Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 349
Filter
Add more filters

Publication year range
1.
Catheter Cardiovasc Interv ; 103(1): 147-152, 2024 01.
Article in English | MEDLINE | ID: mdl-37855205

ABSTRACT

BACKGROUNDS: Transcatheter edge-to-edge repair (TEER) devices are used for primary mitral regurgitation (MR) and secondary MR. Despite the growing use of TEER devices, there have not been many studies on operator experience or procedure volumes by state. AIMS: We aimed to investigate nationwide operator volume trends and geographic variation in access to TEER. METHODS: The United States Center for Medicare and Medicaid Services (CMS) National Medicare Provider Utilization and Payment Database (MPUPD) was analyzed between 2015 and 2020 for initial TEER procedures. RESULTS: Procedure volume and total operators increased yearly from 2015 to 2019 but declined in 2020. Mean annual procedure volume per operator varied significantly by state, between 0 in multiple states and 35 in North Dakota. In 2019, 994 unique operators were identified, with 295 operators documented performing 10 or more procedures (29.68%). Operators performing 10 or more TEER procedures provided 68.46% of all operations in 2019, averaging 20.94 procedures per operator. CONCLUSIONS: TEER procedures are becoming increasingly common as more operators are being trained. However, significant variability exists in the procedural volume per operator.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aged , United States , Humans , Medicare , Treatment Outcome , Databases, Factual , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery
2.
Catheter Cardiovasc Interv ; 104(2): 378-389, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38829174

ABSTRACT

BACKGROUND: Vasopressor test (VPT) might be useful in patients with functional mitral regurgitation (MR) and left ventricular dysfunction (MITRA-FR-like patients) during transcatheter edge-to-edge repair (TEER). AIMS: We aimed to evaluate the prognostic impact of VPT. METHODS: MR treated with TEER were included in a multicenter prospective registry. VPT was used intraprocedurally in patients with left ventricular dysfunction and/or hypotension. The 1-year echocardiographic and clinical outcomes were compared according to the use of VPT. The primary endpoint was a combination of mortality + heart failure (HF) readmission at 1-year. RESULTS: A total of 1115 patients were included, mean age was 72.8 ± 10.5 years and 30.4% were women. VPT was performed in 128 subjects (11.5%), more often in critically ill patients with biventricular dysfunction. Postprocedurally the VPT group had greater rate of MR ≥ 2+ (46.9% vs. 31.7%, p = 0.003) despite greater number of devices (≥2 clips, 52% vs. 40.6 p = 0.008) and device repositioning or new clip in 12.5%. At 1-year, the primary endpoint occurred more often in the VPT group (27.3% vs. 16.9%, p = 0.002) as well as all-cause mortality (21.9% vs. 8.1%, p ≤ 0.001) but no differences existed in HF readmission rate (14.8% vs. 13.2%, p = 0.610), cardiovascular mortality (4.4% vs. 3.9%, p = 0.713) or residual MR ≥ 2+ (51.1% vs 51.7%, p = 0.371). CONCLUSIONS: Dynamic evaluation of MR during TEER procedure through VPT was performed in patients with worse baseline risk who also presented higher all-cause mortality at 1-year follow-up. However, 1-year residual MR, cardiovascular mortality and HF readmission rate remained comparable suggesting that VPT might help in the management of MITRA-FR-like patients.


Subject(s)
Cardiac Catheterization , Mitral Valve Insufficiency , Mitral Valve , Patient Readmission , Predictive Value of Tests , Registries , Ventricular Function, Left , Humans , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/surgery , Female , Aged , Male , Treatment Outcome , Time Factors , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Prospective Studies , Aged, 80 and over , Risk Factors , Mitral Valve/physiopathology , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Middle Aged , Vasoconstrictor Agents/therapeutic use , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left/mortality , Ventricular Dysfunction, Left/diagnostic imaging , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Heart Failure/physiopathology , Heart Failure/mortality , Heart Failure/diagnosis , Recovery of Function , Risk Assessment , Hemodynamics
3.
Catheter Cardiovasc Interv ; 103(7): 1138-1144, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38695165

ABSTRACT

Following the introduction in the latest European and American guidelines, transcatheter edge-to-edge repair has become a valid alternative to surgery for ineligible patients. Among the available technologies, MitraClip (Abbott) was the first to be introduced for the percutaneous treatment of mitral regurgitation with the edge-to-edge technique. Although its safety and effectiveness has been widely demonstrated, the optimal procedural results are highly dependent from operators' experience. In this manuscript, we provide a full guide of advanced steering maneuvers of MitraClip in different scenarios of transseptal puncture.


Subject(s)
Cardiac Catheterization , Cardiac Catheters , Mitral Valve Insufficiency , Mitral Valve , Punctures , Humans , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Equipment Design , Heart Septum/surgery , Heart Septum/diagnostic imaging , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Treatment Outcome
4.
Catheter Cardiovasc Interv ; 104(4): 870-877, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39049480

ABSTRACT

Mitral regurgitation (MR) is the most common heart valve disease, and transcatheter edge-to-edge repair (TEER) has been recommended as a therapy for severe MR patients by guidelines. The classic Carpentier classification used to guide surgical mitral valve repair but is inadequate for mitral TEER (M-TEER). We herein proposed a new modified Carpentier classification named after "type + segment," which is suitable for M-TEER. We shared our strategies in M-TEER procedure for screening and performing the M-TEER according to the new modified Carpentier classification.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Predictive Value of Tests , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/classification , Humans , Cardiac Catheterization/instrumentation , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Treatment Outcome , Severity of Illness Index , Echocardiography, Transesophageal
5.
Catheter Cardiovasc Interv ; 103(4): 618-625, 2024 03.
Article in English | MEDLINE | ID: mdl-38436540

ABSTRACT

BACKGROUND: Mitral annular calcification (MAC) has been an exclusion for many of the earlier pivotal trials that were instrumental in gaining device approval and indications for mitral transcatheter edge-to-edge repair (M-TEER). AIMS: To evaluate the impact of MAC on the procedural durability and success of newer generation MitraClip® systems (G3 and G4 systems). METHODS: Data were collected from Northwell TEER registry. Patients that underwent M-TEER with third or fourth generation MitraClip device were included. Patients were divided into -MAC (none-mild) and +MAC (moderate-severe) groups. Procedural success was defined as ≤ grade 2 + mitral regurgitation (MR) postprocedure, and durability was defined as ≤ grade 2 + MR retention at 1 month and 1 year. Univariate analysis compared outcomes between groups. RESULTS: Of 260 M-TEER patients, 160 were -MAC and 100 were +MAC. Procedural success was comparable; however, there were three patients who required conversion to cardiac surgery during the index hospitalization in the +MAC group versus none in the -MAC group (though this was not statistically significant). At 1-month follow-up, there were no significant differences in MR severity. At 1-year follow-up, +MAC had higher moderate-severe MR (22.1% vs. 7.5%; p = 0.002) and higher mean transmitral gradients (5.3 vs. 4.0 mmHg; p = 0.001) with no differences in mortality, New York Heart Association functional class or ejection fraction. CONCLUSION: In selective patients with high burden of MAC, contemporary M-TEER is safe, and procedural success is similar to patients with none-mild MAC. However, a loss of procedural durability was seen in +MAC group at 1-year follow-up. Further studies with longer follow-ups are required to assess newer mTEER devices and their potential clinical implications in patients with a high burden of MAC.


Subject(s)
Mitral Valve Insufficiency , Humans , Treatment Outcome , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Hospitalization , Registries , Technology
6.
Article in English | MEDLINE | ID: mdl-39295581

ABSTRACT

BACKGROUND: The prognostic significance of intraprocedural pulsed-wave Doppler analysis of pulmonary venous flow (PVF) during mitral transcatheter edge-to-edge repair (TEER) remains understudied. We aimed to investigate the prognostic value of systolic dominant-PVF (SD-PVF) morphology post-TEER. METHODS: In a retrospective analysis from December 2019 to December 2022, patients undergoing mitral TEER were categorized into SD-PVF and systolic blunting (SB)-PVF groups based on post-TEER morphology. The primary endpoint was a composite of all-cause mortality or heart failure hospitalization at 1 year. We investigated the association of PVF morphology post-TEER with the primary endpoint at 1 year using Cox regression and compared the prognostic accuracy of PVF variables through receiver operating characteristic (ROC) curve analysis. RESULTS: Among 187 patients (mean age 76.4 ± 10.5 years, 51.3% primary etiology), residual mitral regurgitation (MR) ≤mild was observed in 147 (82.4%) patients and 105 (56.2%) had SD-PVF post-TEER. Patients with SD-PVF had a lower incidence of >2+ residual MR after clip deployment, at 30 days (2.1% vs. 13.1%; p = 0.005) and at 1 year (1.4% vs. 9%; p = 0.08). SD-PVF post-TEER was independently associated with the primary endpoint (HR = 0.59, 95% CI = 0.39-0.87; p = 0.009). ROC curve analysis of the prognostic accuracy of SD-PVF demonstrated an AUC of 0.64 (95% CI = 0.54-0.73), comparable to other quantitative measures of PVF. CONCLUSION: Assessing PVF morphology after clip deployment offers a simple prognostic tool for patients undergoing mitral TEER. Multicenter cohorts will be necessary to further investigate its prognostic value.

7.
Article in English | MEDLINE | ID: mdl-39300820

ABSTRACT

In the modern era of structural heart interventions, the total number of transseptal procedures is growing exponentially, thus increasing the rate and need for management of iatrogenic atrial septal defects (iASDs). To date, there are no official guidelines on the assessment and management of iASDs, due to inconclusive evidence on whether patients benefit more from the percutaneous closure of iASD than from conservative management and vigorous follow-up. Despite the abundance of observational studies on iASDs, there is still a lack of randomized studies. Evidence so far show that percutaneous closure is no superior over conservative treatment in patients with iASDs, however, it has been demonstrated that patients with spontaneous closure of iASDs experience less heart failure (HF) hospitalizations. On the other hand, researchers have investigated the beneficial nature of interatrial shunt therapy in patients with HFpEF and, more recently, with HFrEF, due to the presumed hemodynamic benefits. Herein, we provide an updated review of relevant literature, focusing on iASD persistence rates, predicting factors for their persistence, and clinical outcomes of iASD persistence, to summarize available evidence and discuss future directions in the field.

8.
Circ J ; 88(4): 531-538, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38008428

ABSTRACT

BACKGROUND: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).Methods and Results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11-1.32; P=0.13). CONCLUSIONS: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Treatment Outcome , Proportional Hazards Models , Cardiac Catheterization
9.
Circ J ; 88(4): 519-527, 2024 03 25.
Article in English | MEDLINE | ID: mdl-38325820

ABSTRACT

BACKGROUND: We investigated the efficacy of left ventricular (LV) myocardial damage by native T1mapping obtained with cardiac magnetic resonance (CMR) for patients undergoing transcatheter edge-to-edge repair (TEER). METHODS AND RESULTS: We studied 40 symptomatic non-ischemic heart failure (HF) patients and ventricular functional mitral regurgitation (VFMR) undergoing TEER. LV myocardial damage was defined as the native T1Z-score, which was converted from native T1values obtained with CMR. The primary endpoint was defined as HF rehospitalization or cardiovascular death over 12 months after TEER. Multivariable Cox proportional hazards analysis showed that the native T1Z-score was the only independent parameter associated with cardiovascular events (hazard ratio 3.40; 95% confidential interval 1.51-7.67), and that patients with native T1Z-scores <2.41 experienced significantly fewer cardiovascular events than those with native T1Z-scores ≥2.41 (P=0.001). Moreover, the combination of a native T1Z-score <2.41 and more severe VFMR (effective regurgitant orifice area [EROA] ≥0.30 cm2) was associated with fewer cardiovascular events than a native T1Z-score ≥2.41 and less severe VFMR (EROA <0.30 cm2; P=0.002). CONCLUSIONS: Assessment of baseline LV myocardial damage based on native T1Z-scores obtained with CMR without gadolinium-based contrast media is a valuable additional parameter for better management of HF patients and VFMR following TEER.


Subject(s)
Cardiomyopathies , Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Heart Ventricles , Heart , Contrast Media , Cardiomyopathies/diagnostic imaging , Treatment Outcome
10.
Echocardiography ; 41(6): e15861, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38853674

ABSTRACT

BACKGROUND: Transesophageal echocardiography (TEE) is primarily used to guide transcatheter structural heart interventions, such as tricuspid transcatheter edge-to-edge repair (TEER). Although TEE has a good safety profile, it is still an invasive imaging technique that may be associated with complications, especially when performed during long transcatheter procedures or on frail patients. The aim of this study was to assess TEE-related complications during tricuspid TEER. METHODS: This is a prospective study enrolling 53 patients who underwent tricuspid TEER for severe tricuspid regurgitation (TR). TEE-related complications were assessed clinically and divided into major (life-threatening, major bleeding requiring transfusions or surgery, organ perforation, and persistent dysphagia) and minor (perioral hypesthesia, < 24 h dysphagia/odynophagia, minor intraoral bleeding and hematemesis not requiring transfusion) RESULTS: The median age of the patient population was 79 years; 43.4% had severe, 39.6% massive, and 17.6% torrential TR. 62.3% of patients suffered from upper gastrointestinal disorders. Acute procedural success (APS) was achieved in 88.7% in a median device time of 36 min. A negative association was shown between APS and lead-induced etiology (r = -.284, p = .040), baseline TR grade (r = -.410, p = .002), suboptimal TEE view (r = -.349, p = .012), device time (r = -.234, p = .043), and leaflet detachment (r = -.496, p < .0001). We did not observe any clinical manifest major or minor TEE-related complications during the hospitalization. CONCLUSIONS: Our study reinforces the good safety profile and efficacy of TEE guidance during tricuspid TEER. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious complications. Furthermore, suboptimal intraprocedural TEE views are associated with lower TR reduction rates. HIGHLIGHTS: Transesophageal echocardiography is a crucial and safe technique for guiding transcatheter structural heart interventions. A mix of mid/deep esophageal and trans gastric views, as well as real-time 3D imaging is generally used to guide the procedure. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious problems. A shorter device time is associated with more rarely probe-related complications. Suboptimal intraprocedural TEE views are associated with lower TR reduction rates.


Subject(s)
Echocardiography, Transesophageal , Tricuspid Valve Insufficiency , Tricuspid Valve , Humans , Echocardiography, Transesophageal/methods , Female , Male , Prospective Studies , Tricuspid Valve Insufficiency/surgery , Aged , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Treatment Outcome , Aged, 80 and over
11.
Curr Cardiol Rep ; 26(6): 459-474, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38884853

ABSTRACT

PURPOSE OF REVIEW: Patients with severe tricuspid regurgitation (TR) are at risk for significant morbidity and mortality. Transcatheter tricuspid valve interventions (TTVI) may offer patients less invasive treatment alternatives to surgery. This review evaluates the most common class of device currently used worldwide to treat TR, tricuspid transcatheter edge-to-edge repair (T-TEER) and orthotopic transcatheter tricuspid valve replacement (TTVR), both of which are now approved in the USA and Europe. RECENT FINDINGS: The first pivotal randomized clinical trial, TRILUMINATE, demonstrated that T-TEER can safely reduce TR and is associated with improved health status outcomes. However, results of this trial have raised questions about whether this device can provide sufficient TR reduction to impact clinical outcomes. Orthotopic TTVR has recently gained attention with initial data suggesting near-complete TR elimination. The current review examines the technical features and anatomic limitations of the most commonly used devices for T-TEER and orthotopic TTVR, discusses the current clinical data for these devices, and offers a theoretical construct for device selection.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Tricuspid Valve , Humans , Tricuspid Valve Insufficiency/surgery , Cardiac Catheterization/methods , Cardiac Catheterization/instrumentation , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Treatment Outcome , Randomized Controlled Trials as Topic
12.
Curr Cardiol Rep ; 2024 Oct 07.
Article in English | MEDLINE | ID: mdl-39373959

ABSTRACT

PURPOSE OF REVIEW: This review aims to highlight the current evidence on the use of cerebral embolic protection devices (CEPD) in left atrial and transcatheter mitral valve procedures. It also aims to summarize the antithrombotic management of patients undergoing such procedures. RECENT FINDINGS: Ischemic stroke is one of the most devastating complications of structural heart procedures. The manifestation of periprocedural stroke can range from asymptomatic and detectable only through brain imaging to major stroke with neurological deficits. CEP devices were initially developed to mitigate the risk of stroke associated with transcatheter aortic valve replacement (TAVR). However, the efficacy of such devices during different cardiac interventions is yet to be fully demonstrated, especially in left atrial appendage closure (LAAO), and mitral valve interventions. Few studies demonstrated that the risk of periprocedural strokes after LAAO and mitral valve interventions is not negligible and is highest during the periprocedural period and then falls. The majority of patients undergoing those procedures have cerebral ischemic injuries detected on diffusion-weighted magnetic resonance imaging (DW-MRI). Moreover, a reasonable number of those patients had debris embolization on the filters of the CEPD. Pharmacological therapy with antithrombotic agents before, during, or after structural heart interventions is crucial and should be tailored to each patient's risk of bleeding and ischemia. Close monitoring that includes a full neurological assessment and frequent follow-up visits with cardiac echocardiography are important. The risk of periprocedural stroke in left atrial and transcatheter mitral valve procedures is not negligible. Pharmacological therapy with antithrombotic agents before, during, or after structural heart interventions is important to mitigate the risk of stroke, especially the long-term risk. More prospective studies are needed to assess the efficacy of CEPD in such procedures.

13.
Eur Heart J ; 44(44): 4650-4661, 2023 Nov 21.
Article in English | MEDLINE | ID: mdl-37632738

ABSTRACT

BACKGROUND AND AIMS: Guideline-directed medical therapy (GDMT) is recommended before mitral valve transcatheter edge-to-edge repair (MTEER) in patients with heart failure (HF) and severe functional mitral regurgitation (FMR). Whether MTEER is being performed on the background of optimal GDMT in clinical practice is unknown. METHODS: Patients with left ventricular ejection fraction (LVEF) < 50% who underwent MTEER for FMR from 23 July 2019 to 31 March 2022 in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry were identified. Pre-procedure GDMT utilization was assessed. Cox proportional hazards models were constructed to evaluate associations between pre-MTEER therapy (no/single, double, or triple therapy) and risk of 1-year mortality or HF hospitalization (HFH). RESULTS: Among 4199 patients across 449 sites, beta-blockers, angiotensin-converting enzyme inhibitors/angiotensin receptor blockers, mineralocorticoid receptor antagonists, and angiotensin receptor-neprilysin inhibitors were used in 85.1%, 44.4%, 28.6%, and 19.9% before MTEER, respectively. Triple therapy was prescribed for 19.2%, double therapy for 38.2%, single therapy for 36.0%, and 6.5% were on no GDMT. Significant centre-level variation in the proportion of patients on pre-intervention triple therapy was observed (0%-61%; adjusted median odds ratio 1.48 [95% confidence interval (CI) 1.25-3.88]; P < .001). In patients eligible for 1-year follow-up (n = 2014; 341 sites), the composite rate of 1-year mortality or HFH was lowest in patients prescribed triple therapy (23.0%) compared with double (24.8%), single (35.7%), and no (41.1%) therapy (P < .01 comparing across groups). Associations persisted after accounting for relevant clinical characteristics, with lower risk in patients prescribed triple therapy [adjusted hazard ratio (aHR) 0.73, 95% CI .55-.97] and double therapy (aHR 0.69, 95% CI .56-.86) before MTEER compared with no/single therapy. CONCLUSIONS: Under one-fifth of patients with LVEF <50% who underwent MTEER for FMR in this US nationwide registry were prescribed comprehensive GDMT, with substantial variation across sites. Compared with no/single therapy, triple and double therapy before MTEER were independently associated with reduced risk of mortality or HFH 1 year after intervention.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Treatment Outcome , Stroke Volume , Ventricular Function, Left , Mitral Valve Insufficiency/etiology , Heart Valve Prosthesis Implantation/methods , Heart Failure/etiology , Registries
14.
Heart Fail Clin ; 20(4): 437-444, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39216928

ABSTRACT

Transcatheter mitral valve repair should be considered for patients with severe secondary mitral regurgitation with symptomatic heart failure with reduced ejection fraction for symptom improvement and survival benefit. Patients with a higher severity of secondary mitral regurgitation relative to the degree of left ventricular dilation are more likely to benefit from transcatheter mitral valve repair. A multidisciplinary Heart Team should participate in patient selection for transcatheter mitral valve therapy.


Subject(s)
Cardiac Catheterization , Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Stroke Volume , Humans , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/surgery , Heart Failure/physiopathology , Heart Failure/therapy , Stroke Volume/physiology , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Mitral Valve/surgery , Mitral Valve/physiopathology , Patient Selection
15.
Rev Cardiovasc Med ; 24(5): 138, 2023 May.
Article in English | MEDLINE | ID: mdl-39076737

ABSTRACT

Background: The MitraClip G4 system is the latest version of the transcatheter edge-to-edge repair (TEER) system for mitral regurgitation (MR). We aimed to investigate the impact of the new system on routine clinical practice and patient outcomes in the treatment of primary MR. Methods: Consecutive patients with primary MR who underwent TEER with either the MitraClip G2 or G4 between 2018 and 2021 were enrolled from a single center registry. Baseline clinical and echocardiographic characteristics as well as procedural and clinical outcomes up to 1 year were compared between groups. Technical and device success were defined in accordance with the Mitral Valve Academic Research Consortium criteria. Results: Among 71 patients with primary MR, 34 were treated with G2 and 37 were treated with G4. Patients treated with G4 had lower surgical risk (7.74 [5.04, 14.97] vs. 5.26 [3.98, 6.40]; p < 0.01) than those with G2. There were no significant differences in other baseline clinical variables between groups. On baseline echocardiography, MR volume and flail gap were significantly greater in the G4 group than in the G2 group (regurgitant volume: 63 [41-76] mL vs. 68 [62-84] mL; p = 0.04, flail gap: 4.5 [3.5-5.5] mm vs. 5.4 [4.5-7.1] mm; p = 0.04). Technical success was achieved in over 95% of both groups with no significant difference (p > 0.99). Device success was achieved in 61.8% of the G2 group, while in 70.3% of the G4 group (p = 0.47). Post-procedural MR severity was comparable (p = 0.42) and there was no significant difference in the occurrence of mitral stenosis (p = 0.61) between groups. Among patients who reached 1-year follow-up (n = 54), there was no significant difference between groups in a composite endpoint of death or heart failure rehospitalization (10.5% vs. 20.2%; HR 0.61; 95% CI 0.17-2.22; p = 0.45). Residual heart failure symptoms (NYHA ≥ 3) at 1 year were observed in 3.7% of the G2 group, while no patient in the G4 group (p > 0.99). Conclusions: The MitraClip G4 system achieved comparable device outcomes to the early-generation device (G2), despite treating more severe primary MR with a larger flail gap.

16.
Rev Cardiovasc Med ; 24(1): 15, 2023 Jan.
Article in English | MEDLINE | ID: mdl-39076866

ABSTRACT

Background: Transcatheter edge-to-edge repair of mitral valve (M-TEER) is reasonable consideration in symptomatic patients with severe degenerative mitral regurgitation (MR) who are at high or prohibitive risk of surgical repair or replacement. In symptomatic patients on maximally tolerated medical therapy with severe secondary MR from left ventricular systolic dysfunction, M-TEER is reasonable therapeutic option. Methods: In this review, we present a comprehensive overview of the most recent literature and considerations for M-TEER in patients excluded from key trials. These include patients with cardiogenic shock, acute ischemic MR, atrial functional MR, failed surgical mitral valve prosthesis and pulmonary hypertension. Conclusions: M-TEER is feasible and a reasonable alternative option for these patient populations with a significant clinical benefit. However, randomized clinical trials are needed to ascertain findings from these observational studies.

17.
Catheter Cardiovasc Interv ; 102(4): 751-760, 2023 10.
Article in English | MEDLINE | ID: mdl-37579199

ABSTRACT

BACKGROUND: Transcatheter edge-to-edge repair (TEER) may have potential benefits in the treatment of atrial functional mitral regurgitation (AFMR), but robust evidence is currently lacking. We conducted a systematic review and meta-analysis to investigate the clinical outcomes of TEER for AFMR, including comparisons to ventricular functional MR (VFMR). METHODS: MEDLINE and EMBASE were searched through January 2023 to identify studies eligible for analysis. The primary outcome was postprocedural MR severity. Postprocedural New York Heart Association (NYHA) functional class classification and all-cause mortality were also evaluated. Outcomes were stratified into short term (postprocedure to 6 months) and long term (6 months to 2 years). RESULTS: A total of eight observational studies met the inclusion criteria, enrolling 539 AFMR and 3486 VFMR patients. Postprocedural MR grade ≤2 in the AFMR group was observed in 93.7% (454/491 patients; 95% confidence interval (CI), 91.1%-96.2%, I2 = 24.3%) and 97.1% (89/93 patients; 95% CI, 92.9%-100%, I2 = 26.4%) in short- and long-term follow-up, respectively. There was no difference in the rates of postprocedural MR grade ≤2 between AFMR and VFMR either in short-term (risk ratio [RR], 1.00 [95% CI, 0.95-1.06]; p = 0.90; I2 = 53%) or long-term follow-up (RR, 1.08 [95% CI, 0.89-1.32]; p = 0.44; I2 = 22%). Similarly, no difference was observed between AFMR and VFMR in the rates of postprocedural NYHA class ≤2 or all-cause mortality. CONCLUSION: TEER provides similar clinical outcomes for AFMR and VFMR. A high rate of MR grade ≤2 was observed in patients at both short- and long-term follow-ups. Further prospective studies with TEER versus medical therapy and/or rhythm control for AFMR are warranted.


Subject(s)
Atrial Fibrillation , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Prospective Studies , Treatment Outcome , Heart Atria , Heart Valve Prosthesis Implantation/adverse effects
18.
Catheter Cardiovasc Interv ; 101(6): 1120-1127, 2023 05.
Article in English | MEDLINE | ID: mdl-37017419

ABSTRACT

BACKGROUND: Improvement in left atrial pressure (LAP) during transcatheter edge-to-edge repair (TEER) is associated with improved outcomes. We sought to investigate the predictors of optimal hemodynamic response to TEER. METHODS: We identified patients who underwent TEER at Mayo Clinic between May 2014 and February 2022. Patients with missing LAP data, an aborted procedure, and those undergoing a concomitant tricuspid TEER were excluded. We performed a logistic regression analysis to identify predictors of optimal hemodynamic response to TEER (defined as LAP ≤ 15 mmHg). RESULTS: A total of 473 patients were included (Mean age 78.5 ± 9.4 years, 67.2% males). Overall, 195 (41.2%) achieved an optimal hemodynamic response after TEER. Patients who did not achieve an optimal response had higher baseline LAP (20.0 [17-25] vs. 15.0 [12-18] mmHg, p < 0.001), higher prevalence of AF (68.3% vs. 55.9%, p = 0.006), functional MR (47.5% vs. 35.9%, p = 0.009), annular calcification (41% vs. 29.2%, p = 0.02), lower left ventricular EF (55% vs. 58%, p = 0.02), and more frequent postprocedural severe MR (11.9% vs. 5.1%, p = 0.02) and elevated mitral gradient >5 mmHg (30.6% vs. 14.4%, p < 0.001). In the multivariate logistic regression analysis, AF (OR = 0.58; 95% CI = 0.35-0.96; p = 0.03), baseline LAP (OR = 0.80; 95% CI = 0.75-0.84; p < 0.001) and postprocedural mitral gradient <5 mmHg (OR = 0.35; 95% CI = 0.19-0.65; p < 0.001), were independent predictors of achieving an optimal hemodynamic response. In the multivariate model, residual MR was not independently associated with optimal hemodynamic response. CONCLUSIONS: Optimal hemodynamic response is achieved in 4 in 10 patients undergoing TEER. AF, higher baseline LAP, and higher postprocedural mitral gradient were negative predictors of optimal hemodynamic response after TEER.


Subject(s)
Calcinosis , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Male , Humans , Aged , Aged, 80 and over , Female , Treatment Outcome , Hemodynamics , Heart Ventricles , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Heart Valve Prosthesis Implantation/adverse effects
19.
Catheter Cardiovasc Interv ; 102(1): 138-144, 2023 07.
Article in English | MEDLINE | ID: mdl-37161909

ABSTRACT

Papillary muscle rupture (PMR) is a rare complication of acute myocardial infarction (AMI) associated with high mortality and morbidity. Surgery is the gold-standard treatment for these patients, but it is burdened by a high perioperative risk due to hemodynamic instability. Mitral transcatheter edge-to-edge repair (M-TEER) was reported to be safe and effective in unstable patients with significant mitral regurgitation. However, data in patients with post-AMI PMR are limited to a few case reports. In this review, we summarized all data available regarding percutaneous treatment of post-AMI PMR. These results show that M-TEER is safe and effective in this setting with low in-hospital mortality and complications and high rate of significant mitral regurgitation reduction.


Subject(s)
Heart Failure , Heart Rupture, Post-Infarction , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Myocardial Infarction , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Papillary Muscles/diagnostic imaging , Papillary Muscles/surgery , Heart Rupture, Post-Infarction/diagnostic imaging , Heart Rupture, Post-Infarction/etiology , Treatment Outcome , Myocardial Infarction/complications , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Failure/surgery
20.
Echocardiography ; 40(2): 147-152, 2023 02.
Article in English | MEDLINE | ID: mdl-36636809

ABSTRACT

Edge-to-edge tricuspid transcatheter repair requires extensive echocardiographic planning before the procedure. Sometimes, anatomic features may anticipate a suboptimal result. For this reason, a tailored strategy is the key to the procedural success. We report a case of massive tricuspid regurgitation due to multiple complex mechanisms that was successfully treated by clipping the antero-septal commissure to restore functional coaptation of the valve leaflets at multiple sites.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Cardiac Catheterization , Treatment Outcome , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery
SELECTION OF CITATIONS
SEARCH DETAIL