Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anal Bioanal Chem ; 412(15): 3629-3637, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32239258

RESUMEN

Histamine intolerance results from a disequilibrium of accumulated histamine and the capacity for histamine degradation. An impaired histamine degradation based on reduced DAO activity and the resulting histamine excess may cause numerous symptoms mimicking an allergic reaction. For that, the determination of histamine in blood or in food products has great importance to identify risk factors. A new histamine-selective electrode is proposed using cucurbit[6]uril (CB[6]), as ionophore, in the analysis of biological samples. The selection of this smart supramolecular organic framework was based on its apparent stability constant of histamine-CB[6] (log ß) of 4.33. The optimized electrode based on a polymeric membrane (PVC) combines the histamine-selective ionophore with 2-nitrophenyl octyl ether as solvent mediator and potassium tetrakis(4-chlorophenyl)borate as anionic additive. Furthermore, multi-walled carbon nanotubes particles were included in the membrane composition to partly lower the detection limit of the method, while improving stability and lowering the response drift (± 4 mV). The electrodes showed a rapid response (≃ 13 s) in the pH operational range of 2.7-5.4, with a Nernstian slope of 30.9 ± 1.2 mV/dec, a detection limit of (3.00 ± 0.61) × 10-7 mol/L, and a lower limit of the linear range of (3.00 ± 0.00) × 10-7 mol/L. After miniaturization, the electrode was used as a detector in a sequential-injection lab-on-valve flow setup. The optimized flow conditions were achieved for sample injection volumes of 197 µL propelled towards the cell under detection, at a flow rate of 30 µL/s during 100 s, making the analysis of 30 samples per hour possible. The developed system was used to analyze spiked blood serum samples previously cleaned by using solid-phase extraction. The sample pretreatment of the serum samples using Oasis MCX cartridges showed outstanding efficiency for histamine determination. The recovery values for three different levels of histamine concentration (1 × 10-4 mol/L, 1 × 10-5 mol/L, and 1 × 10-6 mol/L) were (97 ± 6)%, (103 ± 1)%, and (118 ± 9)%, respectively, showing that this method was suitable for biological samples.


Asunto(s)
Hidrocarburos Aromáticos con Puentes/química , Histamina/sangre , Imidazoles/química , Potenciometría/instrumentación , Electrodos , Diseño de Equipo , Humanos , Membranas Artificiales , Miniaturización , Potenciometría/economía , Potenciometría/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA