Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 209
Filtrar
Más filtros

Intervalo de año de publicación
1.
N Engl J Med ; 383(15): 1447-1457, 2020 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-32865376

RESUMEN

BACKGROUND: The effect of single as compared with dual antiplatelet treatment on bleeding and thromboembolic events after transcatheter aortic-valve implantation (TAVI) in patients who do not have an indication for long-term anticoagulation has not been well studied. METHODS: In a randomized, controlled trial, we assigned a subgroup of patients who were undergoing TAVI and did not have an indication for long-term anticoagulation, in a 1:1 ratio, to receive aspirin alone or aspirin plus clopidogrel for 3 months. The two primary outcomes were all bleeding (including minor, major, and life-threatening or disabling bleeding) and non-procedure-related bleeding over a period of 12 months. Most bleeding at the TAVI puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2) at 1 year, with both outcomes tested sequentially for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: A total of 331 patients were assigned to receive aspirin alone and 334 were assigned to receive aspirin plus clopidogrel. A bleeding event occurred in 50 patients (15.1%) receiving aspirin alone and in 89 (26.6%) receiving aspirin plus clopidogrel (risk ratio, 0.57; 95% confidence interval [CI], 0.42 to 0.77; P = 0.001). Non-procedure-related bleeding occurred in 50 patients (15.1%) and 83 patients (24.9%), respectively (risk ratio, 0.61; 95% CI, 0.44 to 0.83; P = 0.005). A secondary composite 1 event occurred in 76 patients (23.0%) receiving aspirin alone and in 104 (31.1%) receiving aspirin plus clopidogrel (difference, -8.2 percentage points; 95% CI for noninferiority, -14.9 to -1.5; P<0.001; risk ratio, 0.74; 95% CI for superiority, 0.57 to 0.95; P = 0.04). A secondary composite 2 event occurred in 32 patients (9.7%) and 33 patients (9.9%), respectively (difference, -0.2 percentage points; 95% CI for noninferiority, -4.7 to 4.3; P = 0.004; risk ratio, 0.98; 95% CI for superiority, 0.62 to 1.55; P = 0.93). A total of 44 patients (13.3%) and 32 (9.6%), respectively, received oral anticoagulation during the trial. CONCLUSIONS: Among patients undergoing TAVI who did not have an indication for oral anticoagulation, the incidence of bleeding and the composite of bleeding or thromboembolic events at 1 year were significantly less frequent with aspirin than with aspirin plus clopidogrel administered for 3 months. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Asunto(s)
Aspirina/uso terapéutico , Clopidogrel/uso terapéutico , Hemorragia/inducido químicamente , Inhibidores de Agregación Plaquetaria/uso terapéutico , Trombosis/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Administración Oral , Anciano , Anciano de 80 o más Años , Aspirina/efectos adversos , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/mortalidad , Clopidogrel/efectos adversos , Quimioterapia Combinada , Femenino , Hemorragia/epidemiología , Humanos , Incidencia , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Periodo Posoperatorio , Trombosis/epidemiología
2.
N Engl J Med ; 382(18): 1696-1707, 2020 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-32223116

RESUMEN

BACKGROUND: The roles of anticoagulation alone or with an antiplatelet agent after transcatheter aortic-valve implantation (TAVI) have not been well studied. METHODS: We performed a randomized trial of clopidogrel in patients undergoing TAVI who were receiving oral anticoagulation for appropriate indications. Patients were assigned before TAVI in a 1:1 ratio not to receive clopidogrel or to receive clopidogrel for 3 months. The two primary outcomes were all bleeding and non-procedure-related bleeding over a period of 12 months. Procedure-related bleeding was defined as Bleeding Academic Research Consortium type 4 severe bleeding, and therefore most bleeding at the puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction at 12 months (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2), both tested for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: Bleeding occurred in 34 of the 157 patients (21.7%) receiving oral anticoagulation alone and in 54 of the 156 (34.6%) receiving oral anticoagulation plus clopidogrel (risk ratio, 0.63; 95% confidence interval [CI], 0.43 to 0.90; P = 0.01); most bleeding events were at the TAVI access site. Non-procedure-related bleeding occurred in 34 patients (21.7%) and in 53 (34.0%), respectively (risk ratio, 0.64; 95% CI, 0.44 to 0.92; P = 0.02). Most bleeding occurred in the first month and was minor. A secondary composite 1 event occurred in 49 patients (31.2%) receiving oral anticoagulation alone and in 71 (45.5%) receiving oral anticoagulation plus clopidogrel (difference, -14.3 percentage points; 95% CI for noninferiority, -25.0 to -3.6; risk ratio, 0.69; 95% CI for superiority, 0.51 to 0.92). A secondary composite 2 event occurred in 21 patients (13.4%) and in 27 (17.3%), respectively (difference, -3.9 percentage points; 95% CI for noninferiority, -11.9 to 4.0; risk ratio, 0.77; 95% CI for superiority, 0.46 to 1.31). CONCLUSIONS: In patients undergoing TAVI who were receiving oral anticoagulation, the incidence of serious bleeding over a period of 1 month or 1 year was lower with oral anticoagulation alone than with oral anticoagulation plus clopidogrel. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Asunto(s)
Anticoagulantes/uso terapéutico , Clopidogrel/uso terapéutico , Hemorragia/inducido químicamente , Inhibidores de Agregación Plaquetaria/uso terapéutico , Reemplazo de la Válvula Aórtica Transcatéter , Administración Oral , Anciano , Anciano de 80 o más Años , Anticoagulantes/efectos adversos , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/mortalidad , Clopidogrel/efectos adversos , Quimioterapia Combinada , Hemorragia/epidemiología , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
3.
Catheter Cardiovasc Interv ; 101(6): 1128-1133, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36994878

RESUMEN

OBJECTIVES: The current study sought to determine whether low-dose dobutamine stress echocardiography (DSE) during transcatheter edge-to-edge mitral valve repair (TMVR) can predict residual mitral regurgitation (MR) at discharge. BACKGROUND: In most patients, TMVR can successfully reduce MR from severe to mild or moderate. However, general anesthesia during the intervention affects hemodynamics and MR assessment. At discharge transthoracic echocardiogram residual MR (>moderate) is present in 10%-30% of patients which is associated with worse clinical outcome. METHODS: In consecutive patients the severity of MR was determined at baseline, immediately after TMVR clip implantation and subsequently during low-dose DSE (both under general anesthesia) and at discharge. RESULTS: A total of 39 patients were included (mean age 76.1 ± 8.1 years, 39% male, 56% functional MR, 41% left ventricular ejection fraction < 45%). An increase of MR during DSE was seen in 11 patients, of whom 6 (55%) showed >moderate MR at discharge. None of the 28 patients without an increase of MR during DSE showed >moderate MR at discharge. The diagnostic performance of the test could be established at a sensitivity of 100% and a specificity of 85% in unselected patients. CONCLUSIONS: DSE during TMVR is a useful tool to predict residual MR at discharge. It could support procedural decision making, including implantation of additional clips and thus potentially improve clinical outcome.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Femenino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Volumen Sistólico , Ecocardiografía de Estrés , Resultado del Tratamiento , Función Ventricular Izquierda , Cateterismo Cardíaco/efectos adversos
4.
Neth Heart J ; 31(12): 461-470, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37910335

RESUMEN

BACKGROUND: Approximately one-third of patients with symptomatic severe aortic valve stenosis who are scheduled for transcatheter aortic valve implantation (TAVI) have some degree of cognitive impairment. TAVI may have negative cognitive effects due to periprocedural micro-emboli inducing cerebral infarction. On the contrary, TAVI may also have positive cognitive effects due to increases in cardiac output and cerebral blood flow (CBF). However, studies that systematically assess these effects are scarce. Therefore, the main aim of this study is to assess cerebral and cognitive outcomes in patients with severe aortic valve stenosis undergoing TAVI. STUDY DESIGN: In the prospective CAPITA (CArdiac OutPut, Cerebral Blood Flow and Cognition In Patients With Severe Aortic Valve Stenosis Undergoing Transcatheter Aortic Valve Implantation) study, cerebral and cognitive outcomes are assessed in patients undergoing TAVI. One day before and 3 months after TAVI, patients will undergo echocardiography (cardiac output, valve function), brain magnetic resonance imaging (CBF, structural lesions) and extensive neuropsychological assessment. To assess longer-term effects of TAVI, patients will again undergo echocardiography and neuropsychological assessment 1 year after the procedure. The co-primary outcome measures are change in CBF (in ml/100 g per min) and change in global cognitive functioning (Z-score) between baseline and 3­month follow-up. Secondary objectives include change in cardiac output, white matter hyperintensities and other structural brain lesions. (ClinicalTrials.gov identifier NCT05481008) CONCLUSION : The CAPITA study is the first study designed to systematically assess positive and negative cerebral and cognitive outcomes after TAVI. We hypothesise that TAVI improves cardiac output, CBF and cognitive functioning.

5.
Cardiovasc Diabetol ; 21(1): 246, 2022 11 16.
Artículo en Inglés | MEDLINE | ID: mdl-36384656

RESUMEN

BACKGROUND: Diabetes Mellitus (DM) affects a third of patients with symptomatic severe aortic valve stenosis undergoing transcatheter aortic valve implantation (TAVI). DM is a well-known risk factor for cardiac surgery, but its prognostic impact in TAVI patients remains controversial. This study aimed to evaluate outcomes in diabetic patients undergoing TAVI. METHODS: This multicentre registry includes data of > 12,000 patients undergoing transfemoral TAVI. We assessed baseline patient characteristics and clinical outcomes in patients with DM and without DM. Clinical outcomes were defined by the second valve academic research consortium. Propensity score matching was applied to minimize potential confounding. RESULTS: Of the 11,440 patients included, 31% (n = 3550) had DM and 69% (n = 7890) did not have DM. Diabetic patients were younger but had an overall worse cardiovascular risk profile than non-diabetic patients. All-cause mortality rates were comparable at 30 days (4.5% vs. 4.9%, RR 0.9, 95%CI 0.8-1.1, p = 0.43) and at one year (17.5% vs. 17.4%, RR 1.0, 95%CI 0.9-1.1, p = 0.86) in the unmatched population. Propensity score matching obtained 3281 patient-pairs. Also in the matched population, mortality rates were comparable at 30 days (4.7% vs. 4.3%, RR 1.1, 95%CI 0.9-1.4, p = 0.38) and one year (17.3% vs. 16.2%, RR 1.1, 95%CI 0.9-1.2, p = 0.37). Other clinical outcomes including stroke, major bleeding, myocardial infarction and permanent pacemaker implantation, were comparable between patients with DM and without DM. Insulin treated diabetics (n = 314) showed a trend to higher mortality compared with non-insulin treated diabetics (n = 701, Hazard Ratio 1.5, 95%CI 0.9-2.3, p = 0.08). EuroSCORE II was the most accurate risk score and underestimated 30-day mortality with an observed-expected ratio of 1.15 in DM patients, STS-PROM overestimated actual mortality with a ratio of 0.77 and Logistic EuroSCORE with 0.35. CONCLUSION: DM was not associated with mortality during the first year after TAVI. DM patients undergoing TAVI had low rates of mortality and other adverse clinical outcomes, comparable to non-DM TAVI patients. Our results underscore the safety of TAVI treatment in DM patients. TRIAL REGISTRATION: The study is registered at clinicaltrials.gov (NCT03588247).


Asunto(s)
Estenosis de la Válvula Aórtica , Diabetes Mellitus , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Diabetes Mellitus/etiología , Puntaje de Propensión , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Multicéntricos como Asunto , Sistema de Registros
6.
Eur Radiol ; 32(1): 143-151, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34132873

RESUMEN

OBJECTIVES: Computed tomography angiography (CTA) is performed routinely in the work-up for transcatheter aortic valve implantation (TAVI), and could potentially replace invasive coronary angiography (ICA) to rule out left main (LM) and proximal coronary stenosis. The objectives were to assess the diagnostic yield and accuracy of pre-TAVI CTA to detect LM and proximal coronary stenosis of ≥ 50% and ≥ 70% diameter stenosis (DS). METHODS: The DEPICT CTA database consists of individual patient data from four studies with a retrospective design that analyzed the diagnostic accuracy of pre-TAVI CTA to detect coronary stenosis, as compared with ICA. Pooled data were used to assess diagnostic accuracy to detect coronary stenosis in the left main and the three proximal coronary segments on a per-patient and a per-segment level. We included 1060 patients (mean age: 81.5 years, 42.7% male). RESULTS: On ICA, the prevalence of proximal stenosis was 29.0% (≥ 50% DS) and 15.7% (≥ 70% DS). Pre-TAVI CTA ruled out ≥ 50% DS in 51.6% of patients with a sensitivity of 96.4%, specificity of 71.2%, PPV of 57.7%, and NPV of 98.0%. For ≥ 70% DS, pre-TAVI CTA ruled out stenosis in 70.0% of patients with a sensitivity of 96.7%, specificity of 87.5%, PPV of 66.9%, and NPV of 99.0%. CONCLUSION: CTA provides high diagnostic accuracy to rule out LM and proximal coronary stenosis in patients undergoing work-up for TAVI. Clinical application of CTA as a gatekeeper for ICA would reduce the need for ICA in 52% or 70% of patients, using a threshold of ≥ 50% or ≥ 70% DS, respectively. KEY POINTS: • Clinical application of CTA as a gatekeeper for ICA would reduce the need for ICA in 52% or 70% of TAVI patients, using a threshold of ≥ 50% or ≥ 70% diameter stenosis. • The diagnostic accuracy of CTA to exclude proximal coronary stenosis in these patients is high, with a sensitivity of 96.4% and NPV of 98.0% for a threshold of ≥ 50%, and a sensitivity of 96.7% and NPV of 99.0% for a threshold of ≥ 70% diameter stenosis. • Atrial fibrillation and heart rate did not significantly affect sensitivity and NPV. However, a heart rate of < 70 b/min during CTA was associated with a significantly improved specificity and PPV.


Asunto(s)
Estenosis de la Válvula Aórtica , Estenosis Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Estudios Retrospectivos
7.
Heart Lung Circ ; 31(5): 696-704, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35058141

RESUMEN

BACKGROUND: Pulmonary hypertension (PH), right ventricular (RV) dysfunction, and tricuspid regurgitation (TR) are commonly present in patients with mitral regurgitation (MR) and known to impair prognosis. This systematic review and meta-analysis aimed to determine the prognostic value of PH, RV function, and TR on mortality after transcatheter mitral valve repair (TMVR). METHODS: A systematic search was performed to identify studies investigating PH, RV function, or TR in patients who underwent TMVR. Studies were included for pooled analysis if hazard ratios (HR) for all-cause mortality were given. RESULTS: A total of 8,672 patients from 21 selected studies were included (PH, 11 studies; RV function, nine studies; TR, 10 studies). Mean follow-up was 2.7±1.6 years. The HRs and 95% CIs for all-cause mortality of PH (dichotomised: HR 1.70, 95% CI 1.00-2.87; per 10 mmHg increase in systolic PAP: HR 1.17, 95% CI 1.07-1.29), RV function (dichotomised: HR 1.86, 95% CI 1.45-2.38; per 5 mm decrease in TAPSE: HR 1.18, 95% CI 0.97-1.43) and TR (HR 1.51, 95% CI 1.28-1.79) indicated a significant association. CONCLUSION: Prognosis after TMVR is worse in patients with significant MR when concomitant PH, RV dysfunction, or TR are present. Careful assessment of these parameters should therefore precede clinical decision-making for TMVR. The current results encourage investigation into whether (1) intervention at an earlier stage of MR reduces incidence of PH, RV dysfunction, and TR; and (2) transcatheter treatment of concomitant TR can improve clinical outcome and prognosis for these patients.


Asunto(s)
Hipertensión Pulmonar , Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Humanos , Hipertensión Pulmonar/complicaciones , Válvula Mitral , Insuficiencia de la Válvula Mitral/etiología , Pronóstico , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Función Ventricular Derecha
8.
Catheter Cardiovasc Interv ; 98(3): E427-E435, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33458911

RESUMEN

OBJECTIVES: The aim of this study was to determine the course of tricuspid regurgitation (TR) after transcatheter mitral valve repair (TMVR), identify predictors for severe TR after TMVR and determine the association of severe TR after TMVR with outcome. BACKGROUND: TR is often present in patients with symptomatic mitral regurgitation (MR) and is associated with increased morbidity and mortality. The clinical course of TR after TMVR has not been clearly determined. METHODS: Patients that underwent TMVR between 2009 and 2017 were included. Clinical data were compared between patients with and without severe TR at 6 months after TMVR. Multivariate logistic regression analysis was performed to identify predictors for severe TR after TMVR. Survival analysis was done for both groups, using the Kaplan-Meier method. RESULTS: A total of 146 patients were included (mean age 76 years, 51% male, 79% New York Heart Association class ≥3 and 29% severe TR at baseline). Advanced age, atrial fibrillation (AF), right ventricular (RV) dysfunction, and limited procedural MR reduction were revealed as independent predictors for severe TR after TMVR. Survival of patients with severe TR after TMVR was 58% after 2 years compared to 82% for those with non, mild or moderate TR. CONCLUSIONS: Severe TR after TMVR is common in patients at advanced age, those with AF, RV dysfunction and limited MR reduction during TMVR and is associated with impaired survival. As the associated parameters are indicators of longstanding MR, research investigating the benefits of earlier intervention in MR should be initiated.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Anciano , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
9.
N Engl J Med ; 376(24): 2319-2328, 2017 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-28402237

RESUMEN

BACKGROUND: Bioresorbable vascular scaffolds were developed to overcome the shortcomings of drug-eluting stents in percutaneous coronary intervention (PCI). We performed an investigator-initiated, randomized trial to compare an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent in the context of routine clinical practice. METHODS: We randomly assigned 1845 patients undergoing PCI to receive either a bioresorbable vascular scaffold (924 patients) or a metallic stent (921 patients). The primary end point was target-vessel failure (a composite of cardiac death, target-vessel myocardial infarction, or target-vessel revascularization). The data and safety monitoring board recommended early reporting of the study results because of safety concerns. This report provides descriptive information on end-point events. RESULTS: The median follow-up was 707 days. Target-vessel failure occurred in 105 patients in the scaffold group and in 94 patients in the stent group (2-year cumulative event rates, 11.7% and 10.7%, respectively; hazard ratio, 1.12; 95% confidence interval [CI], 0.85 to 1.48; P=0.43); event rates were based on Kaplan-Meier estimates in time-to-event analyses. Cardiac death occurred in 18 patients in the scaffold group and in 23 patients in the stent group (2-year cumulative event rates, 2.0% and 2.7%, respectively), target-vessel myocardial infarction occurred in 48 patients in the scaffold group and in 30 patients in the stent group (2-year cumulative event rates, 5.5% and 3.2%), and target-vessel revascularization occurred in 76 patients in the scaffold group and in 65 patients in the stent group (2-year cumulative event rates, 8.7% and 7.5%). Definite or probable device thrombosis occurred in 31 patients in the scaffold group as compared with 8 patients in the stent group (2-year cumulative event rates, 3.5% vs. 0.9%; hazard ratio, 3.87; 95% CI, 1.78 to 8.42; P<0.001). CONCLUSIONS: In this preliminary report of a trial involving patients undergoing PCI, there was no significant difference in the rate of target-vessel failure between the patients who received a bioresorbable scaffold and the patients who received a metallic stent. The bioresorbable scaffold was associated with a higher incidence of device thrombosis than the metallic stent through 2 years of follow-up. (Funded by Abbott Vascular; AIDA ClinicalTrials.gov number, NCT01858077 .).


Asunto(s)
Implantes Absorbibles , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Stents Metálicos Autoexpandibles , Implantes Absorbibles/efectos adversos , Anciano , Everolimus/administración & dosificación , Femenino , Estudios de Seguimiento , Cardiopatías/mortalidad , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Stents Metálicos Autoexpandibles/efectos adversos , Trombosis/epidemiología , Trombosis/etiología , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 95(1): 89-96, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-30968559

RESUMEN

BACKGROUND: Patients with acute coronary syndrome (ACS) might represent a specific subgroup, in which bioresorbable scaffold implantation in percutaneous coronary intervention (PCI), might lead to better outcomes when compared to conventional treatment with metallic drug eluting stents. In this prespecified subgroup analysis of the Amsterdam Investigator-Initiated Absorb Strategy All-Comers (AIDA) trial, we evaluated the clinical outcomes of Absorb bioresorbable vascular scaffold (BVS) versus Xience everolimus eluting stent (EES) treated patients presenting either with or without ACS. METHODS AND RESULTS: We classified AIDA patients on the basis of clinical presentation of ACS or of no-ACS. The rate of the 2-year primary endpoint of target vessel failure (TVF) was similar after treatment with Absorb BVS or Xience EES in ACS patients (10.2% versus 9.0% respectively; P = 0.49) and in no-ACS patients (11.7% versus 10.7%, respectively; P = 0.67) Definite or probable device thrombosis occurred more frequently with Absorb BVS compared to Xience EES in ACS patients (4.3% versus 1.7%, respectively, P = 0.03) as well as in no-ACS patients (2.4% versus 0.2%, respectively; P = 0.002). There were no statistically significant interactions between clinical presentation and randomized device modality for TVF (P = 0.80) and for the endpoint of definite or probable device thrombosis (P = 0.17). CONCLUSION: In the AIDA trial, the 2-year outcomes of PCI with Absorb BVS versus Xience EES were consistent in ACS and no-ACS patients: similar rates for TVF and consistently higher rates of definite or probable stent thrombosis under Absorb BVS versus Xience EES. There were no statistically significant interactions between clinical presentation and randomized device modality.


Asunto(s)
Implantes Absorbibles , Síndrome Coronario Agudo/terapia , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Metales , Intervención Coronaria Percutánea/instrumentación , Síndrome Coronario Agudo/diagnóstico por imagen , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Trombosis Coronaria/etiología , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Factores de Riesgo , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
11.
Heart Vessels ; 35(12): 1735-1745, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32591894

RESUMEN

Permanent pacemaker implantation (PPI) is a widely recognized complication associated with TAVI (incidence up to 20%). Smaller registries have identified several variables associated with PPI. The objective was to validate patient- and transcatheter aortic valve implantation (TAVI)-related procedural variables associated with PPI. We performed a retrospective analysis of patients from six European centers undergoing TAVI with the Edwards SAPIEN 3 prosthesis. Baseline variables and pre-procedural ECG characteristics and CT-scans were taken into account. Data for 1745 patients were collected; 191 (10.9%) required PPI after TAVI. The baseline variables pulmonary hypertension (OR 1.64; 95% CI 1.01-2.59), QRS duration > 117 ms (OR 2.58; 95% CI 1.73-3.84), right bundle branch block (RBBB; OR 5.14; 95% CI 3.39-7.72), left anterior hemi block (OR 1.92; 95% CI 1.19-3.02) and first-degree atrioventricular block (AVB, OR 1.63; 95%CI 1.05-2.46) were significantly associated with PPI. RBBB (OR 8.11; 95% CI 3.19-21.86) and first-degree AVB (OR 2.39; 95% CI 1.18-4.66) remained significantly associated in a multivariate analysis. Procedure-related variables included access site (TF; OR 1.97; 95% CI 1.07-4.05), implanted valve size (29 mm; OR 1.88; 95% CI 1.35-2.59), mean TAVI valve implantation depth below the annulus > 30% (OR 3.75; 95% CI 2.01-6.98). Patients receiving PPI had longer ICU stays and later discharges. Acute kidney injury stage 2/3 was more common in patients with PPI until discharge (15.2 vs. 3.1%; p = 0.007), but was not statistically significant thereafter. Further differences in outcomes at 30 days did not reach significance. The data will aid pre- and post-procedural patient management and prevent adverse long-term outcomes.Clinical Trial: NCT03497611.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón/efectos adversos , Estimulación Cardíaca Artificial , Bloqueo Cardíaco/terapia , Frecuencia Cardíaca , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Europa (Continente) , Femenino , Bloqueo Cardíaco/diagnóstico , Bloqueo Cardíaco/etiología , Bloqueo Cardíaco/fisiopatología , Humanos , Masculino , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
12.
Eur Heart J ; 40(5): 456-465, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30590565

RESUMEN

Aims: The aim of this study was to compare clinical outcomes of patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) with balloon-expandable (BE) valves vs. self-expandable (SE) valves. Transcatheter aortic valve implantation is a minimally invasive and lifesaving treatment in patients with aortic valve stenosis. Even though BE-valves and SE-valves are both commonly used on a large scale, adequately sized trials comparing clinical outcomes in patients with severe aortic valve stenosis treated with BE-valves compared with SE-valves are lacking. Methods and results: In this CENTER-collaboration, data from 10 registries or clinical trials, selected through a systematic search, were pooled and analysed. Propensity score methodology was used to reduce treatment selection bias and potential confounding. The primary endpoints were mortality and stroke at 30 days follow-up in patients treated with BE-valves compared with SE-valves. Secondary endpoints included clinical outcomes, e.g. bleeding during hospital admission. All outcomes were split for early-generation BE-valves compared with early-generation SE-valves and new-generation BE-valves with new-generation SE-valves. The overall patient population (N = 12 381) included 6239 patients undergoing TAVI with BE-valves and 6142 patients with SE-valves. The propensity matched population had a mean age of 81 ± 7 years and a median STS-PROM score or 6.5% [interquartile range (IQR) 4.0-13.0%]. At 30-day follow-up, the mortality rate was not statistically different in patients undergoing TAVI with BE-valves compared with SE-valves [BE: 5.3% vs. SE: 6.2%, relative risk (RR) 0.9; 95% confidence interval (CI) 0.7-1.0, P = 0.10]. Stroke occurred less frequently in patients treated with BE-valves (BE: 1.9% vs. SE: 2.6%, RR 0.7; 95% CI 0.5-1.0, P = 0.03). Also, patients treated with BE-valves had a three-fold lower risk of requiring pacemaker implantation (BE: 7.8% vs. SE: 20.3%, RR 0.4; 95% CI 0.3-0.4, P < 0.001). In contrast, patients treated with new-generation BE-valves more frequently experienced major and life-threatening bleedings compared with new-generation SE-valves (BE: 4.8% vs. SE: 2.1%, RR 2.3; 95% CI 1.6-3.3, P < 0.001). Conclusion: In this study, which is the largest study to compare valve types in TAVI, we demonstrated that the incidence of stroke and pacemaker implantation was lower in patients undergoing transfemoral TAVI with BE-valves compared with SE-valves. In contrast, patients treated with new-generation BE-valves more often suffered from major or life-threatening bleedings than patients with new-generation SE-valves. Mortality at 30-days was not statistically different in patients treated with BE-valves compared with SE-valves. This study was a propensity-matched analysis generated from observational data, accordingly current outcomes will have to be confirmed in a large scale randomized controlled trial.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Marcapaso Artificial/estadística & datos numéricos , Diseño de Prótesis , Accidente Cerebrovascular/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Conversión a Cirugía Abierta/estadística & datos numéricos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Estudios Observacionales como Asunto , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/mortalidad , Puntaje de Propensión , Sistema de Registros , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
13.
Catheter Cardiovasc Interv ; 93(6): 1146-1149, 2019 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-30508272

RESUMEN

BACKGROUND: High-risk patients with mitral regurgitation (MR) may be treated by a percutaneous mitral valve repair with the MitraClip, but identification of patients who may benefit remains difficult. We aimed to determine whether myocardial fibrosis predicts outcome in MR patients undergoing MitraClip implantation and is beneficial in clinical decision making. METHODS: Preprocedural to the MitraClip implantation, myocardial fibrosis was analyzed with cardiovascular magnetic resonance (CMR) through late gadolinium enhancement. The CMR data were core-lab adjudicated measured before the MitraClip implantation. Adverse outcome was defined as New York Heart Association (NYHA) class III or IV after 1 month or death within 1 month after the MitraClip implantation. RESULTS: In total, 23 patients underwent preprocedural CMR, mean age 80 ± 9 years, 45% male, 64% atrial fibrillation and 73% NYHA class III or IV at baseline. Myocardial fibrosis was present in 55% of the patients with degenerative MR and in 64% of the patients with functional MR. An adverse outcome occurred in 69% of the patients with myocardial fibrosis and in 11% of the patients without myocardial fibrosis (P = 0.01). CONCLUSIONS: Our hypothesis-generating study showed that the presence of myocardial fibrosis predicts adverse outcome in patients undergoing MitraClip implantation. After confirmation with larger sample size, identification of myocardial fibrosis might contribute to assess prognosis and to clinical decision making.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Miocardio/patología , Anciano , Anciano de 80 o más Años , Toma de Decisiones Clínicas , Técnicas de Apoyo para la Decisión , Femenino , Fibrosis , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/patología , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
14.
Catheter Cardiovasc Interv ; 93(2): 216-221, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30232824

RESUMEN

OBJECTIVES: To investigate the relative performance of treatment with a paclitaxel-eluting balloon (PEB) compared with an everolimus-eluting stent (EES) for in-stent restenosis (ISR) in patients with diabetes mellitus (DM). BACKGROUND: ISR remains a challenge in contemporary clinical practice, particularly in patients with DM. METHODS: In the multicenter randomized DARE trial, patients with BMS or DES ISR were randomized in a 1:1 fashion to treatment with a PEB or an EES. Patients underwent angiographic follow-up after 6 months. For the purpose of this analysis, the relative performance of PEB versus EES in diabetic patients was investigated. RESULTS: Of 278 patients enrolled in DARE, 88 (32%) had DM, of whom 46 were randomized to EES and 42 to PEB treatment. Of patients with DM, 48 (55%) had DES-ISR. Angiographic follow-up was available in 30 patients (72%) in the PEB group and 36 patients (78%) in the DES group. There were no differences in terms of 6-months minimal lumen diameter in diabetic patients treated with EES (1.46 ± 0.66 mm) versus PEB (1.78 ± 0.58 mm, P = 0.15). Adverse events at one year follow-up were similar in both groups, with Major Adverse Events (MAE, death, target vessel MI, or TVR) occurring in 17.4% in the EES group versus 11.9% in the PEB group, P = 0.44. CONCLUSIONS: In patients with ISR and DM, use of a PEB resulted in similar 6-months in-segment minimal lumen diameter and comparable rates of MAE. In-segment late loss at 6 months was significantly lower in the PEB arm. Although larger trials in DM patients with ISR are necessary, PEB is a promising treatment option obviating the need for additional stent implantation.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/terapia , Diabetes Mellitus , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Paclitaxel/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Diabetes Mellitus/diagnóstico , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Paclitaxel/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
15.
Catheter Cardiovasc Interv ; 93(4): E248-E254, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30208263

RESUMEN

OBJECTIVES: The aim of this study was to assess the predictive value of PMA measurement for mortality. BACKGROUND: Current surgical risk stratification have limited predictive value in the transcatheter aortic valve implantation (TAVI) population. In TAVI workup, a CT scan is routinely performed but body composition is not analyzed. Psoas muscle area (PMA) reflects a patient's global muscle mass and accordingly PMA might serve as a quantifiable frailty measure. METHODS: Multi-slice computed tomography scans (between 2010 and 2016) of 583 consecutive TAVI patients were reviewed. Patients were divided into equal sex-specific tertiles (low, mid, and high) according to an indexed PMA. Hazard ratios (HR) and their confidence intervals (CI) were determined for cardiac and all-cause mortality after TAVI. RESULTS: Low iPMA was associated with cardiac and all-cause mortality in females. One-year adjusted cardiac mortality HR in females for mid-iPMA and high-iPMA were 0.14 [95%CI, 0.05-0.45] and 0.40 [95%CI, 0.15-0.97], respectively. Similar effects were observed for 30-day and 2-years cardiac and all-cause mortality. In females, adding iPMA to surgical risk scores improved the predictive value for 1-year mortality. C-statistics changed from 0.63 [CI = 0.54-0.73] to 0.67 [CI: 0.58-0.75] for EuroSCORE II and from 0.67 [CI: 0.59-0.77] to 0.72 [CI: 0.63-0.80] for STS-PROM. CONCLUSIONS: Particularly in females, low iPMA is independently associated with an higher all-cause and cardiac mortality. Prospective studies should confirm whether PMA or other body composition parameters should be extracted automatically from CT-scans to include in clinical decision making and outcome prediction for TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Composición Corporal , Fragilidad/diagnóstico por imagen , Tomografía Computarizada Multidetector , Músculos Psoas/diagnóstico por imagen , Sarcopenia/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Fragilidad/mortalidad , Fragilidad/fisiopatología , Estado de Salud , Humanos , Masculino , Valor Predictivo de las Pruebas , Músculos Psoas/fisiopatología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Sarcopenia/mortalidad , Sarcopenia/fisiopatología , Factores Sexuales , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
16.
Catheter Cardiovasc Interv ; 91(7): 1212-1218, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-28868810

RESUMEN

OBJECTIVES: To assess the long-term safety and clinical efficacy of the Genous endothelial progenitor cell capturing stent (ECS) compared with the TAXUS Liberté paclitaxel-eluting stent (PES) in lesions with a high risk of restenosis. BACKGROUND: Instead of the use of cytotoxic or cytostatic drugs in drug-eluting stents, a "pro-healing" approach in ECS may overcome impeded healing response due to delayed functional endothelialization of the stent struts. METHODS: In the prospective, randomized TRIAS pilot study 193 patients with coronary artery lesions carrying a high risk of restenosis were included (ECS: n = 98, PES: n = 95). The primary focus of this analysis was target vessel failure (TVF) at 5 years. Dual antiplatelet therapy was prescribed for ≥1 month after ECS and for ≥6 months after PES. RESULTS: At 5 years follow-up, no significant differences were found in TVF (ECS 24% vs. PES 29%, risk difference 95% confidence interval (RDCI) -17.3% to 7.4%). Between 2 and 5 years after the index procedure, low numbers of TVF were observed in ECS compared with PES (ECS 4% vs. PES 16%, RDCI -20.8% to -2.3%). There was no definite stent thrombosis in ECS compared with four patients in the PES group. CONCLUSION: This is the first randomized study providing very long-term clinical efficacy and safety of the ECS in lesions carrying a high risk of restenosis. At 5 years follow-up, TVF rates in ECS group are numerically lower compared with PES due to an increase of events between 2 and 5 years after the index procedure.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Reestenosis Coronaria/prevención & control , Estenosis Coronaria/cirugía , Vasos Coronarios/cirugía , Stents Liberadores de Fármacos , Células Progenitoras Endoteliales/patología , Paclitaxel/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Fármacos Cardiovasculares/efectos adversos , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/patología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/patología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Humanos , Paclitaxel/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Proyectos Piloto , Inhibidores de Agregación Plaquetaria/administración & dosificación , Estudios Prospectivos , Diseño de Prótesis , Repitelización , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
17.
Eur Radiol ; 28(1): 257-264, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28710578

RESUMEN

OBJECTIVES: To evaluate aortic velocity, wall shear stress (WSS) and viscous energy loss (EL) of stented and stentless bioprostheses using 4D flow MRI 1 year after surgical aortic valve replacement. METHODS: For this cross-sectional study 28 patients with stented (n = 14) or stentless (n = 14) bioprosthesis underwent non-contrast-enhanced 4D-flow MRI at 1.5 T. Analyses included a comparison of velocity, WSS and EL in the ascending aorta during peak systole for both spatially averaged values and a comparison of local differences using per-voxel analysis. RESULTS: No significant differences were found in peak and mean velocity (stented vs. stentless: 2.45 m/s vs. 2.11 m/s; p = 0.09 and 0.60 m/s vs. 0.62 m/s; p = 0.89), WSS (0.60 Pa vs. 0.59 Pa; p = 0.55) and EL (10.17 mW vs. 7.82 mW; p = 0.10). Per-voxel analysis revealed significantly higher central lumen velocity, and lower outer lumen velocity, WSS and EL for stentless versus stented prostheses. CONCLUSION: One year after aortic valve implantation with stented and stentless bioprostheses, velocity, WSS and EL were comparable when assessed for averaged values in the ascending aorta. However, the flow profile described with local analysis for stentless prosthesis is potentially favourable with a significantly higher central velocity profile and lower values for outer lumen velocity, WSS and EL. KEY POINTS: • Stentless bioprostheses can be implanted instead of stented aortic valve bioprostheses. • Haemodynamic performance of valve prosthesis can be assessed using 4D flow MRI. • Averaged ascending aorta PSV, WSS and EL are comparable 1 year post-implantation. • Centreline velocity is highest, WSS and EL is lowest for stentless prosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Stents , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Estudios Transversales , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Diseño de Prótesis , Reproducibilidad de los Resultados
18.
BMC Cardiovasc Disord ; 18(1): 1, 2018 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-29301486

RESUMEN

BACKGROUND: In older patients with aortic stenosis (AS) undergoing TAVI, the potential role of prior CGA is not well established. To explore the value of comprehensive geriatric assessment (CGA) for predicting mortality and/or hospitalisation within the first 3 months after transcatheter aortic valve implantation (TAVI). METHODS: An international, multi-centre, prospective registry (CGA-TAVI) was established to gather data on CGA results and medium-term outcomes in geriatric patients undergoing TAVI. Logistic regression was used to evaluate the predictive value of a multidimensional prognostic index (MPI); a short physical performance battery (SPPB); and the Silver Code, which was based on administrative data, for predicting death and/or hospitalisation in the first 3 months after TAVI (primary endpoint). RESULTS: A total of 71 TAVI patients (mean age 85.4 years; mean log EuroSCORE I 22.5%) were enrolled. Device success according to VARC criteria was 100%. After adjustment for selected baseline characteristics, a higher (poorer) MPI score (OR: 3.34; 95% CI: 1.39-8.02; p = 0.0068) and a lower (poorer) SPPB score (OR: 1.15; 95% CI: 1.01-1.54; p = 0.0380) were found to be associated with an increased likelihood of the primary endpoint. The Silver Code did not show any predictive ability in this population. CONCLUSIONS: Several aspects of the CGA have shown promise for being of use to physicians when predicting TAVI outcomes. While the MPI may be useful in clinical practice, the SPPB may be of particular value, being simple and quick to perform. Validation of these findings in a larger sample is warranted. TRIAL REGISTRATION: The trial was registered in ClinicalTrials.gov on November 7, 2013 ( NCT01991444 ).


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Técnicas de Apoyo para la Decisión , Evaluación Geriátrica , Reemplazo de la Válvula Aórtica Transcatéter , Factores de Edad , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Humanos , Italia , Modelos Logísticos , Masculino , Países Bajos , Oportunidad Relativa , Readmisión del Paciente , Valor Predictivo de las Pruebas , Estudios Prospectivos , Quebec , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
20.
Catheter Cardiovasc Interv ; 90(4): 650-659, 2017 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-28109043

RESUMEN

OBJECTIVES: We sought to investigate a new angiographic method for aortic regurgitation (AR) severity assessment in the setting of transcatheter aortic valve implantation (TAVI). BACKGROUND: AR after TAVI is common but challenging to quantitate, especially in the cath-lab. METHODS: In 228 patients, AR was quantitated before and after TAVI by echocardiography and by video-densitometric analysis of aortograms. Contrast time-density curves for the aortic root (the reference region) and the left ventricular outflow tract, LVOT were generated. LVOT-AR was calculated as the area under the curve of the LVOT as a fraction of the area under the curve of the reference region. RESULTS: LVOT-AR was 0.10 ± 0.08, 0.13 ± 0.10 and 0.28 ± 0.14 in none-trace, mild and moderate-severe post-TAVI AR as defined by echocardiography (P < 0.001) and a cutpoint of >0.17 corresponded to moderate-severe AR on echocardiography (area under the curve = 0.84). At follow-up (median, 496 days), patients with LVOT-AR ≤ 0.17 showed a significant reduction of LV mass index (LVMi; 121 [95-148] vs. 140 [112-169] g/m2 , P = 0.009) and the prevalence of LV hypertrophy (LVH; 64 vs. 88%, P = 0.001) compared to baseline. In patients with LVOT-AR > 0.17, LVMi (149 [121-178] vs. 166 [144-188] g/m2 , P = 0.14) and the prevalence of LVH (74 vs. 87%, P = 0.23) did not show a significant change. Compared to patients with LVOT-AR ≤ 0.17, those with LVOT-AR > 0.17 had an increased 30-day (16.4% vs. 7.1%, P = 0.035) and one year mortality (32.9 vs. 14.2%, log rank P value = 0.001; HR: 2.690 [1.461-4.953], P = 0.001). CONCLUSIONS: LVOT-AR > 0.17 corresponds to greater than mild AR as defined by echocardiography and predicts impaired LV reverse remodeling and increased early and midterm mortality after TAVI. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Aortografía/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Área Bajo la Curva , Brasil , Densitometría , Ecocardiografía Doppler en Color , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Curva ROC , Sistema de Registros , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA