1.
Catheter Cardiovasc Interv ; 99(3): 754-762, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34791755

RESUMEN

OBJECTIVES: We investigated the clinical efficacy of a paclitaxel-coated balloon (PCB) with a novel matrix coating and reduced drug concentration in comparison with a widely used PCB with iopromide excipient. METHODS: We prospectively enrolled patients with restenosis in drug-eluting stents. All patients were treated with a novel low-dose PCB with citrate-based excipient (Agent PCB). Angiographic follow-up was scheduled at 6-8 months. Outcomes were compared against those of patients treated with iopromide excipient PCB (SeQuent Please PCB) enrolled in a trial with identical inclusion and exclusion criteria. The primary endpoint was percent diameter stenosis (%DS) at follow-up angiography. The primary hypothesis was that the investigational device would be non-inferior to the control device (ClinicalTrials.gov Identifier: NCT02367495). RESULTS: One hundred twenty-five patients with 151 lesions were enrolled. Mean age was 68.1 ± 10.2 years, 40.8% had diabetes mellitus and 80.1% had focal morphology in-stent restenosis. Follow-up angiography data at 6-8 months was available for 102 (81.6%) patients. The Agent PCB was non-inferior to the SeQuent Please PCB in terms of the primary endpoint (38.9 ± 17.5 vs. 38.1 ± 21.5%; p non-inferiority  = 0.0056). Late lumen loss was also comparable between the groups (0.35 ± 0.55 vs. 0.37 ± 0.59; p = 0.71). There was no difference between the groups in the incidence of TLR (27.7% vs. 22.1%; p = 0.31), death or myocardial infarction (4.2% vs. 4.4%; p = 0.92) or target lesion thrombosis (1.0% vs. 0.7%; p = 0.93). CONCLUSION: In patients with DES restenosis, angioplasty with a novel PCB with citrate-based excipient was non-inferior to PCB with iopromide excipient in terms of angiographic outcome.


Asunto(s)
Angioplastia Coronaria con Balón , Fármacos Cardiovasculares , Reestenosis Coronaria , Stents Liberadores de Fármacos , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Constricción Patológica/inducido químicamente , Constricción Patológica/complicaciones , Angiografía Coronaria/efectos adversos , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Humanos , Persona de Mediana Edad , Paclitaxel/efectos adversos , Estudios Prospectivos , Stents/efectos adversos , Resultado del Tratamiento
2.
Int J Cardiol ; 252: 57-62, 2018 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-29203209

RESUMEN

BACKGROUND: Angioplasty with paclitaxel-coated balloons (PCB) is recommended for treatment of patients with coronary in-stent restenosis (ISR) according to European clinical practice guidelines. Most clinical trials have investigated iopromide-based PCB and there is a paucity of data comparing efficacy against butyryl-tri-hexyl citrate (BTHC)-based PCB. Our aim was to compare the performance of two widely-used PCB in the treatment of coronary ISR. METHODS: We analysed patients treated with BTHC- or iopromide-PCB for treatment of drug-eluting stent ISR in the setting of 2 consecutive trials with identical inclusion and exclusion criteria. The primary endpoint was diameter stenosis at 6-8month angiographic surveillance. The secondary endpoint of interest was the composite of death, myocardial infarction (MI) or target-lesion revascularisation (TLR) at 1year. Multivariate analysis was performed to adjust for differences in baseline characteristics between groups. RESULTS: In total, 264 patients were treated with BTHC-PCB (n=127) or iopromide-PCB (n=137). Baseline patient characteristics were similar for both groups. Post-procedure stenosis was slightly larger with BTHC-PCB (22.3 [SD 8.2]% vs. 18.4 [SD 9.9]%, P=0.001). At 6-8month angiography, diameter stenosis was 40.4 [SD 21.9]% vs. 37.4 [SD 21.4]% in the BTHC-PCB and iopromide-PCB groups, respectively (P=0.16, Padjusted=0.32). At 1year, death, MI or TLR occurred in 29 (23.2%) vs. 32 (23.4%) patients in the BTHC-PCB and iopromide-PCB groups, respectively (HR 1.03 [95% CI 0.62-1.70], P=0.91, Padjusted=0.96). CONCLUSIONS: In patients undergoing intervention for ISR, angioplasty with BTHC-PCB showed similar angiographic and clinical results at 1year compared with iopromide-PCB.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Materiales Biocompatibles Revestidos/administración & dosificación , Angiografía Coronaria/métodos , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Anciano , Angioplastia Coronaria con Balón/normas , Materiales Biocompatibles Revestidos/normas , Angiografía Coronaria/normas , Stents Liberadores de Fármacos/normas , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Diseño de Prótesis/normas , Resultado del Tratamiento