ABSTRACT
BACKGROUND: Malignant pleural effusion is mostly a complication of advanced malignant tumors. However, the cancer markers such as carbohydrate antigen 125 (CA 125), carbohydrate antigen 15-3 (CA 15-3), carbohydrate antigen 19-9 (CA 19-9), and cytokeratin fragment 21-1 (CYFRA 21-1) have low sensitivity and organ specificity for detecting malignant pleural effusion. RESEARCH QUESTION: Is IR808@MnO nano-near infrared fluorescent dye worthy for the diagnosis in differentiating benign and malignant pleural effusions. STUDY DESIGN AND METHODS: This experiment was carried out to design and characterize the materials for in vitro validation of the new dye in malignant tumor cells in the A549 cell line and in patients with adenocarcinoma pleural effusion. The dye was verified to possess tumor- specific targeting capabilities. Subsequently, a prospective hospital-based observational study was conducted, enrolling 106 patients and excluding 28 patients with unknown diagnoses. All patients underwent histopathological analysis of thoracoscopic biopsies, exfoliative cytological analysis of pleural fluid, and analysis involving the new dye. Statistical analyses were performed using Microsoft Excel, GraphPad Prism, and the R language. RESULTS: The size of IR808@MnO was 136.8 ± 2.9 nm, with peak emission at 808 nm, and it has near-infrared fluorescence properties. Notably, there was a significant difference in fluorescence values between benign and malignant cell lines (p < 0.0001). The malignant cell lines tested comprised CL1-5, A549, MDA-MB-468, U-87MG, MKN-7, and Hela, while benign cell lines were BEAS-2B, HUVEC, HSF, and VE. The most effective duration of action was identified as 30 min at a concentration of 5 µl. This optimal duration of action and concentration were consistent in patients with lung adenocarcinoma accompanied by pleural effusion and 5 µl. Of the 106 patients examined, 28 remained undiagnosed, 39 were diagnosed with malignant pleural effusions, and the remaining 39 with benign pleural effusions. Employing the new IR808@MnO staining method, the sensitivity stood at 74.4%, specificity at 79.5%, a positive predictive value of 69.2%, and a negative predictive value of 82.1%. The area under the ROC curve was recorded as 0.762 (95% CI: 0.652-0.872). The confusion matrix revealed a positive predictive value of 75.7%, a negative predictive value of 75.6%, a false positive rate of 22.5%, and a false negative rate of 26.3%. INTERPRETATION: The IR808@MnO fluorescent probe represents an efficient, sensitive, and user-friendly diagnostic tool for detecting malignant pleural fluid, underscoring its significant potential for clinical adoption.
Subject(s)
Lung Neoplasms , Pleural Effusion, Malignant , Pleural Effusion , Humans , Pleural Effusion, Malignant/diagnosis , Fluorescent Dyes , Prospective Studies , Pleural Effusion/diagnostic imaging , CarbohydratesABSTRACT
According to the World Health Organization (WHO), the COVID-19 pandemic has been declared as a priority disease. Some patients with COVID-19 had symptoms of multiple organ failure and death. The published articles on COVID-19 infection were reviewed. The origin of SARS-CoV-2 is still not completely established. Person-to-person transmission via droplets, probable aerosols, or close contact is considered as the main mode of transmission. With increased mortality due to SARS-CoV-2, valuable clinical indicators or treatments should be further identified and summarized. CT scanning plays an important role in the diagnosis and evaluation of COVID-19 in asymptomatic patients or those with initially negative RT-PCR results. No specific antiviral therapy is recommended, except the main supportive treatments, and effective measures should be taken into consideration to protect important organs and prevent the development of acute respiratory distress syndrome (ARDS) in patients with severe infection.