Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 436
Filter
Add more filters

Publication year range
1.
J Cardiovasc Electrophysiol ; 35(6): 1078-1082, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38509774

ABSTRACT

INTRODUCTION: Percutaneous left atrial appendage occlusion (LAAO) is traditionally performed under general anesthesia with trans-esophageal echocardiography guidance. Intracardiac echo (ICE)-guided LAAO closure is increasing in clinical use. The ICE catheter is crossed into LA via interatrial septum (IAS) after the septum is dilated with LAAO delivery sheath. This step can be time-consuming and requires significant ICE catheter manipulation, which increases the risk of cardiac perforation. Pre-emptive septal balloon dilation can potentially help with ICE advancement in the LA. We sought to evaluate the effect of pre-dilation of the IAS with an 8 mm balloon on the ease of crossing the ICE catheter, fluoroscopy time for crossing, and overall procedure time. METHODS: The Piedmont LAAO registry was used to identify consecutive patients who underwent LAAO. The initial 25 patients in whom balloon dilation of the IAS was performed served as the experimental cohort, and the 25 consecutive patients before that in whom balloon dilation was not performed served as controls. In the experimental group, after a trans-septal puncture, the sheath was retracted to the right atrium with a guidewire still in the LA. An 8 × 40 mm Evercoss™ over the wire balloon was inflated across the IAS. The ICE catheter was then crossed into the LA using the fluoroscopic landmark of the guide wire and the ICE imaging. The sheath was then advanced along the ICE catheter via the transseptal puncture (TSP) and the procedure continued. Follow-up compputed tomography imaging was obtained at 4-8 weeks. RESULTS: Each group consisted of 25 patients. There were no significant differences in baseline characteristics. All procedures were performed successfully under conscious sedation and ICE guidance. There was a significant reduction in the overall procedure time, fluoroscopy time, and time for transseptal puncture to ICE in LA. There was no difference in the size of the acute residual interatrial shunt, as measured via ICE, or the size and presence of iatrogenic ASD at follow-up. CONCLUSION: Balloon dilation of TSP is safe and is associated with increased efficiency in ICE-guided LAAO procedures.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Catheterization , Registries , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Male , Female , Aged , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Treatment Outcome , Atrial Fibrillation/therapy , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Ultrasonography, Interventional , Time Factors , Aged, 80 and over , Middle Aged , Atrial Septum/diagnostic imaging , Predictive Value of Tests
2.
J Cardiovasc Electrophysiol ; 35(1): 44-57, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37927196

ABSTRACT

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used during left atrial appendage occlusion (LAAO) as an alternative to transesophageal echocardiography (TEE). The objective of this study is to evaluate the impact of ICE versus TEE guidance during LAAO on procedural characteristics and acute outcomes, as well the presence of peri-device leaks and residual septal defects during follow-up. METHODS: All studies comparing ICE-guided versus TEE-guided LAAO were identified. The primary outcomes were procedural efficacy and occurrence of procedure-related complications. Secondary outcomes included lab efficiency (defined as a reduction in in-room time), procedural time, fluoroscopy time, and presence of peri-device leaks and residual interatrial septal defects (IASD) during follow-up. RESULTS: Twelve studies (n = 5637) were included. There were no differences in procedural success (98.3% vs. 97.8%; OR 0.73, 95% CI 0.42-1.27, p = .27; I2 = 0%) or adverse events (4.5% vs. 4.4%; OR 0.81 95% CI 0.56-1.16, p = .25; I2 = 0%) between the ICE-guided and TEE-guided groups. ICE guidance reduced in in-room time (mean-weighted 28.6-min reduction in in-room time) without differences in procedural time or fluoroscopy time. There were no differences in peri-device leak (OR 0.93, 95% CI 0.68-1.27, p = 0.64); however, an increased prevalence of residual IASD was observed with ICE-guided versus TEE-guided LAAO (46.3% vs. 34.2%; OR 2.23, 95% CI 1.05-4.75, p = 0.04). CONCLUSION: ICE guidance is associated with similar procedural efficacy and safety, but could result in improved lab efficiency (as established by a significant reduction in in-room time). No differences in the rate of periprocedural leaks were found. A higher prevalence of residual interatrial septal defects was observed with ICE guidance.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Echocardiography, Transesophageal , Treatment Outcome
3.
Article in English | MEDLINE | ID: mdl-38984646

ABSTRACT

A patient presenting with acute ischemic stroke associated with patent foramen ovale (PFO) had concurrent deep vein thrombosis, pulmonary embolism, and new-onset atrial fibrillation. Upon initiation of anticoagulation therapy, the patient developed hemorrhagic transformation of the stroke. The patient's multiple potential sources of embolic stroke were treated with concomitant left atrial appendage occlusion and PFO closure through the PFO, made possible by using the Steerable Amulet Sheath under 3D-intracardiac echocardiography guidance.

4.
Catheter Cardiovasc Interv ; 103(1): 129-136, 2024 01.
Article in English | MEDLINE | ID: mdl-37786977

ABSTRACT

BACKGROUND: While studies have shown the advantages of computed tomography angiography (CTA) over transesophageal echocardiography (TEE) in left atrial appendage closure (LAAC) preprocedural planning for WATCHMAN™ legacy and FLX devices, there has been no reported long-term data for this approach. OBJECTIVES: We sought to evaluate long-term outcomes using CTA-based preprocedural planning for LAAC using the WATCHMAN™ device. METHODS: A prospective analysis of 231 consecutive patients who underwent LAAC in a single, large academic hospital in the United States was conducted over a 5-year period. CTA-guided preprocedural planning was performed in all. Procedural success, adverse events, length of procedure, number of devices used, and length of stay were evaluated. Rates of death, cerebral embolism, systemic embolism, and major and minor bleeding were recorded. Adjusted predicted stroke and major bleeding rates were derived from CHA2DS2-Vasc and HAS-BLED scores, respectively. RESULTS: From January 26, 2017, to November 23, 2021, 231 patients underwent LAAC with CTA preprocedural planning by two operating physicians. The mean age of patients was 76.5 ± 8.4. 59.7% of patients were male. Mean CHA2DS2VASc and HAS-BLED scores were 4.5 ± 1.4 and 3.9 ± 0.9, respectively. All procedures were performed with intracardiac echo (100%). The procedural success rate was 99.1%. The CTA sizing strategy accurately predicted the implant size in 93.5% of patients. Mean number of devices used was 1.10 ± 0.3. Peri-procedural complication rate was 2.2%. 6 patients were lost to follow-up. Mean follow-up was 608.94 days with a total of 377.04 patient years. Median follow-up period of 368 days (interquartile range: 209-1067 days). There were 51 deaths from all causes (13.52 per 100 patient-years), 10 cases of cerebral embolism (2.65 per 100 patient-years), 2 cases of systemic embolism (0.53 per 100 patient-years), 17 cases of major bleeding (4.50 per 100 patient-years), and 31 cases of minor bleeding (8.2 per 100 patient-years). All-cause mortality at 1, 2, and 3 years was 12.7%, 20.9%, and 29.2%, respectively. CV event rates at 1, 2, and 3 years were 2.1%, 6.6%, and 10.5%, respectively. CONCLUSIONS: CTA-based preprocedural planning is accurate in predicting device size for LAAC and associated with excellent clinical outcomes at 5 years.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Embolism , Intracranial Embolism , Stroke , Humans , Male , Female , Follow-Up Studies , Left Atrial Appendage Closure , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/therapy , Atrial Fibrillation/complications , Computed Tomography Angiography , Treatment Outcome , Intracranial Embolism/diagnostic imaging , Intracranial Embolism/etiology , Intracranial Embolism/prevention & control , Atrial Appendage/diagnostic imaging , Stroke/etiology , Hemorrhage , Echocardiography, Transesophageal/adverse effects
5.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38366154

ABSTRACT

AIMS: Common to adult electrophysiology studies (EPSs), intracardiac echocardiography (ICE) use in paediatric and congenital heart disease (CHD) EPS is limited. The purpose of this study was to assess the efficacy of ICE use and incidence of associated complications in paediatric and CHD EPS. METHODS AND RESULTS: This single-centre retrospective matched cohort study reviewed EPS between 2013 and 2022. Demographics, CHD type, and EPS data were collected. Intracardiac echocardiography cases were matched 1:1 to no ICE controls to assess differences in complications, ablation success, fluoroscopy exposure, procedure duration, and arrhythmia recurrence. Cases and controls with preceding EPS within 5 years were excluded. Intracardiac echocardiography cases without an appropriate match were excluded from comparative analyses but included in the descriptive cohort. We performed univariable and multivariable logistic regression to assess associations between variables and outcomes. A total of 335 EPS were reviewed, with ICE used in 196. The median age of ICE cases was 15 [interquartile range (IQR) 12-17; range 3-47] years, and median weight 57 [IQR 45-71; range 15-134] kg. There were no ICE-related acute or post-procedural complications. There were 139 ICE cases matched to no ICE controls. Baseline demographics and anthropometrics were similar between cases and controls. Fluoroscopy exposure (P = 0.02), procedure duration (P = 0.01), and arrhythmia recurrence (P = 0.01) were significantly lower in ICE cases. CONCLUSION: Intracardiac echocardiography in paediatric and CHD ablations is safe and reduces procedure duration, fluoroscopy exposure, and arrhythmia recurrence. However, not every arrhythmia substrate requires ICE use. Thoughtful selection will ensure the judicious and strategic application of ICE to enhance outcomes.


Subject(s)
Catheter Ablation , Heart Defects, Congenital , Adult , Humans , Child , Retrospective Studies , Cohort Studies , Treatment Outcome , Arrhythmias, Cardiac/diagnostic imaging , Arrhythmias, Cardiac/surgery , Echocardiography/methods , Fluoroscopy , Catheter Ablation/adverse effects , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery
6.
Pacing Clin Electrophysiol ; 47(4): 554-557, 2024 04.
Article in English | MEDLINE | ID: mdl-37377404

ABSTRACT

The strategy after battery depletion was not established in Micra leadless pacemaker system (Micra). There are still some concerns in the 2nd Micra implantation, such as the mechanical interaction between both devices. The position of the 2nd Micra should be placed apart from the 1st Micra. We present a case of 1st Micra battery depletion who successfully underwent the 2nd Micra implantation under the intracardiac echo guidance. In our case, intracardiac echo was a very effective tool for confirming the location of Micra implantation.


Subject(s)
Pacemaker, Artificial , Humans , Treatment Outcome , Equipment Design , Heart , Echocardiography
7.
Pacing Clin Electrophysiol ; 47(1): 117-120, 2024 01.
Article in English | MEDLINE | ID: mdl-37885274

ABSTRACT

Pulse field ablation (PFA) is a novel nonthermal ablation modality for treatment of atrial fibrillation. While mostly lacking 3D electroanatomical mapping integration, reported radiation doses in procedures using multielectrode PFA catheters are relatively high. We report a first case series of three patients where a zero-fluoroscopy approach by intracardiac echocardiography was utilized and present a possible workflow for zero-fluoroscopy ablation with the Farapulse PFA system.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Irreversible Electroporation Therapy , Treatment Outcome , Catheter Ablation/methods , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Fluoroscopy/methods
8.
Article in English | MEDLINE | ID: mdl-38501848

ABSTRACT

Ventricular diverticula are saccule-like structures formed by the protrusion of the ventricular myocardium from the endocardial surface towards the free wall. Most diverticula are muscular structures, and patients usually have no obvious clinical symptoms. However, diverticula may contribute to arrhythmogenesis due to localized myocardial structural disturbances. Right ventricular apical diverticulum (RVAD) is very rare, and we report a case of highly symptomatic accelerated idioventricular rhythm (AIVR) originating from the RVAD that underwent intracardiac echocardiography (ICE)-guided catheter ablation with no recurrence during follow-up.

9.
Pacing Clin Electrophysiol ; 47(3): 448-454, 2024 03.
Article in English | MEDLINE | ID: mdl-38291877

ABSTRACT

BACKGROUND: Application of electrocautery to a J-wire is used to perform transseptal puncture (TSP), but with limited evidence supporting safety and efficacy. We conducted a prospective randomized controlled trial to evaluate the safety and efficacy of this technique. METHODS: Two hundred consecutive patients were randomized in a 1:1 fashion to either the ICE-guided electrified J-wire TSP group or a conventional Brockenbrough (BRK) needle TSP group. The TSP was performed with a 0.032″ guidewire under 20 W, "coag" mode and was compared to TSP using the BRK needle. The primary safety endpoints were complications related to TSP. The primary efficacy endpoints included the TSP success rate, the total TSP time, and the total procedure time. RESULTS: All patients complete the procedure safely. The electrified J-wire TSP group had a significantly shorter TSP time than BRK needle TSP group. The total procedure time, number of TSP attempts required to achieve successful LA access, width of the intra-atrial shunt at the end of ablation were similar between the two groups. The incidence of new cerebral infarction detected by MRI were similar between the two groups (3/32 patients in the J-wire TSP group and 2/26 patients in conventional BRK TSP group, p = .82). And no difference in the incidence of residual intra-atrial shunt (4.3% vs. 6%, p = .654) during the 3-month's follow up. CONCLUSION: Using an electrified J-wire for TSP under the guidance of ICE appears to be as safe as and more efficient than conventional BRK needle TSP, which may be especially useful in the era of non-fluoroscopy AF ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Heart Septum/diagnostic imaging , Heart Septum/surgery , Atrial Fibrillation/surgery , Prospective Studies , Punctures/methods , Catheter Ablation/methods , Echocardiography , Treatment Outcome
10.
Echocardiography ; 41(1): e15724, 2024 01.
Article in English | MEDLINE | ID: mdl-38064288

ABSTRACT

BACKGROUND AND AIM: Our aim was to evaluate the fluoroscopy time (FT), procedure time (PT) safety and efficacy when using intracardiac echocardiography (ICE) in comparison to transesophageal echocardiography (TEE) guidance for transcatheter closure of Ostium Secundum Atrial Septal Defect (OS-ASD). METHOD: Ninety patients (n = 90) diagnosed with OS-ASD underwent transcatheter closure between March 2006 and October 2021. Fifty-seven patients were treated under ICE guidance, while 33 patients were treated under TEE guidance. RESULTS: Mean age was 43 ± 15 years and 42 ± 10 years in the ICE and TEE groups, respectively. The majority of patients had a centrally placed defect. Median FT was 8.40 min versus 11.70 min (p < .001) in the ICE group compared to the TEE group, respectively. Median PT was 43 min versus 94 min (p < .001) in the ICE group compared to the TEE group, respectively. Both ICE and TEE provided high quality images. All interventions were completed successfully, except for one patient in the ICE group who experienced a device migration, the development of atrial tachycardia in one patient and atrial fibrillation in two patients in the ICE group which spontaneously cardioverted. There were no other complications. CONCLUSION: This study on a consistent cohort of patients with OS-ASD undergoing percutaneous closure suggests that use of ICE is safe and efficacious. Compared to TEE, ICE demonstrated significantly shorter FT and PT, decreasing the entire duration of the procedure and x-ray exposure. No relevant differences were observed in terms of success rate and complications.


Subject(s)
Atrial Fibrillation , Heart Septal Defects, Atrial , Humans , Adult , Middle Aged , Echocardiography, Transesophageal/methods , Cardiac Catheterization/methods , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Fluoroscopy , Treatment Outcome
11.
Curr Cardiol Rep ; 2024 Jul 12.
Article in English | MEDLINE | ID: mdl-38995505

ABSTRACT

PURPOSE OF THE REVIEW: Intracardiac echocardiography (ICE) provides real-time, fluoroless imaging of cardiac structures, allowing optimal catheter positioning and energy delivery during ablation procedures. This review summarizes the use of ICE in catheter ablation of atrial fibrillation (AF). RECENT FINDINGS: Growing evidence suggests that the use of ICE improves procedural safety and facilitates radiofrequency and cryoballoon AF ablation. ICE-guided catheter ablation is associated with reduced procedural duration and fluoroscopy use. Recent studies have examined the role of ICE in guiding novel ablation techniques, such as pulsed field ablation. Finally, the use of ICE allows for early detection and timely management of potentially serious procedural complications. Intracardiac echocardiography offers significant advantages during AF ablation procedures and its use should be encouraged to improve procedural safety and efficacy.

12.
Pediatr Cardiol ; 45(1): 213-215, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37930376

ABSTRACT

Three-dimensional intracardiac echocardiography (3D ICE) has gained popularity in interventional cardiology given its improved spatial and temporal imaging in assessing intracardiac anatomy pre- and post-intervention. We describe the use of 3D ICE in the reduction of a Fontan fenestration with an Occlutech atrial flow regulator (AFR) device.


Subject(s)
Echocardiography, Three-Dimensional , Heart Atria , Humans , Heart Atria/diagnostic imaging , Heart Atria/surgery , Echocardiography, Three-Dimensional/methods , Cardiac Catheterization
13.
J Cardiovasc Electrophysiol ; 34(3): 638-649, 2023 03.
Article in English | MEDLINE | ID: mdl-36640432

ABSTRACT

INTRODUCTION: Endocardial pace mapping (PM) can identify conducting channels for ventricular tachycardia (VT) circuits in patients with structural heart disease (SHD). Recent findings show the temporal and spatial pattern of PM may aid identification of the surface harboring VT isthmii. The specific correlation of PM patterns to scar topography has not been examined. OBJECTIVE: To correlate the pattern of endocardial PMs to underlying scar topography in SHD patients with VT. METHODS: Data from patients undergoing VT ablation from August 2018 to February 2022 were reviewed. RESULTS: Sixty-three patients with SHD-related VT (mean age 65 ± 14 years) with 83 endocardial PM correlation maps were analysed. Two main correlation patterns were identified, an "abrupt-change correlation pattern (AC-pattern)" and "centrifugal-attenuation correlation pattern (CA-pattern)." AC-pattern had lower scar ratio (unipolar/bipolar % scar area; 1.1 vs. 1.5, p < .001), had longer maximal stimulus-QRS intervals (97.5 vs. 68 ms, p = .002), and higher likelihood of endocardial dominant scar (11/21 [52%] vs. 3/38 [8%], p < .001) than CA-pattern seen on intracardiac echocardiography (ICE). In contrast, CA-pattern was more likely to have epicardial dominant scar or mid-intramural scar on ICE (epicardial dominant scar; CA-pattern: 12/38 [32%] vs. AC-pattern: 1/21 [5%], p = .02, mid-intramural scar; CA-pattern: 15/38 [39%] vs. AC-pattern: 1/21 [5%], p = .005). CONCLUSIONS: The spatial pattern of endocardial PM in SHD-related VT directly correlates with scar topography. AC-pattern is associated with endocardial dominant scar on ICE with lower scar ratio and longer stimulus-QRS intervals, whereas CA-pattern is strongly associated with epicardial dominant or mid-intramural scar with higher scar ratio and shorter stimulus-QRS intervals.


Subject(s)
Catheter Ablation , Heart Diseases , Tachycardia, Ventricular , Humans , Middle Aged , Aged , Cicatrix , Pericardium , Endocardium
14.
J Cardiovasc Electrophysiol ; 34(10): 2029-2039, 2023 10.
Article in English | MEDLINE | ID: mdl-37681996

ABSTRACT

INTRODUCTION: Cryoballoon ablation (CBA) aiming at pulmonary vein isolation (PVI) became a standardized atrial fibrillation (AF) ablation procedure. Life-threatening complications like cardiac tamponade exist. Intracardiac echocardiography (ICE) usage is associated with superior safety in radiofrequency ablation. It is unclear if ICE has an impact on safety of CBA. METHODS: The FREEZE Cohort (NCT01360008) subanalysis included patients undergoing "PVI only" CBA. Patients with intraprocedural transesophageal echocardiography were excluded. Group A comprises conventional, group B ICE-guided CBA. Periprocedural results were compared. RESULTS: From 2011 to 2016, a total of 4189 patients were enrolled, and 1906 (45.5%) were included in this subanalysis, split up in two groups (A: 1066 [55.9%], B: 840 [44.1%]). Group A was younger (60.6 ± 10.8 vs. 62.4 ± 10.5 years, p < .001), with smaller left atria (41 vs. 43 mm, p < .001), and less persistent AF (23.1 vs. 38.1%, p < .001). Procedure, left atrial, and fluoroscopy times were shorter in group A as compared to group B. Dose area product was significantly higher in group A (2911 vs. 2072 cGyxcm2 , p < .001). In-hospital major adverse cerebrovascular and cardiac event rates including two deaths in group A were not different between groups (0.5% vs. 0.1%, p = .18). The rate of total procedural (10.4% vs. 5.1%, p < .001) and major complications (3.2% vs. 1.3%, p < .001) was significantly higher in group A. Cardiac tamponade occurred significantly more frequently in group A (8 [0.8%] vs. 1 [0.1%], p = .046). Independent predictors for major complications were female sex (odds ratio [OR] 2.03, p = .03) and non-ICE usage (OR 2.38, p = .02). No differences were observed for persistent phrenic nerve palsy, nor for groin complications. CONCLUSION: CBA was significantly safer and required less radiation if ICE was used, although the procedures were more complex. The risk of groin complications was not increased with ICE usage. Non-ICE usage was the only modifiable independent predictor of major complications.


Subject(s)
Atrial Fibrillation , Cardiac Tamponade , Catheter Ablation , Cryosurgery , Pulmonary Veins , Female , Humans , Male , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Cardiac Tamponade/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cohort Studies , Cryosurgery/adverse effects , Cryosurgery/methods , Echocardiography , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Recurrence , Treatment Outcome , Prospective Studies
15.
J Cardiovasc Electrophysiol ; 34(3): 673-681, 2023 03.
Article in English | MEDLINE | ID: mdl-36651353

ABSTRACT

INTRODUCTION: The anatomical substrate for idiopathic left ventricular tachycardia (ILVT) remains speculative. Purkinje networks surrounding false tendons (FTs) might be involved in the reentrant circuit of ILVT. The objective was to evaluate the anatomical and electrophysiological features of false tendons FTs in relation to ILVT. METHODS: Intracardiac echocardiography (ICE) was conducted on patients with ILVT. The relationship of the FTs with ILVT was determined using electro-anatomical mapping. RESULTS: Electrophysiological evaluation and radiofrequency ablation were conducted in 23 consecutive patients with ILVT. FTs were identified in 19/23 cases (82.6%) with P1 potentials during VT recorded at the FT in 14 of these patients (73.7%). Three FT types were identified. In type 1, the FT attached the septum to the base of the posteromedial papillary muscle (PPM) (4/19); type 2 FTs ran between the septum and the PPM apex (3/19), while in type 3, the connection occurred between the septum and apex (11/19) or between the septum and the LV free wall (1/19). The effective ILVT ablation sites were situated at the FT-PPM (3/19) and the FT-septum (16/19) attachment sites. CONCLUSIONS: This series demonstrates the association between Purkinje fibers and FTs during catheter ablation of ILVT and verifies that left ventricular FTs are an important substrate in this type of tachycardia.


Subject(s)
Catheter Ablation , Heart Defects, Congenital , Tachycardia, Ventricular , Humans , Electrocardiography , Purkinje Fibers , Heart Ventricles
16.
Catheter Cardiovasc Interv ; 102(1): 155-158, 2023 07.
Article in English | MEDLINE | ID: mdl-37210620

ABSTRACT

A 70-year-old man with history of transcatheter aortic valve-in-valve implantation was admitted because of suspected infective endocarditis (IE). Transesophageal echocardiogram did not reveal any vegetations, as the metallic stent frames caused significant artifacts. Position emission tomography was also negative. Intracardiac echocardiogram (ICE) was performed retrogradely through the ascending aorta, which showed clear vegetations over the stent frame of the transcatheter heart valve. Endocarditis after transcatheter aortic valve implantation was not uncommon. With increasing use of valve-in-valve procedures, echocardiographic diagnosis of IE would be more challenging. This case demonstrated the advantage of ICE over conventional echocardiography in visualizing the neo-aortic valve complex for diagnosing IE.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Prosthesis-Related Infections , Transcatheter Aortic Valve Replacement , Male , Humans , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Prosthesis-Related Infections/diagnostic imaging , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/therapy , Treatment Outcome , Endocarditis, Bacterial/diagnostic imaging , Endocarditis, Bacterial/etiology , Endocarditis, Bacterial/surgery , Endocarditis/etiology , Endocarditis/complications , Transcatheter Aortic Valve Replacement/adverse effects , Echocardiography/adverse effects
17.
Europace ; 25(4): 1352-1360, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36857524

ABSTRACT

OBJECTIVE: This study aimed to evaluate the feasibility of real-time visualization and mapping of the right phrenic nerve (RPN) by using intracardiac echocardiography (ICE) during atrial fibrillation (AF) ablation. BACKGROUND: RPN injury is a complication associated with the ablation of AF. Multiple approaches are currently being used to prevent and detect RPN injuries. However, none of these approaches can directly visualize the RPN in real-time during the ablation procedure. METHODS AND RESULTS: The RPN was detected using ICE. The RPN and its adjacent structures were analysed. The relationship between the RPN's distance from the superior vena cava (SVC) and its pacing capture threshold was quantified. The safety of SVC isolation guided by the ICE-visualized RPN was evaluated. Thirty-eight people were enrolled in this study. The RPN was visualized by ICE in 92% of patients. It ran through the space between the SVC and the mediastinal pleura and had a 'straw'-like appearance upon ICE imaging. The course of the RPN was close to the SVC (minimum 1.0 ± 0.4 mm) and the right superior pulmonary vein (minimum 14.1 ± 7.3 mm). There was a positive linear correlation between the RPN's capture threshold and its distance from the SVC (Spearman's correlation coefficient = 0.728, < 0.001). SVC isolation was guided by the RPN; none of the patients developed an RPN injury. CONCLUSIONS: RPN can be visualized by ICE in most patients, thus providing a novel approach for the real-time detection of RPN during AF ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Phrenic Nerve/injuries , Vena Cava, Superior/diagnostic imaging , Vena Cava, Superior/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Echocardiography , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery
18.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37021403

ABSTRACT

AIMS: The development of intracardiac echocardiography (ICE) has enabled fluoroless atrial fibrillation (AF) ablation using three-dimensional electroanatomical mapping systems. However, fluoroless cryoballoon ablation (CBA) remains challenging, mainly because of the lack of a visual mapping system. Hence, this study aimed to investigate the safety and efficacy of fluoroless CBA for AF under ICE guidance. METHODS AND RESULTS: Patients (n = 100) who underwent CBA for paroxysmal AF were randomly assigned to zero-fluoroscopic (Zero-X) and conventional groups. Intracardiac echocardiography was used to guide the transseptal puncture and catheter and balloon manipulation in all enrolled patients. The patients were prospectively followed for 12 months after CBA. The mean age was 60.4 years, and the left atrial (LA) size was 39.4 mm. Pulmonary vein isolation (PVI) was achieved in all patients. In the Zero-X group, fluoroscopy was used in only one patient because of unstable phrenic nerve capture during right-sided PVI. The procedure time and LA indwelling time in the Zero-X group were not statistically different compared with that in the conventional group. Fluoroscopic time (9.0 vs. 0.008 min) and radiation exposure (29.4 vs. 0.02 mGy) were significantly shorter in the Zero-X group than in the conventional group (P < 0.001). The complication rate did not differ between the two groups. During a mean follow-up of 663.3 ± 172.3 days, the recurrence rate was similar (16.0 vs. 18.0%; P = 0.841) between the groups. Multivariate analysis revealed that LA size was the only independent predictor of clinical recurrence. CONCLUSION: Intracardiac echocardiography-guided fluoroless CBA for AF was a feasible strategy without compromising acute and long-term success or complication rates.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Middle Aged , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Prospective Studies , Treatment Outcome , Fluoroscopy , Echocardiography , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Cryosurgery/adverse effects , Cryosurgery/methods
19.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37477946

ABSTRACT

AIMS: Intracardiac echocardiography (ICE) is a useful but operator-dependent tool for left atrial (LA) anatomical rendering during atrial fibrillation (AF) ablation. The CARTOSOUND FAM Module, a new deep learning (DL) imaging algorithm, has the potential to overcome this limitation. This study aims to evaluate feasibility of the algorithm compared to cardiac computed tomography (CT) in patients undergoing AF ablation. METHODS AND RESULTS: In 28 patients undergoing AF ablation, baseline patient information was recorded, and three-dimensional (3D) shells of LA body and anatomical structures [LA appendage/left superior pulmonary vein/left inferior pulmonary vein/right superior pulmonary vein/right inferior pulmonary vein (RIPV)] were reconstructed using the DL algorithm. The selected ultrasound frames were gated to end-expiration and max LA volume. Ostial diameters of these structures and carina-to-carina distance between left and right pulmonary veins were measured and compared with CT measurements. Anatomical accuracy of the DL algorithm was evaluated by three independent electrophysiologists using a three-anchor scale for LA anatomical structures and a five-anchor scale for LA body. Ablation-related characteristics were summarized. The algorithm generated 3D reconstruction of LA anatomies, and two-dimensional contours overlaid on ultrasound input frames. Average calculation time for LA reconstruction was 65 s. Mean ostial diameters and carina-to-carina distance were all comparable to CT without statistical significance. Ostial diameters and carina-to-carina distance also showed moderate to high correlation (r = 0.52-0.75) except for RIPV (r = 0.20). Qualitative ratings showed good agreement without between-rater differences. Average procedure time was 143.7 ± 43.7 min, with average radiofrequency time 31.6 ± 10.2 min. All patients achieved ablation success, and no immediate complications were observed. CONCLUSION: DL algorithm integration with ICE demonstrated considerable accuracy compared to CT and qualitative physician assessment. The feasibility of ICE with this algorithm can potentially further streamline AF ablation workflow.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Artificial Intelligence , Feasibility Studies , Echocardiography/methods , Heart Atria/diagnostic imaging , Heart Atria/surgery , Imaging, Three-Dimensional/methods , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Algorithms , Catheter Ablation/methods
20.
Europace ; 26(1)2023 Dec 28.
Article in English | MEDLINE | ID: mdl-38225176

ABSTRACT

AIMS: Left atrial appendage (LAA) imaging is critical during percutaneous occlusion procedures. 3D-intracardiac echocardiography (ICE) features direct visualization of LAA from multiple cross-sectional planes at a time. We aimed at reporting procedural success of 3D-ICE-guided LAA occlusion and the correlation between pre-procedural transoesophageal echocardiography (TEE) and intraprocedural 3D-ICE for LAA sizing. METHODS AND RESULTS: Among 274 patients undergoing left atrial appendage occlusion (LAAO) with a Watchman FLX, periprocedural ICE guidance was achieved via a commercially available 2D-ICE catheter (220 patients) or a novel (NUVISION™) 3D-ICE one (54 patients). Primary endpoint was a composite of procedural success and LAA sealing at follow-up TEE. Secondary endpoint was a composite of periprocedural device recapture/resizing plus presence of leaks ≥ 3 mm at follow-up TEE. 3D-ICE measurements of maximum landing zone correlated highly with pre-procedural TEE reference values [Pearson's: 0.94; P < 0.001; bias: -0.06 (-2.39, 2.27)]. The agreement between 3D-ICE-based device selection and final device size was 96.3% vs. 79.1% with 2D-ICE (P = 0.005). The incidence of the primary endpoint was 98.1% with 3D-ICE and 97.3% with 2D-ICE (P = 0.99). 2D-ICE patients had a trend towards a higher incidence of periprocedural device recapture/redeployment (31.5% vs. 44.5%; P = 0.09). The secondary endpoint occurred in 31.5% of 3D-ICE patients vs. 45.9% of 2D-ICE ones (P = 0.065). CONCLUSION: Intracardiac echocardiography-guided LAAO showed a very high success, with no major adverse events. A very high level of agreement for LAA sizing was found between pre-procedural TEE and periprocedural 3D-ICE. 3D-ICE performed significantly better than 2D-ICE for FLX size selection and may provide better guidance during device deployment.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Cross-Sectional Studies , Treatment Outcome , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Cardiac Catheterization , Echocardiography, Transesophageal/methods , Echocardiography/methods
SELECTION OF CITATIONS
SEARCH DETAIL