Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Anal Bioanal Chem ; 416(5): 1105-1115, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38189917

ABSTRACT

Acetamiprid (ACE) is a highly effective broad-spectrum insecticide, and its widespread use is potentially harmful to human health and environmental safety. In this study, magnetic Fe3O4/carbon (Fe3O4/C), a derivative of metal-organic framework MIL-101 (Fe), was synthesized by a two-step calcination method. And a fluorescent sensing strategy was developed for the efficient and sensitive detection of ACE using Fe3O4/C and multiple complementary single-stranded DNA (ssDNA). By using aptamer with multiple complementary ssDNA, the immunity of interference of the aptasensor was improved, and the aptasensor showed high selectivity and sensitivity. When ACE was present, the aptamer (Apt) combined with ACE. The complementary strand of Apt (Cs1) combined with two short complementary strands of Cs1, fluorophore 6-carboxyfluorescein-labeled complementary strand (Cs2-FAM) and the other strand Cs3. The three strands formed a double-stranded structure, and fluorescence would not be quenched by Fe3O4/C. In the absence of ACE, Cs2-FAM would be in a single-chain state and would be adsorbed by Fe3O4/C, and the fluorescence of FAM would be quenched by Fe3O4/C via photoelectron transfer. This aptasensor sensitively detected ACE over a linear concentration range of 10-1000 nM with a limit of detection of 3.41 nM. The recoveries of ACE spiked in cabbage and celery samples ranged from 89.49% to 110.76% with high accuracy.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Humans , DNA, Single-Stranded , Vegetables , Neonicotinoids , Fluorescence , Aptamers, Nucleotide/chemistry , Biosensing Techniques/methods , Limit of Detection
2.
J Hazard Mater ; 476: 134935, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38905980

ABSTRACT

Time-resolved fluorescent lateral immunoassay strip (TRFLIS) is a reliable and rapid method for detecting acetamiprid. However, its sensitivity is often affected by the structural patterns and stability of the fluorescent probe. Researchers have shown significant interests in using goat anti-mouse IgG (GaMIgG) which is indirectly bound to time-resolved fluorescent microsphere (TRFM) and antibody. This allowed for oriented modification of the antibody. However, the stability of fluorescent probe in this binding mode remained unexplored. Herein, 1-ethyl-(3-dimethylaminopropyl) carbodiimide hydrochloride was innovatively used as a cross-linking agent to enhance the binding of antibody to GaMIgG, which improved the stability of the fluorescent probe. Under optimal working conditions, this strategy exhibited a wide linear response range of 5-700 ng/mL. Its limit of detection (LOD) was 0.62 ng/mL, the visual LOD was 5 ng/mL, and the limit of quantification (LOQ) of 2.06 ng/mL. Additionally, under tomato matrix, leek matrix and Chinese cabbage matrix, the linear response ranges were 5-400, 5-300, and 5-700 ng/mL, with LODs of 0.16, 0.60, and 0.41 ng/mL, with LOQs of 0.53, 2.01 and 1.37 ng/mL, respectively. In conclusion, this strategy effectively reduced the dosage of acetamiprid antibody compared with TRFM directly linking acetamiprid antibody, and greatly increased the sensitivity of TRFLIS. Meanwhile, it demonstrated outstanding specificity and accuracy in acetamiprid detection and had been successfully applied to vegetable samples. This method enables rapid and accurate detection of large-volume samples by combining qualitative and quantitative methods. As such, it has great potential in the development of low-cost and high-performance immunochromatographic platforms.

3.
J Hazard Mater ; 477: 135296, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39059293

ABSTRACT

A lateral flow immunoassay strip (LFIAS) is one of the most frequently rapid test technologies for carbofuran (CAR). Nevertheless, the LFIAS has a poor quantitative capability and low sensitivity. And, it also requires often complex sample handling steps, making testing time longer. In this study, Fe3O4 nanoparticles were successively modified with MIL-100(Fe)-based metal-organic framework (MOF) and chloroplatinic acid hexahydrate to obtain a core-shell complex of Fe3O4-MOF-Pt. The complex had a peroxidase-mimicking activity catalytic function that enabled signal amplification and sensitivity enhancement. Upon coupling with carbofuran monoclonal antibody (CAR-mAb), the magnetic separation properties of the probe enabled target-specific enrichment. The LFIAS based on Fe3O4-MOF-Pt nanocomposites could detect CAR in the range of 0.25-50 ng mL-1 with a limit of detection (LOD) of 0.15 ng mL-1, enabling colorimetric and catalytic analysis. In addition, the method showed high specificity and stability for detecting CAR in various vegetables, and recovery rates of the spiked samples were 91.40%-102.40%. In conclusion, this study provided one-stop detection of "target enrichment-visual inspection". While lowering the LOD, it reduced the detection time and improved the detection efficiency. The multifunctional Fe3O4-MOF-Pt nanocomposite provides an idea for the construction of novel multifunctional probes to improve the detection performance of conventional LFIAS.

4.
Talanta ; 269: 125508, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38070284

ABSTRACT

Penicillin antibiotics (PENs) play an important role in killing pathogenic bacteria. However, the residues of various penicillin antibiotics in milk gradually accumulate in the human body with the increase of milk intake, which causes direct harm to the human body. Aptamers can be used as recognition element of sensors. It is great significance to use broad-spectrum aptamers for simultaneous detection of PENs. In this study, we reported the screening and identification of DNA aptamers for PENs. The aptamers were screened by graphene oxide-systematic evolution of ligands by exponential enrichment (GO-SELEX). The broad-spectrum aptamers with high affinity and specificity were successfully obtained after 13 rounds of screening. The affinity and specificity of candidate aptamers were analyzed by a GO fluorescence competition method. Further sequence analysis revealed that a truncated 47 nt aptamer (P-11-1) had a higher affinity than the original 79 nt aptamer. The truncated aptamer P-11-1 was used as a recognition element, and an electrochemical aptasensor was prepared using gold nanoparticles (AuNPs) combined with ferroferric oxide-multi walled carbon nanotube (Fe3O4-MWCNTs) complex. The results showed that the developed aptasensor achieved the simultaneous detection of PENs in milk samples across a concentration range of 2 nM-10,000 nM, achieving a limit of detection of 0.667 nM. This methodology provided a simple and sensitive new thinking for antibiotic multi-residue detection.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Metal Nanoparticles , Humans , Animals , Milk/chemistry , Penicillins/analysis , Gold/chemistry , Metal Nanoparticles/chemistry , Aptamers, Nucleotide/chemistry , SELEX Aptamer Technique/methods , Biosensing Techniques/methods , Limit of Detection
SELECTION OF CITATIONS
SEARCH DETAIL