Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.429
Filter
Add more filters

Publication year range
1.
Reprod Biomed Online ; 48(4): 103733, 2024 04.
Article in English | MEDLINE | ID: mdl-38401251

ABSTRACT

RESEARCH QUESTION: How do clinical rectovaginal examination and transvaginal ultrasound examination perform in the diagnosis of parametrial infiltration in patients with endometriosis? DESIGN: This was a multicentre prospective observational study. Patients with suspected deep endometriosis at clinical examination and/or at ultrasound evaluation and scheduled for surgery were included. Following multicentre multidisciplinary meetings, consensus was obtained on terms and methodology to define the parametrium at pelvic anatomy, ultrasound and surgery. Sensitivity, specificity, accuracy, and positive and negative likelihood ratios were calculated for clinical and ultrasound examinations with respect to surgery. RESULTS: In total, 195 women were selected for the present study and 164 were included in the analysis. Ultrasound examination had good to high specificity (>80%) for all parameters, except the left lateral parametrium (78.8%). The sensitivity of ultrasound examination was good to high for fixity of the right and left ovaries, uterosacral ligaments, retrocervix and rectovaginal space; and low for the anterior and lateral parametria, vagina, bladder and bowel. Clinical examination had good to high specificity for fixity of the left ovary, anterior parametrium, right uterosacral ligament, retrocervix and vagina; and low specificity for fixity of the right ovary, lateral parametrium, left uterosacral ligament and rectovaginal space. The sensitivity of clinical examination was good for the uterosacral ligaments and rectovaginal space, and low for the remaining parameters. CONCLUSION: Ultrasound examination provided good specificity for all the parameters, but sensitivity was low for the anterior and lateral parametria. Clinical examination provided good specificity for the anterior and posterior parametria, but sensitivity was low for the anterior and lateral parametria. Further prospective studies are needed to validate this methodology and confirm the results.


Subject(s)
Endometriosis , Female , Humans , Endometriosis/surgery , Peritoneum , Prospective Studies , Sensitivity and Specificity , Ultrasonography/methods , Vagina/diagnostic imaging
2.
BJOG ; 131(3): 267-277, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37522240

ABSTRACT

OBJECTIVE: To identify vaginal morphology and position factors associated with prolapse recurrence following vaginal surgery. DESIGN: Secondary analysis of magnetic resonance images (MRI) of the Defining Mechanisms of Anterior Vaginal Wall Descent cross-sectional study. SETTING: Eight clinical sites in the US Pelvic Floor Disorders Network. POPULATION OR SAMPLE: Women who underwent vaginal mesh hysteropexy (hysteropexy) with sacrospinous fixation or vaginal hysterectomy with uterosacral ligament suspension (hysterectomy) for uterovaginal prolapse between April 2013 and February 2015. METHODS: The MRI (rest, strain) obtained 30-42 months after surgery, or earlier for participants with recurrence who desired reoperation before 30 months, were analysed. MRI-based prolapse recurrence was defined as prolapse beyond the hymen at strain on MRI. Vaginal segmentations (at rest) were used to create three-dimensional models placed in a morphometry algorithm to quantify and compare vaginal morphology (angulation, dimensions) and position. MAIN OUTCOME MEASURES: Vaginal angulation (upper, lower and upper-lower vaginal angles in the sagittal and coronal plane), dimensions (length, maximum transverse width, surface area, volume) and position (apex, mid-vagina) at rest. RESULTS: Of the 82 women analysed, 12/41 (29%) in the hysteropexy group and 22/41 (54%) in the hysterectomy group had prolapse recurrence. After hysteropexy, women with recurrence had a more laterally deviated upper vagina (p = 0.02) at rest than women with successful surgery. After hysterectomy, women with recurrence had a more inferiorly (lower) positioned vaginal apex (p = 0.01) and mid-vagina (p = 0.01) at rest than women with successful surgery. CONCLUSIONS: Vaginal angulation and position were associated with prolapse recurrence and suggestive of vaginal support mechanisms related to surgical technique and potential unaddressed anatomical defects. Future prospective studies in women before and after prolapse surgery may distinguish these two factors.


Subject(s)
Pelvic Organ Prolapse , Uterine Prolapse , Female , Humans , Prospective Studies , Cross-Sectional Studies , Treatment Outcome , Gynecologic Surgical Procedures/methods , Vagina/diagnostic imaging , Vagina/surgery , Hysterectomy, Vaginal , Uterine Prolapse/surgery , Pelvic Organ Prolapse/surgery
3.
Ultrasound Obstet Gynecol ; 63(2): 263-270, 2024 02.
Article in English | MEDLINE | ID: mdl-37725753

ABSTRACT

OBJECTIVE: To determine the diagnostic test accuracy of transvaginal ultrasound (TVS) using a standardized technique for the diagnosis of deep endometriosis (DE) of the uterosacral ligaments (USLs) and adjacent torus uterinus (TU). METHODS: This was a prospective diagnostic test accuracy study conducted at the McMaster University Medical Center Tertiary Endometriosis Clinic, Hamilton, ON, Canada. Consecutive participants were enrolled if they successfully underwent TVS and surgery by our team from 10 August 2020 to 31 October 2021. The index test was TVS using a standardized posterior approach performed and interpreted by an expert sonologist. The reference standard included direct surgical visualization on laparoscopy by the same person who performed and interpreted the ultrasound scans. Accuracy, sensitivity, specificity, positive and negative predictive values (PPV and NPV) and positive and negative likelihood ratios were calculated for the TVS posterior approach for each location using the reference standard. RESULTS: There were 54 consecutive participants included upon completion of laparoscopy and histological assessment. The prevalence of DE for the left USL, right USL and TU was 42.6%, 22.2% and 14.8%, respectively. Based on surgical visualization as the reference standard, TVS demonstrated an accuracy of 92.6% (95% CI, 82.1-97.9%), sensitivity of 82.6% (95% CI, 61.2-95.1%), specificity of 100% (95% CI, 88.8-100%), PPV of 100% and NPV of 88.6% (95% CI, 76.1-95.0%) for diagnosing DE in the left USL. For DE of the right USL, TVS demonstrated an accuracy of 94.4% (95% CI, 84.6-98.8%), sensitivity of 75.0% (95% CI, 42.8-94.5%), specificity of 100% (95% CI, 91.6-100%), PPV of 100% and NPV of 93.3% (95% CI, 84.0-97.4%). For DE of the TU, TVS demonstrated an accuracy of 100% (95% CI, 93.4-100%), sensitivity of 100% (95% CI, 63.1-100%), specificity of 100% (95% CI, 92.3-100%), PPV of 100% and NPV of 100%. CONCLUSIONS: We observed high diagnostic test accuracy of the evaluated standardized TVS technique for assessing DE of the USLs and TU. Further studies evaluating this technique should be performed, particularly with less experienced observers, before considering this technique as the standard approach. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Subject(s)
Endometriosis , Vagina , Female , Pregnancy , Humans , Vagina/diagnostic imaging , Vagina/pathology , Endometriosis/diagnostic imaging , Endometriosis/surgery , Sensitivity and Specificity , Prospective Studies , Ultrasonography/methods , Ligaments/diagnostic imaging , Ligaments/pathology , Diagnostic Tests, Routine
4.
Clin Radiol ; 79(8): 618-627, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38797608

ABSTRACT

AIM: We aimed to compare the diagnostic performance of transvaginal sonography (TVS) versus magnetic resonance imaging (MRI) in identifying deep infiltrating endometriosis (DIE) in the rectovaginal septum (RVS) of affected patients. MATERIALS AND METHODS: An extensive search was conducted in the PubMed, Embase databases to identify available publications up to November 2023. Studies evaluating the diagnostic perfor-mance of TVS and MRI for DIE in patients with rectovaginal septum involvement were all included. Sensitivity and specificity analyses employed the DerSi-monian and Laird method, complemented by the Freeman-Tukey double arc-sine trans-formation. Additionally, the study quality was rigorously evaluated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) method. RESULTS: The meta-analysis encompassed 8 articles with a total of 721 patients. It revealed that the overall sensitivity of TVS was 0.51 (95% CI: 0.31-0.72), contrasted with 0.74 (95% CI: 0.66-0.82) for MRI. This finding suggests a higher sensitivity of MRI compared to TVS (P=0.04). Conversely, the overall specificity was 0.97 (95%CI: 0.94-1.00) for TVS and 0.93 (95% CI: 0.84-0.99) for MRI, indicating a comparable level of specificity between the two modalities (P=0.22). CONCLUSION: Our meta-analysis reveals that MRI exhibits higher sensitivity and comparable specificity to TVS in patients with DIE of the RVS. However, the limited number of articles included may affect the evidence of these results. Therefore, further d number of articles included may affect the evidence of these results. Therefore, further research with larger sample sizes and prospective designs is essential to validate these findings.


Subject(s)
Endometriosis , Magnetic Resonance Imaging , Rectum , Ultrasonography , Vagina , Humans , Endometriosis/diagnostic imaging , Female , Magnetic Resonance Imaging/methods , Ultrasonography/methods , Vagina/diagnostic imaging , Rectum/diagnostic imaging , Sensitivity and Specificity
5.
Med Sci Monit ; 30: e945458, 2024 Oct 09.
Article in English | MEDLINE | ID: mdl-39431649

ABSTRACT

BACKGROUND Assessment of labor progress via digital vaginal examination is subjective, while intrapartum transperineal ultrasonography is deemed more objective and effective. The angle of descent (AoD) is a reliable intrapartum transperineal ultrasound parameter with minimal inter-observer and intra-observer errors. This study compared intrapartum transperineal ultrasonography with digital vaginal examination in evaluating the angle of descent for vaginal delivery selection in 70 women. MATERIAL AND METHODS This cross-sectional study was conducted at Dr. Mohammad Hoesin Hospital Palembang in Indonesia, using a consecutive sampling method to measure AoD of 70 patients at admission and every 2 h during labor progression. Patients were monitored until childbirth, and outcomes of successful vaginal or cesarean delivery were reported. A diagnostic test determined the optimal AoD for predicting successful vaginal delivery and its predictive value. RESULTS The study included 70 patients with a mean age of 28.29±6.09 years and a body mass index of 30.59±3.49 kg/m². Among them, 29 (41%) had successful vaginal deliveries. Adequate contraction frequency at admission was strongly associated with successful vaginal delivery (P<0.001). The optimal AoD for predicting successful vaginal delivery was 94.5°, with an area under the curve of 0.567 (95% CI 0.425-0.710), sensitivity of 84.2%, specificity of 45.7%, and accuracy of 54.3%. CONCLUSIONS Intrapartum transperineal ultrasonography for measuring AoD can be a valuable adjunct in labor management. Further investigations are needed to validate the optimal AoD in Indonesian pregnant women.


Subject(s)
Delivery, Obstetric , Labor, Obstetric , Ultrasonography , Humans , Female , Pregnancy , Adult , Delivery, Obstetric/methods , Cross-Sectional Studies , Ultrasonography/methods , Indonesia , Perineum/diagnostic imaging , Ultrasonography, Prenatal/methods , Vagina/diagnostic imaging , Cesarean Section , Young Adult , Parturition
6.
J Ultrasound Med ; 43(5): 913-921, 2024 May.
Article in English | MEDLINE | ID: mdl-38284137

ABSTRACT

OBJECTIVES: The changes of the extracellular matrix of the connective tissue have significantly contributed to the incidence of pelvic organ prolapse (POP). It seems reasonable that sonoelastography could be a useful tool to evaluate the elasticity of pelvic floor tissue in patients with POP and compare it to those without POP. The main aim of this pilot study was to determine if there are differences in the elasticity of the levator ani muscle (LAM) and vaginal tissue between patients with and without POP. METHODS: Prospective observation study, including 60 patients (30 with POP and 30 without POP). Sonoelastography was performed to evaluate the elasticity (in kilopascals, kPa) of the following regions of interest: vagina at the level of middle third of the urethra; vagina at the level of the bladder trigone; vagina in the anterior and posterior fornix; vagina at the level of middle third of the anorectal canal; posterior third of the LAM. RESULTS: A total of 60 patients completed the study (30 with POP, 30 without POP). In the POP group, 18/30 (60%) had an anterior vaginal wall prolapse, 3/30 (10%) a uterine prolapse, 15/30 (50%) a rectocele, and 6/30 (20%) a enterocele. Patients with POP had higher elasticity in all anatomical study areas, with statistically significant differences in the anterior fornix (13.6 vs 11.2 kPa; P: .012). A multiple regression (controlling age, menopausal stage, and parity) allowed to detect statistically significant differences in the elasticity of the middle third of the urethra (P: .03) and the middle third of the anorectal canal (P: .019). CONCLUSION: It is possible to evaluate the elasticity of the LAM and vaginal tissue using sonoelastography, detecting a higher elasticity in patients with POP than in those without POP.


Subject(s)
Elasticity Imaging Techniques , Pelvic Organ Prolapse , Uterine Prolapse , Female , Humans , Elasticity , Pelvic Floor/diagnostic imaging , Pelvic Organ Prolapse/diagnostic imaging , Pilot Projects , Prospective Studies , Vagina/diagnostic imaging
7.
Gynecol Obstet Invest ; 89(2): 111-119, 2024.
Article in English | MEDLINE | ID: mdl-38377973

ABSTRACT

OBJECTIVE: The aim of the study was to evaluate the diagnostic accuracy for parametria endometriosis (PE) of transvaginal sonography (TVS) performed following a systematic approach for the assessment of the lateral parametria. DESIGN: A diagnostic accuracy study was employed based on a prospective observational design. PARTICIPANTS: All consecutive patients who underwent laparoscopic surgery for endometriosis between January 2016 and December 2020 were considered. SETTING: The study was conducted at endometriosis referral hospitals. METHODS: We prospectively collected clinical, imaging, and surgical data of all consecutive patients who underwent laparoscopic surgery for endometriosis between January 2016 and December 2020. A standardized technique with a systematic approach for the assessment of the lateral parametria following specific anatomic landmarks was used for the TVS. The diagnostic accuracy for PE in TVS was assessed using the intraoperative and pathologic diagnosis of PE as the gold standard. RESULTS: In 476 patients who underwent surgery, PE was identified in 114 out of 476 patients (23.95%): 91 left and 54 right PE out of 476 surgical procedures were identified (19.12% vs. 11.34%; p = 0.001); bilateral involvement in 27.19% (31/114 patients) cases. The sensitivity of TVS for PE was 90.74% (79.70-96.92%, 95% CI) for the right side and 87.91% (79.40-93.81%, 95% CI) for the left side. The specificity was almost identical for both sides (98.58% vs. 98.18%). For the right parametrium, the positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 63.82 (28.70-141.90, 95% CI) and 0.09 (0.04-0.22, 95% CI), respectively. On the left parametrium, the PLR and NLR were 48.35 (23.12-101.4, 95% CI) and 0.12 (0.07-0.21, 95% CI), respectively. The diagnostic accuracy for right and left PE was 97.69% (95.90-98.84%, 95% CI) and 96.22% (94.04-97.74%, 95% CI), respectively. LIMITATIONS: The principal limit is the high dependence of TVS on the operator experience. Therefore, although a standardized approach following precise definitions of anatomical landmarks was used, we cannot conclude that the observed accuracy of TVS for PE is the same for all sonographers. In this regard, the learning curve was not assessed. In the case of negative TVS for parametrial involvement with an absent intraoperative suspect, a complete dissection of the parametrium was not performed to avoid surgical complications; therefore, cases of minor PE may be missed, underestimating false negatives. CONCLUSIONS: TVS performed following a systematic approach for assessing the lateral parametria seems to have good diagnostic accuracy for PE with large changes in the posttest probability of parametrial involvement based on the TVS evaluation. Considering the clinical and surgical implications of PE, further studies implementing a standardized approach for assessing the parametrium by TVS are recommended to confirm our observations and implement a standardized protocol in clinical practice.


Subject(s)
Endometriosis , Laparoscopy , Female , Humans , Endometriosis/diagnostic imaging , Endometriosis/surgery , Ultrasonography/methods , Sensitivity and Specificity , Vagina/diagnostic imaging , Vagina/surgery , Vagina/pathology
8.
J Obstet Gynaecol Res ; 50(1): 47-54, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37916525

ABSTRACT

AIM: This study aimed to evaluate the effect of preinduction cervical length (CL) measurement by transvaginal (TV), transperineal (TP), and transabdominal (TA) ultrasonography (USG) on the time of delivery and to compare these three sonographic methods in terms of superiority over one another. METHODS: This study included TV, TP, and TA CL measurements in pregnant women who were planned to undergo induction of labor at 37 weeks' gestation or later. The correlations between the said three methods and BISHOP scores were evaluated. These three methods were compared in terms of superiority in predicting the time of delivery. RESULTS: Pregnant women at 37-42 weeks' gestation undergoing labor induction were included, and all three methods were used for CL measurements. Three methods were correlated with each other (p < 0.001) and with BISHOP scores (p < 0.001). CONCLUSION: The correlation between all three methods and BISHOP scores indicates that TP and TA USG can be used instead of TV USG. On the other hand, while TA USG did not give a clear result in the accurate estimation of vaginal delivery time, TP, and TV USG gave both accurate and close results. When all these data are evaluated, it is concluded that TPU can be used safely instead of TVU, especially in patients receiving induction.


Subject(s)
Cervical Length Measurement , Cervix Uteri , Pregnancy , Female , Humans , Cervical Length Measurement/methods , Cervix Uteri/diagnostic imaging , Delivery, Obstetric/methods , Vagina/diagnostic imaging , Gestational Age , Labor, Induced , Predictive Value of Tests
9.
Ultraschall Med ; 45(1): 61-68, 2024 Feb.
Article in English | MEDLINE | ID: mdl-36781162

ABSTRACT

OBJECTIVES: To test the accuracy of TVS applying the IDEA approach for suspected rectosigmoid DE and to determine the frequency of other pelvic diseases mimicking DE in patients undergoing surgery. MATERIALS UND METHODS: Prospective single center observational study including consecutive women undergoing TVS for clinically suspected rectosigmoid DE followed by conservative or surgical therapy. TVS findings were compared with those obtained by laparoscopy and confirmed histologically. RESULTS: Of the 671 included patients, 128 women opted for medical therapy, and 6 patients decided for surgery but did not give consent to participate in the study. 537 women were enrolled in the final analysis. 279 (52 %) exhibited surgically confirmed rectosigmoid DE. The sensitivity and specificity, positive and negative predictive value (PPV, NPV), positive and negative likelihood ratio (LR+/-) and accuracy of TVS for diagnosing DE in the rectosigmoid were 93.5 %, 94.6 %, 94.9 %, 93.1 %, 17.24, 0.07, 94.04 %. 12 women who were clinically suspected for DE and mimicked sonographic signs fulfilling the IDEA criteria did exhibit other pathologies. Diagnoses were as follows: vaginal Gartner duct cyst (3/291;1.0 %), anorectal abscess (3/291; 1.0 %), rectal cancer (2/291;0.7 %), hydrosalpinx (2/291;0.7 %), metastatic endometrial cancer (1/291;0.35 %) and Crohn's disease (1/291;0.35 %). CONCLUSION: TVS for diagnosing colorectal DE applying the IDEA criteria is highly accurate for presurgical diagnosis. However, additional pelvic pathologies are encountered in 4-5 % of women attending for suspected rectosigmoid DE. These need to be taken into account when investigating patients for suspected DE.


Subject(s)
Antineoplastic Combined Chemotherapy Protocols , Endometriosis , Female , Humans , Cytarabine , Dexamethasone , Endometriosis/diagnostic imaging , Endometriosis/surgery , Etoposide , Ifosfamide , Prospective Studies , Sensitivity and Specificity , Ultrasonography/methods , Vagina/diagnostic imaging
10.
Ultraschall Med ; 45(4): 367-388, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38788738

ABSTRACT

We present a new systematic, comprehensive, checklist-based sonographic assessment of endometriosis in the female true pelvis. Emphasis is placed on practical skills teaching. The newly introduced White Sliding Line (WSL) is the core structure. The WSL separates five compartments (anterior, central, posterior, and lateral right and left) containing dedicated endometriosis signs of mobility and morphology to be checked. This approach relies on the 2016 IDEA Consensus and further developments. It directly connects to the 2021 #ENZIAN Classification Standard. In practice, evaluation follows the proposed checklist in all compartments, judging first sliding mobility between organs and structures in a highly dynamic investigation. A rigorous search for deep endometriosis (DE) is then performed. We treat adhesions due to their great clinical importance and possible, reliable diagnosis by TVS as the fifth endometriosis unit, next to endometrioma, DE, adenomyosis, and superficial endometriosis. Including superficial (peritoneal) endometriosis is a future goal.


Subject(s)
Endometriosis , Ultrasonography , Endometriosis/diagnostic imaging , Female , Humans , Ultrasonography/methods , Societies, Medical , Switzerland , Checklist , Vagina/diagnostic imaging , Sensitivity and Specificity , Tissue Adhesions/diagnostic imaging
11.
J Obstet Gynaecol ; 44(1): 2311664, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38348799

ABSTRACT

INTRODUCTION: The diagnosis of endometriomas in patients with endometriosis is of primary importance because it influences the management and prognosis of infertility and pain. Imaging techniques are evolving constantly. This study aimed to systematically assess the diagnostic accuracy of transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI) in detecting endometrioma using the surgical visualisation of lesions with or without histopathological confirmation as reference standards in patients of reproductive age with suspected endometriosis. METHODS: PubMed, Embase, Web of Science, Cumulative Index to Nursing and Allied Health Literature and ClinicalTrials.gov databases were searched from their inception to 12 October 2022, using a manual search for additional articles. Two authors independently performed title, abstract and full-text screening of the identified records, extracted study details and quantitative data and assessed the quality of the studies using the 'Quality Assessment of Diagnostic Accuracy Study 2' tool. Bivariate random-effects models were used to determine the pooled sensitivity and specificity, compare the two imaging modalities and evaluate the sources of heterogeneity. RESULTS: Sixteen prospective studies (10 assessing TVUS, 4 assessing MRI and 2 assessing both TVUS and MRI) were included, representing 1976 participants. Pooled TVUS and MRI sensitivities for endometrioma were 0.89 (95% confidence interval 'CI', 0.86-0.92) and 0.94 (95% CI, 0.74-0.99), respectively (indirect comparison p-value of 0.47). Pooled TVUS and MRI specificities for endometrioma were 0.95 (95% CI, 0.92-0.97) and 0.94 (95% CI, 0.89-0.97), respectively (indirect comparison p-value of 0.51). These studies had a high or unclear risk of bias. A direct comparison (all participants undergoing TVUS and MRI) of the modalities was available in only two studies. CONCLUSION: TVUS and MRI have high accuracy for diagnosing endometriomas; however, high-quality studies comparing the two modalities are lacking.


The diagnosis of endometriomas in patients with endometriosis impacts infertility and pain management. We performed a systematic review and meta-analysis to assess the accuracy of transvaginal ultrasound and magnetic resonance imaging for the diagnosis of endometrioma in patients of reproductive age with suspected endometriosis, and to compare the accuracy of the two imaging modalities. Five databases (PubMed, Embase, Web of Science, Cumulative Index to Nursing and Allied Health Literature and ClinicalTrials.gov databases) were searched. Sixteen prospective studies were included, representing 1976 participants. We found high accuracy of transvaginal ultrasound and magnetic resonance imaging for diagnosing endometriomas. There was no statistically significant difference in diagnostic accuracy between the two modalities. However, high-quality studies comparing the two modalities in the same population are lacking.


Subject(s)
Endometriosis , Magnetic Resonance Imaging , Ultrasonography , Adult , Female , Humans , Endometriosis/diagnostic imaging , Magnetic Resonance Imaging/methods , Sensitivity and Specificity , Ultrasonography/methods , Vagina/diagnostic imaging
12.
Medicina (Kaunas) ; 60(3)2024 Feb 22.
Article in English | MEDLINE | ID: mdl-38541095

ABSTRACT

Background and Objectives: A consensus regarding the optimal sonographic technique for measuring vaginal wall thickness (VWT) is still absent in the literature. This study aims to validate a new method for measuring VWT using a biplanar transvaginal ultrasound probe and assess both its intra-operator and inter-operator reproducibility. Material and Methods: This prospective study included patients with genitourinary syndrome of menopause-related symptoms. Women were scanned using a BK Medical Flex Focus 400 with the 65 × 5.5 mm linear longitudinal transducer of an endovaginal biplanar probe (BK Medical probe 8848, BK Ultrasound, Peabody, MA, USA). Vaginal wall thickness (VWT) measurements were acquired from the anterior and posterior vaginal wall at three levels. Results: An inter-observer analysis revealed good consistency between operators at every anatomical site, and the intra-class coefficient ranged from 0.931 to 0.987, indicating high reliability. An intra-observer analysis demonstrated robust consistency in vaginal wall thickness measurements, with an intra-class coefficient exceeding 0.9 for all anatomical sites. Conclusions: The measurement of vaginal wall thickness performed by transvaginal biplanar ultrasound was easy and demonstrated good intra- and inter-operator reliability.


Subject(s)
Vagina , Humans , Female , Reproducibility of Results , Prospective Studies , Observer Variation , Ultrasonography , Vagina/diagnostic imaging
13.
Medicina (Kaunas) ; 60(4)2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38674171

ABSTRACT

Background and Objectives: Neoplasms of the vagina are rare and account for 1-2% of all tumors of the female reproductive system. Primary neoplasms of the vagina are most often carcinomas originating from squamous or glandular epithelium. Of the primary glandular tumors, clear cell, endometrioid, and serous adenocarcinomas are the most common types, while mucinous and mesonephric types are very rare. Mucinous adenocarcinoma is histologically subclassified into endocervical and intestinal types. We add to the existing literature another case of an extremely rare gynecological neoplasm-primary vaginal mucinous adenocarcinoma (PVMAC) intestinal type associated with vaginal villous adenoma with high-grade dysplasia. We discuss the clinical, radiological and morphological features of this rare entity. Materials and Methods: We report a case of a 59-year-old woman with PVMAC intestinal type associated with vaginal villous adenoma with high-grade dysplasia. The patient was evaluated with a gynecological exam, and biopsy, curettage and tumor excision were performed. The positron emission tomography-computed tomography (PET/CT) scan, at the level of the pelvis, supported the primary location of the disease. Histological and immunohistochemical methods were applied. Results: The gynecological examination of the vagina revealed an exophytic polypoid mass with a diameter of 3 cm, located on the posterior wall, in the area of introitus vaginae. The PET/CT scan revealed a hypermetabolic malignant formation involving the vagina and anal canal, without evidence of pelvic and inguinal lymphadenopathy, and also, it excluded disease at sites other than the vagina. The histological and immunohistochemical investigations, as well as the clinical and radiological data, lent support to the diagnosis "primary vaginal mucinous adenocarcinoma intestinal type". Conclusions: PVMAC intestinal type is a rare gynecological pathology, which presents a serious challenge for oncogynecologists, radiologists and pathologists.


Subject(s)
Adenocarcinoma, Mucinous , Vaginal Neoplasms , Humans , Female , Middle Aged , Adenocarcinoma, Mucinous/pathology , Adenocarcinoma, Mucinous/diagnostic imaging , Adenocarcinoma, Mucinous/diagnosis , Adenocarcinoma, Mucinous/surgery , Vaginal Neoplasms/pathology , Vaginal Neoplasms/diagnostic imaging , Vaginal Neoplasms/surgery , Vaginal Neoplasms/diagnosis , Positron Emission Tomography Computed Tomography/methods , Vagina/pathology , Vagina/diagnostic imaging
14.
Med J Malaysia ; 79(Suppl 4): 83-86, 2024 08.
Article in English | MEDLINE | ID: mdl-39215421

ABSTRACT

Obstructed hemivagina and ipsilateral renal anomaly (OHVIRA) is a rare congenital malformation of the female urogenital tract characterized by a triad of uterine didelphys, obstructed hemivagina, and ipsilateral renal anomaly. It was formerly known as Herlyn Werner Wunderlich Syndrome (HWWS). The syndrome usually presents with cyclic pelvic pain following menarche. Endometriosis is a prevalent complication. Magnetic resonance imaging (MRI) helps in diagnosing OHVIRA syndrome and endometriosis due to its high contrast resolution and objectivity. We reported a 13- year-old girl who was evaluated for cyclic pelvic pain after her menarche at 12 years of age. Magnetic resonance imaging (MRI) revealed two separate uterine cavities, services and vaginae, indicating didelphys. The left uterine cavity is filled with fluid, and the left hemivagina is dilated and filled with hyperintense and hypointense fluid on T1 and T2, respectively, indicating blood products. Left hemivagina dilatation implicated the presence of an obstructing vaginal septum. A single left adnexal cyst lesion with blood products was suggestive of an endometriotic cyst. Additionally, the left kidney was absent. A uterine didelphys with left hemivagina obstruction, hematometra, hematocolpos, and the ipsilateral ovarian endometriotic cyst was diagnosed. A final diagnosis of OHVIRA syndrome or HWWS was made, considering that she had no left kidney.MRI is a suitable diagnostic tool for precise anatomical delineation of the uterus, cervix, and vagina in uterovaginal disorders such as OHVIRA syndrome. MRI can also properly evaluate endometriosis and adhesion.


Subject(s)
Endometriosis , Kidney , Magnetic Resonance Imaging , Vagina , Humans , Female , Endometriosis/complications , Endometriosis/diagnostic imaging , Endometriosis/diagnosis , Adolescent , Kidney/abnormalities , Kidney/diagnostic imaging , Vagina/abnormalities , Vagina/diagnostic imaging , Syndrome , Urogenital Abnormalities/diagnostic imaging , Urogenital Abnormalities/complications , Urogenital Abnormalities/diagnosis
15.
Int J Hyperthermia ; 40(1): 2211276, 2023.
Article in English | MEDLINE | ID: mdl-37357319

ABSTRACT

OBJECTIVES: To investigate changes in vaginal microecology in women with high-risk human papillomavirus (HR-HPV) infection after focused ultrasound (FU) treatment. MATERIALS AND METHODS: We collected vaginal secretions at the time of admission and 3 months after FU treatment from 169 women who received FU treatment for cervical HR-HPV infection between July 2020 and September 2022. Among them, there were 101 patients with cute vaginitis, we also collected their vaginal secretions after one week of drug treatment. These samples were evaluated for vaginal microecology and HPV-DNA examination. RESULTS: Of the 169 patients, 101 (59.7%) suffered from acute vaginitis at the time of admission. After one week of targeted antibiotics drug treatment, there were no pathogens or pus cells on the field of microscopic vision, but there was no significant difference(p > 0.05) in the diversity and density of vaginal flora, the proportion and function of Lactobacillus (H2O2 negative rate) between one week after treatment and at the time of admission. At the time of admission of the 169 patients, the normal flora rate was 40.3%, which increased to 93.5% three months after FU treatment. The differences in vaginal secretion parameters at the time of admission and 3 months after FU treatment were as follows: H2O2 negative rate (37.3% vs. 3.6%), leukocyte esterase positive rate (54.4% vs. 5.9%), sialidase positive rate (38.5% vs. 4.1%), bacterial vaginitis positive rate (55% vs. 4.7%), fungal vaginitis positive rate (44.4% vs. 5.9%), and trichomonal vaginitis positive rate (7.1% vs. 0). The difference was statistically significant (p < 0.01). The pH value and Nagent score at the time of admission were significantly higher than those three months after FU. Three months after FU, the positive rate of HPV was 5.8% in the group of patients with normal vaginal microecology at the time of admission and post-FU; it was 6.7% in the group of patients with abnormal vaginal microecology at the time of admission and normal vaginal microecology post-FU; and it was 100% in the group patients with abnormal vaginal microecology at the time of admission and post-FU. A significant difference was observed among the three groups (p < 0.01). CONCLUSION: FU is an effective treatment for patients with cervical HR-HPV infection. FU does not interfere with the vaginal microecology of HR-HPV positive patients with normal vaginal microecology.FU followed by antibiotic drug therapy for pathogens is beneficial to restore the function of Lactobacillus vaginalis in HR-HPV positive patients with acute vaginitis,so as to improve the vaginal microecology of HR-HPV positive patients with abnormal vaginal microecology.


Subject(s)
Papillomavirus Infections , Uterine Cervical Neoplasms , Vaginitis , Humans , Female , Papillomavirus Infections/drug therapy , Hydrogen Peroxide , Papillomaviridae/genetics , Vagina/diagnostic imaging , Vaginitis/drug therapy , Vaginitis/microbiology
16.
Clin Radiol ; 78(3): 168-174, 2023 03.
Article in English | MEDLINE | ID: mdl-36273955

ABSTRACT

AIM: To evaluate the presentations of Müllerian duct anomalies (MDAs) associated with unilateral renal agenesis (URA) on magnetic resonance imaging (MRI). MATERIALS AND METHODS: From 2014 to 2021, 92 patients with MDAs coexisting with URA who had undergone MRI were reviewed, and imaging patterns were analysed. RESULTS: Based on the different imaging patterns, there were 74 cases of Herlyn-Werner-Wunderlich (HWW) syndrome (80.4%), nine cases of unicornuate uterus (10.9%), and nine cases of Mayer-Rokitansky-Kuster-Hauser (MRKH) syndrome (8.7%). In HWW syndrome, URA was ipsilateral to the vaginal or cervical obstruction. All the nine cases of unicornuate uterus were obstructive, and the most common subtype was unicornuate uterus with a non-communicating functioning rudimentary horn. The other two cases of unicornuate uterus with no rudimentary horn were obstructed due to cervical os obliteration, one of which was complicated with contralateral absent ovary. URA was contralateral to the unicornuate uterus in all cases. In MRKH syndrome, seven patients had bilateral rudiments and ovaries, all of which were unilaterally or bilaterally located above the pelvic brim, and URA was ipsilateral to the ectopic ovary in all cases. The other two patients had unilateral absent rudiment, ovary, and ipsilateral URA. CONCLUSIONS: MRI presentations of URA-associated MDAs are diverse, with HWW syndrome being the most common form, followed by different patterns of unicornuate uterus and MRKH syndrome. An ectopic or absent ovary might be associated with URA in MRKH syndrome and unicornuate uterus.


Subject(s)
Abnormalities, Multiple , Solitary Kidney , Female , Humans , Mullerian Ducts/diagnostic imaging , Mullerian Ducts/abnormalities , Retrospective Studies , Abnormalities, Multiple/diagnostic imaging , Uterus/diagnostic imaging , Magnetic Resonance Imaging/methods , Vagina/diagnostic imaging
17.
Int Urogynecol J ; 34(8): 1923-1931, 2023 08.
Article in English | MEDLINE | ID: mdl-36802015

ABSTRACT

INTRODUCTION AND HYPOTHESIS: Our objective was to develop a standardized measurement system to evaluate structural support site failures among women with anterior vaginal wall-predominant prolapse according to increasing prolapse size using stress three-dimensional (3D) magnetic resonance imaging (MRI). METHODS: Ninety-one women with anterior vaginal wall-predominant prolapse and uterus in situ who had undergone research stress 3D MRI were included for analysis. The vaginal wall length and width, apex and paravaginal locations, urogenital hiatus diameter, and prolapse size were measured at maximal Valsalva on MRI. Subject measurements were compared to established measurements in 30 normal controls without prolapse using a standardized z-score measurement system. A z-score greater than 1.28, or the 90th percentile in controls, was considered abnormal. The frequency and severity of structural support site failure was analyzed based on tertiles of prolapse size. RESULTS: Substantial variability in support site failure pattern and severity was identified, even between women with the same stage and similar size prolapse. Overall, the most common failed support sites were straining hiatal diameter (91%) and paravaginal location (92%), followed by apical location (82%). Impairment severity z-score was highest for hiatal diameter (3.56) and lowest for vaginal width (1.40). An increase in impairment severity z-score was observed with increasing prolapse size among all support sites across all three prolapse size tertiles (p < 0.01 for all). CONCLUSIONS: We identified substantial variation in support site failure patterns among women with different degrees of anterior vaginal wall prolapse using a novel standardized framework that quantifies the number, severity, and location of structural support site failures.


Subject(s)
Pelvic Organ Prolapse , Uterine Prolapse , Female , Humans , Vagina/diagnostic imaging , Uterine Prolapse/diagnostic imaging , Uterus , Magnetic Resonance Imaging , Pelvic Floor , Pelvic Organ Prolapse/diagnostic imaging
18.
Int Urogynecol J ; 34(9): 2293-2300, 2023 09.
Article in English | MEDLINE | ID: mdl-37119269

ABSTRACT

INTRODUCTION AND HYPOTHESIS: The objective was to compare the location and motion of pessaries between women with pelvic organ prolapse (POP) with a successful (fitting) and unsuccessful (non-fitting) pessary treatment on dynamic magnetic resonance imaging (dMRI). METHODS: A cross-sectional exploratory study of 15 women who underwent a mid-sagittal dMRI of the pelvic floor at rest, during contraction and during Valsalva with three different types of pessaries. The coordinates of the pessaries cross section, inferior pubic point (IPP) and sacrococcygeal junction (SCJ) were obtained and the location (position, orientation) and the motion (translation and rotation) were calculated. Differences between the groups and between the pessaries within the groups were compared. RESULTS: Nine women with a fitting pessary and 6 women with a non-fitting pessary were selected. In the non-fitting group, the pessaries were positioned more caudally and rotated more in clockwise direction and descended more, but not significantly, during Valsalva compared with the fitting group. The Falk pessary was positioned more anteriorly in the fitting group and more cranially in the non-fitting group compared with the ring and ring with support pessary. CONCLUSIONS: A non-fitting pessary was positioned more caudally at rest; on Valsalva, it rotated more clockwise and moved more caudally, suggesting that the dynamic characteristics of the pessary might play an important role in its effectiveness. Findings of this study serve as a basis for the development of new pessary designs.


Subject(s)
Pelvic Organ Prolapse , Urinary Bladder Diseases , Female , Humans , Pessaries , Cross-Sectional Studies , Vagina/diagnostic imaging , Pelvic Organ Prolapse/diagnostic imaging , Pelvic Organ Prolapse/therapy
19.
Int Urogynecol J ; 34(8): 1971-1982, 2023 08.
Article in English | MEDLINE | ID: mdl-37119270

ABSTRACT

INTRODUCTION AND HYPOTHESIS: Injury of the levator ani muscle (LAM) is a significant risk factor for pelvic organ prolapse (POP). The puborectalis (PRM) and pubovisceral (PVM) subdivisions are level III vaginal support structures. The null hypothesis was that there is no significant difference in patterns of LAM subdivisions in healthy nulliparous women. Secondarily, we evaluated the presence of different LAM injury in a POP-symptomatic cohort. METHODS: This retrospective magnetic resonance imaging study included: 64 nulligravidae without any pelvic floor dysfunction (PFD) and 526 women of various parity with symptomatic POP. Primary outcome was PVM and PRM morphology on the axial planes: the attachment site on the pubic bone, and the visible separation/border between the PVM and PRM. The attachment was scored as "normal" or "abnormal". The "abnormal" attachment was divided in two types: "type I"-loss of the muscle substance, but preservation of the overall muscle architecture-and "type II"-muscle detachment from the pubic bone. RESULTS: The puboanal muscle (PAM) subdivision was evaluated as a representative part of the PVM. The PAM and PRM attachments and separation were distinguished in all asymptomatic nulliparae. PAM and PRM attachments did not significantly differ. POP group characteristics were parity 1.9 ± 0.8, instrumental delivery 5.6%, hysterectomy or POP surgery 60%, all Pelvic Organ Prolapse Quantification (POP-Q) stages, LAM defect 77.6% (PRM: 77.1%; PAM: 51.3%). Type I injuries were more frequent (PRM 54.7%; PAM 53.9%) compared with type II (PRM 29.4%; PAM 42.1%). CONCLUSIONS: A LAM defect was present in 77.6% of women with symptomatic POP. In PRM and PAM subdivisions type I injury was more frequent than type II.


Subject(s)
Pelvic Organ Prolapse , Vagina , Pregnancy , Female , Humans , Retrospective Studies , Vagina/diagnostic imaging , Pelvic Organ Prolapse/diagnostic imaging , Pelvic Organ Prolapse/etiology , Pelvic Floor/injuries , Magnetic Resonance Imaging
20.
J Minim Invasive Gynecol ; 30(4): 262-263, 2023 04.
Article in English | MEDLINE | ID: mdl-36754275

ABSTRACT

OBJECTIVE: To demonstrate vaginoscopic resection of the oblique vaginal septum in a girl with Obstructed Hemi Vagina and Ipsilateral Renal Agenesis (OHVIRA) syndrome before menarche. DESIGN: Stepwise demonstration of surgical technique with narrated video footage. SETTING: OHVIRA syndrome is a rare urogenital anomaly in which patients present after menarche, with progressive dysmenorrhea and a palpable pelvic mass due to hematocolpos and hematometra on the obstructed side. Delay in diagnosis may cause endometriosis, pelvic adhesions, and infertility [1,2]. A 12-year-old, premenarchal girl with complaints of pelvic pain and an ultrasound report of right renal agenesis was referred to the urology department of our hospital. She was also found to have uterus didelphys and a loculated fluid collection behind the urinary bladder on ultrasonography and on magnetic resonance imaging (Figs. 1 and 2). A probable diagnosis of OHVIRA syndrome with mucocolpos was made [3]. INTERVENTION: Vaginoscopy showed an obstructing bulging vaginal septum on the right side. The left uterine horn was inspected by hysteroscopy. The vaginal septum was incised vaginoscopically with monopolar cautery using Collins knife (Video still 1) [4-6]. The collected mucus was drained. The right cervix and the right uterine horn were visualized by hysteroscopy. Edges of the septum were resected with a resectoscope loop (Video still 2). The hymen was not injured during the surgery. Relook vaginoscopy done after 2 months showed a normal and healed vagina. CONCLUSION: Vaginoscopic resection of the obstructing oblique vaginal septum in OHVIRA syndrome is a very simple, minimally invasive, and virginity conserving surgery. Early diagnosis and treatment can prevent future complications due to cryptomenorrhea.


Subject(s)
Kidney Diseases , Menarche , Child , Female , Humans , Kidney/abnormalities , Uterus/diagnostic imaging , Uterus/surgery , Uterus/abnormalities , Vagina/diagnostic imaging , Vagina/surgery , Vagina/abnormalities
SELECTION OF CITATIONS
SEARCH DETAIL