Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Vasc Surg ; 67(2): 637-644.e30, 2018 02.
Article in English | MEDLINE | ID: mdl-29389426

ABSTRACT

OBJECTIVE: The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible. METHODS: Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. RESULTS: The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. CONCLUSIONS: Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators.


Subject(s)
Blood Vessel Prosthesis , Device Approval/standards , Endovascular Procedures/instrumentation , Peripheral Arterial Disease/therapy , Registries/standards , Stents , United States Food and Drug Administration/standards , Vascular Surgical Procedures/instrumentation , Data Mining/standards , Electronic Health Records/standards , Endovascular Procedures/adverse effects , Humans , International Cooperation , Medical Informatics/standards , Peripheral Arterial Disease/diagnosis , Peripheral Arterial Disease/physiopathology , Product Surveillance, Postmarketing/standards , Prosthesis Design , Randomized Controlled Trials as Topic/standards , Risk Factors , Time Factors , Treatment Outcome , United States/epidemiology , Vascular Surgical Procedures/adverse effects , Workflow
2.
Circ J ; 82(2): 316-322, 2018 01 25.
Article in English | MEDLINE | ID: mdl-29367497

ABSTRACT

BACKGROUND: The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible.Methods and Results:Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. CONCLUSIONS: Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators.


Subject(s)
Equipment and Supplies/standards , Peripheral Arterial Disease , Registries/standards , Epidemiological Monitoring , Humans , Peripheral Arterial Disease/diagnosis , Peripheral Arterial Disease/therapy , Reference Standards
3.
J Vasc Surg ; 54(2): 394-401, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21658885

ABSTRACT

BACKGROUND: A novel self-expanding drug-eluting stent was designed to slowly release everolimus to prevent restenosis following peripheral arterial intervention. The purpose of the first-in-human Superficial Femoral Artery Treatment with Drug-Eluting Stents (STRIDES) trial was to evaluate the safety and efficacy of this device for the treatment of symptomatic superficial femoral and proximal popliteal arterial occlusive disease. METHODS AND RESULTS: One hundred four patients were enrolled at 11 European investigative centers in a prospective, nonrandomized, single-arm trial. The patients had severe symptomatic vascular disease, including a significant proportion of patients with critical limb ischemia (17%), diabetes (39%), and single-vessel outflow (26%). The mean lesion length was 9.0 ± 4.3 cm. Ninety-nine percent of patients were available for 12-month follow-up, including duplex imaging in 90% and arteriography in 83%. Clinical improvement, defined as a sustained decrease in Rutherford-Becker clinical category, was achieved in 80% of patients. Primary patency (freedom from ≥50% in-stent restenosis) was 94 ± 2.3% and 68 ± 4.6% at 6 and 12 months, respectively. Plain radiographic examination of 122 implanted devices at 12 months revealed no evidence for stent fracture. CONCLUSIONS: The everolimus-eluting self-expanding nitinol stent can be successfully implanted in patients with severe peripheral arterial disease with favorable outcomes and clinical improvements observed in the majority of patients.


Subject(s)
Angioplasty/instrumentation , Cardiovascular Agents/administration & dosage , Drug-Eluting Stents , Femoral Artery , Peripheral Arterial Disease/therapy , Popliteal Artery , Sirolimus/analogs & derivatives , Aged , Angioplasty/adverse effects , Ankle Brachial Index , Constriction, Pathologic , Europe , Everolimus , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Humans , Kaplan-Meier Estimate , Limb Salvage , Male , Middle Aged , Peripheral Arterial Disease/diagnosis , Peripheral Arterial Disease/physiopathology , Popliteal Artery/diagnostic imaging , Popliteal Artery/physiopathology , Prospective Studies , Prosthesis Design , Radiography , Severity of Illness Index , Sirolimus/administration & dosage , Time Factors , Treatment Outcome , Ultrasonography, Doppler, Duplex , Vascular Patency
4.
Am J Cardiol ; 99(10): 1403-8, 2007 May 15.
Article in English | MEDLINE | ID: mdl-17493469

ABSTRACT

The ZoMaxx Coronary Stent System elutes the antiproliferative agent zotarolimus via a biocompatible phosphorylcholine polymer loaded onto a novel, thin, stainless steel stent platform containing an 0.0007-inch inner layer of tantalum that enhances fluoroscopic radiopacity. The objective of this single-arm prospective clinical trial was to assess the safety and performance of the ZoMaxx stent for the treatment of coronary artery stenosis. Forty consecutive patients with ischemic coronary occlusive disease due to single de novo obstructive lesions of native coronary arteries were treated with 3 x 18 mm ZoMaxx stents at the Dante Pazzanese de Cardiologie in Saõ Paulo, Brazil, between April and July 2005. Independent core laboratories analyzed quantitative coronary angiography and intravascular ultrasound results immediately after stent implantation, and after 4 months. The lesion, procedure, and device-deployment success rates were all 100% (40 of 40). There were no major adverse cardiac events during the study. Follow-up quantitative coronary angiography at 4 months revealed in-stent and in-segment late lumen losses of 0.20 +/- 0.35 and 0.17 +/- 0.35 mm, respectively. Follow-up intravascular ultrasound at 4 months revealed 6.5 +/- 6.2% neointimal volume obstruction. There were no instances of late acquired stent incomplete apposition or stent thrombosis. In conclusion, the ZoMaxx Coronary Stent can be safely implanted for the treatment of de novo coronary artery stenosis. The inhibition of neointima formation as measured by follow-up angiography and IVUS after 4 months suggests therapeutic potential for the reduction of restenosis.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/therapeutic use , Coronary Stenosis/therapy , Phosphorylcholine/therapeutic use , Sirolimus/analogs & derivatives , Stents , Aged , Blood Vessel Prosthesis Implantation , Coronary Angiography , Coronary Circulation , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Stenosis/diagnostic imaging , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Design , Research Design , Sirolimus/chemistry , Sirolimus/pharmacology , Sirolimus/therapeutic use , Treatment Outcome , Tunica Intima/diagnostic imaging , Tunica Intima/physiopathology , Ultrasonography, Interventional
5.
Am. j. cardiol ; 99(10): 1403-1408, May 2007. ilus
Article in English | SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1059491

ABSTRACT

The ZoMaxx Coronary Stent System elutes the antiproliferative agent zotarolimus via a biocompatible phosphorylcholine polymer loaded onto a novel, thin, stainless steel stent platform containing an 0.0007-inch inner layer of tantalum that enhances fluoroscopic radiopacity. The objective of this single-arm prospective clinical trial was to assess the safety and performance of the ZoMaxx stent for the treatment of coronary artery stenosis. Forty consecutive patients with ischemic coronary occlusive disease due to single de novo obstructive lesions of native coronary arteries were treated with 3 x 18 mm ZoMaxx stents at the Dante Pazzanese de Cardiologie in Saõ Paulo, Brazil, between April and July 2005. Independent core laboratories analyzed quantitative coronary angiography and intravascular ultrasound results immediately after stent implantation, and after 4 months. The lesion, procedure, and device-deployment success rates were all 100% (40 of 40). There were no major adverse cardiac events during the study. Follow-up quantitative coronary angiography at 4 months revealed in-stent and in-segment late lumen losses of 0.20 +/- 0.35 and 0.17 +/- 0.35 mm, respectively. Follow-up intravascular ultrasound at 4 months revealed 6.5 +/- 6.2% neointimal volume obstruction. There were no instances of late acquired stent incomplete apposition or stent thrombosis. In conclusion, the ZoMaxx Coronary Stent can be safely implanted for the treatment of de novo coronary artery stenosis. The inhibition of neointima formation as measured by follow-up angiography and IVUS after 4 months suggests therapeutic potential for the reduction of restenosis.


Subject(s)
Coronary Angiography , Angioplasty, Balloon, Coronary/instrumentation , Cardiotonic Agents/therapeutic use , Coronary Circulation , Prosthesis Design , Phosphorylcholine/therapeutic use , Blood Vessel Prosthesis Implantation , Epidemiologic Research Design , Coronary Restenosis , Coronary Restenosis/etiology , Sirolimus/analogs & derivatives , Sirolimus/pharmacology , Sirolimus/chemistry , Sirolimus/therapeutic use , Stents , Tunica Intima , Tunica Intima/physiopathology
SELECTION OF CITATIONS