Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 62
Filter
1.
Proc Natl Acad Sci U S A ; 118(49)2021 12 07.
Article in English | MEDLINE | ID: mdl-34845021

ABSTRACT

During metamorphosis, the wings of a butterfly sprout hundreds of thousands of scales with intricate microstructures and nano-structures that determine the wings' optical appearance, wetting characteristics, thermodynamic properties, and aerodynamic behavior. Although the functional characteristics of scales are well known and prove desirable in various applications, the dynamic processes and temporal coordination required to sculpt the scales' many structural features remain poorly understood. Current knowledge of scale growth is primarily gained from ex vivo studies of fixed scale cells at discrete time points; to fully understand scale formation, it is critical to characterize the time-dependent morphological changes throughout their development. Here, we report the continuous, in vivo, label-free imaging of growing scale cells of Vanessa cardui using speckle-correlation reflection phase microscopy. By capturing time-resolved volumetric tissue data together with nanoscale surface height information, we establish a morphological timeline of wing scale formation and gain quantitative insights into the underlying processes involved in scale cell patterning and growth. We identify early differences in the patterning of cover and ground scales on the young wing and quantify geometrical parameters of growing scale features, which suggest that surface growth is critical to structure formation. Our quantitative, time-resolved in vivo imaging of butterfly scale development provides the foundation for decoding the processes and biomechanical principles involved in the formation of functional structures in biological materials.


Subject(s)
Animal Scales/anatomy & histology , Animal Scales/ultrastructure , Wings, Animal/anatomy & histology , Animal Scales/physiology , Animals , Butterflies/anatomy & histology , Butterflies/metabolism , Color , Lepidoptera/anatomy & histology , Lepidoptera/metabolism , Metamorphosis, Biological , Morphogenesis , Pigmentation , Wings, Animal/physiology , Wings, Animal/ultrastructure
2.
Proc Natl Acad Sci U S A ; 118(35)2021 08 31.
Article in English | MEDLINE | ID: mdl-34446562

ABSTRACT

Lyotropic chromonic liquid crystals are water-based materials composed of self-assembled cylindrical aggregates. Their behavior under flow is poorly understood, and quantitatively resolving the optical retardance of the flowing liquid crystal has so far been limited by the imaging speed of current polarization-resolved imaging techniques. Here, we employ a single-shot quantitative polarization imaging method, termed polarized shearing interference microscopy, to quantify the spatial distribution and the dynamics of the structures emerging in nematic disodium cromoglycate solutions in a microfluidic channel. We show that pure-twist disclination loops nucleate in the bulk flow over a range of shear rates. These loops are elongated in the flow direction and exhibit a constant aspect ratio that is governed by the nonnegligible splay-bend anisotropy at the loop boundary. The size of the loops is set by the balance between nucleation forces and annihilation forces acting on the disclination. The fluctuations of the pure-twist disclination loops reflect the tumbling character of nematic disodium cromoglycate. Our study, including experiment, simulation, and scaling analysis, provides a comprehensive understanding of the structure and dynamics of pressure-driven lyotropic chromonic liquid crystals and might open new routes for using these materials to control assembly and flow of biological systems or particles in microfluidic devices.


Subject(s)
Anisotropy , Computer Simulation , Cromolyn Sodium/chemistry , Liquid Crystals/chemistry , Phase Transition , Pressure , Models, Chemical
3.
Methods ; 136: 35-39, 2018 03 01.
Article in English | MEDLINE | ID: mdl-29079485

ABSTRACT

Interferometric microscopy (IM) can provide complex field information of the biological samples with high spatial and temporal resolution with virtually no photodamage. Measuring wavelength-dependent information in particular has a wide range of applications from cell and tissue refractometry to the cellular biophysical measurements. IM measurements at multiple wavelengths are typically associated with a loss in temporal resolution, field of view, stability, sensitivity, and may involve using expensive equipment such as tunable filters or spatial light modulators. Here, we present a novel and simple design for an interferometric microscope that provides single-shot off-axis interferometric measurements at two wavelengths by encoding the two spectral images at two orthogonal spatial frequencies that allows clean separation of information in the Fourier space with no resolution loss. We demonstrated accurate simultaneous quantification of polystyrene bead refractive indices at two wavelengths.


Subject(s)
Image Enhancement/methods , Microscopy, Interference/trends , Refractometry/methods , Equipment Design , Light , Microscopy, Interference/methods
4.
Proc Natl Acad Sci U S A ; 113(34): 9527-32, 2016 08 23.
Article in English | MEDLINE | ID: mdl-27512047

ABSTRACT

Hydroxyurea (HU) has been used clinically to reduce the frequency of painful crisis and the need for blood transfusion in sickle cell disease (SCD) patients. However, the mechanisms underlying such beneficial effects of HU treatment are still not fully understood. Studies have indicated a weak correlation between clinical outcome and molecular markers, and the scientific quest to develop companion biophysical markers have mostly targeted studies of blood properties under hypoxia. Using a common-path interferometric technique, we measure biomechanical and morphological properties of individual red blood cells in SCD patients as a function of cell density, and investigate the correlation of these biophysical properties with drug intake as well as other clinically measured parameters. Our results show that patient-specific HU effects on the cellular biophysical properties are detectable at normoxia, and that these properties are strongly correlated with the clinically measured mean cellular volume rather than fetal hemoglobin level.


Subject(s)
Anemia, Sickle Cell/drug therapy , Antisickling Agents/pharmacology , Erythrocytes/drug effects , Hydroxyurea/pharmacology , Anemia, Sickle Cell/blood , Anemia, Sickle Cell/pathology , Biomarkers/blood , Blood Cell Count , Blood Transfusion , Erythrocyte Deformability , Erythrocytes/metabolism , Erythrocytes/pathology , Fetal Hemoglobin , Humans , Microscopy, Interference , Oxygen/pharmacology
5.
Opt Express ; 26(1): 428-437, 2018 Jan 08.
Article in English | MEDLINE | ID: mdl-29328319

ABSTRACT

Optical diffraction tomography (ODT) is an emerging microscopy technique for three-dimensional (3D) refractive index (RI) mapping of transparent specimens. Recently, the digital micromirror device (DMD) based scheme for angle-controlled plane wave illumination has been proposed to improve the imaging speed and stability of ODT. However, undesired diffraction noise always exists in the reported DMD-based illumination scheme, which leads to a limited contrast ratio of the measurement fringe and hence inaccurate RI mapping. Here we present a novel spatial filtering method, based on a second DMD, to dynamically remove the diffraction noise. The reported results illustrate significantly enhanced image quality of the obtained interferograms and the subsequently derived phase maps. And moreover, with this method, we demonstrate mapping of 3D RI distribution of polystyrene beads as well as biological cells with high accuracy. Importantly, with the proper hardware configuration, our method does not compromise the 3D imaging speed advantage promised by the DMD-based illumination scheme. Specifically, we have been able to successfully obtain interferograms at over 1 kHz speed, which is critical for potential high-throughput label-free 3D image cytometry applications.

6.
Opt Express ; 26(21): 26858-26865, 2018 Oct 15.
Article in English | MEDLINE | ID: mdl-30469763

ABSTRACT

We propose and experimentally demonstrate a method of polarization-sensitive quantitative phase imaging using two photodetectors and a digital micromirror device. Instead of recording wide-field interference patterns, finding the modulation patterns maximizing focused intensities in terms of the polarization states enables polarization-dependent quantitative phase imaging without the need for a reference beam and an image sensor. The feasibility of the present method is experimentally validated by reconstructing Jones matrices of several samples including a polystyrene microsphere, a maize starch granule, and a mouse retinal nerve fiber layer. Since the present method is simple and sufficiently general, we expect that it may offer solutions for quantitative phase imaging of birefringent materials.

7.
Cytometry A ; 91(5): 450-459, 2017 05.
Article in English | MEDLINE | ID: mdl-28444998

ABSTRACT

A major challenge in cellular analysis is the phenotypic characterization of large cell populations within a short period of time. Among various parameters for cell characterization, the cell dry mass is often used to describe cell size but is difficult to be measured directly with traditional techniques. Here, we propose an interferometric approach based on line-focused beam illumination for high-content precision dry mass measurements of adherent cells in a non-invasive fashion-we call it quantitative phase cytometry (QPC). Besides dry mass, abundant cellular morphological features such as projected area, sphericity, and phase skewness can be readily extracted from the QPC interferometric data. To validate the utility of our technique, we demonstrate characterizing a large population of ∼104 HeLa cells. Our reported QPC system is envisioned as a promising quantitative tool for label-free characterization of a large cell count at single cell resolution. © 2017 International Society for Advancement of Cytometry.


Subject(s)
Cell Count/methods , Flow Cytometry/methods , Image Cytometry/methods , Image Processing, Computer-Assisted/methods , Cell Size , HeLa Cells , Humans
8.
Opt Express ; 25(1): 130-143, 2017 Jan 09.
Article in English | MEDLINE | ID: mdl-28085800

ABSTRACT

Unlike most optical coherence microscopy (OCM) systems, dynamic speckle-field interferometric microscopy (DSIM) achieves depth sectioning through the spatial-coherence gating effect. Under high numerical aperture (NA) speckle-field illumination, our previous experiments have demonstrated less than 1 µm depth resolution in reflection-mode DSIM, while doubling the diffraction limited resolution as under structured illumination. However, there has not been a physical model to rigorously describe the speckle imaging process, in particular explaining the sectioning effect under high illumination and imaging NA settings in DSIM. In this paper, we develop such a model based on the diffraction tomography theory and the speckle statistics. Using this model, we calculate the system response function, which is used to further obtain the depth resolution limit in reflection-mode DSIM. Theoretically calculated depth resolution limit is in an excellent agreement with experiment results. We envision that our physical model will not only help in understanding the imaging process in DSIM, but also enable better designing such systems for depth-resolved measurements in biological cells and tissues.

9.
Opt Lett ; 42(7): 1448-1451, 2017 Apr 01.
Article in English | MEDLINE | ID: mdl-28362789

ABSTRACT

We propose a novel common-path quantitative phase imaging (QPI) method based on a digital micromirror device (DMD). The DMD is placed in a plane conjugate to the objective back-aperture plane for the purpose of generating two plane waves that illuminate the sample. A pinhole is used in the detection arm to filter one of the beams after sample to create a reference beam. Additionally, a transmission-type liquid crystal device, placed at the objective back-aperture plane, eliminates the specular reflection noise arising from all the "off" state DMD micromirrors, which is common in all DMD-based illuminations. We have demonstrated high sensitivity QPI, which has a measured spatial and temporal noise of 4.92 nm and 2.16 nm, respectively. Experiments with calibrated polystyrene beads illustrate the desired phase measurement accuracy. In addition, we have measured the dynamic height maps of red blood cell membrane fluctuations, showing the efficacy of the proposed system for live cell imaging. Most importantly, the DMD grants the system convenience in varying the interference fringe period on the camera to easily satisfy the pixel sampling conditions. This feature also alleviates the pinhole alignment complexity. We envision that the proposed DMD-based common-path QPI system will allow for system miniaturization and automation for a broader adaption.

10.
J Opt Soc Am B ; 34(5): B64-B77, 2017.
Article in English | MEDLINE | ID: mdl-29386746

ABSTRACT

Tomographic phase microscopy (TPM) is an emerging optical microscopic technique for bioimaging. TPM uses digital holographic measurements of complex scattered fields to reconstruct three-dimensional refractive index (RI) maps of cells with diffraction-limited resolution by solving inverse scattering problems. In this paper, we review the developments of TPM from the fundamental physics to its applications in bioimaging. We first provide a comprehensive description of the tomographic reconstruction physical models used in TPM. The RI map reconstruction algorithms and various regularization methods are discussed. Selected TPM applications for cellular imaging, particularly in hematology, are reviewed. Finally, we examine the limitations of current TPM systems, propose future solutions, and envision promising directions in biomedical research.

11.
Opt Lett ; 41(7): 1656-9, 2016 Apr 01.
Article in English | MEDLINE | ID: mdl-27192311

ABSTRACT

Sensitivity of the amplitude and phase measurements in interferometric microscopy is influenced by factors such as instrument design and environmental interferences. Through development of a theoretical framework followed by experimental validation, we show photon shot noise is often the limiting factor in interferometric microscopy measurements. Thereafter, we demonstrate how a state-of-the-art camera with million-level electrons full well capacity can significantly reduce shot noise contribution resulting in a stability of optical path length down to a few picometers even in a near-common-path interferometer.

12.
Proc Natl Acad Sci U S A ; 110(41): 16687-92, 2013 Oct 08.
Article in English | MEDLINE | ID: mdl-24065823

ABSTRACT

The coupling of the rate of cell growth to the rate of cell division determines cell size, a defining characteristic that is central to cell function and, ultimately, to tissue architecture. The physiology of size homeostasis has fascinated generations of biologists, but the mechanism, challenged by experimental limitations, remains largely unknown. In this paper, we propose a unique optical method that can measure the dry mass of thick live cells as accurately as that for thin cells with high computational efficiency. With this technique, we quantify, with unprecedented accuracy, the asymmetry of division in lymphoblasts and epithelial cells. We can then use the Collins-Richmond model of conservation to compute the relationship between growth rate and cell mass. In attached epithelial cells, we find that due to the asymmetry in cell division and size-dependent growth rate, there is active regulation of cell size. Thus, like nonadherent cells, size homeostasis requires feedback control.


Subject(s)
Cell Enlargement , Homeostasis/physiology , Microscopy, Phase-Contrast/methods , Animals , Cell Adhesion/physiology , Cells, Cultured , Holography/methods , Lasers , Mice , Refractometry
13.
Opt Express ; 23(15): 19752-62, 2015 Jul 27.
Article in English | MEDLINE | ID: mdl-26367632

ABSTRACT

We have developed an interferometric optical microscope that provides three-dimensional refractive index map of a specimen by scanning the color of three illumination beams. Our design of the interferometer allows for simultaneous measurement of the scattered fields (both amplitude and phase) of such a complex input beam. By obviating the need for mechanical scanning of the illumination beam or detection objective lens; the proposed method can increase the speed of the optical tomography by orders of magnitude. We demonstrate our method using polystyrene beads of known refractive index value and live cells.


Subject(s)
Tomography, Optical/methods , Animals , Color , Fourier Analysis , Hematopoietic Stem Cells/cytology , Humans , Imaging, Three-Dimensional , Microscopy , Refractometry
14.
Opt Express ; 23(21): 26999-7010, 2015 Oct 19.
Article in English | MEDLINE | ID: mdl-26480361

ABSTRACT

We report a novel approach to Fourier ptychographic microscopy (FPM) by using a digital micromirror device (DMD) and a coherent laser source (532 nm) for generating spatially modulated sample illumination. Previously demonstrated FPM systems are all based on partially-coherent illumination, which offers limited throughput due to insufficient brightness. Our FPM employs a high power coherent laser source to enable shot-noise limited high-speed imaging. For the first time, a digital micromirror device (DMD), imaged onto the back focal plane of the illumination objective, is used to generate spatially modulated sample illumination field for ptychography. By coding the on/off states of the micromirrors, the illumination plane wave angle can be varied at speeds more than 4 kHz. A set of intensity images, resulting from different oblique illuminations, are used to numerically reconstruct one high-resolution image without obvious laser speckle. Experiments were conducted using a USAF resolution target and a fiber sample, demonstrating high-resolution imaging capability of our system. We envision that our approach, if combined with a coded-aperture compressive-sensing algorithm, will further improve the imaging speed in DMD-based FPM systems.


Subject(s)
Image Enhancement/instrumentation , Lasers , Lenses , Lighting/instrumentation , Microscopy/instrumentation , Signal Processing, Computer-Assisted/instrumentation , Equipment Design , Equipment Failure Analysis , Fourier Analysis , Miniaturization , Reproducibility of Results , Sensitivity and Specificity
15.
Opt Lett ; 39(20): 6062-5, 2014 Oct 15.
Article in English | MEDLINE | ID: mdl-25361156

ABSTRACT

We demonstrate a quantitative reflection-phase microscope based on time-varying speckle-field illumination. Due to the short spatial coherence length of the speckle field, the proposed imaging system features superior lateral resolution, 520 nm, as well as high-depth selectivity, 1.03 µm. Off-axis interferometric detection enables wide-field and single-shot imaging appropriate for high-speed measurements. In addition, the measured phase sensitivity of this method, which is the smallest measurable axial motion, is more than 40 times higher than that available using a transmission system. We demonstrate the utility of our method by successfully distinguishing the motion of the top surface from that of the bottom in red blood cells. The proposed method will be useful for studying membrane dynamics in complex eukaryotic cells.


Subject(s)
Light , Microscopy/methods , Erythrocytes/cytology , Polystyrenes/chemistry
16.
Opt Lett ; 39(24): 6935-8, 2014 Dec 15.
Article in English | MEDLINE | ID: mdl-25503034

ABSTRACT

A simple and practical method to measure three-dimensional (3-D) refractive index (RI) distributions of biological cells is presented. A common-path self-reference interferometry consisting of a compact set of polarizers is attached to a conventional inverted microscope equipped with a beam scanning unit, which can precisely measure multiple 2-D holograms of a sample with high phase stability for various illumination angles, from which accurate 3-D optical diffraction tomograms of the sample can be reconstructed. 3-D RI tomograms of nonbiological samples such as polystyrene microspheres, as well as biological samples including human red blood cells and breast cancer cells, are presented.


Subject(s)
Tomography, Optical/methods , Cell Line, Tumor , Erythrocytes/cytology , Humans , Microscopy , Polystyrenes
17.
Phys Chem Chem Phys ; 16(48): 27074-7, 2014 Dec 28.
Article in English | MEDLINE | ID: mdl-25384880

ABSTRACT

By using the depth selective imaging method, we studied the UV induced change in a photomobile liquid crystalline polymer film. With 1 µm depth resolution, each slice inside the film was selectively observed. A network-like structure mixed with the ordered and disordered regions of molecules in the middle of the film, and a rubbed polymer layer at the bottom of the film were observed. In each slice of the film, the phase change induced by UV light was observed strongly dependent on the director direction, which indicates the ordering change of the liquid crystalline molecules in the director direction. It took several tens of seconds for the ordering change caused by the collaborative interaction between the molecules. Furthermore, it was suggested that the UV induced change travelled from the bottom layer to the middle layer on the micron order.


Subject(s)
Liquid Crystals/chemistry , Polymers/chemistry , Anisotropy , Spectrum Analysis, Raman , Ultraviolet Rays
18.
Biomed Opt Express ; 15(2): 973-990, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38404316

ABSTRACT

Angularly resolved light scattering (ALS) has become a useful tool for assessing the size and refractive index of biological scatterers at cellular and organelle length scales. Sizing organelle populations with ALS relies on Mie scattering theory models, which require significant assumptions about the object, including spherical scatterers and a homogeneous medium. These assumptions may incur greater error at the single cell level, where there are fewer scatterers to be averaged over. We investigate the validity of these assumptions using 3D refractive index (RI) tomograms measured via optical diffraction tomography (ODT). We compute the angular scattering on digitally manipulated tomograms with increasingly strong model assumptions, including RI-matched immersion media, homogeneous cytosol, and spherical organelles. We also compare the tomogram-computed angular scattering to experimental measurements of angular scattering from the same cells to ensure that the ODT-based approach accurately models angular scattering. We show that enforced RI-matching with the immersion medium and a homogeneous cytosol significantly affects the angular scattering intensity shape, suggesting that these assumptions can reduce the accuracy of size distribution estimates.

19.
Phys Rev Lett ; 111(24): 243901, 2013 Dec 13.
Article in English | MEDLINE | ID: mdl-24483661

ABSTRACT

Multiple scatterings occurring in a turbid medium attenuate the intensity of propagating waves. Here, we propose a method to efficiently deliver light energy to the desired target depth in a scattering medium. We measure the time-resolved reflection matrix of a scattering medium using coherent time-gated detection. From this matrix, we derive and experimentally implement an incident wave pattern that optimizes the detected signal corresponding to a specific arrival time. This leads to enhanced light delivery at the target depth. The proposed method will lay a foundation for efficient phototherapy and deep-tissue in vivo imaging in the near future.


Subject(s)
Electromagnetic Radiation , Light , Nephelometry and Turbidimetry/methods , Scattering, Radiation , Nephelometry and Turbidimetry/instrumentation
20.
Light Sci Appl ; 12(1): 200, 2023 Aug 22.
Article in English | MEDLINE | ID: mdl-37607903

ABSTRACT

Resolving three-dimensional morphological features in thick specimens remains a significant challenge for label-free imaging. We report a new speckle diffraction tomography (SDT) approach that can image thick biological specimens with ~500 nm lateral resolution and ~1 µm axial resolution in a reflection geometry. In SDT, multiple-scattering background is rejected through spatiotemporal gating provided by dynamic speckle-field interferometry, while depth-resolved refractive index maps are reconstructed by developing a comprehensive inverse-scattering model that also considers specimen-induced aberrations. Benefiting from the high-resolution and full-field quantitative imaging capabilities of SDT, we successfully imaged red blood cells and quantified their membrane fluctuations behind a turbid medium with a thickness of 2.8 scattering mean-free paths. Most importantly, we performed volumetric imaging of cornea inside an ex vivo rat eye and quantified its optical properties, including the mapping of nanoscale topographic features of Dua's and Descemet's membranes that had not been previously visualized.

SELECTION OF CITATIONS
SEARCH DETAIL