Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.410
Filter
Add more filters

Publication year range
1.
Methods ; 228: 1-11, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38759909

ABSTRACT

The necessity of animal-free performance tests for novel ophthalmic formulation screening is challenging. For this, we developed and validated a new device to simulate the dynamics and physical-chemical barriers of the eye for in vitro performance tests of topic ophthalmic formulations. The OphthalMimic is a 3D-printed device with an artificial lacrimal flow, a cul-de-sac area, a support base, and a simulated cornea comprised of a polymeric membrane containing poly-vinyl alcohol 10 % (w/v), gelatin 2.5 % (w/v), and different proportions of mucin and poloxamer, i.e., 1:1 (M1), 1:2 (M2), and 2:1 (M3) w/v, respectively. The support base is designed to move between 0° and 50° to replicate the movement of an eyelid. We challenged the model by testing the residence performance of poloxamer®407 16 % and poloxamer®407 16 % + chitosan 1 % (PLX16CS10) gels containing fluconazole. The test was conducted with a simulated tear flow of 1.0 mL.min-1 for 5 min. The OphthalMimic successfully distinguished PLX16 and PLX16C10 formulations based on their fluconazole drainage (M1: 65 ± 14 % and 27 ± 10 %; M2: 58 ± 6 % and 38 ± 9 %; M3: 56 ± 5 % and 38 ± 18 %). In conclusion, the OphthalMimic is a promising tool for comparing the animal-free performance of ophthalmic formulations.


Subject(s)
Ophthalmic Solutions , Poloxamer , Poloxamer/chemistry , Ophthalmic Solutions/chemistry , Administration, Ophthalmic , Fluconazole/administration & dosage , Printing, Three-Dimensional , Cornea/drug effects , Cornea/metabolism , Animals , Chitosan/chemistry , Animal Testing Alternatives/methods , Tears/chemistry , Humans , Gelatin/chemistry
2.
Methods ; 230: 21-31, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39074539

ABSTRACT

Envisaging to improve the evaluation of ophthalmic drug products while minimizing the need for animal testing, our group developed the OphthalMimic device, a 3D-printed device that incorporates an artificial lacrimal flow, a cul-de-sac area, a moving eyelid, and a surface that interacts effectively with ophthalmic formulations, thereby providing a close representation of human ocular conditions. An important application of such a device would be its use as a platform for dissolution/release tests that closely mimic in vivo conditions. However, the surface that artificially simulates the cornea should have a higher resistance (10 min) than the previously described polymeric films (5 min). For this key assay upgrade, we describe the process of obtaining and thoroughly characterizing a hydrogel-based hybrid membrane to be used as a platform base to simulate the cornea artificially. Also, the OphthalMimic device suffered design improvements to fit the new membrane and incorporate the moving eyelid. The results confirmed the successful synthesis of the hydrogel components. The membrane's water content (86.25 ± 0.35 %) closely mirrored the human cornea (72 to 85 %). Furthermore, morphological analysis supported the membrane's comparability to the natural cornea. Finally, the performance of different formulations was analysed, demonstrating that the device could differentiate their drainage profile through the viscosity of PLX 14 (79 ± 5 %), PLX 16 (72 ± 4 %), and PLX 20 (57 ± 14 %), and mucoadhesion of PLXCS0.5 (69 ± 1 %), PLX16CS1.0 (65 ± 3 %), PLX16CS1.25 (67 ± 3 %), and the solution (97 ± 8 %). In conclusion, using the hydrogel-based hybrid membrane in the OphthalMimic device represents a significant advancement in the field of ophthalmic drug evaluation, providing a valuable platform for dissolution/release tests. Such a platform aligns with the ethical mandate to reduce animal testing and promises to accelerate the development of safer and more effective ophthalmic drugs.


Subject(s)
Hydrogels , Humans , Hydrogels/chemistry , Ophthalmic Solutions/chemistry , Printing, Three-Dimensional , Cornea/drug effects , Cornea/metabolism , Administration, Ophthalmic , Membranes, Artificial
3.
J Cell Mol Med ; 28(16): e70023, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39158533

ABSTRACT

Astragalus polysaccharide-containing 3D-printed scaffold shows great potential in traumatic skin repair. This study aimed to investigate its repairing effect and to combine it with proteomic technology to deeply resolve the related protein expression changes. Thirty SD rats were divided randomly into three groups (n = 10 per group): the sham-operated group, the model group and the scaffold group. Subsequently, we conducted a comparative analysis on trauma blood perfusion, trauma healing rate, histological changes, the expression of the YAP/TAZ signalling pathway and angiogenesis-related factors. Additionally, neonatal skin tissues were collected for proteomic analysis. The blood perfusion volume and wound healing recovery in the scaffold group were better than that in the model group (p < 0.05). The protein expression of STAT3, YAP, TAZ and expression of vascular-related factor A (VEGFA) in the scaffold group was higher than that in the model group (p < 0.05). Proteomic analysis showed that there were 207 differential proteins common to the three groups. Mitochondrial function, immune response, redox response, extracellular gap and ATP metabolic process were the main groups of differential protein changes. Oxidative phosphorylation, metabolic pathway, carbon metabolism, calcium signalling pathway, etc. were the main differential metabolic pathway change groups. Astragalus polysaccharide-containing 3D-printed scaffold had certain reversals of protein disorder. The Astragalus polysaccharide-containing 3D-printed scaffold may promote the VEGFs by activating the YAP/TAZ signalling pathway with the help of STAT3 into the nucleus, accelerating early angiogenesis of the trauma, correcting the protein disorder of the trauma and ultimately realizing the repair of the wound.


Subject(s)
Astragalus Plant , Polysaccharides , Printing, Three-Dimensional , Proteomics , Rats, Sprague-Dawley , Skin , Tissue Scaffolds , Wound Healing , Animals , Wound Healing/drug effects , Proteomics/methods , Polysaccharides/chemistry , Astragalus Plant/chemistry , Tissue Scaffolds/chemistry , Skin/metabolism , Rats , Signal Transduction , Male
4.
J Synchrotron Radiat ; 31(Pt 5): 1285-1292, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39172090

ABSTRACT

One of the most challenging aspects of X-ray research is the delivery of liquid sample flows into the soft X-ray beam. Currently, cylindrical microjets are the most commonly used sample injection systems for soft X-ray liquid spectroscopy. However, they suffer from several drawbacks, such as complicated geometry due to their curved surface. In this study, we propose a novel 3D-printed nozzle design by introducing microscopic flat sheet jets that provide micrometre-thick liquid sheets with high stability, intending to make this technology more widely available to users. Our research is a collaboration between the EuXFEL and MAX IV research facilities. This collaboration aims to develop and refine a 3D-printed flat sheet nozzle design and a versatile jetting platform that is compatible with multiple endstations and measurement techniques. Our flat sheet jet platform improves the stability of the jet and increases its surface area, enabling more precise scanning and differential measurements in X-ray absorption, scattering, and imaging applications. Here, we demonstrate the performance of this new arrangement for a flat sheet jet setup with X-ray photoelectron spectroscopy, photoelectron angular distribution, and soft X-ray absorption spectroscopy experiments performed at the photoemission endstation of the FlexPES beamline at MAX IV Laboratory in Lund, Sweden.

5.
Biotechnol Bioeng ; 2024 Sep 16.
Article in English | MEDLINE | ID: mdl-39279638

ABSTRACT

We report the integration of 3D printing, electrobiofabrication, and protein engineering to create a device that enables near real-time analysis of monoclonal antibody (mAb) titer and quality. 3D printing was used to create the macroscale architecture that can control fluidic contact of a sample with multiple electrodes for replicate measurements. An analysis "chip" was configured as a "snap-in" module for connecting to a 3D printed housing containing fluidic and electronic communication systems. Electrobiofabrication was used to functionalize each electrode by the assembly of a hydrogel interface containing biomolecular recognition and capture proteins. Specifically, an electrochemical thiol oxidation is used to assemble a thiolated polyethylene glycol hydrogel, that in turn is covalently coupled to either a cysteine-tagged protein G that binds the antibody's Fc region or a lectin that binds the glycans of target mAb analytes. We first show the design, assembly, and testing of the hardware device. Then, we show the transition of a step-by-step sensing methodology (e.g., mix, incubate, wash, mix, incubate, wash, measure) into the current method where functionalization, antibody capture, and assessment are performed in situ and in parallel channels. Both titer and glycan analyses were found to be linear with antibody concentration (to 0.2 mg/L). We further found the interfaces could be reused with remarkably similar results. Because the interface assembly and use are simple, rapid, and robust, we suggest this assessment methodology will be widely applicable, including for other biomolecular process development and manufacturing environments.

6.
World J Urol ; 42(1): 130, 2024 Mar 09.
Article in English | MEDLINE | ID: mdl-38460016

ABSTRACT

OBJECTIVE: To explore the parameters influencing intraoperative calculi excretion (ICE) during flexible ureteroscopy lithotripsy (fURL) using in vitro simulation experiments. METHODS: 3D-printed human kidney models were used to simulate the elimination of gravel during fURL. The factors influencing the ICE during fURL were analyzed by comparing the effects of different degrees of hydronephrosis (mild, moderate, and severe), surgical positions (supine and lateral position), ratios of endoscope-sheath diameter (RESD) (0.625, 0.725, and 0.825), gravel sizes (0.50-1.00 mm, 0.25-0.50 mm, and 0.10-0.25 mm), and ureteral access sheaths (UASs) (traditional UAS and negative-pressure UAS) on ICE. RESULTS: The impacts of various UAS, RESD, degree of hydronephrosis, surgical positions, and gravel sizes on ICE were all significant (p < 0.05). We found no evidence of multicollinearity for all the independent variables, and the linear regression equation fitted as ICE ( g / min ) = 0.102 + 0.083 ∗ UAS grade - 0.050 ∗ RESD grade - 0.048 ∗ hydronephrosis grade + 0.065 ∗ position grade - 0.027 ∗ gravel size grade (R2 = 0.569). CONCLUSION: Employing negative-pressure UAS, smaller RESD, milder hydronephrosis, lateral position, and smaller gravel size contribute to improved ICE during fURL. Among them, the adoption of negative-pressure UAS had the most substantial effects.


Subject(s)
Hydronephrosis , Kidney Calculi , Lithotripsy , Ureteral Calculi , Humans , Ureteroscopy , Kidney Calculi/surgery , Ureteroscopes , Ureteral Calculi/surgery
7.
Wound Repair Regen ; 32(3): 229-233, 2024.
Article in English | MEDLINE | ID: mdl-38534045

ABSTRACT

The capability to produce suture material using three-dimensional (3D) printing technology may have applications in remote health facilities where rapid restocking of supplies is not an option. This is a feasibility study evaluating the usability of 3D-printed sutures in the repair of a laceration wound when compared with standard suture material. The 3D-printed suture material was manufactured using a fused deposition modelling 3D printer and nylon 3D printing filament. Study participants were tasked with performing laceration repairs on the pigs' feet, first with 3-0 WeGo nylon suture material, followed by the 3D-printed nylon suture material. Twenty-six participants were enrolled in the study. Survey data demonstrated statistical significance with how well the 3D suture material performed with knot tying, 8.9 versus 7.5 (p = 0.0018). Statistical significance was observed in the 3D-printed suture's ultimate tensile strength when compared to the 3-0 Novafil suture (274.8 vs. 199.8 MPa, p = 0.0096). The 3D-printed suture also demonstrated statistical significance in ultimate extension when compared to commercial 3-0 WeGo nylon suture (49% vs. 37%, p = 0.0215). This study was successful in using 3D printing technology to manufacture suture material and provided insight into its usability when compared to standard suture material.


Subject(s)
Feasibility Studies , Printing, Three-Dimensional , Suture Techniques , Sutures , Tensile Strength , Animals , Swine , Lacerations/surgery , Materials Testing , Nylons , Wound Healing , Humans , Disease Models, Animal
8.
Anal Bioanal Chem ; 416(1): 215-226, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37923939

ABSTRACT

In this work, we are pleased to present for the first time a 3D-printed electrochemical device using a lab-made conductive filament based on graphite (Gr) and polylactic acid (PLA) polymer matrix for the simultaneous detection of amoxicillin (AMX) and paracetamol (PAR). The sensor was properly characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). Compared to the commercial glassy carbon electrode (GCE), the superior performance of the 3D-Gr/PLA electrode was verified with a 3.8-fold more favored charge transfer. A differential pulse voltammetry (DPV) method was proposed providing a linear working range of 4 to 12 µmol L-1 for both analytes and a limit of detection (LOD) of 0.80 and 0.51 µmol L-1 for AMX and PAR, respectively. Additionally, repeatability studies (n = 5, RSD < 5.7%) indicated excellent precision, and recovery percentages ranging from 89 to 109% when applied to synthetic human urine, saliva, and plasma samples, attested to the accuracy of the method. The studies also indicate that the sensor does not suffer significant interference from common substances (antibiotics and biomarkers) present in the biological fluids, which makes it a promising analytical tool considering its low-cost, ease of manufacturing, robustness, and electrochemical performance.


Subject(s)
Acetaminophen , Graphite , Humans , Acetaminophen/chemistry , Amoxicillin , Graphite/chemistry , Electrodes , Polyesters , Printing, Three-Dimensional , Electrochemical Techniques
9.
Environ Res ; 243: 117871, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38086499

ABSTRACT

This work proposes a rigorous mathematical model capable of reproducing the adsorption process in dynamic regime on advanced monoliths geometries. For this, four bed geometries with axisymmetric distribution of channels and similar solid mass were proposed. In each geometry a different distribution of channels was suggested, maintaining constant the bed dimensions of 15 cm high and 5 cm radius. The mathematical modeling includes mass and momentum transfer phenomena, and it was solved with the COMSOL Multiphysics software using mass transfer parameters published in the literature. The overall performance of the column was evaluated in terms of breakthrough (CA/CA0 = 0.1) and saturation times (CA/CA0 = 0.9). The mass and velocity distributions obtained from the proposed model show good physical consistency with what is expected in real systems. In addition, the model proved to be easy to solve given the short convergence times required (2-4 h). Modifications were made to the bed geometry to achieve a better use of the adsorbent material which reached up to 80%. The proposed bed geometries allow obtaining different mixing distributions, in such a way that inside the bed a thinning of the boundary layer is caused, thus reducing diffusive effects at the adsorbent solid-fluid interface, given dissipation rates of about 323 × 10-11 m2/s3. The bed geometry composed of intersecting rings deployed the best performance in terms of usage of the material adsorbent, and acceptable hydrodynamical behavior inside the channels (maximum fluid velocity = 35.4 × 10-5 m/s and drop pressure = 0.19 Pa). Based on these results, it was found that it is possible to reduce diffusional effects and delimit the mass transfer zone inside the monoliths, thus increasing the efficiency of adsorbent fixed beds.


Subject(s)
Environmental Pollutants , Water Pollutants, Chemical , Water Purification , Adsorption , Models, Theoretical , Mathematics , Diffusion
10.
Pathol Int ; 74(7): 379-386, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38712791

ABSTRACT

This paper illustrates a valve-sparing cardiac dissection technique that keeps the atrioventricular and semilunar valves and other important cardiac structures intact. The technique minimizes disruption in heart specimens, so they remain suitable for teaching, demonstration, and further research. When performed following the perfusion-distension method of fixation, as our group previously described, this technique could optimize the preservation of heart specimens for teaching and digital archiving postdissection.


Subject(s)
Dissection , Heart Valves , Humans , Dissection/methods , Heart Valves/pathology , Heart Valves/surgery , Child , Heart/diagnostic imaging , Image Processing, Computer-Assisted/methods
11.
J Nanobiotechnology ; 22(1): 59, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38347563

ABSTRACT

BACKGROUND: Coordination between osteo-/angiogenesis and the osteoimmune microenvironment is essential for effective bone repair with biomaterials. As a highly personalized and precise biomaterial suitable for repairing complex bone defects in clinical practice, it is essential to endow 3D-printed scaffold the above key capabilities. RESULTS: Herein, by introducing xonotlite nanofiber (Ca6(Si6O17) (OH)2, CS) into the 3D-printed silk fibroin/gelatin basal scaffold, a novel bone repair system named SGC was fabricated. It was noted that the incorporation of CS could greatly enhance the chemical and mechanical properties of the scaffold to match the needs of bone regeneration. Besides, benefiting from the addition of CS, SGC scaffolds could accelerate osteo-/angiogenic differentiation of bone mesenchymal stem cells (BMSCs) and meanwhile reprogram macrophages to establish a favorable osteoimmune microenvironment. In vivo experiments further demonstrated that SGC scaffolds could efficiently stimulate bone repair and create a regeneration-friendly osteoimmune microenvironment. Mechanistically, we discovered that SGC scaffolds may achieve immune reprogramming in macrophages through a decrease in the expression of Smad6 and Smad7, both of which participate in the transforming growth factor-ß (TGF-ß) signaling pathway. CONCLUSION: Overall, this study demonstrated the clinical potential of the SGC scaffold due to its favorable pro-osteo-/angiogenic and osteoimmunomodulatory properties. In addition, it is a promising strategy to develop novel bone repair biomaterials by taking osteoinduction and osteoimmune microenvironment remodeling functions into account.


Subject(s)
Calcium Compounds , Nanofibers , Silicates , Tissue Scaffolds , Tissue Scaffolds/chemistry , Hydrogels/pharmacology , Hydrogels/chemistry , Angiogenesis , Bone Regeneration , Biocompatible Materials/pharmacology , Biocompatible Materials/chemistry , Printing, Three-Dimensional , Osteogenesis , Tissue Engineering
12.
Artif Organs ; 2024 Jul 23.
Article in English | MEDLINE | ID: mdl-39041632

ABSTRACT

OBJECTIVES: Engineered Heart Tissue (EHT) is a promising tool to repair heart muscle defects and can additionally be used for drug testing. Due to the absence of an in vitro vascularization, EHT geometry crucially impacts nutrient and oxygen supply by diffusion capacity. We analyzed cardiomyocyte survival in different EHT geometries. METHODS: Different geometries with varying surface-area-to-volume-ratios were calculated (structure A (Ring) AS/V = 58.47 mm2/440 µL3, structure B (Infinity) 25.86 mm2/440 µL3). EHTs were generated from hiPSC-derived cardiomyocytes (4 × 106) and a fibrin/thrombin hydrogel. Cell viability was evaluated by RT-PCR, cytometric studies, and Bioluminescence imaging. RESULTS: Using 3D-printed casting molds, spontaneously beating EHTs can be generated in various geometric forms. At day 7, the RT-PCR analyses showed a significantly higher Troponin-T value in ring EHTs, compared to infinity EHTs. In cytometric studies, we evaluated 15% more Troponin-T positive cells in ring (73% ± 12%), compared to infinity EHTs (58% ± 11%, p = 0.04). BLI visualized significantly higher cell survival in ring EHTs (ROI = A: 1.14 × 106 p/s and B: 8.47 × 105 p/s, p < 0.001) compared to infinity EHTs during longitudinal cultivation process. CONCLUSION: Use of 3D-printing allows the creation of EHTs in all desired geometric shapes. The geometry with an optimized surface-area-to-volume-ratio (ring EHT) demonstrated a significantly higher cell survival measured by RT-PCR, Bioluminescence imaging, and cytometric studies using FACS analysis.

13.
Childs Nerv Syst ; 2024 Sep 02.
Article in English | MEDLINE | ID: mdl-39222090

ABSTRACT

Sphenoid wing dysplasia is a characteristic finding in children with neurofibromatosis type 1 (NF1). Some of these children develop proptosis and vision loss secondary to the spheno-orbital encephalocele. A 6-year-old boy presented to us with complaints of painless progressive uni-ocular vision loss and progressive pulsatile proptosis. Imaging revealed spheno-orbital encephalocele into the orbit through the dysplastic posterior orbital wall. 3D printed customized implant was designed and placed to fit the defect. This prevented further herniation of the temporal lobe into the orbit, leading to reduction of proptosis and improvement in vision of the child.

14.
Orthod Craniofac Res ; 2024 May 27.
Article in English | MEDLINE | ID: mdl-38800926

ABSTRACT

INTRODUCTION: The aim of this in vitro study was to examine the potential impact of different curing times of 3D-printed orthodontic aligners on their cytotoxicity. METHOD: Some 60 samples of aligner material were directly 3D printed using Tera Harz TC-85 DAC resin and randomly allocated to three different curing time groups (14, 24 and 50 min). Zendura FLX samples were used as control. The samples were incubated in saliva for 14 days, and then the supernatant was collected. Human gingival fibroblasts (HGF-1)-CRL2014 were used to evaluate potential cytotoxicity. Furthermore, HGF-1 cells were plated on the samples as well as on a glass control sample. After 72 h of growth, their viability was tested. RESULTS: Compared with the glass, only the 50-min curing time markedly reduced fibroblast cell growth. Additionally, a negative linear trend was observed between curing time and fibroblast growth. In comparison with the aligner control group, all samples, including the aligner control samples, exhibited a significant reduction in the viability of human fibroblasts when exposed to saliva. CONCLUSIONS: 3D directly printed aligners showed a cytotoxic effect similar to that of thermoformed conventional aligners in terms of fibroblasts growth. A linear trend was found between curing time and cells growth, indicating that directly printed aligners could exhibit higher cytotoxicity if exposed to a longer curing time. This dependence on curing time underscores the importance of following a strict manufacturing process.

15.
Eur Spine J ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38713447

ABSTRACT

PURPOSE: The spinopelvic reconstruction poses significant challenges following total sacrectomy in patients with malignant or aggressive benign bone tumours encompassing the entire sacrum. In this study, we aim to assess the functional outcomes and complications of an integrated 3D-printed sacral endoprostheses featuring a self-stabilizing design, eliminating the requirement for supplemental fixation. METHODS: We retrospectively analyzed patients with sacral tumours who underwent total sacrectomy followed by reconstruction with 3D-printed self-stabilizing endoprosthesis. Clinically, we evaluated functional outcomes using the 1993 version of the musculoskeletal tumour society (MSTS-93) score. Perioperative and postoperative complications were also documented. RESULTS: 10 patients met final inclusion criteria. The median age was 49 years (range, 31-64 years). The median follow-up time was 26.5 months (range, 15-47 months). Median postoperative functional MSTS-93 was 22.5 (range, 13-25). The median operation time was 399.5 min (305-576 min), and the median intraoperative blood loss was and 3200 ml (2400-7800 ml). Complications include wound dehiscence in one patient, bowel, bladder, and sexual dysfunction in four patients, cerebrospinal fluid leak in one patient, and tumour recurrence in one patient. There were no mechanical complications related to the endoprosthesis at the last follow-up. CONCLUSION: The utilization of 3D-printed self-stabilizing endoprosthesis proved to be a viable approach, yielding satisfactory short-term outcomes in patients undergoing total sacral reconstruction without supplemental fixation.

16.
BMC Health Serv Res ; 24(1): 28, 2024 Jan 04.
Article in English | MEDLINE | ID: mdl-38178068

ABSTRACT

PURPOSE: To identify the clinical impact and potential benefits of in-house 3D-printed objects through a questionnaire, focusing on three principal areas: patient education; interdisciplinary cooperation; preoperative planning and perioperative execution. MATERIALS AND METHODS: Questionnaires were sent from January 2021 to August 2022. Participants were directed to rate on a scale from 1 to 10. RESULTS: The response rate was 43%. The results of the rated questions are averages. 84% reported using 3D-printed objects in informing the patient about their condition/procedure. Clinician-reported improvement in patient understanding of their procedure/disease was 8.1. The importance of in-house placement was rated 9.2. 96% reported using the 3D model to confer with colleagues. Delay in treatment due to 3D printing lead-time was 1.8. The degree with which preoperative planning was altered was 6.9. The improvement in clinician perceived preoperative confidence was 8.3. The degree with which the scope of the procedure was affected, in regard to invasiveness, was 5.6, wherein a score of 5 is taken to mean unchanged. Reduction in surgical duration was rated 5.7. CONCLUSION: Clinicians report the utilization of 3D printing in surgical specialties improves procedures pre- and intraoperatively, has a potential for increasing patient engagement and insight, and in-house location of a 3D printing center results in improved interdisciplinary cooperation and allows broader access with only minimal delay in treatment due to lead-time.


Subject(s)
Printing, Three-Dimensional , Specialties, Surgical , Humans
17.
Food Microbiol ; 122: 104561, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38839224

ABSTRACT

The current study aimed to determine if the 3D-printing speed and temperature would impact the transferability of foodborne pathogens from the stainless-steel (SS) food cartridge to the 3D-printed food ink. Staphylococcus aureus and Escherichia coli were inoculated onto the interior surface of the SS food cartridges. Subsequently, a model food ink was extruded with a recommended macronutrient contribution of 55.8, 23.7, and 20.5% of carbohydrates, proteins, and fat, respectively. The impact of 3D-printing temperatures and speeds on transfer rates was analysed using a Two-Way ANOVA. S. aureus was transferred more from the cartridge to the food ink with a population of 3.39, 2.98, and 3.09 log CFU/g compared to 2.03, 2.06, and 2.00 log CFU/g for E. coli at 2000, 3000, and 4000 mm/s printing speed, respectively, at 25 °C. A Kruskal-Wallis Test was employed to investigate the effect of different speeds and temperatures on the transferability of S. aureus and E. coli. Speed was the main factor affecting S. aureus transferability, while temperature (25 and 50 °C) had the greatest impact on E. coli transferability. This research seeks to advance the understanding of 3D-printing parameters in pathogen transferability and help the food industry move towards this technology's quick and safe adoption.


Subject(s)
Escherichia coli , Food Microbiology , Printing, Three-Dimensional , Staphylococcus aureus , Temperature , Staphylococcus aureus/growth & development , Escherichia coli/growth & development , Stainless Steel , Food Handling/instrumentation , Food Handling/methods , Food Contamination/analysis , Colony Count, Microbial
18.
BMC Musculoskelet Disord ; 25(1): 384, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755628

ABSTRACT

BACKGROUND: Customized 3D-printed pelvic implants with a porous structure have revolutionized periacetabular pelvic defect reconstruction after tumor resection, offering improved osteointegration, long-term stability, and anatomical fit. However, the lack of an established classification system hampers implementation and progress. METHODS: We formulated a novel classification system based on pelvic defect morphology and 3D-printed hemipelvis endoprostheses. It integrates surgical approach, osteotomy guide plate and prosthesis design, postoperative rehabilitation plans, and perioperative processes. RESULTS: Retrospectively analyzing 60 patients (31 males, 29 females), we classified them into Type A (15 patients: Aa = 6, Ab = 9), Type B (27 patients: Ba = 15, Bb = 12), Type C (17 patients). All underwent customized osteotomy guide plate-assisted tumor resection and 3D-printed hemipelvic endoprosthesis reconstruction. Follow-up duration was median 36.5 ± 15.0 months (range, 6 to 74 months). The mean operating time was 430.0 ± 106.7 min, intraoperative blood loss 2018.3 ± 1305.6 ml, transfusion volume 2510.0 ± 1778.1 ml. Complications occurred in 13 patients (21.7%), including poor wound healing (10.0%), deep prosthesis infection (6.7%), hip dislocation (3.3%), screw fracture (1.7%), and interface loosening (1.7%). VAS score improved from 5.5 ± 1.4 to 1.7 ± 1.3, MSTS-93 score from 14.8 ± 2.5 to 23.0 ± 5.6. Implant osseointegration success rate was 98.5% (128/130), with one Type Ba patient experiencing distal prosthesis loosening. CONCLUSION: The West China classification may supplement the Enneking and Dunham classification, enhancing interdisciplinary communication and surgical outcomes. However, further validation and wider adoption are required to confirm clinical effectiveness.


Subject(s)
Acetabulum , Bone Neoplasms , Printing, Three-Dimensional , Prosthesis Design , Humans , Female , Male , Retrospective Studies , Adult , Middle Aged , Acetabulum/surgery , Acetabulum/diagnostic imaging , Bone Neoplasms/surgery , Bone Neoplasms/diagnostic imaging , Young Adult , Osteotomy/methods , Plastic Surgery Procedures/methods , Plastic Surgery Procedures/instrumentation , Adolescent , Aged , Treatment Outcome , Postoperative Complications/etiology , Follow-Up Studies , Pelvic Bones/surgery , Pelvic Bones/diagnostic imaging
19.
BMC Musculoskelet Disord ; 25(1): 129, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38347518

ABSTRACT

OBJECTIVE: To study the biomechanical characteristics of each tissue structure when using different 3D printing Cage in osteoporotic patients undergoing interbody fusion. METHODS: A finite element model of the lumbar spine was reconstructed and validated with regarding a range of motion and intervertebral disc pressure from previous in vitro studies. Cage and pedicle screws were implanted and part of the lamina, spinous process, and facet joints were removed in the L4/5 segment of the validated mode to simulate interbody fusion. A 280 N follower load and 7.5 N·m moment were applied to different postoperative models and intact osteoporotic model to simulate lumbar motion. The biomechanical characteristics of different models were evaluated by calculating and analyzing the range of motion of the fixed and cephalic adjacent segment, the stress of the screw-rod system, the stress at the interface between cage and L5 endplate, and intervertebral disc pressure of the adjacent segment. RESULTS: After rigid fixation, the range of motion of the fixed segment of model A-C decreased significantly, which was much smaller than that of the osteoporotic model. And with the increase of the axial area of the interbody fusion cages, the fixed segment of model A-C tended to be more stable. The range of motion and intradiscal pressure of the spinal models with different interbody fusion cages were higher than those of the complete osteoporosis model, but there was no significant difference between the postoperative models. On the other hand, the L5 upper endplate stress and screw-rod system stress of model A-C show a decreasing trend in different directions of motion. The stress of the endplate is the highest during flexion, which can reach 40.5 MPa (model A). The difference in endplate stress between models A-C was the largest during lateral bending. The endplate stress of models A and B was 150.5% and 140.9% of that of model C, respectively. The stress of the screw-rod system was the highest during lateral bending (model A, 102.0 MPa), which was 108.4%, 102.4%, 110.4%, 114.2% of model B and 158.5%, 110.1%, 115.8%, 125.4% of model C in flexion, extension, lateral bending, and rotation, respectively. CONCLUSIONS: For people with osteoporosis, no matter what type of cage is used, good immediate stability can be achieved after surgery. Larger cage sizes provide better fixation without significantly increasing ROM and IDP in adjacent segments, which may contribute to the development of ASD. In addition, larger cage sizes can disperse endplate stress and reduce stress concentration, which is of positive significance in preventing cage subsidence after operation. The cage and screw rod system establish a stress conduction pathway on the spine, and a larger cage greatly enhances the stress-bearing capacity of the front column, which can better distribute the stress of the posterior spine structure and the stress borne by the posterior screw rod system, reduce the stress concentration phenomenon of the nail rod system, and avoid exceeding the yield strength of the material, resulting in the risk of future instrument failure.


Subject(s)
Osteoporosis , Pedicle Screws , Spinal Fusion , Humans , Finite Element Analysis , Spinal Fusion/methods , Biomechanical Phenomena , Range of Motion, Articular , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Osteoporosis/surgery
20.
BMC Musculoskelet Disord ; 25(1): 127, 2024 Feb 10.
Article in English | MEDLINE | ID: mdl-38341564

ABSTRACT

OBJECTIVES: To Investigate the value of 3D printed guide-assisted percutaneous management of minimally displaced scaphoid waist fractures(Herbert's B2) with delayed diagnosis or presentation. METHODS: From October 2018 to February 2022, 10 patients with established delayed diagnoses and presentation of minimally displaced scaphoid waist fractures were treated with 3D printed guides assisted with percutaneous internal fixation without bone grafting. This technique was based on the patient's preoperative CT and imported into the software. Based on Boolean subtraction, the most centralized screw placement position was identified and a customized guide was produced. Intraoperative percutaneous insertion of the guide wire was assisted by the custom guide. RESULTS: All 10 patients were successful in one attempt. The fractures healed at a mean of 7.7 weeks postoperatively (range 6-10 weeks). At a mean follow-up of 7.7 months (6-13 months), patients had excellent recovery of wrist function with minimal pain reduction. There were no major postoperative complications and the patients all returned to their previous activities before the injury. CONCLUSIONS: Percutaneous internal fixation based on 3D printed guides is a safe and effective technique for delayed diagnosis or presentation of patients with minimally displaced fractures of the scaphoid waist. This method allows for easy insertion of screws and avoids multiple attempts.


Subject(s)
Fractures, Bone , Hand Injuries , Scaphoid Bone , Wrist Injuries , Humans , Delayed Diagnosis , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Fracture Fixation, Internal/methods , Wrist Injuries/surgery , Bone Screws , Scaphoid Bone/diagnostic imaging , Scaphoid Bone/surgery , Scaphoid Bone/injuries , Printing, Three-Dimensional
SELECTION OF CITATIONS
SEARCH DETAIL