ABSTRACT
BACKGROUND: During the COVID-19 pandemic, antigen diagnostic tests were frequently used for screening, triage, and diagnosis. Novel instrument-based antigen tests (iAg tests) hold the promise of outperforming their instrument-free, visually-read counterparts. Here, we provide a systematic review and meta-analysis of the SARS-CoV-2 iAg tests' clinical accuracy. METHODS: We systematically searched MEDLINE (via PubMed), Web of Science, medRxiv, and bioRxiv for articles published before November 7th, 2022, evaluating the accuracy of iAg tests for SARS-CoV-2 detection. We performed a random effects meta-analysis to estimate sensitivity and specificity and used the QUADAS-2 tool to assess study quality and risk of bias. Sub-group analysis was conducted based on Ct value range, IFU-conformity, age, symptom presence and duration, and the variant of concern. RESULTS: We screened the titles and abstracts of 20,431 articles and included 114 publications that fulfilled the inclusion criteria. Additionally, we incorporated three articles sourced from the FIND website, totaling 117 studies encompassing 95,181 individuals, which evaluated the clinical accuracy of 24 commercial COVID-19 iAg tests. The studies varied in risk of bias but showed high applicability. Of 24 iAg tests from 99 studies assessed in the meta-analysis, the pooled sensitivity and specificity compared to molecular testing of a paired NP swab sample were 76.7% (95% CI 73.5 to 79.7) and 98.4% (95% CI 98.0 to 98.7), respectively. Higher sensitivity was noted in individuals with high viral load (99.6% [95% CI 96.8 to 100] at Ct-level ≤ 20) and within the first week of symptom onset (84.6% [95% CI 78.2 to 89.3]), but did not differ between tests conducted as per manufacturer's instructions and those conducted differently, or between point-of-care and lab-based testing. CONCLUSION: Overall, iAg tests have a high pooled specificity but a moderate pooled sensitivity, according to our analysis. The pooled sensitivity increases with lower Ct-values (a proxy for viral load), or within the first week of symptom onset, enabling reliable identification of most COVID-19 cases and highlighting the importance of context in test selection. The study underscores the need for careful evaluation considering performance variations and operational features of iAg tests.
Subject(s)
Antigens, Viral , COVID-19 Serological Testing , COVID-19 , SARS-CoV-2 , Sensitivity and Specificity , Humans , COVID-19/diagnosis , COVID-19/virology , SARS-CoV-2/immunology , COVID-19 Serological Testing/methods , Antigens, Viral/immunology , Antigens, Viral/analysis , COVID-19 Testing/methodsABSTRACT
BACKGROUND: Microscopic detection of malaria parasites is labour-intensive, time-consuming, and expertise-demanding. Moreover, the slide interpretation is highly dependent on the staining technique and the technician's expertise. Therefore, there is a growing interest in next-generation, fully- or semi-integrated microscopes that can improve slide preparation and examination. This study aimed to evaluate the clinical performance of miLab™ (Noul Inc., Republic of Korea), a fully-integrated automated microscopy device for the detection of malaria parasites in symptomatic patients at point-of-care in Sudan. METHODS: This was a prospective, case-control diagnostic accuracy study conducted in primary health care facilities in rural Khartoum, Sudan in 2020. According to the outcomes of routine on-site microscopy testing, 100 malaria-positive and 90 malaria-negative patients who presented at the health facility and were 5 years of age or older were enrolled consecutively. All consenting patients underwent miLab™ testing and received a negative or suspected result. For the primary analysis, the suspected results were regarded as positive (automated mode). For the secondary analysis, the operator reviewed the suspected results and categorized them as either negative or positive (corrected mode). Nested polymerase chain reaction (PCR) was used as the reference standard, and expert light microscopy as the comparator. RESULTS: Out of the 190 patients, malaria diagnosis was confirmed by PCR in 112 and excluded in 78. The sensitivity of miLab™ was 91.1% (95% confidence interval [CI] 84.2-95.6%) and the specificity was 66.7% (95% Cl 55.1-67.7%) in the automated mode. The specificity increased to 96.2% (95% Cl 89.6-99.2%), with operator intervention in the corrected mode. Concordance of miLab with expert microscopy was substantial (kappa 0.65 [95% CI 0.54-0.76]) in the automated mode, but almost perfect (kappa 0.97 [95% CI 0.95-0.99]) in the corrected mode. A mean difference of 0.359 was found in the Bland-Altman analysis of the agreement between expert microscopy and miLab™ for quantifying parasite counts. CONCLUSION: When used in a clinical context, miLab™ demonstrated high sensitivity but low specificity. Expert intervention was shown to be required to improve the device's specificity in its current version. miLab™ in the corrected mode performed similar to expert microscopy. Before clinical application, more refinement is needed to ensure full workflow automation and eliminate human intervention. Trial registration ClinicalTrials.gov: NCT04558515.
Subject(s)
Malaria , Microscopy , Point-of-Care Systems , Sensitivity and Specificity , Sudan , Microscopy/methods , Humans , Case-Control Studies , Prospective Studies , Female , Male , Child , Child, Preschool , Adult , Adolescent , Malaria/diagnosis , Young Adult , Middle AgedABSTRACT
The COVID-19 pandemic brought diagnostics into the spotlight in an unprecedented way not only for case management but also for population health, surveillance, and monitoring. The industry saw notable levels of investment and accelerated research which sparked a wave of innovation. Simple non-invasive sampling methods such as nasal swabs have become widely used in settings ranging from tertiary hospitals to the community. Self-testing has also been adopted as standard practice using not only conventional lateral flow tests but novel and affordable point-of-care molecular diagnostics. The use of new technologies, including artificial intelligence-based diagnostics, have rapidly expanded in the clinical setting. The capacity for next-generation sequencing and acceptance of digital health has significantly increased. However, 4 years after the pandemic started, the market for SARS-CoV-2 tests is saturated, and developers may benefit from leveraging their innovations for other diseases; tuberculosis (TB) is a worthwhile portfolio expansion for diagnostics developers given the extremely high disease burden, supportive environment from not-for-profit initiatives and governments, and the urgent need to overcome the long-standing dearth of innovation in the TB diagnostics field. In exchange, the current challenges in TB detection may be resolved by adopting enhanced swab-based molecular methods, instrument-based, higher sensitivity antigen detection technologies, and/or artificial intelligence-based digital health technologies developed for COVID-19. The aim of this article is to review how such innovative approaches for COVID-19 diagnosis can be applied to TB to have a comparable impact.
Subject(s)
COVID-19 , Tuberculosis , Humans , COVID-19 Testing , Pandemics , Artificial Intelligence , COVID-19/diagnosis , Tuberculosis/diagnosisABSTRACT
BACKGROUND: Microscopic examination is commonly used for malaria diagnosis in the field. However, the lack of well-trained microscopists in malaria-endemic areas impacted the most by the disease is a severe problem. Besides, the examination process is time-consuming and prone to human error. Automated diagnostic systems based on machine learning offer great potential to overcome these problems. This study aims to evaluate Malaria Screener, a smartphone-based application for malaria diagnosis. METHODS: A total of 190 patients were recruited at two sites in rural areas near Khartoum, Sudan. The Malaria Screener mobile application was deployed to screen Giemsa-stained blood smears. Both expert microscopy and nested PCR were performed to use as reference standards. First, Malaria Screener was evaluated using the two reference standards. Then, during post-study experiments, the evaluation was repeated for a newly developed algorithm, PlasmodiumVF-Net. RESULTS: Malaria Screener reached 74.1% (95% CI 63.5-83.0) accuracy in detecting Plasmodium falciparum malaria using expert microscopy as the reference after a threshold calibration. It reached 71.8% (95% CI 61.0-81.0) accuracy when compared with PCR. The achieved accuracies meet the WHO Level 3 requirement for parasite detection. The processing time for each smear varies from 5 to 15 min, depending on the concentration of white blood cells (WBCs). In the post-study experiment, Malaria Screener reached 91.8% (95% CI 83.8-96.6) accuracy when patient-level results were calculated with a different method. This accuracy meets the WHO Level 1 requirement for parasite detection. In addition, PlasmodiumVF-Net, a newly developed algorithm, reached 83.1% (95% CI 77.0-88.1) accuracy when compared with expert microscopy and 81.0% (95% CI 74.6-86.3) accuracy when compared with PCR, reaching the WHO Level 2 requirement for detecting both Plasmodium falciparum and Plasmodium vivax malaria, without using the testing sites data for training or calibration. Results reported for both Malaria Screener and PlasmodiumVF-Net used thick smears for diagnosis. In this paper, both systems were not assessed in species identification and parasite counting, which are still under development. CONCLUSION: Malaria Screener showed the potential to be deployed in resource-limited areas to facilitate routine malaria screening. It is the first smartphone-based system for malaria diagnosis evaluated on the patient-level in a natural field environment. Thus, the results in the field reported here can serve as a reference for future studies.
Subject(s)
Malaria, Falciparum , Malaria, Vivax , Malaria , Mobile Applications , Humans , Smartphone , Malaria/parasitology , Malaria, Falciparum/diagnosis , Malaria, Falciparum/parasitology , Malaria, Vivax/diagnosis , Plasmodium falciparum , Sensitivity and Specificity , Plasmodium vivaxABSTRACT
BACKGROUND: The emergence and spread of Plasmodium falciparum parasites that lack HRP2/3 proteins and the resulting decreased utility of HRP2-based malaria rapid diagnostic tests (RDTs) prompted the World Health Organization and other global health stakeholders to prioritize the discovery of novel diagnostic biomarkers for malaria. METHODS: To address this pressing need, we adopted a dual, systematic approach by conducting a systematic review of the literature for publications on diagnostic biomarkers for uncomplicated malaria and a systematic in silico analysis of P. falciparum proteomics data for Plasmodium proteins with favorable diagnostic features. RESULTS: Our complementary analyses led us to 2 novel malaria diagnostic biomarkers compatible for use in an RDT format: glyceraldehyde 3-phosphate dehydrogenase and dihydrofolate reductase-thymidylate synthase. CONCLUSIONS: Overall, our results pave the way for the development of next-generation malaria RDTs based on new antigens by identifying 2 lead candidates with favorable diagnostic features and partially de-risked product development prospects.
Subject(s)
Malaria, Falciparum , Malaria , Antigens, Protozoan , Biomarkers/analysis , Diagnostic Tests, Routine/methods , Humans , Malaria/diagnosis , Malaria, Falciparum/diagnosis , Plasmodium falciparum/genetics , Protozoan Proteins , Sensitivity and SpecificityABSTRACT
Background: Despite the increased use and worldwide distribution of malaria rapid diagnostic tests (RDTs) that distinguish between Plasmodium falciparum and non-falciparum species, little is known about their performance detecting Plasmodium knowlesi (Pk), Plasmodium malariae (Pm), and Plasmodium ovale (Po). This review seeks to analyze the results of published studies evaluating the diagnostic accuracy of malaria RDTs in detecting Pk, Pm, and Po monoinfections. Methods: MEDLINE, EMBASE, Web of Science, and CENTRAL databases were systematically searched to identify studies that reported the performance of RDTs in detecting Pk, Pm, and Po monoinfections. Results: Among 40 studies included in the review, 3 reported on Pk, 8 on Pm, 5 on Po, 1 on Pk and Pm, and 23 on Pm and Po infections. In the meta-analysis, estimates of sensitivities of RDTs in detecting Pk infections ranged 2%-48%. Test performances for Pm and Po infections were less accurate and highly heterogeneous, mainly because of the small number of samples tested. Conclusions: Limited data available suggest that malaria RDTs show suboptimal performance for detecting Pk, Pm, and Po infections. New improved RDTs and appropriately designed cross-sectional studies to demonstrate the usefulness of RDTs in the detection of neglected Plasmodium species are urgently needed.
Subject(s)
Diagnostic Tests, Routine/methods , Immunoassay/methods , Malaria/diagnosis , Plasmodium knowlesi/isolation & purification , Plasmodium malariae/isolation & purification , Plasmodium ovale/isolation & purification , Humans , Malaria/parasitology , Sensitivity and Specificity , Time FactorsABSTRACT
TORC1 is a conserved multisubunit kinase complex that regulates many aspects of eukaryotic growth including the biosynthesis of ribosomes. The TOR protein kinase resident in TORC1 is responsive to environmental cues and is potently inhibited by the natural product rapamycin. Recent characterization of the rapamycin-sensitive phosphoproteome in yeast has yielded insights into how TORC1 regulates growth. Here, we show that Sch9, an AGC family kinase and direct substrate of TORC1, promotes ribosome biogenesis (Ribi) and ribosomal protein (RP) gene expression via direct inhibitory phosphorylation of the transcriptional repressors Stb3, Dot6 and Tod6. Deletion of STB3, DOT6 and TOD6 partially bypasses the growth and cell size defects of an sch9 strain and reveals interdependent regulation of both Ribi and RP gene expression, and other aspects of Ribi. Dephosphorylation of Stb3, Dot6 and Tod6 enables recruitment of the RPD3L histone deacetylase complex to repress Ribi/RP gene promoters. Taken together with previous studies, these results suggest that Sch9 is a master regulator of ribosome biogenesis through the control of Ribi, RP, ribosomal RNA and tRNA gene transcription.
Subject(s)
Gene Expression Regulation, Fungal , RNA, Ribosomal/biosynthesis , Ribosomal Proteins/biosynthesis , Saccharomyces cerevisiae Proteins/metabolism , Saccharomyces cerevisiae/genetics , Saccharomyces cerevisiae/metabolism , Signal Transduction , RNA, Transfer/biosynthesis , Transcription, GeneticABSTRACT
Introduction: Rapid and accurate point-of-care (POC) tuberculosis (TB) diagnostics are a key priority to close the TB diagnostic gap of 3.1 million people without a diagnosis. Leveraging the recent surge in COVID-19 diagnostic innovation, we explored the potential adaptation of commercially available SARS-CoV-2 tests for TB diagnosis, aligning with World Health Organization (WHO) target product profiles (TPPs). Methods: A scoping review was conducted following PRISMA-ScR guidelines to systematically map commercially available POC molecular and antigen SARS-CoV-2 diagnostic tests potentially meeting the TPPs for TB diagnostic tests for peripheral settings. Data were gathered from PubMed/MEDLINE, bioRxiv, and medRxiv, along with publicly accessible in vitro diagnostic test databases, and developer websites, up to November 23, 2022. Data on developer and test attributes, operational characteristics, pricing, and clinical performance were charted using standardized data extraction forms. Each identified test was evaluated using a standardized scorecard. A narrative synthesis of the charted data is presented. Results: Our database search yielded 2,003 studies, from which 408 were considered eligible. Among these, we identified 58 commercialized diagnostic devices, including 17 near-POC antigen tests, one POC molecular test, 29 near-POC molecular tests, and 11 low-complexity molecular tests. We summarized the detailed characteristics, regulatory status, and clinical performance data of these tests. The LumiraDx (Roche, Switzerland) emerged as the highest- scoring near-POC antigen platform, while Visby (Visby, USA) was the highest-performing near-POC molecular platform. The Lucira Check-It (Pfizer, USA) was noted as the sole POC molecular test. The Idylla TM (Biocartis, Switzerland) was identified as the leading low- complexity molecular test. Discussion: We highlight a diverse landscape of commercially available diagnostic tests suitable for potential adaptation to TB POC testing. This work aims to bolster global TB initiatives by fostering stakeholder collaboration, leveraging COVID-19 diagnostic technologies for TB diagnosis, and uncovering new commercial avenues to tackle longstanding challenges in TB diagnosis.
ABSTRACT
Rapid and accurate point-of-care (POC) tuberculosis (TB) diagnostics are crucial to bridge the TB diagnostic gap. Leveraging recent advancements in COVID-19 diagnostics, we explored adapting commercially available POC SARS-CoV-2 tests for TB diagnosis in line with the World Health Organization (WHO) target product profiles (TPPs). A scoping review was conducted following PRISMA-ScR guidelines to systematically map POC antigen and molecular SARS-CoV-2 diagnostic tests potentially meeting the TPPs for TB diagnostic tests for peripheral settings. Data were gathered from PubMed/MEDLINE, bioRxiv, medRxiv, publicly accessible in vitro diagnostic test databases, and developer websites up to 23 November 2022. Data on developer attributes, operational characteristics, pricing, clinical performance, and regulatory status were charted using standardized data extraction forms and evaluated with a standardized scorecard. A narrative synthesis of the data is presented. Our search yielded 2003 reports, with 408 meeting eligibility criteria. Among these, we identified 66 commercialized devices: 22 near-POC antigen tests, 1 POC molecular test, 31 near-POC molecular tests, and 12 low-complexity molecular tests potentially adaptable for TB. The highest-scoring SARS-CoV-2 diagnostic tests were the near-POC antigen platform LumiraDx (Roche, Basel, Switzerland), the POC molecular test Lucira Check-It (Pfizer, New York, NY, USA), the near-POC molecular test Visby (Visby, San Jose, CA, USA), and the low-complexity molecular platform Idylla (Biocartis, Lausanne, Switzerland). We highlight a diverse landscape of commercially available diagnostic tests suitable for potential adaptation to peripheral TB testing. This work aims to bolster global TB initiatives by fostering stakeholder collaboration, leveraging SARS-CoV-2 diagnostic technologies for TB, and uncovering new commercial avenues to tackle longstanding challenges in TB diagnosis.
ABSTRACT
INTRODUCTION: In 2014, the WHO published high-priority target product profiles (TPPs) for new tuberculosis (TB) diagnostics to align end-user needs with test targets and specifications; nevertheless, no TB test meets these targets to date. The COVID-19-driven momentum in the diagnostics world offers an opportunity to address the long-standing lack of innovation in the field of TB diagnostics. This scoping review aims to summarise point-of-care (POC) molecular and antigen tests for COVID-19 diagnosis that, when applied to TB, potentially meet WHO TPPs. This summary of currently available innovative diagnostic tools will guide the development of novel TB diagnostics toward the WHO-set targets. METHODS AND ANALYSIS: We will follow the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension Scoping Reviews recommendations. MEDLINE (via PubMed), bioRxiv, MedRxiv and other publicly available in vitro diagnostic test databases were searched on 23 November 2022. POC antigen or molecular tests developed for SARS-CoV-2 detection that meet the eligibility criteria will be included in the review. Developer description, test description, operation characteristics, pricing information, performance and commercialisation status of diagnostic tests identified will be extracted using a predefined standardised data extraction form. Two reviewers will independently perform the screening and data extraction. A narrative synthesis of the final data will be provided. ETHICS AND DISSEMINATION: No ethical approval is required because individual patient data will not be included. The findings will be published in open-access scientific journals.
Subject(s)
COVID-19 , Tuberculosis , Humans , COVID-19/diagnosis , COVID-19 Testing , Point-of-Care Testing , Research Design , Review Literature as Topic , SARS-CoV-2 , Tuberculosis/diagnosisABSTRACT
Self-testing is an effective tool to bridge the testing gap for several infectious diseases; however, its performance in detecting SARS-CoV-2 using antigen-detection rapid diagnostic tests (Ag-RDTs) has not been systematically reviewed. This study aimed to inform WHO guidelines by evaluating the accuracy of COVID-19 self-testing and self-sampling coupled with professional Ag-RDT conduct and interpretation. Articles on this topic were searched until November 7th, 2022. Concordance between self-testing/self-sampling and fully professional-use Ag-RDTs was assessed using Cohen's kappa. Bivariate meta-analysis yielded pooled performance estimates. Quality and certainty of evidence were evaluated using QUADAS-2 and GRADE tools. Among 43 studies included, twelve reported on self-testing, and 31 assessed self-sampling only. Around 49.6% showed low risk of bias. Overall concordance with professional-use Ag-RDTs was high (kappa 0.91 [95% confidence interval (CI) 0.88-0.94]). Comparing self-testing/self-sampling to molecular testing, the pooled sensitivity and specificity were 70.5% (95% CI 64.3-76.0) and 99.4% (95% CI 99.1-99.6), respectively. Higher sensitivity (i.e., 93.6% [95% CI 90.4-96.8] for Ct < 25) was estimated in subgroups with higher viral loads using Ct values as a proxy. Despite high heterogeneity among studies, COVID-19 self-testing/self-sampling exhibits high concordance with professional-use Ag-RDTs. This suggests that self-testing/self-sampling can be offered as part of COVID-19 testing strategies.Trial registration: PROSPERO: CRD42021250706.
Subject(s)
COVID-19 Testing , COVID-19 , Humans , SARS-CoV-2 , COVID-19/diagnosis , Rapid Diagnostic Tests , Self-Testing , Sensitivity and SpecificityABSTRACT
Background: Plasmodium knowlesi causes zoonotic malaria across Southeast Asia. First-line diagnostic microscopy cannot reliably differentiate P. knowlesi from other human malaria species. Rapid diagnostic tests (RDTs) designed for P. falciparum and P. vivax are used routinely in P. knowlesi co-endemic areas despite potential cross-reactivity for species-specific antibody targets. Methods: Ten RDTs were evaluated: nine to detect clinical P. knowlesi infections from Malaysia, and nine assessing limit of detection (LoD) for P. knowlesi (PkA1-H.1) and P. falciparum (Pf3D7) cultures. Targets included Plasmodium-genus parasite lactate dehydrogenase (pan-pLDH) and P. vivax (Pv)-pLDH. Results: Samples were collected prior to antimalarial treatment from 127 patients with microscopy-positive PCR-confirmed P. knowlesi mono-infections. Median parasitaemia was 788/µL (IQR 247-5,565/µL). Pan-pLDH sensitivities ranged from 50.6% (95% CI 39.6-61.5) (SD BIOLINE) to 87.0% (95% CI 75.1-94.6) (First Response® and CareStart™ PAN) compared to reference PCR. Pv-pLDH RDTs detected P. knowlesi with up to 92.0% (95% CI 84.3-96.7%) sensitivity (Biocredit™). For parasite counts ≥200/µL, pan-pLDH (Standard Q) and Pv-pLDH RDTs exceeded 95% sensitivity. Specificity of RDTs against 26 PCR-confirmed negative controls was 100%. Sensitivity of six highest performing RDTs were not significantly different when comparing samples taken before and after (median 3 hours) antimalarial treatment. Parasite ring stages were present in 30% of pre-treatment samples, with ring stage proportions (mean 1.9%) demonstrating inverse correlation with test positivity of Biocredit™ and two CareStart™ RDTs.For cultured P. knowlesi, CareStart™ PAN demonstrated the lowest LoD at 25 parasites/µL; LoDs of other pan-pLDH ranged from 98 to >2000 parasites/µL. Pv-pLDH LoD for P. knowlesi was 49 parasites/µL. No false-positive results were observed in either P. falciparum-pLDH or histidine-rich-protein-2 channels. Conclusion: Selected RDTs demonstrate sufficient performance for detection of major human malaria species including P. knowlesi in co-endemic areas where microscopy is not available, particularly for higher parasite counts, although cannot reliably differentiate among non-falciparum malaria.
Subject(s)
Antimalarials , Malaria, Falciparum , Malaria, Vivax , Malaria , Parasites , Plasmodium knowlesi , Animals , Humans , L-Lactate Dehydrogenase/analysis , Plasmodium vivax , Limit of Detection , Antimalarials/pharmacology , Antimalarials/therapeutic use , Plasmodium falciparum , Sensitivity and Specificity , Malaria, Falciparum/parasitology , Malaria/diagnosis , Malaria/parasitology , Malaria, Vivax/parasitology , Diagnostic Tests, Routine/methods , Antigens, Protozoan , Protozoan Proteins/analysisABSTRACT
Millions of cases of tuberculosis (TB) go undiagnosed each year. Better diagnostic tools are urgently needed. Biomarker-based or multiple marker biosignature-based tests, ideally performed on blood or urine, for the detection of active TB might help to meet target product profiles proposed by the World Health Organization for point-of-care testing. We conducted a systematic review to summarize evidence on proposed biomarkers and biosignatures and evaluate their quality and level of evidence. We screened the titles and abstracts of 7,631 citations and included 443 publications that fulfilled the inclusion criteria and were published in 2010-2017. The types of biomarkers identified included antibodies, cytokines, metabolic activity markers, mycobacterial antigens and volatile organic compounds. Only 47% of studies reported a culture-based reference standard and diagnostic sensitivity and specificity. Forty-four biomarkers (4%) were identified in high-quality studies and met the target product profile minimum criteria, of which two have been incorporated into commercial assays. Of the 44 highest-quality biomarkers, 24 (55%) were multiple marker biosignatures. No meta-analyses were performed owing to between-study heterogeneity. In conclusion, TB biomarker discovery studies are often poorly designed and findings are rarely confirmed in independent studies. Few markers progress to a further developmental stage. More validation studies that consider the intended diagnostic use cases and apply rigorous design are needed. The extracted data from this review are currently being used by FIND as the foundation of a dynamic database in which biomarker data and developmental status will be presented.
Subject(s)
Biomarkers/analysis , Mycobacterium tuberculosis/isolation & purification , Tuberculosis/diagnosis , Animals , Humans , Mycobacterium tuberculosis/classification , Mycobacterium tuberculosis/genetics , Tuberculosis/microbiologyABSTRACT
In the original version of this Analysis, author Seda Yerlikaya was mistakenly spelled as Seda Yerliyaka. This has now been amended.
ABSTRACT
New diagnostic innovations for tuberculosis (TB), including point-of-care solutions, are critical to reach the goals of the End TB Strategy. However, despite decades of research, numerous reports on new biomarker candidates, and significant investment, no well-performing, simple and rapid TB diagnostic test is yet available on the market, and the search for accurate, non-DNA biomarkers remains a priority. To help overcome this 'biomarker pipeline problem', FIND and partners are working on the development of a well-curated and user-friendly TB biomarker database. The web-based database will enable the dynamic tracking of evidence surrounding biomarker candidates in relation to target product profiles (TPPs) for needed TB diagnostics. It will be able to accommodate raw datasets and facilitate the verification of promising biomarker candidates and the identification of novel biomarker combinations. As such, the database will simplify data and knowledge sharing, empower collaboration, help in the coordination of efforts and allocation of resources, streamline the verification and validation of biomarker candidates, and ultimately lead to an accelerated translation into clinically useful tools.
Subject(s)
Biomarkers , Databases, Factual , Tuberculosis/diagnosis , HumansABSTRACT
Nutrient-sensitive phosphorylation of the S6 protein of the 40S subunit of the eukaryote ribosome is highly conserved. However, despite four decades of research, the functional consequences of this modification remain unknown. Revisiting this enigma in Saccharomyces cerevisiae, we found that the regulation of Rps6 phosphorylation on Ser-232 and Ser-233 is mediated by both TOR complex 1 (TORC1) and TORC2. TORC1 regulates phosphorylation of both sites via the poorly characterized AGC-family kinase Ypk3 and the PP1 phosphatase Glc7, whereas TORC2 regulates phosphorylation of only the N-terminal phosphosite via Ypk1. Cells expressing a nonphosphorylatable variant of Rps6 display a reduced growth rate and a 40S biogenesis defect, but these phenotypes are not observed in cells in which Rps6 kinase activity is compromised. Furthermore, using polysome profiling and ribosome profiling, we failed to uncover a role of Rps6 phosphorylation in either global translation or translation of individual mRNAs. Taking the results together, this work depicts the signaling cascades orchestrating Rps6 phosphorylation in budding yeast, challenges the notion that Rps6 phosphorylation plays a role in translation, and demonstrates that observations made with Rps6 knock-ins must be interpreted cautiously.
Subject(s)
Multiprotein Complexes/metabolism , Ribosomal Protein S6/metabolism , TOR Serine-Threonine Kinases/metabolism , Mechanistic Target of Rapamycin Complex 1 , Mechanistic Target of Rapamycin Complex 2 , Phosphorylation/physiology , Polyribosomes/metabolism , Protein Serine-Threonine Kinases/metabolism , Ribosomal Protein S6/genetics , Ribosome Subunits, Small, Eukaryotic/metabolism , Ribosomes/metabolism , Saccharomyces cerevisiae/metabolism , Saccharomyces cerevisiae Proteins/metabolism , Signal Transduction/genetics , Transcription Factors/metabolismABSTRACT
Immunostimulatory properties of mushroom derived polysaccharides (PS) as stand-alone agents were tested. Next, PS were nanocomplexed with polyI:C (pIC) to yield stable nanoparticles around 200 nm in size evidenced by atomic force microscopy and dynamic light scattering analyses. PSs were selectively engaged by cells expressing TLR2 and initiated NFκB dependent signaling cascade leading to a Th1-biased cytokine/chemokine secretion in addition to bactericidal nitric oxide (NO) production from macrophages. Moreover, cells treated with nanoparticles led to synergistic IL6, production and upregulation of TNFα, MIP3α, IFNγ and IP10 transcript expression. In mice, PS-Ovalbumin-pIC formulation surpassed anti-OVA IgG responses when compared to either PS-OVA or pIC-OVA mediated immunity. Our results revealed that signal transduction initiated both by TLR2 and TLR3 via co-delivery of pIC by PS in nanoparticle depot delivery system is an effective immunization strategy. The present work implicate that the PS and nucleic acid based nanoparticle approach along with protein antigens can be harnessed to prevent infectious diseases.
Subject(s)
Immunization , Interferon Inducers/immunology , Nanoparticles/chemistry , Poly I-C/immunology , Polysaccharides/immunology , Adjuvants, Immunologic , Agaricales/chemistry , Animals , Cell Line , Dose-Response Relationship, Drug , Female , Humans , Interleukin-16/immunology , Interleukin-18/immunology , Mice , Mice, Inbred BALB C , Mice, Inbred C57BL , Microscopy, Atomic Force , Nitric Oxide/metabolism , Toll-Like Receptors/immunology , Tumor Necrosis Factor-alpha/metabolismABSTRACT
Emerging evidence supports the notion that claudins (Cldns) are dynamically regulated under normal conditions to respond to the selective permeability requirements of various tissues, and that their expression is developmentally controlled. We describe the localization of those Cldns that we have previously demonstrated to be functionally important in epidermal differentiation and the formation of the epidermal permeability barrier, e.g., Cldn1, Cldn6, Cldn11, and Cldn18, and the presence of Cldn3 and Cldn5 in various neonatal mouse epithelia including the epidermis, nail, oral mucosa, tongue, and stomach. Cldn1 is localized in the differentiated and/or undifferentiated compartments of the epidermis and nail and in the dorsal surface of the tongue and glandular compartment of the stomach but is absent from the oral mucosa and the keratinized compartment of the stomach. Cldn3 is present in the basal cells of the nail matrix and both compartments of the murine stomach but not in the epidermis, oral mucosa, or tongue. Cldn5 is found in the glandular compartment of the stomach but not in the epidermis, nail unit, oral mucosa, forestomach, and tongue. Cldn6, Cldn11, and Cldn18 occur in the differentiating suprabasal compartment of the epidermis, nail, and oral mucosa and in the dorsal and ventral surfaces of the tongue and the keratinized squamous epithelium of the stomach. The simple columnar epithelium of the glandular stomach stains for Cldn18 and reveals a non-membranous pattern for Cldn6 and Cldn11 expression. Our results demonstrate differential Cldn protein profiles in various epithelial tissues and their differentiation stages. Although the molecular mechanisms regulating Cldn expression are unknown, elucidation of their differential localization patterns in tissues with diverse permeability requirements should provide a better understanding of the role of tight junctions in tissue function.