Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 59
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Cancer ; 128(14): 2796-2805, 2022 07 15.
Article in English | MEDLINE | ID: mdl-35536104

ABSTRACT

BACKGROUND: The European Organization for Research and Treatment of Cancer 22092-62092 STRASS trial failed to demonstrate the superiority of neoadjuvant radiotherapy (RT) over surgery alone in patients with retroperitoneal sarcoma. Therefore, an RT quality-assurance program was added to the study protocol to detect and correct RT deviations. The authors report results from the trial RT quality-assurance program and its potential effect on patient outcomes. METHODS: To evaluate the effect of RT compliance on survival outcomes, a composite end point was created. It combined the information related to planning target volume coverage, target delineation, total dose received, and overall treatment time into 2 groups: non-RT-compliant (NRC) for patients who had unacceptable deviation(s) in any of the previous categories and RT-compliant (RC) otherwise. Abdominal recurrence-free survival (ARFS) and overall survival were compared between the 2 groups using a Cox proportional hazard model adjusted for known prognostic factors. RESULTS: Thirty-six of 125 patients (28.8%) were classified as NRC, and the remaining 89 patients (71.2%) were classified as RC. The 3-year ARFS rate was 66.8% (95% confidence interval [CI], 55.8%-75.7%) and 49.8% (95% CI, 32.7%-64.8%) for the RC and NRC groups, respectively (adjusted hazard ratio, 2.32; 95% CI, 1.25-4.32; P = .008). Local recurrence after macroscopic complete resection occurred in 13 of 89 patients (14.6%) versus 2 of 36 patients (5.6%) in the RC and NRC groups, respectively. CONCLUSIONS: The current analysis suggests a significant benefit in terms of ARFS in favor of the RC group. This association did not translate into less local relapses after complete resection in the RC group. Multidisciplinary collaboration and review of cases are critical to avoid geographic misses, especially for rare tumors like retroperitoneal sarcoma.


Subject(s)
Guideline Adherence , Retroperitoneal Neoplasms , Sarcoma , Soft Tissue Neoplasms , Disease-Free Survival , Humans , Neoadjuvant Therapy , Neoplasm Recurrence, Local/pathology , Proportional Hazards Models , Randomized Controlled Trials as Topic , Retroperitoneal Neoplasms/radiotherapy , Retroperitoneal Neoplasms/surgery , Sarcoma/radiotherapy , Sarcoma/surgery , Soft Tissue Neoplasms/radiotherapy , Soft Tissue Neoplasms/surgery , Survival Rate
2.
Pediatr Blood Cancer ; 67(12): e28465, 2020 12.
Article in English | MEDLINE | ID: mdl-32902137

ABSTRACT

BACKGROUND: Long-term treatment-related toxicity may substantially impact well-being, quality of life (QoL), and health of children/adolescents with brain tumors (CBTs). Strategies to reduce toxicity include pencil beam scanning (PBS) proton therapy (PT). This study aims to report clinical outcomes and QoL in PBS-treated CBTs. PROCEDURE: We retrospectively reviewed 221 PBS-treated CBTs aged <18 years. Overall-free (OS), disease-free (DFS), and late-toxicity-free survivals (TFS), local control (LC) and distant (DC) brain/spinal control were calculated using Kaplan-Meier estimates. Prospective QoL reports from 206 patients (proxies only ≤4 years old [yo], proxies and patients ≥5 yo) were descriptively analyzed. Median follow-up was 51 months (range, 4-222). RESULTS: Median age at diagnosis was 3.1 years (range, 0.3-17.7). The main histologies were ependymoma (n = 88; 39.8%), glioma (n = 37; 16.7%), craniopharyngioma (n = 22; 10.0%), atypical teratoid/rhabdoid tumor (ATRT) (n = 21; 9.5%) and medulloblastoma (n = 15; 6.8%). One hundred sixty (72.4%) patients received chemotherapy. Median PT dose was 54 Gy(relative biological effectiveness) (range, 18.0-64.8). The 5-year OS, DFS, LC, and DC (95% CI) were 79.9% (74-85.8), 65.2% (59.8-70.6), 72.1% (65.4-78.8), and 81.8% (76.3-87.3), respectively. Late PT-related ≥G3 toxicity occurred in 19 (8.6%) patients. The 5-year ≥G3 TFS was 91.0% (86.3-95.7). Three (1.4%) secondary malignancies were observed. Patients aged ≤3 years at PT (P = .044) or receiving chemotherapy (P = .043) experienced more ≥G3 toxicity. ATRT histology independently predicted distant brain failure (P = .046) and death (P = .01). Patients aged ≥5 years self-rated QoL higher than their parents (proxy assessment). Both reported lower social functioning and cognition after PT than at baseline, but near-normal long-term global well-being. QoL was well below normal before and after PT in children ≤4 years. CONCLUSIONS: The outcome of CBTs was excellent after PBS. Few patients had late ≥G3 toxicity. Patients aged <5 years showed worse QoL and toxicity outcomes.


Subject(s)
Brain Neoplasms/radiotherapy , Proton Therapy/mortality , Quality of Life , Adolescent , Brain Neoplasms/pathology , Child , Child, Preschool , Female , Follow-Up Studies , Humans , Infant , Male , Prognosis , Prospective Studies , Radiotherapy Dosage , Retrospective Studies , Survival Rate
3.
Acta Oncol ; 58(10): 1423-1428, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31364904

ABSTRACT

Background: For proton therapy of paranasal tumors, field directions avoiding volumes that might change during therapy are typically used. If the plan is optimized on the daily anatomy using daily adapted proton therapy (DAPT) however, field directions crossing the nasal cavities might be feasible. In this study, we investigated the effectiveness of DAPT for enabling narrow-field treatment approaches. Material and methods: For five paranasal tumor patients, representing a wide patient spectrum, anatomically robust 4-field-star and narrow-field plans were calculated and their robustness to anatomical and setup uncertainties was compared with and without DAPT. Based on the nominal planning CTs, per patient up to 125 simulated CTs (simCTs) with different nasal cavity fillings were created and random translations and rotations due to patient setup uncertainties were further simulated. Plans were recalculated or re-optimized on all error scenarios, representing non-adapted and DAPT fractions, respectively. From these, 100 possible treatments (60 GyRBE, 30 fx) were simulated and changes in integral dose, target and organs at risk (OARs) doses evaluated. Results: In comparison to the 4-field-star approach, the use of narrow-fields reduced integral dose between 29% and 56%. If OARs did not overlap with the target, OAR doses were also reduced. Finally, the significantly reduced target coverage in non-adapted treatments (mean V95 reductions of up to 34%) could be almost fully restored with DAPT in all cases (differences <1%). Conclusions: DAPT was found to be not only an effective way to increase plan robustness to anatomical and positional uncertainties, but also opened the possibility to use improved and more conformal field arrangements.


Subject(s)
Dose Fractionation, Radiation , Paranasal Sinus Neoplasms/radiotherapy , Proton Therapy/methods , Radiation Injuries/prevention & control , Radiotherapy Planning, Computer-Assisted/methods , Feasibility Studies , Humans , Nasal Cavity , Organs at Risk/diagnostic imaging , Organs at Risk/radiation effects , Paranasal Sinus Neoplasms/diagnostic imaging , Paranasal Sinuses/diagnostic imaging , Proton Therapy/adverse effects , Radiation Injuries/etiology , Radiotherapy Dosage , Tomography, X-Ray Computed
4.
Acta Neurochir (Wien) ; 159(10): 1815-1823, 2017 10.
Article in English | MEDLINE | ID: mdl-28478512

ABSTRACT

BACKGROUND: The treatment of clival chordomas remains challenging. Total tumour resection is often impossible without hampering adjacent anatomical structures and causing functional sequelae. On the other hand, chordomas show limited response to non-surgical treatment modalities. Up to now, no well-established interdisciplinary treatment algorithms for clival chordomas exist. In this regard, we analysed the data from all patients that underwent interdisciplinary treatment for clival chordoma in our institution over the last 10 years. METHOD: Retrospective report of all patients treated at the authors' institution from 2005 to 2015. RESULTS: Thirteen patients underwent 24 surgeries, of which 2 (8%) were gross total resections and 22 (92%) incomplete resections. Neurological deterioration, endocrinological disturbances and other surgical complications were observed in six (25%), three (13%) and nine (38%) cases, respectively. Three surgeries (13%) led to an improvement of the initial preoperative neurological condition. All patients were discussed on the interdisciplinary tumour board and all underwent one type of radiotherapy following initial surgery: proton beam in 11 cases (85%) and photon beam in two (15%) cases. In the course of their recurrent disease, three patients (23%) received systemic therapy (imatinib, pazopanib and nivolumab). One patient received a personalised cellular immunotherapy. One patient (8%) was lost to follow-up. Of the remaining 12 patients, four patients (33%) died in the period of analysis; all deaths were chordoma-related. The 5-year cumulative survival rate was 83% (52-97%, CI 95%), 5-year progression-free survival rate was 53% (26-79%, CI 95%). The eight patients (66%) still alive had favourable outcome (KPS, 90 ± 10.7%). SF36 analysis among the survivors revealed 43 points for the Physical Component Summary (12% above, 38% at and 50% below the general population norm) and 47 points for the Mental Component Summary (25% above, 38% at and 38% below). CONCLUSIONS: Our patients show a low rate of gross total resection but an outcome well comparable to other published results. This emphasises the importance of interdispiplinary treatment strategies, with surgery supplying maximal safe resection and avoiding severe neurological deficit, allowing patients to undergo adjusted radiotherapy and other treatment options in a good condition.


Subject(s)
Chordoma/surgery , Cranial Fossa, Posterior/surgery , Skull Base Neoplasms/surgery , Adult , Aged , Antineoplastic Agents/therapeutic use , Chordoma/drug therapy , Chordoma/mortality , Chordoma/pathology , Combined Modality Therapy , Cranial Fossa, Posterior/pathology , Disease-Free Survival , Female , Humans , Male , Middle Aged , Neurosurgical Procedures , Radiosurgery , Retrospective Studies , Skull Base Neoplasms/drug therapy , Skull Base Neoplasms/mortality , Skull Base Neoplasms/pathology , Survival Rate , Treatment Outcome
7.
Radiat Oncol ; 19(1): 75, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38886727

ABSTRACT

BACKGROUND AND PURPOSE: Rare but severe toxicities of the optic apparatus have been observed after treatment of intracranial tumours with proton therapy. Some adverse events have occurred at unusually low dose levels and are thus difficult to understand considering dose metrics only. When transitioning from double scattering to pencil beam scanning, little consideration was given to increased dose rates observed with the latter delivery paradigm. We explored if dose rate related metrics could provide additional predicting factors for the development of late visual toxicities. MATERIALS AND METHODS: Radiation-induced intracranial visual pathway lesions were delineated on MRI for all index cases. Voxel-wise maximum dose rate (MDR) was calculated for 2 patients with observed optic nerve toxicities (CTCAE grade 3 and 4), and 6 similar control cases. Additionally, linear energy transfer (LET) related dose enhancing metrics were investigated. RESULTS: For the index cases, which developed toxicities at low dose levels (mean, 50 GyRBE), some dose was delivered at higher instantaneous dose rates. While optic structures of non-toxicity cases were exposed to dose rates of up to 1 to 3.2 GyRBE/s, the pre-chiasmatic optic nerves of the 2 toxicity cases were exposed to dose rates above 3.7 GyRBE/s. LET-related metrics were not substantially different between the index and non-toxicity cases. CONCLUSIONS: Our observations reveal large variations in instantaneous dose rates experienced by different volumes within our patient cohort, even when considering the same indications and beam arrangement. High dose rate regions are spatially overlapping with the radiation induced toxicity areas in the follow up images. At this point, it is not feasible to establish causality between exposure to high dose rates and the development of late optic apparatus toxicities due to the low incidence of injury.


Subject(s)
Brain Neoplasms , Proton Therapy , Radiation Injuries , Radiotherapy Dosage , Humans , Proton Therapy/adverse effects , Proton Therapy/methods , Brain Neoplasms/radiotherapy , Female , Male , Middle Aged , Adult , Radiation Injuries/etiology , Aged , Optic Nerve/radiation effects , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Dose-Response Relationship, Radiation
8.
Article in English | MEDLINE | ID: mdl-38772348

ABSTRACT

Purpose 4D computed tomography (4DCT) is the clinical standard to image organ motion in radiotherapy, although it is limited in imaging breathing variability. We propose a method to transfer breathing motion across longitudinal imaging datasets to include intra-patient variability and verify its performance in lung cancer patients. Methods Five repeated control 4DCTs for 6 non-small cell lung cancer patients were combined into multi-breath datasets (m4DCT) by merging stages of deformable image registration to isolate respiratory motion. The displacement of the centre of mass of the primary tumour and its volume changes were evaluated to quantify intra-patient differences. Internal target volumes defined on the m4DCT were compared with those conventionally drawn on the 4DCT. Results Motion analysis suggests no discontinuity at the junction between successive breaths, confirming the method's ability to merge repeated imaging into a continuum. Motion (variability) is primarily in superior-inferior direction and goes from 14.4 mm (8.7 mm) down to 0.1 mm (0.6 mm), respectively for tumours located in the lower lobes or most apical ones. On average, up to 65% and 74% of the tumour volume was subject to expansion or contraction in the inhalation and exhalation phases. These variations lead to an enlargement of the ITV up to 8% of its volume in our dataset. Conclusion 4DCT can be extended to model variable breathing motion by adding synthetic phases from multiple time-resolved images. The inclusion of this improved knowledge of patients' breathing allows better definition of treatment volumes and their margins for radiation therapy. .

9.
Phys Imaging Radiat Oncol ; 29: 100529, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38235286

ABSTRACT

Background and purpose: Imaging of respiration-induced anatomical changes is essential to ensure high accuracy in radiotherapy of lung cancer. We expanded here on methods for retrospective reconstruction of time-resolved volumetric magnetic resonance (4DMR) of the thoracic region and benchmarked the results against 4D computed tomography (4DCT). Materials and method: MR data of six lung cancer patients were collected by interleaving cine-navigator images with 2D data frame images, acquired across the thorax. The data frame images have been stacked in volumes based on a similarity metric that considers the anatomical deformation of lungs, while addressing ambiguities in respiratory phase detection and interpolation of missing data. The resulting images were validated against cine-navigator images and compared to paired 4DCTs in terms of amplitude and period of motion, assessing differences in internal target volume (ITV) margin definition. Results: 4DMR-based motion amplitude was on average within 1.8 mm of that measured in the corresponding 2D cine-navigator images. In our dataset, the 4DCT motion and the 4DMR median amplitude were always within 3.8 mm. The median period was generally close to CT references, although deviations up to 24 % have been observed. These changes were reflected in the ITV, which was generally larger for MRI than for 4DCT (up to 39.7 %). Conclusions: The proposed algorithm for retrospective reconstruction of time-resolved volumetric MR provided quality anatomical images with high temporal resolution for motion modelling and treatment planning. The potential for imaging organ motion variability makes 4DMR a valuable complement to standard 4DCT imaging.

10.
Cancers (Basel) ; 15(21)2023 Nov 04.
Article in English | MEDLINE | ID: mdl-37958460

ABSTRACT

PURPOSE: To assess oncological outcomes, toxicities, quality of life (QoL) and sexual health (SH) of low-grade glioma (LGG) patients treated with pencil-beam scanning proton therapy (PBS-PT). MATERIAL AND METHODS: We retrospectively analyzed 89 patients with LGG (Neurofibromatosis type 1; n = 4 (4.5%) patients) treated with PBS-PT (median dose 54 Gy (RBE)) from 1999 to 2022 at our institution. QoL was prospectively assessed during PBS-PT and yearly during follow-up from 2015 to 2023, while a cross-sectional exploration of SH was conducted in 2023. RESULTS: Most LGGs (n = 58; 65.2%) were CNS WHO grade 2 and approximately half (n = 43; 48.3%) were located in the vicinity of the visual apparatus/thalamus. After a median follow-up of 50.2 months, 24 (27%) patients presented with treatment failures and most of these (n = 17/24; 70.8%) were salvaged. The 4-year overall survival was 89.1%. Only 2 (2.2%) and 1 (1.1%) patients presented with CTCAE grade 4 and 3 late radiation-induced toxicity, respectively. No grade 5 late adverse event was observed. The global health as a domain of QoL remained stable and comparable to the reference values during PBS-PT and for six years thereafter. Sexual satisfaction was comparable to the normative population. CONCLUSIONS: LGG patients treated with PBS-PT achieved excellent long-term survival and tumor control, with exceptionally low rates of high-grade late toxicity, and favorable QoL and SH.

11.
Cancers (Basel) ; 15(12)2023 Jun 07.
Article in English | MEDLINE | ID: mdl-37370709

ABSTRACT

The aim of this study was to assess the clinical outcome, including QoL, of patients with intracranial meningiomas WHO grade 1-3 who were treated with Pencil Beam Scanning Proton Therapy (PBS PT) between 1997 and 2022. Two hundred patients (median age 50.4 years, 70% WHO grade 1) were analyzed. Acute and late side effects were classified according to CTCAE version 5.0. Time to event data were calculated. QoL was assessed descriptively by the EORTC-QLQ-C30 and BN20 questionnaires. With a median follow-up of 65 months (range: 3.8-260.8 months) the 5 year OS was 95.7% and 81.8% for WHO grade 1 and grade 2/3, respectively (p < 0.001). Twenty (10%) local failures were observed. Failures occurred significantly (p < 0.001) more frequent in WHO grade 2 or 3 meningioma (WHO grade 1: n = 7, WHO grade 2/3: n = 13), in patients with multiple meningiomas (p = 0.005), in male patients (p = 0.005), and when PT was initiated not as upfront therapy (p = 0.011). There were no high-grade toxicities in the majority (n = 176; 88%) of patients. QoL was assessed for 83 (41.5%) patients and for those patients PT did not impacted QoL negatively during the follow-up. In summary, we observed very few local recurrences of meningiomas after PBS PT, a stable QoL, and a low rate of high-grade toxicity.

12.
Phys Med Biol ; 68(17)2023 08 11.
Article in English | MEDLINE | ID: mdl-37506707

ABSTRACT

Objective.The treatment of mobile tumours using Pencil Beam Scanning (PBS) has become more prevalent in the last decade. However, to achieve the same beam delivery quality as for static tumours, treatments have to be combined with motion mitigation techniques, not limited but including, breath hold, gating and re-scanning, which typically prolong treatment time. In this article we present a novel method of bi-directional energy modulation and demonstrate our initial experience in improvement of treatment efficiency. Approach.At Paul Scherrer Institute Gantry 2 mobile tumours are treated by combining PBS with gating and volumetric re-scanning (VR), where the target volume is irradiated multiple times. Initial implementation of VR used only descending beam energies, creating a substantial dead time due to the beam-line initialization (ramping) before each re-scan. In 2019 we commissioned an energy meandering strategy that allows us to avoid beam line ramping in-between energy series while maintaining beam delivery quality.Main results.The measured beam parameters difference for both energy sequence are in the order of the typical daily variations: 0.2 mm in beam position and 0.2 mm in range. Using machine log files, we performed point-to-point dose difference calculations between original and new applications where we observed dose differences of less than 2%. After three years of operation employing bi-directional energy modulation, we have analysed the individual beam delivery time for 181 patients and have compared this to simulations of the timing behaviour assuming uni-directional energy sequence application. Depending on treatment complexity, we obtained plan delivery time reductions of up to 55%, with a median time gain of 17% for all types of treatments.Significance. Bi-directional energy modulation can help improving patient treatment efficiency by reducing delivery times especially for complex and specialised irradiations. It could be implemented in many existing facilities without significant additional hardware upgrades.


Subject(s)
Neoplasms , Proton Therapy , Humans , Proton Therapy/methods , Neoplasms/radiotherapy , Motion , Breath Holding , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage
13.
Med Phys ; 50(9): 5828-5841, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37227735

ABSTRACT

BACKGROUND: Experiments with ultra-high dose rates in proton therapy are of increasing interest for potential treatment benefits. The Faraday Cup (FC) is an important detector for the dosimetry of such ultra-high dose rate beams. So far, there is no consensus on the optimal design of a FC, or on the influence of beam properties and magnetic fields on shielding of the FC from secondary charged particles. PURPOSE: To perform detailed Monte Carlo simulations of a Faraday cup to identify and quantify all the charge contributions from primary protons and secondary particles that modify the efficiency of the FC response as a function of a magnetic field employed to improve the detector's reading. METHODS: In this paper, a Monte Carlo (MC) approach was used to investigate the Paul Scherrer Institute (PSI) FC and quantify contributions of charged particles to its signal for beam energies of 70, 150, and 228 MeV and magnetic fields between 0 and 25 mT. Finally, we compared our MC simulations to measurements of the response of the PSI FC. RESULTS: For maximum magnetic fields, the efficiency (signal of the FC normalized to charged delivered by protons) of the PSI FC varied between 99.97% and 100.22% for the lowest and highest beam energy. We have shown that this beam energy-dependence is mainly caused by contributions of secondary charged particles, which cannot be fully suppressed by the magnetic field. Additionally, it has been demonstrated that these contributions persist, making the FC efficiency beam energy dependent for fields up to 250 mT, posing inevitable limits on the accuracy of FC measurements if not corrected. In particular, we have identified a so far unreported loss of electrons via the outer surfaces of the absorber block and show the energy distributions of secondary electrons ejected from the vacuum window (VW) (up to several hundred keV), together with electrons ejected from the absorber block (up to several MeV). Even though, in general, simulations and measurements were well in agreement, the limitation of the current MC calculations to produce secondary electrons below 990 eV posed a limit in the efficiency simulations in the absence of a magnetic field as compared to the experimental data. CONCLUSION: TOPAS-based MC simulations allowed to identify various and previously unreported contributions to the FC signal, which are likely to be present in other FC designs. Estimating the beam energy dependence of the PSI FC for additional beam energies could allow for the implementation of an energy-dependent correction factor to the signal. Dose estimates, based on accurate measurements of the number of delivered protons, provided a valid instrument to challenge the dose determined by reference ionization chambers, not only at ultra-high dose rates but also at conventional dose rates.


Subject(s)
Proton Therapy , Protons , Radiometry , Monte Carlo Method , Magnetic Fields , Radiotherapy Dosage
14.
Phys Med Biol ; 68(19)2023 09 22.
Article in English | MEDLINE | ID: mdl-37652055

ABSTRACT

Objective. Investigating the aspects of proton beam delivery to track organ motion with pencil beam scanning therapy. Considering current systems as a reference, specify requirements for next-generation units aiming at real-time image-guided treatments.Approach. Proton treatments for six non-small cell lung cancer (NSCLC) patients were simulated using repeated 4DCTs to model respiratory motion variability. Energy corrections required for this treatment site were evaluated for different approaches to tumour tracking, focusing on the potential for energy adjustment within beamline momentum acceptance (dp/p). A respiration-synchronised tracking, taking into account realistic machine delivery limits, was compared to ideal tracking scenarios, in which unconstrained energy corrections are possible. Rescanning and the use of multiple fields to mitigate residual interplay effects and dose degradation have also been investigated.Main results. Energy correction requirements increased with motion amplitudes, for all patients and tracking scenarios. Higher dose degradation was found for larger motion amplitudes, rescanning has beneficial effects and helped to improve dosimetry metrics for the investigated limited dp/pof 1.2% (realistic) and 2.4%. The median differences between ideal and respiratory-synchronised tracking show minimal discrepancies, 1% and 5% respectively for dose coverage (CTV V95) and homogeneity (D5-D95). Multiple-field planning improves D5-D95 up to 50% in the most extreme cases while it does not show a significant effect on V95.Significance. This work shows the potential of implementing tumour tracking in current proton therapy units and outlines design requirements for future developments. Energy regulation within momentum acceptance was investigated to tracking tumour motion with respiratory-synchronisation, achieving results in line with the performance of ideal tracking scenarios. ±5% Δp/p would allow to compensate for all range offsets in our NSCLC patient cohort, including breathing variability. However, the realistic momentum of 1.2% dp/prepresentative of existing medical units limitations, has been shown to preserve plan quality.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Proton Therapy , Humans , Lung Neoplasms/radiotherapy , Carcinoma, Non-Small-Cell Lung/radiotherapy , Protons , Respiratory Rate
15.
Phys Imaging Radiat Oncol ; 28: 100517, 2023 Oct.
Article in English | MEDLINE | ID: mdl-38026085

ABSTRACT

Background and purpose: An optical tracking system for high-precision measurement of eye position and orientation during proton irradiation of intraocular tumors was designed. The system performed three-dimensional (3D) topography of the anterior eye segment using fringe pattern analysis based on Fourier Transform Method (FTM). Materials and methods: The system consisted of four optical cameras and two projectors. The design and modifications to the FTM pipeline were optimized for the realization of a reliable measurement system. Of note, phase-to-physical coordinate mapping was achieved through the combination of stereo triangulation and fringe pattern analysis. A comprehensive pre-clinical validation was carried out. Then, the system was set to acquire the eye surface of patients undergoing proton therapy. Topographies of the eye were compared to manual contouring on MRI. Results: Pre-clinical results demonstrated that 3D topography could achieve sub-millimetric accuracy (median:0.58 mm) and precision (RMSE:0.61 mm) in the clinical setup. The absolute median discrepancy between MRI and FTM-based anterior eye segment surface reconstruction was 0.43 mm (IQR:0.65 mm). Conclusions: The system complied with the requirement of precision and accuracy for image guidance in ocular proton therapy radiation and is expected to be clinically tested soon to evaluate its performance against the current standard.

16.
Phys Med Biol ; 2023 Jun 09.
Article in English | MEDLINE | ID: mdl-37295440

ABSTRACT

OBJECTIVE: The Jagiellonian PET (J-PET) technology, based on plastic scintillators, has been proposed as a cost effective tool for detecting range deviations during proton therapy. This study investigates the feasibility of using J-PET for range monitoring by means of a detailed Monte Carlo simulation study of 95 patients who underwent proton therapy at the Cyclotron Centre Bronowice (CCB) in Krakow, Poland. Approach: Discrepancies between prescribed and delivered treatments were artificially introduced in the simulations by means of shifts in patient positioning and in the Hounsfield unit to the relative proton stopping power calibration curve. A dual-layer, cylindrical J-PET geometry was simulated in an in-room monitoring scenario and a triple-layer, dual-head geometry in an in-beam protocol. The distribution of range shifts in reconstructed PET activity was visualised in the beam's eye view. Linear prediction models were constructed from all patients in the cohort, using the mean shift in reconstructed PET activity as a predictor of the mean proton range deviation. Main results: Maps of deviations in the range of reconstructed PET distributions showed agreement with those of deviations in dose range in most patients. The linear prediction model showed a good fit, with coefficient of determination r^2 = 0.84 (in-room) and 0.75 (in-beam). Residual standard error was below 1 mm: 0.33 mm (in-room) and 0.23 mm (in-beam). Significance: The precision of the proposed prediction models shows the sensitivity of the proposed J-PET scanners to shifts in proton range for a wide range of clinical treatment plans. Furthermore, it motivates the use of such models as a tool for predicting proton range deviations and opens up new prospects for investigations into the use of intra-treatment PET images for predicting clinical metrics that aid in the assessment of the quality of delivered treatment. .

17.
Phys Med Biol ; 67(22)2022 Nov 07.
Article in English | MEDLINE | ID: mdl-36279860

ABSTRACT

Objective.In pencil beam scanning particle therapy, a short treatment delivery time is paramount for the efficient treatment of moving targets with motion mitigation techniques (such as breath-hold, rescanning, and gating). Energy and spot position change time are limiting factors in reducing treatment time. In this study, we designed a universal and dynamic energy modulator (ridge filter, RF) to broaden the Bragg peak, to reduce the number of energies and spots required to cover the target volume, thus lowering the treatment time.Approach. Our RF unit comprises two identical RFs placed just before the isocenter. Both RFs move relative to each other, changing the Bragg peak's characteristics dynamically. We simulated different Bragg peak shapes with the RF in Monte Carlo simulation code (TOPAS) and validated them experimentally. We then delivered single-field plans with 1 Gy/fraction to different geometrical targets in water, to measure the dose delivery time using the RF and compare it with the clinical settings.Main results.Aligning the RFs in different positions produces different broadening in the Bragg peak; we achieved a maximum broadening of 2.5 cm. With RF we reduced the number of energies in a field by more than 60%, and the dose delivery time by 50%, for all geometrical targets investigated, without compromising the dose distribution transverse and distal fall-off.Significance. Our novel universal and dynamic RF allows for the adaptation of the Bragg peak broadening for a spot and/or energy layer based on the requirement of dose shaping in the target volume. It significantly reduces the number of energy layers and spots to cover the target volume, and thus the treatment time. This RF design is ideal for ultra-fast treatment delivery within a single breath-hold (5-10 s), efficient delivery of motion mitigation techniques, and small animal irradiation with ultra-high dose rates (FLASH).


Subject(s)
Proton Therapy , Radiotherapy Dosage , Proton Therapy/methods , Monte Carlo Method , Radiotherapy Planning, Computer-Assisted/methods , Breath Holding
18.
Med Phys ; 49(8): 5374-5386, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35561077

ABSTRACT

PURPOSE: Advanced non-small cell lung cancer (NSCLC) is still a challenging indication for conventional photon radiotherapy. Proton therapy has the potential to improve outcomes, but proton treatment slots remain a limited resource despite an increasing number of proton therapy facilities. This work investigates the potential benefits of optimally combined proton-photon therapy delivered using a fixed horizontal proton beam line in combination with a photon Linac, which could increase accessibility to proton therapy for such a patient cohort. MATERIALS AND METHODS: A treatment planning study has been conducted on a patient cohort of seven advanced NSCLC patients. Each patient had a planning computed tomography scan (CT) and multiple repeated CTs from three different days and for different breath-holds on each day. Treatment plans for combined proton-photon therapy (CPPT) were calculated for individual patients by optimizing the combined cumulative dose on the initial planning CT only (non-adapted) as well as on each daily CT respectively (adapted). The impact of inter-fractional changes and/or breath-hold variability was then assessed on the repeat breath-hold CTs. Results were compared to plans for IMRT or IMPT alone, as well as against combined treatments assuming a proton gantry. Plan quality was assessed in terms of dosimetric, robustness and NTCP metrics. RESULTS: Combined treatment plans improved plan quality compared to IMRT treatments, especially in regard to reductions of low and medium doses to organs at risk (OARs), which translated into lower NTCP estimates for three side effects. For most patients, combined treatments achieved results close to IMPT-only plans. Inter-fractional changes impact mainly the target coverage of combined and IMPT treatments, while OARs doses were less affected by these changes. With plan adaptation however, target coverage of combined treatments remained high even when taking variability between breath-holds into account. CONCLUSIONS: Optimally combined proton-photon plans improve treatment plan quality compared to IMRT only, potentially reducing the risk of toxicity while also allowing to potentially increase accessibility to proton therapy for NSCLC patients.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Proton Therapy , Radiotherapy, Intensity-Modulated , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/radiotherapy , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Organs at Risk , Proton Therapy/methods , Protons , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
19.
Med Phys ; 49(3): 1417-1431, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35041207

ABSTRACT

PURPOSE: Energy changes in pencil beam scanning proton therapy can be a limiting factor in delivery time, hence, limiting patient throughput and the effectiveness of motion mitigation techniques requiring fast irradiation. In this study, we investigate the feasibility of performing fast and continuous energy modulation within the momentum acceptance of a clinical beamline for proton therapy. METHODS: The alternative use of a local beam degrader at the gantry coupling point has been compared with a more common upstream regulation. Focusing on clinically relevant parameters, a complete beam properties characterization has been carried out. In particular, the acquired empirical data allowed to model and parametrize the errors in range and beam current to deliver clinical treatment plans. RESULTS: For both options, the local and upstream degrader, depth-dose curves measured in water for off-momentum beams were only marginally distorted (γ(1%, 1 mm) > 90%) and the errors in the spot position were within the clinical tolerance, even though increasing at the boundaries of the investigated scan range. The impact on the beam size was limited for the upstream degrader, while dedicated strategies could be required to tackle the beam broadening through the local degrader. Range correction models were investigated for the upstream regulation. The impaired beam transport required a dedicated strategy for fine range control and compensation of beam intensity losses. Our current parameterization based on empirical data allowed energy modulation within acceptance with range errors (median 0.05 mm) and transmission (median -14%) compatible with clinical operation and remarkably low average 27 ms dead time for small energy changes. The technique, tested for the delivery of a skull glioma treatment, resulted in high gamma pass rates at 1%, 1 mm compared to conventional deliveries in experimental measurements with about 45% reduction of the energy switching time when regulation could be performed within acceptance. CONCLUSIONS: Fast energy modulation within beamline acceptance has potential for clinical applications and, when realized with an upstream degrader, does not require modification in the beamline hardware, therefore, being potentially applicable in any running facility. Centers with slow energy switching time can particularly profit from such a technique for reducing dead time during treatment delivery.


Subject(s)
Proton Therapy , Humans , Proton Therapy/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Synchrotrons , Water
20.
Curr Oncol ; 29(4): 2364-2375, 2022 03 28.
Article in English | MEDLINE | ID: mdl-35448165

ABSTRACT

BACKGROUND: Chordoma are rare tumors of the axial skeleton. The treatment gold standard is surgery, followed by particle radiotherapy. Total resection is usually not achievable in skull base chordoma (SBC) and high recurrence rates are reported. Ectopic recurrence as a first sign of treatment failure is considered rare. Favorable sites of these ectopic recurrences remain unknown. METHODS: Five out of 16 SBC patients treated with proton therapy and surgical resection developed ectopic recurrence as a first sign of treatment failure were critically analyzed regarding prior surgery, radiotherapy, and recurrences at follow-up imaging. RESULTS: Eighteen recurrences were defined in five patients. A total of 31 surgeries were performed for primary tumors and recurrences. Seventeen out of eighteen (94%) ectopic recurrences could be related to prior surgical tracts, outside the therapeutic radiation dose. Follow-up imaging showed that tumor recurrence was difficult to distinguish from radiation necrosis and anatomical changes due to surgery. CONCLUSIONS: In our cohort, we found uncommon ectopic recurrences in the surgical tract. Our theory is that these recurrences are due to microscopic tumor spill during surgery. These cells did not receive a therapeutic radiation dose. Advances in surgical possibilities and adjusted radiotherapy target volumes might improve local control and survival.


Subject(s)
Chordoma , Head and Neck Neoplasms , Proton Therapy , Skull Base Neoplasms , Chordoma/radiotherapy , Chordoma/surgery , Humans , Recurrence , Skull Base , Skull Base Neoplasms/radiotherapy , Skull Base Neoplasms/surgery
SELECTION OF CITATIONS
SEARCH DETAIL