BMC Med Imaging ; 24(1): 42, 2024 Feb 13.
Article in English | MEDLINE | ID: mdl-38350842

ABSTRACT

BACKGROUND: Parathyroid glands are important endocrine glands, and the identification of normal parathyroid glands is crucial for their protection. The aim of this study is to explore the sonographic characteristics of normal parathyroid glands and analyze the factors affecting their display. METHODS: Seven hundred three subjects who underwent physical examination at our hospital were included. The number, location, size, morphology, echogenicity and blood flow distribution of parathyroid glands were recorded. The ultrasound characteristics and display rate were also summarized. Meanwhile, shear wave elastography was performed in 50 cases to provide the stiffness measurements, and 26 cases received contrast-enhanced ultrasonography for the assessment of microcirculatory perfusion. Furthermore, we analyzed the factors affecting parathyroid display, including basic information of the subjects and ultrasound features of the thyroid. RESULTS: ① A total of 1038 parathyroid glands were detected, among which, 79.29% were hyperechoic, 20.71% were isoechoic, 88.15% were oval-shaped, and 86.71% had blood flow of grade 0-I. ② 81.79% of the subjects had at least one parathyroid gland detected. ③ The Emean, Emax, PI and AUC of the parathyroid glands were significantly lower than those of the adjacent thyroid tissue (P < 0.05). ④ The display of normal parathyroid glands was related to BMI, thyroid echogenicity and thyroid volume of the subjects (P < 0.05). CONCLUSIONS: Normal parathyroid glands tend to appear as oval-shaped hyperechoic nodules with blood flow of grade 0-I. BMI, thyroid echogenicity and thyroid volume are independent factors affecting the display of parathyroid glands.


Subject(s)
Elasticity Imaging Techniques , Parathyroid Glands , Humans , Parathyroid Glands/diagnostic imaging , Microcirculation , Ultrasonography , Thyroid Gland/diagnostic imaging
2.
Ultrason Imaging ; 46(3): 178-185, 2024 May.
Article in English | MEDLINE | ID: mdl-38622911

ABSTRACT

To evaluate the inter-observer variability and the intra-observer repeatability of pulmonary transit time (PTT) measurement using contrast-enhanced ultrasound (CEUS) in healthy rabbits, and assess the effects of dilution concentration of ultrasound contrast agents (UCAs) on PTT. Thirteen healthy rabbits were selected, and five concentrations UCAs of 1:200, 1:100, 1:50, 1:10, and 1:1 were injected into the right ear vein. Five digital loops were obtained from the apical 4-chamber view. Four sonographers obtained PTT by plotting the TIC of right atrium (RA) and left atrium (LA) at two time points (T1 and T2). The frame counts of the first appearance of UCAs in RA and LA had excellent inter-observer agreement, with intra-class correlations (ICC) of 0.996, 0.988, respectively. The agreement of PTT among four observers was all good at five different concentrations, with an ICC of 0.758-0.873. The reproducibility of PTT obtained by four observers at T1 and T2 was performed well, with ICC of 0.888-0.961. The median inter-observer variability across 13 rabbits was 6.5% and the median variability within 14 days for 4 observers was 1.9%, 1.7%, 2.2%, 1.9%, respectively; The PTT of 13 healthy rabbits is 1.01 ± 0.18 second. The difference of PTT between five concentrations is statistically significant. The PTT obtained by a concentration of 1:200 and 1:100 were higher than that of 1:1, while there were no significantly differences in PTT of a concentration of 1:1, 1:10, and 1:50. PTT measured by CEUS in rabbits is feasible, with excellent inter-observer and intra-observer reliability and reproducibility, and dilution concentration of UCAs influences PTT results.


Subject(s)
Contrast Media , Feasibility Studies , Observer Variation , Ultrasonography , Animals , Rabbits , Reproducibility of Results , Ultrasonography/methods , Sulfur Hexafluoride/pharmacokinetics , Pulmonary Circulation/physiology