Results 1 - 20 de 31
Filter
1.
Audiol Neurootol ; 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38479363

ABSTRACT

BACKGROUND: Correct individual tonotopic frequency stimulation of the cochlea plays an important role in the further development of anatomy based cochlear implantation. In this context frequency specific fitting of the basal electrode contact with a normal insertion depth can be difficult since it is often placed in a frequency range higher than 10 kHz and current audio processors only stimulate for frequencies up to 8.5 kHz due to microphone characteristics. This results in a mismatch of the high frequencies. Therefore, this study represents a proof of concept for a tonotopic correct insertion and aims to develop an algorithm for a placement of the basal electrode below 8.5 kHz in an experimental setting. METHODS: Pre- and postoperative flat-panel volume CT scans with secondary reconstructions were performed in 10 human temporal bone specimens. The desired frequency location for the most basal electrode contact was set at 8.25 kHz. The distance from the round window to the position where the basal electrode contact was intended to be located was calculated preoperatively using 3D-curved multiplanar reconstruction and a newly developed mathematical approach. A specially designed cochlear implant electrode array with customized markers imprinted on the silicone of the electrode array was inserted in all specimens based on the individually calculated insertion depths. All postoperative measurements were additionally validated using an otological planning software. RESULTS: Positioning of the basal electrode contact was reached with only a small mean deviation of 37 ± 399 Hz and 0.06 ± 0.37 mm from the planned frequency of 8.25 kHz. The mean rotation angle up to the basal electrode contact was 51 ± 5 °. In addition, the inserted electrode array adequately covered the apical regions of the cochleae. CONCLUSION: Using this algorithm, it was possible to position the basal electrode array contact in an area of the cochlea that could be correctly stimulated by the existing speech processors in the context of tonotopic correct fitting.

2.
BMC Oral Health ; 24(1): 396, 2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38549137

ABSTRACT

BACKGROUND: The stability of implant-abutment connection is crucial to minimize mechanical and biological complications. Therefore, an assessment of the microgap behavior and abutment displacement in different implant-abutment designs was performed. METHODS: Four implant systems were tested, three with a conical implant-abutment connection based on friction fit and a cone angle < 12 ° (Medentika, Medentis, NobelActive) and a system with an angulated connection (< 40°) (Semados). In different static loading conditions (30 N - 90º, 100 N - 90º, 200 N - 30º) the microgap and abutment displacement was evaluated using synchrotron-based microtomography and phase-contrast radioscopy with numerical forward simulation of the optical Fresnel propagation yielding an accuracy down to 0.1 µm. RESULTS: Microgaps were present in all implant systems prior to loading (0.15-9 µm). Values increased with mounting force and angle up to 40.5 µm at an off axis loading of 100 N in a 90° angle. CONCLUSIONS: In contrast to the implant-abutment connection with a large cone angle (45°), the conical connections based on a friction fit (small cone angles with < 12°) demonstrated an abutment displacement which resulted in a deformation of the outer implant wall. The design of the implant-abutment connection seems to be crucial for the force distribution on the implant wall which might influence peri-implant bone stability.


Subject(s)
Dental Implants , Synchrotrons , Humans , Dental Implant-Abutment Design , Computer Simulation , Dental Abutments , Dental Stress Analysis
4.
Eur J Orthod ; 39(3): 310-319, 2017 06 01.
Article in English | MEDLINE | ID: mdl-27365182

ABSTRACT

Objective: The purpose of this study was to estimate the feasibility and accuracy of mesio-distal width measurements with magnetic resonance imaging (MRI) in comparison to conventional 3D imaging techniques [multi-slice CT (MSCT), cone-beam CT (CBCT), and µCT]. The measured values of the tooth widths were compared to each other to estimate the amount of radiation necessary to enable orthodontic diagnostics. Material and Methods: Two pig skulls were measured with MSCT, CBCT, µCT, and MRI. Three different judges were asked to determine the mesio-distal tooth width of 14 teeth in 2D tomographic images and in 3D segmented images via a virtual ruler in every imaging dataset. Results: Approximately 19% (27/140) of all test points in 2D tomographic slice images and 12% (17/140) of the test points in 3D segmented images showed a significant difference (P ≤ 0.05). The largest significant difference was 1.6mm (P < 0.001). There were fewer significant differences in the measurement of the tooth germs than in erupted teeth. Conclusions: Measurement of tooth width by MRI seems to be clinically equivalent to the conventional techniques (CBCT and MSCT). Tooth germs are better illustrated than erupted teeth on MRI. Three-dimensional segmented images offer only a slight advantage over 2D tomographic slice images. MRI, which avoids radiation, is particularly appealing in adolescents if these data can be corroborated in further studies.


Subject(s)
Odontometry/methods , Tooth/anatomy & histology , Anatomic Landmarks , Animals , Cone-Beam Computed Tomography/methods , Imaging, Three-Dimensional/methods , Jaw/anatomy & histology , Jaw/diagnostic imaging , Magnetic Resonance Imaging/methods , Observer Variation , Radiation Dosage , Reproducibility of Results , Sus scrofa , Tomography, X-Ray Computed/methods , Tooth/diagnostic imaging , Tooth Germ/anatomy & histology , Tooth Germ/diagnostic imaging
5.
J Synchrotron Radiat ; 22(6): 1492-7, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26524314

ABSTRACT

Synchrotron real-time radioscopy and in situ microtomography are the only techniques providing direct visible information on a micrometre scale of local deformation in the implant-abutment connection (IAC) during and after cyclic loading. The microgap formation at the IAC has been subject to a number of studies as it has been proposed to be associated with long-term implant success. The next step in this scientific development is to focus on the in situ fatigue procedure of two-component dental implants. Therefore, an apparatus has been developed which is optimized for the in situ fatigue analysis of dental implants. This report demonstrates both the capability of in situ radioscopy and microtomography at the ID19 beamline for the study of cyclic deformation in dental implants. The first results show that it is possible to visualize fatigue loading of dental implants in real-time radioscopy in addition to the in situ fatigue tomography. For the latter, in situ microtomography is applied during the cyclic loading cycles in order to visualize the opening of the IAC microgap. These results concur with previous ex situ studies on similar systems. The setup allows for easily increasing the bending force, to simulate different chewing situations, and is, therefore, a versatile tool for examining the fatigue processes of dental implants and possibly other specimens.


Subject(s)
Dental Implant-Abutment Design/methods , Dental Implants , Imaging, Three-Dimensional/methods , Materials Testing/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, Optical/methods , Compressive Strength , Dental Stress Analysis , Stress, Mechanical
6.
Opt Express ; 23(25): 32718-27, 2015 Dec 14.
Article in English | MEDLINE | ID: mdl-26699061

ABSTRACT

Here we present a method for the removal of multi-material artifacts which occur during the application of a single material phase retrieval procedure to X-ray tomographic data sets. For the phase retrieval we chose the most common method which is the single material filter. The correction method which we describe in the following has been designed for samples consisting of three distinct materials, hence effectively two different material interfaces. Furthermore the material phase with the strongest X-ray interaction needs to show sufficient absorption in order to allow for segmenting this phase through application of a grey value threshold. If these conditions are fulfilled the method is easy to apply through post processing as is shown for the volume images of two sample types.

7.
Otol Neurotol ; 45(3): e234-e240, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38238926

ABSTRACT

HYPOTHESIS: Measurements of the cochlear duct length (CDL) are dependent on the resolution of the imaging dataset. BACKGROUND: Previous research has shown highly precise cochlear measurements using 3D-curved multiplanar reconstruction (MPR) and flat-panel volume computed tomography (fpVCT). Thus far, however, there has been no systematic evaluation of the imaging dataset resolution required for optimal CDL measurement. Therefore, the aim of this study was to evaluate the dependence of CDL measurement on the resolution of the imaging dataset to establish a benchmark for future CDL measurements. METHODS: fpVCT scans of 10 human petrous bone specimens were performed. CDL was measured using 3D-curved MPR with secondary reconstruction of the fpVCT scans (fpVCT SECO ) and increasing resolution from 466 to 99 µm. In addition, intraobserver variability was evaluated. A best-fit function for calculation of the CDL was developed to provide a valid tool when there are no measurements done with high-resolution imaging datasets. RESULTS: Comparison of different imaging resolution settings showed significant differences for CDL measurement in most of the tested groups ( p < 0.05), except for the two groups with the highest resolution. Imaging datasets with a resolution lower than 200 µm showed lower intraobserver variability than the other resolution settings, although there were no clinically unacceptable errors with respect to the Bland-Altman plots. The developed best-fit function showed high accuracy for CDL calculation using resolution imaging datasets of 300 µm or lower. CONCLUSION: 3D-curved MPR in fpVCT with a resolution of the imaging dataset of 200 µm or higher revealed the most precise CDL measurement. There was no benefit of using a resolution higher than 200 µm with regard to the accuracy of the CDL measurement.


Subject(s)
Cochlear Implantation , Cochlear Implants , Humans , Tomography, X-Ray Computed/methods , Cochlear Duct/surgery , Cochlea/diagnostic imaging , Cochlea/surgery , Cone-Beam Computed Tomography , Petrous Bone/diagnostic imaging , Petrous Bone/surgery , Cochlear Implantation/methods
8.
Opt Express ; 21(17): 19922-33, 2013 Aug 26.
Article in English | MEDLINE | ID: mdl-24105538

ABSTRACT

Over the recent years X-ray differential phase-contrast imaging was developed for the hard X-ray regime as produced from laboratory X-ray sources. The technique uses a grating-based Talbot-Lau interferometer and was shown to yield image contrast gain, which makes it very interesting to the fields of medical imaging and non-destructive testing, respectively. In addition to X-ray attenuation contrast, the differential phase-contrast and dark-field images provide different structural information about a specimen. For the dark-field even at length scales much smaller than the spatial resolution of the imaging system. Physical interpretation of the dark-field information as present in radiographic and tomographic (CT) images requires a detailed look onto the geometric orientation between specimen and the setup. During phase-stepping the drop in intensity modulation, due to local scattering effects within the specimen is reproduced in the dark-field signal. This signal shows strong dependencies on micro-porosity and micro-fibers if these are numerous enough in the object. Since a grating-interferometer using a common unidirectional line grating is sensitive to X-ray scattering in one plane only, the dark-field image is influenced by the fiber orientations with respect to the grating bars, which can be exploited to obtain anisotropic structural information. With this contribution, we attempt to extend existing models for 2D projections to 3D data by analyzing dark-field contrast tomography of anisotropically structured materials such as carbon fiber reinforced carbon (CFRC).

9.
Int J Oral Maxillofac Implants ; 38(3): 489-495, 2023.
Article in English | MEDLINE | ID: mdl-37279213

ABSTRACT

PURPOSE: To evaluate the effect of implant body diameter, platform diameter, and the use of transepithelial components on implant-abutment connection (IAC) microgap width. MATERIALS AND METHODS: In total, 16 tests were performed on four commercial dental restoration models (BTI Biotechnology Institute). Different static loads were applied to the embedded implants according to the International Organization for Standardization (ISO) 14801, using a customized loading device. Measurements of the microgap were taken by means of highly magnified x-ray projection in situ in a micro-CT scanner. Regression models were obtained and compared through an analysis of covariance (ANCOVA). To quantify the effect of each variable, t tests (α = .05) of experimental results were performed. RESULTS: Under 400 N, using a transepithelial component for the dental restoration, the microgap width was reduced by 20% (P = .044). Meanwhile, a 22% microgap reduction was observed when the implant body diameter was increased by 1 mm (P = .024). Finally, increasing the platform diameter by 1.4 mm led to a microgap reduction of 54% (P = .001). CONCLUSION: The use of a transepithelial component in dental restorations reduces the microgap width in IACs. Furthermore, given sufficient space for the implantation, larger implant bodies and platform diameters can also be used for this purpose. Int J Oral Maxillofac Implants 2023;38:489-495. doi: 10.11607/jomi.9855.


Subject(s)
Dental Implants , X-Rays , Dental Abutments , Dental Implantation, Endosseous/methods , Radiography , Dental Implant-Abutment Design
10.
Materials (Basel) ; 16(2)2023 Jan 10.
Article in English | MEDLINE | ID: mdl-36676409

ABSTRACT

This study focuses on the influence of additive manufacturing process strategies on the specimen geometry, porosity, microstructure and mechanical properties as well as their impacts on the design of metamaterials. Filigree additively manufactured NiTi specimens with diameters between 180 and 350 µm and a nominal composition of Ni50.9Ti49.1 (at %) were processed by laser powder bed fusion in a first step. Secondly, they structures were characterized by optical and electron microscopy as well as micro tomography to investigate the interrelations between the process parameters, specimen diameters and microstructure. Each specimen was finally tested in a micro tensile machine to acquire the mechanical performance. The process strategy had, besides the resulting specimen diameter, an impact on the microstructure (grain size) without negatively influencing its quality (porosity). All specimens revealed a superelastic response while the critical martensitic phase transition stress decreased with the applied vector length. As a conclusion, and since the design of programmable metamaterials relies on the accuracy of FEM simulations, precise and resource-efficient testing of filigree and complex structures remains an important part of creating a new type of metamaterials with locally adjusted material behavior.

11.
Sci Rep ; 13(1): 19057, 2023 11 04.
Article in English | MEDLINE | ID: mdl-37925540

ABSTRACT

Automated analysis of the inner ear anatomy in radiological data instead of time-consuming manual assessment is a worthwhile goal that could facilitate preoperative planning and clinical research. We propose a framework encompassing joint semantic segmentation of the inner ear and anatomical landmark detection of helicotrema, oval and round window. A fully automated pipeline with a single, dual-headed volumetric 3D U-Net was implemented, trained and evaluated using manually labeled in-house datasets from cadaveric specimen ([Formula: see text]) and clinical practice ([Formula: see text]). The model robustness was further evaluated on three independent open-source datasets ([Formula: see text] scans) consisting of cadaveric specimen scans. For the in-house datasets, Dice scores of [Formula: see text], intersection-over-union scores of [Formula: see text] and average Hausdorff distances of [Formula: see text] and [Formula: see text] voxel units were achieved. The landmark localization task was performed automatically with an average localization error of [Formula: see text] voxel units. A robust, albeit reduced performance could be attained for the catalogue of three open-source datasets. Results of the ablation studies with 43 mono-parametric variations of the basal architecture and training protocol provided task-optimal parameters for both categories. Ablation studies against single-task variants of the basal architecture showed a clear performance benefit of coupling landmark localization with segmentation and a dataset-dependent performance impact on segmentation ability.


Subject(s)
Deep Learning , Ear, Inner , Humans , Ear, Inner/diagnostic imaging , Cadaver , Image Processing, Computer-Assisted/methods
12.
J Imaging ; 8(2)2022 Feb 02.
Article in English | MEDLINE | ID: mdl-35200739

ABSTRACT

Holotomography is an extension of computed tomography where samples with low X-ray absorption can be investigated with higher contrast. In order to achieve this, the imaging system must yield an optical resolution of a few micrometers or less, which reduces the measurement area (field of view = FOV) to a few mm at most. If the sample size, however, exceeds the field of view (called local tomography or region of interest = ROI CT), filter problems arise during the CT reconstruction and phase retrieval in holotomography. In this paper, we will first investigate the practical impact of these filter problems and discuss approximate solutions. Secondly, we will investigate the effectiveness of a technique we call "multiscalar holotomography", where, in addition to the ROI CT, a lower resolution non-ROI CT measurement is recorded. This is used to avoid the filter problems while simultaneously reconstructing a larger part of the sample, albeit with a lower resolution in the additional area.

13.
Front Surg ; 9: 747517, 2022.
Article in English | MEDLINE | ID: mdl-35187054

ABSTRACT

Improved radiological examinations with newly developed 3D models may increase understanding of Meniere's disease (MD). The morphology and course of the vestibular aqueduct (VA) in the temporal bone might be related to the severity of MD. The presented study explored, if the VA of MD and non-MD patients can be grouped relative to its angle to the semicircular canals (SCC) and length using a 3D model. Scans of temporal bone specimens (TBS) were performed using micro-CT and micro flat panel volume computed tomography (mfpVCT). Furthermore, scans were carried out in patients and TBS by computed tomography (CT). The angle between the VA and the three SCC, as well as the length of the VA were measured. From these data, a 3D model was constructed to develop the vestibular aqueduct score (VAS). Using different imaging modalities it was demonstrated that angle measurements of the VA are reliable and can be effectively used for detailed diagnostic investigation. To test the clinical relevance, the VAS was applied on MD and on non-MD patients. Length and angle values from MD patients differed from non-MD patients. In MD patients, significantly higher numbers of VAs could be assigned to a distinct group of the VAS. In addition, it was tested, whether the outcome of a treatment option for MD can be correlated to the VAS.

14.
Cochlear Implants Int ; 23(1): 32-42, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34519256

ABSTRACT

OBJECTIVE: There is still a lack in precise postoperative evaluation of the cochlea because of strong artifacts. This study aimed to improve accuracy of postoperative two-turn (2TL) and cochlear duct length (CDL) measurements by applying flat-panel volume computed tomography (fpVCT), secondary reconstruction (fpVCTSECO) and three-dimensional curved multiplanar reconstruction. METHODS: First, 10 temporal bone specimens with or without electrode were measured in multi-slice computed tomography (MSCT), fpVCT and fpVCTSECO and compared to high-resolution micro-CT scans. Later, pre- and postoperative scans of 10 patients were analyzed in a clinical setting. RESULTS: Concerning 2TL, no statistically significant difference was observed between implanted fpVCTSECO and nonimplanted micro-CT in 10 temporal bone specimens. In contrast, there was a significant discrepancy for CDL (difference: -0.7 mm, P = 0.004). Nevertheless, there were no clinically unacceptable errors (±1.5 mm). These results could be confirmed in a clinical setting. Using fpVCTSECO, CDL was slightly underestimated postoperatively (difference: -0.5 mm, P = 0.002) but without any clinically unacceptable errors. CONCLUSION: fpVCTSECO can be successfully applied for a precise measurement of the cochlear lengths pre- and postoperatively. However, users must be aware of a slight systematic underestimation of CDL postoperatively. These results may help to refine electrode selection and frequency mapping.


Subject(s)
Cochlear Implantation , Cochlear Implants , Cochlea/diagnostic imaging , Cochlea/surgery , Cochlear Duct/surgery , Cochlear Implantation/methods , Cone-Beam Computed Tomography , Humans , Temporal Bone/diagnostic imaging , Temporal Bone/surgery
15.
J Mech Behav Biomed Mater ; 116: 104330, 2021 04.
Article in English | MEDLINE | ID: mdl-33516129

ABSTRACT

OBJECTIVE: This study evaluates the effect of dynamic-loading on the microgap of the IAC when different supratructure heights are applied. MATERIALS AND METHODS: Forty-eight dental implants (24 each of butt-joint (H) and internal-conical connections (C)) were tested in this study. Each group was further divided into three groups (n = 8) according to the applied suprastructure height (H1, C1: 10 mm, H2, C2: 14 mm and H3, C3: 18 mm). All specimens were subjected to cyclic loading in a chewing-simulator with a load of 98 N for 5 × 106 chewing cycles. The microgap at the IAC was inspected before and after loading, using synchrotron-based micro computed tomography (SRµCT) and light microscopy (LM). RESULTS: SRµCT revealed an internal microgap range between 0.26 µm and 0.5 µm in the group C, whereas the group H exhibited a microgap range between 0.26 µm and 0.47 µm prior to loading. After chewing simulation, a smaller microgap size in all groups was detected ranging from 0.11 µm to 0.26 µm (group C: 0.11µm-0.26 µm; group H: 0.21µm-0.25 µm). The LM investigation showed mean microgap values at the outer IAC junction before loading from 5.8 µm to 11.3 µm and from 3.9 µm to 7.2 µm after loading. All specimens exhibited a vertical intrusion displacement of the abutment. CONCLUSION: Regardless of the crown height, the microgap between the abutment and implant systematically decreased after loading in both butt-joint and internal-conical connections.


Subject(s)
Dental Implants , Synchrotrons , Crowns , Dental Stress Analysis , Mastication , Materials Testing , Muscle Fatigue , X-Ray Microtomography
16.
Carbohydr Polym ; 254: 117406, 2021 Feb 15.
Article in English | MEDLINE | ID: mdl-33357893

ABSTRACT

Cellulosic nanomaterials are in the focus of academia and industry to realize light-weight biobased materials with remarkable strength. While the effect is well known, the distribution of these nanomaterials are less explored, particularly for paper sheets. Here, we explore the 3D distribution of micro and nanosized cellulosic particles in paper sheets and correlate their extent of fibrillation to the distribution inside the sheets and subsequently to paper properties. To overcome challenges with contrast between the particles and the matrix, we attached probes on the cellulose nano/microparticles, either by covalent attachment of fluorescent dyes or by physical deposition of cobalt ferrite nanoparticles. The increased contrast enabled visualization of the micro and nanosized particles inside the paper matrix using multiphoton microscopy, X-ray microtomography and SEM-EDX. The results indicate that fibrillary fines enrich at pores and fiber-fiber junctions, thereby increasing the relative bonded area between fibers to enhance paper strength while CNF seems to additionally form an inner 3D network.


Subject(s)
Biocompatible Materials/chemistry , Cellulose/chemistry , Microscopy, Fluorescence, Multiphoton/methods , Nanofibers/chemistry , Nanoparticles/chemistry , Paper , Staining and Labeling/methods , Fluorescent Dyes/chemistry , Microscopy, Electron, Scanning , Porosity , Spectrometry, X-Ray Emission , Tensile Strength , X-Ray Microtomography
17.
Otol Neurotol ; 42(3): e294-e303, 2021 03 01.
Article in English | MEDLINE | ID: mdl-33555750

ABSTRACT

HYPOTHESIS: Flat-panel volume computed tomography (fpVCT) and secondary reconstruction allow for more accurate measurements of two-turn length (2TL), cochlear duct length (CDL), and angular length (AL). BACKGROUND: Cochlear geometry is a controversially debated topic. In the meantime, there are many different studies partly reporting highly divergent values. Our aim is to discuss the differences and to propose a radiological possibility to improve cochlear measurements using 3D-curved multiplanar reconstruction and fpVCT. METHODS: Performing different image modalities and settings, we tried to find a clinically usable option that allows for a high degree of accuracy. Therefore, we tested them against reference values of high-definition micro-computed tomography. RESULTS: Comparison of 99 µm slice thickness secondary reconstruction of fpVCT and reference showed no significant differences for 2TL and CDL (p ≥ 0.05). Accordingly, ICC (intraclass correlation) values were excellent (ICC ≥ 0.75; lower limit of confidence interval [CI] ≥ 0.75; Cronbach's alpha [α] ≥ 0.9). Evaluating AL, there was a significant difference (difference: -17.27°; p = 0.002). The lower limit of the CI of the ICC was unacceptable (ICC = 0.944; lower limit of CI = 0.248; α = 0.990). Regarding the Bland-Altman plots, there were no clinically unacceptable errors, but a systematic underestimation of AL. CONCLUSION: Secondary reconstruction is a suitable tool for producing reliable data that allow the accurate measurement of 2TL and CDL. The option of generating these reconstructions from raw data limits the need for higher radiation doses. Nevertheless, there is an underestimation of AL using secondary reconstructions.


Subject(s)
Cochlea , Cochlear Duct , Cochlea/diagnostic imaging , Cone-Beam Computed Tomography , Humans , X-Ray Microtomography
18.
Tissue Eng Part C Methods ; 25(6): 367-379, 2019 06.
Article in English | MEDLINE | ID: mdl-31119986

ABSTRACT

IMPACT STATEMENT: Melt electrowriting is an AM technology that bridges the gap between solution electrospinning and melt microextrusion technologies. It can be applied to biomaterials and tissue engineering by making a spectrum of scaffolds with various laydown patterns at dimensions not previously studied. Using submicrometer X-ray tomography, a "fingerprint" of porosity for such scaffolds can be obtained and used as an important measure for quality control, to ensure that the scaffold fabricated is the one designed and allows the selection of specific scaffolds based on desired porosities.


Subject(s)
Electrochemistry/methods , Tissue Scaffolds/chemistry , X-Ray Microtomography , Equipment Design , Image Processing, Computer-Assisted , Porosity
19.
Sci Rep ; 9(1): 12627, 2019 09 02.
Article in English | MEDLINE | ID: mdl-31477758

ABSTRACT

Magnetic Particle Imaging (MPI) is a promising new tomographic modality for fast as well as three-dimensional visualization of magnetic material. For anatomical or structural information an additional imaging modality such as computed tomography (CT) is required. In this paper, the first hybrid MPI-CT scanner for multimodal imaging providing simultaneous data acquisition is presented.

20.
Heliyon ; 4(2): e00524, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29560445

ABSTRACT

State-of-the art, two-piece dental implants made from titanium alloys exhibit a complex micromechanical behavior under dynamical load. Its understanding, especially the formation of microgaps, is of crucial importance in order to predict and improve the long-term performance of such implants. Microgap formation in a loaded dental implant with a conical implant-abutment connection can be studied and quantified by synchrotron radiography with micrometer accuracy. Due to the high costs and limited access to synchrotron radiation sources, alternative approaches are needed in order to depict the microgap formation. Therefore, synchrotron radiography is used in this article to validate a simple finite element model of an experimental conical implant design. Once validated, the model is in turn employed to systematically study the microgap formation developed in a variety of static load scenarios and the influence of the preload of abutment screw on the microgap formation. The size of the microgap in finite element analysis (FEA) simulations is consistent with that found in in-vitro experiments. Furthermore, the FE approach gives access to more information such as the von-Mises stresses. It is found that the influence of the abutment screw preload has only a minor effect on the microgap formation and local stress distribution. The congruence between FE simulations and in-vitro measurements at the micrometer scale underlines the validity and relevance of the simple FE method applied to study the micromovement of the abutment and the abutment screw preload in conical implant-abutment connections under load.