Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 96
Filter
Add more filters

Publication year range
1.
Eur Arch Otorhinolaryngol ; 277(3): 669-677, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31758308

ABSTRACT

OBJECTIVES: The use of standardized outcome parameters is essential for the comparability of clinical studies. Pure-tone audiometry and speech audiometry are widely used, but there is no systematic evaluation of the outcome parameters in clinical application. Nevertheless, there is presumably a great heterogeneity especially in the field of speech audiometry. This study presents a snapshot of the current situation of documentation and usage of outcome parameters in otologic research. STUDY DESIGN: Retrospective study of existing literature analyzing common speech audiometric test material and procedure MAIN OUTCOME MEASURES: Intervention Studies from 2012 to 2016 concerning hearing ability were eligible for evaluation. Studies were analyzed with regard to study design, pathology and intervention, speech audiometric parameters, pure-tone audiometry, implementation of reporting standards and journal related data. RESULTS: 279 studies were included. Over 50% of the analyzed studies lacked proper documentation. In the remaining studies, there was a broad variance concerning the documented speech audiometric parameters, most often with a fixed presentation level of 65 dB SPL. CONCLUSION: The lack of generally used standards for reporting hearing outcomes makes it difficult to compare results of different clinical studies. An adequate description of the methods would be a first and important step in improving reports on audiological outcomes.


Subject(s)
Audiometry, Speech/standards , Clinical Studies as Topic/standards , Hearing Loss/diagnosis , Hearing Loss/therapy , Outcome Assessment, Health Care/standards , Quality of Health Care/standards , Audiometry, Pure-Tone/standards , Humans , Retrospective Studies
2.
J Acoust Soc Am ; 145(6): 3640, 2019 06.
Article in English | MEDLINE | ID: mdl-31255150

ABSTRACT

The revision of International Organization for Standardization (ISO) standard ISO 1999 [(1971). International Organization of Standardization, Geneva, Switzerland)] in 1990 was based on two noise and hearing study databases, one presented by Burns and Robinson [(1970). Hearing and Noise in Industry (Her Majesty's Stationary Office, London)] and the other by Passchier-Vermeer [(1968). Report No. 35 and Supplement to Report No. 35 (Institute for Public Health Engineering, the Netherlands)]. However, the mathematical expression of these data in ISO 1999 neither closely predicts the distribution of hearing threshold levels in these two databases nor those in the National Institute for Occupational Safety and Health database. As a result, lower estimates of the risk of noise-induced hearing impairment are found using ISO 1999. An explanation of the revision is needed to justify these lower risk values.


Subject(s)
Audiometry, Pure-Tone/standards , Hearing Loss, Noise-Induced/physiopathology , Hearing/physiology , Noise, Occupational/adverse effects , Adult , Auditory Threshold/physiology , Female , Hearing Loss, Noise-Induced/etiology , Humans , Male , Occupational Diseases/etiology , Occupational Diseases/physiopathology
3.
Undersea Hyperb Med ; 46(3): 227-241, 2019.
Article in English | MEDLINE | ID: mdl-31394594

ABSTRACT

BACKGROUND: Audiology clinics have many tools available to evaluate auditory and vestibular complaints. However, many tools lack established normative ranges across the life span. We conducted this study to establish reference ranges across the life span for audiology/vestibular measures commonly used to evaluate patients with traumatic brain injury. MATERIALS AND METHODS: In this repeated measures study, 75 adults, ages 18-65 years, without a history of traumatic brain injury, underwent robust auditory/vestibular evaluations three times over six months, including rotational chair, videonystagmography, computerized dynamic posturography, vestibular evoked myogenic potentials, and retinal fundoscopy. RESULTS: Age effect was notable for transient evoked otoacoustic emissions, pure-tone audiometry, auditory brainstem response, auditory middle latency response, and auditory-steady state response at 4000 hertz (Hz). Older participants (50-65 years) were more likely to have delayed latency horizontal saccades, positional nystagmus, slowed lower-extremity motor control responses, and delayed latency ocular vestibular evoked myogenic potentials. Low to mid-frequency horizontal (0.003-4 Hz) and mid-frequency vertical (1-3 Hz) vestibulo-ocular reflex, otolith-mediated reflexes, dynamic visual acuity and balance measures were generally not influenced by age. Females had larger static subjective visual testing offset angles, longer cervical vestibular evoked myogenic potential P1 latency, faster velocity horizontal saccades, and quicker motor control latency for large backward translations than age-matched males. CONCLUSION: These reference ranges can be used to discern impairment within the auditory and vestibular pathway following traumatic brain injury in young to middle-aged adults. ID: TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT01925963.


Subject(s)
Brain Injuries, Traumatic/physiopathology , Hearing Tests/standards , Vestibular Function Tests/standards , Adolescent , Adult , Age Factors , Aged , Audiometry, Evoked Response/standards , Audiometry, Pure-Tone/standards , Brain Injuries, Traumatic/complications , Evoked Potentials, Auditory, Brain Stem , Female , Fundus Oculi , Hearing Tests/methods , Humans , Male , Middle Aged , Motor Activity , Nystagmus, Physiologic , Otoscopy/methods , Postural Balance , Prospective Studies , Reference Values , Reflex, Acoustic , Rotation , Saccades , Sex Factors , Time Factors , Vestibular Evoked Myogenic Potentials , Vestibular Function Tests/methods , Visual Acuity , Young Adult
4.
Int Arch Occup Environ Health ; 91(7): 877-885, 2018 10.
Article in English | MEDLINE | ID: mdl-29959525

ABSTRACT

PURPOSE: To validate the accuracy of an internet-based speech-in-noise hearing screening test for high-frequency hearing loss (HFHL) 'Occupational Earcheck (OEC)' incorporating an automatic conditional rescreening, in an occupationally noise-exposed population. Secondary objectives were to assess the effects of age on test accuracy measures, and to assess the test accuracy for different degrees of HFHL. METHODS: A study was conducted on cross-sectional data of occupational audiometric examinations, including the index test OEC and reference standard pure-tone air conduction audiometry, of 80 noise-exposed workers. Sensitivity, specificity, and likelihood ratios were calculated for the OEC, after automatic conditional rescreening, for a younger and an older age group, and for two degrees of HFHL (HFHL25: PTA3,4,6 ≥ 25 dB HL, and HFHL35: PTA3,4,6 ≥ 35 dB HL, both for at least one ear). RESULTS: Test specificity for HFHL25 after a single test was 63%, and improved to 93% after the automatic conditional rescreen. Test sensitivity for HFHL25 decreased from 65% to 59%. Test sensitivity and specificity including automatic conditional rescreening for HFHL35 was 94% and 90%, respectively. The positive likelihood ratio for HFHL25 was 8.4, and for HFHL35 9.4. The negative likelihood ratio for HFHL35 was below 0.1. CONCLUSIONS: The OEC is an appropriate screening test, especially for HFHL35. Normal-hearing workers who obtained a positive test result for the first test for one or two ears, benefit from having an automatic rescreen, resulting in an improvement of the test specificity, and hence prevent unnecessary referral.


Subject(s)
Audiometry, Pure-Tone/standards , Hearing Loss, Noise-Induced/diagnosis , Hearing Tests/standards , Mass Screening/standards , Occupational Diseases/diagnosis , Adult , Audiometry, Pure-Tone/methods , Cross-Sectional Studies , Female , Hearing Loss, Noise-Induced/etiology , Hearing Tests/methods , Humans , Male , Mass Screening/methods , Middle Aged , Noise, Occupational/adverse effects , Occupational Diseases/etiology , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity
5.
Br J Hist Sci ; 51(1): 123-146, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29233232

ABSTRACT

The provision of standardized hearing aids is now considered to be a crucial part of the UK National Health Service. Yet this is only explicable through reference to the career of a woman who has, until now, been entirely forgotten. Dr Phyllis Margaret Tookey Kerridge (1901-1940) was an authoritative figure in a variety of fields: medicine, physiology, otology and the construction of scientific apparatus. The astounding breadth of her professional qualifications allowed her to combine features of these fields and, later in her career, to position herself as a specialist to shape the discipline of audiometry. Rather than framing Kerridge in the classic 'heroic-woman' narrative, in this article we draw out the complexities of her career by focusing on her pursuit of standardization of hearing tests. Collaboration afforded her the necessary networks to explore the intricacies of accuracy in the measurement of hearing acuity, but her influence was enhanced by her ownership of Britain's first Western Electric (pure-tone) audiometer, which she placed in a specially designed and unique 'silence room'. The room became the centre of Kerridge's hearing aid clinic that, for the first time, allowed people to access free and impartial advice on hearing aid prescription. In becoming the guardian expert and advocate of the audiometer, Kerridge achieved an objectively quantified approach to hearing loss that eventually made the latter an object of technocratic intervention.


Subject(s)
Audiometry/history , Deafness/history , Hearing Aids/history , Audiometry/standards , Audiometry, Pure-Tone/history , Audiometry, Pure-Tone/instrumentation , Audiometry, Pure-Tone/standards , Biomedical Research/history , Deafness/diagnosis , Deafness/rehabilitation , Hearing Aids/standards , History, 20th Century , Humans , United Kingdom
6.
HNO ; 65(3): 228-236, 2017 Mar.
Article in German | MEDLINE | ID: mdl-28054098

ABSTRACT

BACKGROUND: In communication situations with multiple speakers, speech recognition is adversely affected by energetic masking (EM) and informational masking (IM). IM characterizes masking effects caused by irrelevant information from competing speakers. This work investigates an approach to assess IM based on the Oldenburg Sentence Test (OLSa). Furthermore, the influence of interaural time differences (ITD) and aging effects on IM are considered. MATERIALS AND METHODS: IM was measured by superimposing two sentences from the OLSa. The beginning of the target sentence was indicated by the keyword "Stefan". To segregate between target and masker sentences, ITDs from 50 to 400 µs were included. The participants were asked to selectively attend to the target sentence and repeat back the spoken words. Potential factors associated with speech recognition results were assessed by an auditory measure of temporal fine structure and a neuropsychological profile. 16 normal-hearing listeners between 18 and 77 years of age participated in the study. RESULTS: Despite the clinically normal-hearing participants, the analysis showed a significant relationship between speech recognition outcome and pure-tone thresholds. All participants benefited from small ITDs between the target and masker sentence with regard to the unmasking of IM. The magnitude of unmasking could not be explained by any of the factors assessed in this study. Error analysis and the comparison to the literature reveal that the OLSa could be a useful tool to assess IM. Also in line with the current literature is the relationship between speech recognition outcome and pure-tone thresholds, as well as the strong effect of ITDs on the release from IM. CONCLUSION: Speech audiometric assessment of IM is of high relevance with regard to everyday communication situations. Due to its structure, the OLSa seems to be a useful tool for determining IM.


Subject(s)
Audiometry, Pure-Tone/methods , Audiometry, Pure-Tone/standards , Audiometry, Speech/methods , Audiometry, Speech/standards , Perceptual Masking/physiology , Speech Perception/physiology , Adolescent , Adult , Aged , Female , Germany , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Signal-To-Noise Ratio , Translating , Young Adult
7.
Int J Audiol ; 55(11): 616-22, 2016 11.
Article in English | MEDLINE | ID: mdl-27610920

ABSTRACT

OBJECTIVE: Evaluation of the Sennheiser HD 202 II supra-aural headphones as an alternative headphone to enable more affordable hearing screening. DESIGN: Study 1 measured the equivalent threshold sound pressure levels (ETSPL) of the Sennheiser HD 202 II. Study 2 evaluated the attenuation of the headphones. Study 3 determined headphone characteristics by analyzing the total harmonic distortion (THD), frequency response and force of the headband. STUDY SAMPLE: Twenty-five participants were included in study 1 and 15 in study 2 with ages ranging between 18 and 25. No participants were involved in study 3. RESULTS: The Sennheiser HD 202 II ETSPLs (250-16000 Hz) showed no significant effects on ETSPL for ear laterality, gender or age. Attenuation was not significantly different (p > 0.01) to TDH 39 except at 8000 Hz (p < 0.01). Maximum permissible ambient noise levels (MPANL) were specified accordingly. The force of the headband was 3.1N. THD measurements showed that between 500 and 8000 Hz intensities of 90 dB HL and higher can be reached without THD >3%. CONCLUSION: Sennheiser HD 202 II supra-aural headphones can be used as an affordable headphone for screening audiometry provided reported MPANLs, maximum intensities and ETSPL values are employed.


Subject(s)
Acoustic Stimulation/economics , Acoustic Stimulation/instrumentation , Acoustics/instrumentation , Audiometry, Pure-Tone/economics , Audiometry, Pure-Tone/instrumentation , Auditory Perception , Health Care Costs , Acoustic Stimulation/standards , Adolescent , Adult , Audiometry, Pure-Tone/standards , Auditory Threshold , Calibration , Equipment Design , Female , Humans , Male , Materials Testing , Predictive Value of Tests , Pressure , Reproducibility of Results , Sound , Young Adult
8.
HNO ; 64 Suppl 1: S1-6, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26607156

ABSTRACT

OBJECTIVE: Selecting subjects for clinical trials on hearing loss therapies relies on the patient meeting the audiological inclusion criteria. In studies on the treatment of idiopathic sudden sensorineural hearing loss, the patient's acute audiogram is usually compared with a previous audiogram, the audiogram of the non-affected ear, or a normal audiogram according to an ISO standard. Generally, many more patients are screened than actually fulfill the particular inclusion criteria. The inclusion criteria often require a calculation of pure-tone averages, selection of the most affected frequencies, and calculation of hearing loss differences. MATERIALS AND METHODS: A software tool was developed to simplify and accelerate this inclusion procedure for investigators to estimate the possible recruitment rate during the planning phase of a clinical trial and during the actual study. This tool is Microsoft Excel-based and easy to modify to meet the particular inclusion criteria of a specific clinical trial. The tool was retrospectively evaluated on 100 patients with acute hearing loss comparing the times for classifying automatically and manually. The study sample comprised 100 patients with idiopathic sudden sensorineural hearing loss. RESULTS AND CONCLUSION: The age- and sex-related normative audiogram was calculated automatically by the tool and the hearing impairment was graded. The estimated recruitment rate of our sample was quickly calculated. Information about meeting the inclusion criteria was provided instantaneously. A significant reduction of 30 % in the time required for classifying (30 s per patient) was observed.


Subject(s)
Audiometry, Pure-Tone/standards , Clinical Trials as Topic/standards , Diagnosis, Computer-Assisted/methods , Eligibility Determination/methods , Hearing Loss, Sensorineural/diagnosis , Software/standards , Algorithms , Diagnosis, Computer-Assisted/standards , Eligibility Determination/classification , Eligibility Determination/standards , Female , Germany , Hearing Loss, Sensorineural/classification , Humans , Machine Learning , Male , Middle Aged , Patient Selection , Pattern Recognition, Automated , Practice Guidelines as Topic , Programming Languages , Reproducibility of Results , Sensitivity and Specificity , Translating
9.
Am J Ind Med ; 58(12): 1311-8, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26443047

ABSTRACT

BACKGROUND: Physicians and audiologists are often asked to decide whether standard threshold shifts (STSs) are work-related; epidemiological data can inform these decisions. METHODS: Predictions of ISO (2013) for both age-related and noise-induced threshold shifts, for the 2, 3, and 4 kHz average used in calculating OSHA STSs, are presented, in tables, graphs, and an Excel spreadsheet calculator. Specifically, the ISO 1999 model estimates age-related thresholds based on age and sex; it estimates noise-induced threshold shifts based on noise level and duration. It specifies that to estimate the final hearing thresholds for a person of given percentile, age, sex, and noise exposure, the expected age-related threshold is to be added to the expected noise-induced threshold shift. Examples show how these data can predict the relative contributions of aging and occupational noise to an STS. RESULTS: Early-career STSs, especially with high levels of noise exposure, are more likely to be primarily noise-induced. After the first decade of exposure, most STSs will be primarily age-related. CONCLUSION: Given a worker's age, sex, and occupational noise exposure history, ISO 1999 estimates of the expected contributions of aging and noise can supplement clinical judgment.


Subject(s)
Audiometry, Pure-Tone/standards , Hearing Loss, Noise-Induced/etiology , Noise, Occupational/adverse effects , Occupational Diseases/etiology , Occupational Exposure/standards , Adult , Age Factors , Aged , Aging , Auditory Threshold , Female , Humans , Male , Middle Aged , Reference Standards
10.
Int J Audiol ; 54(11): 796-805, 2015.
Article in English | MEDLINE | ID: mdl-25938502

ABSTRACT

OBJECTIVE: This study examined the statistical properties of normal air-conduction thresholds obtained with automated and manual audiometry to test the hypothesis that thresholds are normally distributed and to examine the distributions for evidence of bias in manual testing. DESIGN: Four databases were mined for normal thresholds. One contained audiograms obtained with an automated method. The other three were obtained with manual audiometry. Frequency distributions were examined for four test frequencies (250, 500, 1000, and 2000 Hz). STUDY SAMPLE: The analysis is based on 317 569 threshold determinations of 80 547 subjects from four clinical databases. RESULTS: Frequency distributions of thresholds obtained with automated audiometry are normal in form. Corrected for age, the mean thresholds are within 1.5 dB of reference equivalent threshold sound pressure levels. Frequency distributions of thresholds obtained by manual audiometry are shifted toward higher thresholds. Two of the three datasets obtained by manual audiometry are positively skewed. CONCLUSIONS: The positive shift and skew of the manual audiometry data may result from tester bias. The striking scarcity of thresholds below 0 dB HL suggests that audiologists place less importance on identifying low thresholds than they do for higher-level thresholds. We refer to this as the Good enough bias and suggest that it may be responsible for differences in distributions of thresholds obtained by automated and manual audiometry.


Subject(s)
Audiometry, Pure-Tone/standards , Auditory Threshold , Databases as Topic , Humans
11.
Int J Audiol ; 54(8): 499-506, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25832123

ABSTRACT

OBJECTIVE: The aim of the present study was to provide thresholds data as a function of age for an otologically normal population in Spain, compared to the current ISO 7029 (2000) standard. DESIGN: A prospective study in an otologically screened population. STUDY SAMPLE: Data was collected from 1175 otologically-normal persons aged between 5 and 90 years. Inclusion criteria involved those listed in ISO 389-1 (1998) and the 8253-1 (2010). Suitability for inclusion was evaluated through interview, based on a questionnaire, and physical examination. RESULTS: The hearing thresholds decreased slightly from 125 to 2000 Hz. From 2000 Hz onwards the thresholds increased; this increase being more pronounced with increasing frequency and age. No statistically significant sex differences were found. The hearing threshold levels in the present study were higher (poorer) than the ones provided by ISO 7029 (2000). CONCLUSIONS: Results from this study suggest that the thresholds listed in ISO 7029 (2000) may be too restrictive, and could be useful in formulating the ISO 7029 update.


Subject(s)
Audiometry, Pure-Tone/standards , Auditory Threshold , Adolescent , Adult , Age Factors , Aged , Aged, 80 and over , Audiometry, Pure-Tone/statistics & numerical data , Child , Child, Preschool , Female , Healthy Volunteers , Humans , Male , Middle Aged , Prospective Studies , Reference Standards , Spain , Young Adult
12.
J Acoust Soc Am ; 136(4): 1821-30, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25324083

ABSTRACT

The ISO 7029 (2000) standard defines normative hearing thresholds H (dB hearing level) as a function of age Y (years), given by H = α(Y - 18)(2), up to 8 kHz. The purpose of this study was to determine reference thresholds above 8 kHz. Hearing thresholds were examined using pure-tone audiometry over the extended frequency range 0.125-16 kHz, and the acquired values were used to specify the optimal approximation of the dependence of hearing thresholds on age. A sample of 411 otologically normal men and women 16-70 years of age was measured in both ears using a high-frequency audiometer and Sennheiser HDA 200 headphones. The coefficients of quadratic, linear, polynomial and power-law approximations were calculated using the least-squares fitting procedure. The approximation combining the square function H = α(Y - 18)(2) with a power-law function H = ß(Y - 18)(1.5), both gender-independent, was found to be the most appropriate. Coefficient α was determined at frequencies of 9 kHz (α = 0.021), 10 kHz (α = 0.024), 11.2 kHz (α = 0.029), and coefficient ß at frequencies of 12.5 kHz (ß = 0.24), 14 kHz (ß = 0.32), 16 kHz (ß = 0.36). The results could be used to determine age-dependent normal hearing thresholds in an extended frequency range and to normalize hearing thresholds when comparing participants differing in age.


Subject(s)
Aging/psychology , Audiometry, Pure-Tone/standards , Auditory Threshold , Hearing , Acoustic Stimulation , Adolescent , Adult , Age Factors , Aged , Female , Humans , Least-Squares Analysis , Linear Models , Male , Middle Aged , Reference Values , Young Adult
13.
Int J Audiol ; 53(8): 531-45, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24749665

ABSTRACT

OBJECTIVE: The aim of the present study was to study patterns in the extended spectrum of the human hearing (0.125 to 20 kHz) in order to obtain reference thresholds. Then, we compare our values with existing results at extended high-frequencies (8 to 20 kHz) in an attempt to establish new standards for potential international adoption. DESIGN: A prospective study in a group of otologically healthy subjects. STUDY SAMPLE: A total of 645 subjects aged between 5 and 90 years were recruited. Pure-tone thresholds were determined for conventional and extended high-frequencies. RESULTS: There was an increase in the hearing thresholds as a function of frequency and age. For the 20 to 69 years old group, thresholds were lower in females than in males, especially at 12.5 and 16 kHz. Our threshold values are comparable to those presented in previous studies that used different instrumentation and populations. CONCLUSIONS: When comparing different studies the hearing thresholds were found to be similar. Therefore, it would be possible to establish international standard thresholds.


Subject(s)
Audiometry, Pure-Tone/standards , Adolescent , Adult , Age Factors , Aged , Aged, 80 and over , Child , Child, Preschool , Female , Healthy Volunteers , Humans , Male , Middle Aged , Reference Values , Young Adult
14.
Int J Audiol ; 53(10): 730-6, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24909592

ABSTRACT

OBJECTIVE: The aim of this study was to determine the effect of ambient noise on the accuracy of thresholds obtained using the KUDUwave portable clinical audiometer as compared to those obtained using a GSI-61 clinical audiometer in a sound booth. DESIGN: Pure-tone air conduction thresholds were obtained in three conditions: (1) with a clinical audiometer in a quiet sound booth, (2) with the KUDUwave in a quiet sound booth, and (3) with the KUDUwave with 40 dBA of background noise. STUDY SAMPLE: A total of 31 individuals ranging in age from 15 to 80 years participated in the study, 21 with normal hearing and ten with hearing loss. RESULTS: Eighty-nine percent of thresholds obtained with the KUDUwave in quiet, and 92% of thresholds obtained with the KUDUwave in background noise were within 5 dB of those obtained with the clinical audiometer. Accuracy was poorer at 250 Hz and 8000 Hz. CONCLUSION: Ambient noise typical of that found in a non-sound-treated room, did not affect the accuracy of air conduction hearing thresholds obtained with the KUDUwave. The KUDUwave may be a viable method of testing when a clinical audiometer and sound booth are not available.


Subject(s)
Audiometry, Pure-Tone/standards , Auditory Threshold , Hearing Loss/diagnosis , Noise , Adolescent , Adult , Aged , Aged, 80 and over , Audiometry, Pure-Tone/instrumentation , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Young Adult
15.
Int J Audiol ; 53(5): 345-51, 2014 May.
Article in English | MEDLINE | ID: mdl-24484267

ABSTRACT

OBJECTIVE: To form a normative set of responses to the GHABP questionnaire from a large regional dataset. DESIGN: Participants were asked to rate their hearing disability, handicap, hearing-aid (HA) use, HA benefit, HA satisfaction, and residual (aided) disability on a five-point scale for four situations: quiet conversation, television (TV) listening, noisy conversation, and group conversation. A subset of participants also estimated the time spent in these situations. STUDY SAMPLE: A group of 1574 adults with normal to profound hearing thresholds participated. RESULTS: There was a significant relationship between increasing perceived disability and increasing hearing loss as given by the better-ear audiometric average (BEA). Responses for HA measures did not vary greatly with hearing loss: HA use was reported as high, whereas residual disability, HA benefit, and satisfaction were all reported on average as moderate. CONCLUSIONS: The results can be used as a normative dataset with which to evaluate individual responses in the clinic, where the GHABP provides a useful short-form questionnaire to engage the patient. The lack of systematic changes in hearing-aid related responses shows room for improvement in the benefit afforded by amplification.


Subject(s)
Correction of Hearing Impairment/standards , Hearing Aids/standards , Hearing Loss, Bilateral/rehabilitation , Hearing Loss, Unilateral/rehabilitation , Prosthesis Fitting/standards , Surveys and Questionnaires/standards , Adolescent , Adult , Aged , Aged, 80 and over , Audiometry, Pure-Tone/standards , Databases, Factual/standards , Female , Humans , Male , Middle Aged , Quality of Life , Young Adult
16.
Int J Audiol ; 53(5): 309-17, 2014 May.
Article in English | MEDLINE | ID: mdl-24495275

ABSTRACT

OBJECTIVES: To investigate auditory dysfunction in patients with tinnitus and normal hearing thresholds using two sensitive audiological measures. DESIGN: The study was designed to investigate the characteristics of Audioscan and DPOAE tests in tinnitus patients with normal hearing thresholds. Audioscan and DPOAE notches were analysed and compared. All tests were performed in a sound-treated chamber or in a sound-treated room. STUDY SAMPLE: Forty-five tinnitus patients with normal hearing thresholds were examined following a written clinical protocol. RESULTS: The averaged hearing levels obtained from tinnitus participants were significantly worse at high frequencies than those derived from the normative data. There was a significantly higher prevalence of Audioscan and DPOAE notches, whose central frequencies matched tinnitus frequencies in the mid-frequency regions, but not in the low- and high-frequency regions. A significant correlation was found between the centre frequencies of the Audioscan notches and the DPOAE notches from 500 to 4000 Hz. CONCLUSION: Tinnitus in different frequency regions may be associated with different underlying mechanisms of tinnitus generation. Some negative results on the Audioscan and DPOAE notches matching tinnitus pitches may be due to a limited set of discrete frequencies used for the tinnitus pitch matching test.


Subject(s)
Audiometry, Pure-Tone/methods , Auditory Threshold/physiology , Otoscopy/methods , Pitch Discrimination/physiology , Tinnitus/diagnosis , Tinnitus/physiopathology , Adult , Audiometry, Pure-Tone/standards , Cochlear Diseases/complications , Cochlear Diseases/diagnosis , Cochlear Diseases/physiopathology , Female , Hearing/physiology , Humans , Male , Middle Aged , Otoacoustic Emissions, Spontaneous/physiology , Otoscopy/standards , Reproducibility of Results , Severity of Illness Index , Tinnitus/etiology , Young Adult
17.
HNO ; 62(10): 735-45, 2014 Oct.
Article in German | MEDLINE | ID: mdl-25231698

ABSTRACT

A specific quality assurance questionnaire concerned with the provision of hearing aids was introduced that assesses elements of patient satisfaction within Germany's statutory healthcare system. A questionnaire-based assessment is now relevant for all physicians involved in the care of statutorily insured patients in Germany. The APHAB (Abbreviated Profile of Hearing Aid Benefit) questionnaire is the most widely used. The APHAB assesses several different situations: the normal hearing situation, hearing in noise, comprehension of speech in situations of echo or reverberation and hearing in loud situations. The APHAB questionnaire-based patient evaluation of the benefit of hearing aids represents the third pillar of audiological diagnostics, alongside classical pure-tone and speech audiometry. The objective of the APHAB database is to allow evaluation of individual patient data on the basis of a larger volume of data.


Subject(s)
Databases as Topic/organization & administration , Hearing Aids/standards , Hearing Loss/rehabilitation , National Health Programs , Patient Satisfaction , Quality Assurance, Health Care/standards , Surveys and Questionnaires , Audiometry, Pure-Tone/standards , Audiometry, Speech/standards , Auditory Threshold , Comprehension , Electronic Health Records , Germany , Hearing Loss/diagnosis , Humans , Perceptual Masking , Speech Perception
18.
Ear Hear ; 33(2): 239-49, 2012.
Article in English | MEDLINE | ID: mdl-21918451

ABSTRACT

OBJECTIVES: To determine whether common approaches to setting stimulus parameters influence the depth of fine structure present in the distortion product otoacoustic emission (DPOAE) response. Because the presence of fine structure has been suggested as a possible source of errors, if one of the common parametric approaches results in reduced fine-structure depth, it may be preferred over other approaches. DESIGN: DPOAE responses were recorded in a group of 21 subjects with normal hearing for 1/3-octave intervals surrounding 3 f2s (1, 2, and 4 kHz) at three L2s (30, 45, and 55 dB SPL). For each f2 and L2 combination, L1 and f2/f1 were set according to three commonly used parametric approaches. These included a simple approach, the approach recommended by Kummer et al., and the approach described by Johnson et al. These three approaches primarily differ in the recommended relationship between L1 and L2. For each parametric approach, DPOAE fine structure was evaluated by varying f2 in small steps. Differences in DPOAE level and DPOAE fine-structure depth across f2, L2, and the various stimulus parameters were evaluated using repeated-measures analysis of variance. RESULTS: As expected, significant variations in DPOAE level were observed across the three parametric approaches. For stimulus levels #45 dB SPL, the simple stimuli resulted in lower DPOAE levels than were observed for other approaches. An unexpected finding was that stimulus parameters developed by Johnson et al., which were believed to produce higher DPOAE levels than other approaches, produced the lowest DPOAE levels of the three approaches when f2 = 4 kHz. Significant differences in fine-structure depth were also observed. Greater fine-structure depth was observed with the simple parameters, although this effect was restricted to L2 # 45 dB SPL. When L2 = 55 dB SPL, all three parametric approaches resulted in equivalent fine-structure depth. A significant difference in fine-structure depth across the 3 f2s was also observed. The interval surrounding 2 kHz was associated with greater fine-structure depth than the intervals surrounding 1 and 4 kHz. CONCLUSIONS: The simple stimulus parameters resulted in more fine structure than the other parametric approaches; however, this effect was restricted to L2 # 45 dB SPL. At the moderate stimulus levels used in most clinical applications of DPOAEs (L2 = 55 dB SPL), all three approaches resulted in similar fine-structure depths. These findings suggest that manipulating stimulus parameters, particularly the L1, L2 relationship, is not an effective technique for reducing fine structure, except at the lowest stimulus levels, and that all the common parameters result in equivalent fine structure for moderate stimulus levels. These results also suggest that the stimulus parameters used in future studies of the clinical implications of fine structure may be relatively unimportant, unless stimulus levels #45 dB SPL will be evaluated.


Subject(s)
Acoustic Stimulation/methods , Audiometry, Pure-Tone/methods , Auditory Perception/physiology , Cochlea/physiology , Otoacoustic Emissions, Spontaneous/physiology , Perceptual Distortion/physiology , Acoustic Stimulation/standards , Adult , Audiometry, Pure-Tone/standards , Auditory Threshold/physiology , Ear Canal/physiology , Female , Humans , Male , Middle Aged , Reproducibility of Results , Young Adult
19.
Ear Hear ; 33(1): 19-34, 2012.
Article in English | MEDLINE | ID: mdl-21857517

ABSTRACT

OBJECTIVE: This study compares measurements of ear-canal reflectance (ECR) to other objective measurements of middle ear function including audiometry, umbo velocity (VU), and tympanometry in a population of strictly defined normal-hearing ears. DESIGN: Data were prospectively gathered from 58 ears of 29 normal-hearing subjects, 16 females and 13 males, aged 22 to 64 yr. Subjects met all of the following criteria to be considered as having normal hearing: (1) no history of significant middle ear disease; (2) no history of otologic surgery; (3) normal tympanic membrane on otoscopy; (4) pure-tone audiometric thresholds of 20 dB HL or better for 0.25 to 8 kHz; (5) air-bone gaps no greater than 15 dB at 0.25 kHz and 10 dB for 0.5 to 4 kHz; (6) normal, type-A peaked tympanograms; and (7) all subjects had two "normal" ears (as defined by these criteria). Measurements included pure-tone audiometry for 0.25 to 8 kHz, standard 226 Hz tympanometry, ECR for 0.2 to 6 kHz at 60 dB SPL using the Mimosa Acoustics HearID system, and umbo velocity (VU) for 0.3 to 6 kHz at 70 to 90 dB SPL using the HLV-1000 laser Doppler vibrometer (Polytec Inc). RESULTS: Mean power reflectance (|ECR|) was near 1.0 at 0.2 to 0.3 kHz, decreased to a broad minimum of 0.3 to 0.4 between 1 and 4 kHz, and then sharply increased to almost 0.8 by 6 kHz. The mean pressure reflectance phase angle (∠ECR) plotted on a linear frequency scale showed a group delay of approximately 0.1 msec for 0.2 to 6 kHz. Small significant differences were observed in |ECR| at the lowest frequencies between right and left ears and between males and females at 4 kHz. |ECR| decreased with age but reached significance only at 1 kHz. Our ECR measurements were generally similar to previous published reports. Highly significant negative correlations were found between |ECR| and VU for frequencies below 1 kHz. Significant correlations were also found between the tympanometrically determined peak total compliance and |ECR| and VU at frequencies below 1 kHz. The results suggest that middle ear compliance contributes significantly to the measured power reflectance and umbo velocity at frequencies below 1 kHz but not at higher frequencies. CONCLUSIONS: This study has established a database of objective measurements of middle ear function (ECR, umbo velocity, tympanometry) in a population of strictly defined normal-hearing ears. These data will promote our understanding of normal middle ear function and will serve as a control for comparison to similar measurements made in pathological ears.


Subject(s)
Acoustic Impedance Tests/standards , Ear Canal/physiology , Ear, Middle/physiology , Hearing/physiology , Acoustic Impedance Tests/methods , Adult , Audiometry, Pure-Tone/methods , Audiometry, Pure-Tone/standards , Calibration/standards , Female , Humans , Male , Middle Aged , Reference Values , Sex Characteristics , Young Adult
20.
Ear Hear ; 33(3): 315-29, 2012.
Article in English | MEDLINE | ID: mdl-22436407

ABSTRACT

OBJECTIVES: The purpose of this study was to obtain behavioral hearing thresholds for frequencies between 0.125 and 20 kHz from a large population between 10 and 65 yr old using a clinically feasible calibration method expected to compensate well for variations in the distance between the eardrum and an insert-type sound source. Previous reports of hearing thresholds in the extended high frequencies (>8 kHz) have either used calibration techniques known to be inaccurate or specialized equipment not suitable for clinical use. DESIGN: Hearing thresholds were measured from 352 human subjects between 10 and 65 yr old having clinically normal-hearing thresholds (<20 dB HL) up to 4 kHz. An otoacoustic emission probe fitted with custom sound sources was used, and the stimulus levels individually tailored on the basis of an estimate of the insertion depth of the measurement probe. The calibrated stimulus levels were determined on the basis of measurements made at various depths of insertion in a standard ear simulator. Threshold values were obtained for 21 frequencies between 0.125 and 20 kHz using a modified Békésy technique. Forty-six of the subjects returned for a second measurement months later from the initial evaluation. RESULTS: In agreement with previous reports, hearing thresholds at extended high frequencies were found to be sensitive to age-related changes in auditory function. In contrast with previous reports, no gender differences were found in average hearing thresholds at most evaluated frequencies. Two aging processes, one faster than the other in time scale, seem to influence hearing thresholds in different frequency ranges. The standard deviation (SD) of test-retest threshold difference for all evaluated frequencies was 5 to 10 dB, comparable to that reported in the literature for similar measurement techniques but smaller than that observed for data obtained using the standard clinical procedure. CONCLUSIONS: The depth-compensated ear simulator-based calibration method and the modified Békésy technique allow reliable measurement of hearing thresholds over the entire frequency range of human hearing. Hearing thresholds at the extended high frequencies are sensitive to aging and reveal subtle differences, which are not evident in the frequency range evaluated regularly (≤8 kHz). Previously reported gender-related differences in hearing thresholds may be related to ear-canal acoustics and the calibration procedure and not because of differences in hearing sensitivity.


Subject(s)
Audiometry, Pure-Tone/methods , Auditory Threshold/physiology , Otoacoustic Emissions, Spontaneous/physiology , Pitch Perception/physiology , Presbycusis/diagnosis , Presbycusis/physiopathology , Adolescent , Adult , Aged , Aging/physiology , Audiometry, Pure-Tone/standards , Behavior , Calibration/standards , Child , Female , Hearing/physiology , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Sound Localization/physiology , Young Adult
SELECTION OF CITATIONS