI: 0.05-0.91, p = 0.038) was independent protective predictor of MAEs. Besides, current smoking (odds ratio [OR]: 7.52, 95% CI: 2.68-21.08, p < 0.001) and maximum diameter of LAA orifice (OR: 1.16, 95% CI: 1.00-1.34, p = 0.048) were independent predictors of PDL at the lobe. CONCLUSIONS: Presence of PDL at the device lobe detected by CCTA at 3-month post LAAC with LACbes is associated with unfavorable prognosis in AF patients. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03788941.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Cardiac Catheterization , Echocardiography, Transesophageal , Incidence , Left Atrial Appendage Closure , Prostheses and Implants/adverse effects , Stroke/epidemiology , Treatment Outcome
14.
Circ Cardiovasc Interv ; 17(5): e013579, 2024 May.
Article in English | MEDLINE | ID: mdl-38629273

ABSTRACT

BACKGROUND: The prognostic impact of left atrial appendage (LAA) patency, including those with and without visible peri-device leak (PDL), post-LAA closure in patients with atrial fibrillation, remains elusive. METHODS: Patients with atrial fibrillation implanted with the WATCHMAN 2.5 device were prospectively enrolled. The device surveillance by cardiac computed tomography angiography was performed at 3 months post-procedure. Adverse events, including stroke/transient ischemic attack (TIA), major bleeding, cardiovascular death, all-cause death, and the combined major adverse events (MAEs), were compared between patients with complete closure and LAA patency. RESULTS: Among 519 patients with cardiac computed tomography angiography surveillance at 3 months post-LAA closure, 271 (52.2%) showed complete closure, and LAA patency was detected in 248 (47.8%) patients, including 196 (37.8%) with visible PDL and 52 (10.0%) without visible PDL. During a median of 1193 (787-1543) days follow-up, the presence of LAA patency was associated with increased risks of stroke/TIA (adjusted hazard ratio for baseline differences, 3.22 [95% CI, 1.17-8.83]; P=0.023) and MAEs (adjusted hazard ratio, 1.12 [95% CI, 1.06-1.17]; P=0.003). Specifically, LAA patency with visible PDL was associated with increased risks of stroke/TIA (hazard ratio, 3.66 [95% CI, 1.29-10.42]; P=0.015) and MAEs (hazard ratio, 3.71 [95% CI, 1.71-8.07]; P=0.001), although LAA patency without visible PDL showed higher risks of MAEs (hazard ratio, 3.59 [95% CI, 1.28-10.09]; P=0.015). Incidences of stroke/TIA (2.8% versus 3.0% versus 6.7% versus 22.2%; P=0.010), cardiovascular death (0.9% versus 0% versus 1.7% versus 11.1%; P=0.005), and MAEs (4.6% versus 9.0% versus 11.7% versus 22.2%; P=0.017) increased with larger PDL (0, >0 to ≤3, >3 to ≤5, or >5 mm). Older age and discontinuing antiplatelet therapy at 6 months were independent predictors of stroke/TIA and MAEs in patients with LAA patency. CONCLUSIONS: LAA patency detected by cardiac computed tomography angiography at 3 months post-LAA closure is associated with unfavorable prognosis in patients with atrial fibrillation implanted with WATCHMAN 2.5 device. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03788941.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Catheterization , Computed Tomography Angiography , Ischemic Attack, Transient , Stroke , Humans , Atrial Appendage/physiopathology , Atrial Appendage/diagnostic imaging , Male , Female , Aged , Atrial Fibrillation/physiopathology , Atrial Fibrillation/mortality , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrial Fibrillation/diagnostic imaging , Prospective Studies , Risk Factors , Ischemic Attack, Transient/etiology , Time Factors , Treatment Outcome , Stroke/etiology , Stroke/mortality , Aged, 80 and over , Middle Aged , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Risk Assessment , Hemorrhage , Prosthesis Design
15.
JACC Asia ; 3(1): 138-149, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36873751

ABSTRACT

Background: More than 40% of left atrial appendage closure (LAAC) procedures were combined with atrial fibrillation (AF) ablation in China. Objectives: This study aimed to assess the sex differences in the combined radiofrequency catheter ablation and LAAC procedures. Methods: Data from the LAACablation (Left Atrial Appendage Closure in Combination With Catheter Ablation) registry, which enrolled AF patients who underwent the combined procedure between 2018 and 2021, were analyzed. Procedural complications, long-term outcomes, and quality of life (QoL) were compared between sexes. Results: Of 931 patients, 402 (43.2%) were women. Compared with men, women were older (age 71.3 ± 7.4 years vs 68.7 ± 8.1 years; P < 0.001), presented more often with paroxysmal AF (52.5% vs 42.7%; P < 0.003), and had higher CHA2DS2-VASc scores (4.1 ± 1.5 vs 3.1 ± 1.5; P < 0.001), but received less often linear ablation and had shorter total procedural times and radiofrequency catheter ablation times. Women had similar rates of total and major procedural complications but presented with a higher incidence of minor complications than men (3.7% vs 1.3%; P = 0.027). Follow-up over 1,812 patient-years revealed similar adverse events between women and men, including all-cause death (HR: 0.89; 95% CI: 0.43-1.85; P = 0.754), thromboembolic events (HR: 1.17; 95% CI: 0.54-2.52; P = 0.697), major bleeding (HR: 0.96; 95% CI: 0.38-2.44; P = 0.935), and their composite (HR: 0.85; 95% CI: 0.56-1.28; P = 0.434). The recurrence rates of atrial tachyarrhythmia were also comparable between sexes presenting either paroxysmal or persistent AF. Women were seen with greater QoL impairment at baseline, but the sex gap narrowed at 1-year follow-up. Conclusions: In AF patients who underwent the combined procedure, women had similar procedural safety and long-term efficacy to men and presented greater QoL improvement. (Left Atrial Appendage Closure in Combination With Catheter Ablation [LAACablation]; NCT03788941).

16.
Diagnostics (Basel) ; 13(21)2023 Oct 26.
Article in English | MEDLINE | ID: mdl-37958221

ABSTRACT

BACKGROUND: Managing patients with atrial fibrillation (AF) and comorbid heart failure (HF) with reduced (HFrEF) or mildly reduced ejection fraction (HFmrEF) is of clinical importance but a great challenge. This study aimed to evaluate the clinical benefit of the combined radiofrequency catheter ablation (RFCA) and left atrial appendage closure (LAAC) procedure in AF patients complicated with systolic HF. METHODS: AF patients with HFrEF or HFmrEF who underwent the combined RFCA and LAAC procedure were prospectively enrolled in the LAACablation registry. The procedural complications and long-term outcomes were evaluated. Another cohort of AF patients with systolic HF who did not undergo either RFCA or LAAC were used for prognosis comparison. RESULTS: Among 802 AF patients who underwent the combined procedure, 65 patients were comorbid with systolic HF (25 with HFrEF and 40 with HFmrEF). The overall procedural complication rate was 9.2%, which was mainly attributed to acute decompensated HF (6.2%). Accompanied with markedly reduced AF burden (from median [25th, 75th percentile]: 100 [100, 100] to 0 [0, 1.2]%, p < 0.001), upward trajectories of cardiac function were observed in 51 (78.4%) patients, showing improvement in New York Heart Classification (p < 0.01), natriuretic peptide levels (from 1492 [809, 3259] to 413 [163, 880] pg/mL, p < 0.001) and left ventricular EF (from 42.6 ± 5.3 to 53.8 ± 8.2%, p < 0.001). During the 27-month follow-up period, death, thromboembolism, major bleeding, and HF rehospitalization were observed in three, one, one, and four patients, respectively. The observed event rates showed a significant reduction compared with the non-procedure AF-HF cohort (n = 138; for composite endpoint: hazard ratio: 2.509, 95% confidence interval: 1.415-4.449, p = 0.002) and with the respective rates predicted by risk scores. CONCLUSIONS: Combining RFCA and LAAC achieves acceptable safety and credible long-term efficacy in AF patients with systolic HF. Further randomized studies are warranted in a larger patient cohort.

17.
Clin Cardiol ; 46(10): 1202-1209, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37522390

ABSTRACT

BACKGROUND: Catheter ablation (CA) combined with left atrial appendage occlusion (LAAO) is a feasible approach for atrial fibrillation (AF) patients. Its role in octogenarians with AF is unclear. HYPOTHESIS: In AF patients over 80 years, CA combined with LAAO is a feasible way in restoring sinus rhythm and preventing stroke. METHODS: This is a single-center retrospective study. Patients who underwent CA and LAAO in a single procedure between March 2018 and December 2020 were included. Efficacy endpoints included procedural success rate, AF recurrence rate, and thromboembolic events. Safety endpoints included pericardial effusion/cardiac tamponade, device-related thrombus (DRT), all-cause death, and major bleeding. RESULTS: Five hundred and five patients (mean age 69.5 ± 7.7 years; 230 [45.5%] female) were included, with 46 (9.1%) patients aged ≥80 years old (octogenarian group). Prevalence of paroxysmal AF (25 [54.3%] vs. 207 [45.1%], p < 0.001) and CHA2DS2VASc score (4.1 ± 1.3 vs. 3.1 ± 1.4, p < 0.0001) were higher in octogenarian patients. There were six cases (1.2%) of pericardial effusion (all in nonoctogenarian patients). At 3 months postprocedure, 437 patients underwent TEE/CT. Thirty-two (80%) octogenarian patients and 308 (77.6%) nonoctogenarian patients had no peri-device leak. After a mean follow-up of 26.9 ± 9.1 months, AF was documented in 10 (21.7%) patients in octogenarian group and in 103 (22.4%) patients in nonoctogenarian group (p = 0.99). The annual thromboembolic risk was 2.1% and 0.8% in the octogenarian group and nonoctogenarian group, respectively. Death occurred in 16 nonoctogenarian patients. One major bleeding was recorded in the octogenarian group. CONCLUSIONS: The combination of CA and LAAO in a single procedure is a feasible treatment option in octogenarians with comparable efficacy and safety profile.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Pericardial Effusion , Stroke , Thromboembolism , Aged, 80 and over , Humans , Female , Middle Aged , Aged , Male , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Octogenarians , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Pericardial Effusion/diagnosis , Pericardial Effusion/epidemiology , Pericardial Effusion/etiology , Retrospective Studies , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Hemorrhage , Treatment Outcome
18.
Am J Cardiol ; 204: 312-319, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37567023

ABSTRACT

Left atrial appendage closure (LAAC) proved to be noninferior to oral anticoagulation (OAC) in nonablated patients with atrial fibrillation (AF). This study aimed to compare the efficacy and safety of LAAC with those of OAC therapy in patients after AF ablation. This study included patients who underwent catheter ablation (CA) of AF between January 2016 and December 2020. The cohort was divided into CA + LAAC and CA + OAC, where propensity score matching was used to select controls, and each group contained 682 subjects. The enrolled patients' mean age was 70.34 ± 8.32 years, and 47.3% were female; their CHA2DS2-VASc score was 3.48 ± 1.17. Baseline characteristics were similar between groups. After a 3-year mean follow-up, the incidence of thromboembolic events was 1.25 and 1.10 and that of major bleeding events was 0.65 and 1.72 per 100 patient-years in the CA + LAAC, and CA + OAC groups, respectively. The rate of thromboembolisms and major adverse cardiovascular events was similar between the 2 groups (hazard ratio [HR] 1.162, 95% confidence interval [CI] 0.665 to 2.030, p = 0.598, HR 0.711, 95% CI 0.502 to 1.005, p = 0.053); however, that of major bleeding and all-cause death was significantly reduced with LAAC (HR 0.401, 95% CI 0.216 to 0.746, p = 0.004, HR 0.528, 95% CI 0.281 to 0.989, p = 0.046). There was no significant difference in periprocedural complications (p >0.05) and the rate of AF recurrence (OAC vs LAAC: 39.44% vs 40.62%, p = 0.658). LAAC is a reasonable and safer alternative to OAC therapy in high-risk patients after AF ablation.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Stroke , Thromboembolism , Humans , Female , Middle Aged , Aged , Male , Atrial Fibrillation/complications , Atrial Fibrillation/surgery , Treatment Outcome , Atrial Appendage/surgery , Hemorrhage/chemically induced , Thromboembolism/epidemiology , Thromboembolism/etiology , Thromboembolism/prevention & control , Anticoagulants/therapeutic use , Catheter Ablation/adverse effects , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control
19.
Heliyon ; 9(1): e12662, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36691523

ABSTRACT

Background: Left atrial appendage (LAA) closure (LAAC) in atrial fibrillation (AF) patients with the reversed chicken-wing (RCW) LAA is challenging. Aims: To elucidate the LAAC strategy of the RCW-LAA. Methods: A total of 802 AF patients who were enrolled in the LAACablation registry for LAAC procedure were included, 55 of whom presented with the RCW-LAA. The WATCHMAN device was implanted using the standard protocol when the sheath depth was no less than the device depth (the simple group). For those with a sheath depth of less than the device depth (the complex group), device deployment was attempted with acceptable protrusion or after a repeated atrial transseptal puncture (re-ATP) at a more inferior and anterior position. The anatomical and procedural features were compared between groups and before and after the re-ATP. Results: The success rate of LAAC was significantly lower in patients with the RCW-LAA than with the other morphologies (92.7% vs. 98.8%, p = 0.001). Compared with the simple group, the complex group had shorter root depth and shorter neck length, and more LAAs in the complex group were at lower position (all p < 0.05). The sheath depth after the re-ATP was significantly greater than that before the re-ATP (18.8 ± 3.4 mm vs. 14.7 ± 2.6 mm, p < 0.001). For the patients who underwent re-ATP, the sheath went significantly deeper in successful procedures than in aborted procedures (19.7 ± 3.3 mm vs. 15.8 ± 1.8 mm, p = 0.040). Conclusions: The anatomical features of the RCW-LAA were related to the complexity of the LAAC procedure. The re-ATP at an inferior and anterior location could increase the success rate of LAAC. ClinicalTrialsgov: NCT03788941.

20.
JACC Clin Electrophysiol ; 9(12): 2477-2490, 2023 12.
Article in English | MEDLINE | ID: mdl-37831033

ABSTRACT

BACKGROUND: Multifocal ectopic Purkinje-related premature contractions (MEPPCs) are associated with SCN5A variants. However, it is not well understood why Purkinje fibers, but not ventricular myocardium, play a predominant role in arrhythmogenesis. OBJECTIVES: This study sought to explore the underlying mechanisms of MEPPC. METHODS: Whole-cell patch-clamp and molecular biology techniques were used in the present study. RESULTS: Clinical data from one patient with R814W variant showed MEPPC syndrome, which is well responsive to amiodarone. Compared with canine ventricular myocytes, Purkinje cells (PCs) had significantly larger sodium current (INa), leftward shift of INa activation and inactivation curves, suggesting higher sodium channel excitability in PCs. Real-time polymerase chain reaction and Western blot analysis showed that the mRNA and protein expression of NaVß1 and NaVß3 was higher in canine Purkinje fibers than in ventricular myocardium. INa in heterologous Chinese hamster ovary cell expression system co-expressing NaV1.5 and NaVß1/NaVß3 exhibited similar biophysical properties of INa in PCs. R814W variant shifted INa activation in a hyperdepolarized direction, caused a larger window current, and generated an outward-gating pore current at depolarized voltages. Coexpression of NaVß1/NaVß3 with Nav1.5-R814W further left-shifted INa activation and caused an even larger window current and gating pore current, suggesting higher susceptibility of Purkinje fibers to R814W variant. Amiodarone inhibited INa, shifted its inactivation to more negative voltages, and significantly decreased the window current. CONCLUSIONS: A higher expression of ß1 and ß3 subunits contributes to higher sodium channel excitability in cardiac Purkinje fibers, making them more susceptible to MEPPC.


Subject(s)
Amiodarone , Purkinje Fibers , Cricetinae , Humans , Animals , Dogs , CHO Cells , Cricetulus , Arrhythmias, Cardiac/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL