Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Opt Express ; 32(8): 14521-14531, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38859394

ABSTRACT

A topological photonic crystal InGaAsP/InP core-shell nanowire array laser with bulk states operating in the 1550 nm band is proposed and simulated. By optimizing the structure parameters, high Q factor of 1.2 × 105 and side-mode suppression ratio of 13.2 dB are obtained, which are 28.6 and 4.6 times that of a uniform nanowire array, respectively. The threshold and maximum output are 17% lower and 613% higher than that of the uniform nanowire array laser, respectively, due to the narrower nanowire slits and stronger optical confinement. In addition, a low beam divergence angle of 2° is obtained due to the topological protection. This work may pave the way for the development of high-output, low-threshold, low-beam-divergence nanolasers.

2.
Opt Express ; 32(1): 652-661, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38175089

ABSTRACT

A Si-based nanowire array photonic-crystal surface-emitting laser based on a flat band is designed and simulated. By introducing an air gap between the nanowire and substrate, the bottom reflectivity is significantly enhanced, resulting in much lower threshold and smaller cutoff diameter. Through adjusting the lattice constant (the distance between neighboring nanowires) and nanowire diameter, a photonic crystal structure with a flat band is achieved, in which strong interaction between light and matter occurs in the flat band mode. For the device with a small size, single-mode lasing is obtained with a side-mode suppression ratio of 21 dB, high quality factor of 3940, low threshold gain of 624 cm-1, and small beam divergency angle of ∼7.5°. This work may pave the way for the development of high-performance Si-based surface-emitting nanolasers and high-density photonic integrated circuits.

3.
Sensors (Basel) ; 24(15)2024 Aug 04.
Article in English | MEDLINE | ID: mdl-39124091

ABSTRACT

A graphene-based tunable polarization conversion metasurface (PCM) was designed and analyzed for the purpose of reducing the radar cross-section (RCS) of array antennas. The metasurface comprises periodic shuttle-shaped metal patches, square-patterned graphene, and inclined grating-patterned graphene. By adjusting the Fermi energy levels of the upper (µ1) and lower (µ2) graphene layers, different states were achieved. In State 1, with µ1 = 0 eV and µ2 = 0.5 eV, the polarization conversion ratio (PCR) exceeded 0.9 in the bandwidths of 1.65-2.19 THz and 2.29-2.45 THz. In State 2, with µ1 = µ2 = 0.5 eV, the PCR was greater than 0.9 in the 1.23-1.85 THz and 2.24-2.60 THz bands. In State 3, with µ1 = µ2 = 1 eV, the PCR exceeded 0.9 in the 2.56-2.75 THz and 3.73-4.05 THz bands. By integrating the PCM with the array antenna, tunable RCS reduction was obtained without affecting the basic radiation functionality of the antenna. In State 1, RCS reduction was greater than 10 dB in the 1.60-2.43 THz and 3.63-3.72 THz frequency ranges. In State 2, the RCS reduction exceeded 10 dB in the 2.07-2.53 THz, 2.78-2.98 THz, and 3.70-3.81 THz bands. In State 3, RCS reduction was greater than 10 dB in the 1.32-1.43 THz, 2.51-2.76 THz, and 3.76-4.13 THz frequency ranges. This polarization conversion metasurface shows significant potential for applications in switchable and tunable antenna RCS reduction.

4.
Sensors (Basel) ; 24(11)2024 May 21.
Article in English | MEDLINE | ID: mdl-38894072

ABSTRACT

The large amount of sampled data in coherent phase-sensitive optical time-domain reflectometry (Φ-OTDR) brings heavy data transmission, processing, and storage burdens. By using the comparator combined with undersampling, we achieve simultaneous reduction of sampling rate and sampling resolution in hardware, thus greatly decreasing the sampled data volume. But this way will inevitably cause the deterioration of detection signal-to-noise ratio (SNR) due to the quantization noise's dramatic increase. To address this problem, denoising the demodulated phase signals using compressed sensing, which exploits the sparsity of spectrally sparse vibration, is proposed, thereby effectively enhancing the detection SNR. In experiments, the comparator with a sampling parameter of 62.5 MS/s and 1 bit successfully captures the 80 MHz beat signal, where the sampled data volume per second is only 7.45 MB. Then, when the piezoelectric transducer's driving voltage is 1 Vpp, 300 mVpp, and 100 mVpp respectively, the SNRs of the reconstructed 200 Hz sinusoidal signals are respectively enhanced by 23.7 dB, 26.1 dB, and 28.7 dB by using compressed sensing. Moreover, multi-frequency vibrations can also be accurately reconstructed with a high SNR. Therefore, the proposed technique can effectively enhance the system's performance while greatly reducing its hardware burden.

5.
Sensors (Basel) ; 24(1)2024 Jan 02.
Article in English | MEDLINE | ID: mdl-38203135

ABSTRACT

Fiber-based flexible sensors have promising application potential in human motion and healthcare monitoring, owing to their merits of being lightweight, flexible, and easy to process. Now, high-performance elastic fiber-based strain sensors with high sensitivity, a large working range, and excellent durability are in great demand. Herein, we have easily and quickly prepared a highly sensitive and durable fiber-based strain sensor by dip coating a highly stretchable polyurethane (PU) elastic fiber in an MXene/waterborne polyurethane (WPU) dispersion solution. Benefiting from the electrostatic repulsion force between the negatively charged WPU and MXene sheets in the mixed solution, very homogeneous and stable MXene/WPU dispersion was successfully obtained, and the interconnected conducting networks were correspondingly formed in a coated MXene/WPU shell layer, which makes the as-prepared strain sensor exhibit a gauge factor of over 960, a large sensing range of over 90%, and a detection limit as low as 0.5% strain. As elastic fiber and mixed solution have the same polymer constitute, and tight bonding of the MXene/WPU conductive composite on PU fibers was achieved, enabling the as-prepared strain sensor to endure over 2500 stretching-releasing cycles and thus show good durability. Full-scale human motion detection was also performed by the strain sensor, and a body posture monitoring, analysis, and correction prototype system were developed via embedding the fiber-based strain sensors into sweaters, strongly indicating great application prospects in exercise, sports, and healthcare.


Subject(s)
Disgust , Nitrites , Transition Elements , Wearable Electronic Devices , Humans , Polyurethanes , Delivery of Health Care
6.
Sensors (Basel) ; 23(20)2023 Oct 20.
Article in English | MEDLINE | ID: mdl-37896707

ABSTRACT

In the domain of optical fiber distributed acoustic sensing, the persistent challenge of extending sensing distances while concurrently improving spatial resolution and frequency response range has been a complex endeavor. The amalgamation of pulse compression and frequency division multiplexing methodologies has provided certain advantages. Nevertheless, this approach is accompanied by the drawback of significant bandwidth utilization and amplified hardware investments. This study introduces an innovative distributed optical fiber acoustic sensing system aimed at optimizing the efficient utilization of spectral resources by combining compressed pulses and frequency division multiplexing. The system continuously injects non-linear frequency modulation detection pulses spanning various frequency ranges. The incorporation of non-uniform frequency division multiplexing augments the vibration frequency response spectrum. Additionally, nonlinear frequency modulation adeptly reduces crosstalk and enhances sidelobe suppression, all while maintaining a favorable signal-to-noise ratio. Consequently, this methodology substantially advances the spatial resolution of the sensing system. Experimental validation encompassed the multiplexing of eight frequencies within a 120 MHz bandwidth. The results illustrate a spatial resolution of approximately 5 m and an expanded frequency response range extending from 1 to 20 kHz across a 16.3 km optical fiber. This achievement not only enhances spectral resource utilization but also reduces hardware costs, making the system even more suitable for practical engineering applications.

7.
Opt Lett ; 47(20): 5401-5404, 2022 Oct 15.
Article in English | MEDLINE | ID: mdl-36240374

ABSTRACT

Topology optimization has been widely adopted in the inverse design of nanophotonic devices due to low computation cost, which unfortunately produces intermediate relative permittivity values that fail to meet fabrication constraints. Additionally, the postprocessing required inevitably increases the complexity of the inverse design. In this Letter, we propose an adaptive projection method for topology optimization, in which a two-level hierarchical hyperbolic tangent projection function with linear increment and differentiation is constructed and applied to eliminate inherent defects of conventional topology optimization. Two binarized nanophotonic devices have been designed by our adaptive projection method, among which one ultra-compact dual 90°-bend waveguide reduces the average insertion loss to 20.3% of its similar counterpart and shows an 8.1% reduction for the average crosstalk in the O band, the other ultralow-loss waveguide crossing features an average insertion loss as low as 0.09 dB. With the significant advantages of excellent performance guarantee and fabrication-friendly geometry control fully demonstrated, our inverse design solution shows potential to contribute to nanophotonic devices and integrated chips.

8.
Opt Express ; 29(3): 3694-3707, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33770964

ABSTRACT

We present an ultrasensitive enhanced fabrication-tolerance refractometer utilizing the polarimetric interference of a tapered PANDA-air-hole fiber (PAHF). To obtain high birefringence and unique group birefringence, the PAHF is specially designed by introducing double air holes into the cladding. Ultrahigh sensitivity can be achieved by reducing the group birefringence difference to zero, defined as birefringent dispersion turning point (BDTP). By modifying the diameter of PAHF, the birefringent dispersion can be effectively manipulated to reduce the group birefringence difference. In this way, the workable diameter range for realizing the ultrahigh sensitivity is twice as large as that of conventional microfibers. Additionally, the ultrasensitive wavelength band is dramatically expanded by at least 600 nm, enabling a compact structure and a flexible fiber-length design. Due to the tunable dispersion optimization, the distinctive properties of ultrahigh sensitivity, enhanced fabrication tolerance, and broadband operation can be achieved. We experimentally verified the ultrahigh refractive index sensitivity of 47223 nm/RIU around the BDTP, and the experimental results matched well with the simulations.

9.
BMC Oral Health ; 21(1): 423, 2021 08 30.
Article in English | MEDLINE | ID: mdl-34461866

ABSTRACT

BACKGROUND: The objective of this report was to highlight the importance of using a dental operating microscope (DOM) to locate supernumerary canals and diagnose variations in root canals using cone-beam computed tomographic (CBCT) images. CASE PRESENTATION: A 35-year-old Chinese female had repeated swelling in the upper right posterior maxilla for 3 months and was referred to evaluate symptomatic apical periodontitis and mesotaurodonts for upper right first permanent molar and upper right second permanent molar. Root canal therapy was proposed and conducted with the use of DOM and CBCT. CONCLUSIONS: Proper diagnosis and careful clinicoradiological examination are necessary, and it is essential to reinforce the knowledge of the rare morphology of root canals for clinicians.


Subject(s)
Dental Pulp Cavity , Tooth Root , Adult , Cone-Beam Computed Tomography , Dental Pulp Cavity/diagnostic imaging , Female , Humans , Maxilla/diagnostic imaging , Molar/diagnostic imaging
10.
ACS Appl Mater Interfaces ; 16(38): 51447-51458, 2024 Sep 25.
Article in English | MEDLINE | ID: mdl-39276126

ABSTRACT

The combination of wearable sensors with machine learning enables intelligent perception in human-machine interaction and healthcare, but achieving high sensitivity and a wide working range in flexible strain sensors for signal acquisition and accurate recognition remains challenging. Herein, we introduced carboxymethyl cellulose (CMC) into a carbon nanotubes (CNTs)/MXene hybrid network, forming tight anchoring among the conductive materials and, thus, bringing enhanced interaction. The silicone-rubber-encapsulated CMC-anchored CNTs/MXene (CCM) strain sensor exhibits an excellent sensitivity (maximum gauge factor up to 71 294), wide working range (200%), ultralow detection limit (0.05%), and outstanding durability (over 10 000 cycles), which is superior to most of the recently reported counterparts also based on a conductive composite film. Moreover, the sensor achieves seamless integration with human skin with the help of a poly(acrylic acid) adhesive layer, successfully obtaining stable and clear waveforms with meaningful profiles from the human body. On this basis, we proposed and realized a novel in-air handwriting recognition method via extracting multiple features of high-quality strain signals assisted by deep neural networks, achieving a high classification accuracy of 98.00 and 94.85% for Arabic numerals and letters, respectively. Our work provides an effective approach for significantly improving strain sensing performance, thereby facilitating innovative applications of flexible sensors.


Subject(s)
Carboxymethylcellulose Sodium , Machine Learning , Nanotubes, Carbon , Wearable Electronic Devices , Nanotubes, Carbon/chemistry , Carboxymethylcellulose Sodium/chemistry , Humans , Handwriting
SELECTION OF CITATIONS
SEARCH DETAIL