Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35
Filter
1.
J Endovasc Ther ; : 15266028231188857, 2023 Jul 29.
Article in English | MEDLINE | ID: mdl-37515412

ABSTRACT

PURPOSE: Long-segment aortic branch dissections have been considered a relative contraindication for fenestrated-branched endovascular aneurysm repair (FB-EVAR). This case report describes a technique of dual-lumen stenting of a fully-dissected superior mesenteric artery (SMA) to preserve patency of the true and false lumens during FB-EVAR. CASE REPORT: A 67-year-old man presented with a 6.0 cm extent III chronic post-dissection thoracoabdominal aortic aneurysm. The patient had highly-complex anatomy including dissection of the entire SMA. The true and false lumens of the dissected SMA were noted to be supplying different branches, requiring preservation of both lumens. The patient underwent a staged physician-modified FB-EVAR. A modified endograft containing 5 fenestrations and 1 branch cuff was introduced and the celiac, true-lumen SMA, and 3 renal arteries were sequentially catheterized using staggered deployment of the modified endograft. The false lumen SMA stent was catheterized via the branch cuff. Molded parallel grafting ("eye-of-the-tiger") technique was used to achieve double D configuration between the true and false lumens of the SMA. CONCLUSION: This case demonstrates feasibility of dual-lumen stenting to incorporate dissected target vessels during FB-EVAR while preserving flow to both the true and false lumens and the second-order branches they supply. CLINICAL IMPACT: We report a novel technique that allows incorporation of branch vessels affected by long segment dissection during fenestrated branched endovascular aortic repairs. This has potential advantage of preserving flow to all secondary branches of the dissected target vessels, while reducing the risk of type Ic endoleak.

2.
Microsurgery ; 43(2): 161-165, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36571830

ABSTRACT

Soft tissue sarcomas treated by extensive surgical resection and adjuvant radiation can lead to large tissue deficits that require free flap repair. Significant radiation can further compromise vessels necessitating novel therapeutic approaches. We describe an 82-year-old man who presented with a posterior thigh sarcoma and underwent wide local tumor resection and immediate reconstruction with a microvascular free flap. Due to radiated recipient vessels, this case required bovine patch angioplasty as a conduit for end to side anastomosis. Initial resection and pathology revealed a large myxofibrosarcoma. Wide local resection and radiotherapy resulted in a large irradiated soft tissue defect of 26 x 15 x 4 cm with exposed, radiation damaged neurovascular structures, and a lack of available regional flap options. The planned free flap, a 30 x 8 cm skin island from the left latissimus dorsi muscle with end-to-side anastomosis to the popliteal artery was complicated by friability of the vessel wall and insufficient perfusion. Given the extent of resection and radiation, there were no alternative recipient vessels present within the field. A bovine pericardial patch angioplasty of 2.5 cm in length was performed to the diseased popliteal vessel and an end to side anastomosis was successfully performed between the thoracodorsal artery and the patch. Improved reperfusion of the free flap was noted immediately following anastomosis indicating completion of the anastomosis of our complicated recipient vessel. During the uncomplicated postoperative course, the flap had good perfusion with Doppler signals present, and incision sites intact at discharge from acute hospitalization. Recurrent sarcomas that have undergone extensive resection and radiotherapy pose significant reconstructive challenges. For defects that require free tissue reconstruction when there are limited options for healthy, recipient vessels, bovine pericardial patch angioplasty may act as a robust conduit for diseased vessels.


Subject(s)
Free Tissue Flaps , Plastic Surgery Procedures , Male , Humans , Adult , Cattle , Animals , Aged, 80 and over , Neoplasm Recurrence, Local , Free Tissue Flaps/blood supply , Angioplasty , Anastomosis, Surgical
3.
J Vasc Surg ; 76(6): 1486-1492, 2022 12.
Article in English | MEDLINE | ID: mdl-35810951

ABSTRACT

OBJECTIVES: Preservation of antegrade flow to the left vertebral artery (LVA) is often achieved by transposition or bypass to the left subclavian artery during zone 2 thoracic endovascular aortic repair. An anomalous LVA (aLVA) originating directly from the aortic arch is a common arch variant with a reported incidence of 4% to 6%. In addition, 6% to 10% of vertebral arteries terminate in a posterior inferior cerebellar artery, increasing the risk of stroke if not revascularized. Few series of aLVA to carotid transposition have been reported. The aim of this study was to evaluate the outcomes of patients who underwent aLVA to carotid transposition for the management of aortic disease. METHODS: A retrospective review of all aLVA-carotid transpositions performed for the management of thoracic aortic dissection or aneurysm at a single center from 2018 to 2021 was performed. The primary outcomes were postoperative stroke and patency of the transposed aLVA. Secondary outcomes were spinal cord ischemia, postoperative cranial nerve injury, and Horner's syndrome. RESULTS: Seventeen patients underwent aLVA to carotid transposition as an adjunct to management of aortic disease during the study period. Most were men (n = 14) and the mean age was 54 ± 16 years. The primary indication for aortic repair was dissection in 10, aneurysm in 6, and Kommerell diverticulum in 1. Nine patients underwent zone 2 thoracic endovascular aortic repair, seven received open total arch repair, and there was one attempted total endovascular arch repair that was aborted owing to unfavorable anatomy. Twelve transpositions were performed before or concomitant with planned aortic repair owing to high-risk cerebrovascular anatomy (three posterior inferior cerebellar artery termination, six dominant aLVA, four intracranial LVA stenosis), and two were performed postoperatively for treatment of type II endoleak. LVA diameter ranged from 2 to 6 mm (mean, 3.3 mm). The mean operative time for transposition was 178 ± 38 minutes, inclusive of left subclavian artery revascularization, and the mean estimated blood loss was 169 ± 188 mL. No patients experienced 30-day postoperative spinal cord ischemia, stroke, or mortality. There were two cases of postoperative hoarseness, presumably owing to recurrent laryngeal nerve palsy, both of which resolved within 4 months. There were no cases of Horner's syndrome. At follow-up (mean, 306 days; range, 6-714 days), all transpositions were patent. CONCLUSIONS: Vertebral-carotid transposition is a safe and effective adjunct in the management of aortic disease with anomalous origin of the LVA.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Diseases , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Horner Syndrome , Spinal Cord Ischemia , Stroke , Male , Humans , Adult , Middle Aged , Aged , Female , Blood Vessel Prosthesis Implantation/adverse effects , Horner Syndrome/etiology , Horner Syndrome/surgery , Stents , Treatment Outcome , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Diseases/surgery , Carotid Artery, Common/diagnostic imaging , Carotid Artery, Common/surgery , Spinal Cord Ischemia/etiology , Retrospective Studies , Stroke/etiology , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aortic Dissection/etiology , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology , Endovascular Procedures/adverse effects
4.
J Vasc Surg ; 76(4): 875-883, 2022 10.
Article in English | MEDLINE | ID: mdl-35697311

ABSTRACT

INTRODUCTION: Emergent endovascular repair of suprarenal (SRAAAs) and thoracoabdominal aortic aneurysms (TAAAs) poses a significant challenge due to the need for branch vessel incorporation, time constraints, and lack of dedicated devices. Techniques to incorporate branch vessels have included parallel grafting, physician-modified endografts, double-barrel/reversed iliac branch device, and in situ fenestration (ISF). This study describes a single-center experience and the associated outcomes when using these techniques for ruptured SRAAAs and TAAAs. METHODS: A retrospective review of patients who underwent endovascular repair of ruptured SRAAAs and TAAAs from July 2014 to March 2021 with branch vessel incorporation was performed. Clinical presentation, intraoperative details, and postoperative outcomes of those who underwent ISF were compared with those who underwent repair using non-ISF techniques. The primary outcome of interest was in-hospital mortality. Secondary outcomes were major adverse events including myocardial infarction, respiratory failure, renal dysfunction, new onset dialysis, bowel ischemia, stroke, and spinal cord ischemia. RESULTS: Forty-two patients underwent endovascular repair for ruptured SRAAAs and TAAAs, 18 of whom underwent ISF repair. Seventy-two percent of ISF patients were hypotensive before surgery, compared with 46% of the patients who underwent repair using non-ISF techniques (physician-modified endografts, parallel grafting, or double-barrel/reversed iliac branch device). The total procedural and fluoroscopy times were similar between the two groups despite a greater mean number of branch vessels incorporated with the ISF technique (3.1 vs 2.2 per patient, P = .015). In-hospital mortality was 19% for all ruptures and 25% for ruptures with hypotension. Compared with the non-ISF group, in-hospital mortality trended lower in the ISF group (11% vs 25%, P = .233), reaching statistical significance when comparing patients who presented with hypotension (8% vs 45%, P = .048). The rate of major adverse events was 57% across all techniques and did not significantly differ between the ISF and non-ISF groups, with postoperative renal dysfunction being the most frequent complication (48%). Overall, ISF became the most commonly used technique later in the study period. CONCLUSIONS: Although emergent endovascular repair of ruptured SRAAAs/TAAAs remains a challenge, a number of techniques are available for expeditious treatment. In this series, ISF was associated improve survival, including a fivefold reduction in mortality in patients presenting with hypotension, and has now become the dominant technique at our center. Despite these advantages, postoperative complications and reinterventions are common. Further experience and longer-term follow-up are needed to validate these initial results and assess durability.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Rupture , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Hypotension , Kidney Diseases , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Rupture/complications , Aortic Rupture/diagnostic imaging , Aortic Rupture/surgery , Blood Vessel Prosthesis/adverse effects , Humans , Hypotension/etiology , Kidney Diseases/etiology , Postoperative Complications , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome
5.
Ann Vasc Surg ; 82: 104-111, 2022 May.
Article in English | MEDLINE | ID: mdl-34933106

ABSTRACT

BACKGROUND: Concomitant iliac artery aneurysms can pose challenges during repair of complex abdominal and thoracoabdominal aortic aneurysms. In fenestrated aortic aneurysm repairs (FEVAR), preservation of internal iliac perfusion is important to minimize risk of spinal cord ischemia. Currently, most commonly used fenestrated stent grafts and the only approved iliac branch devices are manufactured by different companies in the United States. We report our experience with combining Iliac Branch Endoprosthesis (IBE) (W.L. Gore and Associates, Flagstaff, AZ) and fenestrated stent grafts, using the Zenith platform (Cook Medical, Bloomington, IN). METHODS: Retrospective review of consecutive patients who underwent FEVAR at a single institution from September, 2015 to June, 2020 was performed. Patients were deemed high-risk for open repair. Fenestrated aortic components implanted were either physician-modified or custom manufactured. Cases in which IBEs were deployed during FEVAR were specifically reviewed. Anatomic details were obtained from preoperative CT scans. Postoperative outcomes such as mortality, technical success, major adverse events, limb patency, limb-related endoleaks and re-intervention rates were assessed. RESULTS: During the study period, 171 patients underwent FEVAR at our institution. Among those, 15 patients had unilateral IBE implantation during FEVAR, while one received bilateral IBE implantation. Fourteen cases involved physician-modified fenestrated endograft, and Zenith Fenestrated (Cook Medical, Bloomington, IN) in combination with Excluder bifurcated main body and IBE (W.L. Gore and Associates, Flagstaff, AZ). Mean operative, and fluoroscopy times were 340.2 minutes, and 65.4 minutes respectively. A total of 67 viscerorenal target vessels (mean = 3.9, range =_3-5) and 15 internal iliac arteries were incorporated, with a mean of 160 cc contrast used. Completion angiograms were free of type 1 and type 3 endoleaks. Technical success was 100%. There was no perioperative mortality. One patient developed spinal cord ischemia post-operative day two with neurological recovery. At mean follow-up of 430 days, overall survival was 100% with no aneurysm-related mortalities. Limb patency remained 100%. There were no type 3 endoleaks while one patient had a type 1B endoleak that is currently being monitored. There was one re-intervention for type 1C renal branch graft endoleak. CONCLUSION: Combining IBE with FEVAR allows internal iliac preservation during endovascular repair of complex abdominal aortic aneurysms, with encouraging early results.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Spinal Cord Ischemia , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/etiology , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Endoleak/etiology , Humans , Prosthesis Design , Spinal Cord Ischemia/etiology , Stents , Time Factors , Treatment Outcome
6.
Ann Vasc Surg ; 79: 72-80, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34644631

ABSTRACT

OBJECTIVE: Patients who present with lower extremity ischemia are frequently anemic and the optimal transfusion threshold for this cohort remains controversial. We sought to evaluate the impact of blood transfusion on postoperative major adverse cardiac events (MACE), including myocardial infarction, dysrhythmia, stroke, congestive heart failure, and 30-day mortality for these patients. METHODS: All consecutive patients who underwent infra-inguinal bypass at our institution from 2011 to 2020 were included. Perioperative red blood cell transfusion was the primary exposure, and the primary outcome was MACE. Univariate and multivariable analyses were performed to assess the impact of patient and procedural variables, including red blood cell transfusion, stratified by hemoglobin (Hgb) nadir: <7, 7-8, and >8 g/dL. RESULTS: Of the 287 patients reviewed for analysis, 146 (50.9%) had a perioperative transfusion (mean: 1.6 ± 3 units). Patients who received a transfusion had a mean nadir Hgb of 8.3 ± 1.0 g/dL, compared to 10.1 ± 1.7 g/dL without a transfusion. The overall incidence of MACE was 15.7% (45 of 287 patients). Univariate analysis demonstrated that MACE was associated with blood transfusion (P = 0.009), lower Hgb nadir (P = 0.02), and higher blood loss (P = 0.003). On multivariate analysis, transfusion was independently associated with MACE for patients with a Hgb nadir >8 g/dL (OR: 3.09; P = 0.006), but not for patients with Hgb nadir 7-8 g/dL (OR: 0.818; P = 0.77). Additionally, patients with MACE had significantly longer length of hospital stay than for patients without (13 vs. 7.7 days, P = 0.001). CONCLUSIONS: For patients undergoing infra-inguinal bypass, receiving a red blood cell transfusion with a Hgb nadir >8 g/dL was associated with a 3-fold increase in MACE, with nearly twice the length of stay. For patients with a Hgb 7-8 g/dL, transfusion did not increase or reduce the incidence of MACE. These findings suggest no benefit of blood transfusion for patients with Hgb nadir >7 g/dL and harm for Hgb >8 g/dL, however causation cannot be proven due to the retrospective nature of the study and randomized studies are needed to confirm or refute these findings.


Subject(s)
Anemia/complications , Cardiovascular Diseases/etiology , Erythrocyte Transfusion/adverse effects , Ischemia/surgery , Perioperative Care , Peripheral Arterial Disease/surgery , Vascular Grafting , Aged , Aged, 80 and over , Anemia/blood , Anemia/diagnosis , Anemia/mortality , Biomarkers/blood , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/mortality , Erythrocyte Transfusion/mortality , Female , Hemoglobins/metabolism , Humans , Ischemia/complications , Ischemia/diagnosis , Ischemia/mortality , Length of Stay , Male , Middle Aged , Perioperative Care/adverse effects , Perioperative Care/mortality , Peripheral Arterial Disease/complications , Peripheral Arterial Disease/diagnosis , Peripheral Arterial Disease/mortality , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Vascular Grafting/adverse effects , Vascular Grafting/mortality
7.
J Vasc Surg ; 74(2S): 93S-100S, 2021 08.
Article in English | MEDLINE | ID: mdl-34303465

ABSTRACT

A publication in the August 2020 issue of the Journal of Vascular Surgery, "Prevalence of unprofessional social media content among young vascular surgeons," brought the concept of professionalism in the vascular surgery community to the forefront. In response to the methodology used in the article, and the definitions of professionalism, a global backlash from health care providers and lay people ensued. The article has since been retracted; however, its publication highlighted the need to reexamine current definitions and philosophies surrounding professionalism in medicine and surgery that may be discriminatory and exclusive. The term professionalism has no standard definition as evidenced by varying definitions among different societies and organizations. The lack of a structured, universally accepted definition of professionalism in the medical and surgical communities has resulted in no standard by which to measure the actions of physicians and surgeons. The definition of professionalism need not be complex and should not vary among specialties and societies. In its most simplistic form, the core definition of "professionalism" embedded in the volumes of publications, guidelines, and charters that exist on the subject of professionalism in medicine is respect. We propose a tiered approach to define professionalism in medicine that builds on fundamental principles of respect and inclusivity, and includes actionable steps at three levels: (1) individual, (2) organizational, and (3) societal. Through this approach, any physician, regardless of specialty, practice type or location, can apply these concepts to ensure they consistently embody what it means to be "professional."


Subject(s)
Cultural Diversity , Physician's Role , Prejudice , Surgeons , Vascular Surgical Procedures , Attitude of Health Personnel , Culturally Competent Care , Female , Gender Equity , Health Knowledge, Attitudes, Practice , Humans , Male , Physicians, Women , Public Opinion , Race Factors , Racism , Sex Factors , Sexism , Social Media
8.
J Vasc Surg ; 73(2): 466-475.e3, 2021 02.
Article in English | MEDLINE | ID: mdl-32622076

ABSTRACT

OBJECTIVE: Revascularization of the left subclavian artery (LSA) during zone 2 thoracic endovascular aortic repair (TEVAR) maintains collateral circulation to decrease ischemic complications, including stroke, spinal cord ischemia, and upper extremity ischemia. Both open surgical and endovascular LSA revascularization techniques have been described, each with unique risks and benefits. We describe our "periscope sandwich" technique for the LSA during zone 2 TEVAR, which maintains antegrade access to the distal abdominal aorta if subsequent interventions are necessary. Technical results and short-term outcomes are compared with LSA open surgical debranching. METHODS: A single-institution retrospective review was performed for patients requiring zone 2 TEVAR with LSA revascularization by periscope sandwich technique or open surgical debranching with subclavian to carotid transposition (SCT) or carotid-subclavian bypass (CSB). The presenting aortic disease and perioperative details were recorded. Intraoperative angiography and postoperative computed tomography images were reviewed for occurrence of endoleak and branch patency. RESULTS: Between January 2013 and December 2018, the LSA was revascularized by periscope sandwich in 18 patients, SCT in 22 patients, and CSB in 13 patients. Compared with open surgical debranching, periscope sandwich had a lower median estimated blood loss (100 mL vs 200 mL for pooled SCT and CSB; P = .03) and lower median case duration (133.5 minutes vs 226 minutes; P < .001). Contrast material volume (120 mL vs 120 mL; P = .98) and fluoroscopy time (13.1 minutes vs 13.3 minutes; P = .92) did not differ significantly between the groups. There was no difference in aorta-related mortality (P = .14), and LSA patency was 100%. Median follow-up for the periscope sandwich group was 11 months, with an overall estimated 91% freedom from gutter leak at 6 months. CONCLUSIONS: LSA periscope sandwich technique provides safe and effective LSA revascularization during zone 2 TEVAR. LSA periscope sandwich can be used emergently with off-the-shelf endovascular components and facilitates future branched-fenestrated endovascular repair of thoracoabdominal aortic diseases.


Subject(s)
Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Subclavian Artery/surgery , Ulcer/surgery , Aged , Aortic Dissection/diagnostic imaging , Aortic Dissection/mortality , Aortic Dissection/physiopathology , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/physiopathology , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Aortic Aneurysm, Thoracic/physiopathology , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Endoleak/etiology , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Graft Occlusion, Vascular/etiology , Humans , Male , Middle Aged , Retrospective Studies , Stents , Subclavian Artery/diagnostic imaging , Subclavian Artery/physiopathology , Time Factors , Treatment Outcome , Ulcer/diagnostic imaging , Ulcer/mortality , Ulcer/physiopathology , Vascular Patency
9.
J Vasc Surg ; 74(4): 1242-1250, 2021 10.
Article in English | MEDLINE | ID: mdl-33845170

ABSTRACT

OBJECTIVE: We investigated the association of tunneling technique on patency and amputation in patients undergoing lower extremity bypass for limb ischemia. METHODS: The National Vascular Quality Initiative database infrainguinal bypass module from 2008 to 2017 was queried for analysis. We excluded cases with non-great saphenous vein grafts, grafts using multiple segments, aneurysmal disease indications, bypass locations outside the femoral to below the knee popliteal artery or tibial arteries, and missing data on tunneling type and limb ischemia. The main exposure variable was the tunneling type, subcutaneously vs subfascially. Our primary outcomes were primary patency and amputation. The secondary outcomes included primary-assisted patency and secondary patency. Univariate and multivariate logistic regression models were used. RESULTS: A total of 5497 bypass patients (2835 subcutaneous and 2662 subfascial) were included. Age, race, graft orientation (reversed vs not reversed), bypass donor and recipient vessels, harvest type, end-stage renal disease, smoking, coronary artery bypass graft, congestive heart failure, P2Y12 inhibitor at discharge, surgical site infection at discharge, and indication (rest pain vs tissue loss vs acute ischemia) were analyzed for an association with the tunneling technique (P < .05). Multivariate analyses demonstrated that the tunneling type was not associated with primary patency, primary-assisted patency, secondary patency, or major amputation (P > .05). CONCLUSIONS: Compared with subfascial tunneling, the superficial tunneling technique was not associated with primary patency or major amputation in limb ischemia patients undergoing infrainguinal bypass with a single-segment great saphenous vein.


Subject(s)
Amputation, Surgical , Ischemia/surgery , Peripheral Arterial Disease/surgery , Saphenous Vein/transplantation , Vascular Grafting , Vascular Patency , Aged , Databases, Factual , Female , Humans , Ischemia/diagnostic imaging , Ischemia/physiopathology , Limb Salvage , Male , Middle Aged , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Progression-Free Survival , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Saphenous Vein/diagnostic imaging , Saphenous Vein/physiopathology , Time Factors , Vascular Grafting/adverse effects
10.
J Vasc Surg ; 73(5): 1513-1524.e2, 2021 05.
Article in English | MEDLINE | ID: mdl-33053415

ABSTRACT

OBJECTIVE: We reviewed the complications associated with perioperative lumbar drain (LD) placement for endovascular aortic repair. METHODS: Patients who had undergone perioperative LD placement for endovascular repair of thoracic and thoracoabdominal aortic pathologies from 2010 to 2019 were reviewed. The primary endpoints were major and minor LD-associated complications. Complications that had resulted in neurological sequelae or had required an intervention or a delay in operation were defined as major. These included intracranial hemorrhage, symptomatic spinal hematoma, cerebrospinal fluid (CSF) leak requiring intervention, meningitis, retained catheter tip, arachnoiditis, and traumatic (or bloody) tap resulting in delayed operation. Minor complications were defined as a bloody tap without a delay in surgery, asymptomatic epidural hematoma, and CSF leak with no intervention required. Isolated headaches were recorded separately owing to the minimal clinical impact. RESULTS: A total of 309 LDs had been placed in 268 consecutive patients for 222 thoracic endovascular aortic repairs, 85 complex endovascular aortic repairs (EVARs; fenestrated branched EVAR/parallel grafting), and 2 EVARs (age, 65 ± 13 years; 71% male) for aortic pathology, including aneurysm (47%), dissection (49%), penetrating aortic ulcer (3%), and traumatic injury (0.6%). A dedicated neurosurgical team performed all LD procedures; most were performed by the same individual, with a technical success rate of 98%. Radiologic guidance was required in 3%. The reasons for unsuccessful placement were body habitus (n = 2) and severe spinal disease (n = 3). Most were placed prophylactically (96%). The overall complication rate was 8.1% (4.2% major and 3.9% minor). Major complications included spinal hematoma with paraplegia in 1 patient, intracranial hemorrhage in 2, meningitis in 2, arachnoiditis in 3, CSF leak requiring a blood patch in 3, bloody tap delaying the operation in 1, and a retained catheter tip in 1 patient. Patients who had undergone previous LD placement had experienced significantly more major LD-related complications (12.2% vs 3%; P = .019). The rate of total LD-associated complications did not differ between prophylactic and emergent therapeutic placements (8.1% vs 7.7%; P = 1.00) nor between major or minor complications. On multivariate analysis, previous LD placement and an overweight body mass index were the only independent predictors of major LD-related complications. CONCLUSIONS: The complications associated with LD placement can be severe even when performed by a dedicated team. Previous LD placement and overweight body mass index were associated with a significantly greater risk of complications; however, emergent therapeutic placement was not. Although these risks are justified for therapeutic LD placement, the benefit of prophylactic LD placement to prevent paraplegia should be weighed against these serious complications.


Subject(s)
Aorta, Thoracic/surgery , Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation , Drainage/adverse effects , Endovascular Procedures , Postoperative Complications/etiology , Aged , Aorta, Thoracic/diagnostic imaging , Aortic Diseases/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Body Mass Index , Databases, Factual , Drainage/instrumentation , Endovascular Procedures/adverse effects , Female , Humans , Lumbar Vertebrae , Male , Middle Aged , Obesity/complications , Obesity/diagnosis , Postoperative Complications/diagnostic imaging , Postoperative Complications/therapy , Retrospective Studies , Risk Assessment , Risk Factors , Treatment Outcome
11.
Ann Vasc Surg ; 76: 244-253, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34186181

ABSTRACT

OBJECTIVES: Endovascular repair of complex abdominal and thoracoabdominal aortic aneurysms have been performed widely in an increasing number of centers, utilizing custom-manufactured or physician-modified stent grafts containing fenestrations and side-arm branches for visceral and renal artery incorporation. Alternatively, inner branch configurations may be useful in complex anatomy, where application of fenestrations or side-arm branches can be challenging. Our study aims to evaluate the incidence of target vessel instability when incorporated with inner branch configurations, and report clinical outcomes of patients who underwent fenestrated/branched endovascular aortic repairs (F-BEVAR) containing one or more inner branches. METHODS: We reviewed patients who underwent F-BEVAR with at least one inner branch configuration for complex abdominal or thoracoabdominal aortic aneurysms at Keck Hospital of University of Southern California from 2014 to 2020. Endpoints were mortality, major adverse events (MAE), technical success, and target vessel instability. Target vessel instability was assessed using follow-up computed tomography (CT) and duplex imaging. RESULTS: Out of the 175 patients who underwent F-BEVAR for complex abdominal and TAAA during the study period, 17 patients had at least one inner branch configuration. All were deemed high-risk for open repair with multiple cardiovascular and/or pulmonary comorbidities. Eight (47%) patients had extent I, II, III thoracoabdominal aortic aneurysms, and 10 (59%) had prior aortic repairs. A total of 68 target vessels were incorporated (mean = 4 vessels/patient, range=1~6), of which 40% were inner branch configurations, most commonly for renal arteries. Technical success was 94.1%. There was one perioperative mortality due to massive myocardial infarction, as well as one patient who needed temporary hemodialysis. No device-related mortalities were observed. At 30 days, primary inner branch patency was 100% with no target vessel instability or reintervention. At mean follow-up of 5.8 months, the overall survival was 94% with one patient who expired from unknown cause. Overall primary inner branch patency was 96.3%, due to occlusion of a long lumbar artery branch with no clinical sequelae. CONCLUSION: Inner branch configurations can provide a safe alternative technique of branch incorporation during complex endovascular aortic repair.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Aortic Aneurysm, Thoracic/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Female , Humans , Male , Postoperative Complications/etiology , Prosthesis Design , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Vascular Patency
12.
Vascular ; 29(5): 652-656, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33183164

ABSTRACT

PURPOSE: There have been increasing number of endovascular aortic aneurysm repair performed in hostile necks using newer generation technology including polymer-based proximal sealing devices such as the Ovation system. Unique design features of the device can pose challenges during endovascular salvage of type 1A endoleak. We describe two cases of successful application of physician-modified fenestrated endografting, in order to repair type 1A endoleaks following endovascular aortic aneurysm repair with ovation system. TECHNIQUE: In both cases, multi-fenestrated endografts were custom-modified using preloaded wire technique on Cook Zenith Alpha thoracic stent grafts at the back table. Under general anesthesia, left brachial cut down and a single percutaneous femoral access were performed. Staggered deployment of fenestrated endograft, accompanied by sequential catheterization of target vessels, facilitated correct alignment of fenestrated endograft. Infolding of fenestrated endograft inside the Ovation main body resulted in leg claudication, and repaired with balloon expandable covered tent. Prophylactic deployment of balloon expandable covered stent was performed in the second case. Both cases showed resolution of type 1A endoleak. CONCLUSION: Fenestrated endovascular repair is feasible for proximal failure of Ovation endografts. Careful planning and advanced skill set in complex endovascular aortic repair are required, as well as detailed knowledge of the failed endografts.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endoleak/therapy , Endovascular Procedures/instrumentation , Polymers/chemistry , Prosthesis Failure , Aged, 80 and over , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/diagnostic imaging , Endoleak/etiology , Endovascular Procedures/adverse effects , Humans , Male , Prosthesis Design , Treatment Outcome
13.
J Vasc Surg ; 72(2): 738-746, 2020 08.
Article in English | MEDLINE | ID: mdl-32273222

ABSTRACT

The Society for Vascular Surgery Lower Extremity Threatened Limb Classification System has been developed to stratify amputation risk on the basis of extent of the wound, level of ischemia, and severity of foot infection (WIfI). However, there are no currently validated metrics to assess, grade, and consider functional status, especially ambulatory status, as a major consideration during limb salvage efforts. Therefore, we propose an adjunct to the current WIfI system to include the patient's ambulatory functional status after initial assessment of limb threat. We propose a functional ambulatory score divided into grade 0, ambulation outside the home with or without an assistive device; grade 1, ambulation within the home with or without an assistive device; grade 2, minimal ambulation, limbs used for transfers; and grade 3, a person who is bed-bound. Adding ambulatory function as a supplementary assessment tool can guide clinical decision making to achieve optimal future functional ambulatory outcome, a patient-centered goal as critical as limb preservation. This adjunct may aid limb preservation teams in rapid, effective communication and clinical decision making after initial WIfI assessment. It may also improve efforts toward patient-centered care and functional ambulatory outcome as a primary objective. We suggest a score of functional ambulatory status should be included in future trials of patients with chronic limb-threatening ischemia.


Subject(s)
Clinical Decision Rules , Clinical Decision-Making , Dependent Ambulation , Ischemia/diagnosis , Mobility Limitation , Peripheral Arterial Disease/diagnosis , Wound Infection/diagnosis , Chronic Disease , Health Status , Humans , Ischemia/physiopathology , Ischemia/therapy , Patient Selection , Peripheral Arterial Disease/physiopathology , Peripheral Arterial Disease/therapy , Predictive Value of Tests , Prognosis , Risk Factors , Severity of Illness Index , Wound Infection/physiopathology , Wound Infection/therapy
14.
J Vasc Surg ; 70(6): 1776-1781, 2019 12.
Article in English | MEDLINE | ID: mdl-31248760

ABSTRACT

OBJECTIVE: Treatment of type B aortic dissections with thoracic endovascular aortic repair (TEVAR) has been adopted in many centers with the goal of covering the proximal entry tear. Coverage of the left subclavian artery (LSCA) is commonly required to achieve a dissection-free proximal seal zone. A novel thoracic single side-branched (TSSB) endograft device offers a potential off-the-shelf option to achieve total endovascular incorporation of LSCA during zone 2 TEVAR. The aim of this study was to determine what percentage of patients with type B aortic dissection who require zone 2 TEVAR meet the anatomical requirements for this device. METHODS: All consecutive patients undergoing TEVAR for type B aortic dissections at a single institution from 2006 to 2016 were evaluated. Three-dimensional centerline reconstruction of preoperative computed tomography angiography was performed to identify the diameter of the aorta, distances between branch vessels, diameter of the target branch vessel, and location of the primary entry tear. Only patients who met criteria for zone 2 TEVAR were included in the analysis. The primary outcome was percentage of patients that meet all anatomical requirements for TSSB. Individual criteria were evaluated independently, and results were stratified by dissection chronicity. RESULTS: Eighty-seven patients who underwent TEVAR for Stanford type B aortic dissections were reviewed. Fifty-seven (66%) would have required zone 2 TEVAR. Indications for TEVAR were malperfusion (12), aneurysm (15), persistent pain (22), rupture (3), uncontrolled hypertension (5), and other (3). Mean follow-up was 19 months (range, 1-72 months). Only 16 of the 57 patients (28%) met all the requirements for anatomic suitability. The primary contributor was that only 49% of patients had sufficient length between arch branches to prevent coverage of a proximal branch. CONCLUSIONS: Although the new TSSB device can allow for a more proximal seal zone and eliminate the need for open aortic arch debranching, only 28% of patients with type B dissection who required zone 2 TEVAR met all the anatomic requirements for this device. Future devices will need to account for the short distance between the left carotid and LSCA to be more broadly applicable.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis , Endovascular Procedures , Aged , Aortic Dissection/classification , Aorta, Thoracic/anatomy & histology , Aortic Aneurysm, Thoracic/classification , Female , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies
15.
Ann Vasc Surg ; 57: 50.e1-50.e8, 2019 May.
Article in English | MEDLINE | ID: mdl-30684607

ABSTRACT

Chronic type B aortic dissections with continued aneurysmal expansion of the thoracoabdominal aorta after the initial thoracic endovascular aortic repair represent a subset of aortic pathology in which staged distal extension to seal additional septal tears can be advantageous. This approach may require incorporation of visceral or renal branches into the distal seal zone, while maintaining the possibility of further distal extension in the future. We describe a novel technique for incorporation of the celiac axis, with a branch stent graft delivered from a transfemoral approach, then lifted cranially to create an antegrade sandwich graft configuration in a 59-year-old male who presented with a complicated type B aortic dissection requiring coverage of the celiac artery. Utilizing the previous thoracic endograft as a platform for sandwich grafting, a self-expanding stent graft was deployed into the celiac artery from a femoral approach. A steerable sheath with an anchoring balloon was used to lift the stent into an up-facing snorkel position, which was subsequently sandwiched with another thoracic stent graft terminating proximal to the superior mesenteric artery. When single visceral or renal branch incorporation is desired, sandwich grafting via a "lift" technique limits the extent of aortic coverage and reduces the number of branch components, without increasing the complexity of additional visceral and renal branch incorporation during future endovascular aortic repair.


Subject(s)
Aorta, Abdominal/surgery , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Aortic Dissection/diagnostic imaging , Aorta, Abdominal/diagnostic imaging , Aorta, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Chronic Disease , Computed Tomography Angiography , Endovascular Procedures/instrumentation , Humans , Male , Middle Aged , Prosthesis Design , Stents , Treatment Outcome
16.
Vasc Med ; 23(6): 549-554, 2018 12.
Article in English | MEDLINE | ID: mdl-30124120

ABSTRACT

An embolic event originating from thrombus on an otherwise un-diseased or minimally diseased proximal artery (Phantom Thrombus) is a rare but significant clinical challenge. All patients from a single center with an imaging defined luminal thrombus with a focal mural attachment site on an artery were evaluated retrospectively. We excluded all patients with underlying anatomic abnormalities of the vessel at the attachment site. Six patients with a mean age of 62.5 years were identified over a 2.5-year period. All patients had completed treatment for or had a current diagnosis of malignancy and none were on antiplatelets or other anticoagulants. Four thrombi originated in the aorta proximal to the renal arteries and one originated distal. One thrombus was found in the common carotid artery and one was in an arterialized vein graft. Mean follow-up was 22 months. None of the patients underwent removal or exclusion of the embolic source. With systemic anticoagulation, four of the phantom thrombi were resolved on imaging within 8 weeks, one resolved after 72 weeks. One phantom thrombus reoccurred after 6 months on reduced anticoagulant dosing. There was one acute and one death in follow-up (26 months). One patient required a partial foot amputation secondary to tissue necrosis from the initial thromboembolic event. Arterial thrombi forming on otherwise normal vessels are a distinct clinical entity. In patients with a phantom thrombus, a strategy of therapeutic anticoagulation for management of the embolic source seems to be safe and effective over both the short and intermediate-term.


Subject(s)
Anticoagulants/administration & dosage , Arteries/diagnostic imaging , Endovascular Procedures/methods , Thrombectomy/methods , Thromboembolism , Thrombosis , Aged , Female , Humans , Male , Middle Aged , Outcome and Process Assessment, Health Care , Patient Care Management/methods , Patient Selection , Thromboembolism/complications , Thromboembolism/diagnosis , Thromboembolism/etiology , Thromboembolism/prevention & control , Thrombosis/diagnosis , Thrombosis/etiology , Thrombosis/therapy
17.
Ann Vasc Surg ; 49: 309.e7-309.e15, 2018 May.
Article in English | MEDLINE | ID: mdl-29518520

ABSTRACT

Endovascular aneurysm repair has become the first-line treatment modality for infrarenal aortic aneurysms. However, obtaining successful long-term results frequently requires reinterventions. Particularly, delayed type 1a endoleaks pose a challenging problem, as they are often associated with proximal extension of the aneurysmal process to juxtarenal or pararenal aortic segments. We describe 2 remedial techniques to repair delayed type 1a endoleak by extending the seal zone to the suprarenal aorta, while incorporating the renal arteries. In the first case, a commercially available fenestrated stent graft was used. Parallel grafting technique was used in the other case. Both cases were technically successful. Follow-up imaging revealed endoleak resolution with patent renal arteries for both patients. In addition, we describe the difference between the 2 techniques, as well as relevant anatomic and device-specific considerations.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endoleak/surgery , Endovascular Procedures/instrumentation , Stents , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Computed Tomography Angiography , Endoleak/diagnostic imaging , Endoleak/etiology , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Humans , Male , Prosthesis Design , Time Factors , Treatment Outcome
18.
Ann Vasc Surg ; 49: 309.e1-309.e6, 2018 May.
Article in English | MEDLINE | ID: mdl-29197608

ABSTRACT

Total endovascular repair of a thoracoabdominal aortic aneurysm (TAAA) in an urgent setting requires an advanced endovascular skill set and an innovative approach. We describe a novel technique of treating a symptomatic Crawford extent 4 TAAA with a combination of multilayered parallel endografting and double-barrel Gore Excluder bifurcated endografts to achieve complete aneurysm exclusion with visceral and bilateral renal artery incorporation. A 75-year-old male presented with a symptomatic 10 cm Crawford extent 4 TAAA. Severe medical comorbidities, including chronic obstructive lung disease and cardiac arrhythmia, as well as prior open infrarenal aortic aneurysm repair made him high risk for an urgent re-do open repair. His previous open infrarenal aortic replacement created a short distance between the lowest renal artery and the flow divider of the aortic graft, which posed a challenge in using a bifurcated aortic endograft as a distal component of the previously described multilayered parallel endografting. Therefore, celiac and superior mesenteric arteries were treated with a multilayered parallel grafting configuration, whereas bilateral renal arteries were incorporated using side-by-side bifurcated modular stent grafts in double-barrel fashion. Contralateral gates served as cuffs for renal artery branch stent grafts, and ipsilateral limbs were deployed within the common iliac arteries. The patient recovered well and was discharged 3 days after repair. Follow-up imaging at 1 month demonstrated patent celiac, superior mesenteric, and bilateral renal artery flow, with no endoleak and stable aneurysm sac. The patient is doing well clinically 1 year after the operation.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/methods , Renal Artery/surgery , Stents , Aged , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortography/methods , Computed Tomography Angiography , Humans , Male , Prosthesis Design , Renal Artery/diagnostic imaging , Treatment Outcome
19.
Yale J Biol Med ; 87(3): 359-71, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25191151

ABSTRACT

Vein graft adaptation to the arterial environment is characterized by loss of venous identity, with reduced Ephrin type-B receptor 4 (Eph-B4) expression but without increased Ephrin-B2 expression. We examined changes of vessel identity of human saphenous veins in a flow circuit in which shear stress could be precisely controlled. Medium circulated at arterial or venous magnitudes of laminar shear stress for 24 hours; histologic, protein, and RNA analyses of vein segments were performed. Vein endothelium remained viable and functional, with platelet endothelial cell adhesion molecule (PECAM)-expressing cells on the luminal surface. Venous Eph-B4 expression diminished (p = .002), Ephrin-B2 expression was not induced (p = .268), and expression of osteopontin (p = .002) was increased with exposure to arterial magnitudes of shear stress. Similar changes were not found in veins placed under venous flow or static conditions. These data show that human saphenous veins remain viable during ex vivo application of shear stress in a bioreactor, without loss of the venous endothelium. Arterial magnitudes of shear stress cause loss of venous identity without gain of arterial identity in human veins perfused ex vivo. Shear stress alone, without immunologic or hormonal influence, is capable of inducing changes in vessel identity and, specifically, loss of venous identity.


Subject(s)
Arteries/physiology , Receptor, EphB4/metabolism , Saphenous Vein/metabolism , Shear Strength , Stress, Mechanical , Adult , Apoptosis , Bioreactors , Endothelial Cells/metabolism , Fluorescent Antibody Technique , Hemorheology , Humans , Models, Biological , Pressure , Tissue Survival
20.
J Vasc Surg ; 58(3): 814-26, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23972249

ABSTRACT

Vascular surgery has seen a revolutionary transformation in its approach to peripheral vascular disease over the last 2 decades, fueled by technological innovation and a willingness by the field to adopt these changes. However, the underlying pathology behind critical limb ischemia and the significant rate of unhealed wounds and secondary amputations despite apparently successful revascularization needs to be addressed. In seeking to improve outcomes, it may be beneficial to examine our approach to vascular disease at the fundamental level of anatomy, the angiosome, to better dictate reperfusion strategies beyond a simple determination of open vs endovascular procedure. We performed a systematic review of the current literature concerning the significance of the angiosome concept in the realm of vascular surgery. The dearth of convincing evidence in the form of prospective trials and large patient populations, and the lack of a consistent, comparable vocabulary to contrast study findings, prevent recommendation of the conceptual model at a wider level for guidance of revascularization attempts. Further well-structured, prospective studies are required as well as emerging imaging strategies, such as indocyanine green dye-based fluorescent angiography or hyperspectral imaging, to allow wider adoption of the angiosome model in vascular operations.


Subject(s)
Extremities/blood supply , Models, Cardiovascular , Peripheral Vascular Diseases/surgery , Vascular Surgical Procedures , Collateral Circulation , Diagnostic Imaging/methods , Hemodynamics , Humans , Peripheral Vascular Diseases/diagnosis , Peripheral Vascular Diseases/physiopathology , Predictive Value of Tests , Regional Blood Flow , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL