Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Am J Physiol Cell Physiol ; 327(5): C1192-C1201, 2024 Nov 01.
Article in English | MEDLINE | ID: mdl-39246142

ABSTRACT

Cell migration is a fundamental and functional cellular process, influenced by a complex microenvironment consisting of different cells and extracellular matrix. Recent research has highlighted that, besides biochemical cues from the microenvironment, physical cues can also greatly alter cellular behavior. However, due to the complexity of the microenvironment, little is known about how the physical interactions between migrating cells and surrounding microenvironment instructs cell movement. Here, we explore various examples of three-dimensional microenvironment reconstruction models in vitro and describe how the physical interplay between migrating cells and the neighboring microenvironment controls cell behavior. Understanding this mechanical cooperation will provide key insights into organ development, regeneration, and tumor metastasis.


Subject(s)
Cell Movement , Cellular Microenvironment , Extracellular Matrix , Cell Movement/physiology , Humans , Animals , Extracellular Matrix/metabolism , Tumor Microenvironment , Models, Biological
2.
Anal Chem ; 95(4): 2366-2374, 2023 01 31.
Article in English | MEDLINE | ID: mdl-36655581

ABSTRACT

Before fertilization, sperms adhere to oviductal epithelium cells, and only a restrictive number of winner sperms can escape to reach the egg. To study the sperm escape behavior from the oviductal surface, we developed a microfluidic chip to fabricate an adhesive surface and to create a gradient of progesterone (P4) for mimicking the oviduct microenvironment in vivo. We identified three sperm motion patterns in such a microenvironment─anchored spin, run-and-spin, and escaped mode. By using kinetic analysis, we verified the hypothesis that the responsive rotation energy anchored with the adhered sperm head determines whether the sperm is trapped or detaching, which is defined as the hammer flying strategy of successful escape after accumulating energy in the process of rotating. Intriguingly, this hammer-throw escaping is able to be triggered by the P4 biochemical stimulation. Our results revealed the tangled process of sperm escape before fertilization in the ingenious microfluidic system.


Subject(s)
Biomimetics , Semen , Humans , Female , Male , Animals , Kinetics , Spermatozoa , Oviducts
3.
J Med Virol ; 95(8): e29041, 2023 08.
Article in English | MEDLINE | ID: mdl-37621182

ABSTRACT

The emerging outbreak of monkeypox is closely associated with the viral infection and spreading, threatening global public health. Virus-induced cell migration facilitates viral transmission. However, the mechanism underlying this type of cell migration remains unclear. Here we investigate the motility of cells infected by vaccinia virus (VACV), a close relative of monkeypox, through combining multi-omics analyses and high-resolution live-cell imaging. We find that, upon VACV infection, the epithelial cells undergo epithelial-mesenchymal transition-like transformation, during which they lose intercellular junctions and acquire the migratory capacity to promote viral spreading. After transformation, VACV-hijacked RhoA signaling significantly alters cellular morphology and rearranges the actin cytoskeleton involving the depolymerization of robust actin stress fibers, leading-edge protrusion formation, and the rear-edge recontraction, which coordinates VACV-induced cell migration. Our study reveals how poxviruses alter the epithelial phenotype and regulate RhoA signaling to induce fast migration, providing a unique perspective to understand the pathogenesis of poxviruses.


Subject(s)
Mpox (monkeypox) , Vaccinia virus , Humans , Cell Movement , Disease Outbreaks , Epithelial Cells
4.
ACS Appl Mater Interfaces ; 16(5): 5401-5411, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38271201

ABSTRACT

Nanostructure-enhanced biodetection is widely used for early diagnosis and treatment, which plays an essential role in improving the cure rates of cancer patients. ZnO nanostructure-based fluorescence immunoassay has been demonstrated to enable effective and sensitive detection of cancer biomarkers for their excellent biocompatibility, high electrical point, and unique fluorescence enhancement properties. Further optimization of such fluorescence detection technology is still in demand to meet the requirements of highly sensitive, multiplex detection, and user-friendly devices. Droplet microfluidics is a promising platform for high-throughput analysis of biological assays, and they have been intensively used in analytical chemistry and synthesis of nanoparticles. Here, we propose a simple droplet chip, where a static droplet array was successfully obtained for in situ growth of ZnO nanostructures with varied diameters by changing the entire growth time and replenishment interval. This device provides a novel and alternative approach for patterned growth of ZnO nanostructures and understanding the growth condition of ZnO nanostructures in static droplet, which offers some guidance toward the design of multiple fluorescence amplification platforms potentially for biosensing. As a demonstration, we used the patterned grown ZnO nanostructures for multiple detection of cancer biomarkers, achieving a low limit of detection as low as 138 fg/mL in the human α-fetoprotein assay and 218 fg/mL in the carcinoembryonic antigen assay with a large dynamic range of 8 orders. These results suggest that such multifunctional microfluidic devices may be useful tools for efficient fluorescence diagnostic assays.


Subject(s)
Microfluidic Analytical Techniques , Nanoparticles , Nanostructures , Zinc Oxide , Humans , Microfluidics/methods , Zinc Oxide/chemistry , Nanostructures/chemistry , Biomarkers, Tumor
5.
Lab Chip ; 24(16): 3973-3984, 2024 Aug 06.
Article in English | MEDLINE | ID: mdl-39027967

ABSTRACT

The emergence of microfluidic devices integrated with nanostructures enables highly efficient, flexible and controllable biosensing, among which zinc oxide (ZnO) nanostructure-based fluorescence detection has been demonstrated to be a promising methodology due to its high electrical point and unique fluorescence enhancement properties. The optimization of microfluidic synthesis of ZnO nanostructures for biosensing on chip has been in demand due to its low cost and high efficiency, but still the flow-induced growth of ZnO nanostructures is not extensively studied. Here, we report a simple and versatile strategy that could manipulate the local flow field by creating periodically arranged micropillars within a straight microchannel. We have explored the effects of perfusion speed and flow direction of seed solution, localized flow variation of growth solution and growth time on the morphology of nanostructures. This provided a comprehensive understanding which governs nanostructure fabrication controlled by flow. The results demonstrated that localized flow in microfluidic devices was essential for the initiation and growth of zinc oxide crystals, enabling precise control over their properties and morphology. Furthermore, a model protein was used to demonstrate the intrinsic fluorescence enhancement of ZnO nanostructures as an example to reveal the morphology-related enhancement properties.

6.
Talanta ; 277: 126415, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38878513

ABSTRACT

Endothelial cells (ECs) migration is a crucial early step in vascular repair and tissue neovascularization. While extensive research has elucidated the biochemical drivers of endothelial motility, the impact of biophysical cues, including vessel geometry and topography, remains unclear. Herein, we present a novel approach to reconstruct 3D self-assembly blood vessels-on-a-chip that accurately replicates real vessel geometry and topography, surpassing conventional 2D flat tube formation models. This vessels-on-a-chip system enables real-time monitoring of vasculogenesis and ECs migration at high spatiotemporal resolution. Our findings reveal that ECs exhibit increased migration speed and directionality in response to narrower vessel geometries, transitioning from a rounded to a polarized morphology. These observations underscore the critical influence of vessel size in regulating ECs migration and morphology. Overall, our study highlights the importance of biophysical factors in shaping ECs behavior, emphasizing the need to consider such factors in future studies of endothelial function and vessel biology.


Subject(s)
Blood Vessels , Cell Movement , Human Umbilical Vein Endothelial Cells , Humans , Blood Vessels/cytology , Blood Vessels/physiology , Endothelial Cells/cytology , Lab-On-A-Chip Devices , Neovascularization, Physiologic
7.
iScience ; 26(12): 108575, 2023 Dec 15.
Article in English | MEDLINE | ID: mdl-38125027

ABSTRACT

The tumor-treating fields (TTFields) technology has revolutionized the management of recurrent and newly diagnosed glioblastoma (GBM) cases. To ameliorate this treatment modality for GBM and other oncological conditions, it is necessary to understand the biophysical principles of TTFields better. In this study, we further analyzed the mechanism of the electromagnetic exposure with varying frequencies and electric field strengths on cells in mitosis, specifically in telophase. In reference to previous studies, an intuitive finite element model of the mitotic cell was built for electromagnetic simulations, predicting a local increase in the cleavage furrow region, which may help explain TTFields' anti-proliferative effects. Cell experiments confirmed that the reduction in proliferation and migration of glioma cell by TTFields was in a frequency- and field-strength-dependent manner. This work provides unique insights into the selection of frequencies in the anti-proliferative effect of TTFields on tumors, which could improve the application of TTFields.

8.
Biosens Bioelectron ; 217: 114709, 2022 Dec 01.
Article in English | MEDLINE | ID: mdl-36115123

ABSTRACT

Osteosarcoma is one of the most frequent primary sarcoma of bone among adolescents. Early diagnosis of osteosarcoma is the key factor to achieve high survival rate of patients. Nevertheless, traditional histological biopsy is highly invasive and associated with the risk of arousing tumor spread. Herein, we develop a method integrating microfluidics and surface-enhanced Raman spectroscopy (SERS) to isolate plasma-derived exosomes and profile multiple exosomal biomarkers for the diagnosis of osteosarcoma. The method showed highly efficient isolation of exosomes directly from human plasma and can profile exosomes based on protein biomarkers, with the detection limit down to 2 exosomes per µL. The whole assay can be performed in 5 h and only consumed 50 µL of plasma for one analysis. With the method, we analyzed the level of three protein biomarkers, i.e., CD63, vimentin (VIM) and epithelial cell adhesion molecule (EpCAM), on plasma-derived exosomes from 20 osteosarcoma patients and 20 heathy controls. Significantly higher levels of CD63, VIM and EpCAM were observed on plasma exosomes from the osteosarcoma patients compared to the healthy controls. Based on the level of the exosomal biomarkers, a classification model was built for the rapid diagnosis of osteosarcoma, with the sensitivity, specificity and accuracy of 100%, 90% and 95%, respectively. The proposed method does not require complex operations nor expensive equipment, and has great promise in clinical diagnosis of cancer as a liquid biopsy technique.


Subject(s)
Biosensing Techniques , Bone Neoplasms , Exosomes , Osteosarcoma , Adolescent , Biomarkers, Tumor , Bone Neoplasms/diagnosis , Bone Neoplasms/metabolism , Epithelial Cell Adhesion Molecule/analysis , Exosomes/chemistry , Humans , Microfluidics/methods , Osteosarcoma/diagnosis , Osteosarcoma/metabolism , Vimentin/analysis , Vimentin/metabolism
9.
Biosens Bioelectron ; 204: 114040, 2022 May 15.
Article in English | MEDLINE | ID: mdl-35151944

ABSTRACT

As the gate for sperm swimming into the female reproductive tract, cervix is full of cervical mucus, which plays an important role in sperm locomotion. The fact that sperm cannot pass through the cervical mucus-cervix microenvironment will cause the male infertility. However, how the sperm swim across the cervix microenvironment remains elusive. We used hyaluronic acid (HA), a substitute of cervical mucus to mimic cervix microenvironment and designed a cervix chip to study sperm selection and behavior. An accumulation of sperm in HA confirmed that HA served as a reservoir for sperm, similar to cervical mucus. We found that sperm escaping from HA exhibited higher motility than the sperm accessing into HA, suggesting that HA functions as a filter to select sperm with high activity. Our findings construct a practical platform to explore the sophisticated interaction of sperm with cervix microenvironment, with elaborate swimming indicators thus provide a promising cervix chip for sperm selection with kinematic features on-demand. What's more, the cervix chip allows the convenient use in clinical infertility diagnosis, owing to the advantage of simple, fast and high efficiency.


Subject(s)
Biosensing Techniques , Sperm Motility , Cervix Mucus , Cervix Uteri , Female , Humans , Locomotion , Male , Spermatozoa
10.
Front Oncol ; 11: 709255, 2021.
Article in English | MEDLINE | ID: mdl-34527582

ABSTRACT

Plasma circulating extracellular vesicle (EV) has emerged as a promising biomarker for diagnosis and prognosis of various epithelial tumors. However, fast and efficient capture of EVs with microfluidic chip in sarcoma remains to be established. Herein, we reported a ZnO-nanorods integrated (ZNI) microfluidic chip, where EV capture antibody was uniformly grafted to the surface of the ZnO-nanorods of the chip to enhance the plasma turbulence formation and the capture efficiency at the micro-scale. Based on osteosarcoma (OS) cell line, we demonstrated that a combination of CD81 and CD63 antibody on ZNI chip yielded the greatest amount of total EVs, with an extra sensitive limit of detection (LOD) of ~104 particles mL-1. Furthermore, the addition of fluorescent labeling of Vimentin (VIM), a previously reported sarcoma cell surface biomarker, could enabled the dual visualization of total plasma EVs and VIM-positive EVs from OS patients' plasma. Based on our ZNI chip, we found that the amount of plasma total EVs was significantly different between OS and healthy donors (1562 a.u. versus 639 a.u., p< 0.05), but not between metastatic and nonmetastatic OS (p> 0.05). Interestingly, patients with metastatic disease had a significantly greater amount of VIM-positive EVs (1411 a.u. versus 231 a.u.., p< 0.05) and increased VIM-positive/total EVs ratio (0.943 versus 0.211, p< 0.05) in comparison with the nonmetastatic counterpart. Therefore, our ZNI microfluidic chip has great potential for the fast quantification of plasma EVs, and the microfluidic-based quantification of total and VIM-positive EVs might serve as a promising biomarker for the diagnosis and surveillance in OS patients.

SELECTION OF CITATIONS
SEARCH DETAIL